Hydrokraft Open Loop Piston Pumps

Technical Catalog

PVX
Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Code
Form Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Basic Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
No Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DF Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DQ Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ES Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
HG Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
FE Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Special Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Combination Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Examples for Combination units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Pump Specifications
US . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Metric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Performance Curves
Performance Curves, Outlet Flow & Inlet Power, Shaft Input Power, 066 to 250 Series . . . . . . . . . 21
Operating Data: Theoretical Bearing Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Operating Data: Typical Drain Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Controls
DF, LR Pressure Compensator/Power Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DQ Mooring Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
FE, HG Manual Displacement Adj. Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Electric Motor Displacement Control ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Pressure Signal Displacement Control DP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Proportional Valve Displacement Control SP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

2 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Table of Contents
(cont.)

Pump Dimensions *
PFXS 066. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
PFXS 090. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
PFXS 130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
PFXS 180. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
PFXS 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
PVXS 066 - 250 DF, Two Stage Pilot Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
PVXS 066 - 250 DF, with Load Sensing Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
PVXS 066 - 250 LR, with Pressure Limiter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
PVXS 066 - 250 ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
PVXS 066 - 250 DP, with Prop. Pilot Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
PVXS 066 - 250 SP, with Prop. Pilot Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Thru - drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Splined Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
SAE4 - Bolt Mounting, Installation Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Application Data
Fluid Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

* Dimensions - PVXS-066 to 250 DQ/HG/FE ask for special drawings.

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 3
Introduction

• Axial piston pumps • Oversize shafts and • "Building block" design AVAILABLE DISPLACEMENT
SIZES
with swashplate bearings. gives these pumps a
design for reliable wide range of 66 ccm
• Rotating and pressure
operation and long life. application. 90 ccm
loaded parts are
• Pressure up to 420 pressure balanced. • Fast response times. 130 ccm
bar. Rated speed up 180 ccm
• Integrated pilot pump,
to 1800 min-1. Higher filter and pressure AVAILABLE REPLACEMENT
speeds possible. relief valves available. UNIT DISPLACEMENT SIZES
250 ccm

Displacement controls: Typical Section of Open Loop PVX Pump


ES - Electric motor
displacement control Housing Cylinder
HG - Handwheel Block Control
displacement control Piston
(Special feature)
FE - Screw adjustment
Valve
control (Special feature) Plate
DF - Pressure
compensator controlled
DQ - Mooring control
LR - Power control with
pressure limiter
SP, SM - Displacement
proportional to electric
signal
DP - Displacement
proportional to pressure
signal
Shaft Swash Piston
Plate

Dimensional information listed in this catalog is subject to change without notice.

4 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Fixed & Variable
Displacement Pumps

"X" Series

Form Page
The following 48-digit coding system has been Some characters are already filled out on the
developed to identify all of the configuration options following pages. For such characters there is
for the "X" series (Open Loop) fixed and variable no option available.
displacement pumps. Use this model code to
specify a unit with the desired features. All 48-digits Explanation for each character can be found
must be present when ordering. You may want to as follows:
photocopy the matrix below to ensure that each CHARACTER PAGE
number is entered in the correct box. If adjustments Basic Pump Model Code 1...23 6
other than the standard setting (character 40 ... 43)
Control Options 24...39 7 - 15
or special features (character 44 ... 48) are needed,
Customer Adjustment Specification 40...43 7 - 15
please provide the information when ordering.
Special Features 44...46 16
Design Number 47...48 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
P X – M 1 S V A
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
1 0

SPECIFY NON STANDARD ADJUSTMENT BELOW

SPECIFY SPECIAL FEATURE BELOW

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 5
Model Code
Open Loop Pumps

“X" Series - Basic Pump

P * X * — * * * M * * * * * * 1 * * * S V * A #

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

1 Pump 10 11 Mounting Flange 14 15 Thru-Drive Options 22 Yoke Position Indicator


P – Open Loop Pumps 02 – ISO 3019/2-125A2HW 00 – None 0 – No position indicator
04 – ISO 3019/2-160A2HW 0A – SAE A V – Visual position indicator
2 06 – ISO 3019/2-200A2HW 0B – SAE B P– Position sensor
Displacement
* See Chart Below 0C – SAE C M – Sensor w/visual indicator
F – Fixed 0P – Pilot pump (8cm3/r)
V – Variable 12 Rotation Direction (PVX only) 23 Surface Finish
3 Pump Series R – Right Hand [CW] *** See Chart Below A – Blue painted
L – Left Hand [CCW]
X – “X” Series ** See Chart Below 16 Main Ports 24 Add Control Model
(was 20 design) 1 – SAE ports - metric bolts Code
13 Adjustment Stops
4 Configuration Code (characters 24...43) on
0 – No Stop 17 Main Port Orientation the following pages
S – Single Unit 4 – Mechanical Adjustment
R – Rear Unit A – Axial (in-line rear)
Stop Side A
R – Radial (side ports)
5
(PVX only)
Separator 5 – Mechanical Adjustment 18 19 Main Drive Shaft
Stop Side B
6 7 8 Displacement End
(PVX only)
cm3/r 6 – Mechanical Adjustment 01 – ISO straight key
066 – 66 cm3/r [4.0 in3/rev] Stops Side A and B 02 – ISO spline
090 – 90 cm3/r [5.5 in3/rev] (PVX only)
20 Drive Shaft Seal
130 – 130 cm3/r [7.9 in3/rev]
180 – 180 cm3/r [11.0 in3/rev] NOTE: Configuration
250 – 250 cm3/r [15.3 in3/rev] S – Single shaft seal
4 is used as max.
??? – Non-Standard
Adjustment on Side A.
Displacement (PFX 21 Seal Material
Only) 5 is used as min.
V – Viton**
Adjustment stop side A.
9
Basic Standard 6 is the combination of
M – Metric 4 and 5 together

*MOUNTING FLANGE OPTIONS AVAILABLE 066 090 130 180 250

ISO 3019/2-125A2HW • •
ISO 3019/2-160A2HW • •
ISO 3019/2-200A2HW •

**ROTATION DIRECTION 066 090 130 180 250

Right Hand • • • • •
Left Hand • • • •

***THRU-DRIVE OPTIONS 066 090 130 180 250

SAE A • • • • •
SAE B • • •

6 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps

“X" Series - No Control

0 0 0 0 0 A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

24 25 Control Type 30 Extra Functions 35 Pilot Oil Filter 38 Electric Motor Type

00 – No Control 0 – Not Required 0 – Not Applicable 0 – No Electric Motor


(For PFX only)
31 Pressure Control 36 Venting Valve 39 Control Voltage
26 Displacement Options 0 – Not Applicable 0 – Not Applicable
Adjustment Options 0 – Not Applicable
0 – Not Applicable 37 No Position Monitoring 40 41 42 43
Customer
32 33 34 Power Control Adjustment Specifications
0 – No Position Monitoring
27 28 Electronic Controls
000 – Not Applicable) 0000 – None
00 – Not Required
44 Special Features
29 Yoke Displacement Zone Add special feature
A – Single Side of Center “A” description (characters
44...46) on page 16 if
required.

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 7
Model Code
Open Loop Pumps

“X" Series - DF Control

D F 0 0 0 A * * 0 0 0 0 * 0 0 * * * * * #

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

24 25 Control Type 31 Pressure Control 37 Position Monitoring 40 41 42 43 Customer

DF – Pressure Compensator Options 0 – No Position Monitoring Adjustment Specification


0 – Not Applicable 0000 – None
26 Displacement F – Remote Port Only 38 Electric Motor Type ???? – Yes (final number will
Adjustment Options K – Electro Proportional 0 – No Electric Motor be assigned by Eaton.
0 – Not Applicable Relief Valve- Specify on table
Incl. Electr. Card 39 Control Voltage of below)
27 28 Electronic Controls Venting Valve
32 33 34 Power Control 44 Special Features
00 – Not Required 0 – Not Applicable
000 – Not Applicable B – 110 AC 50 HZ/ Add special feature
29 Yoke Displacement Zone 120 AC 60 HZ description (characters
35 Pilot Oil Filter 44...46) on page 16 if
A – Single Side of Center “A” D – 220 AC 50 HZ/
0 – Not Applicable 240 AC 60 HZ required.
30 Extra Functions G – 12 VDC
36 Venting Valve J – 24 VDC
0 – Not Required
1 – Load Sensing Extra 0 – Not Applicable
Function 1 – With Solenoid Valve

*CUSTOMER ADJUSTMENT SPECIFICATIONS


Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500 -
Mech. Stop Side A L/min Qmax
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Qmin
(used as min Adjustment Stop Side B)
Pressure Control Main Stage bar 20 -
Pressure Control Pilot Valve bar 19
Load Sense p bar 15 <15 bar not possible

8 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps

“X" Series - DQ Control

D Q 0 0 0 C 0 * 0 0 0 0 * 0 0 * * * * * #

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

24 25Control Type 31 Pressure Control 37 Position Monitoring 40 41 42 43 Customer

