You are on page 1of 6

InteliNanoNT

GEN-SET CONTROLLER

Description
InteliNanoNt is a cost effective diesel
and gasoline generator set controller
which offers outstanding protection,
monitoring and control for small
and middle size generator sets.

there are two different types available:

 MRs
 AMF
 PLus

the InteliNanoNt MRs, AMF


and PLus boast large and powerful
graphical displays.

All InteliNanoNt controllers communicate


with license-free PC software via the
integrated usb port for your convenience.

this software allows users to


configure all the inputs, outputs and
important parameters freely, as well
as update the controller’s firmware
to suit individual requirements.

All InteliNanoNt controllers can


communicate via standard and proprietary
CAN J1939 communication protocols to
a wide range of EFI engines, which include
Caterpillar, Cummins, Detroit Diesel,
Deutz, GM, Isuzu, Iveco, John Deere,
Kubota, MAN, Mtu, Perkins, scania,
Benefits sisu, Volvo Penta, Yanmar and others.

 supercompact and attractive design  “Zero” power consumption  ComAp’s uncompromised


 Integrated solution – less wiring mode, i.e. extended battery life quality and performance
and external components  Weak battery genset starting  MRs and AMF in one model,
 standard industrial cutout dimensions  Event Log (10 events) i.e. one stock only
 the biggest graphical display  Easy and user-friendly  High speed engine support
in its class installation / operation  Dedicated for diesel and gasoline engines
 Language free, on display only symbols  Perfect price / performance ratio  shorter commisioning time – usb
and numbers, no translation needed  usb one cord programming one-cord power supply and programming
 usb communication interface and CAN  All setpoints and I/O’s
for outstanding support of EFI engines configurable via front panel

ComAp is a member of ComAp products meet the highest


AMPs (the Association of standards, with every stage of production
Manufacturers of Power undertaken in accordance with the IsO
generating systems). certification obtained in 1998.
Features

 3 phase mains measurement  History  Communication interface


• Over/under frequency • Running hours • usb on board
• Over/under voltage • 10 events, warnings or shutdown • CAN interface (J1939 only)
• Phase rotation alarms with running hours stamp
• Yellow and red alarms from ECu  Mechanical and operation
 3 phase generator protection 7) parameters
• Over/under frequency  Inputs and outputs • unit dimension 118 × 108 mm
• Over/under voltage • 3 configurable analog inputs with • Cutout dimension 96 × 96 mm
• Phase rotation wide list of predefined senders 2) • sealed front face rated for
• Overcurrent/Overload 6) • COM terminal for analog inputs IP65 for GAsKEt 4x405 4)
• 6 binary inputs 3) • Operation temperature
 True RMS voltage measurement • 1 binary input is dedicated for -20 °C to +70 °C
• 3 phase mains voltage 1) controller remote wake up • Power supply voltage 5 – 36 V
• 3 phase generator voltage 7) • All outputs have positive • Voltage drops shorter than
• Voltage range 277 V p-n, 480 V p-p logic (high side) 50 ms do not affect operation
• Maximal measured voltage 300 V p-n • All outputs are overcurrent protected
• 2 high current 6 A long – 10 A short InteliNanoNT controllers support
 True RMS current measurement 6) • 4 low current 0,5 A J1939 for all major brands:
• 1 generator phase current • D+ pre-excitation terminal • Caterpillar • MAN
• Current range 5 A • Cummins • Mtu
• Maximal measured current 10 A  EFI engine support • Detroit Diesel • Perkins
• Ct ratio range 1 – 5000 • Deutz • scania
• Engine specific J1939 for all major
• GM • sisu
manufacturers (see table right)
• Isuzu • Volvo Penta
 Engine protection • Diagnostic messages • Iveco • Yanmar
• Over/under speed (sPN, FMI number) • John Deere and others
• High temperature • Kubota
• Oil pressure  Miscellaneous features
• Low fuel warning • “Zero” power consumption mode
• battery flat detection • Maintenance warning
• Customer logo screen
 User interface • Weak battery genset starting Key:
• Graphic 128 × 64 pixel display • usb one-cord power supply 1)
Only for AMF model
• Icon menu, no text and programming 2)
Analog inputs are shared with binary inputs
• setpoints adjustable via • All setpoints and I/O’s 3)
1 binary input is shared with binary output
controller buttons or PC configurable via front panel 4)
Optional GASKET has to be ordered separately
• buttons with mechanical feedback • AMF and MRs in one model 1) 5)
Only when AMF mode is disabled
• special LCD screen / Light • Voltage autodetect 5) 6)
Only for InteliNano Plus model
tower support • Gasoline engine 7)
InteliNano Plus – 3 phases
support-choke output in MRS mode / 1 or 2 phases in AMF mode

