Professional Documents
Culture Documents
Technical Catalog
TVW
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Code
Form Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Basic Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ES Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DP Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SP Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SM Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Special Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Combination Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Examples for Combination units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Pump Specifications
US . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Metric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Performance Curves
130 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
180 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
250 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
360 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
500 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
750 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Hydraulic Transmission Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
With Charge Flow Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Without Charge Flow Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Combination of Two Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Controls
Electric Motor Displacement Control ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Controls for Position/Displacement DP, SP, SM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Pressure Signal Displacement Control DP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Example for TVW... - DP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Proportional Valve Displacement Control SP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Control Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SP Control with Pressure and Power Limitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Servo Adjustment Displacement Control with Mechanical Feedback SM . . . . . . . . . . . . . . . . . . . . 33
Pump Dimensions
TVWS 130/180 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
TVWS 250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
TVWS 360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
TVWS 500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
TVWS 750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Control Dimensions
TVWS 250/360/500/750 ES Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
TVWS 130/180 SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
TVWS 250/360/500/750 SP Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
TVWS 130/180 DP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
TVWS 250/360/500/750 DP Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
TVWS 130/180 SM Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
TVWS 250/360/500/750 SM Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
TVWS Position of Center Gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
TVWS... Swash Angle/Flow Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Fluid Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
AVAILABLE DISPLACEMENT
• Axial piston pumps • Special design for • Through drive enable SIZES
with swash plate closed loop multiple pump
design for reliable application. installation from a 130 ccm
operation and long life. • Oversize shaft and single shaft. Multiple 180 ccm
• Rotating and pressure shaft bearings. pump combinations
are also available. 250 ccm
loaded parts are • Standard available
pressure balanced. • Pressure up to 420 360 ccm
transmission circuits 500 ccm
• Wide range of available with integrated valves bar. Rated speed up to
integrated charge and and filters to build 1800 rpm. Higher 750 ccm
pilot pressure pump complete closed loop speeds possible.
combinations for single system. For charge • Large charge flow
and combination units. flow and flushing. rates for low system
temperature.
• Fast response times.
Shaft
"W" Series
Form Page
The following 55-digit coding system has been In the model code string below some characters are
developed to identify all of the configuration options already filled out and shown on this and the
for the "W" Series Transmission (Closed Loop) following pages. For such characters there is no
pumps. Use this model code to specify a unit with option available.
the desired features. All 55-digits must be present Explanation for each character can be found as
when ordering. You may want to photocopy the follows:
matrix below to ensure, that each number is entered CHARACTER PAGE
in the correct box. If adjustments other than the
standard settings (character 47...50) or special Basic Pump Model Code 1.......27 6
features (character 51...53) are needed, please Control Options 28.....46 7 - 10
provide the information when ordering. At the end of Customer Adjustment Specification 47.....50 7 - 10
this section you may need to provide an additional Special Features 51.....53 11
model code if a combination unit is needed. In case Design Number 54.....55 11
of a combination unit, each single pump section Combination Model Code 1..... 39 12
must be specified separately using this or other
Eaton catalog information.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
T V W – M 1 R S V
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55
1 0
T V W * — * * * M * * * * * * * * 1 R * * S V * * * * #
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
E S * 0 0 * 0 0 0 0 0 0 0 0 0 0 * * * * * * * #
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51
ES – Electric motor 0 – Not available 2 – Motor with brake (IP54) Adjustment Specification
displacement control 3 – Motor without brake 0000 – None
36 37 38 39 40 41
Power (Explosion proof)
30 Displacement Control Options ???? – Yes (final number will
Adjustment Options 46 Control Voltage of Zero be assigned by Eaton.
000000 – Not required Specify on table
M – Electric Motor - Fast Position Valve and
below)