DQ – Mooring Control Options 0 – No Position Monitoring Adjustment Specification


0 – Not Applicable 0000 – None
26 Displacement F – Remote Port Only 38 Electric Motor Type ???? – Yes (final number will
Adjustment Options K – Electro Proportional 0 – No Electric Motor be assigned by Eaton.
0 – Not Applicable Relief Valve– Specify on table
Incl. Electr. Card 39 Control Voltage of below)
27 28 Electronic Controls Venting Valve
32 33 34 Power Control 44 Special Features
00 – Not Required 0 – Not Applicable
000 – Not Applicable B – 110 AC 50 HZ/ Add special feature
29 Yoke Displacement Zone 120 AC 60 HZ description (characters
35 Pilot Oil Filter 44...46) on page 16 if
C – Over Center D – 220 AC 50 HZ/
0 – Not Applicable 240 AC 60 HZ required.
30 Extra Functions G – 12 VDC
36 Venting Valve J – 24 VDC
0 – Not Required
0 – Not Applicable
1 – With Solenoid Valve

MOORING CONTROL AVAILABLE ON THE FOLLOWING FRAMES


Available Not Available
066 *
090 *
130 *
180 *
250 *

*CUSTOMER ADJUSTMENT SPECIFICATIONS


Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500 -
Mech. Stop Side A L/min Qmax
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Qmin
(used as min Adjustment Stop Side B)
Pressure Control Main Stage bar 20 -
Pressure Control Pilot Valve bar 90

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 9
Model Code
Open Loop Pumps

“X" Series - LR Control

L R 0 0 0 A * * * * * 0 * 0 0 * * * * * #

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

24 25 Control Type 31 Pressure Contro 37 Position Monitoring 41 42 43 Customer

LR – Power Control Options 0 – No Position Monitoring Adjustment Specification


0 – Not Applicable 0000 – None
26 Displacement F – Remote Port Only 38 Electric Motor Type ???? – Yes (final number will
Adjustment Options K – Electro Proportional 0 – No Electric Motor be assigned by Eaton.
0 – Not Applicable Relief Valve– Specify on table
Incl. Electr. Card 39 Control Voltage of below)
27 28 Electronic Controls Venting Valve
32 33 34 Power Control 44 Special Features
00 – Not Required 0 – Not Applicable
??? – KW at 1500 rpm B – 110 AC 50 HZ/ Add special feature
29 Yoke Displacement Zone 120 AC 60 HZ description (characters
35 Pilot Oil Filter 44...46) on page 16 if
A – Single Side of Center “A” D – 220 AC 50 HZ/
0 – Not Applicable 240 AC 60 HZ required.
30 Extra Functions G – 12 VDC
36 Venting Valve H – 24 VDC
2 – Pressure Limiter Extra
Function 0 – Not Applicable
3 – Load Sense & Pressure 1 – With Solenoid Valve
Limiter Extra Function

*CUSTOMER ADJUSTMENT SPECIFICATIONS


Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
Mech. Stop Side A L/min Qmax
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Qmin
(used as min Adjustment Stop Side B)
Pressure Control Main Stage bar 20
Pressure Control Pilot Valve bar 90
Load Sense p bar 15 <15 bar not possible

10 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps

“X" Series - ES Control

E S * 0 0 A 0 * 0 0 0 0 0 * * 0 * * * * #

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

24 25 Control Type 29 Yoke Displacement Zone 36 Venting Valve 40 41 42 43 Customer

ES – Electric Motor A – Single Side of Center “A” 0 – Not Applicable Adjustment Specification
Displacement 0000 – None
30 Extra Functions 37 Position Monitoring ???? – Yes (final number will
26 Displacement be assigned by Eaton.
0 – Not Required A –4 Limit Switches
Adjustment Options B – 8 Limit Switches Specify on table
M – Electric Motor - 31 Pressure Control P – 4 Limit Switches below)
Fast Response* Options w/Sensor
44 Special Features
N – Electric Motor - 0 – Not Applicable T – 8 Limit Switches
Medium Response* w/Sensor Add special feature
P – Electric Motor - 32 33 34 Power Control description (characters
Slow Response* 38 Electric Motor Type 44...46) on page 16 if
000 – Not Applicable
2 – Motor With Brake (IP-54) required.
27 28 Electronic Controls 35 Pilot Oil Filter 3 – Motor Without Brake
00 – Not Required 0 – Not Applicable (Explosion Proof)
39 Control Voltage of
Venting Valve
0 – Not Applicable

Response Time (sec) for Zero to max. Displacement


SIZE 066/090 130/180 250
Frequency 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Fast 7 6 18 15 15 13
Medium 24 20 35 29 30 25
Slow 38 32 54 45 48 40

**CUSTOMER ADJUSTMENT SPECIFICATIONS


Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
Mech. Stop Side A L/min Qmax
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Qmin
(used as min Adjustment Stop Side B)
Displacement Adjusted to… cm3/rev. ~50% Qmax
Position Monitoring Switch 1 L/min 0
2 L/min 95% of Qmax <95% not possible
3 L/min
4 L/min
5 L/min
6 L/min
7 L/min
8 L/min

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 11
Model Code
Open Loop Pumps

“X" Series - HG Control

H G 0 0 0 A 0 0 0 0 0 0 0 0 0 0 * * * * #

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

24 25 Control Type 29 Yoke Displacement Zone 35 Pilot Oil Filter 39 Control Voltage of

HG – Handwheel A – Single Side of Center “A” 0 – Not Applicable Venting Valve


Displacement Control 0 – Not Applicable
30 Extra Functions 36 Venting Valve
26 Displacement 40 41 42 43 Customer
0 – Not Required 0 – Not Applicable
Adjustment Options Adjustment Specification
0 – Not Applicable 31 Pressure Control 37 Position Monitoring 0000 – None
Options 0 – No Position Monitoring ???? – Yes (final number will
27 28 Electronic Controls be assigned by Eaton.
0 – Not Applicable
00 – Not Required 38 Electric Motor Type Specify on table
32 33 34 Power Control below)
0 – No Electric Motor
000 – Not Applicable
44 Special Features

Add special feature


description (characters
44...46) on page 16 if
required.

*CUSTOMER ADJUSTMENT SPECIFICATIONS


Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
Displacement Adjusted to... L/min Qmax

12 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps

“X" Series - FE Control

F E 0 0 0 A 0 0 0 0 0 0 0 0 0 0 * * * * #

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

24 25 Control Type 30 Extra Functions 36 Venting Valve 41 42 43 Customer

FE – Screw Adjustment 0 – Load Sensing 0 – Not Applicable Adjustment Specification


Displacement Control Extra Function 0000 – None
37 Position Monitoring ???? – Yes (final number will
26 Displacement 31 Pressure Control be assigned by Eaton.
0 – No Position Monitoring
Adjustment Options Options Specify on table
0 – Not Applicable 0 – Not Applicable 38 Electric Motor Type below)
0 – No Electric Motor
27 28 Electronic Controls 32 33 34 Power Control 44 Special Features

00 – Not Required 000 – Not Applicable 39 Control Voltage of Add special feature
Venting Valve description (characters
29 Yoke Displacement Zone 35 Pilot Oil Filter
0 – Not Applicable 44...46) on page 16 if
A – Single Side of Center “A” 0 – Not Applicable required.

*CUSTOMER ADJUSTMENT SPECIFICATIONS


Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
Displacement Adjusted to... L/min Qmax

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 13
Model Code
Open Loop Pumps

“X" Series - DP Control

D P * 0 0 A 0 0 0 0 0 * 0 0 0 0 * * * * #

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

24 25 Control Type 29 Yoke Displacement Zone 35 Pilot Oil Filter 39 Control Voltage of

DP – Pressure Signal A – Single Side of Center “A” 0 – Not Applicable Venting Valve
Adjustment V – Filter with Visual 0 – Not Applicable
Displacement Control 30 Extra Functions Indicator
E – Filter with Electrical 40 41 42 43 Customer
0 – Not Required
26 Displacement Indicator Adjustment Specification
Adjustment Options 31 Pressure Control 0000 – None
36 Venting Valve
G – Mounting Interface Options ???? – Yes (final number will
CETOP 3 Only 0 – Not Applicable 0 – Not Applicable be assigned by Eaton.
H – Remote Port G 1/4 Specify on table
J – Proportional Relief Inc. 32 33 34 37 Position Monitoring
Power Control below)
Electronics 000 – Not Applicable 0 – No Position Monitoring
44 Special Features
27 28 Electronic Controls 38 Electric Motor Type Add special feature
00 – Not Required 0 – No Electric Motor description (characters
44...46) on page 16 if
required.

