You are on page 1of 1

ROOF DECK

RD938 Limit States


Design

Metric

Base Steel Nominal Moment of Factored Resistance


Mass with Section Modulus
PHYSICAL Nominal Thickness Inertia Moment Reaction
Coating
PROPERTIES Thickness Z275 Coating Midspan Support Midspan Midspan Support Ext. Int.
(mm) (mm) (kg/m2) 3
x 10 (mm )
3 3
x 10 (mm )
3 3
x 10 (mm )
4
(Nm) (Nm) (kN) (kN) Notes
1 Properties and
(PER METRE WIDTH) 0.76 0.80 8.60 9.59 9.76 213.9 1985.1 2020.3 10.9 15.7
loads are based on
In accordance with CSA
0.91 0.95 10.17 11.70 12.31 266.8 2421.9 2548.2 15.3 22.3 Grade 230 Steel
Specification S136-01
with a minimum
1.22 1.26 13.34 15.87 16.21 363.9 3285.1 3355.5 25.8 38.4 yield stress of 230
1.52 1.56 16.45 20.00 20.06 454.3 4140.0 4152.4 38.9 58.7 MPa, and a
maximum stress
0.00 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.0 0.0 under Factored
loads of 207 MPa.
0.00 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.0 0.0

LOAD Support 1-Span 2-Span 3-Span 2 Row B indicates


Spacing the load capacity
TABLE (mm) 0.76 0.91 1.22 1.52 0.00 0.00 0.76 0.91 1.22 1.52 0.00 0.00 0.76 0.91 1.22 1.52 0.00 0.00 based on strength.
Maximum Specified Strength capacity
B 10.6 12.9 17.5 22.1 8.4 11.9 17.9 22.1 9.5 13.5 22.4 27.7
Uniformly Distributed 1000 should be checked
Load in kN/m2 (kPa) D 13.9 17.3 23.6 29.5 34.8 43.4 59.2 73.9 26.2 32.7 44.6 55.7 against [Specified
Live Load] +[0.833
B 8.0 9.8 13.2 16.7 7.3 10.3 13.5 16.7 8.3 11.8 16.9 20.9 x Specified Dead
1150
D Load]
9.1 11.4 15.5 19.4 22.9 28.5 38.9 48.6 17.2 21.5 29.3 36.6
B 3 Row D indicates
6.3 7.6 10.4 13.1 6.4 8.0 10.6 13.1 7.3 10.1 13.2 16.4
1300 the load capacity
D 63
6.3 7.9
79 10.8
10 8 13.4
13 4 15.8
15 8 19.8
19 8 26.9
26 9 33.6
33 6 11.9
11 9 14.9
14 9 20.3
20 3 25.3
25 3 based on a
deflection of
B 5.0 6.1 8.3 10.5 5.1 6.5 8.5 10.5 6.4 8.1 10.6 13.2
1450 1/240th span. For
D 4.6 5.7 7.8 9.7 11.4 14.2 19.4 24.2 8.6 10.7 14.6 18.3 allowable deflection
of 1/120th span,
B 4.1 5.0 6.8 8.6 4.2 5.3 7.0 8.7 5.3 6.6 8.7 10.8 values in Row D
1600
D can be doubled,
3.4 4.2 5.8 7.2 8.5 10.6 14.5 18.0 6.4 8.0 10.9 13.6
but must not
B 3.5 4.2 5.7 7.2 3.5 4.4 5.8 7.2 4.4 5.5 7.3 9.0 exceed the value in
1750
D Row B.
2.6 3.2 4.4 5.5 6.5 8.1 11.0 13.8 4.9 6.1 8.3 10.4
B 2.9 3.6 4.9 6.1 3.0 3.8 5.0 6.1 3.7 4.7 6.2 7.7 4 A highlighted value
1900
D indicates capacity
2.0 2.5 3.4 4.3 5.1 6.3 8.6 10.8 3.8 4.8 6.5 8.1
has been reduced
B 2.5 3.1 4.2 5.3 2.6 3.2 4.3 5.3 3.2 4.0 5.3 6.6 to account for web
2050 crippling.
D 1.6 2.0 2.7 3.4 4.0 5.0 6.9 8.6 3.0 3.8 5.2 6.5
B 2.2 2.7 3.6 4.6 2.2 2.8 3.7 4.6 2.8 3.5 4.6 5.7
2200
D 1.3 1.6 2.2 2.8 3.3 4.1 5.6 6.9 2.5 3.1 4.2 5.2
B 1.9 2.3 3.2 4.0 2.0 2.5 3.2 4.0 2.4 3.1 4.1 5.0
2350
D 1.1 1.3 1.8 2.3 2.7 3.3 4.6 5.7 2.0 2.5 3.4 4.3
B 1.7 2.1 2.8 3.5 1.7 2.2 2.9 3.5 2.2 2.7 3.6 4.4
2500
D 0.9 1.1 1.5 1.9 2.2 2.8 3.8 4.7 1.7 2.1 2.9 3.6
B 1.5 1.8 2.5 3.1 1.5 1.9 2.5 3.2 1.9 2.4 3.2 3.9
2650
D 0.7 0.9 1.3 1.6 1.9 2.3 3.2 4.0 1.4 1.8 2.4 3.0
B 1.4 1.6 2.2 2.8 1.4 1.7 2.3 2.8 1.7 2.2 2.9 3.5
2800
D 0.6 0.8 1.1 1.3 1.6 2.0 2.7 3.4 1.2 1.5 2.0 2.5
B 1.2 1.5 2.0 2.5 1.2 1.6 2.1 2.5 1.5 2.0 2.6 3.2
2950
D 0.5 0.7 0.9 1.1 1.4 1.7 2.3 2.9 1.0 1.3 1.7 2.2
B 1.1 1.3 1.8 2.3 1.1 1.4 1.9 2.3 1.4 1.8 2.3 2.9
3100
D 0.5 0.6 0.8 1.0 1.2 1.5 2.0 2.5 0.9 1.1 1.5 1.9

1. Deflection values are based upon service loads.


2. Denotes web crippling governs.

© Copyright VICWEST R-4/01