response 42 Pilot Oil Filter Directional Control Valve
N – Electric Motor - Medium 0 – Not required 0 – Not applicable
response 51 Special Features - Add
B – 110 AC 50 Hz/120 AC
P – Electric Motor - Slow 43 Fail Safe Valve 60 Hz special feature description
response 0 – Not required D – 220 AC 50 Hz/240 AC (characters 51...55) on page
60 Hz 11 if required.
31 32 Electronic Controls 44 Position Monitoring G – 12 VDC
00 – Not required A – 4 limit switches H – 24 VDC
CUSTOMER ADJUSTMENT SPECIFICATIONS UNIT STANDARD SETTING CUSTOMER ADJUSTMENT OPTION REMARKS
D P * 0 0 * * * * * * * * * * 0 0 0 * * * * * #
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51
S P * * * * * * * * * * * * * * 0 0 * * * * * #
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51
CUSTOMER ADJUSTMENT SPECIFICATIONS UNIT STANDARD SETTING CUSTOMER ADJUSTMENT OPTION REMARKS
S M 0 0 0 * * * * * * * * * 0 0 0 0 0 * * * * #
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51
CUSTOMER ADJUSTMENT SPECIFICATIONS UNIT STANDARD SETTING CUSTOMER ADJUSTMENT OPTION REMARKS
"W" Series -
Special Features
* * * 1 0
51 52 53 54 55
51 52 53 Special Features
000 - None
*** - Defined by Eaton
54 55 Design Number
10 - Design Number
* * * C — * * * * * * * * * * * * * * * * * * * *
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
H C 8 1 * * * * * * * * * *
26 27 28 29 30 31 32 33 34 35 36 37 38 39
Example 1: Combination
of two closed loop pumps
Model Code Front Unit TVWF-500M08R0000H1R02SVMA20SPC03C00000000E100H000000010
Model Code Rear Unit TVWR-250M07R000PP1R02SVMA20SPC03C00000000E100H000000010
Model Code Combination Unit TVWC-500SP250SP0000000000HC81**********
Example 2: Combination
of one closed loop - and
two open loop pumps
(For open loop model code
refer to the according
catalog)
Mode Code Front Unit TVWF-500M08R0000H1R02SVMA20SPC03C00000000E100H000000010
Model Code Middle Unit PVWM-250M07R00E1R02SV0ADF000A0000000000000000010
Model Code Rear Unit PFXR-130M02R00P1A02SV0A00000A0000000000000000010
Model Code Combination Unit TVWC-500SP250DF1300000000HC81**********
MODEL TVW 130 TVW 180 TVW 250 TVW 360 TVW 500 TVW 750
HYDRAULIC CHARACTERISTICS
Displacement charge pump Vg Sp in3 2.44 2.44 3.91 4.88 7.63 12.2
Charge pressure pN Sp psi 145/290 145/290 145/290 145/290 174/290 232/348
Input pressure charge & pilot pump pmin Sp/St psi 11.6 absolute
Displacement pilot pump Vg St in3 0.5
Pilot pressure pSt psi 870 870 870 870 1160 1160
DRIVE
Max. driving torque - single unit M1 Single lb.ft. 642 888 1232 1774 2463 3688
(p2 max., h= 100%)
Max. power consumption - single unit P1 Single hp 220 304 422 608 845 10551
(p2 max., h= 100%; n= 1800 rpm)
Max. driving torque - comb. unit M1 Comb. lb.ft. 2x642 2x888 2x1232 2x1774 3688 3688
1) TVW - 750 at 1800 rpm reduced to 38.1 in3
2) When pressure below 1450 psi and flow below 25% of max. flow
MODEL TVW 130 TVW 180 TVW 250 TVW 360 TVW 500 TVW 750
HYDRAULIC CHARACTERISTICS
DRIVE
Max. driving torque - single unit M1 Single Nm 870 1204 1670 2405 3340 5000
(p2 max., h= 100%)
Max. power consumption - single unit P1 Single kW 164 227 315 454 630 7871
(p2 max., h= 100%; n= 1800 min-1)
Max. driving torque - comb. unit M1 Comb. Nm 2x870 2x1204 2x1670 2x2405 5000 5000
1) TVW - 750 at 1800 min-1 reduced to 625cm3
2) When pressure below 100 bar and flow below 25% of max. flow
60
PowerP1P1[kw]
100
n=1800 rpm
104
Input
40
p1at n=1500 rpm
20 40
103
0 0
p2 bar 50 100 200 300 400
p 2 bar 0 100 200 300 400 725 1450 2900 4350 5800
p2 psi
p 2 psi 0 1450 2900 4350 5800
60
p at n=1800 rpm
1
Input Power P1 [kw]
100
p1 at n=1500 rpm
40 104
n=1500 rpm
n=1800 rpm
20 40
103
0 0
p2 bar 0 100 200 300 400
p2 psi 0 1450 2900 4350 5800 p2 bar 50 100 200 300 400
p2 psi 725 1450 2900 4350 5800
80
V=V max
η tot for 25% Vg 105
60
Input Power P1 [kw]
200
n=1500 rpm
p1 at n=1800 rpm
40 104 n=1800 rpm
p1 at n=1500 rpm
20
103
0 0
p 2 bar 0 100 200 300 400 p 2 bar 50 100 200 300 400
p 2 psi 0 1450 2900 4350 5800 725 1450 2900 4350 5800
p 2 psi
60 300
p1 at n=1800 rpm
Input Power P1 [kw]
20 100
103
0 0
p 2 bar 0 100 200 300 400 p 2 bar 50 100 200 300 400
p 2 psi 0 1450 2900 4350 5800 p 2 psi 725 1450 2900 4350 5800
60 300
Input Power P1 [kw]
104
