You are on page 1of 11

ENGINEERING DATA

D03 FluiDyne Valves


• 4 Way, 2 and 3 Postion Solenoid Operated
• Variety of Voltage and Spool Configurations
• Same Day Shipments
• 18 Month Warranty

www.FluiDyneFP.com
D03 FluiDyne Valves:
4 Way, 2 and 3 position solenoid operated directional D03 valves with a variety of voltage and spool configurations.

Flow Rate 14 gpm 18 month warranty

310 bar / 4500 psi Cost effective replacement to Rexroth, Bosch, Vickers and
Parker with superior performance
100 bar / 1450 psi tank port pressure
Large inventory allows same day shipment
Endurance tested to 10 million cycles

Features & Benefits:


WFDG4V-3S (D03)
Standard Performance Models:

Up to 60 l/min. (15 US gpm) Electrical Connections


P Conduit box and DIN connection
respectively at 310 bar (4500 psi)
A designs simplify electrical wiring
B connections to solenoids.
International standard
T interface.
The valve mounting face conforms Orientation tabs prevent
Mounting
to ISO 4401, surface
size 03 andtois incorrect positioning.
ISO 4401 size 3
compatible with related
international standards.

P
P
A
A B
B
T
T
Mounting surface to
Mounting
ISO surface
4401 size 3 to
ISO 4401 size 3
Ease of Servicing
Wet-armature solenoid,
screw in core tube design
allows coils to be changed
without removing valve from
installation and without oil
ISO4400
spillage (DIN of
or risk 43650)
contamination
coil shown
system fluid.

ISO4400 (DIN 43650)


ISO4400
coil shown(DIN 43650)
coil shown

Your Trusted Choice for Valves! 1


Model Code Breakdown
WF DG4V—3(S)—** *(L)—(**)—(V)M—(S*)—* ** * D* (L)—* *—6*—(EN***)—(P**—A**—B**—T**)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

1 Model Series 5 Solenoid energization 8 Coil type 10 Housing (F type coils only)
D – Directional valve identity U – ISO 4400 (DIN 43650) W – 1/2" NPT thread
G – Subplate/manifold mounted V – Solenoid “A” is at port “A” mounting wiring housing
4 – Solenoid operated end and/ or solenoid “B” is U1 – Connector fitted
at port “B” end, indepen-
V – Pressure rating 350 bar dent of spool type U6 – Connector fitted w/lights
(5075 psi) on P, A & B ports U11 – Connector fitted
Omit for U.S. ANSI B93.9 11 Surge suppressor/
standard requiring solenoid w/rectifier & lights
2 Standard or high damper
“A’’ energization to connect U12 – Connector fitted
performance P to A and/or solenoid “B’’ to w/rectifier D1 – Encapsulated diode
3* – - connect P to B, independent (Industrial applications)
F – 1/2" NPT thread
cation: up to 80 l/min (21 of solenoid location. D2 – Encapsulated diode
conduit box
USgpm) at 350 bar (5075 psi) NOTE: Type “8” spool valves (Mobile applications)
3S – Standard performance conform to both U.S. and D7 – Transzorb type
specification: up to 40 European solenoid designa - (U only)
l/min (10.5 USgpm) at tions. When ordering an “8”
350 bar (5075 psi) spool, designate a “V” in the 12 Solenoid indicator lights
model code.
3
L available on U, U1, U6, W
Spool type
6 Flag symbol 9 Electrical connector
See page 4.
M – Electrical options and T – Wired terminal block 13 Coil rating
4 features
Spool Spring PA – Instaplug male Full power coils, see
Arrangement receptacle only “Operating Data”.
7 Spool indicator switch*
A – Spring offset, end-to-end PB *– Instaplug male & A – 110V AC 50Hz
AL – Same as “A” but left Available on high performance female receptacle
hand build models, DG4V-3, only. Omit B ◊ – 110V AC 50Hz/120V AC 60 Hz
when not required. PA3* – Three pin connector
B – Spring offset, end1 to center 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16C“ – 220V17AC 50 Hz 18
BL – Same as “B” but left PA5 – Five pin connector
D ◊ – 220VAC 50 Hz/240VAC 60 Hz
hand build
G – 12V DC
C – Spring centered14 Port T code g 16 Special features
N*– No-spring detented H – 24V DC
Refer to “Operating Data” for “EN***”* code number ◊For 60 Hz or dual frequency
port T pressure ratings. assigned as required.
5 – 100 bar (1500 psi) for stan- EN21* – CSA approved models 14 Port T code
dard performance models, with 1/2” NPT entry
conduit box, type FW Refer to “Operating Data” for
DG4V-3S, with AC or DC
and solenoid coil letter port T pressure ratings.
solenoids.
B,D,G, or H. 5 – 100 bar (1500 psi) for stan-
6*– 207 bar (3000 psi) for AC
high performance models, dard performance models,
DG4V-3, including spool 17 Port restrictor plugs DG4V-3S, with AC or DC
solenoids.
Contact our customer
position indicator type S6. For details of plug orifice sizes
and how to specify in model 6 – 207 bar (3000 psi) for AC
service department
7* –207 bar (3000 psi) for DC
high performance models,
high performance models, code. Maybe fitted to valves
for additional coil and
DG4V-3, including spool by agreement with your DG4V-3, including spool
spool options!
position indicator type S6. FluiDyne representative. position indicator type S6.
Omit – No restrictor plugs 7 – 207 bar (3000 psi) for DC
fitted high performance models,
15 Design number
* Reman only! DG4V-3, including spool
60 – Basic design position indicator type S6.
61 – Type 8 spool
15 Design number
60 – Basic design
61 – Type 8 spool

