Professional Documents
Culture Documents
Ciat Price List 31 05 17
Ciat Price List 31 05 17
Together our vision is to be the UK’s No. 1 supplier of technologically innovative, energy-efficient, environmentally-friendly
HVAC equipment, combined with a first class level of customer support.
We offer our customers full support from our engineers to back our supply of exceptional products. From design and
specification, through installation and commissioning, control integration and maintenance we work with you to form a
real partnership.
The new CIAT Centre of Excellence includes two research and development facilities and test laboratories, which focus on
product innovation to shorten new product development time scales and improve energy performance and user comfort.
The R&D investment is part of more than $40m that UTC has invested at Culoz and Montluel, since the acquisition in 2015.
The factory in Montluel houses a Centre of Excellence for chillers and heat pumps. It supports chiller innovation and
production, with a focus on new generation, environmentally-responsible refrigerants, with Culoz supporting further
development of the new AHU range introduced during 2016.
The strategic move allows us to strengthen our heating, ventilating and air conditioning range, as well as our competitiveness
and ability to innovate. The significant investment in the Culoz and Montluel sites complement each other and support
production and design, allowing further improvement of our products and our ability to serve our customers.
Accessories
Description Part Number Price, £
Wired remote control for LC range - KJR-12- G2 7511630 73
Centralised wired remote control for LC range connectable up to 64 units - CCM-30 7511631 364
MAMBO
Universal air conditioner
Inverter - R410A
Model MAMBO MAMBO MAMBO
Ceiling 48HV Ceiling 48HVT Ceiling 60HVT
Indoor unit 42HU48VSC 42HU48VSC 42HU60VSC
Outdoor unit 38HU48VSC 38HU48VTC 38HU60VTC
Cooling capacity Min./nom./max. kW 4.80/13.60/14.00 4.80/13.60/14.00 5.40/15.50/16.00
Heating capacity* Min./nom./max. kW 5.40/15.50/16.00 5.40/15.50/16.00 4.30/17.50/18.50
@ -7°C kW 11.30 11.10 11.50
@ -10°C kW 10.80 10.50 11.10
@ -15°C kW 9.40 8.60 9.90
P design capacity cooling kW 13.60 13.60 15.50
P design capacity heating Warmer/average kW 10.60/11.90 11.30/12.10 11.80/11.60
Temperature range Cooling °C -10~46 -10~46 -10~46
Heating °C -15~24 -15~24 -15~24
SEER W/W 5.9 5.8 5.8
SCOP Warmer/average W/W 4.0/5.3 4.0/5.3 4.1/5.1
Energy label SEER A+ A+ A+
SCOP warmer/average A+/A+++ A+/A+++ A+/A+++
Yearly energy consumption kWh 810/3718/3167 815/3954/3179 938/4011/3173
EER/COP W/W 2.4/2.9 2.4/3.0 2.5/3.1
Rated current A 26.5 13 14
Rated input kW 6.10 6.10 7.50
Power supply V/ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50
Refrigerant amount R410A kg 4.00 4.00 4.30
Liquid side - gas side inch 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8
Standard piping length Min./max. piping length m 3/50 3/50 3/50
Max. height difference m 25 25 25
Additional charge g/m 30 30 30
Indoor unit 42HU48VSC 42HU48VTC 42HU60VTC
Sound power level** dB(A) 69 69 73
Sound pressure level** High/med./low dB(A) 55/51/46 55/51/46 56/51/47
Air flow High/med./low m3/h 2100/1700/1500 2100/1700/1500 2250/1900/1500
Weight kg 38.2/44.6 38.2/44.6 40.5/47
Dimension WxDxH mm 1650 x 675 x 235 1650 x 675 x 235 1650 x 675 x 235
Outdoor unit 38HU48VSC 38HU48VTC 38HU60VTC
Sound power level** dB(A) 75 75 77
Sound pressure level** dB(A) 64 64 64
Air flow m3/h 6800 6800 7000
Weight kg 95.1/108.4 108.1/121.2 112.8/126
Dimension WxDxH mm 952 x 415 x 1333 952 x 415 x 1333 952 x 415 x 1333
System retail price £ 2,631 2,660 2,728
* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode
Accessories
Description Part Number Price, £
Wired remote control for LC range - KJR-12- G2 7511630 73
Centralised wired remote control for LC range connectable up to 64 units - CCM-30 7511631 364
Accessories
Description Part Number Price, £
Wired remote control for high-wall units - KJR-12- G1 7511629 68
Wi-Fi USB for hung wall range - WIFI USB 7511628 17
Accessories
Description Part Number Price, £
Wired remote control for LC range - KJR-12- G2 7511630 73
Centralised wired remote control for LC range connectable up to 64 units - CCM-30 7511631 364
10
SALSA
Cassette air conditioner
Inverter - R410A
Model SALSA 36HVT SALSA 48HV SALSA 48HVT SALSA 60HV
Indoor unit 42HK36VSC 42HK48VSC 42HK48VSC 42HK60VSC
Indoor unit panel 40CAS-L9 40CAS-L9 40CAS-L9 40CAS-L9
Outdoor unit 38HU36VTC 38HU48VSC 38HU48VTC 38HU60VTC
Cooling capacity Min./nom./max. kW 3.80/10.20/11.50 4.80/13.40/14.00 4.80/13.40/14.00 5.00/15.10/16.00
Heating capacity* Min./nom./max. kW 2.90/11.30/13.80 5.40/15.50/16.00 5.40/15.50/16.00 3.90/18.00/18.20
@ -7°C kW 9.60 10.40 10.50 12.20
@ -10°C kW 8.20 9.90 10.00 11.90
@ -15°C kW 8.10 8.40 8.50 9.80
P design capacity cooling kW 10.20 13.40 13.40 15.10