40 200
p1at n=1500 rpm n=1500 rpm
p1at n=1800 rpm n=1800 rpm
20 100
103
0 0
p 2 bar 0 100 200 300 400 p 2 bar 50 100 200 300 400
p 2 psi 0 2900 4350 p 2 psi 725 1450 2900 4350 5800
1450 5800
60 600
Input Power P1 [kw]
20 200
103
0 0
p2 bar 0 100 200 300 400 p 2 bar 50 100 200 300 400
p2 psi 0 1450 2900 4350 5800 p 2 psi 725 1450 2900 4350 5800
(V )
V
max
3
CONTROL
A St B St T p St
p St1
MSt
L5
L3
L3.1
2
A B L1/L2 p ac1 MSp L4 L6 MB S
Acumulator recommended
in case of short pressure
build up time
A, B System port L4 Return line charge MSp Gauge port charge pSt2 Pilot pump outlet
ASt, BSt Control flow pressure port
L1, L2 Drain port L5 Oil filling plug MSt Gauge port pilot S Suction port for
L6 Return line charge pressure charge and pilot
L3 Ventilation port for pump
vertical mounting flow pac1 Accumulator port
MA, MB Gauge port system pSp1, pSp2 Port for external T Tank port
L3.1 Air bleeding port for
vertical mounting pressure charge flow
pSt1 Port for pilot flow
pSt Port for pilot flow to
control
A St B St T p St
p St1
6.1
MSt
2.3 2.4
2.1 2.2
3.2
1.1 3.1
L5
L3
L3.1 2.1
1 2 3 7
A, B System port MA, MB Gauge port system S Suction port for 2.4 Clogging indicator
ASt, BSt Control pressure charge and pilot for charge flow filter
MSp Gauge port charge pump 3 Flushing block
L1, L2 Drain port
pressure T Tank port 3.1 Low pressure relief
L3 Ventilation port for
vertical mounting MSt Gauge port pilot 1 Basic pump valve
pressure 1.1 High pressure relief 3.2 Flushing flow
L3.1 Air bleeding port for
vertical mounting pac1 Accumulator port valve shuttle valve
L4 Return line charge pSp1, pSp2 Port for external 2 Charge block 6 Manifold
flow charge flow 2.1 Charge check valve 6.1 Pilot pressure relief
L5 Oil filling plug pSt1 Port for pilot flow 2.2 Charge pressure valve
L6 Return line charge pSt Port for pilot flow to relief valve 7 Charge/pilot pump
flow control 2.3 Charge flor filter
pSt2 Pilot pump outlet
port
2.4
Items 2.3 & 2.4
p St provided by customer
A St B St T
p St1 2.3
6.1
MSt
6
p Sp1 p Sp2 p St2
2.1 2.2
3.2
1.1 3.1
L5
L3
L3.1 2.1
1 2 3 7
A, B System port MA, MB Gauge port system S Suction port for 3 Flushing block
ASt, BSt Control pressure charge and pilot 3.1 Low pressure relief
MSp Gauge port charge pump valve
L1, L2 Drain port
pressure T Tank port 3.2 Flushing flow
L3 Ventilation port for
vertical mounting MSt Gauge port pilot 1 Basic pump shuttle valve
pressure 1.1 High pressure relief 6 Control Manifold
L3.1 Air bleeding port for
vertical mounting pac1 Accumulator port valve 7 Charge/pilot pump
L4 Return line charge pSp1 Port for external 2 Charge block (option)
flow charge flow 2.1 Charge check valve
L5 Oil filling plug pSt1 Port for pilot flow 2.2 Charge pressure
L6 Return line charge pSt2 Pilot pump outlet relief valve
flow port
2.2 2.2
2.1 3.2 2.1 3.2
1.1 3.1 1.1 3.1
2.1 2.1
1 2 3 1 2 3
A, B System port MA, MB Gauge port system pSt2 Pilot pump outlet 2.2 Charge pressure
A ,B
St St Control pressure port relief valve
L1, L2 Drain port MSp Gauge port charge S Suction port for 3 Flushing block
pressure charge and pilot 3.1 Low pressure relief
L3 Ventilation port for pump
vertical mounting MSt Gauge port pilot valve
pressure T Tank port 3.2 Flushing flow
L3.1 Air bleeding port for
vertical mounting pac1 Accumulator port 1 Basic pump shuttle valve
L4 Return line charge pSp1 Port for external 1.1 High pressure relief 6 Control manifold
flow charge flow valve 6.1 Pilot pressure relief
L5 Oil filling plug pSp2 Charge pump outlet 2 Charge block valve
pump 2.1 Charge check valve
L6 Return line charge
flow pSt1 Port for pilot flow
100%
cw
servo motor
off
0
ccw
100%
The output flow of the A separate pilot oil For exchange with: The pressure
pump is proportional to circuit is necessary with Pressure limiting valve proportional adjustment
the pilot pressure. Each pmin 60/80 bar, QSt = 12 (mechanical or can also be supplied
of the two pilot ports is l/min (3.17 USgpm). proportional) from P to T with a pressure and/or
responsible for an output From this the control line and throttle in P line power limitation.
flow direction. pressure is reduced to 0,8 Dia. (0.03)
the desired set value by
means of a suitable
circuit.
