You are on page 1of 4

TURCK flow sensors and modules

combination possibilities

Flow-
Flow sensors
modules
Type code Ex area Medium Housing
Connection type Connection type
Cable M12 x 1

gaseous
INTELLIGENT

immer-
zone 0

zone 1

liquid

inline
sion
SIGNAL FCS-…-NA

FCS-…-NA-H1141


PROCESSORS
 
 

 
 


FOR
 





FCS-…-NA/A FCS-…-NA-H1141/A
FLOW SENSORS 







 
  FM-IM
   

 
104
89

FCI-…-NA-H1141





  110

27





FCI-…P-NA



 



FCI-…P-NA-H1141




 








FCS-…-NAEX


FCS-…-NAEX-H1141



www.turck.com


  

 
 




FCS-…-NAEX/A FCS-…-NAEX-H1141/A
 
 


  


 

  

 

FCI-…-NAEX-H1141 FMX-IM





  
104
89
To get all product

 information, just
 scan the QR code
110 with a smart-
FCS-…-NAEX0 FCS-…-NAEX0-H1141 27
phone or webcam

 
 


   Hans Turck GmbH & Co. KG



 

 Witzlebenstraße 7



 45472 Mülheim an der Ruhr
FCS-…-NAEX0/A FCS-…-NAEX0-H1141/A Germany



 Tel. +49 208 4952-0
 Fax +49 208 4952-264
  




 


 
E-Mail more@turck.com
  Internet www.turck.com

D101879 0812

Sense it! Connect it! Bus it! Solve it! *D101879ßß0812*


The new generation of flow modules FM/FMX
Intelligent signal processors for flow sensors

Signal processors with


diagnostic functions and
IO-Link/HART® interface
The new flow modules of the FM-IM series The modules are available in the approved Thanks to its multifunctionality, the FM-IM
combine easy handling and high func- IM DIN rail design and are easily configured series is easily integrated in any automa-
tionality with many connection possibi- either via pushbutton or via IO-Link /HART® tion system. There are many application
lites, adapted to the latest requirements. interface. The user can adjust the switch- possibilites, such as run-dry protection of
point with the innovative quick-teach pumps or monitoring of coolant circuits
All TURCK flow sensors of the FCS (immer- function. and inerting systems.
sion) and FCI (inline) series can be oper-
ated at the new modules. The sensors Not only wire-break, short-circuit or the
working on the calorimeric principle, de- operating range are monitored, the diag-
tect the flow speed as well as the media nostic results are also indicated via LED
temperature continuously. and a 10-segment LED band, if required.

Overview of flow modules


Dimension drawing Type code 20…30 VDC 20…125 DC/ Flow Temperature Fault signal IO-Link HART®
20…250VAC (Out 1) (Out 2) (Out3)
FM-IM-3UP63X  COM (PC), Out 1 –

FM-IM-3UR38X  COM (PC) –

FM-IM-2UPLi63X  COM (PC), –


Clamp 12

FMX-IM-3UP63X  COM (PC), Out 1 –

FMX-IM-3UR38X  COM (PC) –

FMX-IM-2UPLi63X  – COM (PC),


Out 1

High functionality Simple configuration Large variety of device types Comprehensive display and diagnostics of values
No complicated adjustments of The flow modules feature The FM series features six devices. The user can choose between lo-
upper and lower limit values. two operating modes: The SIO Three devices for the connection cal as well as different remote di-
Switchpoints, flow and tem- mode(standard IO) for convention- of non-Ex area sensors (FM) and agnostic functions. For example,
perature ranges are easily set up, al switching and the IOL mode (IO- three for Ex area sensors (FMX). wire-break, short-circuit, monitor-
thanks to the quick-teach func- Link), transmitting current 12 bit They are equipped with standard ing of the operating range and
tion and the intuitive menu navi- process value. The flow modules are PNP transistor outputs, relay out- display of flow speed and media
gation. either configured via pushbuttons puts as well as analog 4…20 mA temperature.
or remotely via the IO-Link/HART® current outputs.
communication interface.
The new generation of flow modules FM/FMX
Intelligent signal processors for flow sensors