P design capacity heating Warmer/average kW 9.60/10.20 10.70/11.80 11.00/11.80 11.20/12.10
Temperature range Cooling °C -10~46 -10~46 -10~46 -10~46
Heating °C -15~24 -15~24 -15~24 -15~24
SEER W/W 5.9 5.5 5.6 5.7
SCOP Warmer/average W/W 4.0/5.0 4.0/5.0 4.0/5.1 4.0/5.2
Energy label SEER A+ A A+ A+
SCOP warmer/average A+/A++ A+/A++ A+/A+++ A+/A+++
Yearly energy consumption kWh 610/3360/2885 852/3756/3323 834/3847/3231 929/3916/3225
EER/COP W/W 2.6/3.4 2.4/2.9 2.5/3.0 2.4/3.1
Rated current A 12 26.5 13 14
Rated input kW 4.80 6.10 6.10 7.50
Power supply V/ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50
Refrigerant amount R410A kg 3.65 4.00 4.00 4.30
Liquid side - gas side inch 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8
Standard piping length Min./max. piping length m 3/50 3/50 3/50 3/50
Max. height difference m 25 25 25 25
Additional charge g/m 30 30 30 30
Indoor unit 42HK36VSC 42HK48VSC 42HK48VSC 42HK60VTC
Sound power level** dB(A) 65 67 67 70
Sound pressure level** High/med./low dB(A) 53/51/48 51/49/47 51/49/47 54/52/49
Air flow High/med./low m3/h 1800/1600/1400 1900/1600/1330 1900/1600/1330 2000/1780/1580
Weight Body kg 27.5/31.5 28/32,1 28/32,1 31.0/34.0
Panel kg 5.0/8.0 5.0/8.0 5.0/8.0 5.0/8.0
Dimension Body W x D x H mm 840 x 840 x 245 840 x 840 x 245 840 x 840 x 245 840 x 840 x 245
Panel W x D x H mm 950 x 950 x 55 950 x 950 x 55 950 x 950 x 55 950 x 950 x 55
Outdoor unit 38HU36VTC 38HU48VSC 38HU48VTC 38HU60VTC
Sound power level** dB(A) 70 75 75 77
Sound pressure level** dB(A) 64 64 64 64
Air flow m3/h 4150 6800 6800 7000
Weight kg 85.3/91.0 95.1/108.4 108.1/121.2 112.8/126.0
Dimension WxDxH mm 946 x 410 x 810 952 x 415 x 1333 952 x 415 x 1333 952 x 415 x 1333
System retail price £ 2,332 2,611 2,641 2,764
* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode
11
Accessories
Description Part Number Price, £
Wired remote control for LC range - KJR-12- G2 7511630 73
Centralised wired remote control for LC range connectable up to 64 units - CCM-30 7511631 364
12
TWIST
Ducted air conditioner
Inverter - R410A
Model TWIST 36HVT TWIST 48HV TWIST 48HVT TWIST 60HV
Indoor unit 42HY36VSC 42HY48VSC 42HY48VSC 42HY60VSC
Outdoor unit 38HU36VTC 38HU48VSC 38HU48VTC 38HU60VTC
Cooling capacity Min./nom./max. kW 3.60/10.20/11.00 5.10/13.70/14.40 4.90/13.70/14.20 5.20/15.40/16.00
Heating capacity* Min./nom./max. kW 2.70/12.70/13.50 4.40/15.40/16.40 4.70/15.40/16.90 4.80/17.60/18.80
@ -7°C kW 9.90 10.80 11.60 12.60
@ -10°C kW 9.10 10.30 10.70 11.80
@ -15°C kW 8.10 8.90 9.10 10.20
P design capacity cooling kW 10.20 13.70 13.70 15.40
P design capacity heating Warmer/average kW 10.00/10.30 10.30/11.60 11.50/12.40 12.00/12.20
Temperature range Cooling °C -10~46 -10~46 -10~46 -10~46
Heating °C -15~24 -15~24 -15~24 -15~24
SEER W/W 6.2 5.8 5.9 5.5
SCOP Warmer/average W/W 4.0/5.0 4.0/4.9 4.0/5.4 4.0/5.1
Energy label SEER A++ A+ A+ A
SCOP warmer/average A+/A++ A+/A++ A+/A+++ A+/A+++
Yearly energy consumption kWh 577/3481/2912 826/3597/3337 813/4030/3206 963/4196/3328
EER/COP W/W 2.6/3.7 2.7/3.5 2.6/3.7 2.3/3.4
Rated current A 12 26.5 13 14
Rated input kW 4.80 6.10 6.10 7.50
Power supply V/ph/Hz 380-415/3/50 220-240/1/50 380-415/3/50 380-415/3/50
Refrigerant amount R410A kg 3.65 4.00 4.00 4.30
Liquid side - gas side inch 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8
Standard piping length Min./max. piping length m 3/50 3/50 3/50 3/50
Max. height difference m 25 25 25 25
Additional charge g/m 30 30 30 30
Indoor unit 42HY36VSC 42HY48VSC 42HY48VSC 42HY60VTC
Sound power level** dB(A) 65 71 71 76
Sound pressure level** High/med./low dB(A) 47/45/43 53/51/49 53/51/49 58/56/54
Air flow High/med./low m3/h 1900/1550/1200 2400/2050/1750 2400/2050/1750 2500/2100/1800
Weight kg 40.5/48.5 46.0/55.0 46.0/55.0 46.0/55.0
Dimension WxDxH mm 1360 x 774 x 249 1200 x 874 x 300 1200 x 874 x 300 1200 x 874 x 300
Outdoor unit 38HU36VTC 38HU48VSC 38HU48VTC 38HU60VTC
Sound power level** dB(A) 70 75 75 77
Sound pressure level** dB(A) 64 64 64 64
Air flow m3/h 4150 6800 6800 7000
Weight kg 85.3/91.0 95.1/108.4 108.1/121.2 112.8/126
Dimension WxDxH mm 1090 x 500 x 875 952 x 415 x 1333 952 x 415 x 1333 952 x 415 x 1333
System retail price £ 2,497 2,706 2,735 2,813
* -7°C/-10°C/-15°C heating at free frequency ** Sound data in cooling mode
13
14
Stella high-wall
42HV09VSC 9k 2.7 £129
Salsa cassette
42HK09VSC 9k 2.6 £309
Twist ducted
42HY12VSC 12k 3.5 £394
15
Multi-split system
Note:
1. The capacity is tested with standard 9K indoor unit as below:
18K condensing unit + 2 x 9K indoor units
27K condensing unit + 3 x 9K indoor units
36K condensing unit + 4 x 9K indoor units
42K condensing unit + 5 x 9K indoor units
2. 18K indoor units should apply 1/2” gas pipe with one additional adapter 3/8’’-1/2” required in condensing unit.
3. 24K indoor units should apply 3/8” liquid pipe with one additional adapter 1/4’’-3/8” required in indoor units, and apply 5/8” gas pipe with one
additional adapter 1/2’’-5/8” in condensing unit.
