You are on page 1of 10

Which statement is true?

The S4 supports 16 threads per core


The SPARC M7 processor uses the fourth generation CMT Core, referred to as
S4 (*)
The SPARC M7 processor uses the fourth generation CMT Core, referred to as
S3.
The S3 supports 16 threads per core
 Incorrect. Please refer back to the lesson “SPARC M7 Processor Overview.”
(0/1) Points
2. Which two features are part of the SPARC M7 processor’s power management
features ?
(Choose all correct answers)
Dynamic Voltage Frequency Scaling (*)
Dynamic memory allocation
Voltage Acclimatization
power gating (*)
 Incorrect. Please refer back to the lesson “SPARC M7 Processor Overview.”
(0/1) Points
3. Which type of link is an inter-processor cache coherent connection?
SLINK
SP LINK
CLINK (*)
IL
 Correct!
(1/1) Points
4. What is the total amount of level 3 cache that the M7 processor supports?
32 Mbytes
64 Mbytes (*)
128 Mbytes
256 Mbytes
 Correct!
(1/1) Points
5. Which systems use the SPARC M7 processor?
(Choose all correct answers)
SPARC M6-32
SPARC T7-2 (*)
Oracle SuperCluster T5-8
SPARC T7-4 (*)
Oracle SuperCluster M7 (*)
 How does the M7 processor implement SSM within its silicon?
By improving the crytography performance within the M7 processor chip
By implementing 8 DAX units to function as co-processors (*)
By increasing the size of the instruction pipeline
By implementing increasing the cache size
 Correct!
(1/1) Points
7. Which response is the definition of a DAX?
(Choose all correct answers)
A co-processor chip that offloads the data compression and decompression functions from the
software threads
A co-processor with the M7 processor that offloads the data compression and decompression
functions from the software threads (*)
A memory control unit within the M7 processor
A memory control unit chip outside of the M7 processor (*)
 Incorrect. Please refer back to the lesson “SPARC M7 Processor Overview.”
(0/1) Points
8. Which is the function of the Mystic River ASIC?
Memory Buffer
I/O Hub (*)
Service Processor
Disk Controller
 Correct!
(1/1) Points
9. How many layers of cache does the SPARC M7 processor have?
1
2
3
4 (*)
 Incorrect. Please refer back to the lesson “SPARC M7 Processor Overview.”
(0/1) Points
10. How many virtual CPUs can the M7 support considering that each thread can be a virtual
CPU?
32
64
128
256 (*)

How many DIMM slots are supported by the M7 processor?


16 (*)
32
64
128
 Incorrect. Please refer back to the lesson “SPARC M7 Processor Overview.”
(0/1) Points
12. Which three statements are true about M7 processors?
(Choose all correct answers)
Each M7 processor provides coherency links, referred to as CLINKs (*)
CLINKS are used on both the M7 and T7 servers (*)
Level 4 cache is one of the most important processor enhancements
CLINKS provide for inter-processor connections (*)
SSM is also a common features with Intel Processors
 Incorrect. Please refer back to the lesson “SPARC M7 Processor Overview.”
(0/1) Points
13. Which type of DIMMs are supported by the M7 processor?
DDR5
DDR4 (*)
DDR3
DDR2
 Correct!
(1/1) Points
14. What enhancements to the SPARC M7 processor contribute to security at all
layers of the stack?
4 layers of cache
Increased password protection
Improvements to on-chip cryptography (*)
 Incorrect. Please refer back to the lesson “SPARC M7 Processor Overview.”
(0/1) Points
SPARC T7 Servers Overview
(Answer all questions in this section)
15. What are two benefits of NVMe?
(Choose all correct answers)
PCIe based SSD (*)
Lower performance than SAS
Higher performance than SAS (*)
Lower Performance than SATA
Higher performance than SATA

How many processor chips does the SPARC T7-2 server have?
1 SPARC M7 32-core 4.13Ghz CPU
2 SPARC M7 32-core 4.13Ghz CPUs (*)
4 SPARC M7 32-core 4.13Ghz CPUs
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
17. How many processor chips does the SPARC T7-1 server have?
1 SPARC M7 32-core 4.13Ghz CPU (*)
2 SPARC M7 32-core 4.13Ghz CPUs
4 SPARC M7 32-core 4.13Ghz CPUs
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
18. What is the maximum memory configuration in a SPARC T7-1 server?
16 DIMM slots with memory mezzanine (*)
32 DIMM slots with memory risers
64 DIMM Slots
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
19. What is the maximum memory configuration in a SPARC T7-4 server?
16 DIMM slots with memory risers
32 DIMM slots with memory mezzanines
64 DIMM slots (*)
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
20. What are two benefits of DIMM sparing?
(Choose all correct answers)
1 out of 16 DIMMs per socket can be spared (*)
2 out of 16 DIMMs per socket can be spared
Migration of contents from failing DIMM takes place, with minor impact on
performance
Migration of contents from failing DIMM takes place, with no visible impact on
performance (*)

Which components are located in a single T7-4 server processor module?


