10 April 2010

Subject: Summary of Electro-Magnetic Compatibility (EMC) Test Results for


10GBASE-T with SYSTIMAX GigaSPEED™ X10D UTP Cabling

1. Introduction

As part of the SYSTIMAX 20 Year Extended Application Assurance Program, compliance to


the relevant EMC regulations has been included since the European Electromagnetic
Compatibility (EMC) Directive 89/336/EEC was introduced in 1996. The Application
Assurance was initially offered for all LAN applications up to IEEE 802.3ab 1000BASE-T,
and was extended to include 10GBASE-T operating over GigaSPEED X10D (CAT6A) when
the 802.3an standard was completed in 2006.

Several industry-leading equipment vendors have recently announced 10GBASE-T server


adapters and switches based on the latest 10GBASE-T transceiver technology. These
systems comply with the relevant IEC CISPR EMC requirements, and also state that they
will operate over Cat6A UTP cabling to 100 meters.

To further validate the EMC performance claim over Cat6A UTP cabling, CommScope
successfully completed comprehensive EMC testing of a 10GBASE-T system operating over
GigaSPEED X10D UTP cabling at an independent laboratory.

2. EMC Tests and Results

The EMC testing was performed at a National Technical Systems (NTS) Laboratory in
March 2010. NTS is a fully accredited independent EMC laboratory which had the following
accreditations at the time of testing:

• ISO/IEC 17025:2005 (General Requirements for the Competence of Testing and


Calibration Laboratories)
• ISO 9000: 1997 (E)
• A2LA, VCCI, BSMI
• Semi-anechoic chamber accepted by FCC
• Compliance with radiated and AC line conducted test site criteria in ANSI C.63.4-
2005 as required by the FCC

Page 1
The following EMC tests were carried out:

a) Radiated Emission according to IEC CISPR 22 or EN 55022


b) Radiated Field Immunity according to IEC CISPR 24 or EN 55024 and IEC 61000-4-3
c) Electrical Fast Transients/Burst Immunity according to IEC CISPR 24 or EN 55024 and
IEC 61000-4-4
d) Conducted Immunity according to IEC CISPR 24 or EN 55024 and IEC 61000-4-6
e) Electrostatic Discharge (ESD) according to IEC CISPR 24 or EN 55024 and IEC
61000-4-2

Table 1 provides a list of the equipment used in the testing. The test configuration is
according to ISO/IEC JTC1 SC25 WG3 3N447B - Evaluation of proposed generic cabling
set-up to be included in EMC testing of information technology equipment based on radiated
emission tests, by Erik Bech, 14th March 1997. See Figure 1.

Equipment List
Dell PowerEdge 2950 servers
Intel PRO/10GBE 10GBASE-T server adapter NICs

Table 1: Equipment used in the EMC testing

Table 2 provides a summary of the EMC test results. As indicated below, passing results
were achieved on each of the EMC tests.

Summary of EMC Test Results for 10Gb/s IEEE 802.3an 10GBASE-T with
GigaSPEED X10D UTP cabling solution
Tests Limits Results
Radiated Emissions Class A
Pass
IEC CISPR 22, EN 55022 30 MHz to 1 GHz

ESD Immunity Contact Discharge: 4 kV


Pass
IEC 61000-4-2 Air Discharge: 8 kV

Radiated Immunity 3 V/m


Pass
IEC 61000-4-3 30 MHz to 1 GHz
EFT/Burst Immunity
IEC 61000-4-4 500 V Pass
Signal/Control Lines
Conducted Immunity 3 Vrms
Pass
IEC 61000-4-6 0.15 MHz to 80 MHz

Table 2: Summary of EMC Test Results for IEEE 802.3an 10GBASE-T with GigaSPEED
X10D UTP cabling solution

Page 2
An excerpt from NTS EMC Test Report for GigaSPEED X10D UTP Cabling which
summarises the test results is shown in Figure 2.

Annex A contains details of the Radiated Emissions test results, while Annex B contains
images of each of the test set-ups.

Figure 1: EMC Test Configuration according to ISO/IEC JTC1 SC25 WG3 3N447B

Page 3
Figure 2: Excerpt from NTS EMC Test Report for GigaSPEED X10D UTP Cabling

Page 4
ANNEX A

Detailed Test Results

Page 5
CISPR A Limit Class A Limit @
Scan
3 m distance
Peak (dB)

Figure A.1: Radiated Emissions 30 – 1000 MHz Horizontal

CISPR A Limit
Scan
Class A Limit @
Peak (dB) 3 m distance

Figure A.2: Radiated Emissions 30 – 1000 MHz Vertical

Page 6
ANNEX B

Test Setups

Page 7
Figure B.1: Radiated Emission Test Setup

Radiated Emissions (Chamber) 30 MHz – 1000MHz (EN55022)

Page 8
Figure B.2: Radiated Immunity Test Setup

Radiated Immunity 30 MHz – 1000 MHz (EN61000-4-3)

Page 9
Figure B.3: Conducted Susceptibility Test Setup

Conducted Susceptibility Test Set Up (EN61000-4-6)

Page 10
Figure B.4: Electro-Static Discharge (ESD) Test Setup

(a) ESD Test Set-Up for Air Discharge (8 kV) (EN61000-4-2)

(b) ESD Test Set-Up for Direct Discharge (4 kV) (EN61000-4-2)


Page 11
Figure B.5: Electrical Fast Transient Test Setup

EFT/Burst Test Set Up (EN61000-4-4)

Page 12