16
Accessories
Description Sizes 4H-15H/HT Price, £ Sizes 17H/HT–21HT Price, £
Screen filter valve kit 7166295 73 Included -
Charging kit/1-1/4 filling kit 7013876 82 7013877 95
50 l 4-nozzle mixing tank 7328746 335 - -
100 l 8-nozzle mixing tank 7328744 421 7328744 421
200 l 8-nozzle mixing tank 7328747 730 7328747 730
DUO hydraulic module 3911008 1,397 3911008 1,397
5 kW single-phase loop heater (only available for sizes 4H-15H) 7148641 761 - -
9 kW three-phase loop heater (only available for sizes 12HT-21HT) 7148642 924 7148642 924
9 kW back-up heater for mounting in 200 l tank - - 7221389 383
300 l DHW tank 7385910 1,195 7385910 1,195
3-way valve for DHW 300 l 7422270 299 7422270 299
DHW sensor & 3-way valve kit (required with 300 l DHW tank) - - 7411357 445
Underfloor heating/cooling system limiter thermostat 7422271 68 7274278 68
Sensor for 4 units operating in parallel – modular configuration - - 7484985 34
Outdoor sensor - - 7484983 30
Pool heating kit (sensor + 3-way valves) - - 7111122 445
ITEX exchanger pool+ Ti 24 - - 7268481 824
17
18
Condenser entering/leaving water temperature difference: 5 K (for leaving water temperatures below 50°C)
Condenser fluid: water
Fouling factor: 0.000018 m 2 K/W
19
Condenser entering/leaving water temperature difference: 5 K (for leaving water temperatures below 50°C)
Condenser fluid: water
Fouling factor: 0.000018 m 2 K/W
20
Accessories
Description Sizes 50H/HT-65HT Price, £ Sizes 90HT-120HT Price, £
Manual valve kit (2 x required) 7110726 73 7110727 88
Filling kit 7013877 92 7111810 109
GeoCooling kit 7438199 1,453 7438200 1,563
200 l 8-nozzle mixing tank 7328747 713 - -
400 l 8-nozzle mixing tank 7328748 957 7328748 957
9 kW aux heater kit to be integrated in the 8-nozzle mixing tanks 7221389 374 7221389 374
5 kW (single phase) loop heater 7148641 743 - -
9 kW (three phase) loop heater - - 7148642 902
2-zone kit (accelerator pump, 3-way valve, thermometers, HomeConnect 7438198 1,318 7438198 1,318
expansion board, wireless IO Homecontrol sensor)
HomeConnect expansion board 7438336 304 7438336 304
Pool heating kit (sensor + 3-way valves) 7111122 435 7111122 435
UFHC limiter thermostat (60°C) 7274278 68 7274278 68
300 l domestic hot water tank (sensor and 3-way valve) 7411502 1,602 - -
Outdoor sensor with radio signal (to replace the wired outdoor sensor) 7262090 92 7262090 92
Offset sensor (10 m) 7438175 147 7438175 147
Sectional heat exchanger ITEX AGEO (water-to-water operation) 7268481 824 7268481 824
21
22
23
24
Accessories
Description Part Number Price, £
1-1/2” flexible customer kit 7187605 147
SoftStart kit 7272062 290/650 (150Z)
Phase monitor kit (reversal, loss, over- and undervoltage) 7081668 201
1-1/2” filling kit* 7111810 101
Electrical auxiliary unit by 9 kW loop heater supplied separately 7148642 836
Electrical auxiliary unit by 15 kW loop heater supplied separately 7272405 994
Hydraulic control kit (pressure gauges, control & shut-off valve) 3911008 1,264
200 litre 8-nozzle mixing tank 7328747 661
400 litre 8-nozzle mixing tank 7328748 887
9 kW electrical auxiliary kit to be integrated into the 200 or 400 litre 8-nozzle mixing tank 7221389 347
Pool heating kit with motorised 3-way valves 7111122 403
DHW heating kit (2 x 300 litre tanks in parallel) and motorised 3-way valves 2 x 7385910 + 7411357 2,969
Safety hot water thermostat kit (60°C) 7101578 54
Frost protection 7090373 200
25
26
Part Number with AquaPack† 7490506-AP 7490507-AP 7490508-AP 7490509-AP 7490510-AP 7490511-AP
Price (chiller with AquaPack) £ 14,639 15,110 15,793 17,580 18,725 20,594
27
28
29
AQUACIAT heat pump model ILD0150A ILD0180A ILD0200A ILD0240A ILD0260A ILD0300A
Nominal cooling capacity* kW 38 43 50 59 64 74
EER/ESEER kW/kW 2.84/3.80 2.70/3.77 2.65/3.81 2.77/3.61 2.70/3.61 2.58/3.57
Eurovent class C1 C C D C C D
Nominal heating capacity** kW 42 47 53 61 70 78
COP/SCOP kW/kW 3.08/3.07 3.05/3.10 3.03/3.21 3.03/3.07 3.06/3.10 2.87/2.96
Eurovent class H1 B B B B B C
Sound power***/Sound pressure at 10 m**** dB(A) 80/49 81/49 81/49 86/55 87/55 87/55
Sound power extra low noise option*** dB(A) 79 80 80 80 80 80
Sound pressure at 10 m extra low noise option† dB(A) 48 48 48 48 48 48
Width x length mm 2109 x 1090 2109 x 1090 2109 x 1090 2109 x 1090 2109 x 1090 2109 x 1090
Height (with buffer tank) mm 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040)
Weight - standard unit kg 497 506 543 549 559 564
Compressors Scroll 2 2 2 2 2 2
Minimum output % 50 50 50 50 50 50
Maximum total air flow l/s 3692 3690 3910 5285 5284 5282
Part Number (heat pump only) 7490822 7490823 7490824 7490825 7490826 7490827
Total price (heat pump only)† £ 11,327 11,886 12,679 14,660 15,747 17,502
Part Number (heat pump with AquaPack)‡ 7490822-AP 7490823-AP 7490824-AP 7490825-AP 7490826-AP 7490827-AP
Total price (heat pump with AquaPack) £ 16,403 16,962 17,754 19,736 20,822 23,426
AQUACIAT heat pump model ILD0302A ILD0360A ILD0390A ILD0450A ILD0520A ILD0600A
Nominal cooling capacity* kW 78 86 96 113 132 149
EER/ESEER kW/kW 2.79/3.84 2.70/3.77 2.7/3.88 2.69/4.04 2.77/3.75 2.58/3.67
Eurovent class C1 C C C D C D
Nominal heating capacity** kW 80 93 101 117 138 158
COP/SCOP kW/kW 3.08/3.14 3.02/3.17 3.09/3.23 3.06/3.23 3.07/3.14 2.97/3.13
Eurovent class H1 B B B B B C
Sound power***/Sound pressure at 10 m**** dB(A) 84/52 84/52 84/52 84/52 90/58 90/58
Sound power extra low noise option*** dB(A) 83 83 83 83 83 83
Sound pressure at 10 m extra low noise option**** dB(A) 52 51 51 51 51 51
Width x length mm 2123 x 2270 2123 x 2270 2123 x 2270 2123 x 2270 2123 x 2270 2123 x 2270
Height (with buffer tank) mm 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040) 1440 (2040)
Weight - standard unit kg 777 896 905 979 1053 1057
Compressors Scroll 3 3 3 3 2+2 2+2
Minimum output % 33 33 33 33 25 25
Maximum total air flow l/s 7770 7380 7376 7818 10568 10568
Part Number (heat pump only) 7491009 7490828 7490829 7490830 7490831 7490832
Total price (heat pump only)† £ 18,350 20,082 21,891 24,876 28,058 31,583
Part Number (heat pump with AquaPack)‡ 7491009-AP 7490828-AP 7490829-AP 7490830-AP 7490831-AP 7490832-AP
Total price (heat pump with AquaPack) £ 24,416 26,148 27,957 30,842 34,193 37,717
* Cooling mode conditions: water inlet/outlet temperature 12°C/7°C, ambient 35°C.