2 CPUs, 32 DIMM slots, 12 BoBs (*)
4 CPUs, 64 DIMM slots, 24 BoBs
4 drive bays, 2 IOHs, server processor module
8 drive bays, 4 IOHs, server processor module
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
22. How many processor chips does the SPARC T7-4 server have?
1 SPARC M7 32-core 4.13Ghz CPU
2 SPARC M7 32-core 4.13Ghz CPUs
4 SPARC M7 32-core 4.13Ghz CPUs (*)
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
23. Which can fail, yet allow the T7 servers continue to operate?
Single fan
Single power supply
Single fan and and single power supply (*)
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
24. In which two ways does being glueless impact the SPARC T7-2 and T7-4 servers?
(Choose all correct answers)
The processors are directly connected (*)
The processors are indirectly connected
The system directory is fine- grain interleaved in COs
The system directory is fine-grain interleaved in processors (*)
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
25. Which can fail, yet allow the T7 servers continue to operate and power on?
Single fan
Single power supply (*)
Single fan and and single power supply

Which components are located in a T7-4 server main module?


2 CPUs, 32 DIMM slots, 12 Bobs
4 CPUs, 64 DIMM slots, 24 BoBs
8 drive bays, 4 IOHs, server processor module (*)
4 drive bays, 2 IOHs, server processor module
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
27. What is the benefit of VersaBoot?
Boots the operating system from a versatile drive
Boots Solaris’s root filesystem from firmware-accessible storage
Boots Solaris's root filesystem from firmware-inaccessible storage (*)
 Incorrect. Please refer back to the lesson “SPARC T7 Server Overview.”
(0/1) Points
28. What is the maximum memory configuration in a SPARC T7-2 server?
16 DIMM slots with memory mezzanine
32 DIMM slots with memory risers (*)
64 DIMM slots
 Correct!
(1/1) Points
SPARC T7 Servers Installation
(Answer all questions in this section)
29. What piece of equipment is required when installing a SPARC T7-2 and
SPARC T7-4 server into a rack?
Lift (*)
Hex wrench
Hex screwdriver
 Incorrect. Please refer back to the lesson “SPARC T7 Server Installation.”
(0/1) Points
30. Which one of these SPARC T7 server installation hardware steps are in the
correct order?
Adjust the CMA, attach data and management cables to the server, and install
the server into a rack.
Install the server into a rack, attach data and management cables to the server,
and adjust the CMA. (*)
Install the server into a rack, adjust the CMA, and attach data and management
cables to the server.

What do you type to power on a SPARC T7server?


Start / system (*)
Root and changeme
Host and changeme
 Incorrect. Please refer back to the lesson “SPARC T7 Server Installation.”
(0/1) Points
32. What is the CMA?
Cable Management Arm (*)
Cable Movement Action
Connect Management System
 Correct!
(1/1) Points
33. What is the recommended number of people to install a SPARC T7 server?
1
2 (*)
3
 Correct!
(1/1) Points
34. Select two ways the boot process been enhanced from the conventional boot
process with the SPARC T7?
(Choose all correct answers)
VersaBoot, where the server is booted via a firmware-inaccessible storage
device, iSCSI or eUSB (*)
Fallback Boot, where the server is booted via an image stored on the SP (*)
RemoteBoot via a LAN-based floppy drive
TimedBoot, where you can set the system to boot via your iPhone alarm
 Incorrect. Please refer back to the lesson “SPARC T7 Server Installation.”
(0/1) Points
35. What is a key benefit of Automated Service Request (ASR)?
ASR provides installation self-service requests
ASR sends every possible fault or flaw messages to Oracle immediately for
service
ASR software resolves problems faster by automatically opening service
requests for Oracle's qualified server products when specific faults occur (*)

