EXAMPLE APPLICATION: RFX-1FS used with GFT-100/25 EXAMPLE APPLICATION: RFX-2F used with ALS-200
Stainless steel foil heat shield Stainless steel foil heat shield
25 50
*
Wall options are suitable for both drywall/stud and masonry applications and do not require stainless steel foil heat shield
**
Wall systems
^
To ensure proper functionality of the EJC it is critical that the Fire Barrier size is taken into account when sizing the joint opening. Contact us should you require specification assistance.
MULTIFLEX FIRE BARRIERS JOINT WIDTHS 25-500MM I FIRE RATING: 60 OR 120 MIN
A blanket style system designed for a wide range of joint widths and
large movement requirements. Composed of layers of stainless steel
foil and insulation, contained in a stainless steel mesh.
• Suitable for floor and wall joints 25mm to 500mm wide
• ANSI/UL 2079 and ASTM E1966 tested for 1-hour and 2-hour rating,
including cycling capabilities of ±50% horizontal movement. Lateral
shear movement of ±50% can also be accommodated, along with
vertical deflection of ±50mm.