You are on page 1of 337

BILL NO.

2: MAIN BUILDING
SUB BILL NO.2.1 : SUBSTRUCTURE
ORIGINAL

Quantity Unit
Code Description

Bored Piles

A Allow for providing all plant and equipment on site for 1 Ls


the installation of the piles including moving the plant
and equipment about the site, the provision of
temporary supports as required during the execution of
the works and for removing the plant and equipment
from site on completion of the works

B Allow for submission of records in triplicate of all bored 1 Ls


piles installed, duly signed by the Contractor and
deliver to the Project Manager as the work proceeds

C Allow for the submission of a drawing showing the final 1 Ls


plan position of each pile reference by a serial number
and the levels of the bottom and top of each pile as
installed

Bored Tension Piles

Note:
Bored pile, 400mm diameter (656 no)

D Boring, 400mm diameter from basement level to 7,872 m


proposed bored pile level (12 m)

E Install temporary caison / liner as necessary and 656 no


subsequently remove

F Concrete filling (K-300), to 400mm diameter pile (12 m) 1,489 m3

G General reinforcing bar 13 mm diameter 101,914 kg

H General reinforcing bar 8 mm diameter 41,000 kg

I Remove surplus excavated material/soil disposal from 1,489 m3


site

J Backfill blind bore with excavated material m3

To Collection

Bored Piles (Cont'd)

Pile Testing

A Allow for providing and mobilizing all necessary 1 ls


equipment, materials and labour to carry out axial and
lateral load tests

B Carry out axial compressive loading test by Kentledge 1 no


method on 400mm diameter pile

C Carry out axial load test by the PDA test including 1 no


CAPWAP analysis on working pile size 400mm
diameter
D Carry out PIT test on working pile size 400mm 2 no
diameter ramdomly

E Clean up and remove load testing equipment from site 1 ls


on completion of the load testing works

F Allow for recording results and providing reports as 1 ls


specified

To Collection

SUBSTRUCTURE

Excavation

Note: The quantities given are the net volume, allowance for
additional excavation and backfilling to provide working space shall
be included in the unit rates

A Excavation for basement commencing from existing 381 m3


ground level

B Ditto for pile caps 987 m3

C Ditto for tie beams m3

D Ditto for ground slab (provisional) m3

Soil disposal and backfilling

E Remove surplus excavated material from site 652 m3

F Backfilling including compaction in layers to trenches 716 m3

Compacted sand bed

G 100mm thick compacted sand layer under basement 3,811 m2


slab

H Ditto for pile caps 363 m2

I Ditto for tie beams and ground slab m2

Lean concrete 1:3:5

J 50mm thick blinding layer under basement slab 3,811 m2


K Ditto for pile caps 363 m2

L Ditto for tie beams and ground slab m2

To Collection

SUBSTRUCTURE (Cont'd)

Termite treatment as specified

A Apply termite treatment 3,811 m2

Cut off pile heads

B Cut off precast spun pile heads 600mm diameter 656 no


including integration of reinforcement into pilecaps,
including cutting, bending rebar, filling top of pile and
cleaning, and disposal off site

Vibrated reinforced concrete K-300

C Pile caps 209 m3

Vibrated reinforced concrete K-350

D Tie beams 211 m3

E Basement slab 840 m3

F Ground slab 368 m3

Bar reinforcement; deformed high tensile BJTD-40,


including bending, cutting to length and supplying and
installing all tying wire, accessories and consumable

G General reinforcing bars in pile caps, 13 mm 25,701 kg

H Ditto; 10 mm diameter 1,175 kg

I General reinforcing bars in tie beams 31,412 kg

J General reinforcing bars in basement slabs 109,195 kg

K General reinforcing bars in ground slabs 47,798 kg

L General reinforcing bars in suspended beams 22,092 kg

To Collection

0.00 SUBSTRUCTURE (Cont'd)


Formwork

A To sides of pile caps 909 m2

B To sides of tie beams 803 m2

C To edges of basement slab 200mm high 467 m

D To edges of ground slab 100~200mm high 156 m

E To sides of suspended beams 1,008 m2

To Collection

COLLECTION

Page 6/Sub bill 2.1/1 Rp.