EATON Vickers Solenoid Operated Directional Valves


www.FluiDyneFP.com Product Catalog V-VLDI-MC011-E September 2008 2 5
Characteristics
WFDG4V-3S models are direct
solenoid operated
directional control valves.
Their primary function in a
hydraulic circuit is to direct Construction of a typical
fluid flow. This, in turn, would single solenoid model.
determine the direction of
movement of a fluid cylinder,
or the direction of rotation of
a fluid motor.

Port connections are made


by mounting the valve on
a subplate or manifold. The
valve has wet armature type
solenoids.

Electrical connections to
the valve are made in the
electrical wiring housing or
through various plug-in connectors
such as a DIN 43650 type coil.

Good hydraulic design practice


suggests that detented models
be mounted with longitudinal
axis horizontal. Other models may
be mounted in any position.

Our people provide extensive support:

Engineering
l Expertise

Decoding
l special part numbers

Identification
l of parts within units

Advice
l on component repair and assembly

Component
l failure analysis

Large
l local stock

New
l application component selection

Same
l day shipment

18
l month warranty

Call us today to find out what makes us so great! (586) 296-7200


3
sent
sentthe
thehighest
highestproportion
proportion BB . P.lPl ooTTSS AA
ofofmarket
marketrequirements.
requirements.ForFor s s Transient
Transientcondition
conditiononlyonly
other
otherspool
spoolfunctions
functionsthat
thatmay
may
be
berequired,
required,consult your
Eaton
Eatonsales
Functional
consult your
salesrepresentative.
representative.
U.S. solenoid standard
The
Thevalve
valvefunction
functionschematics
schematicsapply
applytotoboth
bothU.S.
U.S.and
andEuropean
Europeanvalves.
Functional
Symbols Symbols
Double solenoid valves, Single
U.S.
valves.
solenoid
Solenoid valves,
Standard Single solenoid valves,
Solenoids
Solenoidsidentified
identifiedtotoU.S. U.S. two
DG4V-3(S)-*N(V) position, detented solenoid
DG4V-3(S)-*A(V)
DG4V-3(S)-*A(V) at port A end solenoid
DG4V-3(S)-*AL(V) at port Bvalves,
end
Double
DG4V-3(S)-*N(V) solenoid valves, Single solenoid valves, Single solenoid
DG4V-3(S)-*AL(V)
standards
standards identified to U.S. standards two position, detented
Solenoids A B B at port B end
solenoid at portA A end
B solenoid
A
Functional 22 00 00
Functionalsymbols
symbolsrelated
relatedtoto A B A B A B
solenoid
solenoididentity
Functional identity
symbols“A”
“A”and/or
and/or
related to solenoid
“B”
“B”according
according totoNFPA/ANSI
NFPA/ANSI B . l oP S T 22 A oSol.S B P T 22 P T Sol. A
identity “A” and/or “B” according to
standards, i.e. energizing
standards, i.e. energizing Double solenoid valves,
B . l o P S T A o Sol.S B P T P T Sol. A
NFPA/ANSI
solenoid standards, ex. energizing 2222 22
22
solenoid“A”“A”gives
givesflow
flowPPtoto spring centered
Double solenoid valves,
solenoid
A,
A,solenoid
solenoid“A”
“B” gives
“B” gives flow
flowPP
givesflow P to A, solenoid spring centered
A B
“B”
toBBgives
to (as flow P to B (as applicable).
(asapplicable).
applicable). 2424 24
24
Spool types shown repre- A B
sent thePorthighest
Port PP proportion B . Pl o T S A
Port
PortAA of market DG4V-3(S)-*C(V)
requirements. For
DG4V-3(S)-*C(V)
s Transient SDG4V-3(S)-*B/F(V)
.Pl o T only
B condition DG4V-3(S)-*B/F(V)
A DG4V-3(S)-*BL/FL(V)
DG4V-3(S)-*BL/FL(V)
other spool functions that may
s Transient condition only
Solenoid
Solenoid be required, consult your00
Solenoid
Solenoid 00 00
Eaton sales representative. The valve function schematics apply to both U.S. and European valves.
Port
PortBB 22 The valve function
22 schematics apply to both U.S.
22 and European Valves
Port
PortTT
Solenoids identified to U.S. DG4V-3(S)-*N(V) DG4V-3(S)-*A(V) DG4V-3(S)-*AL(V)
FOR
FOR 66 DG4V-3(S)-*N(V) 66 DG4V-3(S)-*A(V) 66 DG4V-3(S)-*AL(V)
Sstandards
SPOOL
POOL
66
66 2 66
66 0 66
66 0
SOLENOID
SOLENOID TYP
TYPE E SOLENOID
FunctionalSOLENOID symbols related to 2 0 0
BB All
All
solenoid Aidentity