Order codes ANSI CODES

Item Order code ANSI code Protection

InteliNano Nt
MRs IN-Nt MRs 59 Overvoltage

InteliNano AMF
Nt
IN-Nt AMF 27 undervoltage

InteliNanoNt PLus IN-Nt PLus 81H Overfrequency

IP65 Gasket GAsKEt 4x405 81L underfrequency

47 Phase rotation*

71 Gas level

* Fixed setting

InteliNano NT
Typical aplications

PRIME MOVER SYSTEM


 Manual and remote start
of gen-sets with electronic
engines. InteliNanoNt MRs
S
MR
starts, controls and monitors the liNa
no
T
N

Inte
gen-set and controls the circuit
breaker to supply the load.
 Generator is protected by built
in over/under voltage and
frequency protection systems.
 Controller communicates with
engine management unit via
CAN J1939 bus and shows no
NT Plu
s
liNa
Inte
engine values and alarms
on graphical LCD screen.
 Prolonged battery lifetime
– controller enters to sleep
mode when generator
is not used long time.
 special LCD screen for
Light tower support

STANDBY SYSTEM
 stand-by gen-set with electronic
engine. InteliNanoNt AMF
continuously monitors a mains
supply and automatically S
MAIN
starts an engine and switches
load to a standby generator
set in case of failure.
 Generator is protected by built
in over/under voltage and
frequency protection systems.
R
ITTE oN A
MF
 Controller communicates with NSM
T

RA Nan
TV T Inteli
engine management unit by
CAN J1939 bus and shows
engine values and alarms
9
on graphical LCD screen. J193
M
ROO
INE
ENG

SET
GEN

InteliNano NT
GND

Schematic diagrams PC

SUPPLY

ALA
POWER VDC
5 to 36 -

RM
+ USB

STO
PUTS
RY OUT
4 BINA

P
BE
UP TO DE) – 2 CAN UIT
SI
(HIGH TED FOR CIRC
L
6 DEDICA RS CONTRO
UP TO INPUTS BREAKE
BINARY

F
an oNT AM
InteliN MAINS

MEA
ATOR CAN -
J1939
GENER

VOL

SUR
InteliNano NT
MRS

MEA

TAG

EME
VOL

SUR
3
UP TO

E
E
ENGIN

NT
G

TAG
ANALO

EME
RY
2 BINA
OUTPU
TS INPUTS

NT
GND (HIGH T–
CURREN DE)