+100%
Pilot pressure
40 bar 30 20 10
10 20 30 40 bar
Pilot pressure
-100%
M St
P T
p St1
A B
pSt
A L B S
(T)
(p)
P A
11 B A R B
p T A B 4xG1/4"
p T MSt
A B
XB XA
8.1 8.1
8 ASt B St T p St
p St 2.3 2.4
MSt p Sp1 p Sp2 p St2
6.1 MA
2.1 2.2
9.1 9.1 3.1 3.2
2.1
1 2 1.1 3
L5 L3 L3.1 A B L1/L2 p ac1 MSp L4 L6 MB S
A, B System port MA, MB Gauge port system S Suction port for 2.3 Filter
ASt, BSt Control pressure charge and pilot 2.4 Clogging indicator
MSp Gauge port charge pump
L1, L2 Drain port 3 Flushing block
pressure T Tank port
L3 Ventilation port for 3.1 Low pressure relief
vertical mounting MSt Gauge port pilot XA, XB Pilot port pressure valve
pressure control
L3.1 Air bleeding port for 3.2 Flushing flow shuttle
vertical mounting pac1 Accumulator port 1 Basic pump valve
L4 Return line charge pSp1 Port for external 1.1 High pressure 6 Control manifold
flow charge flow relief valve
6.1 Pilot pressure relief valve
L5 Oil filling plug pSt1 Port for pilot flow 2 Charge block
7 DP-Control
L6 Return line charge pSt1.1 Port for pilot flow 2.1 Charge check valve
8.1 Pressure limiter 100 to
flow pSt2 Pilot pump outlet 2.2 Charge pressure 350 bar
port relief valve
EATON Vickers Hydrokraft Transmission Piston Pumps V-PUPI-TM002-E February 2003 29
Controls –
Proportional Valve
Displacement
Control SP
MSt
A B
Electrohydraulic servo
adjustment SP
The electro hydraulic
displacement control will
operate a hydrostatic -100 %
drive in all four quadrants
and work without
throttle losses within
electrically adjustable
limits. This is done by
controlling delivery flow
swash plate angle
feedback
A B L1/L2
PROPORTIONAL VALVE
CONTROL CONTROL RESPONSE
NOMINAL FLOW PRESSURE PST ELECTRONICS TIME UNIT SIZE SERVO PISTON VOLUME
L/MIN AT ∆P 0 < > VMAX DIAMETER STROKE
(USGPM) BAR (PSI) BAR (PSI) [MS] CM3 (IN3) MM (IN) MM (IN) CM3 (IN3)
Medium 12 (3.17) 10 (150) 60 (870) ER 9.3 -10 250 to 800 130 (7.9) 60 (2.36) 21 (.83) 59 (3.60)
response to
60 (870) 180 (11) 60 (2.36) 21 (.83) 59 (3.60)
(CETOP 3) 12 (3.17) 10 (150) 80
to (1160) 250 to 800 250 (15.2) 75 (2.95) 18 (.71) 79 (4.82)
ER 9.0 - 10
80 (1160) 360 (22) 75 (2.95) 25 (.98) 110 (6.71)
500 (30.5) 75 (2.95) 22 (.87) 97 (5.92)
750 (45.7) 75 (2.95) 30 (1.18) 132 (8.06)
High 40 (11) 70 (1000) 80 (1160) ER9.4 -10 40 to 150 130 (7.9) 60 (2.36) 21 (.83) 59 (3.60)
response to to 180 (11) 60 (2.36) 21 (.83) 59 (3.60)
40 (11) 80 (1160)
(CETOP 5) 80 (21) 100 (1450) 250 (15.2) 75 (2.95) 18 (.71) 79 (4.82)
to 70 (1000) to ER 9.4 - 10 40 to 150
360 (22) 75 (2.95) 25 (.98) 110 (6.71)
80 (21) 100 (1450)
500 (30.5) 75 (2.95) 22 (.87) 97 (5.92)
750 (45.7) 75 (2.95) 30 (1.18) 132 (8.06)
200
XB XA TVW*-500...750
160
pSt1
120
80
TVW*-250...360
40
TVW*-130...180
A B L1/L2 0
p2 bar 0 100 200 300 400
p2 psi 0 1450 2900 4350 5800
Drive torque "compensated"
1
1 Pressure limiter setting The patented circuit provides
extremely short response
times for the pressure
3 2 Power limiter setting compensator regardless of
2
Motor Pump the servo control used:
3 SP Displacement control The response time is
flow from B independent from the
flow from A particular flow characteristic!