A 77
“A” and/or 77 77
except 2 2
“B”
except according to NFPA/ANSI 2 2
standards,
“8”
“8” i.e. energizing
22 22
22 22 22 22
22 22 22 22
22 22
22 22
22 22
AA “solenoid
“ ”8o”onnlyly B“A”
8 B gives flow P to
A, solenoid “B” gives flow 33
33P 33
33 33
33
For
Forvalves
valveswith 24 24
totype
with type
B (as “8”spools,
applicable). 34
“8”spools, 34 34
34 24 34
34 24
solenoid
solenoid
For identity
withtoto
identity
valves U.S.
U.S. “8” spools,
type 5 5 5522 22 55 22 55
convention
conventionisisthe
thesame
solenoidconvention. sameasasfor
identityPort
to U.S.
A
for Port P 5 5 DG4V-3(S)-*C(V) DG4V-3(S)-*B/F(V)
5522
DG4V-3(S)-*BL/FL(V)
European
European convention. DG4V-3(S)-*C(V) DG4V-3(S)-*B/F(V) DG4V-3(S)-*BL/FL(V)
convention is the same as for 55 55 5566 66 55 5566 66 55
0 0 0
European convention.
Solenoid Solenoid 0 0 0
Solenoids
Solenoidsidentified
identifiedtoto
European
Europeanstandards
standards 2 2
Solenoids
(specify identified to European DG4V-3(S)-8C(V)
Port B
DG4V-3(S)-8C(V) 2 DG4V-3(S)-8BL(V)
DG4V-3(S)-8BL(V)
2 DG4V-3(S)-8B(V)22
DG4V-3(S)-8B(V)
(specify“V”
“V”inin model
model code)
code)
Port T
standards (specify “V” FORin model 88 code) 66 88 6 88 6
Functional
Functionalsymbols
symbolsrelated
related 666 666
S POOL 66 66
totosolenoid
solenoididentity
SOLENOID“A”
identity “A”and/
and/
TYP E SOLENOID 66 66
Functional
oror“B” symbols
“B”according
according related
to European to solenoid
identity B to European
“A”i.e.
and/or “B”“A”All
according A
European
European
to
7
solenoid
solenoid
7 standard
standard
7
7 7
7
convention
convention i.e.solenoid
solenoid “A”
European
adjacent convention except
ex. solenoid “A”solenoid
adjacenttoto“A”
“A”port,
port,solenoid
solenoid Double
Double solenoid valves,
valves,
22 2222 Single
Singlesolenoid
solenoid valves,
22valves,
22 Single
Singlesolenoid
solenoidvalves,
valves,22
22
“B”
“B”adjacent “8” two
twoposition, 22
position,detented solenoid 22AAend
solenoidatatport 22 solenoid
solenoidatatport22 end22
BBend
adjacent to to
adjacent to“B”
“A” “B”port
port, ofof
portsolenoid “B” detented port end port
valve.
valve.
adjacnet to A “ 8”only B
“B” port of valve. 33
A33
A BB A33 B
33
A B AA BB 33
33
For valves with 34 34 34
Port A Port
Port PP type “8”spools, 34 34 34
Port A solenoid identity to U.S.
5 5 52 2 5 5 2 B 22 55
convention is the same as Sol.forAA
Sol. PP5 5TT Sol.Sol.BB Sol.
Sol.AA 5PP2 2TT 5 PP TT 5Sol.
2 B
Sol.
Solenoid
Solenoid European Solenoid
convention.
Solenoid
AA BB 5 5 56 6 5 56 6 5
5 5 56 6 5 56 6 5
Double
Doublesolenoid
solenoidvalves,
valves,
Port
PortBB
PortTTSolenoids identified tospring
Port springcentered
centered
•For
• For European
differences in standards DG4V-3(S)-8C(V)
AA DG4V-3(S)-8C(V)
BB DG4V-3(S)-8BL(V) DG4V-3(S)-8B(V)
For differences
difference ininvalve
(specify
valve
valve
“V”
func
func
in
--
function,
model code)
DG4V-3(S)-8BL(V) DG4V-3(S)-8B(V)
tion, refer to Performance
tion, refer to Performance
refer
Data topage
Datapage
performance
11.
11.
data. 8
8
8
8
8
8
Functional symbols related Sol.AA PP TT
Sol. Sol.
Sol.BB
F Build Spools*
◊◊ FFbuild to solenoid identity “A” and/
buildspools.
spools. s s Transient
Transientcondition
conditiononly
only
or “B” according to European European Solenoid Standard (V)
convention i.e. solenoid “A” European solenoid standard
44 EATON
EATONVickers
Vickers Solenoid
SolenoidOperated
OperatedDirectional
DirectionalValves
Valves Product
ProductCatalog
CatalogV-VLDI-MC011-E
V-VLDI-MC011-ESeptember
September2008
2008
adjacent to “A” port, solenoid Double solenoid valves, Single solenoid valves, Single solenoid valves,
“B” adjacent to “B” port of two position, detented solenoid at port A end solenoid at port B end
valve. A B A B A B
Port A Port P
Sol. A P T Sol. B Sol. A P T P T Sol. B
Solenoid Solenoid
A B
Double solenoid valves,
Port B spring centered
Port T
• For differences in valve func - A B
tion, refer to Performance
Data page 11. P T 4
Sol. A Sol. B
◊ F build spools.
s Transient condition only