GEN

MAIN
D+ – HI G H SI

E
RAT

SC
Coo
PC

Fue

OR

.B. C
Oil P

3ph
Start

lant
Fue

l Le

C
SUPPLY

ONT
.B. C
ress
Aux xcitatio
ALA

Pre

er
POWER VDC

l So

3ph
Tem
MAINS

vel
5 to 36

R
ure
e
-

Alte

ONT
RM

leno

OL
+

pera
USB
STO

PUTS

rnato
RY OUT

R
id

ture
2 BINA

OL
P

BE
UP TO DE) – 1 CAN UIT

n
r
IG H SI R CI RC
(H TED FO L
6 DEDICA RS CONTRO
UP TO INPUTS BREA KE
BINARY

ano
NT MRS LOAD

InteliN GENER
ATOR CAN -
J1939
11

Values
+ Fault
Codes
MEA

ATO R
GENER quest
VOL

SUR

3 eed Re J1939
E UP TO top - Sp
ENGIN G LINE Start/S
/ GASO
TAG

ANALO
EME

RY
2 BINA DIESEL
OUTPU
TS INPUTS
E

(HIGH
T

T– 1 ECU
CURREN DE)
GEN

SI
D+ – HIGH
E

InteliNanoNT AMF
RAT
Coo
Oil P

OR
Start

lant
Fue

C
re
Aux xcitatio

.B. C
Pre

er

ssu
l So

3ph
Tem
e

re
Alte

leno

ONT
pera
rnato

id

ROL
ture
n
r

LOAD

1
Codes
+ Fault
Values
OR GND
GENERAT quest
eed Re J1939
LINE top - Sp
ASO Start/S
DIE SEL / G

PC
1 ECU
SUPPLY
ALA

POWER VDC
5 to 36 -
RM

+ USB
STO

PUTS
RY OUT
4 BINA
P

BE
UP TO DE) – 2 CAN UIT
SI
(HIGH TED FOR CIRC
L
6 DEDICA RS CONTRO
UP TO INPUTS KE

s
EA

oNT Plu
BR
BINARY

an
InteliN plicatio
n MAINS
MEA

AMF ap ATOR CAN -


J1939
GENER
VOL

SUR
MEA

InteliNanoNT PLUS
TAG

EME
VOL
CUR

SUR

3
UP TO
E

E
TAG

ENGIN
NT

G
ANALO
REN

EME

RY
2 BINA
INPUTS
E

TS
OUTPU
T

NT

(HIGH T–
CURREN DE)
GEN

MAIN

SI
GND D+ – HIGH
ERA

SC
TOR
Coo
Fue

.B. C
Oil P

3ph
Start

lant
Fue

l Le

C.B

PC
O
ress
Aux xcitatio
Pre

er

NTR
l So

1ph
Tem

MAINS
vel

. CO
1ph
ure
e
Alte

SUPPLY
leno

OL
pera
ALA

POWER VDC
NTR
rnato

5 to 36
id

-
RM

ture

OL

+ USB
n
STO

PUTS
RY OUT
4 BINA
P

BE
UP TO DE) – 2 CAN UIT
SI
(HIGH TED FOR CIRC
L
6 DEDICA RS CONTRO
UP TO INPUTS KE

Plus
BR EA
BINARY LOAD
NT
no
nteliNa
11

IMRS ap
plicatio
n
ATOR CAN -
J1939
Values
+ Fault Code
s

GENER GENER
ATOR
d Requ
est
MEA

ee J1939
top - Sp
LINE Start/S
/ GASO
VOL
CUR

DIESEL
SUR

3
E UP TO
TAG

ENGIN G
REN

ANALO
EME

RY
2 BINA ECU
INPUTS
E

TS 1
OUTPU
T

NT

(HIGH T–
CU EN DE)
RR
GEN

SI
D+ – HIGH
ERA
Coo

TOR
Oil P
Start

lant
Fue

C.B
ress
Aux xcitatio
Pre

er
l So

3ph
Tem

1ph

. CO
ure
e
Alte

leno

pera

NTR
rnato

id

ture

OL
n
r

LOAD

1
Codes
+ Fault
Values
OR
GENERAT quest
eed Re J1939
top - Sp
OLINE Start/S
L / GAS
DIESE

1 ECU

InteliNano NT
Available models

InteliNanoNT MRS InteliNanoNT AMF InteliNanoNT PLUS


MANUAL AND REMOTE AUTOMATIC MAINS FAILURE AMF AND MRS CONTROLLER
START CONTROLLER WITH START CONTROLLER WITH WITH CURRENT MEASUREMENT
SUPPORT FOR EFI ENGINE SUPPORT FOR EFI ENGINE AND SUPPORT FOR EFI ENGINE