Pump Motor
10
7
p T
A B
9
7 XB XA
p T
A B
PB PA T A B T T p St 8.1 8.1
p St1 PB PA T A B T T p St
p St1.1
6.1 MSt
2.3 2.4
6 A St B St T MA p Sp2 p St2
2.1
L5
L3 2.1 4 5
L3.1
1 2 1.1 4
A, B System port MSp Gauge port charge S Suction port for 3.1 Low pressure relief
ASt, BSt Pilot oil port pump pressure charge and pilot valve
side A, B MSt Gauge port pilot pump 3.2 Flushing flow shuttle
L1, L2 Drain port pressure T Tank port valve
L3 Ventilation port for pac1 Accumulator port XA, XB Pilot port pressure 4 Charge pump
vertical mounting pSp1 External port charge control 5 Pilot pump
L3.1 Air bleeding port flow 1 Basic pump 6 Connection plate for
L4 Drain port pSp2 Additional charge 1.1 High pressure relief SP-Control
(charge oil) pump outlet port valve 6.1 Pilot pressure relief
L5 Oil filling plug pSt1 Port for pilot 2 Charge block valve
pressure 2.1 Charge check valve 7 Proportional valve
L6 Drain port
(flushing oil) pSt1.1 Port for pilot 2.2 Charge pressure 8.1 Pressure limiter 100 to
pressure relief valve 350 bar
L7 Port for return line
of control circuit pSt2 Piston pump outlet 3 Flushing block 9 Fail safe valve
port intermeditate plate
MA, MB Gauge port system
pressure 10 Pilot oil filter
+100%
0
-Voltage +Voltage
-100%
B A
p St
Dimensions in mm
Feedback
Proportional (potentiometer)
control valve with visual
401
404
315
463
203
L9 340 indicator
55
18
Fail safe valve Spring centering
0
243
121.2 intermediate plate
L6 High pressure relief valve MB
p Sp2 (double acting) ML
Setting range 100...350 bar Shuttle and low pressure
MB relief valve
MA Setting range
92 12...30bar
Charge pressure 20 MA
relief valve L3 p Sp2
55 9
169 10 L3.1 (L8)
163.5 A
140 A L1 42
47 "X" 20
66 85
53.5
72 42
B MSp 31.75 90
B
p Sp1 L2
S Center bore 82 4xM12-18deep S
176 44 Ø32
DM16 DIN332 68 80 156 66.7
240 110 M14-20deep
W50x1.25x10a DIN 5480
451.5 51 MSt M Sp
119 p Sp1
el. contamination
Adjustment pilot indicator for
L5 charge pressure
oil relief valve
L8 Port S
438 L4 SAE 1 1/4", 3000psi
ML
250
326 clockwise
L1 130 Ø50 k6 72 Ø 34 58.7
48.5 L2 -V
M10-15-deep
Ø200 Ø160 f7 +V
30.2
113 14 h9
L2
L1 Charge and pilot pump
200 L3 (40/8ccm)
200 18
113
210 L3.1 Flushing block
220 260 105 139
View "X" (596)
A System pressure L4 Drain port G 3/4” (MB) Gauge port system pSp2 Additional charge
port SAE 1 1/4”, (charge oil) pressure G 1/4” pump outlet port
6000 psi L5 Oil filling plug (ML) Gauge port of case G 3/4” (closed)
(L1) Drain port 1 1/16” - 1 1/16” - 12 UNF-2B pressure G 1/4” S Suction port of
12 UNF-2B L6 Drain port G 3/4” (M ) Sp Gauge port of charge and pilot
(according to (flushing oil) charge pressure pump SAE 1 1/4”,
mounting position G 1/4” 3000 psi
use upper port) (L8) Air bleeding port (common port)
G 1/4” (MSt) Gauge port of pilot
L2 Drain port G 1” pressure G 1/4”
(according to (L9) Drain port for low
pressure relief valve pSp1 External port of (...) Normally plugged
mounting position
use upper port) G 1/4” charge pressure
(MA) Gauge port system G 3/4”
(L3) Ventilation port for
vertical mounting pressure G 1/4”
G 3/8” (shaft
upwards)
34 EATON Vickers Hydrokraft Transmission Piston Pumps V-PUPI-TM002-E February 2003
Pump
Dimensions -
TVWS 250
Dimensions in mm
532.5
464 L9
412
457
471
230
355
64
393.5
0
361 Feedback (potentiometer) MB
with visual indicator
L6
L6 High pressure relief
valve (doubleacting Charge pressure
MB relief valve
Setting range 115 MA
10 100...350 bar 20 p Sp2
341 8 p Sp1 p ac1
240 L3.1 (L8) p St2
160 Charge pressure 10 L3 A
120 A relief valve 85
50 L1 100
X 69 B
B pac1 75 36.6 90
32
Center bore L2
pSp1 DM20 DIN332 105 M Sp
200 pSp1 38 S Charge and 112
238 135 80 196 79.4 pilot pump (64/8ccm)
M16-22deep
90 4xM1-18deep Port S
View X 242.5 SAE 2", 3000psi
29 W62x48x1.25x10a
DIN5480 51 77.8
Spring centering 80
L8 L5 MA
Stroke limitation ML M12-18deep
50...100% of Vmax MB 42.9
494 Port p Sp2
18 h9 81
403.5 41.7 SAE 1", 3000psi