*CUSTOMER ADJUSTMENT SPECIFICATIONS


Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500 -
Pilot Pressure bar 60
Mech. Stop Side A L/min Qmax
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Qmin
(used as min Adjustment Stop Side B)

14 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps

“X" Series - SP Control

S P * * * A 0 0 0 0 0 * 0 0 0 0 * * * * #

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

24 25 Control Type 29 Yoke Displacement Zone 36 Venting Valve 40 41 42 43 Customer


SP – Proportional Valve A – Single Side of Center “A” 0 – Not Applicable Adjustment Specification
Adjustment 0000 – None
Displacement Control 30 Extra Functions 37 Position Monitoring ???? – Yes (final number will
0 – Not Required 0 – No Position Monitoring be assigned by Eaton.
26 Displacement Specify on table
Adjustment Options 31 Pressure Control 38 Electric Motor Type below)
C – With CETOP 3 Prop Valve Options 0 – No Electric Motor
44 Special Features
KDG4V 3 0 – Not Applicable
F – With CETOP 5 Prop Valve 39 Control Voltage of Add special feature
32 33 34 Power Control Venting Valve description (characters
27 28 Electronic Controls 44...46) on page 16 if
000 – Not Applicable 0 – Not Applicable
03 – ER 9.3 - 10 (CETOP 3) required.
04 – ER 9.4 - 10 (CETOP 5) 35 Pilot Oil Filter
V –Filter with Visual Indicator
E – Filter with Electrical
Indicator

*CUSTOMER ADJUSTMENT SPECIFICATIONS


Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500 -
Pilot Pressure bar 60 -
Mech. Stop Side A L/min Qmax
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Qmin
(used as min Adjustment Stop Side B)
Max. Stop by Control Side A L/min 95% Qmax EI Card Adjustment Refer to EI card Manual
done by customer
Min. Stop by Control Side A L/min 0+/-2.5% EI Card Adjustment Refer to EI card Manual
done by customer
Ramp Time 0 A For 100% Stroke sec 0 EI Card Adjustment Refer to EI card Manual
done by customer
Ramp Time A 0 For 100% Stroke sec 0 EI Card Adjustment Refer to EI card Manual
done by customer
Preset Input Signals S1....S4 L/min - EI Card Adjustment Refer to EI card Manual
done by customer

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 15
Model Code
Open Loop Pumps

“X" Series - Special Features

* * * 1 0

44 45 46 47 48

44 45 46 Special Features

000 – None
*** – Defined by Eaton
47 48 Design Number

10 – Design Number

16 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Combination Units

* * * C — * * * * * * * * * * * * * * * * * * * *

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

H C 8 1 * * * * * * * * * *

26 27 28 29 30 31 32 33 34 35 36 37 38 39

1 Combination Unit 11 12 13 Second 19 20 Third Control Type 24 25 Fourth Control Type

P – Pump Displacement cm3/r 00 – No Control (for Fixed 00 – No Control (for Fixed


T – Transmission Pump 066 – 66 cm3/r [4.0 in3/rev] Displacement Only) Displacement Only)
M – Motor 090 – 90 cm3/r [5.5 in3/rev] DF – Pressure Compensator DF – Pressure Compensator
130 – 130 cm3/r [7.9 in3/rev] LR – Power Control LR – Power Control
2 Displacement 180 – 180 cm3/r [11.0 in3/rev] ES – Electric Motor Control ES – Electric Motor Control
F – Filled 250 – 250 cm3/r [15.3 in3/rev] HG – Handwheel HG – Handwheel
V – Variable 360 – 360 cm3/r [22.0 in3/rev] Displacement Control Displacement Control
500 – 500 cm3/r [30.5 in3/rev] FE – Screw Adjustment FE – Screw Adjustment
3 Pump Series 750 – 750 cm3/r [45.8 in3/rev] Displacement Control Displacement Control
W – “W” Series SM – Servo Adjustment SM – Servo Adjustment
14 15 Second Control Type Displacement Control - Displacement Control -
(was 30 design)
X – “X” Series 00 – No Control (for Fixed Mech Feedback Mech Feedback
(was 20 design) Displacement Only) DP – Pressure Signal DP – Pressure Signal
DF – Pressure Compensator Displacement Control Displacement Control
4 Combination Unit LR – Power Control SP – Proportional Valve SP – Proportional Valve
ES – Electric Motor Control Displacement Control Displacement Control
C
HG – Handwheel
21 22 23 Fourth 26 27 28 29 Assembly
5 Separator Displacement Control
FE – Screw Adjustment Displacement cm3/r Numbers
6 7 8 First Displacement Control 000 – Not Required HC81 – Defined By Eaton
Displacement cm3/r SM – Servo Adjustment 066 – 66 cm3/r [4.0 in3/rev]
Displacement Control - 090 – 90 cm3/r [5.5 in3/rev] 30 31 32 33 34 35 36 37 38 39
066 – 66 cm3/r [4.0 in3/rev] Mech Feedback 130 – 130 cm3/r [7.9 in3/rev] Assembly Numbers
090 – 90 cm3/r [5.5 in3/rev] DP – Pressure Signal 180 – 180 cm3/r [11.0 in3/rev]
130 – 130 cm3/r [7.9 in3/rev] Defined By Eaton
Displacement Control 250 – 250 cm3/r [15.3 in3/rev]
180 – 180 cm3/r [11.0 in3/rev] SP – Proportional Valve 360 – 360 cm3/r [22.0 in3/rev]
250 – 250 cm3/r [15.3 in3/rev] Displacement Control 500 – 500 cm3/r [30.5 in3/rev]
360 – 360 cm3/r [22.0 in3/rev] 750 – 750 cm3/r [45.8 in3/rev]
500 – 500 cm3/r [30.5 in3/rev] 16 17 18 Third
750 – 750 cm3/r [45.8 in3/rev] Displacement cm3/r
9 10 First Control Type 000 – Not Required
00 – No Control (for Fixed
066 – 66 cm3/r [4.0 in3/rev] • For a combination of • Charge and Pilot Pump
Displacement Only)
090 – 90 cm3/r [5.5 in3/rev] two or more units fill through drive option
DF – Pressure Compensator
130 – 130 cm3/r [7.9 in3/rev] out this Combination must be specified on
LR – Power Control
180 – 180 cm3/r [11.0 in3/rev] Model Code. the rear unit of the
ES – Electric Motor Control
250 – 250 cm3/r [15.3 in3/rev] • Start with the biggest combination (as a
HG – Handwheel
360 – 360 cm3/r [22.0 in3/rev] size unit for the first special feature).
500 – 500 cm3/r [30.5 in3/rev] displacement. Front and middle units
Displacement Control •
750 – 750 cm3/r [45.8 in3/rev] shall have the through
FE – Screw Adjustment • For each unit included
Displacement Control in this combination, a drive option of the
SM – Servo Adjustment separate model code following unit in the
Displacement Control - must be chosen. Use combination.
Mech Feedback the form on page 4.
DP – Pressure Signal
Displacement Control
• Character 26 to 39 will
SP – Proportional Valve be P/N of the
Displacement Control combination. This
number will be defined
by Eaton and provided
in the order
acknowledgement.

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 17
Model Code
Examples for
Combination Units

Example 1: Combination
of two open loop pumps
Model Code Front Unit PVWF-500M08R0001R02SVMASPC03A0000000000000000010
Model Code Rear Unit PVXR-250M07R0001R02SVMASPC03A0000000000000000010
Model Code Combination Unit PVWC-500SP250SP0000000000HC81**********

Example 2: Combination
of one closed loop - and
two open loop pumps
(For other product
model codes refer to the
according catalog)
Mode Code Front Unit TVWF-500M08R0000H1R02SVMA20SPC03C00000000E000H000000010
Model Code Middle Unit PVWM-250M07R0001R02SV0ADF000A0000000000000000010
Model Code Rear Unit PFXR-130M02R00P1A02SV0A00000A0000000000000000010
Model Code Combination Unit TVWC-500SP250DF1300000000HC81**********

18 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Specifications -
US

MODEL 66 90 130 180 250

Design Swashplate - Axial piston pump


Type of mounting Flange or foot-mounted. tandem is foot mounted only
Pipe connection SAE Flange B psi 1 1/2" = 3000 2" = 3000 2 1/2" = 3000 2 1/2" = 3000 3 1/2" = 500
A 1" = 6000 1" = 6000 1" = 6000 1 1/4" = 6000 1 1/4" = 6000
Direction of rotation Clockwise when viewing shaft end of pump
Counterclockwise available on request
Speed range nmin rpm 150
nmax 1800
Installation position Optional, see mounting information
Ambient temperature range min °F -4
max 122
Weight m lb 121 165 234 251 467
Mass of inertia J lb ft2 0.38 0.38 1.068 1.068 3.465

HYDRAULIC CHARACTERISTICS

Nominal pressure (100% duty cycle) pN psi 5000


Input pressure p1min psi 12.5 abs
p1max psi 725
Maximum pressure to DIN 24312 p2max psi 6090
Hydraulic fluid Hydraulic oil to DIN 51524 part 2. Refer to section Application Data-Fluid Recommendations
Hydraulic fluid temperature range min °F -13 (on startup)
max 194
Viscosity range for continuous operation min cSt 10
max cSt 75
Maximum permissible start viscosity max cSt 1000
Filtering ISO 4406 18/15/13
Maximum geometric n= 1500 rpm Vg in3 4.1 5.5 7.9 11.0 15.2
displacement n= 1800 rpm
Maximum geometric n= 1500 rpm Qg USgpm 26 36 52 71 99
pump flow n= 1800 rpm 32 43 62 86 119
Case pressure pv max psi max. 7.2psi over p1. pmax = 58 abs.