4 EATON Vickers Solenoid Operated Directional Valves Product Catalog V-VLDI-MC011-E September 2008
Operating Data

D03 FluiDyne Valves


Performance data is typical with fluid at 36cSt (168 SUS) and 50°C (122°F).
Performance data is typical with fluid at 36cSt (168 SUS) and 50°C (122°F).
STANDARD PERFORMANCE VALVE
FEATURE WFDG4V3S
STANDARD PERFORMANCE VALVE
FEATURE
Pressure Limits WFDG4V3S
Pressure
P, A and Limits
B ports 310 bar (4500 psi)
TP, port:
A and B ports 100 bar (4500
310 (1450 psi)
T port: 100 bar (1450 psi)
Flow rating See performance data
Flow rating
Relative duty factor See performance
Continuous; ED = data
100%
Relative duty
Type of protection:factor Continuous; ED = 100%
Type of 4400
ISO protection:
coils with plug fitted correctly IEC 144 class IP65
ISO 4400
Coil winding coils with plug fitted correctly IEC 144
Class H class IP65
Lead wires (coils type F***)
Coil winding Class H
Coil
Leadencapsulation
wires (coils type F***) Class FH
Coil encapsulation
Permissable voltage fluctuation: Class F
Permissable
Maximum voltage fluctuation: Refer to temperature limits.
Minimum
Maximum 90%
Referrated
to temperature limits.
Minimum
Typical response times at 100% rated volts measured from 90% rated
application/removal
Typical response times of at
voltage
100% to full volts
rated spoolmeasured
displacement
fromof “2C” spool at:
application/removal
Flow rate P-A, B-Tof voltage to full spool displacement of “2C” spool at:20 l/min (5.3 USgpm)
Pressure
Flow rate P-A, B-T 175 bar (2537
20 l/min psi)
(5.3 USgpm)
AC (~) energizing
Pressure 18
175msbar (2537 psi)
AC (~) de–energizing
energizing 32
18 ms
DC (=) de–energizing
AC (~) energizing 60
32 ms
DC (=) de–energizing
energizing 40
60 ms
DC consumption,
Power (=) de–energizing AC solenoids 40 mss
Initial Holding
Power
(forconsumption, AC solenoids
coils listed in model code). Initial
VA (RMS)s Holding
VA (RMS)
Full(for coilscoils:
power listed in model code). VA (RMS) VA (RMS)
FullSingle
powerfrequency
coils: coils AC 50 Hz 225 39
Dual
Singlefrequency
frequencycoils
coilsatAC
5050
HzHz 265
225 49
39
Dual frequency coils at 60 50 HZ
Hz 260
265 48
49
Dual frequency coils at 60 HZ
Power consumption, DC solenoids at rated voltage and 20 C (68 F). 260 48
Power
Full consumption,
power coils: DC solenoids at rated voltage and 20 C (68 F).
Full12V,
power coils:
model type “G” 30W –
24V,
12V, model type “H”
“G” 30W –
24V, model type “H” 30W –

Call, Email or LiveChat us Today!


5
Performance Data

Performance
DG4V3S models
Data
WF DG4V3S Models
Graph 1 – Single-frequency coils Graph 2
AC solenoid valves with: – Dual-frequency coils AC solenoid valves with dual-
operating at 50 Hz frequency coils operating at 60 Hz

psi bar psi bar


4500 4500
300 300
4000 3 2 1 1
5 4 4000 2
250 3
250
5
Pressure

Pressure
6 48
3000 200 3000 200
7 3
150 150
2000 8 2000 4 8
5 7 6
100 100
5
1000 1000
50 50

0 0
0 10 20 30 40 50 60 l/min 0 10 20 30 40 50 60 l/min
0 3 6 9 12 15 USgpm 0 3 6 9 12 15 USgpm
Flow rate

Graph 3
DC solenoid valves
psi bar
Spool/ Graph Graph Graph
4500 6 31 spring 1 2 3
300 code curve curve curve
4000 7 4 2
0A(L) 2 2 3
250
5 0B(L) & 0C, 0F 1 1 2
Pressure

3000 200 2A(L) 2 2 3


4 2B(L) & 2C, 2F 1 1 1
8 6
150 2N 1 1 2
2000
5 6B(L) & 6C, 6F 6 5 6
100 7B(L) & 7C, 7F 1 1 2
1000 8B(L) & 8C 5 4 5
50
22A(L) 8 7 8
22B(L) & 22C 7 6 7
0
0 10 20 30 40 50 60

0 3 6 9 12 15 USgpm
Flow rate

www.FluiDyneFP.com 6
Installation
Installation Dimensions
Dimensions

Models for use with ISO 4400 (DIN 43650) connectors

Double solenoid models Single solenoid models


WFDG4V-3(S)-*C-**-(V)M-U-**-60 WFDG4V-3(S)-*A(-**) WFDG4V-3(S)-*AL(-**)
As Spolenoid
WFDG4V-3(S)-*B(-**) shown WFDG4V-3(S)-*BL(-**) and end cap
WFDG4V-3(S)-8BL(-**) WFDG4V-3(S)-8B(-**) interchanged

WFDG3V-3(S)-*F WFDG4V-3(S)-*FL(-**)
74.00 Alternate plug position by
D (2.91) loosening knurled nut, turning
coil, and re-tightening.
Coil types: U (shown)
100.0
(4.0)
87.0
(3.42)
53.00
(2.1)

25.00 C coil 38.00 24.00


(0.98) length (1.5) (0.94)
B (single solenoid model ) 48.00
A (double solenoid model) (1.88)

Port P
Port A
Port B
Port T

AC or DC A Dim. B Dim. C Dim. D Dim.