Signal processors with


diagnostic functions and
IO-Link/HART® interface
The new flow modules of the FM-IM series The modules are available in the approved Thanks to its multifunctionality, the FM-IM
combine easy handling and high func- IM DIN rail design and are easily configured series is easily integrated in any automa-
tionality with many connection possibi- either via pushbutton or via IO-Link /HART® tion system. There are many application
lites, adapted to the latest requirements. interface. The user can adjust the switch- possibilites, such as run-dry protection of
point with the innovative quick-teach pumps or monitoring of coolant circuits
All TURCK flow sensors of the FCS (immer- function. and inerting systems.
sion) and FCI (inline) series can be oper-
ated at the new modules. The sensors Not only wire-break, short-circuit or the
working on the calorimeric principle, de- operating range are monitored, the diag-
tect the flow speed as well as the media nostic results are also indicated via LED
temperature continuously. and a 10-segment LED band, if required.

Overview of flow modules


Dimension drawing Type code 20…30 VDC 20…125 DC/ Flow Temperature Fault signal IO-Link HART®
20…250VAC (Out 1) (Out 2) (Out3)
FM-IM-3UP63X  COM (PC), Out 1 –

FM-IM-3UR38X  COM (PC) –

FM-IM-2UPLi63X  COM (PC), –


Clamp 12

FMX-IM-3UP63X  COM (PC), Out 1 –

FMX-IM-3UR38X  COM (PC) –

FMX-IM-2UPLi63X  – COM (PC),


Out 1

High functionality Simple configuration Large variety of device types Comprehensive display and diagnostics of values
No complicated adjustments of The flow modules feature The FM series features six devices. The user can choose between lo-
upper and lower limit values. two operating modes: The SIO Three devices for the connection cal as well as different remote di-
Switchpoints, flow and tem- mode(standard IO) for convention- of non-Ex area sensors (FM) and agnostic functions. For example,
perature ranges are easily set up, al switching and the IOL mode (IO- three for Ex area sensors (FMX). wire-break, short-circuit, monitor-
thanks to the quick-teach func- Link), transmitting current 12 bit They are equipped with standard ing of the operating range and
tion and the intuitive menu navi- process value. The flow modules are PNP transistor outputs, relay out- display of flow speed and media
gation. either configured via pushbuttons puts as well as analog 4…20 mA temperature.
or remotely via the IO-Link/HART® current outputs.
communication interface.
TURCK flow sensors and modules
combination possibilities

Flow-
Flow sensors
modules
Type code Ex area Medium Housing
Connection type Connection type
Cable M12 x 1

gaseous
INTELLIGENT

immer-
zone 0

zone 1

liquid

inline
sion
SIGNAL FCS-…-NA

FCS-…-NA-H1141


PROCESSORS
 
 

 
 


FOR
 





FCS-…-NA/A FCS-…-NA-H1141/A
FLOW SENSORS 







 
  FM-IM
   

 
104
89

FCI-…-NA-H1141





  110

27





FCI-…P-NA



 



FCI-…P-NA-H1141




 








FCS-…-NAEX


FCS-…-NAEX-H1141



www.turck.com


  

 
 




FCS-…-NAEX/A FCS-…-NAEX-H1141/A
 
 


  


 

  

 

FCI-…-NAEX-H1141 FMX-IM





  
104
89
To get all product

 information, just
 scan the QR code
110 with a smart-
FCS-…-NAEX0 FCS-…-NAEX0-H1141 27
phone or webcam

 
 


   Hans Turck GmbH & Co. KG



 

 Witzlebenstraße 7



 45472 Mülheim an der Ruhr
FCS-…-NAEX0/A FCS-…-NAEX0-H1141/A Germany



 Tel. +49 208 4952-0
 Fax +49 208 4952-264
  




 


 
E-Mail more@turck.com
  Internet www.turck.com

D101879 0812

Sense it! Connect it! Bus it! Solve it! *D101879ßß0812*

You might also like