DRIVE

Maximum driving torque - single unit M1 Single lb.ft. 325 444 640 887 1233
(p2 max., = 100%)
Maximum power consumption - single unit P1 Single hp 93 126 182 254 355
(p2 max., = 100%; n= 1800 rpm)
Maximum driving torque limited to M1 Comb. lb.ft. 2x325 2x444 2x640 2x887 2x1233
splined shaft only - comb. unit

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 19
Pump
Specifications -
Metric

MODEL 66 90 130 180 250

Design Swashplate - Axial piston pump


Type of mounting Flange or foot-mounted. tandem is foot mounted only
Pipe connection SAE/Flange B psi 1 1/2" = 3000 2" = 3000 2 1/2" = 3000 2 1/2" = 3000 3 1/2" = 500
A 1" = 6000 1" = 6000 1" = 6000 1 1/4" = 6000 1 1/4" = 6000
Direction of rotation Clockwise when viewing shaft end of pump
Counterclockwise available on request
Speed range nmin min-1 150
nmax 1800
Installation position Optional, see mounting information
Ambient temperature range min °C -20
max 50
Weight m kg 55 75 106 114 212
Mass of inertia J kg m2 0.016 0.016 0.045 0.045 0.146

HYDRAULIC CHARACTERISTICS

Nominal pressure (100% duty cycle) pN bar 350


Input pressure p1min bar 0.85 abs
p1max bar 50
Maximum pressure to DIN 24312 p2max bar 420
Hydraulic fluid Hydraulic oil to DIN 51524 part 2. Refer to section Application Data-Fluid Recommendations
Hydraulic fluid temperature range min °C -25 (on start up)
max 90
Viscosity range for continuous operation min cSt 10
max cSt 75
Maximum permissible start viscosity max cSt 1000
Filtering ISO 4406 18/15/13
Maximum geometric n= 1500 min-1 Vg cm3 66 90 130 180 250
displacement n= 1800 min-1
Maximum geom. n= 1500 min-1 Qg L/min 99 135 195 270 375
pump flow n= 1800 min-1 118 162 234 324 450
Case pressure pv max bar max. 0,5 bar over p1. pmax = 4 bar abs.

DRIVE

Maximum driving torque - single unit M1 Single Nm 440 600 868 1202 1671
(p2 max., = 100%)
Maximum power consumption - single unit P1 Single kW 69 94 136 189 265
(p2 max., = 100%; n= 1800 min-1)
Maximum driving torque limited to M1 Comb. Nm 2x440 2x600 2x868 2x1202 2x1671
splined shaft only - comb. unit

20 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Performance
Curves -
066, 090, 130,
180, 250 Series

Outlet Flow and Theoretical Volumetric and Overall Efficiencies


Power Consumption

hp
kW 350 vol.
250 tot.
100
300 tot for 100 % Vg
L/min PFX/PVX 90
USgpm 400 tot for 50 % Vg
200
250 80
100 250
tot for 25 % Vg
Theoretical Power Consumption P

70
80 300 150 200
180 60
Efficiency (%)
Effective Outlet Flow

50
60 150
200 100
40
130
40 100
30
90
100 50 20
20 066 50

10

0 0 0 0
0 100 200 300 400 bar 0 100 200 300 400 bar

0 1000 3000 5000 5800 psi 0 1000 2000 3000 4000 5000 5800 psi
Operating Pressure Operating Pressure

Typical at 1500 min-1 with anti-wear oil at 40 cSt For Calculation: Peff = Pth/ tot
Single displacement pumps: PFX,PVX

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 21
Performance Pump size 066
Curves - 10 5
Operating Data:
Theoretical Bearing Life Time

Basic Rating Life L10 [h]


066, 090, 130,
180, 250 Series -1
1000 min

1500 min -1

1800 min -1
10 4

3
3 x 10
bar 50 100 200 300 400

At maximum displacement
and various speeds. psi 725 1450 2900 4350 5800
Operating Pressure

Pump size 090 Pump size 130


10 5 10 5

-1
Basic Rating Life L10 [h]

-1 1000 min
1000 min
Basic Rating Life L10 [h]
-1
1500 min
-1
1500 min 1800 min -1

1800 min -1
10 4 10 4

3 3
3 x 10 3 x 10
bar 50 100 200 300 400 bar 50 100 200 300 400

psi 725 1450 2900 4350 5800 psi 725 1450 2900 4350 5800
Operating Pressure Operating Pressure

Pump size 180 Pump size 250


10 5 10 5
Basic Rating Life L10 [h]
Basic Rating Life L10 [h]

-1 -1
1000 min 1000 min

1500 min -1 1500 min -1

1800 min -1 1800 min -1


10 4 10 4

3
3 x 10 3 x 10 3
bar 50 100 200 300 400 bar 50 100 200 300 400

psi 725 1450 2900 4350 5800 psi 725 1450 2900 4350 5800
Operating Pressure Operating Pressure

22 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Performance
Curves -
Operating Data:
Typical Drain Flow from an
Open-Loop Pump Based on USgpm L/min PFX/PVX180
1500 r/min and 35cSt
16

4.0 15
14
3.5 13
USgpm L/min PFX/PVX066/090 3
12
3.0 11 3.0
11
10 2
10
2.5 2.5
9 3 9
8 1
8
2.0 7 2.0
Drain Flow

7
6 2
1.5 6
5 1.5
1 5
4 4
1.0 1.0
3 3
2 2
0.5 0.5
1 1
0 0 0 0
0 100 200 300 bar 0 100 200 300 bar

0 1000 2000 3000 4000 5000 psi 0 1000 2000 3000 4000 5000 psi
Operating Pressure Operating Pressure

USgpm L/min
USgpm L/min
4.0 PFX/PVX130 4.0
PFX/PVX250
14 14
3.5 13 3.5 13
3 3
12 12
3.0 3.0
11 11
2 2
10 10
2.5 2.5
9 9
1
8 8
2.0 2.0
7 7
1
6 6
1.5 1.5
5 5
4 4
1.0 1.0
3 3
0.5 2 0.5 2
1 1
0 0 0 0
0 100 200 300 bar 0 100 200 300 bar

0 1000 2000 3000 4000 5000 psi 0 1000 2000 3000 4000 5000 psi
Operating Pressure Operating Pressure

1 PFX and PVX models at 2 PVX in pressure cutoff 3 PVX in pressure cutoff
maximum displacement (PVX mode (flow of pilot stage is mode (flow of pilot stage is
models with type FE, HG or discharged separately) discharged in case)
ES controls i.e. no control oil
flow)

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 23
Controls -
DF, LR Pressure
Compensator/
Power Control
“X” Series - Open loop pump

Energy saving hydraulic LR The p/Q variations see the model or 6 in combination with
drives are possible with characteristic curve coding and circuit customer adjustment
pressure compensated is a hyperbola. For diagrams. The maximum specifications position
and/or power controlled constant speed the drive flow of the pump can be 40-43 for the set values).
pumps, especially in torque, i.e. the power limited mechanically to This solution is also
combination with the used, is held constant. between 50% and 100% recommended for
load-sensing option. The power hyperbola can by screw. very rough operating
DF The system pressure be continuously adjusted As an additional option conditions and the
remains constant for between Pmin and the maximum (or need of a very exact
the entire volume flow Pmax. Pmin is given by minimum) flow can also repeatability over a long
rate. System pressure the minimum set value be limited by a spacer time period. The setting
can be set either of control’s main stage inside the control must be defined before
manually, hydraulically (app. 20 bar) and power cylinder (position ordering and cannot
or electronically. The loss of the pump. number 13 in be modified during
standard Hydrokraft Both controllers can be model coding, operation.
pressure compensator combined with another options 4, 5

Response Time (ms)(Vnull to Vmax)


is pilot operated and or with additional
very stable. options, for possible 200
250

Typical controller action


(Closing/opening the directional control valve WV)
Q Qmax or Qmin Qmax
CH - 50mm ID x 2 meters C 100
H WV 130/180

066/090

0
0 100 200 300 400 bar

2000 4000 6000 psi


p
Operating Pressure
S
100
Response Time (ms)(Vnull to Vmax)

250

130/180
Pressure compensator response times
Up Down
Outlet 066/090
pressure 50
p2
Tu
Swashplate
yoke angle Tu Tg Tg

y 0,9 y max.
0
0 100 200 300 400 bar
T u= time lag t
T g= compensating time
2000 4000 6000 psi
Operating Pressure

24 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
DF, LR Pressure
Compensator/
Power Control
“X” Series - Open loop pump

DF Pressure compensator
DF000A ...
Control valve adjustable
mechanically, electrically Alternatively
or remote port only
Mechanical Electrical Remote port
X1 adjustment adjustment only
+Q

..DF000A00.. ..DF000A0K.. ..DF000A0F..

Minimum pressure
Qmax approximately 20 bar (280 psi)

A B p

LR Power control with


overriding pressure
limiter LR000A2 ...
Pressure control pilot
valve adjustable
mechanically, electrically
Alternatively
or remote port only
Mechanical Electrical Remote port
X1 adjustment adjustment only
+Q

..LR000A20.. ..LR000A2K... ..LR000A2F...

Qmax
A B p

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 25
Controls -
DF, LR Pressure
Compensator/
Power Control
“X” Series - Open loop pump

DF Pressure Control valve adjustable


compensator with mechanically, electrically or
load sensing remote port only
DF000A1 ...
X1
X2 Alternatively
Mechanical Electrical Remote port +Q
adjustment adjustment only

..DF000A10.. ..DF000A1K.. ..DF000A1F..

p
Qmax

A B

LR Power control with Pressure control pilot valve


load sensing and adjustable mechanically,
pressure limiter electrically or remote port
LR000A3 ... only

X1 Alternatively
X2
Mechanical Electrical Remote port
adjustment adjustment only +Q

..LR000A30.. ..LR000A3K.. ..LR000A3F..