Page 6/Sub bill 2.1/2 Rp.

Page 6/Sub bill 2.1/3 Rp.

Page 6/Sub bill 2.1/4 Rp.

Page 6/Sub bill 2.1/5 Rp.


SUB BILL NO.2.1 : SUBSTRUCTURE To Summary Bill 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO.2.2 : UPPER STRUCTURE

Code Description Quantity Unit

UPPER STRUCTURE

Vibrated reinforced concrete K-350

A Column 470 m3

B Suspended beam 291 m3

C Suspended slab 668 m3

Bar reinforcement; deformed high tensile BJTD-40,


including bending, cutting to length and supplying and
installing all tying wire, accessories and consumable

D General reinforcing bars in columns; 22mm diameter 11,434 kg

E Ditto; 19mm diameter 49,036 kg

F Ditto; 13mm diameter 2,209 kg

G Stirrups in columns 10 mm diameter 23,120 kg

H Ditto; 8mm diameter 728 kg

I General reinforcing bars in suspended beams 42,524 kg

J General reinforcing bars in suspended slabs 86,786 kg


Formwork

K To sides of columns 4,732 m2

L To sides of supended beams 1,940 m2

M To soffit of supended slabs 5,563 m2

N To edges of suspended slab 100~200mm high 976 m

To Collection

COLLECTION

Page 6/Sub bill 2.2/7 Rp.


SUB BILL NO.2.2 : UPPER STRUCTURE To Summary Bill 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO.2.3 : ROOFING

Code Description Quantity Unit

ROOFING

Supply and install skylight consist of aluminium frame


powder coating finish and clear glass laminated
6mm+PVB+6mm as specified

A To Main Lobby 23 m2

Solid Timber Roof Clading type bengkirai as specified

B To Roof 456 m2

Supply and install 25 mm thick solid wood fascia


complete with 4 mm thick steel plate cover and all
necessary fixing accessoris

C
Solid wood fascia 500mm wide 28 m

SUB BILL NO.2.3 : ROOFING To Summary Bill 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO.2.4: STAIR FINISHES

Code Description Quantity Unit


STAIR FINISHES

STAIR 1 (Main BOH)

Fair face finish to expose concrete soffit

A Extra for fair face to soffits of staircases 29 m2

B Ditto; to soffit of landings

C Ditto; to open stringer maximum 350mm wide

Screed, cement and sand (1:3) mortar trowelled


smooth finish

D
Surfaces of landing; 30mm thick 15 m2

E
Surfaces of treads; 300mm wide x 30mm thick 39 m

F Surfaces of risers; 30mm thick not exceeding 200mm 39 m


high

Supply and install ceramic tiles 300 x300 ex : Roman


type Dpanama Perca, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified (F4B)

G To landing 15 m2

H To tread 300 mm wide 39 m

I To riser not exceeding 200 mm high 39 m

Prepare and apply one coat of primer and two finishing


coats of interior emulsion paint finish as specified

J To sloping soffits of stairs and landings 29 m2

K Paint to open stringer maximum 350 mm wide

Steel pipe balustrade including finishes and all


necessary fixing accessories as specified and
complete with paint finish as specified and as shown
on drawings

L Steel Pipe 8 m

To Collection

STAIR 1 (Main BOH) cont'd

Gypsumboard ceiling 9 mm thick plasterboard ex


Jayaboard, with galvanized suspension system 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C3)

A To ceiling 15 m2

STAIR 2 ( BOH)

Supply and install floor hardener poshed concrete ex:


MU, as specified (F5)

