You are on page 1of 74

Eaton

Hydrokraft Open Loop Piston Pumps X Series


Contents

Introduction LR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 A20 - size 066-180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Typical Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 A20 - size 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Model Codes A2F - size 066-180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Basic Pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 A2F - size 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
DF Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 A30 - size 066-180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
LR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 A30 - size 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
ST Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 ST Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
FM Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 STC03A00. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
ZP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 STC03A40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 STC03A4F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
ES Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 STC03A4K. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
NO Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 STC03A4K_ _ _ _C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Combination pump units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 STC03A4B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Pump Specifications STC03A4L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Metric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 STC03A50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
US. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 STC03A5F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Performance Curves STC03A5K. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

066 & 090 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 STC03A5L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

130 & 180 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 FM Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

250 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 FM000A0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60


ZP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Installation and Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
ZP100A0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Application Data and Fluid Recommendations . . . . . . . 21
SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Pump Dimensions
SPC03A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Variable Displacements
ES Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
PVXS-066 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
ES0N00A00 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
PVXS-090 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
PVXS-130 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 General Dimensions
PVXS-180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Fixed Displacement
PVXS-250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 PFXS-066 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Control Options PFXS-090 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
DF Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 PFXS- 130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
A0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 PFXS-180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
A10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Thru-Drive Options
A0F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
066-090. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
A0S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
130-180. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
AA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
AB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
A0_ _ _ _ _100H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

2     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Introduction

• Axial piston pumps with • Rotating and pressure-loaded • "Building block" design gives Available displacement sizes
swashplate design for parts are pressure balanced. these pumps a wide range of 66 ccm/rev
reliable operation and • Integrated pilot pump, application.
long life. 90 ccm/rev
filter and pressure relief
• Pressure up to 420 bar. valves available. 130 ccm/rev
Rated speed up to 180 ccm/rev
1800 min-1. Higher speeds
250 ccm/rev
possible on request.
• Oversize shafts and bearings.

Displacement controls Typical Section of Open Loop PVX Pump

DF - Pressure compensator
Proportional
LR - Power limiter control control valve

ST - Electronic flow control Spring Housing Control piston


FM - S
 crew adjustment
flow control
ZP - Dual displacement control
SP - Electronic flow control
ES - Electric motor flow control

Sleeve

Shaft

Bearing
Port plate

Bearing
Swash plate Cylinder barrel Valve plate

  Note
Dimensional data provided
in this catalog is subject to
change without notice.

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      3
Model code •

Preferred standard option
Other standard option
• Special option on request
Open Loop Pumps x Not available
X Series - Basic Pumps

PVX * – * * *M* * * * * * 1 * * * S * * A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
1 Pump 14 15 Thru drive options
P – Open loop pump • • • • • 00 – None • • • • •
2 Displacement 0A – SAE A • • • • •
0B – SAE B • • • • •
V – Variable • • • • • 0C – SAE C • • • • •
F – Fixed • • • • x 0P – Pilot pump (8cm3/rev) • • • • •
3 Pump Series 0X – For tandem units • • • • •
X – “X” series • • • • • 16 Main Ports
4 Configuration 1 – SAE ports - Metric bolts • • • • •
S – Single unit • • • • • 17 Main port orientation
F – Front unit • • • • •
M – Middle unit • • • • • R – Radial (side ports) • • • • •
R – Rear unit • • • • • A – Axial (in-line rear) • • • • •
For fixed units only radial ports available
5 Separator • • • • •
6 7 8 Displacement cm3/rev (in3/rev)
18 19 Main drive shaft end
066 – 066 cm /rev (4 in /rev)
3 3
• x x x x
01 – ISO straight key • • • • •
090 – 090 cm3/rev (5.5 in3/rev) x • x x x
02 – ISO spline • • • • •
130 – 130 cm3/rev (8 in3/rev) x x • x x 20 Drive shaft seal configuration
180 – 180 cm3/rev (11 in3/rev) x x x • x S – Single shaft seal • • • • •
250 – 250 cm3/rev (15.3 in3/rev) x x x x •
*** – Non-standard (PFX only) ◊ • • • • x 21 Seal material
◊ Non-standard displacements (cm3/rev): V – FKM • • • • •
066 – 44/50 F – FKM + front bearing flushing prepared • • • • •
090 – 75 K – FKM with HP lubrication • • • • •
130 – 94/112 L – For HFC Hp-Lub + front flushing • • • • •
180 – 160 M – For HFC Hp-Lub + front + rear flushing • • • • •
9 Basic Standard
G – For HFC front + rear flushing • • • • •
A – EPDM / PTFE • • • • •
M – Metric • • • • • 22 Yoke position indicator
10 11 Mounting Flange
0 –
No position indicator • • • • •
02 – ISO 3019/2-125A2SW • • x x x V –
Visual indicator • • • • •
04 – ISO 3019/2-160A2SW x x • • x P –
Voltage indicator • • • • •
06 – ISO 3019/2 200A2SW x x x x • M Voltage + visual indicator
– • • • • •
12 Rotation Direction L Current + visual indicator
– • • • • •
R – Clockwise • • • • x SP control only
L – Counter-clockwise • • • • x 23 Surface coating
13 Maximum displacement A – Primer blue • • • • •
0 – Max. displacement adjusting screw 0 – Rust inhibitor oil • • • • •
With control DF/ZP • • • • • Other finishes on request.
With control ST +DF • • • • • 24 Control model code
With control ST +LR x x x x x
With control LR/SP/FM/ES x x x x x See fields 24 to 48 on following pages.
4 – Fixed mechanical stop ring side A • • • • • Pump Size 66 90 130 180 250
(max displacement)
5 – Fixed mechanical stop ring side B • • • • •
(min. displacement)
Pump Size 66 90 130 180 250

Note: 
  66cc will get new design (similar to 90 cc) and all counter-clockwise of 66cc will be outfaced in 2018.

4     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control overview For additional control options
Please look into details of modelcoding

Open Loop Pumps


X Series - Basic Pumps

D F Pressure compensator
with or without load sense

L R Power limiter control


with or without pressure compensation
with or without load sense
Preferred
S T Electronic flow control
electrial feedback, neutral postion at max. displacement • shortest leadtime
with or without pressure and/or power limiter override • cost effective

F M Screw adjustment flow control


manual flow control by screw adjustment

Z P Dual displacement control


flow control for 2 displacements, switchable by on/off valve

S P Electronic flow control


electr. feedback, neutral position at zero displacement On request only
with or without pressure limiter override
• longer leadtimes
E S Electric motor flow control • standard pricing
electromechanical flow control with gearbox and limit switches

Note: FE, HG, DP, SM and DQ old controls should not be used anymore. If you need technical support here, please contact us at Hydrokraft@eaton.com.

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      5
Model code •

Preferred standard option
Other standard option

Open Loop Pumps


• Special option on request

X Series - DF Control

D F 0 0 0 A * * 0 0 0 0 * 0 0 * * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25Control Type 36 Venting valve
DF – Pressure compensator • • • • • 0 – None • • • • •
26 Displacement adjustment options
1 – Solenoid valve • • • • •
Specify voltage in 39
0 – Not applicable
37 Position monitoring
27 28 Electronic amplifier
0 – Not applicable
00 – Not applicable
38 Electric motor type
29 Yoke displacement zone
0 – Not applicable
A – Single side of centre “A” • • • • • 39 Control voltage
30 Additional functions 0 – Not applicable • • • • •
0 – None • • • • • H – 24V DC (preferred voltage) • • • • •
1 – Load sensing (standard ∆p = 15 bar) • • • • • B – 110V AC 50 Hz / 120V AC 60 Hz • • • • •
A – 2-level pressure compensator, • • • • • D – 230V AC 50 Hz / 240V AC 60 Hz • • • • •
4/2 solenoid valve
40 41
B – 2-level pressure compensator, • • • • • Customer adjustment specification
42 43
4/3 solenoid valve
0000 – None • • • • •
31 Pressure control options • • • • •
**** – Eaton assigned number as per
0 – None i.e. pilot operated with remote port (stan- • • • • • data specified in table below ◊
dard arrangement) 44 45 46 Special features
F – Remote port without pilot valve • • • • •
K – Electro - proportional relief valve, • • • • • 000 – None • • • • •
complete with electronic card *** – Defined by Eaton • • • • •
L – Electro - proportional relief valve • • • • • 47 48 Design number
with OBE
S – Slow upstroke screw adjustment ** – 10-99 assigned by Eaton • • • • •
• • • • • Pump Size 66 90 130 180 250
32 33 34 Power control
000 – Not applicable
◊ Example for customer adjustment specifications
35 Pilot oil filter Special pressure Main stage Pilot valve Load
0 – Not applicable adjustment pressure control pressure control sense
∆p
Pump Size 66 90 130 180 250
Standard setting (bar) 20 90 15
Max. setting (bar) 40 350 40
Customer-specified adjustment
(bar) ....... ....... .......
Note: Setting must be at least 30bar.

Special max. Minimum Maximum


Displ. Adjustment displacement displacement
Standard 0 cm3/rev 100%
Customer-specified adjustment
(cm3/rev)
....... .......
Note: Special pressure adjustments and/or maximum displacment adjustments are the
most common reasons for using this option. Max. displacement adjustable by screw or by
stop ring- refer basic pump model code pos 13.

6     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Model code •

Preferred standard option
Other standard option

Open Loop Pumps


• Special option on request

X Series - LR Control

L R 0 0 0 A * * * * * 0 * 0 0 * * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Venting valve
LR – Power control • • • • • 0 – None • • • • •
26 Displacement adjustment options 1 – Solenoid valve • • • • •
0 – Not applicable Specify voltage in 39
27 28 Electronic amplifier 37 Position monitoring
00 – Not applicable 0 – Not applicable
29 Yoke displacement zone 38 Electric motor type
A – Single side of centre “A” • • • • • 0 – Not applicable
30 Additional functions 39 Control Voltage
2 – Pressure limiter • • • • • 0 – Not applicable • • • • •
3 – Load sensing and pressure limiter (standard ∆p • • • • • H – 24V DC (Preferred voltage) • • • • •
= 15 bar) B – 110V AC 50 Hz / 120V AC 60 Hz • • • • •
To select Power Control without Pressure
D – 230V AC 50 Hz / 240V AC 60 Hz • • • • •
Limiter, specify ... LR ... A2F. 40 41
Customer adjustment specification
31 Pressure control options 42 43

0 – None i.e. pilot operated with remote port (stan- • • • • • 0000 – None • • • • •
dard arrangement) **** – Eaton assigned number as per • • • • •
F – Remote port without pilot valve • • • • • data specified in table below ◊
K – Electro - proportional relief valve, • • • • • 44 45 46 Special features
complete with electronic card
L – Electro - proportional relief valve • • • • •
000 – None • • • • •
with OBE *** – Defined by Eaton • • • • •
S – Slow upstroke screw adjustment • • • • • 47 48 Design number
32 33 34 Power control specification ** – 10-99 assigned by Eaton • • • • •
*** – 3-digit value in kW at 1500 rpm • • • • • Pump Size 66 90 130 180 250
35 Pilot oil filter
0 – Not applicable ◊ Example for customer adjustment specifications A2 29 30
Pump Size 66 90 130 180 250 Special pressure adjust- Main stage Pilot valve Load
ment pressure control pressure control sense ∆p
Standard setting (bar) 20 90 15
Max. setting (bar) 40 350 40
Customer-specified adjustment
(bar) ....... ....... .......
Note: Setting must be at least 30bar.