Qmax
A B p

26 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
DQ Mooring
Control
“X” Series - Open loop pump

The DQ-control is a The DQ-control is only As an additional option This solution is also
pressure control with available for sizes 66, (90 the maximum (or recommended for
overcenter operation on request), 130 and 180 minimum) flow can be very rough operating
(2 quadrants). It can ccm/rev. limited by a spacer conditions and the
be used eg. for Like the standard inside the control need of a very exact
counterbalanced Hydrokraft pressure cylinder (position repeatability over a long
systems or applications compensator this control number. 13 in model time period. The setting
where reverse flow pilot operated and very coding, options 4, 5 or 6 must be defined before
from the system can stable. For performance in combination with ordering and cannot
drive the pump in data/response time customer adjustment be modified during
reverse (negative please refer to the specifications position operation.
pump angle) such DF-control. 40-43 for the set values).
as a hydraulic motor.

Alternatively
Mechanical Electrical Remote port
X1 adjustment adjustment only

..DQ000A00.. ..DQ000A0K.. ..DQ000A0F..

Minimum pressure
approximately 20 bar (280psi)
+Q

Qmax

A B

-Q

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 27
Controls -
HG Manual
Adjustment
Displacement
Control FE
“X” Series - Open loop pump

FE The FE - control is HG The HG-control is The maximum (and/or customer adjustment


a displacement control a displacement control minimum) flow can be specifications position
where the pump flow where the pump flow limited by a spacer 40-43 for the set values).
is adjusted by a screw. can be adjusted by a inside the control The setting must be
handwheel. cylinder (position defined before ordering
number 13 in model and cannot be modified
coding, options 4, 5 or 6 during operation.
in combination with

+V

0 to + Vmax
displacement

28 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
Electric Motor
Displacement
Control ES
“X” Series - Open loop pump

The unit is used for The response times No pressure/power


stepless adjustment. from zero to maximum limiter possible.
It has a three phase depends on the chosen Explosion protection
electric servo motor, ration and the speed of versions are also
worm gearing and a the servo motor (this available.
switch box with 4 means that during
and 8 limit switches operation the response
for different positions. times are not variable.
A potentiometer is
also available. +V

Response time from 0 to +V


maximum displacement

M
B
L
PVX Response Times ES - Control
THEORETICAL RESPONSE TIME (SEC) FOR MAX. DISPLACEMENT CHARACTER IN MODEL CODE POS. 26

Size 066 090 130 180 250 250


Freq. Hz 50 60 50 60 50 60
Fast 7 6 18 15 15 13 M
Medium 24 20 35 29 30 25 N
Slow 38 32 54 45 48 40 P

Response time from 0 to +Qmax

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 29
Controls -
Pressure Signal
Displacement
Control DP
“X” Series - Open loop pump

The output flow of the The DP-control can be Pressure limiter or customer adjustment
pump is proportional used for steepless flow power limiter override specifications position
to the pilot pressure control with standard not available ( or such 40-43 for the set values).
A separate pilot oil requirements for and other options please This solution is also
circuit is necessary. dynamic and precision. refer to PVW-Series ). recommended for
From this the control No feedback signal As an additional option very rough operating
pressure is reduced to is needed, an optical the maximum (and/or conditions and the
the desired set value indicator recommended minimum) flow can be need of a very exact
by means of a suitable (position 22 in model limited by a spacer repeatability over a long
pressure control valve coding, option “V”). inside the control time period. The setting
(with P -T line ) and A pilot oil filter can be cylinder (position must be defined before
throttle in P - line 0.8 Ø mounted in line between number 13 in model ordering and cannot
(0.03 in). pump and control coding, options 4, 5 or 6 be modified during
(position 35 in model in combination with operation.
coding, option “V” or
“E”).

P T P T A B

M8

D1
P T A B

A pSt T P T A B
100%
Q max

Qmax

S B L

PVX Response Times DP - Control


RESPONSE TIME (SEC)
W/ 12 L/MIN PILOT OIL FLOW PILOT PRESSURE PST
SIZE (STANDARD) BAR 10 20 30 40 bar
066/090 0.7 60 Pilot pressure
130/180 0.9 60 The output flow of the pump is proportional
250 1.1 60 to the pilot pressure

30 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
Proportional Valve
Displacement
Control SP
“X” Series - Open loop pump

The SP control operates The proportional As an additional option This solution is also
a hydrostatic drive and valve and servo piston the maximum (and/or recommended for
works without throttle transform the output minimum) flow can be very rough operating
losses within electrically signal of the control card limited by a spacer conditions and the
adjustable limits. This to the desired setting. inside the control need of a very exact
is done by controlling This results in a very cylinder (position repeatability over a long
delivery flow with precise and dynamic number 13 in model time period. The setting
electrical swashplate control. Pressure limiter coding, options 4, 5 or 6 must be defined before
angle feedback (electr- override available on in combination with ordering and cannot
closed-loop control). request. Power limiter customer adjustment be modified during
All control values are override not available specifications position operation.
recorded as an electrical (for such and other 40-43 for the set values).
signal and lead back options please refer
to the control card. to PVW series).

M St

p St1
P T
Q

A B +100%

0
0 or 10 V
4 20 mA
Electric input signal

A B L1/L2

PVX RESPONSE TIMES SP - CONTROL


PROPORTIONAL VALVE PILOT PILOT OIL CONTROL RESPONSE
OIL FLOW PRESSURE PST ELECTRONICS TIME UNIT SIZE SERVO PISTON
L/min (Amp. Card) 0 < > Vmax Diameter Stroke Volume
(Usgpm) bar (psi) [ms] cm3 mm (in) mm (in) cm3 (in3)
Medium Response 60 (857) 250 066 / 090 40/30 (1.57/1.18) 28 (1.10) 15,4 (0.939)
KDG4V3-2C20NMUH760 12 (3.17) 60 (857) ER 9.3-10 350 130 / 180 55/38 (2.16/1.49) 35 (1.37) 43,5 (2.654)
(CETOP 3) 60 (857) 550 250 70/50 (2.76/1.97) 43,5 (1.71) 81 (4.942)
High Response ON REQUEST
(CETOP 5)

The ER9.3-10 and ER 9.4-10 ( for High Response ) digital Amplifier cards are optimized for use with the SP-Control. Please ask
for separate Documentation. Software is available for parameter setting and storing (database function). Contact Eaton to
request free of charge manual - and software CD.

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 31
Pump
Dimensions -
PFXS 066

120

246
26
0
Dimensions in mm
68
175 16 210
8 155
L5
L3 right
MB MA M14 cw

41 +0.2 B 160 Ø18


L2 80
Center bore
DM12 DIN332
58 4xM10-20deep
120
35 150
(180)

Port A
1", 6000psi

154 27.8
A
L1
57.2
68
(25)
W40x1.25x M12-20deep
Ø38 k6
10aDIN 5480 Ø125 h8 L5 Port B
10 h9
58 1 1/2", 3000psi
Center bore
DM12 DIN332 L2 B
69.8
218 56 15 Ø38
(367) M12x25deep

35.7

A System pressure port SAE 1’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 1 1/2‘’, 207 bar (3000 psi) Standard Displacement . . . . . . . . . . . . . . . . . . . . .66 ccm/rev
(L1) Drain port 7/8" – 14 UNF Reduced Displacement Available . . . . . . . . .55 or 44 ccm/rev
(L2) Ventilation port for vertical mounting M26x1.5
(L3) Ventilation port for vertical mounting G1/4 "
(shaft upwards)
(L5) Oil filling plug M26x1.5
(MA) Gauge port system pressure G1/4" DIRECTION OF ROTATION INPUT OUTPUT

(MB) Gauge port system pressure G1/4" Right Hand Rotation B A


(…) Normally plugged Left Hand Rotation A B

32 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PFXS 090

Dimensions in mm

120

246
26
0
217.5 68
175 16 210
8 155
L5
L3 right
M10 cw
MB MA

41 +0.2 160 Ø18


B
L2
80
Center bore
DM12 DIN332

58 4xM10-20deep 120
35 150 (180)

Port A
154 1", 6000psi
A
L1 27.8
68
57.2
W40x1.25x Ø38 k6 (25)
10aDIN 5480
L5 M12-20deep
Ø125 h8 10 h9
Center bore Port B
DM12 DIN332 58
L2 2", 3000psi
B 50
218 56 15
42.88
(367)
(372)
77.7 M12x25deep

A System pressure port SAE 1’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 2‘’, 207 bar (3000 psi) Standard Displacement . . . . . . . . . . . . . . . . . . . . .90 ccm/rev
(L1) Drain port 7/8" – 14 UNF Reduced Displacement Available . . . . . . . . . . . . . .75 ccm/rev
(L2) Ventilation port for vertical mounting M26x1.5
(L3) Ventilation port for vertical mounting G1/4 "
(shaft upwards)
(L5) Oil filling plug M26x1.5
(MA) Gauge port system pressure G1/4" DIRECTION OF ROTATION INPUT OUTPUT
(MB) Gauge port system pressure G1/4" Right Hand Rotation B A
(…) Normally plugged Left Hand Rotation A B

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 33
Pump
Dimensions -
PFXS 130