Dimensions in Inches. DC 8.66 6.14 2.5 2.87
AC 7.87 5.75 1.7 2.48

Sales@FluiDyneFP.com
7
Installation Dimensions

Models with “F” type coils (lead wires) and conduit box.

Double solenoid models Single solenoid models


WFDG4V-3(S)-*C-**-(V)M- F -**- 60 WFDG4V-3(S)-*A(-**) WFDG4V-3(S)-*AL(-**)
As Solenoid
WFDG4V-3(S)-*B(-**) shown WFDG4V-3(S)-*BL(-**) and end cap
interchanged
WFDG4V-3(S)-8BL(-**) WFDG4V-3(S)-8B(-**)
WFDG3V-3(S)-*F WFDG4V-3(S)-*FL(-**)

A (double solenoid model)

B (single solenoid models ) Thread connection


*W conduit boxes “W”– 1/2 NPT 50.00
(2.0)
Ground
connection
4.0 (0.16 dia.)
self–tapping Two lead
91.00 wires per
screw (3.57) solenoidwith
68.75 M3 size
(2.71) terminals for
53.00 customer
25.00 (2.1) connections
(0.98)
24.00
C coil 38 (0.94)
(1.5) 47
length (1.85) 48.00
74.00 (1.88)
D (2.91)

Port P
Port A
Port B
Port T

AC or DC A Dim. B Dim. C Dim. D Dim.


DC 8.66 6.14 2.5 2.87
Dimensions in Inches. AC 7.87 5.75 1.7 2.48

l Not applicable to type “8” spool.

Code “FW”: 2 lead wires for each solenoid, approximately 150.00 (6.0) long. M3 (#6)
terminals provided for customer connection.
Code “FTW”: Valve supplied with lead wires connected into terminal strip suitable
for M3 (#6) terminals for customer connection.

www.FluiDyneFP.com
8
Electrical Plugs & Connectors
Electrical
Terminal Strip and Lights for Valves with Type Plugs
“F” Coils
Electrical
andPlugs
Connectors
Terminal strip and lights
Terminal stripTerminal strip
and lights and Connectors
Conduit box cover and
For valves with type “F” coils. nameplate complete with
For valves with type “F” coils. sealing gasket and 4 screws
Terminal strip Conduit box cover and
Terminal strip (part numb er Conduit box nameplate
cover and complete with
(part numb 890345)
er clips ot Light assembly is held in place
890345) clipscoverot and can 4 terminal Electrical Plugs
screws nameplate
M3 x 0.5-6Hsealing gasket
complete
sealing gasket and 4 screws
with and 4 screws by end pair of M3 screws; can
be fitted to terminal strip.
cover and canbe d tted
Terminal
be stripdM3ttex 0.5-6H
and d lightsscrews
and Connectors
Connections to solenoid A
Light assembly is held in place
2 each end (or B, according
4 terminal screws M3 x 0,5-6H to model type )
For valves with type “F” coils. Light by end
assembly pairinofplace
is held M3 screws; can
M3 x 0,5-6H screws4 terminal screws (part number02-
M3 x 0,5-6H 113355 )
by end pair be fitted
of M3 to terminal
screws; can strip.
M3 x 0,5-6H (part number 186006)
screws (part number02- 113355 ) Connections to solenoid A be fitted to terminal strip.