Special max. Minimum Maximum


Displ. Adjustment displacement displacement
Standard 0 cm3/rev 100%
Customer-specified adjustment
(cm3/rev)
....... .......
Note: Special pressure adjustments and/or maximum displacment adjustments are the
most common reasons for using this option. Max. displacement adjustable by screw or by
stop ring- refer basic pump model code pos 13.

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      7
Model code •

Preferred standard option
Other standard option

Open Loop Pumps


• Special option on request

X Series - ST Control
21 = K, M or L mandatory
(HP lubrication)
22 = L mandatory
(electrical yoke position indicator)

S T * * * A * * * * * * * 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Pilot oil supply
S T – Electronic flow control by • • • • • A – Internal pilot oil supply only • • • • •
proportional valve B – External pilot oil supply only • • • • •
C – Internal + external pilot oil supply by
26 Displacement adjustment options • • • • •
check valve
C – With CETOP 3 proportional valve • • • • •
A – With CETOP 3 interface (no valve) • • • • • 37 Position monitoring
D – CETOP 3 proportional valve KBSDGV-4 with OBE • • • • • 0 – Not applicable
(electr. amplifier necessary for flow control)
38 Electric motor type
G – CETOP 3 Axis-Pro OBE valve with integr. flow • • • • •
control (no add. amplifier necessary) 0 – Not applicable
27 28 Electronic amplifier 39 Control voltage
03 – With ER9.3 amplifier card • • • • • 0 – Not applicable
05 – With DIN rail module • • • • • 40 41
00 – Without electronics • • • • • Customer adjustment specification
42 43
29 Yoke displacement zone 0000 – None • • • • •
A – Single side of centre “A” • • • • • **** – Eaton assigned number as per • • • • •
data specified in table below ◊
30 Extra functions
44 45 46 Special features
0 – Without additional options • • • • •
4 – Pressure limiter override • • • • • 000 – None • • • • •
5 – Pressure limiter and power limiter override • • • • • *** – Defined by Eaton • • • • •
31 Pressure limiter control options 47 48 Design number
0 – Including pilot relief valve • • • • • ** – 10-99 assigned by Eaton • • • • •
and remote port option Pump Size 66 90 130 180 250
F – Remote port only • • • • •
K – Proportional relief valve + • • • • • ◊ Example for customer adjustment specifications A4/A5 29 30
EEA-PAM amplifier card Special pressure Main stage Pilot valve
L – Proportional relief valve with integrated • • • • • adjustment pressure control pressure control
Electronics OBE Standard setting (bar) 20 90
32 33 34 Power control setting options Max. setting (bar) 40 350
Customer-specified
000 – No power limiter override • • • • • adjustment (bar) ....... .......
*** – 3-digit value in kW at 1500 rpm • • • • • Note: Setting must be at least 30bar.
35 Pilot oil filter
0 – Without filter • • • • • Special max. Minimum Maximum
E – Filter with electr. indicator • • • • • Displ. Adjustment displacement displacement
Pump Size 66 90 130 180 250 Standard 0 cm3/rev 100%
Customer-specified adjustment
(cm3/rev)
....... .......
Note: Special pressure adjustments and/or maximum displacment adjustments are the most common
reasons for using this option. Max. displacement adjustable by screw or by stop ring- refer basic pump
model code pos 13.

Notes:
-S T control requires a min. operation pressure of >25 bar for operation. For internal pilot oil supply it must be assured that this load pressure can be
provided. Below this min. pressure value pump will automatically go on max. stroke.
- External ST control pilot pressure needs to be equal or more than 35% of max. load pressure

8     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Model code •

Preferred standard option
Special option on request

Open Loop Pumps


X Series - FM Control

FM0 0 0 A 0 0 0 0 0 0 0 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25Control type 36 Venting valve
FM – Screw adjustment control • • • • • 0 – Not applicable
displacement range 50-100% 37 Position monitoring
26 Displacement adjustment options 0 – Not applicable
G – Not applicable 38 Electric motor type
27 28 Electronic amplifier 0 – Not applicable
00 – Not applicable 39 Control voltage
29 Yoke displacement zone 0 – Not applicable
A – Single side of centre “A” • • • • • 40 41
Customer adjustment specification
42 43
30 Additional functions
0 – Not applicable
0000 – None • • • • •
**** – Eaton assigned number as per • • • • •
31 Pressure control options data specified in table below ◊
0 – Not applicable 44 45 46 Special features
32 33 34 Power control specification 000 – None • • • • •
000 – Not applicable *** – Defined by Eaton • • • • •
35 Pilot oil filter 47 48 Design number
0 – Not applicable ** – 10-99 assigned by Eaton • • • • •
Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250

◊ Example for customer adjustment specifications


Special max. Minimum Maximum
Displ. adjustment displacement displacement
Standard 50% 100%
Customer-specified adjustment
(cm3/rev)
....... .......
Note: Special pressure adjustments and/or maximum displacment adjustments are the
most common reasons for using this option.

Notes:
- Adjustable only with load pressure ≤30 bar
- Factory setting 100%

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      9
Model code •

Preferred standard option
Other standard option

Open Loop Pumps


• Special option on request

X Series - ZP Control

Z P * * * A 0 0 0 0 0 0 * 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Pilot oil supply
ZP – Dual displacement control • • • • • A – Internal pilot oil supply only • • • • •
B – External pilot oil supply only • • • • •
26 Displacement adjustment options C – Internal + external pilot oil • • • • •
1 – 4/2 solenoid valve • • • • • supply by check valve
A – With CETOP 3 interface (no valve) • • • • • 37 Position monitoring
27 28 Electronic amplifier 0 – Not applicable
00 – Not applicable 38 Electric motor type
29 Yoke displacement zone 0 – Not applicable
A – Single side of center "A" • • • • • 39 Control Voltage
30 Extra functions 0 – Not applicable
0 – Not applicable 40 41
Customer adjustment specification
31 Pressure limiter control options 42 43
0 – Not applicable 0000 – None • • • • •
32 33 34 Power control specification
**** – Eaton assigned number as per • • • • •
data specified in table below ◊
000 – Not applicable
44 45 46 Special features
35 Pilot oil filter
000 – None • • • • •
0 – Not applicable *** – Defined by Eaton • • • • •
Pump Size 66 90 130 180 250 47 48 Design number
• • • • •
** – 10-99 assigned by Eaton
Pump Size 66 90 130 180 250

◊ Example for customer adjustment specifications


Special max. Minimum Maximum displace-
Displ. Adjustment displacement ment
Standard 0 cm3/rev 100%
Customer-specified adjustment
(cm3/rev)
....... .......
Note: Special pressure adjustments and/or maximum displacment adjustments are the
most common reasons for using this option.

Notes:
- Basic position has max. displacement (solenoid de-engerized)
- Standard setting for minimum displacement: 50%

10     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Model code •

Preferred standard option
Other standard option

Open Loop Pumps


• Special option on request

X Series - SP Control
22 = P or M mandatory
(electrical yoke position indicator)

S P * * * A * * * * * * 0 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25Control type 36 Venting valve
SP – Displacement adjustment control • • • • • 0 – Not applicable
via proportional valve 37 Position monitoring
26 Displacement adjustment options 0 – Not applicable
C – CETOP 3 proportional valve KDG4V3 • • • • • 38 Electric motor type
A – CETOP 3 interface only • • • • • 0 – Not applicable
27 28 Electronic amplifier 39 Control voltage
03 – With ER9.3 amplifier card • • • • • 0 – Not applicable
05 – With DIN rail module • • • • • 40 41
00 – Without electronics • • • • • 42 43
Customer adjustment specification
29 Yoke displacement zone 0000 – None
A – Single side of centre “A” • • • • • • • • • •
**** – Eaton assigned number as per • • • • •
30 Additional functions data specified in table below ◊
44 45 46 Special features
0 – None • • • • •
4 Pressure limiter override • • • • • 000 – None • • • • •
31 Pressure control options *** – Defined by Eaton • • • • •
47 48 Design number
0 – Including pilot relief valve • • • • •
and remote port option ** – 10-99 assigned by Eaton • • • • •
F – Remote port only • • • • • Pump Size 66 90 130 180 250
K – Proportional relief valve + • • • • •
EEA-PAM amplifier card
L – Relief valve with integrated Electronics OBE • • • • • ◊ Example for customer adjustment specifications
32 33 34 Power control specification Special pressure Main stage pressure Pilot valve
adjustment control pressure control
000 – Not applicable
Standard setting (bar) 20 90
35 Pilot oil filter Max. setting (bar) 40 350
E – Filter with electrical and visual indicator • • • • • Customer-specified adjustment
0 – None • • • • • (bar) ....... .......
V – Filter with electrical and visual indicator • • • • • Note: Setting must be at least 30bar.
Pump Size 66 90 130 180 250
Special max. Minimum Maximum
Displ. Adjustment displacement displacement
Standard 0 cm3/rev 100%
Customer-specified adjustment
(cm3/rev)
....... .......
Note: Special pressure adjustments and/or maximum displacment adjustments are the
most common reasons for using this option. Max. displacement adjustable by screw or by
stop ring- refer basic pump model code pos 13.