Dimensions in mm

148

316
0
92
20
9
224
L2 L1 L1.1
right
cw
L1 B
200 53.5 -0.2 22

100
Center bore
DM16 DIN332
82
200 4xM12-20deep 150
265 40 185

Port B
50.8

35
A 88.9 Ø63

78
M12-20deep
L1.1 MA
W50x1.25x10a L2 L1 Port A
DIN 5480 Ø50 k6
Ø160 h8 27.8
14 h9
Center bore 68
DM16 DIN332
L1 57.2 Ø25
B
271 120 22
(505) M12-20deep

A System pressure port SAE 1’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 2 1/2‘’, 207 bar (3000 psi) Standard Displacement size 130 ...........................130 ccm/rev
(L1) Drain port M26x1.5 Reduced Displacement Available Size 130...115 or 94 ccm/rev
(L1.1) Oil filling plug 1 1/16”-12UNF
(L2) Ventilation port for vertical mounting G1/4" DIRECTION OF ROTATION INPUT OUTPUT
(MA) Gauge port system pressure G1/4" Right Hand Rotation B A
(…) normally plugged Left Hand Rotation A B

34 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PFXS 180

Dimensions in mm

316
16
92 148
20
9
224
B
L2 L1 L1.1
right
cw
L1
200 53.5 -0.2 B
22
100
Center bore
DM16 DIN332
82
200 150
4xM12-20deep
265 185
40
Port B
50.8
3

A
88.9 Ø63
78
L1.1 MA
Ø160 h8 L2 L1 M12-20deep
W50x1.25x10a Ø50 k6
DIN 5480 Port A
14 h9 31.8
68
Center bore
DM16 DIN332 L1
A
B Ø32 66.7
271 120 2
(505) M14-20deep

A System pressure port SAE 1 1/4’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 2 1/2‘’, 207 bar (3000 psi) Standard Displacement Size 180 ..........................180 ccm/rev
(L1) Drain port M26x1.5 Reduced Displacement Available Size 180............160 ccm/rev
(L1.1) Oil filling plug 1 1/16”-12UNF
(L2) Ventilation port for vertical mounting G1/4" DIRECTION OF ROTATION INPUT OUTPUT
(MA) Gauge port system pressure G1/4" Right Hand Rotation B A
(…) Normally plugged Left Hand Rotation A B

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 35
Pump
Dimensions -
PFXS 250

Dimensions in mm

187

403
0
117
25
10 280
L1
clockwise
L1
250 6 +0.2 26 250 +0.2
B
125
MB Center bore
DM20 DIN332
188 105 4xM16-32deep
330 50 230
Port B
350
69.8

A 120.7 Ø88
MA
90
M16-32deep
L1 L1.1
W62x1.25x10a L2
DIN5480 Ø65 k6 Port A
Ø200 h6 31.8
Center bore 18 h9
80
DM20 DIN332

B 66.7 Ø32
341 164 22
(644) M14-24deep

A System pressure port SAE 1 1/4’’, 415 bar (6000 psi) Non-Standard Displacements:
B System pressure port SAE 3 1/2‘’, 35 bar (500 psi) Standard Displacement ........................................250 ccm/rev
(L1) Drain port M26x1.5 Reduced Displacement Available.......222, 208 or 194 ccm/rev
(L1.1) Oil filling plug 1 5/16”-12UN
(L2) Ventilation port for vertical mounting G1/4" DIRECTION OF ROTATION INPUT OUTPUT
(MA) Gauge port system pressure G1/4" Right Hand Rotation B A
(…) normally plugged Left Hand Rotation A B

36 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 37
Pump
Dimensions -
PVXS 066 - 250
DF, Two Stage
Pilot Valve

Side ports -
Pressure compensator
DF000A ...
1. Pilot valve (2nd Stage) View X
Port "A"
2. Pressure compensator 6000psi
(1st stage) L19

Dimensions in mm D10 L14

D11

Port "B" L13


X1 G1/4’’x12,5-deep; option for an additional pilot valve 3000/500psi
and/or discharge valve of the pressure compensator L11
L1 Two drain ports, one supplied plugged
L2 M18x1, 5x12-deep supplementary drain, or bleed plug. L12 D8
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards. D9
MA G1/4"x12.5-deep gauge port supplied plugged

DIRECTION OF ROTATION CONTROL INPUT OUTPUT

Right Hand Rotation To + Vmax B A


To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A

SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT


3000(500)PSI, INLET 6000PSI, OUTLET KG

066 1 1/2’’ 1’’ 55


090 2‘’ 1’’ 57
130 2 1/2’’ 1’’ 111
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226

SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12


h9

066 210 116 160 235 130 180 10 116 58 185 218 —
090 210 116 160 235 130 180 10 116 58 185 218 157.5
130 260 140 200 265 224 224 14 140 70 185 218 —
180 260 140 200 265 224 224 14 140 70 185 218 —
250 325 175 250 330 280 280 18 175 87.5 185 218 —

SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13


h8 k6 Light Execution SAE 475

066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF


090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF

38 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
B4 L1 L17
X1
B2 L2
L18
L9 orifice
L7 inside
H9 of the
24 control
L6 valve
X1
L1 D5
L1 L1 Size 090
MA D6
H8
H7 B
D12 0 H5
H6 +Vmax
D3

H3 Center bore
DM16 DIN332 L10
L16
B9 L8 L2 L15
B8 L5 M18x1.5-12deep L20
B5 L4 L3
B12

B11
B10 Splined shaft
Dim. See page 51

1
X
2
MA
A
L1 L1
L1
cw L3
H1
D2 k6
H2 H4 +0.2 D4 D1 h8
D13
L1

B7 h9
B3 B Size 090
B6
B1

SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9
+0.2

066 227 162 90 41 93 53 88 139 91


090 227 162 90 41 93 53 88 139 91
130 283 207 113 53.5 117 64 110 174 91
180 283 207 113 53.5 117 64 110 174 91
250 354 260 140 69 146 77 138 217 91

SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20

066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 50 10 72.5 245.6 245.6 31
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 50 10 72.5 245.6 245.6 31
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 50 12 72.5 316 309 33
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 50 12 72.5 316 309 33
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 56 — 72.5 403 403 35

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 39
Pump
Dimensions -
PVXS 066 - 250
DF, with Load
Sensing Valve

Side ports -
Pressure compensator
with Load Sensing
DF000A1 ...
1. Pilot valve (2nd Stage) View X
Port "A"
2. Pressure compensator 6000psi L19
(1st stage)
3. Flow valve

Dimensions in mm
D10 L14

D11
X1 G1/4’’x12,5-deep; option for an additional pilot valve
and/or discharge valve of the pressure compensator
L13
X2 G1/4’’x12,5-deep; load sensing pilot port Port "B"
L1 3000/500psi L11
Two drain ports, one supplied plugged
L2 M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed L12 D8
with the shaft input end pointing upwards.
MA G1/4"x12.5-deep gauge port supplied plugged D9

DIRECTION OF ROTATION CONTROL INPUT OUTPUT

Right Hand Rotation To + Vmax B A


To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A

SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT


3000(500)PSI, INLET 6000PSI, OUTLET KG

066 1 1/2’’ 1’’ 55


090 2‘’ 1’’ 57
130 2 1/2’’ 1’’ 111
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226

SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12


h9

066 210 116 160 235 130 180 10 116 58 185 218 —
090 210 116 160 235 130 180 10 116 58 185 218 157.5
130 260 140 200 265 224 224 14 140 70 185 218 —
180 260 140 200 265 224 224 14 140 70 185 218 —
250 325 175 250 330 280 280 18 175 87.5 185 218 —

SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13


h8 k6 Light Execution SAE 475

066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF


090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF

40 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
B4 L1 L17
B2 orifice
L2
L18 inside
of the
L9 control
L7 valves
H9
X1 Size 090
L6
X2
L1 D5
L1 L1
MA D6
H8
B
H7 D12 H5
0
H6 +Vmax
D3

H3 Center bore
DM16 DIN332
L10 L16
B9 L8 L2 D7 L15
B8 L5
M18x1.5-12deep
B5 L4 L3
B12

B11 Splined shaft


B10 Dim. See page 51
1 X

2 MA
A
3
L1

L1 L1 L3
D2 k6
D1 h8
cw D13
H1 L1
H4 +0.2 D4

H2
B Size 090

B7 h9
B3
B6
B1

SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9
+0.2

066 227 162 90 41 93 53 88 139 132


090 227 162 90 41 93 53 88 139 132
130 283 207 113 53.5 117 64 110 174 132
180 283 207 113 53.5 117 64 110 174 132
250 354 260 140 69 146 77 138 217 132

SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19

066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 50 10 67.5 245.6 245.6
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 50 10 67.5 245.6 245.6
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 50 12 67.5 316 306
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 50 12 67.5 316 306
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 56 — 70.5 403 403

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 41
Pump
Dimensions -
PVXS 066 - 250
LR, with Pressure
Limiter

B11
B10
Side ports -
Power Control LR 1
(with pressure limiter)
LR000A2 ... 2
1. Pilot valve (2nd Stage)
2. Pressure compensator
(1st stage) L1 L1
3. Constant power control
cw
Dimensions in mm H1
+0.2 D4
H2 H4