B To tread 300 mm wide 4 m

C To riser not exceeding 200 mm high 4 m

U Chanel 20 x 20
D To tread 300 mm wide 1 m

STAIR 3 ( Main Lobby)

Cement and sand (1:5) screed as specified

35 mm thick screed to floor to receive terazzo floor 825


E mm wide 60 m

Supply and install terazzo semi polished finishing as


specified (F1)

F To tread 825 mm wide 60 m

G To riser not exceeding 50 mm high 60 m

STAIR 4 ( Main Stair )

Fair face finish to expose concrete soffit

H Extra for fair face to soffits of staircases 198 m2

Cement and sand (1:5) screed as specified

I 35 mm thick screed to floor to receive ceramic 127 m2

To Collection

STAIR 4 ( Main Stair ) cont'd

Cement and sand (1:5) screed as specified

A To tread 300 mm wide 238 m

B To riser not exceeding 175 mm high 238 m

Supply and install homogenous tiles ex : Niro type , as


specified fixed with adhesive and grouted with white or
coloured tile grout as specified (F7B)

C To landing 51 m2

D To tread 300 mm wide 238 m

E To riser not exceeding 200 mm high 238 m

Supply and install polished concrete exposed


aggrerate ex Teknoklinz, 50 mm thickness, semi polish
finishing with natural colour as specified (F2)

F To landing 75 m2

Step nosing 5 x 10 mm created by machine

G To tread 300 mm wide 238 m

Solid Wood balustrade including finishes and all


necessary fixing accessories as specified and
complete with paint finish as specified and as shown
on drawings

H Solid Wood balustrade 28 m

Solid Wood hand railing

I Solid Wood hand railing 102 m

Solid wood cladding ex: Lante Kayu type ulin 180 x


4000 mm thickens 15 mm. Osmo coating finishing.
J Solid wood cladding 541 m2

To Collection

STAIR Function Room

Cement and sand (1:5) screed as specified

A To tread 400 mm wide 19 m

B To riser not exceeding 150 mm high 19 m

Supply and install polished concrete exposed


aggrerate ex Teknoklinz, 50 mm thickness, semi polish
finishing with natural colour as specified (F2)

C To tread 400 mm wide 19 m

D To riser not exceeding 150 mm high 19 m

To Collection

STAIR 1 (Bar and Lounge)

Supply and install steelstructure including finishing

A To landing 2 nos
B To tread 18 nos

Tempered Clear Glass 12 mm thick, 1100 mm high


balustrade including finishes and all necessary fixing
accessories as specified and complete as specified
and as shown on drawings

C Railing Glass 7 m1

STAIR 2 (Bar and Lounge)

Fair face finish to expose concrete soffit

D Extra for fair face to soffits of staircases 21 m2

Cement and sand (1:5) screed as specified

E 35 mm thick screed to floor to receive ceramic 9 m2

Cement and sand (1:5) screed as specified

F To tread 300 mm wide 61 m

G To riser not exceeding 175 mm high 61 m

Supply and install homogenous tiles ex : Niro type , as


specified fixed with adhesive and grouted with white or
coloured tile grout as specified (F7B)

H To landing 9 m2

I To tread 300 mm wide 61 m

J To riser not exceeding 200 mm high 61 m

Solid Wood balustrade including finishes and all


necessary fixing accessories as specified and
complete with paint finish as specified and as shown
on drawings

K Solid Wood balustrade 22 m

To Collection

STAIR 2 (Bar and Lounge) cont'd

Solid Wood hand railing

A Solid Wood hand railing 32 m

Solid wood cladding ex: Lante Kayu type ulin 180 x


4000 mm thickens 15 mm. Osmo coating finishing.

B Solid wood cladding 221 m2

Facility 4 (All Day Dining) Ramp 4

Supply and install floor hardener poshed concrete ex:


MU, as specified (F5)

C To ramp 59 m2

Solid brick walls with cement and sand (1:2), including


reinforced concrete practical columns and tie beams

D To walls, 100mm thick 30 m2

Plaster, cement and sand (1:3), mortar trowelled


smooth finish.