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      11
Model code •

Preferred standard option
Other standard option

Open Loop Pumps


• Special option on request

X Series - ES control

E S * 0 0 A 0 0 0 0 0 0 0 * * 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Venting valve
ES – Displacement adjustment control 0 – Not applicable
via electric motor • • • • •
37 Position monitoring
26 Displacement adjustment options A – 4 limit switches • • • • •
N – Electric motor, medium response • • • • • B – 8 limit switches • • • • •
M – Electric motor, fast response • • • • • P – 4 limit switches + yoke pos. • • • • •
P – Electric motor, slow response • • • • • feedback (potentiometer)
27 28 Control electronics T – 8 limit switches + yoke pos. • • • • •
feedback (potentiometer)
00 – Not applicable
38 Electric motor type
29 Yoke displacement zone
2 – Motor with brake (IP54) • • • • •
A – Single side of centre “A” • • • • • 3 – Motor without brake (explosion proof) • • • • •
30 Additional functions 39 Control voltage
0 – Not applicable
0 – Not applicable
31 Pressure control options 40 41
0 – Not applicable Customer adjustment specification
42 43
32 33 34 Power control specification 0000 – None
• • • • •
000 – Not applicable **** – Eaton assigned to number as per • • • • •
data specified in table below ◊
35 Pilot oil filter 44 45 46 Special features
0 – Not applicable 000 – None • • • • •
Pump Size 66 90 130 180 250 *** – Defined by Eaton • • • • •
47 48 Design Number
** – 10-99 assigned by Eaton • • • • •
Pump Size 66 90 130 180 250

◊ Example for customer adjustment specifications


Special max. Minimum Maximum
Displ. Adjustment displacement displacement
Standard 0 cm3/rev 100%
Customer-specified adjustment
(cm3/rev)
....... .......
Note: Special response times (see table in ES section of Control options) and/or
maximum displacement adjustments are the most common reasons for using this option

Pump size Adjustment time (sec) 26


M N P
066/090 7,5 15 38
130/180 18 35 86
250 10 20 48

12     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Model code •

Preferred standard option
Other standard option
x Not available
Open Loop Pumps
X Series - No control: 2 =F
Fixed displacement PF X Models

0 0 0 0 0 A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 66 90 130 180 250 Pump Size 66 90 130 180 250
24 25 Control type 36 Venting valve
00 – No control • • • • x 0 – Not applicable
26 Displacement adjustment options 37 Position monitoring
0 – Not applicable 0 – Not applicable
27 28 Control electronics 38 Electric motor type
00 – Not applicable 0 – Not applicable
29 Yoke displacement zone 39 Control voltage
A – Single side of center "A" • • • • x 0 – Not applicable
30 Additional functions 40 41
Customer adjustment specification
42 43
0 – Not applicable
31 Pressure control options
0000 – None • • • • x
0 – Not applicable 44 45 46 Special features

32 33 34 Power control specification 000 None • • • • x


*** Defined by Eaton • • • • x
000 – Not applicable
47 48 Design number
35 Pilot oil filter
10-99 assigned by Eaton • • • • x
0 – Not applicable **
Pump Size 66 90 130 180 250
Pump Size 66 90 130 180 250

Note: Available displacement 6 , 7 , 8 (Page 4)

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      13
Model code • Preferred standard option

Combination pump unit

P * XC - * * * * * * * * * * * * * * * * * * * * HC 8 1 * * * * * * * * * *
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39

Unit Position 1 2 3 4 Unit Position 1 2 3 4


1 Combination unit Second displacement cm3/rev
11 12 13
(in3/rev)
P – Pump • • • • – Options as first displacement •
2 Displacement
14 15 Second control type
F – Fixed • • • •
V – Variable • • • • – Options as first displacement •
3 Pump Series 16 17 18 Third displacement
X – “X” series (ex-30 design) • • • • 0 – Options as displacement •
4 Unit type 19 20 Third control type
C – Combination unit • • • • A – Options as control •
5 Separator 21 22 23 Fourth displacement

6 7 8 First displacement cm3/rev (in3/rev)


– Options as displacement •
24 25 Fourth control type
066 – 66 (4.0) •
090 – 90 (5.5) • – Options as control •
130 – 130 (7.9) • 26 27
180 – 180 (11.0) • Assembly number
28 29
250 – 250 (15.3) •
For special displacements, see basic pump model code HC81 • • • •
9 10 First control type 30 31 32
33 34 35 Assembly number
00 – No control (Fixed displacement only)
DF – Pressure compensator • 36 37 38 Defined by Eaton • • • •
LR – Power limiter control • 39
ST – Electronic flow control • Unit Position 1 2 3 4
FM – Screw adjustment flow control •
ZP – Dual displacement control •
Unit Position 1 2 3 4

X- Series Open Loop Pumps

Form Page
The 48-digit coding system has or special features ( 44 to 46 ) Explanation for each character Codes
been developed to identify all are needed, please provide the
configuration options for the “X” information when ordering.
Basic Pump Model Code 1 to 23
series (Open Loop) fixed and
For combination units, you may Control Options 24 to 39
variable displacement pumps.
need to provide an additional
The Model Code lets you specify
model code. In such a case, each Customer Adjustment Specification 40 to 43
a unit with the desired features.
single pump section must be
All 48 digits must be present Special Features 44 to 46
specified separately using this or
when ordering.
other Eaton catalog information.
You may wish to photocopy the Where characters are already
Design Number 47 & 48
matrix below to ensure that each stated in the blank Model Code,
number is entered in the correct there is no option available.
Combination Units Model Code 1 to 39
box. If adjustments other than
the standard setting ( 40 to 43 )

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
P X –
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

14     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump specifications
Metric

Model 66 90 130 180 250


Design Swashplate – Axial piston pump
Type of mounting Flange or foot-mounted - Combination units foot mounted only
Pipe connection Flange
ISO 6162-1 (SAE J518 code 61) B psi P38M (1 1/2” - 500) P51M (2” - 500) P64M (2 1/2” - 500) P64M (2 1/2” - 500) P89M (3 1/2” - 500)
ISO 6162-2 (SAE J518 code 62) A P25M (1” - 6000) P25M (1” - 6000) P25M (1” - 6000) P32M (1 1/4” - 6000 P32M (1 1/4” - 6000)
Direction of rotation Clockwise, Counterclockwise on request
Mounting attitude Horizontal, other mounting options are available on request
Ambient temperature range min -20
ºC
max 50
Weight M kg 55 75 106 114 212
Moment of inertia J kg m2 0.016 0.016 0.045 0.045 0.146

Hydraulic characteristics
Rated pressure (100% duty cycle) pN bar 350
Inlet pressure p1min 0.85 abs 0.85 abs 0.95 abs 0.95 abs 1.0 abs
bar
p1max 10 10 10 10 10
Max. pressure to ISO 5598:2008 p2max bar 420
Hydraulic fluid Hydraulic oil to DIN 51524 part 2
See fluid recommendations in application data
Hydraulic fluid temperature range min -25 (on start up)
ºC
max 90
Viscosity range for continuous operation min 10
cSt
max 75
Maximum permissible start viscosity max cSt 1000
Cleanliness ISO 4406 18/15/13
Maximum geometric Vg cm3/rev 66 90 130 180 250
displacement
Speed range min 150
rev/min
max 1800
Case pressure (over pressure) pcase bar
n = 1200 rev/min 3.5 3.5 3.2 3.2 2.8
n = 1500 rev/min 2.7 2.7 2.5 1.5 2.1
n = 1800 rev/min 2.2 1.2 2.0 2.0 1.7
The differential between case pressure and inlet pressure should not exceed 0,5 bar.

Drive
Driving torque M1single Nm 367 501 724 1002 1392
(pN = 350 bar,Vg at 1500 rev/min, η = 100%)
Power consumption P1single kW 57,8 78,8 113,8 157,5 218,8
(pN = 350 bar, n = 1500 rev/min, η = 100%)

Combination units
Maximum driving torque limited to M1Comb. Nm 2x367 2x501 2x724 2x1002 2x1392
splined shaft only - comb. unit

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      15
Pump specifications
US

Model 66 90 130 180 250


Design Swashplate – Axial piston pump
Type of mounting Flange or foot-mounted - Combination units foot mounted only
Pipe connection Flange
ISO 6162-1 (SAE J518 code 61) B psi P38M (1 1/2” - 500) P51M (2” - 500) P64M (2 1/2” - 500) P64M (2 1/2” - 500) P89M (3 1/2” - 500)
ISO 6162-2 (SAE J518 code 62) A P25M (1” - 6000) P25M (1” - 6000) P25M (1” - 6000) P32M (1 1/4” - 6000 P32M (1 1/4” - 6000)
Direction of rotation Clockwise, Counterclockwise on request
Mounting attitude Horizontal, other mounting options are available on request
Ambient temperature range Min -4
ºF
Max 122
Weight M Ib 121 165 234 251 467
Moment of inertia J Ib ft2 0.38 0.38 1.068 1.068 3.465

Hydraulic characteristics
Rated pressure (100% duty cycle) pN psi 5000
Inlet pressure p1min 12,3 12,3 13,8 13,8 14,5
psi
p1max 145 145 145 145 145
Max. pressure to ISO 5598:2008 p2max psi 6000
Hydraulic fluid Hydraulic oil to DIN 51524 part 2
See fluid recommendations in application data
Hydraulic fluid temperature range min -13 (on start up)
ºF
max 194
Viscosity range for continuous operation min 10
cSt
max 75
Maximum permissible start viscosity max cSt 1000
Cleanliness ISO 4406 18/15/13
Maximum geometric Vg in3 4.0 5.5 8.0 11.0 15.3
displacement
Speed range min 150
rev/min
max 1800
Case pressure (overpressure) pcase psi
n = 1200 rev/min 50 50 46 46 40
n = 1500 rev/min 39 39 36 36 30
n = 1800 rev/min 32 32 29 29 24
The differential between case pressure and inlet pressure should not exceed 3,625 psi.
Drive
Driving torque M1single Ibf ft 271 369 534 739 1027
(pN = 5075psi,Vg at 1500 rev/min, η = 100%)
Power consumption P1single hp 77.5 105.5 152.5 211 293
(pN = 5075psi, n = 1500 rev/min, = 100%)

Combination units
Maximum driving torque limited to M1Comb. Ibf ft 2x271 2x369 2x534 2x739 2x1027
splined shaft only - comb. unit

16     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Performance curves
066 & 090 Series

Power efficiency performance curve Theoretical bearing lifetime


Size 066 Size 066

Pump size 066


100 200
100% η vol
105
Input power P1 (kW)
Input torque (Nm)
100%
80 50%

25% -1
η tot (%) 1000 min

Basic rating life L10 [h]


60 -1
1500 min
in
/m

100
in

1800 min-1
rev

v/m

104
00

40
re
18

00
15
η=

η=

3
20 40 3 x 10
bar 50 100 200 300 400
20
0 0 psi 725 1450 2900 4350 5800
P2 (bar) 0 100 200 300 350 Operating pressure
P2 (psi) 0 1500 2900 4350 5076

Power efficiency performance curve Theoretical bearing lifetime


Size 090 Size 090

Pump size 090


100 100% η vol 200
105
Input power P1 (kW)

100%
Input torque (Nm)