** Heating mode conditions: water inlet/outlet temperature 30°C/35°C, ambient 7°C/6°C.
*** In dB ref = 10-12 W, ‘A’ weighted. Measured in accordance with ISO 9614-1.
**** In dB ref 20 uPa, ‘A’ weighted. For information, calculated from the sound power level Lw(A). Declared dual number noise emission values in
accordance with ISO 4871 (with an associated uncertainty of ±3 dB(A). Values are guidelines only. Refer to the unit name plate.
† Standard commissioning not included. Standard day’s commissionin will be charged at £620 per day. Terms apply.
‡ AquaPack includes: hydronic module116r, expansion tank 293, water buffer tank module 307, exchanger water filter 310A).
30
31
32
33
34
35
The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water
range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with
an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range
of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program.
For a list of products and certified characteristics, please refer to www.eurovent-certification.com.
36
4-way grille
Description Part Number Total price, £
360° suction/discharge grille with Epure filter 7335537 Included
The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water
range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with
an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range
of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program.
For a list of products and certified characteristics, please refer to www.eurovent-certification.com.
37
38
COMFORT LINE
Available options
Available unit options
Description Size 1 Size 2 Size 3 Size 4 Size 5 Size 6
Surcharge for 200 mm supply air spigots 7344898 7344888 7344889 7344910 7344911 7380251
(for model Y) £27 £33 £42 £45 £51 £92
Surcharge for 200 mm supply and return 7344898 + 7344888 + 7344889 + 7344910 + 7344911 + 7380251 +
air spigots (for model H) 7344936 7344930 7344931 7344941 7344942 7380259
£66 £78 £99 £110 £129 £209
Epure filter £18 £28 £27 £33 £47 £66
39
40
41
MAJOR LINE
Cabinet and concealed unit options
Available unit options
Description Total price, £ Total price, £ Total price, £ Total price, £ Total price, £ Total price, £
2-pipe units 102 202 302 402 502 602
4-way water control valve* 83 83 83 83 - -
E037567
4-way water control valve* - - - - 99 99
E037575
2-way water control valve* 70 70 70 70 - -
E037605
2-way water control valve* - - - - 81 81
E037567
42
• Dual flow ‘plug and play’ air handling unit. FLOWAY ACCESS
• Double filtration (F7 and F9).
• Rotary heat exchanger with constant speed. Air handling unit
• Free cooling and night cooling management.
• EC fan motor.
• Casing mechanical strength = D2.
• Air leakage (± pressure) = L2.
• Air leakage filter assembly = F9.
• Thermal transmittance = T3.
• Thermal bridge = TB2.
43
FLOWAY ACCESS
Air handling unit accessories
Accessories
Floway Access 1000 2000 3000 5000 7500
Description
Filter - F9 HEE £ 77 115 132 232 271
Set of aluminum fans (supply and exhaust) £ 1132 1456 1809 Inc Inc
Energy meter with communication £ 843 1,155 1,155 1,155 1,155
Actuator damper – indoor AHU £ 128 168 343 375 415
Dimensions mm 250 diameter 355 diameter 1150 x 560 1450 x 650 1750 x 840
Actuator damper – outdoor AHU £ 296 312 343 375 415
Dimensions mm 370 x 370 470 x 470 1150 x 560 1450 x 650 1750 x 84
Flexible sleeve (intake OR discharge) £ 17 20 76 91 112
Dimensions mm 250 dia 355 dia 990 x 510 1290 x 610 1590 x 810
Roof £ 346 363 389 449 518
Hood £ 184 200 228 256 287
Separator screen for hood £ 28 44 80 96 119
Adjustable feet £ 64 96 128 128 128
Quantity 4 6 8 8 8
Multi-units display (1-30) (display + TCONN card) £ 160 160 160 160 160
LON PCB £ 280 280 280 280 280
KNX PCB £ 280 280 280 280 280
Modbus TCP – BACnet IP PCB £ 359 359 359 359 359
Webserver PCB £ 439 439 439 439 439
IAQ sensor kit (CO2) £ 559 559 559 559 559
Constant pressure management kit £ 203 203 203 203 203
Ambient in-room control kit £ 184 184 184 184 184
Smoke detector kit £ 319 319 319 319 319
RJ11 cable 10 m/50 m £ 14/53 14/53 14/53 14/53 14/53
44
• Dual flow ‘plug and play’ air handling unit. FLOWAY CLASSIC
• Double filtration (F7 and F9).
• Rotary heat exchanger with variable speed. Air handling unit
• Free cooling and night cooling management. Rotary heat exchanger
• EC fan motor.