E To walls, 25 mm thick 60 m2
Prepare and apply one coat alkali resisting primer, one
coat water based emulsion sealer and two finishing
coats of exterior grade paint ex Lemkra as specified

F To exterior wall 60 m2

Solid Wood balustrade ex: Lantekayu including


finishes and all necessary fixing accessories as
specified and complete with paint finish as specified
and as shown on drawings

G 1020 mm high 47 m

H 300 mm high 47 m

To Collection

STAIR FINISHES

STAIR SPA

Fair face finish to expose concrete soffit

A Extra for fair face to soffits of staircases 11 m2

B Ditto; to soffit of landings

C Ditto; to open stringer maximum 350mm wide

Screed, cement and sand (1:3) mortar trowelled


smooth finish

D Surfaces of landing; 30mm thick 3 m2

E Surfaces of treads; 300mm wide x 30mm thick 26 m

Surfaces of risers; 30mm thick not exceeding 200mm 26 m


F high

Supply and install polished concrete exposed


aggrerate ex Teknoklinz, 50 mm thickness, semi polish
finishing with natural colour as specified (F2)

G To landing 3 m2

H To tread 300 mm wide 26 m

I To riser not exceeding 200 mm high 26 m

Prepare and apply one coat of primer and two finishing


coats of interior emulsion paint finish as specified

J To sloping soffits of stairs and landings 11 m2

K Paint to open stringer maximum 350 mm wide

Solid Wood balustrade ex: Lantekayu including


finishes and all necessary fixing accessories as
specified and complete with paint finish as specified
and as shown on drawings

L Solid Wood balustrade 10 m

M Solid Wood hand railing 10 m


To Collection

STAIR FINISHES

STAIR OUTDOOR DECK

Fair face finish to expose concrete soffit

A Extra for fair face to soffits of staircases 41 m2

B Ditto; to soffit of landings

C Ditto; to open stringer maximum 350mm wide

Screed, cement and sand (1:3) mortar trowelled


smooth finish

D Surfaces of landing; 30mm thick 23 m2

E Surfaces of treads; 300mm wide x 30mm thick 37 m

F Surfaces of risers; 30mm thick not exceeding 200mm 37 m


high

Supply and install polished concrete exposed


aggrerate ex Teknoklinz, 50 mm thickness, semi polish
finishing with natural colour as specified (F2)

G To landing 23 m2

H To tread 300 mm wide 37 m

I To riser not exceeding 200 mm high 37 m

Prepare and apply one coat of primer and two finishing


coats of interior emulsion paint finish as specified

J To sloping soffits of stairs and landings 41 m2

K Paint to open stringer maximum 350 mm wide

Solid Wood balustrade ex: Lantekayu including


finishes and all necessary fixing accessories as
specified and complete with paint finish as specified
and as shown on drawings

L Solid Wood balustrade 54 m1

To Collection

COLLECTION

Page 6/Sub bill 2.4/10 Rp.

Page 6/Sub bill 2.4/11 Rp.

Page 6/Sub bill 2.4/12 Rp.

Page 6/Sub bill 2.4/13 Rp.

Page 6/Sub bill 2.4/14 Rp.

Page 6/Sub bill 2.4/15 Rp.


Page 6/Sub bill 2.4/16 Rp.

Page 6/Sub bill 2.4/17 Rp.

SUB BILL NO.2.4: STAIR FINISHES To Summary Bill 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO.2.5 : EXTERNAL WALL & FINISHES

Code Description Quantity Unit

EXTERNAL WALL AND FINISHES

Facilities 1 (Lobby and BOH) East Elevation

Plaster, cement and sand (1:3), mortar trowelled


smooth finish.