50%
80
Basic rating life L10 [h]

-1
η tot (%) 25% 1000 min

60 -1
1500 min
in
/m

100
in
rev

v/m

1800 min-1
00

40 104
re
18

00
15
η=

η=

20 40
3x103
20 bar 50 100 200 300 400
0 0
P2 (bar) 0 100 200 300 350
psi 725 1450 2900 4350 5800
P2 (psi) 0 1500 2900 4350 5076
Operating pressure

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      17
Performance curves
130 & 180 Series

Power efficiency performance curve Theoretical bearing lifetime


Size 130 Size 130

Pump size 130


100 100% η vol 200 105
Input power P1 (kW)

100%
Input torque (Nm)

80 50% -1
1000 min

Basic rating life L10 [h]


25% -1
η tot (%) 1500 min

60
1800 min -1
in
/m

100
in
rev

v/m

4
10
00

40
re
18

00
15
η=

η=

20 40 3
3 x 10
20 bar 50 100 200 300 400
0 0
P2 (bar) 0 100 200 300 350 psi 725 1450 2900 4350 5800
P2 (psi) 0 1500 2900 4350 5076 Operating pressure

Power efficiency performance curve Theoretical bearing lifetime


Size 180 Size 180

Pump size 180


5
100 100% η vol 200 10
Input power P1 (kW)

100%
Input torque (Nm)

80 50%
Basic rating life L10 [h]

-1
25% 1000 min
η tot (%)

60 1500 min-1
in
/m

100
1800 min-1
in
rev

v/m

104
00

40
re
18

00
15
η=

η=

20 40
3x103
20 bar 50 100 200 300 400
0 0
P2 (bar) 0 100 200 300 350 psi 725 1450 2900 4350 5800
P2 (psi) 0 1500 2900 4350 5076
Operating pressure

18     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Performance curves
250 Series

Power efficiency performance curve Theoretical bearing lifetime


Size 250 Size 250

Pump size 250


100 200 10
5
100% η vol
100% Input power P1 (kW)
50% Input torque (Nm)
80

Basic rating life L10 [h]


25% -1
η tot (%) 1000 min

60 1500 min -1
in
/m

100
in

1800 min -1
rev

v/m

104
00

40
re
18

00
15
η=

η=

20 40 3
3x10
20 50 100 200 300 400 bar
0 0 725 1450 2900 4350 5800 psi
P2 (bar) 0 100 200 300 350
Operating pressure
P2 (psi) 0 1500 2900 4350 5076

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      19
Installation and start-up

Warning Fluid Cleanliness


Care should be taken that mechanical and hydraulic resonances are Hydrokraft pumps are rated in anti-wear petroleum fluids with a
avoided in the application of the pump. Such resonances can seri- contamination level of 18/15/13 per ISO 4066. Operation in fluids
ously compromise the life and/or safe operation of the pump. with levels more contaminated than this is not recommended.
Fluids other than petroleum, severe service cycles, or temperature
Drive Data extremes are cause for adjustment of these codes. Please contact
your Eaton Representative for specific duty cycle recommendation.
Mounting attitude should be horizontal using the appropriate case
drain ports to ensure that the case remains full of fluid at all times. Eaton Hydrokraft pumps, as with any variable displacement piston
Consult your local Eaton Representative if a different arrangement pumps, will operate with apparent satisfaction in fluids up to the
is required. In those cases where geometric tolerances of mounting rating specified here. Experience has shown however, that pump
are critical, or where specific tolerance ranges are required and not and hydraulic system life is not optimized with high fluid contamina-
specified, consult Eaton Engineering for specific limits. tion levels (high ISO cleanliness codes).
Direction of shaft rotation, viewed from the prime mover end, must Proper fluid condition is essential for long and satisfac tory life of
be as indicated in the model designation on the pump – either right hydraulic components and systems. Hydraulic fluid must have the
hand (clockwise) or left hand (counterclockwise). Direct coaxial correct balance of cleanliness, materials, and additives for protection
drive through a flexible coupling is recommended. If drives impos- against wear of components, elevated viscosity and inclusion
ing radial shaft loads are considered, please consult your Eaton of air.
Representative.
Essential information on the correct methods for treating hydraulic
Start-up Procedure fluid is included in Eaton publication 561 "Eaton Guide to Systemic
Make sure the reservoir and circuit are clean and free of dirt/debris Contamination Control" available from your local Eaton distributor.
prior to filling with hydraulic fluid. Fill the reservoir with filtered oil In this publication, filtration and cleanliness levels for extending the
and fill to a level sufficient enough to prevent vortexing at the life of axial piston pumps and other system components are listed.
suction connection to pump inlet. It is good practice to clean the Included is an excellent discussion of the selection of products
system by flushing and filtering, using an external slave pump. needed to control fluid condition.

Caution
Before the pump is started, fill the case through the uppermost
drain port with hydraulic fluid of the type to be used. The case drain
line must be connected directly to the reservoir and must terminate
below the oil level. Once the pump is started, it should prime within
a few seconds. If the pump does not prime, check to make sure that
there are no restrictions between the reservoir and the inlet to the
pump, and that the pump is being rotated in the proper direction,
and that there are no air leaks in the inlet line and connections. Also
check to make sure that trapped air can escape at the pump outlet.
After the pump is primed, tighten the loose outlet connections, then
operate for five to ten minutes (unloaded) to remove all trapped air
from the circuit. If the reservoir has a sight gage, make sure the fluid
is clear – not milky.

20     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Application Data and
Fluid Recommendations

Fluid Type DIN/ISO Rated Maximum Speed (rev/min) Recommended Maximum Bearing Life
Classification Pressure pN Seal Material Operating Tem-
(bar) 130 & 180 cm 250 &360 cm
3 3
500 & 750 cm
3
perature (ºC)
Water Glycol HFC 250 1800 1500 1250 NBR 45 25-100%
HFDR (phosphate ester based) HFDR 350 1500 1200 1000 FKM 60 100%
HFDU (glycol based) HFDU 350 1500 1200 1000 FKM 60 100%
HFDU (ester based) HFDU 350 1800 1500 1250 FKM 60 100%
HEES (synthetic ester) HEES 350 1800 1500 1250 FKM 60 100%
See general specifications for speed limitation depending on displacement.
For HFC operation, bearing flushing is mandatory. Highest speed only recommended at optimized application conditions.
Use Model Code 21 = "C" for seal option, and contact your Eaton Representative for validation.
Seal material can differ on an individual pump depending on specific seal function.
Bearing life with HFC fluid depends significantly on fluid temperature, cleanliness, quality, flushing and application parameters.
Typical values vary between 25% and 100% compared to mineral oil.
Only fluids with fully saturated esters (iodine value <10) should be used.
HFDU and HEES fluids can be used at full ratings, but need to be monitored continuosly to maintain quality and performance. The following
important values should always be checked:
- Water content (<= 500 ppm)
- Fluid cleanliness (18/15/13 per ISO 4406)
- TAN value (no significant change from new oil)
- Viscosity (no significant change from new oil)
- Additives (no significant change from new oil)
Under harsh operation conditions, especially with regard to temperature and water content, ester-based HFDU and HFDR fluids are prone
to hydrolysis, the resulting chemical processes and products of which could damage seals and other pump components. In general, the susceptibili-
ty to temperature and contamination is significantly higher than with standard mineral oils.
In line with Eaton Germany GmbH T&C warranty conditions covering use of HFDR/HFDU/HEES fluids, fluid-related damage is excluded.

Case/Bearing Flushing Vertical Mounting High pressure lubrication /


Case and bearing flushing are Vertical mounting of Hydrokraft Hydrostatic Balancing for Yoke
mandatory for HFC fluid pumps is possible, but venting Bearings (half-cup bearings)
operation, and recommended for and lubrication of shaft bearings High-pressure bearing lubrication
all other conditions where the can require special flushing and and balancing (Model Code For details and additional
pump is operating for longer installation procedures. For 21 = "K") is recommeded for information, please refer to the
intervals at low pressure i.e. details, please refer to the operating conditions with either "Hydrokraft Application Guideline
<20 bar (<300 psi) and/or low Hydrokraft Application Guideline high cycle frequencies (very Presentation" available from your
flow at high pressure Presentation available from your short up/downstroke times) Eaton Representative.
(compensated mode). Eaton Representative. and/or where the swashplate is
constantly maintained at a Eaton
Estimated Flushing Flow Hydraulics Group EMEA
certain angle for long periods of
Values at 1500 rev/min Hydrokraft plant
time (compensated mode).
Pump Size Flushing Flow Am Joseph 16
(cm3/rev) (l/min) D-61273 Wehreim Germany
Tel: +49(0)6081103-324/-286/-235
066/90 4/5,5
Fax: +49(0)6081103-342
130/180 7,5/11 Mail: Hydrokraft@eaton.com
250 15

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      21
Pump dimensions
PVXS-066
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

Pressure
0 120 185 246 compensator
pilot stage
Pressure
68 X1* compensator
main stage
8 17 L1*

L1* L1*
Stroke limiter
L 50%...100%
of Vmax 320
41.0
Ø40.8 93
CW Ref.(229)
18

Centre bore 90
DIN 332-D
M12
26 4x M10-20
L2* deep B 176
58 35 150 210

302
X

L1* A

Ø125h8

10h9

MA* Ø38k6

L1* L3* B
Visual position indicator
274
351
160
235

27.8 M12-18 Deep 35.7 M12-18 Deep A – System pressure port ISO L3 – Oil filling 7/8" - 14 UNF or
6162-2 P25M (SAE J518 CODE Bleed plug
62-1" - 6000 PSI)
Ø25 Ø38 MA – Gauge port system
57.2 B – Inlet port ISO 6162-1 P38M
69.8 pressure G1/4"
(SAE J518 CODE 61 - 1 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M22x1.5 (According
Port A 12.5 Deep
Port B to mounting position use
View X
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

22     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-066
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)

Pressure
comensator
0 120 185 pilot stage
Pressure
X1* comensator
68 main stage
8 17 L1*

L1* L1*
Stroke limiter
L 50%...100%
of Vmax 320
Centre bore 93
CW
DIN 332-D M12 Ref.(229)
18

90

26 4x M10-20
L2* Deep 176
58 35 150 210

292

L1*

Ø125h8

W40x1.25x10a
DIN 5480

A
B
MA*

L1* L3*
274
351
40 40
160
210

27.8 M12-18 Deep 35.7 M12-24 Deep A – System pressure port ISO L3 – Oil filling 7/8" - 14 UNF or
6162-2 P25M (SAE J518 CODE Bleed plug
62-1" - 6000 PSI)
MA – Gauge port system
Ø25 Ø38 B – Inlet port ISO 6162-1 P38M
57.2 69.8 pressure G1/4"
(SAE J518 CODE 61 - 1 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M22x1.5 (According
12.5 Deep
to mounting position use
Port A Port B
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      23
Pump dimensions
PVXS-090
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