• Electrical pre-heater available = -15°C heat recovery.
• Casing mechanical strength = D2.
• Air leakage (± pressure) = L2.
• Air leakage filter assembly = F9.
• Thermal transmittance = T3.
• Thermal bridge = TB2.
Floway Classic 1000 2000 3000 4000 5000 6000 7500 10000 10000 15000 15000
Air flow m3/s 0.30 0.55 0.90 1.15 1.35 1.70 2.20 2.80 3.10 3.80 4.10
Minimum air flow m3/s 0.083 0.139 0.194 0.25 0.25 0.389 0.389 0.695 0.695 0.834 0.834
Maximum air flow m3/s 0.333 0.694 1.028 1.583 1.583 2.361 2.361 3.889 3.889 5.000 5.000
V air filter section m/s 1.21 1.42 1.42 1.16 1.45 1.18 1.57 1.59 1.91 1.65 1.98
Recovery efficiency EN308* % 78.8 79.4 79.3 78.8 79.9 79.1 79.5 79.3 77.9 79.5 78.4
Width x height mm 810 x 1010 x 1210 x 1510 x 1510 x 1810 x 1810 x 1920 x 1920 x 2192 x 2192 x
958 1158 1359 1659 1659 1959 1959 2090 2090 2340 2340
Length mm 1266 510 + 800 + 800 + 800 + 800 + 800 + 1100 + 1100 + 1100 + 1100 +
800 800 800 800 800 800 1100 1100 1200 1200
Weight kg 201 309 432 558 604 702 751 955 955 1250 1250
Supply power kW 1.43 2.5 3.82 4.23 4.23 6.03 6.03 12.06 12.06 15.45 15.45
Supply Phase 1Ø 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T 3Ø + T
Price** £ 7,517 9,871 12,262 13,998 15,674 17,260 18,937 22,231 22,231 26,161 26,161
Floway Classic cooling and heating/cooling only coil (2-row) - inside the unit
Fan motor assembly supply W 317 546 866 997 1219 1463 2166 2783 3481 4135 4707
Fan motor assembly exhaust W 266 473 715 882 1043 1334 1911 2213 2593 3095 3484
Specific fan power kW/m3s 1.945 1.852 1.756 1.633 1.676 1.645 1.853 1.784 1.959 1.903 1.998
Changeover coil capacity kW 4.0 7.3 11.9 15.2 17.9 22.5 29.1 37.1 41.1 50.3 54.3
(heating)***
Changeover coil capacity kW 5.7 10.5 17.1 21.9 25.7 32.3 41.8 52.2 58.9 72.2 77.9
(cooling)****
Price** £ 8,355 10,764 13,340 15,196 16,862 18,801 20,398 23,788 23,788 27,818 27,818
* ERP regulation UE 1253/2014.
** Includes casing/heat recovery/control and display/set of fans/M5 and F7 filter/Modbus.
*** Capacity at (W 45-40°C).
**** Capacity at (W 7-12°C).
45
FLOWAY CLASSIC
Air handling unit accessories
Rotary heat exchanger
Accessories
Floway Classic 1000 2000 3000 4000 5000 6000 7500 10000 15000
Description
Filter - F9 HEE £ 77 115 132 232 232 271 271 321 362
Water coil H & C/CO (4-row) - inside the unit £ - - - - - - - 2,076 2,315
Water coil HO (1-row) - additional casing £ 1,022 1,182 1,413 1,669 1,669 2,044 2,044 - -
Water coil H & C/CO (2-row) - additional casing £ 1,142 1,277 1,533 1,780 1,780 2,188 2,188 - -
Water coil H & C/CO (3-row) - additional casing £ 1,237 1,477 1,836 - - 3,034 3,034 - -
Water coil H & C/CO (4-row) - additional casing £ - - - 2,554 2,554 - - - -
Electric heater (1-stage) – inside the unit £ 878 974 1,118 1,214 1,261 1,429 1,477 - -
Electric heater (2-stage) – inside the unit £ 942 1,086 1,205 1,205 1,341 1,509 1,557 1,847 3,209
Electric heater (1-stage) – additional casing £ 1,261 1,437 1,652 1,876 1,924 2,235 2,283 - -
Electric heater (2-stage) – additional casing £ 1,326 1,549 1,741 1,956 2,004 2,315 2,362 - -
Motorised damper £ 128 168 343 375 375 415 415 415 527
Dimensions 250 dia 355 dia 1150 x 560 1450 x 650 1450 x 650 1750 x 840 1750 x 840 1750 x 840 2010 x 880
Outdoor motorised damper £ 296 312 343 375 375 415 415 415 527
Dimensions mm 370 x 370 470 x 470 1150 x 560 1450 x 650 1450 x 650 1750 x 840 1750 x 840 1750 x 840 2010 x 880
Flexible sleeve (intake OR discharge) £ 17 20 76 91 91 112 112 112 128
Dimensions mm 250 dia 355 dia 990 x 510 990 x 510 1290 x 610 1590 x 810 1590 x 810 1590 x 810 1900 x 810
Partial mixing section £ 200 224 271 296 296 319 319 527 575
(internal recycling damper)
Total mixing section £ 790 846 958 1,046 1,046 1,149 1,149 1,357 1,629
(internal recycling + 2 external dampers)
Roof £ 346 363 389 449 449 518 518 583 647
Hood £ 184 200 228 256 256 287 287 359 447
Separator screen for hood £ 28 44 80 96 96 119 119 168 200
Adjustable feet £ 64 96 128 128 128 128 128 128 128
Quantity 4 6 8 8 8 8 8 8 8
Epoxy coating for rotary heat exchanger £ 231 352 471 567 655 767 1,022 1,261 1,676
Hygroscopic coating for rotary heat exchanger £ 152 191 231 263 335 375 487 583 734
Pre-painted fins on coils – 1-row £ 6 11 13 26 26 42 42 - -
Pre-painted fins on coils – 2-row £ 11 20 33 51 51 82 82 95 128
Pre-painted fins on coils – 3-/4-row £ 19 33 39 102 102 125 125 188 256
Multi-units display (1-30) (display + TCONN card) £ 359 359 359 359 359 359 359 359 359
LON PCB £ 280 280 280 280 280 280 280 280 280
KNX PCB £ 280 280 280 280 280 280 280 280 280
Modbus TCP – BACnet IP PCB £ 359 359 359 359 359 359 359 359 359
∆P sensor for HR icing management £ 119 119 119 119 119 119 119 119 119
IAQ sensor kit (CO2) £ 559 559 559 559 559 559 559 559 559
Constant pressure management kit £ 203 203 203 203 203 203 203 203 203
Ambient in-room control kit £ 184 184 184 184 184 184 184 184 184
Smoke detector kit £ 319 319 319 319 319 319 319 319 319
RJ11 cable 10 m/50 m £ 14/53 14/53 14/53 14/53 14/53 14/53 14/53 14/53 14/53
46
• Counter flow ‘plug and play’ air handling unit. FLOWAY CLASSIC
• Double filtration (F7 and F9).
