You are on page 1of 4

PARAMETER LIST FOR 201 WF 10 TUC 6 (4.1 Ver.) Job No.- 90.

868
TIL Engineer - Mr. Abhijit Edgaonkar

Sr. No. Parameters Value

1.0 Measuring Parameter 201WF-10 (150TPH)

1.1 M. range 12mv


1.2 Units, X t/h
1.3 D. Pt, X 00000,0
1.4 Nom. Cap 1500
1.5 D. Pt, S1 0000,00
1.6 Units, S2 T
1.7 D. Pt, S2 00000,0
1.8 Units, S2 T
1.9 Freq Input Tacho
1.10 Tacho Freq 962
1.11 Belt Speed 0.26 s
1.12 Max. load 120,0
1.13 Min. load 010,0
2.0 Configuration Parameters
2.1 Block Mode NO
2.2 Regulation DIR
2.3 Batch Mode NO
2.4 Rev. Time 28.5.0s
2.5 No_Of_Rev 01
2.6 Zero Limit 10
2.7 Belt Track 010,0
2.8 Run Time 010,0
2.9 Impulse 1 S1
2.10 On time 250ms
2.11 Impulse 2 No
2.12 Limit 1 120,0
2.13 Limit 2 010,0
2.14 L_delay 010,0
2.15 Clear S2 No
2.16 Meas_Filt 3
2.17 Disp_Step 3
2.18 Mode_sel INT
2.19 Setpoint % 100%
2.20 Ctrl_mode PI
3.0 Interface
3.1 No. Of Inv 1
3.2 Inv type ACS550
3.3 No of DIO 2
3.4 AIO Type F875
3.5 No of AIO 1
3.6 Ext_SP AIO1
3.7 SP filter 1
3.8 AIO1_OP Tph
3.9 AIO2_OP Tph
3.10 AIO3_OP Ta
3.11 PC _ Int OFF
3.12 SIO_INT PROFIBUS
3.13 SIO_BAUD 19200
3.14 SIO_SETUP 8,1,NP
3.15 SIO_ADDRESS 01
3.16 SIO_MON 00
3.17 CAN_INT OFF
4.0 Main Program SET1
4.1 I1_Time 010,0sec
4.2 P1_gain 020,0%
4.3 Dev_Limit 030,0%
4.4 Dev_Time 000,0s
4.5 I2_time 000,0s
4.6 P2_gain 000,0%
4.7 Dead_Band 000,0
5.0 Main program SET2
5.1 W1 Grav. Setpoint
5.2 Wm Vol. Setpoint
5.3 % limit 100,0 %
6.0 Main Program Set4
6.1 Count_DL 02186
6.2 Span_Cnt 05099
6.3 AI_Tare
6.4 AI_Span
6.5 Rev_Time 28.5 s
6.6 Drv_Const 00
6.7 tCTRL_Cnt 00
Calibration Details

Tare mV 3.34
Span mV 8.70
Calibration Weight (Kg) 14.66
Calibration % 65.33
Calibration count (d) 1306
‘e’ – Distance (mm) 200

** All parameters as on 28.08.2012.

You might also like