Pressure
0 120 185 246 compensator
pilot stage
Pressure
X1* compensator
68
main stage
8 17 L1*
Stroke limiter L1* L1*
50...100%
L of Vmax
320
93
CW Ref.(229)
41.0
ø40.8 18

Centre bore 90
DIN 332-D M12

B
4x M10-20 176
L2* 26 Deep 210
58 35 150

325
X
L1* A

Ø125h8

10h9

MA*
Ø38k6

L1* L3* B
Visual position indicator
160 274
142.5 117.5 351

27.8 M12-21 deep 77.77 M12-24 deep


Ø51 A – System pressure port ISO L3 – Oil filling 7/8" - 14 UNF or
6162-2 P25M (SAE J518 CODE Bleed plug
Ø25 62-1" - 6000 PSI)
57.2 MA – Gauge port system
42.88 B – Inlet port ISO 6162-1 P51M
pressure G1/4"
(SAE J518 CODE 61 - 2"
3000 PSI) X1 – Remote port pressure compen-
sator G 1/4"-
Port A L1 – Drain port M22x1.5 (According
12.5 Deep
View X Port B to mounting position use
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

24     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-090
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)

Pressure
0 120 185 compensator
pilot stage
X1* Pressure
68 compensator
main stage
8 17 L1*
Stroke limiter L1 L1*
50...100%
L of Vmax
320
Centre bore 93
DIN 332-D M12 CW
Ref.(229)
18

90

4x M10-20
L2* 26 Deep 176
58 35 150 210

292

L1

W 40x1.25x10a
DIN 5480

Ø125h8
B A
MA*

L1* L3*
274
351

44 44
160
210

27.8 M12-20 deep 42.88 M12-24 deep


A – System pressure port ISO L3 – Oil filling 7/8" - 14 UNF or
6162-2 P25M (SAE J518 CODE Bleed plug
Ø31 62-1" - 6000 PSI)
Ø25 77.77 MA – Gauge port system
57.2 B – Inlet port ISO 6162-1 P51M
pressure G1/4"
(SAE J518 CODE 61 - 2"
3000 PSI) X1 – Remote port pressure compen-
sator G 1/4"-
Port B L1 – Drain port M22x1.5 (According
Port A 12.5 Deep
to mounting position use
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      25
Pump dimensions
PVXS-130
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

Pressure
0 148 229 316 compensator
pilot stage
X1*
Pressure
92 compensator
9 20 L1* main stage

L1 L1*
Stroke limiter
50...100%
of Vmax
CW 377
117
Ref.(229)
54.0 22
53.0
Centre bore
DIN 332-D M12 113

4x M12-26 220
L2* 32 Deep B 260
40
185
82

325 X
306

L2 A

MA* Ø50k6
2x M20-30
DEEP
14h9
Ø160.000
159.937

200
L1* L3* B
224
265 Visual Position indicator
391
471

27.8 M12-20 deep 50.8 M12-20 deep


A – System pressure port ISO L3 – Oil filling 1 1/16" - 14 UNF or
6162-2 P25M (SAE J518 CODE Bleed plug
62-1" - 6000 PSI)
Ø25 Ø63 MA – Gauge port system
57.2 B – Inlet port ISO 6162-1 P64M
88.9
pressure G1/4"
(SAE J518 CODE 61 - 2 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M26x1.5 (According
Port A 12.5 Deep
Port B to mounting position use
View X
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

26     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-130
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)

Pressure
compensator
0 148 pilot stage
229
X1* Pressure
compensator
78 main stage
9 20 L1*
Stroke limiter L1 L1*
L 50...100%
of Vmax
377
Centre bore 117
DIN 332-D M16 CW
Ref.(287)
B 22

113

4x M12-26 200
L2* 32 Deep 260
68 40 185

318

L1

Ø160h8
W50x1.25x
30x38x10a
DIN 5480

A
B
MA*

L1* L3*
341
421

50 65
200
260

27.8 M12-20 deep 50.8 M12-20 deep


A – System pressure port ISO L3 – Oil filling 1 1/16" - 14 UNF or
6162-2 P25M (SAE J518 CODE Bleed plug
Ø63 62-1" - 6000 PSI)
Ø25 MA – Gauge port system
57.2 88.9 B – Inlet port ISO 6162-1 P64M
pressure G1/4"
(SAE J518 CODE 61 - 2 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M26x1.5 (According
Port A Port B 12.5 Deep
to mounting position use
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      27
Pump dimensions
PVXS-180
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

Pressure
compensator
0 148 229 316 pilot stage
X1* Pressure
92 compensator
9 20 L1* main stage L1 L1*
Stroke limiter
L 50...100%
of Vmax
377
117 Ref.
CW
(287)
54.0 22
53.8
Centre
bore DIN 113
332-D M16

L2* 4x M12-26 B
32 deep
82 40 185 220
260
325

306
L1 A

Ø160h8

MA*
2x M20-30 deep

14h9

Ø50 k6

200
224 L1* L3* B
265 Visual position indicator
391
471

31.8 M14-22 deep 50.8 M12-20 deep A – System pressure port ISO L3 – Oil filling 1 1/16" - 14 UNF or
6162-2 P32M (SAE J518 CODE Bleed plug
Ø63 62-1 1/4" - 6000 PSI)
Ø32 MA – Gauge port system
66.7 B – Inlet port ISO 6162-1 P64M
88.9
pressure G1/4"
(SAE J518 CODE 61 - 2 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M26x1.5 (According
Port A 12.5 Deep
Port B to mounting position use
View X
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

28     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-180
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)

Pressure
compensator
0 148 229 pilot stage
X1* Pressure
78 compensator
9 20 L1* main stage L1
L1*
Stroke limiter
50...100%
L of Vmax
377

Centre bore 117 CW


DIN 332-D Ref.
M16 (287)
B 22

113

4x M12-26
L2* 32 deep
68 40 185 200
260
318

L1

Ø160h8
W50x1.25x30
A 38x10a
B DIN 5480
MA*

50 65
200
260
L1* L3*
341
421
31.8 M14-20 deep 50.8 M12-20 deep
A – System pressure port ISO L3 – Oil filling 1 1/16" - 14 UNF or
6162-2 P32M (SAE J518 CODE Bleed plug
Ø32
Ø63 62-1 1/4" - 6000 PSI)
66.7 88.9 MA – Gauge port system
B – Inlet port ISO 6162-1 P64M
pressure G1/4"
(SAE J518 CODE 61 - 2 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M26x1.5 (According
Port A Port B 12.5 Deep
to mounting position use
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      29
Pump dimensions
PVXS-250
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = R (A & B ports radial)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

Pressure
0 187 281 403 compensator
pilot stage
116 X1*
Pressure
9 25 L1* compensator L1 L1*
main stage
Stroke limiter
L
50...100%
of Vmax
448
146 CW
Ref.
(357)
69.0 26
68.8

Centre bore
DIN 332-D 140
M20
4x M16-32
L2* 41 deep B
105 50 230
276
362
350

x
L1 A MA*

Ø200h8
MA

2x M24-38
deep
18 h9

Ø65 k6

250
280 Visual position L1* L3*
330 B
indicator
505
598

31.8 M14-24 deep 69.9 M16-32 deep


A – System pressure port ISO L3 – Oil filling 1 5/16" - 14 UNF or
6162-2 P32M (SAE J518 CODE Bleed plug
Ø32
Ø89 62-1 1/4" - 6000 PSI)
MA – Gauge port system
66.7 120.7 B – Inlet port ISO 6162-1 P89M
pressure G1/4"
(SAE J518 CODE 61 - 3 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
Port A L1 – Drain port M33x2 (According to
Port B 12.5 Deep
View X mounting position use
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

30     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Pump dimensions
PVXS-250
Options illustrated:
16 = 1 (A & B ports SAE, metric Thread)
17 = A (A & B ports axial)
18 19 = 02 (Splined shaft)
22 = 0 (no position indicator)
24 25 = DF control (pressure compensator)

Pressure
0 187 281 compensator
pilot stage
91 X1* Pressure
25 L1* compensator
main stage L1 L1*
Stroke limiter
50...100%
of Vmax
448
Centre bore 146 CW
Ref.
DIN 332-D (357)
M20 26

140

4x M16-32
L2* 41 deep
80 50 230 276
350
362

L1

Ø200h8
W62x1.25x30
x48x10a
A DIN 5480
B
4 MA

96 70
250
325 L1* L3*
429
522

31.8 M14-25 deep 69.8 M16-26 deep A – System pressure port ISO L3 – Oil filling 1 5/16" - 14 UNF or
6162-2 P32M (SAE J518 CODE Bleed plug
62-1 1/4" - 6000 PSI)
Ø89 MA – Gauge port system
Ø32 B – Inlet port ISO 6162-1 P89M
66.7 120.7 pressure G1/4"
(SAE J518 CODE 61 - 3 1/2"
500 PSI) X1 – Remote port pressure
compensator G 1/4"-
L1 – Drain port M33x2 (According to
12.5 Deep
Port B mounting position use
Port A
upper port) ...* Connection with plug
L2 – M18x1.5-12 Deep
supplementary drain or bleed
plug. Must be drained in
addition to L1 if the pump is
installed with the shaft input
end pointing upwards.

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      31
Control Options DF

General Description flow rate. System pressure can


Energy-saving hydraulic drives be set manually, hydraulically
are possible with pressure or electronically.
compensated and/or power The standard Hydrocraft
controlled pumps, especially pressure compensator is pilot
in combination with the operated, has a remote port
loadsensing option. and is very stable.
Control options DF
System pressure remains
constant for the entire volume

DF000A00

DF000A010 DF000A0F DF000A0S

DF000AA DF000AB DF000A0_ _ _ _ _100H

32     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options DF
A0

213 70
31 Pressure compansator
pilot stage 45
Pressure compansator
main stage

X1* 91
41

Ref. dim. for


size 66-250

93
X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP
...* Connection with plug.

4
T P

X1

D1 D2 3
P A T X1

MA
A

A – System port
B – Inlet port
1
L1, L2 – Drain port
L3 – Oil filling plug
B L2 L3 L1
MA – Gauge port-system pressure
X1 – Remote port pressure
compensator
1 – Basic pump
2 – Connection plate for DF-control
3 – Pressure compensator,
main stage
4 – Pressure compensator,
pilot stage

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      33
Control Options DF
A10

Pressure compansator 65
213
pilot stage
31 45
Pressure compansator
main stage

X1*

Load sensing valve 131

X2* 82

41

Ref. dim. for


size 66-250

X1 Remote port pressure comensator. G 1/8’’-12.5 DEEP

X2 Remote port load sensing. G 1/8’’ 93


...* Connection with plug.