(partTerminal
numberstrip 186006)2 each end Connections (ortoB,solenoid
Conduit accordingA to
box cover model type )
and
(part numb 28.50
erend (or B, according 30.00to model type )
2 each
(1.12) nameplate
(1.18) complete with
890345) clips ot sealing gasket and 4 screws
cover and can
be d tted 28,50 30,00
28,50 (1.12) 30,00 Anti-rotation
(1.18) tab ensures Light assembly is held in place
Connections to 4 terminal screws M3 x 0,5-6H correct orientation of cove r
(1.12)solenoid B Rubber (1.18)
gasket by end pair of M3 screws; can
M3(orx 0,5-6H screws (part number02-113355 ) to junction box be fitted to terminal strip.
A, according Connections
(part number
to model 186006)
type) 2 lenses in coverto solenoid A
Anti-rotation tab ensures
Connections
2 each end to (or B, according
Anti-rotationto model
correcttype )
orientation of cove r
tab ensures
Connections to solenoid B Rubber gasket
correct to junction
orientation boxr
of cove
solenoid (orBA, according Rubber gasket to junction box
1.according
For DC coils the
to model 2 lenses in cover
type)negative lead(s) must be connected to the terminal(s) marked +. When using 3-wire incom-
(or A,
toing
model type)to double solenoid valves 2 lenses in cover
28,50
leads (ex. common 30,00 neutral) the inner pair of terminals must be interconnected.
(1.12)
1. For DC coils the +ve ing leads to double (1.18)solenoid 2. For correct light indica- terminals are common with
1. For DC coils the must
lead(s) +ve be connecteding leads tovalves
double solenoid
(i.e. 2. For correct
common neutral) light
tion indica- solenoid
of energized terminals are common
each withof solenoid
outer pair
lead(s) must2. For correct light indication of energized solenoid ensure that solenoid
tion of energized leads are correctly connected:
each outer light
pair of solenoid
tobe
theconnected valves
terminal(s) marked +. (i.e. common
the inner neutral)
pair of terminals
Anti-rotation
ensure
tab ensures
solenoid
that solenoid leads terminals according to the
terminals are common with each outer pair of solenoid terminals
ensure thatare according to the side with +according
mark.
to the terminal(s)
When marked
using
Connections to +.
3-wire the
incom- inner pair
mustof terminals
be interconnected.
correct orientation cove r leads
solenoid
ofcorrectly connected: terminals
light side with to the
+ mark.
When using 3-wire solenoid B
incom- must be interconnected. are correctly
Rubber gasket to junction box connected: light side with + mark.
(or
DINA, according
43650 Connector
to model type) 2 lenses in cover

