◇ MAIN COMPONENTS
1. Compressor
2. Overload protector
3. Run capacitor
4. Condenser fan motor

◇ WIRING DIAGRAM

◇ POWER INPUT/OUTPUT

◇ CONDENSER COIL

◇ PART NAME

◇ SAK-50*, SAK-60*, SAK-70*, (SVC PART LIST)


MAIN COMPONENTS

1. Compressor
Manufacturer SAMSUNG KWANGJU ELECTRONICS CO LTD
Designation SD152C-L1U
Electrical Rating
V, Hz, Phase 115 V, 60 Hz, 1 Ph
RLA(+) 1.29/1.92 A
LRA 9.4/9.6 A

2. Overload Protector
Manufacturer Texas Instruments
Model or Designation 4TM412PFBYY

3. Run Capacitor
Rating, uF, V 12 uF, 250 V
Rating, uF, V 000 uF, 250 V

4. Condenser Fan Motor


Manufacturer FULLTECH ELECTORIC CO LTD
Model UF-12A11
Rating V, Hz, Phase, A or W 115 V, 60 Hz, 1 Ph, 12 W
WIRING DIAGRAM
POWER INPUT/OUTPUT
a. After installing unit and all electrical to the Display, Display is ready to start up.
b. Power input is controlled by pushing the button.

iii Apporx 30min interval is needed to reactivate display case after power off.

SPECIFICATION
Model SAK-50* SAK-60* SAK-70*
Dimension 48.8×14.2×11.5 60.3×14.2×11.5 71.8×14.2×11.5
(W×D×H) in
Electricity 120V/1Ph/60Hz
Power Input 3A 3A 3A
Compressor SD152C-L1U2
Refrigerant R-134a
Weight of Case 76.06lbs 87.08lbs 98.10lbs

LOCATION OF DISPLAY CASE


MERCHANDISER
Display is designed to be in an ambient 75 degrees Fahrenheit (dry bulb) or colder and 55 percent relative humidity. If unit is
installed in a warm ambient Display will not cool effectively. Move the display to the final location before removing shipping skid.
Allow 3 inches from back of Display to wall. Condenser is located in beside of Display. Do not block inlet /outlet.

CONDENSER COIL

③ ①

1. Disconnect the electrical power to the unit


2. Lift up the Louver to release the Louver from the body.(①)
3. Pull the Louver toward you.(②)
4. Pull on the downward. (③)
5. Brush the dirt, lint, etc from the finned condenser coil.
6. When finished, Louver installed by reverse way of removing
7. Reconnect the electrical power to the unit.
8. Condenser should be cleaned every 1 months or as needed.
PART NAME Side cover R
ABS
Top cover
SUS 304 0.7T

Side cover L
ABS

C.D.U. cover
SUS 304 0.7T

Front cover
SUS 304 0.7T

Front glass

Condenser cover
SUS 304 0.7T

Power switch

Door molding Door handle


ABS ABS

Door glass
GLASS

Door set Thermometer


Top cover
SUS 394 Side cover R
ABS

Top cover base


ABS

Side cover L
ABS

Front cover
SUS 304 0.7T

Side cover bracket R


GI 0.8T

Condenser cover
Condenser filter
SUS 304 0.7T

Door post
ABS
Drain cap
PE
Drain pipe
PVC
Evaporator Evaporator cover
SUS 304 0.7T

Bottom shelf
SUS 304 0.8T
Drain cap
PE
Capillary tube
Condenser D: 2mm
L : 2400mm

Condenser fan motor

Compressor

Urethane form case


Drain hole
ABS

Urethane form base


GI 1T
Thermometer

Drier
PART LIST

SAK-50. SAK-60. SAK-70. PART LIST

Part name SAK-50 SAK-60 SAK-70 비 고

1 Bottom shelf 3 5 5 SUS-304 0.8T


2 C.D.U. cover 1 1 1 SUS-304 0.7T
3 Capillary tube 1 1 1 CU
4 Compressor 1 1 1 SAMSUNG SD-152C-L1U
5 Condenser 1 1 1 CU + AL
6 Condenser cover 1 1 1 SUS-304 0.7T
7 Condenser fan motor 1 1 1 UF-12A11
8 Condenser filter 1 1 1
9 Door glass 2 4 4 Glass 3.2T
10 Door handle 2 4 4 ABS
11 Door molding 2 4 4 ABS
12 Door post 3 4 4 ABS
13 Drain cap 2 2 2 PE
14 Drier 1 1 1 Cu ,1/4
15 Evaporator 1 1 1 CU + AL
16 Evaporator cover 1 1 1 SUS-304 0.7T
17 Front cover 1 1 1 SUS-304 0.7T
18 Front glass 1 1 1 Glass 5T
19 Over load protector 1 1 1 4TM412PFBYY
20 Power switch 1 1 1 KPB25AT
21 Run capacitor 1 1 1 12uF 250V
22 Side cover bracket L,R 1 1 1 GI 0.8T
23 Side cover L 1 1 1 ABS
24 Side cover R 1 1 1 ABS
25 Start Relay 1 1 1 JAHWA 6R8M
26 Thermometer 1 1 1 MILJOCO CORP B9-122
27 Top cover 1 1 1 SUS-304 0.7T
28 Top cover base 1 1 1 ABS
29 Urethane form base 1 1 1 GI 1T
30 Urethane form case 1 1 1 ABS + Urethane form