5
T P
X1

D2
D1 4
P X1 A T A1

X2

(By customer)
D3
3
P A T X1

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
2 MA – Gauge port-system pressure
MA X1 – Remote port
pressure compensator
A X2 – Remote port load sense
1 – Basic pump
2 – Connection plate for DF-control
3 – Pressure compensator-load
1 B L1 L2 L3 sense stage
4 – Pressure compensator
main stage
5 – Pressure compensator
pilot stage

34     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options DF
A0F

174 70
31 Pressure comensator 45
main stage
X1*
53

Ref. dim for


size 66-250

X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP 93


...* Connection with plug.

4
T P

X1

D1 D2 3

P A T X1

MA

A – System port
B – Inlet port
L1, L2 – Drain port
1
L3 – Oil filling plug
B L2 L3 L1 MA – Gauge port-system pressure
X1 – Remote port
pressure compensator
1 – Basic pump
2 – Connection plate for DF-control
3 – Pressure compensator,
main stage
4 – Closing plate

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      35
Control Options DF
A0S

237 70
54 45
Pressure
compensator
pilot stage
Slow upstroke
adjustment Pressure X1* 91
screw compensator
main stage 41

Ref. dim. for


size 66-250

X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP


93
...* Connection with plug.

T P

X1

D1 D2
3
P A T X1

MA
A – System port
A B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port
1
pressure compensator
B L2 L3 L1
1 – Basic pump
2 – Connection plate for DF-control
3 – Pressure compensator,
main stage with slow upstroke
adjustment screw
4 – Pressure compensator,
pilot stage

36     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options DF
AA

233 70
90 46

Solenoid valve

Pressure compensator
pilot stage (2-pressure level)

Pressure compensator 161


main stage
X1* 81
41

Ref. dim for


size 66-250

X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP


...* Connection with plug.
93

A B 5

P T

4
A B TP

X1

D1 D2 3
P A T X1

A – System port
B – Inlet port
2 L1, L2 – Drain port
MA L3 – Oil filling plug
MA – Gauge port-system pressure
A
X1 – Remote port
pressure compensator
1 – Basic pump
1 2 – Connection plate for DF-control
B L2 L3 L1 3 – Pressure compensator,
main stage
4 – Pressure compensator,
pilot stage (Dual relief function)
5 – 4/2 Directional control valve

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      37
Control Options DF
AB

233 70
90 46

Solenoid valve

Pressure compensator
pilot stage (2-pressure level)
175
Pressure compensator
main stage
X1*
81
41

Ref. dim for


size 66-250

X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP


...* Connection with plug.

A B
a b 5
P T

4
A B TP

X1

D2
3
P A T X1

A – System port
2 B – Inlet port
L1, L2 – Drain port
MA
L3 – Oil filling plug
A
MA – Gauge port-system pressure
X1 – Remote port
pressure compensator
1 1 – Basic pump
B L2 L3 L1 2 – Connection plate for DF-control
3 – Pressure compensator
main stage
4 – Pressure compensator
pilot stage (Dual relief function)
5 – 4/3 Directional control valve

38     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options DF
A0_ _ _ _ _100H

268
86 134
Pressure compensator
pilot stage
Venting valve

154
Pressure compensator 124
main stage
X1* 74
41

Ref. dim for


size 66-250

X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP


...* Connection with plug. 93

A B
6 5
T P
D3 D4
4
B A T P

X1

D1 D2 3
P A T X1

A – System port
B – Inlet port
2 L1, L2 – Drain port
MA L3 – Oil filling plug
A
MA – Gauge port-system pressure
X1 – Remote port
pressure compensator
1 – Basic pump
1 2 – Connection plate for DF-control
B L2 L3 L1 3 – Pressure compensator,
main stage
4 – Intermediate plate
5 – Pressure compensator,
pilot stage
6 – Venting valve

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      39
Control Options LR

General Description The power hyperbola can be Maximum pump flow can be This solution is also
Energy-saving hydraulic drives continuously adjusted between limited mechanically to between recommended for severe
are possible with pressure Pmin and Pmax, Pmin is given by the 50% and 100% by a screw. As operating conditions and the
compensated and/or power minimum setting of the control an additional option, maximum need for high repeatability over a
controlled pumps, especially main stage (20bar approx.) and (or minimum) flow can also be long period of time. The setting
in combination with the power loss of the pump. limited by a spacer inside the must be defined before ordering
loadsensing option. control cylinder (Model Code since it cannot be modified
Both controller types can be position 13 options 4, 5 or 6, in operation.
LR controls combined with another or with in combination with customer
additional options; for available adjustment specified in positions
The typical p/Q curve is a options, see Model Code.
hyperbola. For constant speed, 40 to 43 ).
the drive torque, i.e. the power
used, is held constant.

PVX-066-180-LR000A20 PVX-066-180-LR000A30 PVX-066-180-LR000A2F

PVX-250-LR000A20 PVX-250-LR000A30 PVX-250-LR000A2F

40     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options LR
A20 size 066-180

213
143 70
31 Pressure compensator 45
pilot stage
Pressure and power
compensator main
stage
X1* 91

41

Power compensator
pilot stage
82

Ref. dim. for


size 66-180

162
X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP
...* Connection with plug.

T P

X1

D2
D1 3
P A T X1

X1

A – System port
5 B – Inlet port
L1, L2 – Drain port
MA 2 L3 – Oil filling plug
MA – Gauge port-system pressure
A
X1 – Remote port pressure com-
pensator

1 1 – Basic pump
2 – Connection plate for LR-control
B L2 L3 L1
3 – Pressure and power
compensator main stage
4 – Pressure compensator
pilot stage
5 – Power compensator pilot stage

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      41
Control Options LR
A20 size 250

213
143 70
31 Pressure compensator
pilot stage 45
Pressure and power
compensator main stage

X1* 91
41

Power compensator
pilot stage

106
357

Ref. dim. for


size 66-180

194
X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP
...* Connection with plug.

T P

X1

D2
D1 3
P A T X1

X1

5
A – System port
MA 2 B – Inlet port
L1, L2 – Drain port
A L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure com-
pensator

1 1 – Basic pump
2 – Connection plate for LR-control
B L2 L3 L1
3 – Pressure and power
compensator main stage
4 – Pressure compensator pilot
stage
5 – Power compensator pilot stage

42     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options LR
A2F size 066-180

174
143 70
Pressure and
31 power compensator 45
main stage
X1*
53

Power compensator
pilot stage
82

Ref. dim. for


size 66-180

162

X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP


...* Connection with plug.

4
T P

X1

D2 3
D1
P A T X1

X1

MA 2

A – System port
B – Inlet port
L1, L2 – Drain port
1 L3 – Oil filling plug
MA – Gauge port-system pressure
B L2 L3 L1 X1 – Remote port pressure
compensator
1 – Basic pump
2 – Connection plate for LR-control
3 – Pressure and power compensa-
tor main stage
4 – Closing plate
5 – Power compensator pilot stage

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      43
Control Options LR
A2F size 250

174
143 70
31 Pressure and power 45
compensator main stage

X1*
53

Power compensator
pilot stage
106

357

Ref. dim. for


X1 Remote port pressure comensator. G 1/4’’-12.5 DEEP 194 size 66-180
...* Connection with plug.

4
T P

X1

D2 3
D1
P A T X1

X1

MA 2 A – System port
A B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure
1 compensator

B L2 L3 L1 1 – Basic pump
2 – Connection plate for LR-control
3 – Pressure and power
compensator main stage
4 – Closing plate
5 – Power compensator pilot stage

44     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options LR
A30 size 066-180

213
143 Pressure compensator 65
pilot stage 45
31
Pressure and power
compensator main stage
Load sensing valve

X1 131
X2* 82
41
Power compensator
pilot stage

82

Rim. dim. for


size 66-180

162

X1 Remote port pressure comensator 8S ACC. DIN EN ISO 8434-1


X2 Remote port load sensing. G 1/8”
...* Connection with plug.

5
TP

X1

4
D2
D1
P X1 AT A1

X2

(By customer) A – System port


D3 B – Inlet port
3
P A T X1 L1, L2 – Drain port
X1 L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure com-
T pensator
X2 – Remote port load sense
1 – Basic pump
6
2 – Connection plate for LR-control
MA 2
3 – Pressure compensator-load
A sense stage
4 – Pressure and power compensa-
tor main stage
5 – Pressure compensator
pilot stage
1 B L1 L2 L3 6 – Power compensator pilot stage

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      45
Control Options LR
A30 size 250

213
143 Pressure compensator 65
31 pilot stage 45
Pressure and power
compensator main stage

Load sensing valve


X1 131

X2* 82
41
Power compensator
pilot stage

106

Ref. dim. for


194 size 66-180
X1 Remote port pressure comensator 8s ACC. DIN EN ISO 8434-1
X2 Remote port load sensing. G 1/8’’
...* Connection with plug.

5
TP

X1

D2 4
D1
P X1 A T A1

X2

(By customer)
D3
3
P A T X1
X1 A – System port
B – Inlet port
L1, L2 – Drain port
T L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure com-
pensator
6
X2 – Remote port load sense
MA 2
1 – Basic pump
A
2 – Connection plate for LR-control
3 – Pressure compensator-load
sense stage
4 – Pressure and power compensa-
1 B L1 L2 L3 tor main stage
5 – Power compensator pilot stage
6 – Power compensator pilot stage

46     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST

General Description signal to apply the required an additional option, of time. The setting must be
The energy-saving setting, resulting in a maximum (or minimum) flow defined before ordering since it
electrohydraulic displacement highly accurate dynamic can be set by a spacer inside cannot be modified in operation.
control type ST efficiently control system. the control cylinder (Model ST control will replace old SP
adjusts pump output by acting Hysteresis is approximately 1% Code position 13 , options control type for PVX pumps.
on the swashplate within of end value. The ST control can 4, 5 or 6, in combination with
customer adjustment specified ST-control requires a min.
electrically adjustable limits. The also be combined with operation pressure of
swashplate angle value is fed hydromechanical relief valves for in positions 40 to 43 ).
>25 bar for operation. Below
back to the controller unit via an pressure and/or power control. This solution is recommended this min. pressure value
electrical closed loop system. Maximum pump flow can be for severe operating conditions pump will automatically go on
A proportional valve and servo limited mechanically to between and the need for high max. displacement.
piston use the controller output 50% and 100% by a screw. As repeatability over a long period

STC03A00 STC03A40 STC03A4F STC03A4K

STC03A4K_ _ _ _C STC03A4B STC03A4L

STC03A50 STC03A5F STC03A5K STC03A5L

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      47
Control Options ST
STC03A00

258
129 46

Proportional control valve


86

Ref. dim. for


size 66-250

75

A B

3
P T

P A T B

A
MA

1
A – System port
B L2 L3 L1 B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
1 – Basic pump
2 – Connection plate
3 – Proportional control valve

48     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A40

258
46
117

Proportional control valve

X1*
Pressure limiter
override pilot stage Pressure limiter
171
override main stage
85

Ref. dim. for


size 66-250

X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP 77


257
...* Connection with plug.