DIN 43650 Connector Ø6–10 mm (0.24–0.40) Recptacle Voltage 51(2.01)


1. For DCCable
coils thediameter
+ve range: Øing 6-10 mm
Ø6–10 leads
(0.24-0.40)
to double
mm (0.24–0.40) solenoid Recptacle2. For correct (AC or DC) terminals51(2.01)
light indica-
Voltage are common with 18 sq. 27
DIN 43650 Cable
Connector
diameter range: Ø,5–1,5 mm2 (0.0008– (1.06)
Wirebesection
lead(s) must range:
connected 5-1.5(i.e.
Øvalves mm2 (0.0008-0.0023
common neutral) in2)tion of energized solenoid
(AC or DC) each outer pair
18 of
sq. solenoid27
(0.71)
Cable diameter range: Ø,5–1,5 mm2 (0.0008–
0.0023 ofin2) terminals according (1.06)
to the terminal(s)
Wire marked
section
Terminals: +.
range: the inner
Screw pair
Type terminals ensure that solenoid leads (0.71) to the 1,5
Wire
Whensection
usingrange:
3-wire
Terminals: incom- 0.0023
must in2)
be interconnected. are correctly connected: light side with + mark.
Type of protection: IEC144 class
Screw typeIP65, when plugs areCoils fitted correctly12-24
to the valves with Seal interface 1,5 (0.06)
Terminals: Screw type (suppled with plugs)
seals Coils 12-24
with lights 100-125 (0.06)
Type of protection: IEC144 class IP65, whenin place. Seal
Type of protection: with lights 100-125 200-240 M3
IEC144 class IP65, when tted correctly to thread 30,5 sq. 5,5
200-240 12 DC M3 51(2.01)
Connector
Connector can be
can positioned
be positioned tted(0.24–0.40)
the correctly
valves withtointerfaceRecptacle Voltage thread 30,5 sq. (1.20) 5,5 27 (0.22)
DIN 43650 Connector Ø6–10 mm 12 DC
coils with 24 DC 51(2.01)
18 sq.
Connector at
Cable
can beintervals
at90°
90
diameter
0 positioned
intervals
range:
onon
valve the valves
by
valve by with
sealsinterface
(supplied with plugs)
coils with lights 24 (AC
DC or DC)
98-240 VDC
(1.20) 18 sq. (0.22)
(0.71) (1.06)
27
at 90° intervals on valve bycontact holder
re-assembling Ø,5–1,5 mm2
seals (supplied
in (0.0008–
with plugs)
place. (0.71) (1.06)
re-assembling
re-assembling contact holder
0.0023 into
in2) lights 98-240 VDC200-240 VDC 1,5
intocontact
Wire section range: holder
appropriate positionin place. (0.06)
1,5
intoTerminals: appropriate
appropriate
insideposition position inside
connector housing. Screw type connector 200-240 VDC Seal
Coils 12-24 (0.06)
housing.
inside connector housing. with lights 100-125 Seal
M3
Type of protection: IEC144 class IP65, when 5.5
200-240 thread
M3 30.5 sq. 26,5
tted correctly to thread 30,5 27,5
(1.20)
sq.26,5 (0.22)