 3 phase generator voltage  3 phase mains voltage  3 phase mains voltage measurement
measurement measurement  1/3 1) phase generator
 up to 3 analog inputs (shared with  3 phase generator voltage voltage measurement
binary inputs) measurement  1 phase generator current
 COM terminal for analog  up to 3 analog inputs measurement
measurement (shared with binary inputs)  up to 3 analog inputs
 up to 6 binary inputs (1 binary  COM terminal for analog (shared with binary inputs)
input is shared with binary output) measurement  COM terminal for analog
 2 high side – high current outputs  up to 6 binary inputs (1 binary measurement
 2 high side binary outputs input is shared with binary output)  up to 6 binary inputs (1 binary input
 Automatic or manual GCb control  2 high side – high current outputs is shared with binary output)
 CAN J1939  4 high side binary outputs  2 high side – high current outputs
 usb  Automatic or manual MCb and  4 high side binary outputs
 big graphical LCD GCb control  Automatic or manual MCb
 D+ pre-excitation terminal  CAN J1939 and GCb control
 “Zero” power consumption  usb  CAN J1939
 big graphical LCD  usb
 D+ pre-excitation terminal  big graphical LCD
 “Zero” power consumption mode  D+ pre-excitation terminal
 AMF and MRs in one model  “Zero” power consumption mode
 AMF and MRs in one model

Key:
1)
3/3 phase when used as MRS controller
References

Slovenia
STUBELJ

Stubelj is a Slovenian company with 25 years experience of producing


and selling 2.0 – 2000 kVA generating sets, and providing
all services connected with this business.

„Our company has been using ComAp controllers for many years.
We have had a good long-term experience with InteliLiteNT and InteliGenNT
controllers. We are now using the new InteliNanoNT controllers
on our smaller generating sets, which we are very happy with.
The InteliNanoNT gen-set controllers provide protection, monitoring
and control to small-to-medium sized generator sets and pack
plenty of power into a small unit at a very good price.”

Marko Stubelj
Purchasing Manager
www.stubelj.si

InteliNano NT
Functions chart for InteliNanoNT models
InteliNanoNT MRS InteliNanoNT AMF InteliNanoNT PLUS

Model MRS AMF PLUS

Order code IN-NT MRS IN-NT AMF IN-NT PLUS

Binary inputs/outputs 6/4 1) 6/6 1) 6/6 1)

Analog inputs 3 2) 3 2) 3 2)

AMF function – l l

MRS function l l l

Input configuration l l l

Output configuration l l l

Voltage measurement Gen. / Mains 3 ph / – 3 ph / 3 ph 1 ph 4)


/ 3 ph

Current Measurement – – 1 ph

Voltage autodetect l l 3) l 3)

Generator protections l l l

Event log / Running hours history l l l

GCB/MCB control with feedback l/– l/l l/l

D+ battery charging alternator circuit l l l

Engine hours l l l

CAN-J1939 interface l l l

USB communication port l l l

LCD screen l l l

Alarm LED l l l

Weak battery genset starting l l l

Maintenance warning l l l

“Zero” power consumption l l l

Light tower support l l 3)


l 3)

IP65 ¢ ¢ ¢

Key:  1)
1 binary input is shared with binary output 2)
Analog inputs are shared with binary inputs
3)
Only when AMF function is disabled 4)
3 ph when used as MRS controller l included – excluded ¢ optional

For more information about our products and applications visit

www.comap.cz
Manufacturer: Local Distributor / Partner:

ComAp, spol. s r. o.

Czech Republic
Phone: + 420 246 012 111
Fax: + 420 266 316 647
E-mail: info@comap.cz
Internet: www.comap.cz

Customer satisfaction is our mission. We continuously develop the best people to succeed in our mission.

© ComAp. Features and specification are subject to change without prior notice. 2012-11/CPLENANO

You might also like