A
To walls, 25 mm thick 616 m2

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of exterior grade paint ex Lemkra as specified

B Exterior paint at RTW 882 m2

C Exterior wall 364 m2

Screen solid Wood

D Exterior wall 85 m2

Metal Screen

E Exterior wall 87 m2

Solid wood railing including finishes and all necessary


fixing accessories as specified and complete with paint
finish as specified and as shown on drawings
F
Solid wood railing 34 m

Wood Panel Cover Coloumn

G
To Facade size 450 x 450 x 4900 mm high 13 nos

H
To Lobby size 570 x 870 x ..... mm high 2 nos

Facilities 1 (Lobby and BOH) South Elevation

Solid wood bengkirai ex Lantekayu 150 x 2100-2400


mm, thicknes 60 mm, osmo coating finishing

I
Wood Screen at external wall 380 m2

J
Wood Screen at stair (include to bill stair)

To Collection

Facilities 1 (Lobby and BOH) cont'd

Solid wood railing including finishes and all necessary


fixing accessories as specified and complete with paint
finish as specified and as shown on drawings

A
Solid wood railing 52 m

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of exterior grade paint ex Lemkra as specified

B Exterior wall 252 m2

Wood Panel Cover Coloumn

C
To Facade size 450 x 450 x 4200 mm high 15 nos

Solid wood railing including finishes and all necessary


fixing accessories as specified and complete with paint
finish as specified and as shown on drawings

D
Solid wood railing 85 m

Facilities 2 (Funtion Room)

Solid brick walls with cement and sand (1:2), including


reinforced concrete practical columns and tie beams

E
To walls, 100mm thick 135 m2

Solid wood cladding bengkirai/ jati doreng ex


Lantekayu 180 x 4000 x 15 mm thick osmo coating
finishing

F
To wall 349 m2
To Collection

Facilities 3 (Speciality Restaurant )

Solid brick walls with cement and sand (1:2), including


reinforced concrete practical columns and tie beams

A
To walls, 100mm thick 257 m2

Plaster, cement and sand (1:3), mortar trowelled


smooth finish.

B
To walls, 25 mm thick 257 m2

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of exterior grade paint ex Lemkra as specified

C
To exterior wall 134 m2

Solid wood railing including finishes and all necessary


fixing accessories as specified and complete with paint
finish as specified and as shown on drawings

D
Solid wood railing 31 m

Exposed wall plaster ex Mortar Utama

E
To wall 124 m2

To Collection

Facilities 4 (All Day Dining)

Stell plate color anthracite grey, thickness 2mm,


powder coat semi gloss finish random pattern

A To Facade 170 m2

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of exterior grade paint ex Lemkra as specified

B
To exterior wall 102 m2

Solid wood railing including finishes and all necessary


fixing accessories as specified and complete with paint
finish as specified and as shown on drawings

C
Solid wood railing 39 m
To Collection

Facilities 5 (Pool)

Solid wood cladding bengkirai ex Lantekayu 180 x


4000 x 15 mm thick osmo coating finishing

A
To wall 403 m2

Solid wood railing including finishes and all necessary


fixing accessories as specified and complete with paint
finish as specified and as shown on drawings

B
Solid wood railing 208 m

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of exterior grade paint ex Lemkra as specified

C
To exterior wall 347 m2

D
Cover Coloumn 4 nos
To Collection

COLLECTION

Page 6/Sub bill 2.5/19 Rp.

Page 6/Sub bill 2.5/20 Rp.

Page 6/Sub bill 2.5/21 Rp.

Page 6/Sub bill 2.5/22 Rp.

Page 6/Sub bill 2.5/23 Rp.