• Plate heat exchanger with variable speed. Air handling unit
• Free cooling and night cooling management. Plate heat exchanger
• EC fan motor.
• Electrical pre-heater available = -15°C heat recovery.
• Casing mechanical strength = D2.
• Air leakage (± pressure) = L2.
• Air leakage filter assembly = F9.
• Thermal transmittance = T3.
• Thermal bridge = TB2.
Floway Classic cooling and heating/cooling only coil (2-row) - inside the unit
Fan motor assembly supply W 312 550 933 1063 1637
Fan motor assembly exhaust W 253 483 798 941 1517
Specific fan power kW/m3s 1.881 1.878 1.923 1.743 1.855
Changeover coil capacity (heating)*** kW 6.1 11.2 17.3 23.5 34.7
Changeover coil capacity (cooling)*** kW 5.7 10.5 17.1 21.9 32.3
Price** £ 8,355 10,764 13,340 15,196 18,801
* ERP regulation UE 1253/2014.
** Includes casing/heat recovery/control and display/set of fans/M5 and F7 filter/Modbus.
*** EN308 conditions: Dry performance, altitude 0 m, iso air flow: Fresh air 5°C/80%; Exhaust air 25°C/27%.
47
FLOWAY CLASSIC
Air handling unit accessories
Plate heat exchanger
Accessories
Floway Classic 1000 2000 3000 4000 6000
Description
Filter - F9 HEE £ 77 115 132 232 271
Water coil HO (1-row) - additional casing £ 1,022 1,182 1,413 1,669 2,044
Water coil H & C/CO (2-row) - additional casing £ 1,142 1,277 1,533 1,780 2,188
Water coil H & C/CO (3-row) - additional casing £ 1,261 1,437 1,836 - 3,034
Water coil H & C/CO (4-row) - additional casing £ - - - 2,554 -
Electric heater (1-stage) – inside the unit £ 878 974 1,118 1,214 1,429
Electric heater (2-stage) – inside the unit £ 942 1,086 1,205 1,205 1,509
Electric pre-heater (1-stage) – inside the unit £ 1,009 1,149 1,322 1,501 1,788
Electric heater (1-stage) – additional casing £ 1,261 1,437 1,652 1,876 2,315
Electric heater (2-stage) – additional casing £ 1,326 1,549 1,741 1,956 2,315
Motorised damper £ 128 168 343 375 415
Dimensions, mm mm 250 dia 355 dia 1150 x 560 1450 x 650 1750 x 840
Outdoor motorised damper £ 296 312 343 375 415
Dimensions, mm mm 370 x 370 470 x 470 1150 x 560 1450 x 650 1750 x 840
Flexible sleeve (intake OR discharge) £ 17 20 76 91 112
Dimensions, mm mm 250 dia 355 dia 990 x 510 990 x 510 1590 x 810
Roof £ 346 363 389 449 518
Hood £ 184 200 228 256 287
Separator screen for hood £ 28 44 80 96 119
Adjustable feet £ 64 96 128 128 128
Quantity 4 6 8 8 8
Epoxy coating for plate heat exchanger £ 231 352 526 706 1,099
Pre-painted fins on coils – 1-row £ 6 11 13 26 42
Pre-painted fins on coils – 2-row £ 11 20 33 51 82
Pre-painted fins on coils – 3-/4-row £ 19 33 39 102 125
Multi-units display (1-30) (display + TCONN card) £ 359 359 359 359 359
LON PCB £ 280 280 280 280 280
KNX PCB £ 280 280 280 280 280
Modbus TCP – BACnet IP PCB £ 359 359 359 359 359
∆P sensor for HR icing management £ 119 119 119 119 119
IAQ sensor kit (CO2) £ 559 559 559 559 559
Constant pressure management kit £ 203 203 203 203 203
Ambient in-room control kit £ 184 184 184 184 184
Smoke detector kit £ 319 319 319 319 319
RJ11 cable 10 m/50 m £ 14/53 14/53 14/53 14/53 14/53
48
Floway Vertical Plate heat exchanger with variable speed M5 and F7, plate heat exchanger, EC plug fan, Modbus, display
Price £ 7,279 9,125 10,382
Accessories
Description Size 700 Size 1500 Size 2000
Intake motorised damper £ 128 168 168
Flexible intake sleeve £ 17 20 20
Built-in single-stage electric heater £ 671 886 1,078
Built-in 1-row heating coil with valves £ 671 702 734
External single-stage electric heater £ 1,261 1,4137 1,437
External 1-row heating coil with valves £ 1,248 1,182 1,182
External 2-row heating/cooling coil with valves £ 1,142 1,277 1,277
External 3-row heating/cooling coil with valves £ 1,237 1,477 1,477
49
Floway Ceiling Hot Water Coil Plate heat exchanger with variable speed M5 and F7, plate heat exchanger, EC plug fan, Modbus, display
Price £ 6,646 8,528 9,958
Accessories
Description Size 700 Size 1200 Size 1600
Intake motorised damper £ 202 223 223
Flexible intake sleeve £ 29 33 33
External single-stage electric heater £ 1,261 1,341 1,413
External 1-row heating coil with valves £ 1,022 1,182 1,182
External 2-row cooling coil with valves £ 1,142 1,277 1,277
External 3-row heating/cooling coil with valves £ 1,237 1,477 1,477
50
51
Space IPJ 90 120 140 160 180 190 200 220 240 280 320 360 380
Cooling capacity kW 22.5 28.3 34.7 38.6 42.9 45.5 53.1 57.7 60.3 67.7 71.3 80.2 90.0
Power input kW 7.3 9.4 11.0 12.6 14.2 15.1 17.2 19.1 20.1 21.9 23.4 26.4 29.9
EER 3.10 3.01 3.16 3.06 3.01 3.01 3.09 3.03 3.01 3.09 3.05 3.04 3.01
Heating capcaity kW 22.0 28.1 33.7 38.2 42.4 45.3 51.5 56.7 59.5 67.9 72.2 80.8 90.9
Power input kW 6.0 8.0 9.6 10.9 12.3 13.3 15.0 16.6 17.4 19.5 20.9 23.6 26.7
COP 3.67 3.50 3.53 3.50 3.44 3.41 3.44 3.42 3.41 3.49 3.45 3.43 3.41
Outdoor circuit fan air flow m3/h 9.0 14.5 17.0 17.0 17.0 17.8 31.0 31.0 31.0 33.0 33.0 34.5 35.0
Available static pressure Pa 49 49 49 49 49 49 49 49 49 49 49 49 49
Indoor circuit supply fan air flow m3/h 5.1 6.5 8.7 9.25 9.45 9.45 12 12.5 12.5 16 16 16.5 16.5
Available static pressure Pa 117 117 117 147 147 147 196 196 196 196 196 245 245
Power supply V/ph/Hz 415/3/50
Maximum absorbed current A 18.5 26.5 30.5 33.5 37.5 38.0 44.3 49.9 50.1 50.2 53.7 62.3 67.5
Refrigerant charge kg 6.7 7.0 11.0 11.0 11.5 11.5 12.5 12.5 13.0 19.5 19.5 20.0 20.0
Weight kg 585 610 675 680 685 690 990 995 1040 1155 1160 1165 1170
Sound power level dB(A) 71 80 80 84 85 85 85 85 85 85 85 86 86
Price £ TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC
Cooling capacity in accordance with EN-14511-2013 for indoor temperature conditions 27ºC,19ºC WB and 35ºC outdoor temperature.
