You are on page 1of 1

GENERAL NOTES

°GENERAL NOTES AND TYPICAL STRUCTURAL DETAILS SHALL


APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED.
°ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST
APPLICABLE STANDARDS OR SPECIFICATIONS. ALL WORKS SHALL
CONFORM WITH THE BEST PRACTICE PREVAILING IN VARIOUS TRADES.
TYP-1 °THE CONTRACTOR WILL BE RESPONSIBLE FOR THE COORDINATION OF WORK
AMONG VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO INSURE
THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.

°DO NOT SCALE DRAWINGS, CALLED-OUT DIMENSIONS AND STANDARD CODE


Access Ladder REQUIREMENTS SHALL GOVERN OVER UNSCALED DRAWINGS.

°UNLESS SPECIFICALLY DETAILED ELSEWHERE CONTRACTOR SHALL FOLLOW


TYPICAL DETAILS AS SHOWN IN THESE DRAWINGS.

°THE CONTRACTOR IS GIVEN THE OPTION TO UTILIZE ALTERNATIVE METHODS


Ø48mm-5mm thk OF DESIGN AND ALTERNATIVE METHOD OF CONSTRUCTION AS DEEMED
LIFT 5 Diag. Face Brace
SUITABLE PROVIDE THAT SUCH OPTION IS IN COMFORMANCE WITH THE DESIGN
Ø48mm-5mm thk CONCEPT OF THE PROJECT AND IS COMPLIANCE WITH THE INFORMATION
GIVEN IN CONTRACT DOCUMENTS.
Midrail Guard
°ALL STRUCTURAL DIMENSIONS ARE IN METERS AND MILIMETERS
AND LEVELS ARE IN METERS AND MILIMETERS OTHERWISE NOTED.
Ø48mm-5mmthk
°EVERY SCAFFOLD SHALL BE OF GOOD CONSTRUCTION SOUND MATERIALS AND
LIFT 4 Standard Post STRENGTH FOR THE PURPOSE FOR WHICH IT IS INTENDED.
Ø48mm-5mm thk
°ALL MATERAILS AND PARTS OF SCAFFOLD NOT IN USE OR INTENDED FOR RE-USE
Standard Post SHALL BE KEPT UNDER GOOD CONDITION AND SEPARATE FROM OTHER MATERIALS
UNSUITABLE FOR SCAFFOLD.

°ALL MANUFACTURED SCAFFOLDS AND ITS ACCESORIES SHALL FOLLOW THE


Ø48mm-5mm thk MANUFACTURERS DESIGNS AND SPECIFICATION.
LIFT 3
Midrail Guard °ANY DAMAGED OR WEAKEND SCAFFOLD MEMEBERS FROM ANY CAUSES SHALL BE
Ø48mm-5mm thk IMMEDIATELY REPAIRED, REPLACED OR DISCARDED.
Diagonal Bracing
°SCAFFOLD SHALL NOT BE LOADED IN EXCESS OF THE WORKING LOAD FOR WHICH
THEY ARE INTENDED
Ø48mm-5mm thk LIFT 2 °SCAFFOLD SHALL BE ANCHORED OR SECURED TO PERMANENT OR RIGID
Outriger Bracing Ø48mm-5mm thk STRUCTURES. IN THE ABSENCE OF PERMANENT STRUCTURES GUYS AND
SWAY BRACING AND/OR OUTRIGGER SHALL BE USED.
(Add if necessary) Ledger
°GENERAL NOTES FOR GENERAL PROVISIONS, DESIGN AND STABILITY,
Ø48mm-5mm thk INSPECTION, ERECTION SHALL BE PROVIDED ALONG WITH THE
STRUCTURAL CALCULATION AND STRUCTURAL DRAWING
Putlog
LIFT 1
6mm thk Base Plate °ALL SCAFFOLDING MEMBER WHICH INCLUDES THE STANDARD POST,
LEDGER, PUTLOG, BRACING, ETC. SHALL CONFORM TO ASTM A106 Grade. B
50mm thk
Kicker Lift Sill/Sole Board
50mm thk
Sill/Sole Board
TYPICAL CONNECTION DETAIL

TYP-3
SIDE VIEW ELEVATION FRONT VIEW ELEVATION

TYP-2

Platform @ Every Level


TYP-1 FRONT VIEW TYPICAL DOUBLER COUPLER/
SWIVEL CLAMP

TYP-1 PLAN VIEW

TYP-2 SLEEVE COUPLER


TOP VIEW PLAN
TYPI-3 ISOMETRIC VIEW
SILL BOARD DETAIL
TYPI-1 BACK VIEW
A PROPOSED

02
S-101
SCAFFOLDING DETAILS
SCALE - NTS

DESIGNER PROJECT TITLE OWNER PROJECT NO. SHEET CONTENTS SHEET NO.

PROJECT NUMBER

Engr. KEANNE NEOL L. OLMEDO PROPOSED SCAFFOLDING UNILEVER PHILIPPINES Drawn by: DRAWING 02 S - 102
CIVIL/STRUCTURAL
Chckd by:
156 MARICK DRIVE, STO. DOMINGO, CAINTA, RIZAL ENGINEER
Tel.No. (02) 8960542 / (02) 86914623
PROJECT LOCATION Aprvd by: PAPER SIZE:A3