ø200 f7 Screw plug M10-15deep
382.5 L2 L1 M27x2
ø65 m6 p St2 52.4
250 p Sp2
125 L1 L2 A/B
L3.1
Shuttle and low 26.2
233 L3 pressure relief valve
228 22 300 110 163.5 L9
L4
234 573.5
(688.5)
DIRECTION OF ROTATION RANGE OF SWASH ANGLE INPUT OUTPUT
A System pressure (L3) Ventilation port for (L9) Drain port for low (pSp1) External port of
port SAE 1 1/2”, vertical mounting pressure relief valve charge pressure
6000 psi G 3/8” (shaft G 1/4” G 3/4”
B System pressure upwards) (MA) Gauge port system (pSp2) Additional charge
port SAE 1 1/2”, (L3.1) Port G 1/8” pressure G 1/4” pump outlet port
6000 psi L4 Drain port G 1” (MB) Gauge port system M27x2
(L1) Drain port 1 5/8” - (charge oil) pressure G 1/4” pSt2 Pilot pump outlet
12 UNF-2B (L5) Oil filling plug (ML) Gauge port of case port G 3/8”
(according to 1 1/16” - 12 UNF-2B pressure G 1/4” S Suction port of
mounting position charge and pilot
use upper port) L6 Drain port G1” (MSp) Gauge port of
(flushing oil) charge pressure pump SAE 2”,
L2 Drain port G 1 1/4” G 1/4” 3000 psi
(according to (L8) Air bleeding port (common port)
mounting position G 1/4” (pac1) Accumulator port
use upper port) G 1”
(...) Normally plugged
EATON Vickers Hydrokraft Transmission Piston Pumps V-PUPI-TM002-E February 2003 35
Pump
Dimensions -
TVWS 360
Dimensions in mm
Proportional control valve Fail safe valve intermediate plate
L9
493 Adjustment pilot oil relief valve
548.5
MB
428
371
473
230
487
478
64
Feedback (potentiometer)
0
375 with visual indicator L6
393.5
High pressure relief valve
L6 (double acting)
MB Charge pressure
Setting range (115) relief valve MA
10 100..350bar 20 p Sp2
341 L3.1 (L8) 8 p Sp1 p ac1
240 p St2
160 Charge pressure 10 L3 A
120 A relief valve
50 L1 66 85
X 69 100
pac1 75 B
B 36.6 90
32
L2
pSp1 105 S MSp
Center bore 112
200 38 Charge and
pSp1 DM20 DIN332 4xM16-18deep
pilot pump (80/8ccm)
238 135
80 196 79.4
242.5 W62x48x1.25x10a M16-22deep
p St1 DIN5480 90
29 Port S
View X SAE 2", 3000psi
Spring centering 51 77.8
80
L8 L5 MA
Stroke limitation M12-18deep
50...100% of Vmax ML MB 42.9
494 Port p Sp2
18 h9 81
403.5 41.7 SAE 1", 3000psi
Ø200 f7 Screw plug
382.5 L2 L1 M27x2
Ø65 m6 52.4
p St2
250 p Sp2
125 L1 L2 A/B
L3.1 26.2
233 L3 Shuttle and low
22 316 110 163.5 pressure relief valve
L4 228 589.5 L9
234 (704.5)
A System pressure (L3) Ventilation port for (MA) Gauge port system (pSp2) Additional charge
port SAE 1 1/2”, vertical mounting G pressure G 1/4” pump outlet port
6000 psi 3/8” (shaft upwards) (MB) Gauge port system M27x2
B System pressure (L3.1) Port G 1/8” pressure G 1/4” pSt2 Pilot pump outlet
port SAE 1 1/2”, L4 Drain port G 1” (ML) Gauge port of case port G 3/8”
6000 psi (charge oil) pressure G 1/4” S Suction port of
(L1) Drain port 1 5/8” - (L5) Oil filling plug 1 1/16” (MSp) Gauge port of charge and pilot
12 UNF-2B - 12 UNF-2B charge pressure pump SAE 2”,
(according to G 1/4” 3000 psi (common
mounting position L6 Drain port G 1” port)
use upper port) (flushing oil) (pac1) Accumulator port
(L8) Air bleeding port G 1”
L2 Drain port G 1/4” (...) Normally plugged
(according to G 1/4” (pSp1) External port of
mounting position (L9) Drain port for low charge pressure
use upper port) pressure relief G 3/4”
valve G 1/4”
Dimensions in mm
466.5
607.5
680.5
Spring centering
191.5
Adjustment pilot oil relief valve
605
300
L6 523 Stroke limitation
0
420 p St1 Feedback (potentiometer) 50...100% of Vmax
with visual indicator MB Port p Sp1
Charge pressure 115 MA SAE 1", 3000psi
relief valve 10 M10-16deep
L8 25 L6
L4 52 pSp2 52.4
400 pSp1 L3
566 270186 Center bore 40 pSt2 Ø25
L1 45 L2 MSp DM20 DIN332 A 40
L1 26.2
145 18 125
X 18 85 Port p Sp2
74 120
B SAE 1 1/4", 3000psi
201 115 L2 90
G1" M12-18deep
L2 L1 44.5
High pressure S 58.7
relief valve 105
4xM16-29deep 50 Charge and pilot pump
S 180 64.5 (double acting) (125/8 ccm/U)
Setting range 100..350bar 95 255 30.2
426 96.8 M20-25deep
105