Heating capacity in accordance with EN-14511-2013 for indoor temperature conditions 20ºC and 6ºC WB outdoor temperature.
Total power input by compressor and motorised fans under nominal conditions in accordance with EN-14511-2013.
52
SPACE
Packaged unit options and accessories
Family Description In factory On site Price, £
Electrical power 400 V/3 ph/50 Hz (without neutral) ✓ TBC
Flow and CS: Cross flow with 2 dampers ✓ TBC
assembly CK: Cross flow with 3 dampers ✓ TBC
CA: Cross flow with axial return fan ✓ TBC
CP: Cross flow with lower return plug-fan ✓ TBC
CQ: Cross flow with upper return plug-fan ✓ TBC
CW: Cross flow with passive recovery ✓ TBC
TS: Tunnel flow with 2 dampers (for models 0200 to 0380) ✓ TBC
TP: Tunnel flow with return plug-fan (for models 0200 to 0380) ✓ TBC
TW: Tunnel flow with passive recovery (for models 0200 to 0380) ✓ TBC
Coil coating Coil with copper pipes and copper fins ✓ TBC
Coil with copper pipes and fins of an aluminium alloy (INERA®) ✓ TBC
Coil with copper pipes and aluminium fins with polyurethane coating ✓ TBC
Coil with copper pipes and aluminium fins with Blygold® coating ✓ TBC
Heating Auxiliary hot water coil: standard or great cold ✓ ✓ TBC
Auxiliary electrical heaters ✓ ✓ TBC
Natural or propane gas burner ✓* TBC
Gas boiler and auxiliary hot water coil ✓ TBC
Protection low Antifreeze protection kit for low temperature (<-10ºC) ✓ TBC
temperature Antifreeze protection kit for low temperature (<-14ºC) ✓ TBC
Indoor fan High available pressure of the indoor fan ✓ TBC
Low available pressure of the indoor fan ✓ TBC
Air filtration and Stop-drop in the indoor air coil ✓ ✓ TBC
stop-drop Gravimetric filters G4 with low pressure drop ✓ ✓ TBC
Gravimetric filters G4 + folded opacimetric filters M6, F7 or F9 ✓ ✓ TBC
Gravimetric filters G4 low pressure drop + folded opacimetric filters F7 or F9 ✓ ✓ TBC
Double stage of folded opacimetric filters (M6+F7, M6+F9, F7+F9 or F9+F9) ✓ ✓ TBC
Outdoor fan Axial 2-speed outdoor fan(s) directly coupled to the motor ✓ TBC
Insulation Ceramic fibre for thermal and acoustic insulation, Euroclass A2-s1, d0 (M0) ✓ TBC
Indoor unit Condensate drain pan in stainless steel ✓ ✓ TBC
Management of the overpressure ✓ TBC
Differential pressostat for the detection of clogged filters ✓ ✓ TBC
Outdoor unit Outdoor coil protective grille ✓ ✓ TBC
Stop-drop at the fresh air intake ✓ ✓ TBC
Anti-vibration mounts made of rubber ✓ ✓ TBC
Passive recovery Rotary heat exchanger with CW assembly ✓ TBC
Rotary heat exchanger with TW assembly ✓ TBC
Probes Ambient temperature probe: one NTC probe connected to the control board or one to four probes ✓ ✓ TBC
with RS485 communication
Ambient temperatute and humidity probe: one to four probes with RS485 communication ✓ ✓ TBC
CO2 air quality probe environment installed, duct-mounted or installed on a pLAN local network ✓ ✓ TBC
Smoke detecting station in accordance with the NF S 61-961 standard ✓ ✓ TBC
Free-cooling and Type of free-cooling: thermal, enthalpic or thermoenthalpic ✓ ✓ TBC
outdoor humidity Outdoor air humidity probe: supplied with the unit or installed on a pLAN local network ✓ ✓ TBC
Terminal and unit User terminal installed on the electric panel ✓ ✓ TBC
communication User terminal installed on the electric panel + graphic terminal remote up to 50 m or 200 m ✓ ✓ TBC
User terminal installed on the electric panel + graphic terminal remote up to 200 m ✓ ✓ TBC
Unit configuration: stand-alone, master or slave ✓ ✓ TBC
Communication cards: RS485 Modbus/Carel; Ethernet PCoWeb; RS485 LonWorks®; Ethernet ✓ ✓ TBC
BACnetTM; RS485 BACnetTM; RS485 Konnex
Miscellaneous Management of an humidifier with proportional or on/off control ✓ ✓ TBC
item 1 Energy meter ✓ ✓ TBC
Energy meter and calculation of the cooling and heating capacities ✓ ✓ TBC
Miscellaneous Compressor soft starter ✓ ✓ TBC
item 2 Tropicalised components on the electric panel: control board, cards and terminals ✓ TBC
High performance phase monitoring relay ✓ TBC
High performance magnetothermic switches ✓ TBC
Roofcurb Standardised pre-assembly roofcurbs with adjustable height (cross flow) ✓ TBC
Adaptation roofcurbs for replacing units on site (tunnel flow) ✓ TBC
* The gas burner is supplied installed into a pre-assembly roofcurb.
