FX3U Series Programmable Controllers 4 Specifications, External Dimensions and Terminal Layout (Main Units)

User’s Manual - Hardware Edition 4.5 Performance Specifications

Introduction
Item Performance
1-phase 1-count input
in both directions (32 C235 to C245 Counting from -2,147,483,648 to
bits) [changeable] Up to 8 +2.147,483,647 [For keeping]
points can The retentive status can be changed by
1-phase 2-count input
be used in parameter settings.
High-speed
counter
in both directions (32 C246 to C250
range from → For the high-speed
2
bits) [changeable]

Part Names
Features and
C235 to counter operating
2-phase 2-count input C255. frequency, refer to the table
in both directions (32 C251 to C255 shown in the next page.
bits) [changeable]
For general (16 bits)
D0 to D199 200 points
[changeable] The retentive status can be changed by 3
For keeping (16 bits) parameter settings.

Introduction
Product
D200 to D511 312 points
[changeable]
Data register D1000 and later in 7488 points of fixed
For keeping (16 bits) D512 to D7999 7488 points
(32 bits when data register for keeping can be set as
[fixed] <D1000 to <7000
paired) file register points in 500-point units by
<File register> D7999> points>
changing the parameter settings.
For special (16 bits) D8000 to D8511 512 points −
4

Specifications
V0 to V7
For index (16 bits) 16 points −
Z0 to Z7
32768
Extension register (16 bits) R0 to R32767 Retained by battery during power failure
points

Extension file register (16 bits)


ER0 to
ER32767
32768 Usable only when memory cassette is
points mounted
5

Devices
Peripheral
Version and
For branching of For CJ instructions and CALL
P0 to P4095 4096 points
JUMP and CALL instructions
Input interruption and
Pointer input delay I0 to I5 6 points
interruption −

Timer interruption I6 to I8 3 points


6

Configuration
System
Counter interruption I010 to I060 6 points For HSCS instructions
Nesting For master control N0 to N7 8 points For MC instructions
16 bits -32,768 to +32,767
Decimal number (K)
32 bits -2,147,483,648 to +2,147,483,647
Hexadecimal number 16 bits 0 to FFFF 7

Nos., Unit Nos.


Input/Output
(H) 32 bits 0 to FFFFFFFF
Constant
Real number (E) 32 bits -1.0 x 2128 to -1.0 x 2-126,0,1.0 x 2-126 to 1.0 x 2128
Decimal-point and exponential notations are possible.
Designation by characters enclosed with " "
Character string (" ") Character string Up to 32 one-byte characters can be used for a
constant in an instruction. 8
Installation

Operating frequency of high-speed counter


For hardware and software counter device numbers, refer to the following section.
→ Refer to Section 11.5.
Input terminals (X000 to X007) High-speed input special adapter
Kind of high-speed counter
of main unit (FX3U-4HSX-ADP) 9
1-phase 100 kHz x 6 points, 10 kHz x 2 points 200 kHz x 8 points
Wiring
Power Supply
Preparation and

Hardware counter 50 kHz (multiply by 1), 100 kHz (multiply by 1),


2-phase
50 kHz (multiply by 4) 100 kHz (multiply by 4)
1-phase 40 kHz 40 kHz
Software counter 40 kHz (multiply by 1), 40 kHz (multiply by 1),
2-phase
10 kHz (multiply by 4) 10 kHz (multiply by 4) 10
Input Wiring