You are on page 1of 3

gunt

WL 110.02
Plate heat exchanger

x 2E

Complete experimental set-up with supply unit WL 110, screen mirroring is possible on up to 10 end devices

Description Learning objectives/experiments

• parallel flow and counterflow op- allowing the flow direction to be re- • in conjunction with WL 110 supply unit
eration possible versed. This allows parallel flow or coun- · function and behaviour during opera-
• intuitive experiment execution via terflow operation. tion of a plate heat exchanger
touch screen · plotting temperature curves:
• integrated router for operation During experiments, temperature in parallel flow operation
and control via an end device and curves are plotted and displayed graph- in counterflow operation
for screen mirroring on up to 10 ically. The mean heat transfer coefficient · calculation of mean heat transfer
end devices: PC, tablet, smart- is then calculated as a characteristic coefficient
phone variable. · comparison with other heat ex-
• automatic identification of ac- changer types
cessories via RFID technology The accessory WL 110.02 is easily and
safely positioned on the worktop of the • PLC software specifically adapted to
The key feature of plate heat ex- WL 110 supply unit. Via RFID techno- the accessories used
changers is their compact design, in logy the accessories are automatically · learning module with theoretical fun-
which optimum use is made of all of the identified, the appropriate PLC software damentals
material for heat transfer. The pressed is loaded and an automatic system con- · device description
in profile on the plates creates narrow figuration is performed. The intuitive · guided experiment preparation
flow channels, in which significant turbu- user interface guides through the exper- · execution of the experiment
lence occurs. The turbulent flow allows iments. For tracking and evaluation of · graphical representation of the ex-
effective heat transfer even with low the experiments, up to 10 external perimental section with measured
flow rates and also has a self-cleaning workstations can be used simultan- values for temperature
effect. Plate heat exchangers are used eously using the local network via LAN · data transfer via WLAN/LAN for
in the food industry, offshore technology, connection. versatile external use of measured
refrigeration and domestic engineering. values and screenshots e.g. evalu-
Temperature sensors for measuring the ation in Excel
The plate heat exchanger WL 110.02 is inlet and outlet temperatures are loc-
made up of profiled plates with water ated at the supply connections of the
flowing through the spaces between WL 110. The supply of hot and cold wa-
them. These are one “cold” and one ter, the flow setting and the measure-
“hot” flow channel, in an alternating ar- ment of inlet and outlet temperatures
rangement. Part of the thermal energy are carried out via the supply unit.
of the hot water is transferred to the
cold water. The supply hose can be re-
connected using quick-release couplings,

G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email sales@gunt.de, Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 1/3 - 11.2021
gunt
WL 110.02
Plate heat exchanger

Specification

[1] plate heat exchanger for connection to WL 110


[2] parallel flow and counterflow operation possible
[3] six soldered plates
[4] recording of temperature using WL 110
[5] automatic identification of accessories via RFID
technology and use of the corresponding PLC soft-
ware
[6] experiment execution and display of the measured
values via touch screen (HMI)
[7] screen-mirroring: access to ongoing experiments
and their results from up to 10 end devices simul-
taneously via the local network
[8] hot and cold water supply from WL 110

1 plates, 2 water connections Technical data

6 plates, stainless steel


Heat transfer surface: 480cm2

LxWxH: 400x230x85mm
Weight: approx. 3kg

Scope of delivery

1 plate heat exchanger

1 plate with cold water, 2 plate with hot water; red: hot water, blue: cold water

User interface on the touch screen: temperature curve in counterflow operation

G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email sales@gunt.de, Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 2/3 - 11.2021
gunt
WL 110.02
Plate heat exchanger
Required accessories

060.11000 WL 110 Heat exchanger supply unit

G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email sales@gunt.de, Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 3/3 - 11.2021
Powered by TCPDF (www.tcpdf.org)