53
Water-Cooled/Heated Internal AHU Plug & Play, Internal/External AHU Bespoke AHUs for all applications including
HTM 03 01
Air flow rates: up to 1.66 m3/s Air flow rates: 0.13 to 5 m3/s Air flow rates: 2.8 to 7 m3/s
Heating capacity: 20 and 286 kW Cooling capacity: 5 to 130 kW Heating capacity: 20 and 286 kW
Cooling capacity: 19 and 277 kW Air flow rates: 0.28 to 3.35 m3/s Cooling capacity: 19 and 277 kW
Air flow rates: up to 12.8 m3/s Air flow rates: up to 12.8 m3/s
Air Heaters and Coolers, many versions Packaged Internal and Split Type Systems Swimming Pool and
and applications Dehumidification Systems
Heating capacity: 7 and 110 kW Heating capacity: 21 to 144.5 kW Heating capacity: 69 and 148 kW
Cooling capacity: 8 and 92 kW Cooling capacity: 19 to 135 kW Cooling capacity: 92 and 148 kW
Air flow rates: 0.04 to 4.7 m3/s Air flow rates: up to 5.7 m3/s Water removal capacity: 4 to 120 kg/h
54
Heating capacity: 42 to 162 kW Heating capacity: 190 to 500 kW Cooling capacity: 600 to 1350 kW
Cooling capacity: 38 to 160 kW Cooling capacity: 190 to 640 kW R134A screw compressor
R410A scroll compressor R410A scroll compressor
Heating capacity: 40 to 210 kW Heating capacity: 250 to 820 kW Heating capacity: 500 to 1400 kW
Cooling capacity: 35 to 180 kW Cooling capacity: 220 to 720 kW Cooling capacity: 370 to 1170 kW
R410A scroll compressors R410A scroll compressors R134A screw compressors
Air-Cooled Dry Cooler/Condenser Comprehensive Range of Packaged Hot Water System with Buffer
Reversible Heat Pumps Tank/Expansion Vessel/Heat Exchanger
55
Heating capacity: 8 to 16 kW
Heating capacity: 2 to 5.8 kW Heating capacity: 4.4 to 12 kW
Water storage volume: 150 to 300 l
Cooling capacity: 1.5 to 5 kW Cooling capacity: 4 to 10 kW
Electric heater: 2.75 kW
Heating capacity: 3.4 to 27 kW Heating capacity: 3.4 to 27 kW Heating capacity: 1.9 and 31.5 kW
Cooling capacity: 2.5 to 23.7 kW Cooling capacity: 2.5 to 23.7 kW Cooling capacity: 1.7 and 28 kW
Mini VRF Outdoor Unit VRF Outdoor Unit VRF High-Efficiency Outdoor Unit
MiNi-SMMSe - VRF 2-Pipe Heat Pump SMMSe - VRF 2-Pipe Heat Pump SMMSe - VRF 2-Pipe High-Efficiency
Heat Pump
56
VRF Heat Recovery Outdoor Unit VRF Flow Selector Boxes VN Units (Air-to-Air Heat Exchangers)
SHRMe - VRF 3-Pipe Heat Recovery Unit SHRMe - 3-Pipe Heat Recovery Units Standard with DX Coil and/or Humidifier
Air Handling Application DX Coils Split-System and VRF Full Design and Support Service
24/7/364 Technical Support The Original and Best Reward Scheme Designed to Reward Competence
57
With a CIAT maintenance contract you ensure regular service and maintenance requirements are met and you avoid the
adverse consequences of neglect. CIAT makes it easy for you to select a level of service that’s right for your operation.
CIAT engineers are highly-skilled in all building systems assessment. They have access to advanced diagnostic tools and
analysis software, which will quickly and accurately evaluate your entire infrastructure and identify opportunities for
improvements and cost-savings.
Our engineers are industry-served, which gives CIAT the ability to service and maintain equipment from any manufacturer.
CIAT is one of the best-trained service providers in the industry. Our engineers are trained on the most up-to-date
factory developments and all our engineers have to pass stringent health and safety tests along with ethics training.
Commissioning
We provide a full commissioning service carried out by professionally-trained, experienced engineers to ensure that
once acquired, your equipment is set up to function correctly and efficiently in order to optimise its performance.
When choosing to use our commissioning service you can rest assured that all of our commissioning service engineers are:
• Factory-trained to the highest standards by senior engineers who are involved in the actual design of the equipment.
• Fully-equipped with the required test instruments (fully-calibrated with certification available on request).
• Equipped with laptops and the software necessary to communicate with our controllers and unit strategies.
On-site instruction
In addition to our commissioning service we can also provide commissioning engineers for on-site instruction. This is
useful for those responsible for day-to-day unit operation (if not already covered by a CIAT Service and Maintenance
contract). Although this service is tailored to individual needs, it would typically include the following:
• Provision of the controls and operating and maintenance manuals. Introduction to the content of these manuals,
allowing you to highlight what you feel to be relevant.
• Basic navigation and explanation of the controller operation and alarm handling.
• Discussion about the general maintenance of the unit, covering mechanical items such as belts, motors and
electrical items, e.g. the humidifier and electrical panel.
58
5-Year Comprehensive
• CIAT Commission.
• CIAT Maintenance.
• Remote Monitoring.
• Available on selected sites only.
59
Parkfield House,
Northern Manchester Old Road,
Office Middleton,
Manchester, M24 4DQ
Porsham Close,
Registered Roborough,
Office Plymouth,
Devon, PL6 7DB
www.ciat.uk.com
This document is not binding. As part of its policy for continual product improvement, CIAT reserves the right to make any product improvements without prior notification.
All reproduction rights reserved. None of the content in this document may be reproduced, transmitted, sold, commercially exploited, or reused in any manner.