SUB BILL NO.2.5 : EXTERNAL WALL & FINISHES To Summary Bill 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO.2.6 : INTERNAL WALL
Code Description Quantity Unit

INTERNAL WALL

Facilities 1 (Lobby and BOH)

Solid brick walls with cement and sand (1:2), including


reinforced concrete practical columns and tie beams

A
To walls, 100mm thick 4,444 m2

B
To walls, 200mm thick 12 m2

Trasraam

C
To toilet wall 100 mm thick 586 m2

Glass partition

D
Glass partition 134 m2

Facilities 4 (All Day Dining)

Solid brick walls with cement and sand (1:2), including


reinforced concrete practical columns and tie beams

E
To walls, 100mm thick 311 m2

Tempered glass partition ex Asahimas type indoflot


clear float glass

F
Glass partition 145 m2

Facilities 5 (Pool)

Solid brick walls with cement and sand (1:2), including


reinforced concrete practical columns and tie beams

G
To walls, 100mm thick 156 m2

SUB BILL NO.2.6 : INTERNAL WALL To Summary Bill 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO.2.7 : DOORS & WINDOWS

Quantity Unit
Code Description

DOORS AND WINDOWS

Facility 1 (Lobby and BOH)

Metal Screen Window

A
Type W-01 size 16900 mm x 4600 mm high as 1 nos
specified
Fixed Glass Window

B
Type W-02 size 3070 x 4000 mm, clear tempered 1 nos
glass thickness 10 mm complete with all accesories as
specified

C
Type W-03 size 1710 x 3000 mm, clear tempered 1 nos
glass thickness 10 mm complete with all accesories as
specified

D
Type W-04 size 8430 x 3000 mm, clear tempered 1 nos
glass thickness 10 mm complete with all accesories as
specified

E Type W-05 size 1777.5 x 3000 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accesories as
specified

F Type W-07 size 5550 x 3000 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accesories as
specified

G Type W-09 size 5305 x 3000 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accessories
as specified

H Type W-13 size 3015 x 2500 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accessories
as specified

I Type W-14 size 1475 x 2500 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accessories
as specified

J Type W-15 size 1375 x 2500 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accessories
as specified

K Type W-16 size 5005 x 2500 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accessories
as specified

L Type W-17 size 2040 x 2500 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accessories
as specified

M Type W-18 size 1900 x 2500 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accessories
as specified

N Type W-19 size 2050 x 2500 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accessories
as specified

Fixed Glass Cashier Window

O Type W-08 size 1400 x 1900 mm, clear tempered 1 nos


glass thickness 10 mm complete with all accecories as
specified

P Type W-10 size 3765 x 1900 mm and 2130 x 1900 1 nos


mm, clear tempered glass thickness 10 mm complete
with all accecories as specified

Fixed Glass Bouvenlight

Q Type W-11 size 850 x 400 mm, clear tempered glass 1 nos
thickness 10 mm complete with all accessories as

Solid Wood Screen

R Type W-12 size 2950 x 2100 mm, solid wood 1 nos


bengkirai (osmo coating finish) complete with all
accessories as
Facility 1 (Lobby and BOH)

Timber doors

A Type D-01, Wood frame glass door (pivot), size 1360 x 15 nos
3000 mm as specified
B Type D-02, Hollow core door (swing), size 1000 x 3000 10 nos
mm as specified

C Type D-03, Engineered wood door (swing), size 800 x 1 nos


2500 mm as specified

D Type D-06, Engineered wood door (swing), size 800 x 3 nos


2500 mm as specified

E Type D-11, Engineered wood door (sliding), size 1000 2 nos


x 3000 mm as specified

F Type D-13, Timber Door (pivot), size 1000 x 3000 mm 4 nos


as specified

G Type D-14, Timber Door (swing), size 1350 x 2500 mm 1 nos


as specified

H Type D-17, Hollow core door (swing), size 900 x 2500 13 nos
mm as specified

I Type D-18, Hollow core door (swing), size 1600 x 2500 2 nos
mm as specified

J Type D-22, Timber Door (pivot), size 1050 x 2650 mm 2 nos


as specified

K Type D-23, Timber Door (pivot), size 950 x 2650 mm 1 nos


as specified

L Type D-24, Timber Door (pivot), size 800 x 2800 mm 22 nos


as specified

M Type D-25, Timber Core Door (swing), size 800 x 2500 8 nos
mm as specified

To Collection Rp.