B7 h9
X1 G1/4’’x12,5-deep; option for an additional pilot valve B3
and/or discharge valve of the pressure compensator B6
L1
B1
Two drain ports, one supplied plugged
L2 M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
View X
MA G1/4"x12.5-deep gauge port supplied plugged Port "A"
6000psi L19
DIRECTION OF ROTATION CONTROL INPUT OUTPUT Port "B"
Right Hand Rotation To + Vmax B A 3000/500psi
To - Vmax A B
L11
Left Hand Rotation To + Vmax A B
To - Vmax B A
D10 L14
L12 D8
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT D11
3000(500)PSI, INLET 6000PSI, OUTLET KG 2 D9 D2
066 1 1/2’’ 1’’ 55
090 2‘’ 1’’ 57
L13
130 2 1/2’’ 1’’ 111 D1
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226

SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12


h9

066 210 116 160 235 130 180 10 116 58 185 218 —
090 210 116 160 235 130 180 10 116 58 185 218 157.5
130 260 140 200 265 224 224 14 140 70 185 218 —
180 260 140 200 265 224 224 14 140 70 185 218 —
250 325 175 250 330 280 280 18 175 87.5 185 218 —

SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13


h8 k6 Light Execution SAE 475

066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF


090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF

42 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
B4 L1 L20
B2 L2 L17 orifice
L18 inside
L9 of the
L7
control
H9 valves
L6
X1 D5 X1
L1
L1
MA D6
H8
B
H7 H5
H6 D12 0
+Vmax
D3 3

H3 Center bore
DM16 DIN332 L10 L16
B9 L8 D7 L15
L5 L2
B8 M18x1.5-12deep Size 090
B5 L4 L3
B12

Splined shaft
Dim. See page 51
X

MA
A

L1
L3
D2 k6
D1 h8 D13

L1
3

B Size 090

SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9
+0.2

066 227 162 90 41 93 53 88 139 91


090 227 162 90 41 93 53 88 139 91
130 283 207 113 53.5 117 64 110 174 91
180 283 207 113 53.5 117 64 110 174 91
250 354 260 140 69 146 77 138 217 91

SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20

066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 50 10 72.5 245.6 245.6 161
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 50 10 72.5 245.6 245.6 161
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 60 12 72.5 316 306 171
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 60 12 72.5 316 306 171
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 112 — 75.5 403 403 199.5

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 43
Pump
Dimensions -
PVXS 066 - 250
ES

Side ports -
Electric Motor
Displacement Control
ES*00A ...

Dimensions in mm

B4
L1 Two drain ports, one supplied plugged B2
L2 M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
MA G1/4"x12.5-deep gauge port supplied plugged
D14
L1
H8
DIRECTION OF ROTATION CONTROL INPUT OUTPUT H7
L1
Right Hand Rotation To + Vmax B A
To - Vmax A B D12
H6 MA D3
Left Hand Rotation To + Vmax A B
To - Vmax B A

H3 Center bore
DM16 DIN332
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT
3000(500)PSI, INLET 6000PSI, OUTLET KG

066 1 1/2’’ 1’’ 55 B9


090 2‘’ 1’’ 57 B8
130 2 1/2’’ 1’’ 111 B5
180 2 1/2’’ 1 1/4’’ 113 B12
250 3 1/2’’ 1 1/4’’ 226

SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12


h9

066 210 116 160 235 130 180 10 116 58 276.5 334.5 —
090 210 116 160 235 130 180 10 116 58 276.5 334.5 157.5
130 260 140 200 265 224 224 14 140 70 288.5 368.5 —
180 260 140 200 265 224 224 14 140 70 288.5 368.5 —
250 325 180 250 330 280 280 18 175 87.5 332.7 434.7 —

SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13 D14


h8 k6 Light Execution SAE 475

066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF 110.5


090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF 110.5
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF 110.5
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF 110.5
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF 123

44 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
L1 L16 B11
L2 L15 B10
L17
L9
L7

L6
D14
L1 D5
L1
D6
H7 L1
B cw
H5
0 H1
A D3 +Vmax
H4+0.2
H2
D4
Center bore
DM16 DIN332 L10

L8 L2 D7 B7 h9
L5 Size 090
M18x1.5-12deep B3
L4 L3 B6
Splined shaft B1
Dim. See page 51

L18
X
View X
Port "A"
6000psi
MA
A
D L
L1
D11
L3
D2 k6
D1 h8 L13
D13 Port "B" L11
3000/500psi
L1

L12 D8
B Size 090
D9

SIZE H1 H2 H3 H4 H5 H6 H7 H8
+0.2

066 227 162 90 41 93 53 122 168


090 227 162 90 41 93 53 122 168
130 283 207 113 53.5 117 58.5 165 214
180 283 207 113 53.5 117 58.5 165 214
250 354 260 140 69 146 77 198 262

SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18

066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 78 153.5 7245.6 245.6
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 78 153.5 245.6 245.6
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 100 175.5 316 306
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 100 175.5 316 306
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 88 163.5 403 403

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 45
Pump
Dimensions -
PVXS 066 - 250

X SSt
MA
A

Side ports - L1
Pressure Signal
Displacement Control L3 PSt1 T
DP*00A ... D2 k6
1. Pressure proportional valve D1 h8
D13
2. Pressure limiter
L1

Dimensions in mm
B
Size 090 L12
T G1/2’’ Tank port
SSt G3/4’’ Suction port of pilot pump
PSt G3/4’’ Port of pilot pressure
PSt1 Port of pilot pressure Size 006/090=M14x1.5 Splined shaft
Size 130/180=M16x1.5 Dim. See page 51
Size 250=G1/2’’(M22x1.5)
B4
L1 Two drain ports, one supplied plugged B2
L2 M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed 1
with the shaft input end pointing upwards. H9
MA G1/4"x12.5-deep gauge port supplied plugged
2

DIRECTION OF ROTATION CONTROL INPUT OUTPUT L1


Right Hand Rotation To + Vmax B A H8
To - Vmax A B MA
Left Hand Rotation To + Vmax A B H7 D12
To - Vmax B A H6
D3

SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT H3


3000(500)PSI, INLET 6000PSI, OUTLET KG

066 1 1/2’’ 1’’ 55


090 2‘’ 1’’ 57 B9 Cent
130 2 1/2’’ 1’’ 111 B8 DM1
B5
180 2 1/2’’ 1 1/4’’ 113 B12
250 3 1/2’’ 1 1/4’’ 226

SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12


h9

066 210 116 160 235 130 180 10 116 58 52 182.5 —


090 210 116 160 235 130 180 10 116 58 52 182.5 157.5
130 260 140 200 265 224 224 14 140 70 52 182.5 —
180 260 140 200 265 224 224 14 140 70 52 182.5 —
250 325 180 250 330 280 280 18 175 87.5 52 182.5 —

SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13 D14


h8 k6 Light Execution SAE 475

066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF 64


090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF 64
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF 88
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF 88
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF 88

46 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pilot pump View X
Port "A" B11
6000psi L19 B10

SSt

D10 L14
L1 L1
D11

T cw
L13 H1
H4 +0.2 D4
Port "B" H2
3000/500psi
L11

B7 h9
L12 B3
D8 B6
B1
Splined shaft
D9
Dim. See page 51

L15
L1 L16
L2
L22 L17
L18
L9 Cetop NG6
L7 DIN24340
PSt1
T
L6
L1 D5
D6 D14
MA
B
H5
+Vmax
PSt
D3

3
L10 H10

Center bore L8
DM16 DIN332 L5 L2 L20
Pilot pump View X
M18x1.5-12deep Size 090 L21
L4 L3 Port "A"
6000psi
SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11
+0.2

066 227 162 90 41 93 53 88 137 127 97 113


090 227 162 90 41 93 53 88 137 127 97 113
130 283 207 113 53.5 117 64 110 170 127 97 131
180 283 207 113 53.5 117 64 110 170 127 97 131
250 354 260 140 69 146 77 138 214 127 124 167

SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 L21 L22

066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 267 104 46 245.6 245.6 73.5 122.6 230.6
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 267 104 46 245.6 245.6 73.5 122.6 230.6
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 342 128 46 316 306 73.5 122.6 336
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 342 128 46 316 306 73.5 122.6 336
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 387 150 46 403 403 73.5 122.6 437

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 47
Pump
Dimensions -
PVXS 066 - 250

B2
Side ports - 1
Proportional Valve
Displacement Control
3
SPC03A.....E...
1. Proportional valve
2. Pressure limiter 2
3. Filter L1 L1

cw
Dimensions in mm H1
D4 H2
T G1/2” H3
Pst G1/2”
Mst G1/4” B3
B6
L1 Two drain ports, one supplied plugged B1
L2 B13
M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
Port "A" Port "B"
MA G1/4"x12.5-deep gauge port supplied plugged
0
L14 D10 L12 D8

D11 D9
DIRECTION OF ROTATION CONTROL INPUT OUTPUT 0
L13 L11
Right Hand Rotation To + Vmax B A
To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A

SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT


3000(500)PSI, INLET 6000PSI, OUTLET KG

066 1 1/2’’ 1’’ 55


090 2‘’ 1’’ 57
130 2 1/2’’ 1’’ 111
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226