95
W80x3x25x MSp SAE 2", 3000psi
View X 10a DIN5480 L4
L5 Ø51 77.8
View Y - Port L4, MSp , p Sp1 ML p Sp1
only charge block with filter L8 L2/L1
42.9
L4 402 Charge pressure relief valve
L2 L1 186 L4
clockwise Ø250 f7
p ac1
Y MSp p St2
247 Ø70m6 20 h9
315 166 p Sp2
38 201
L1 L2 50 166 L3 40 Shuttle and low
L1/L2 40 pressure relief valve
300 100 MA
310 391.5 150 180
MB
116 320 (836.5)
A System pressure (L3) Ventilation port for (MA) Gauge port system (pSp2) Additional charge
port SAE 2”, vertical mounting G pressure G 1/4” pump outlet port
6000 psi 3/8” (shaft upwards) (MB) Gauge port system M27x2
B System pressure (L3.1) Port G 1/8” pressure G 1/4” pSt1 Port of pilot
port SAE 2”, L4 Drain port G 1” (ML) Gauge port of case pressure G 1/2”
6000 psi (charge oil) pressure G 1/4” pSt2 Pilot pump outlet
(L1) Drain port 1 5/8” - (L5) Oil filing plug 1 (MSp) Gauge port of port G 3/8”
12 UNF-2B 1/16” - 12 UNF-2B charge pressure
(according to G 1/4” S Suction port of
mounting position L6 Drain port G 1”
(flushing oil) (M ) Gauge port of pilot charge and pilot
use upper port) St
pump SAE 2”,
(L8) Air bleeding port pressure G 1/4”
L2 Drain port G 1/2” 3000 psi
(according to G 1/4” (pac1) Accumulator port (common port)
mounting position (L9) Drain port for low G 1”
use upper port) pressure relief (pSp1) External port of
valve G 1/4” charge pressure (...) Normally plugged
G 3/4”
EATON Vickers Hydrokraft Transmission Piston Pumps V-PUPI-TM002-E February 2003 37
Pump
Dimensions -
TVWS 750
Dimensions in mm
532.5
Adjustment pilot oil relief valve
495.5
Spring centering
198.5
660.5
55.5
462.5
496
307
756
462 Stroke limitation
0
Feedback (potentiometer)
with visual indicator 50...100% of Vmax
pSt1 Flushing block
p 115 L6 MSp
L6 St Charge pressure
pSp2(closed) L4
relief valve p ac1
45 pSp1 (closed) 32 pSt2
ML
273 MSp 40 380
L1 L8 40 A 118
145 pac1 L3 L1 75
(85) 18 125 66 85 39
120
X 0
(90) 239 B 90
18 115 44.5
Center bore
L2 DM24 DIN332
L1
105 S Charge and pilot pump
4xM16-29deep
S 180 62 (200/8 ccm/U)
101.5 255
425 Ø50 96.8 M20-25deep
Proportional control valve pac1 MSp pSp1(closed)
pSt1.1 pSt1 MSt Port p Sp2 (closed)
View X L7 Fail safe valve Shuttle and low
565 intermediate plate L2/L1 pressure relief valve 35.7
L5 Setting range 12...30bar
ML 69.8
184.5 L6
pSp2 (closed)
MSp MAB
W90x3x28x9g 95 p St2 Port S
567 p ac1 L2 cw L1 -V SAE 3", 3000psi
188.5 41
422.5 478 DIN5480
+V 72 80 Ø73 106.3
Ø250 f7
166
Ø315 L2 L3/L8 A/B 62
L1 9
L1/L2
180 106.5 High pressure relief valve
26 420.5 150 226
300 Setting range 100..350bar
110.5 316 (796.5)
A System pressure L6 Drain port G 1 1/4” (pac1) Accumulator port pSt2 Pilot pump outlet
port SAE 2”, (flushing oil) G 1 1/4” port G 3/8”***
6000 psi L7 Port G 3/8” for (pac2) Accumulator port S Suction port of
B System pressure return line of control G1 1/4” (optional) charge and pilot
port SAE 2”, circuit (pSp1) External port of pump SAE 3”, 3000
6000 psi (L8) Air bleeding port charge pressure psi (common port)
(L1) Drain port 1 5/8” - G 1/4” G 1” (Port of charge
12 UNF-2B* (MAB) Gauge port system pressure internal) (...) Normally plugged
L2 Drain port G 1 1/2”* pressure G 1/4” (pSp2) Additional charge *) According to
(L3) Ventilation port for (ML) Gauge port of case pump outlet port mounting position
vertical mounting pressure G 1/4” G 1/4” use upper port
G 3/8”** (MSp) Gauge port of pSt1 Port of pilot **) Shaft upwards
L4 Drain port G 1 1/4” charge pressure pressure
G 1/2” *** ***) Piping by
(charge oil) G 1/4” HYDROKRAFT
(L5) Oil filling plug (MSt) Gauge port of pilot (pSt1.1) Port of pilot (alternatively pSt1 or
1 1/16” - 12 UNF-2B pressure G 1/4” pressure G 3/8”*** pSt1.1)
Dimensions in mm
L1
Ø138
L2
View X
3 optional B1 alternative
orientations (3x90°) location
477
22 p Sp2
102 H1
H2 A H3
clockwise
View Y
B
S
42
51 L3
112.5
153.5
View X
View Y
p Sp2
El. motor
displacement control
L1 L2 L3 B1 H1 H2 H3 DISPLACEMENT (CCM)