5,5
AC DC with
Connector can be positioned Surge Protector bipolar 12 DC (1.08) (1.04)
(0.22)
the valves with interface 27,5 (1.20)(1.04) 22,5
ACLEDDCand
at 90° intervals with
on varistor
Surge
valve drop-off
by Protector delay
seals app with plugs)
(supplied coils with 24 DC (1.08) (0.88)
lights AC/DC w/ Rect.
98-240 &
VDC Surge 22,5
ACre-assembling3ms.
DC withbipolar The
Surgecontact energy
Protector
LED holder
and in the in
varistor coil is restrict-
place. (0.88)
AC/DC w/ Rect. & Surge 200-240 VDC
LEDed
into appropriate
bipolar andbyvaristor
the varistor.
position
inside connector housing. AC/DC with Rect. & Surge . bridge3ms rectifier
The energy in the coil is . 3ms
The energyrestricted
in the coilbyisthe varistor and varistor drop-off
operatingdelay appmax.
current 3ms1. 5 A 26.5
operating
operating current
current max.
max. 1. 5 A
1.5A 27.5 (1.04)
restricted by the varistor (1.08)
27,5 26,5
[]
(1.08) (1.04) 22.5
1 [] (0.88)
22,5
1 AC DC with Surge Protector (0.88)
AC/DC w/ Rect. & Surge
bipolar LED and varistor
. 3ms 1+
The energy in the coil is 1+
operating current max. 1. 5 A
restricted by the varistor
[]
1 []
[]
2 2-
2 T T 2- 9
T T 1+
Installation Dimensions

Mounting Surface

When a subplate is not used, a machined pad must be provided for mounting. The pad must be flat within
0.01 mm per 100 mm (0.0001” per 1”) and smooth within 0.8 µm.

The interface conforms to ISO 4401-AB-03-4A (size 03) plus location pin hole. ANSI/B93.7M (and NFPA) size 03
CETOP R35H4.2-03, plus location pin hole. DIN 24340 Form A6, plus location pin hole.

Dimensional tolerance = ± 0.2 (0.008) except where otherwise stated.

Prior to installing a valve, ensure that both valve and mounting surface are clean and free from burrs.

ISO 4401 gives dimensions in mm. Inch conversions are accurate to 0.01” unless stated.
#10-24 UNC-2B is optional.

70.0 (2.75) min Mass, approx. kg (lb)


Mass, Approx. kg (lb)
40.5 ± 0.1 (1.594 ± 0.004)
“U” “F”
30.2 (1.890) WFDG4V-3S (DC) coils coils
Single sol. valve 1.6 1.8
21.5 (3.5) (4.0)
(0.85)
Double sol. valve 2.2 2.3
12.7 (4.8) (5.0)
(0.5) 0.75 ± 0.1
(0.03 ± 0.004 ) “U” “F”
WFDG4V-3S (AC) coils coils
5.1 Single sol. valve 1.5 1.6
(0.20) T
(3.3) (3.5)
15.5 Double sol. valve 1.8 2.0
25.9 (0.61) A B
(1.01) (4.0) (4.4)
31.0 ± 0.1 31.75 ± 0.1
(1.22 ± 0.004) (1.25 ± 0.004)
48.0
(1.89)
min.
P

4 holes, M5-6H x 12.0


(0.47) min. full thread depth
4 ports . (0.25dia)

4/2017

You might also like