A B
6
P T
P A T B

3
5

P T D1
A 4
D2
T
P
X1
PA T X1 X1

A – System port
B – Inlet port
2 L1, L2 – Drain port
L3 – Oil filling plug
A MA – Gauge port-system pressure
MA X1 – Remote port pressure
limiter override
1 – Basic pump
1 2 – Connection plate
B L2
3 – Connection plate for ST-control
L3 L1
4 – Pressure limiter override
main stage
5 – Pressure limiter override
pilot stage
6 – 4/3 Directional control valve
7 – Proportional control valve

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      49
Control Options ST
STC03A4F

258
117 46

Proportional control valve

X1*
171
Pressure limiter
override main stage
85

Ref. dim. for


size 66-250

77
X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP 228
...* Connection with plug.

A B
6
P T
P A T B
3

T P D1
A 4
D2
T
P
X1
P A T X1 X1

A – System port
2 B – Inlet port
L1, L2 – Drain port
A
MA L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure
limiter override
1 1 – Basic pump
B L2 L3 L1 2 – Connection plate
3 – Connection plate for ST-control
4 – Pressure limiter override
main stage
5 – Closing plate
6 – Proportional control valve

50     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A4K

258
117 46

Proportional control valve

X1*
Propotional 171
relief valve Pressure limiter
override main stage
85

Ref. dim for


size 66-250

77
X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP 228
...* Connection with plug.

A B
6
P T
P A T B
3
5

T P D1
A
4
D2
T
P
X1
P A T X1 X1

A – System port
B – Inlet port
2 L1, L2 – Drain port
L3 – Oil filling plug
A MA – Gauge port-system pressure
MA
X1 – Remote port pressure
limiter override
1 – Basic pump
1 2 – Connection plate
B L2 L3 L1 3 – Connection plate for ST-control
4 – Pressure limiter override
main stage
5 – Proportional relief valve
6 – Proportional control valve

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      51
Control Options ST
STC03A4K_ _ _ _C

258
117 46

XP

X1* 211
Propotional
relief valve Pressure limiter override
125
main stage
85

XP External pilot pressure(option VIA no retun valve)10L ACC. DIN EN ISO 8434-1
77
X1 Remote port pressure limiter override. G 1/4”-12.5 Deep 228
...* Connection with plug.

A B
6
P T
P A T B
7 Xp

P A T B
5 3

T D1

4
D2
P
X1 A – System port
P A T X1 X1
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure
limiter override
XP – External pilot pressure
2
1 – Basic pump
A 2 – Connection plate
MA 3 – Connection plate for ST-control
4 – Pressure limiter override
main stage
5 – Proportional relief valve
1 6 – Proportional control valve
B L2 L3 L1
7 – Adaptor block for pilot
oil option

52     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A4B

298
157 46

Pressure limiter
override pilot stage Proportional control valve
(2-pressure level)

4/3 Directional X1*


control valve 171
Pressure
limiter
override 85
main stage

Ref. dim. for


size 66-250

X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP


96
...* Connection with plug. 247

A B
7
P T
6 5 P A T B

B 3
b

B T
T P D1
A P
A
4
a A D2
P
X1
P A T X1 X1

A – System port
A
B – System
Inlet portport
L1,
B L2 – Drain port
Inlet port
L1, L2
L3 – Drain
Oil portplug
filling
MA
L3 – Gauge port-system
Oil filling plug pressure
2 MA
X1 – Gauge port-system
Remote port pressurepressure
A X1 – limiter
Remoteoverride
port pressure
MA limiter override
1 – Basic pump
21 – Basic pump plate
Connection
32 – Connection plate for ST-control
43 – Connection
Pressure andplate
powerfor limiter
ST-control
1 4 – override
Pressure main stage limiter
and power
B L2 L3 L1 5 – Pressure limiter
override main override pilot
stage
5 – stage
Pressure(Duel reliefoverride
limiter function)pilot
6 – stage
4/3 (Duel relief
Directional function)
control valve
76 – Proportional
4/3 Directional control valve
control valve
7 – Proportional control valve

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      53
Control Options ST
STC03A4L

258
117 46

Proportional control valve

X1*
Pressure limiter
override pilot stage 171
Pressure
(Proportional limiter
relief valve) override main 85
stage

Ref. dim. for


size 66-250

77
X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP 257
...* Connection with plug.

A B
6
P T
P A T B

3
5

T P D1
A 4
D2
T
P
X1
PA T X1 X1

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
2
MA – Gauge port-system pressure
A X1 – Remote port pressure
MA limiter override
1 – Basic pump
2 – Connection plate
3 – Connection plate for ST-control
B
4 – Pressure limiter override
L2 L3 L1
main stage
5 – Pressure limiter override
pilot stage (Proportional relief
valve + OBE)
6 – Proportional control valve

54     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A50

258
117 46

Proportional control valve

X1*
Pressure
limiter override Pressure and 171
pilot stage power limiter
override main stage 85
Power limiter
override pilot stage

72

Ref. dim. for


size 66-250
X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP 162
341
...* Connection with plug.

A B
7
P T
P A T B

5 3

T P
D1
A 4

D2
T
P
X1
P A T X1 X1 A – System port
X1
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
T
X1 – Remote port pressure
6 limiter override
1 – Basic pump
2 – Connection plate
A 2 3 – Connection plate for ST-control
MA 4 – Pressure and power limiter
override main stage
5 – Pressure limiter override
pilot stage
1 6 – Power limiter override
B
pilot stage
L2 L3 L1
7 – Proportional control valve

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      55
Control Options ST
STC03A5F

258

117 46

Proportional control valve

X1*
171
Pressure and power limiter
override main stage
85

Power limiter
override pilot stage

72

Ref. dim. for


size 66-250
X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP 162

...* Connection with plug.

312

A B
7
P T
P A T B
5 3

T P D1
A
4
D2
T
P
A – System port
X1
P A T X1 X1 B – Inlet port
X1 L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
T X1 – Remote port pressure
6 limiter override
1 – Basic pump
2 – Connection plate
A 2
MA 3 – Connection plate for ST-control
4 – Pressure and power limiter
override main stage
5 – Closing plate
1 6 – Power limiter override
B L2 L3
pilot stage
L1
7 – Proportional control valve

56     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ST
STC03A5K

258

117 46

Proportional control valve

Proportional X1*
relief valve 171
Pressure and power
limiter override
main stage 85

Power limiter
override pilot stage

72

Ref. dim. for


size 66-250
162

X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP


312
...* Connection with plug.

A B
7
P T
P A T B

5 3

T P D1
A 4
D2
P T
X1 A – System port
P A T X1 X1
B – Inlet port
X1
L1, L2 – Drain port
L3 – Oil filling plug
T MA – Gauge port-system pressure
6 X1 – Remote port pressure
limiter override
1 – Basic pump
A 2 2 – Connection plate
MA
3 – Connection plate for ST-control
4 – Pressure and power limiter
override main stage
1 5 – Proportional relief valve
6 – Power limiter override
B L2 L3 L1
pilot stage
7 – Proportional control valve

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      57
Control Options ST
STC03A5L

258
117 46

Proportional control valve

X1*
Pressure limiter
171
override pilot stage Pressure and power
(Proportional limiter override
relief valve) 85
main stage
Power limiter
override pilot stage

72

Ref. dim. for


size 66-250
162
X1 Remote port pressure limiter override. G 1/4’’-12.5 DEEP
...* Connection with plug. 337

A B
7
P T
P A T B

5 3

P D1
A 4
D2
P T
X1
PA T X1 X1
X1
A – System port
B – Inlet port
T L1, L2 – Drain port
6 L3 – Oil filling plug
MA – Gauge port-system pressure
X1 – Remote port pressure
A 2 limiter override
MA
1 – Basic pump
2 – Connection plate
1
3 – Connection plate for ST-control
4 – Pressure and power limiter
B L2 L3 L1 override main stage
5 – Pressure limiter override pilot
stage (Proportional relief
valve + OBE)
6 – Power limiter override
pilot stage
7 – Proportional control valve

58     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options FM

General Description (position number 13 in model operation. FM-control is


FM The FM - control is a coding, options 4, 5 or 6 in replacing old-style FE and HG
displacement control where the combination with customer control. Please be aware that
pump flow can be manually adjustment specifications adjustment of screw is only
adjusted by a screw. The position 40-43 for the set possible with load pressure
maximum (and/or minimum) values). The setting must be below ca. 30 bar.
flow can be limited by a spacer defined before ordering and
inside the control cylinder cannot be modified during

FM000A0

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      59
Control Options FM
FM000A0

77
23 45

37

Ref. dim. for


size 66-250

93

3
P A T X1

MA

A – System port
B – Inlet port
1 L1, L2 – Drain port
L3 – Oil filling plug
B L2 L3 L1
MA – Gauge port-system pressure
1 – Basic pump
2 – Connection plate for FM-con-
trol
3 – Adaptor plate

60     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ZP

General Description 13 in model coding, options (with solenoid de-energized),


ZP The ZP-control is a 4, 5 or 6 in combination with and 50% of displacement with
dual-displacement control where customer adjustment solenoid activated. Other
the pump flow can be adjusted specifications position 40-43 for adjustments need to be defined
to two different positions by a the set values). The setting must by customer adjustment
solenoid valve. The maximum be defined before ordering and specification code.
(and/or minimum) flow can be cannot be modified during
limited by a spacer inside the operation. Standard setting will
control cylinder (position number be max. displacement

ZP100A0

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      61
Control Options ZP
ZP100A0

155 46

42

Directional control valve

Stroke speed adjustment 125


control valve

39

Ref. dim. for


size 66-250

93

A 4

P T

P A T B 3

MA

A
A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Oil filling plug
1 MA – Gauge port-system pressure
B L2 L3 L1 1 – Basic pump
2 – Connection plate for ZP-control
3 – Stroke speed adjustment
control valve
4 – Directional control valve

62     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options SP

General Description A proportional valve and As an additional option, This solution is recommended
The energy-saving servo piston use the controller maximum (or minimum) flow for severe operating conditions
electrohydraulic displacement output signal to apply the can be set by a spacer inside and the need for high
control type SP efficiently required setting, resulting the control cylinder (Model Code repeatability over a long period
adjusts pump output by acting in a highly accurate dynamic position 13 , options 4, 5 or 6, of time. The setting must be
on the swashplate within control system. in combination with customer defined before ordering since it
electrically adjustable limits. The adjustment specified in positions cannot be modified in operation..
Hysteresis is approximately 1% 40 to 43 ).
swashplate angle value is fed of endProportional
value. The SP control Filter with el.
back to the controller unit via an can also be valve
control combined with and optical
electrical closed loop system. contamination
hydromechanical relief valves for
indicator
pressure control.