 Which one of these SPARC T7 server installation steps are in the correct order?
Prepare terminal access, turn on power to the SP, monitor the boot process via ILOM, and
power on the server and set up the operating system. (*)
Power on the server and set up the operating system, prepare terminal access, turn on power
to the SP, and monitor the boot process via ILOM.
Monitor the boot process via ILOM, power on the server and set up the operating system.
prepare terminal access, and turn on power to the SP.
 Incorrect. Please refer back to the lesson “SPARC T7 Server Installation.”
(0/1) Points
37. Which one of these preliminary SPARC T7 server installation steps are in the correct
order?
Review the SPARC T7 documentation, review the server specifications and site
requirements, and take safety and ESD precautions. (*)
Review the server specifications and site requirements, take safety and ESD precautions, and
review the SPARC T7 documentation.
Take safety and ESD precautions, review the server specifications and site requirements, and
review the SPARC T7 documentation.
 Correct!
(1/1) Points
38. Which resource are you required to use at a customer site for server installation?
Site Requirements
Product Documentation
EIS Installation Checklists (*)
 Incorrect. Please refer back to the lesson “SPARC T7 Server Installation.”
(0/1) Points
39. What is the password for root in your initial SP login?
root
changeme (*)
admin
default
 Incorrect. Please refer back to the lesson “SPARC T7 Server Installation.”
(0/1) Points
40. What do you type to login to the SP in a SPARC T7 server?
Start / system
Root and changeme (*)
Host and changeme

What are two options that can function as a systems console during the SPARC T7
installation?
(Choose all correct answers)
iPhone
ASCII terminal (*)
Workstation (*)
Kindle
 Incorrect. Please refer back to the lesson “SPARC T7 Server Installation.”
(0/1) Points
SPARC T7 Servers FRU CRU
(Answer all questions in this section)
42. In the T7-2, to remove the power supply backplane, you must:
Remove the memory risers, the air baffle, the drives, the power supply ribbon cable and
cover, and the bus bar screws.
Remove the memory risers, the air baffle, the power supplies, the power supply ribbon cable
and cover, and the bus bar screws. (*)
Remove the memory mezzanines, the air baffle, the power supplies, the power supply ribbon
cable and cover, and the bus bar screws.
 Correct!
(1/1) Points
43. Which three of these T7-4 server components are CRUs?
(Choose all correct answers)
Cable kit
Main module (*)
Rear IO module (*)
Processor module (*)
Rear chassis sub assembly
 Correct!
(1/1) Points
44. Which three of these T7-1 server components are CRUs?
(Choose all correct answers)
SAS SSD (*)
PCIe card (*)
Motherboard
Disk backplane
Memory mezzanine (*)
 Incorrect. Please refer back to the lesson “SPARC T7 Server FRU CRU.”
(0/1) Points
45. In the T7-4 where is the eUSB is located?
In the main module
On the rear IO board (*)
In the processor filler module

Which three of these T7-1 server components are FRUs?


(Choose all correct answers)
SAS SSD
DVD drive (*)
Motherboard (*)
Disk backplane (*)
Memory mezzanine
 Incorrect. Please refer back to the lesson “SPARC T7 Server FRU CRU.”
(0/1) Points
47. In the T7-2, to remove the fan cage assembly, you must:
Remove the memory mezzanines, remove the fans, remove the cables, pull the
fan cage assembly up out of the server.
Remove the memory risers, remove the fans, remove the cables, pull the fan
cage assembly up out of the server.
Remove the memory risers, remove the fans, remove the cables, remove the
screws that secure memory riser guide and pull it up out of the server, pull the
fan cage assembly up out of the server. (*)
 Incorrect. Please refer back to the lesson “SPARC T7 Server FRU CRU.”
(0/1) Points
48. Which three of these T7-2 server components are FRUs?
(Choose all correct answers)
DVD drive
Motherboard (*)
Disk backplane
Fan cage assembly (*)
Power supply backplane (*)
 Incorrect. Please refer back to the lesson “SPARC T7 Server FRU CRU.”
(0/1) Points
49. Which two of these T7-4 server components are FRUs?
(Choose all correct answers)
Cable kit (*)
Main module
Rear IO module
Processor module (*)
Rear chassis sub assembly
 Incorrect. Please refer back to the lesson “SPARC T7 Server FRU CRU.”
(0/1) Points
50. Which three of these T7-2 server components are CRUs?
(Choose all correct answers)
DVD drive (*)
Memory riser (*)
Disk backplane (*)
Fan cage asssembly
Power supply backplane

You might also like