130* 365 203 216,5 256 192 120 130 Pump Size Charge Pump
180* 365 203 216,5 256 192 120 130 130 40
250 410 230 222 271 236 135 160 180 40
360 426 230 222 285 236 135 160 250 63
500 541,5 300 222 330 267,5 172 186 360 87
750 571 307 222 372 270 172 188,5 500 125
* Only alternative location possible. 750 200
Dimensions in mm
36 S
39
98
SP - With pressure limiter 139 SP - With pressure limiter
overriding function overriding function
94
127.8
128
94
122
38
138
pressure
limitation
setting
44.75
power
limitation 52
setting 108.3
124
120
Dimensions in mm
306
173 242.5
48
40 40.5
View Y
p Sp2
p St2
M St
p St1
Dimensions in mm
L1 B1
L2 242.5
79 29
13
50 45
40.5
42
p Sp2
150
p St2
H1
A
H2 H3
View Y
96.5
132 B
S
47
61
122.5
SP - With pressure limiter SP - With pressure limiter
overriding function overriding function
122 94
142
47.6
140
47.75
pressure limitation
122 setting 88.3
103
power limitation L1 L2 B1 H1 H2 H3
setting
250 410 230 271 236 135 160
360 426 230 285 236 135 160
500 541,5 300 330 267,5 172 186
750 571 307 372 270 172 188,5
Dimensions in mm
306
242.5
173
fail safe valve
48
40.5
40
spacer to be used
with filter and pressure
control only!
View Y
View Z
p St 1
p Sp2
M St
p St 2
p St1.1
Dimensions in mm
365
203
130 View X
96
A St 40 B St
20 12
View X
123
40 24
p Sp2
p St2
120 A
View Y
B
36 S
39
98
DP - With pressure limiter 139
overriding function
127.8
138
DP - With pressure limiter
and power control overriding
function
pressure
limitation
setting
power
124 limitation
setting
Dimensions in mm
42
94
View Y
128
94 p Sp2
122 p St2
38
44.75
52
108.3
120
Dimensions in mm
p Sp2
22
p St2
A
H2
View Y
13 2 B
S
47
DP - With pressure 61
limiter overriding function 122.5
122
140
DP - With pressure
limiter and power
control overriding function
pressure
limitation
setting
L1 L2 B1 H1 H2 H3
Dimensions in mm
45
H1
H3
96 .5
View Y
p Sp2
DP - With pressure p St2
limiter overriding function
94
14 2
47 .6
S
DP - With pressure
limiter and power
control overriding function
47 .7 5
88 .3
DISPLACEMENT FOR CHARGE PILOT PUMPS (CCM)
10 3
Pump Size Charge Pump Pilot Pump
250 64 8
360 80 8
500 125 8
750 200 8
Dimensions in mm
View X
365
20 3
50
12 9
73 .5
65
40
p Sp2
p St 2
12 0 A
View Y
36 S
39
98
SM - With pressure limiter
overriding function 13 9
12 7. 8
pressure limitation
setting
power limitation
setting
12 4
Dimensions in mm
256
18 0
52. 1
90 View X
p St 1
42 cable connector
pilot pressure
PS
t adjustment
swash angle indicator
11 4
19 2
clockwise 13 0 PS
t
93 .5
p St 1 : G 1 /2 "
M St : G1 /4 "
94
View Y
p Sp 2
94 12 8 p St 2
122
38
44 .7 5
52
108 .3
120
Dimensions in mm
View X
L1
L2
139 50
73. 5
65
40
p Sp2
22
p St2
A
H2
View Y
132 B
S
47
SM - With pressure limiter 61
overriding function 122. 5
122
140
SM - With presure limiter and
power control overriding
function
L1 L2 B1 H1 H2 H3
Dimensions in mm
B1
180
90 52. 1
45 p St1
View X
PS
t pilot pressure
swash angle indic ator adjustment cable connector
150
H1
H3
96. 5
p St1: G1/2"
M St : G1/4"
View Y
p Sp2
p St2
SM - With pressure limiter
overriding function
94
142
47. 6 S
Dimensions in mm
HS
LS
Dimensions in mm
cw
pressure
optically indicated control setting (for side A)
swash angle Port A
+V -V
pressure
control setting for side B outlet inlet
Port B
Port A (upper)
Port B (lower)
rotation direction: cw, ccw requires aspezial setup for charge and pilot pump
ACTUATOR PISTON
STOP A STOP B
(+V) (-V)
Inlet port B A
Outlet port A B
Installation position
Installation position is
optional however note
bearing lubrication with
respect to mounting
INSTALLATION POSITION DRAIN PIPING INSTALLATION POSITION DRAIN PIPING
Shaft horizontal Shaft pointed downwards
Pump can be rotated freely Use ventilation line L4 L4
about the lateral axis Prime main case drain connection
L1 L2 (L1) with 0,2 bar (2.9 psi)
Use the highest case drain
connection L1 or L2 L1 L2
L2
L3
LB
L3
PV500...750
PV130...360