Pilot pressure
relief valve

A B C

066 291 407 501


090 291 407 501
130 352 463 647
180 352 463 647
250 217 534 813

SPC03A
C
Proportional Filter with el.
control valve and optical
contamination
indicator A

A B
6 Pilot pressure
P T relief valve
A P T B

2
1 5
3
B
A P T B
4

A P T B
A MA T1
Pst1

Mst

A
EATON Hydrokraft 3
W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      63

Pst2
A B
6
2 P T
A
Control Options SP
SPC03A

A B A – System port
6
P T B – Inlet port
A P T B L1, L2 – Drain port
L3 – Oil filling plug
2
1 5 MA – Gauge port-system pressure
3
Pst1 – Ports for pilot pump B
A P T B Pst2 – Pilot pump outlet port
4 Mst – Gauge port- pilot pressure
A P T B T1 – Return line of control circuit
T1 (optional)
A MA
Pst1 S – Inlet of pilot pump

Mst 1 – Basic pump


2 – Pilot pump
3 – Connection plate for SP-control
4 – Pilot pressure relief valve
5 – Pilot oil filter
6 – Proportional control valve
3

Pst2

2
A

B L2 L3 L1

64     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Control Options ES
Available to special order only.

General Description A potentiometer for stepless with the result that once the
This unit is used for flow adjustment and/or position control is specified and built,
adjustment. It has a 3-phase monitoring is also available. response time are not variable in
electric servo-motor, worm- Response times from zero to operation. Explosion Protection
gear and a switchbox with 4 or maximum depend on the ratio versions are also available.
(optional) 8 limit switches for selected and on the (fixed)
speed of the servo-motor, No Pressure/Power
different positions. Limiter possible!

A B C

066 291 407 501


090 291 407 501
130 352 463 647
180 352 463 647
250 217 534 813
ESN00A00

Electric motor for


displacement control
B

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      65

2
Control Options ES Electric motor for

ESN00A00
displacement control
B

A – System port
B – Inlet port
M
L1, L2 – Drain port
L3 – Oil filling plug
MA – Gauge port-system pressure
2
1 – Basic pump
2 – Electric motor and limit switch
for ES-control

MA

B L2 L3 L1

66     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
General Dimensions
PFXS-066
Options illustrated:
12 = R (Clockwise rotation)
14 15 = 00 (No thru drive)
18 19 = 01 (ISO keyed shaft)
22 = 0 (No yoke position indicator)
24 25 = 00 (Without control)

0 26 120 246

16
68
8 L1.1* B

CW

223

41.0 18 160
40.8

Centre bore
Din 332-D M12 80

4X M10- 20 176
Deep

58 35 150

210

L2* L1 L3* A

MA*
10h9

125.000
Ø124.937

Ø38K6

120 L1.1*
B
175 274
299

A – System pressure port ISO 6162-2 L2 – Ventilation port for vertical


27.8 35.7 P25M (SAE J518 CODE 62-1" - mounting G 1/4"- (Shaft upward)
M12-18 Deep
M12-18 Deep 6000 PSI) L3 – Oil filling plug M26 x 1.5
B – Inlet port ISO 6162-1 P38M (SAE MA – Gauge port system pressure
J518 CODE 61 - 1 1/2" 500 PSI) G 1/4"
Ø25 Ø38
L1 – Drain port M26 x 1.5 (According to ...* – Connection with plug
57.2 69.8 mounting position use upper port)
L1.1 – Drain port 7/8"-14 UNF
(According to mounting position
use upper port)
Port A Port B
View X

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      67
General Dimensions
PFXS-090
Options illustrated:
12 = R (Clockwise rotation)
14 15 = 00 (No thru drive)
18 = 01 (ISO keyed shaft)
22 = 0 (No yoke position indicator)
24 25 = 00 (Without control)

0 26 120 247

16
68
8 L1.1* B

CW
223

41.0 18 160
40.8

Centre bore 80
Din 332-D
M12

4X M10- 20 176
Deep
210
58 35 150

218

L2* L1 L3* A

MA*
10h9
125.000
Ø124.937

Ø38K6

120
L1.1* B
112.5 87.5 275
305

A – System pressure port ISO 6162-2 L2 – Ventilation port for vertical


P25M (SAE J518 CODE 62 - 1" - mounting G 1/4"-
27.8 M12-18 Deep 77.8 M12-25 Deep 6000 PSI) (Shaft upward)
B – Inlet port ISO 6162-1 P51M (SAE L3 – Oil filling plug M26 x 1.5
Ø51 J518 CODE 61- 2 - 500PSI MA – Gauge port system pressure
Ø25
L1 – Drain port M26x1.5 (According to G 1/4"
57.2 42.9 mounting position use ...* – Connection with plug
upper port)
L1.1 – Drain port 7/8"-14 UNF
(According to mounting position
use upper port)
Port A Port B
View X

68     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
General Dimensions
PFXS-130
Options illustrated:
12 = R (Clockwise rotation)
14 15 = 00 (No thru drive)
18 = 01 (ISO keyed shaft)
22 = 0 (No yoke position indicator)
24 25 = 00 (Without control)

0 32 148 229 316

19
92 L3*

B
CW

L1 263
54.0 22 200
53.8

Drain port 100


Centre bore
Din 332-D G 1/4”
M16
220
4x M12-20
Deep
260
82 40 185

306 A

MA*

14h9
Ø160.000
159.937
Ø50K6

150 L2* L1* L3* B


265 391

413

A – System pressure port ISO 6162-2 L2 – Ventilation port for vertical mount-
50.8 M12-20 Deep P25M (SAE J518 CODE 62-1" - ing G 1/4"-(Shaft upward)
27.8 M12-20 Deep 6000 PSI) L3 – Oil filling plug 1 1/6"-12UNF
B – Inlet port ISO 6162-1 P64M (SAE MA – Gauge port system pressure
Ø63 J518 CODE 61 - 2 1/2" 500 PSI) G 1/4"
Ø25
L1 – Drain port M26 x 1.5 (According to ...* – Connection with plug
57.2 88.9
mounting position use upper port)

Port A Port B
View X

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      69
General Dimensions
PFXS-180
Options illustrated:
12 = R (Clockwise rotation)
14 15 = 00 (No thru drive)
18 = 01 (ISO keyed shaft)
22 = 0 (No yoke position indicator)
24 25 = 00 (Without control)

0 32 148 229 316

19
92 L3*
9
B
CW

L1
263
54.0 22 200
53.8

Centre bore Drain port 100


Din 332-D G 1/4”
M16

4x M12-20 220
Deep
260
82 40 185

306 A

MA*

14h9
Ø160.000
159.937
Ø50K6

150 L2* L1* L3* B


265 391

413

50.8 M12-20 Deep A – System pressure port ISO 6162-2 L2 – Ventilation port for vertical
31.8 M14-22 Deep
P32M (SAE J518 CODE 62 - 1 mounting G 1/4"- (Shaft upward)
1/4" - 6000 PSI) L3 – Oil filling 1 1/16"- 12 UNF
Ø63 B – Inlet port ISO 6162-1 P64M (SAE MA – Gauge port system pressure
Ø32 J518 CODE 61 - 2 1/2" 500 PSI) G 1/4"
66.7 88.9
L1 – Drain port M26 x 1.5 (According to ...* – Connection with plug
mounting position use upper port)

Port A Port B
View X

70     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Thru-Drive Options
060 and 090 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting interface.
Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.

Option illustrated:
14 15 = 0A (SAE A)
9T 16/32 DP
2x M10-20 DEEP

82.62
Ø 82.58

12
106.4 34
47

Option illustrated:
14 15 = 0B (SAE B)
13T 16/32 DP

2x M12-THRU

101.65
Ø 101.62

13
146 22
46
102

Option illustrated:
14 15 = 0C (SAE C)
14T 12/24 DP

2x M16-30 DEEP

127.05
Ø 127.02

181 13
61 17
98

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      71
Thru-Drive Options
130 and 180 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting interface.
Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.

Option illustrated:
14 15 = 0A (SAE A)
9T 16/32 DP
2x M10-20 DEEP

82.62
Ø 82.58

12
106.4 34
47

Option illustrated:
14 15 = 0B (SAE B)
13T 16/32 DP

2x M12-THRU

101.65
Ø 101.62

13
146 22
46
102

Option illustrated:
14T 12/24 DP
14 15 = 0C (SAE C)
2x M16-30 DEEP

127.05
Ø 127.02

181 13
61 17
98

72     EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020
Thru-Drive Options
250 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting interface.
Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.

Option illustrated:
14 15 = 0A (SAE A)

2 x M10 -18 DEEP 9T 16/32 DP

82.62
Ø82.58

9
106.4
28

32

Option illustrated:
14 15 = 0B (SAE B)
6 x M12 -25 DEEP 13T 16/32 DP

101.65
Ø101.62

89.8 12

146 16

47

EATON Hydrokraft W-Series Open Loop Piston Pumps E-PUIO-CC008-E September 2020      73
Eaton Eaton Eaton
Hydraulics Group USA Hydraulics Group Europe Hydraulics Group Asia Pacific
14615 Lone Oak Road Route de la Longeraie 7 Eaton Building
Eden Prairie, MN 55344 1110 Morges 4th Floor, No. 3 Lane 280 Linhong Rd
USA Switzerland Changning District
Tel: 952-937-9800 Tel: +41 (0) 21 811 4600 Shanghai 200335
Fax: 952-294-7722 Fax: +41 (0) 21 811 4601 China
www.eaton.com/hydraulics Tel: (+86 21) 5200 0099
Fax: (+86 21) 5200 0400

© 2020 Eaton Corporation


All Rights Reserved
Document No. E-PUIO-CC008-E
September 2020

You might also like