SIZE B1 B2 B3 B4 B5 B6 B7 B8 B12 B13


h9

066 210 116 160 235 130 180 10 116 — 165


090 210 116 160 235 130 180 10 116 157.5 165
130 260 140 200 265 224 224 14 140 — 190
180 260 140 200 265 224 224 14 140 — 190
250 325 175 250 330 280 280 18 175 — 221

SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12


h8 k6 Light Execution

066 125 38 M12 — 7/8-UNF M22x1.5 M10 20 38 M12 24 25 M12 21 —


090 125 38 M12 18 7/8-UNF M22x1.5 M10 20 50 M12 24 25 M12 21 —
130 160 50 M16 22 1 1/16-UNF M26x1.5 M12 20 62 M12 20 25 M12 20 M20
180 160 50 M16 22 1 1/16-UNF M26x1.5 M12 20 62 M12 20 32 M14 20 M20
250 200 65 M20 26 1 1/16-UNF M33x2 M16 32 90 M16 32 32 M14 24 M24

48 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
L16
L15 Prop. Valve
L1 Filter with
electr.
12 L2 Contamination
130 173 Indicator
Pilot Pressure
Compensator

174 L18 PSt


L10
MSt
L9

L1 L1 L7 L1 D6 D5
L6
H8 MA
B
H7
H6 D12 0
+Vmax
H4 D3

Center bore
DIN332
L5 M18x1.5-12deep
B8 L8 L2 D7 only Size 090
B5 L4
B4 L3

Splined shaft
Dim. See page 51

MA View X
L19
A T
X T
L1
L3
D1 D2
D5
B7 B12
L1

B only Size 090


El. position indicator

SIZE H1 H2 H3 H4 H5 H6 H7 H8
+0.2

066 227 162 90 41 93 53 88 139


090 227 162 90 41 93 53 88 139
130 283 207 113 53.5 117 64 110 176
180 283 207 113 53.5 117 64 110 176
250 354 260 140 69 146 77 138 220

SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L18 L19 L20 L21

066 342 274 150 35 8 58 16 26 120 185 35.7 69.8 27.8 57.2 328 576 245.6 245.6 68 58
090 342 274 150 35 8 58 16 26 120 185 42.88 77.77 27.8 57.2 328 576 245.6 245.6 68 58
130 483 391 185 40 9 82 20 32 148 229 50.8 89 27.8 57.2 451 738 316 306 78 68
180 483 391 185 40 9 82 20 32 148 229 50.8 89 31.8 66.7 451 738 316 306 78 68
250 622 505 230 50 10 105 25 41 187 281 69.8 120.7 31.8 66.7 579 931 403 403 90 80

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 49
Pump
Dimensions - L3
PVXS Thru-Drive L2
22
Mounting, Thru-Drive Options
SAE “A” and SAE “B”

PVX 066 / 090


SAE “A” H
102 Ø82.58+0.03

10
106.4 L1
130 O-ring supplied
M10-20deep loose with PV pump
For SAE"A", splined shaft,
16/32 DP-9 teeth

L3
L2
22

PVX 130 / 180 / 250


SAE “A”

H
1 Ø82.58+0.03

For SAE"A",
splined shaft,
10 16/32 DP-9 teeth
106.4 L1
130 O-ring supplied
M10-18deep loose with PV pump

33

PVX 130 / 180 / 250


SAE “B”
D2
H7
D1 89.8 Ø101.6

For SAE"B",
splined shaft,
16/32 DP-13 teeth
89.8 9
146 12
B1 O-ring supplied
loose with PV pump

SIZE THROUGH SHAFT B1 D1 D2 L1 L2 L3 H

066/090 SAE “A” — — — 47 60 81 53


130/180 SAE “A” 224 M20-30 deep M12-20 deep 28 62 81 64
SAE “B” — — — — 62 81 64
250 SAE “A” 280 M24-38 deep M12-24 deep 28 56 91 77
SAE “B” — — — — 56 91 77

50 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
Splined Shafts
For Variable Displacement
Pumps (PVXS) Only

68
Size 066 / 090

W40x1.25x10a
DIN 5480

Center bore
DM12 DIN332 58

Size 130 / 180 78

W50x1.25x10a
DIN 5480

Center bore 68
DM16 DIN332

Size 250 90

W62x1.25x10a
DIN5480

Center bore
DM20 DIN332 80

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 51
Pump
Dimensions -
PVXS SAE 4-Bolt
Mounting Pads

DIM. CODE 61 SERIES CODE 62 SERIES


C ÿA
1 1/2" 2" 2 1/2" 3 1/2" 1" 1 1/4"
A 38 50 62 90 25 32 max
B 35,7 42,9 50,8 69,8 27,8 31,8
C 69,8 77,8 89 120,7 57,2 66,7
D D M12x20 M12x20 M12x20 M16x26 M12x18 M14x24
PFX / PVX 066 Inlet •
Outlet •
PFX / PVX 090 Inlet •
Outlet •
PFX / PVX 130 Inlet •
Outlet •
PFX / PVX 180 Inlet •
Outlet •
PFX / PVX 250 Inlet •
Outlet •

Thru-drive Shaft Output Torque


MAX. OUTPUT TORQUE, NM (LB.FT) Installation Drain
Pump Keyed Shaft Keyed Shaft Splined piping
Size Increasing Load Increasing Load Shaft
Shaft up
066 520 (383) 260 (190) 660 (485)
090 520 (383) 260 (190) 660 (485)
L2
130 720 (530) 360 (265) 900 (665)
180 720 (530) 360 (265) 900 (665)
250 1400 (1032) 1400 (1032) 2500 (1843)
L1

0,2 bar
(3 psi)
check

Shaft
down

L3

L1

0,2 bar
(3 psi)
check

52 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Application Data -
Fluid
Recommendations

Case Flushing Fluids Fluid Cleanliness Fluid Cleanliness


Requirements Pumps in the catalog are These pumps are correct balance of
A check valve must not primarily designed rated for anti-wear cleanliness, materials,
be used in the drain to operate with petroleum fluids with and additives for
pipe. The drain pipe conventional petroleum a contamination level protection against
must interminate below based hydraulic oil. of 18/15/13 per ISO wear of inclusion of air.
the oil level in the Alternative fluids and 4406. Operation in Essential information
reservoir. restrictions: fluids with levels more on the correct methods
For all other conditions • Fluid maintenance contamination than this for treating hydraulic
with low pressure <20 is critical to the is not recommended fluid is included in Eaton
bar (<300 psi) and low durability of all and may reduce the publication 561- "Vickers
flow (<10% of Qmax) hydraulic components, life of the pump Guide to Systemic
case flushing is required. and particularly so components. Fluids Contamination Control"-
with hydraulic pumps. other than petroleum, available from your
For operation with severe service cycles,
special fluids HFB and This becomes even local Eaton distributor.
more of a factor when or temperature extremes
HFC, case flushing is are cause for adjustment In this publication,
recommended. alternative fluids are filtration and cleanliness
used. All types of of these codes. Please
contact your Eaton levels for extending the
alternative fluids life of axial piston
Flushing Flow require extensive representative for
special duty cycle pumps and other
Flushing flow via the maintenance in order system components
pump case should be to maintain proper recommendations.
are listed. Included is an
>1% of maximum pump levels of water Eaton pumps, as excellent discussion of
flow. Maximum flushing content, acidity, well as any variable the selection of products
flow depends on case viscosity and displacement piston needed to control fluid
pressure. contamination. pumps, will operate condition.
with apparent
Notes: satisfaction in fluids up
to the rating specified Ordering Procedure
• All listed ratings are
here. Experience has When ordering please
based on the use of specify full model
a good quality fluid. shown, however, that
pump and hydraulic designation of items
• Alternative fluids have system life is not required; see "Model
a reduced tolerance optimized with high Codes" section of
for contamination over fluid contamination this catalog.
petroleum base fluids. levels (high ISO Note the following:
Good filtration is cleanliness codes).
therefore critical. • Designation of variable
Proper fluid condition displacement pumps
• The pumps will provide is essential for long must include the
exceptional life when and satisfactory life of supplementary
used with a good hydraulic components designation of the
quality clean fluid and systems. Hydraulic required control.
at the pump ratings fluid must have the
specified for that fluid.
FLUIDS
Max. Max. Recommended Max
Pressure Speed Seal Operating Bearing
Type Classification Bar rpm Material Temperature °C Life
Oil in Water Emulsion HFAE Not Rated 0
Water in Oil Emulsion HFB 250 1800 Fluorocarbon 49 50%
Water Glycol HFC 250 1800 Fluorocarbon 49 25%
Phosphate Ester HFDR 350/420 1800 Fluorocarbon 66 100%
Polyol Ester HFDU 350/420 1800 Fluorocarbon 66 100%

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 53
Notes

54 EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Notes

EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003 55
Eaton Eaton Eaton
14615 Lone Oak Road 20 Rosamond Road Dr.-Reckeweg-Str. 1
Eden Prairie, MN 55344 Footscray D-76532 Baden-Baden
USA Victoria 3011 Germany
Tel: 952 937-9800 Australia Tel: (49) 07221 682-0
Fax: 952 974-7722 Tel: (61) 3 9319 8222 Fax: (49) 07221 682-788
www.hydraulics.eaton.com Fax: (61) 3 9318 5714

© 2003 Eaton Corporation


All rights reserved

Vickers
Printed in USA
Document No. V-PUPI-TM004-E