Facility 1 (Lobby and BOH) (Cont'd)

A Type D-26, Timber Core Door (swing), size 950 x 2500 2 nos
mm as specified

B Type D-27, Timber Door (pivot), size 1000 x 2650 mm 4 nos


as specified

C Type D-28, Timber Door (pivot), size 1100 x 2650 mm 1 nos


as specified

Steel Door

D Type D-04, Steel Door (swing) size 1600 x 2500 mm 7 nos


as specified

E Type D-05, Steel Door (swing) size 2000 x 2500 mm 2 nos


as specified

F Type D-09, Steel Door (swing) size 1000 x 2450 mm 4 nos


as specified

G Type D-10, Steel Door (sliding) size 3140 x 2500 mm 1 nos


as specified

H Type D-12, Steel Door (pivot) size 2000 x 2500 mm as 3 nos


specified

I Type D-15, Steel Door (pivot) size 1600 x 2500 mm as 3 nos


specified

J Type D-16, Steel Door (swing) size 1100 x 3000 mm 1 nos


as specified
K Type D-19, Steel Door (swing) size 1000 x 2500 mm 11 nos
as specified

L Type D-20, Steel Door (swing) size 1194 x 2500 mm 2 nos


as specified

M Type D-21, Steel Door (pivot) size 1100 x 2200 mm as 1 nos


specified

To Collection Rp.

Facility 1 (Lobby and BOH) (Cont'd)

Folding Gate

A Type D-07, Folding gate size 2420 x 2500 mm as 1 nos


specified

B Type D-08 Folding gate size 3450 x 2500 mm as 1 nos


specified

0.00 To Collection Rp.


Facility 2 (Function Room)

Aluminium Door

A Type D-01, Aluminium door size 1000 x 2500 mm as 4 nos


specified

Timber Door

B Type D-02, timber door size 2000 x 2500 mm as 2 nos


specified

Screen

C
Type S-01, Screen size 19310 x 2500 mm as specified 1 nos

Facility 3 (Bar and Lounge)

Timber Door

D Type D-01,Hollow Timber Door (swing) size 900 x 13 nos


2500 mm as specified

E Type D-06, timber door (pivot) size 800 x 2800 mm as 7 nos


specified

F Type D-07, timber door (pivot) size 950 x 2650 mm as 3 nos


specified

Aluminium Door

G Type D-02, Aluminium frame glass door (swing) size 1 nos


4250 x 3000 mm as specified

H Type D-03, Aluminium frame glass door (swing) size 1 nos


15300 x 6700 mm as specified

I Type D-04, Aluminium frame glass door (swing) size 2 nos


2000 x 2700 mm as specified

Steel Door

J Type D-05, steel door (swing) size 1000 x 2450 mm as 1 nos


specified

To Collection Rp.

Facility 3 (Bar and Lounge ) (Cont'd)

Aluminium Window

A Type W-01, Aluminium frame tempered clear glass 2 nos


window (swing) size 14500 x 3430 mm as specified

B Type W-02, Aluminium frame tempered clear glass 2 nos


window (swing) size 11600 x 3270 mm as specified

Facility 4 (All Day Dining)

Timber Door

C Type D-01, Engineered Wood Door (Swing), size 800 x 1 nos


2500 mm, as specified

D Type D-02,Hollow Timber Door (Swing), size 900 x 5 nos


2500 mm, as specified

E Type D-05,Timber Door (Swing), size 2000 x 3000 1 nos


mm, as specified
F Type D-07, Solid Wood Glass Door (Folding), size 4 nos
3292 x 4250 mm as specified

G Type D-08, Solid Wood Glass Door (Folding), size 2 nos


3252 x 4250 mm as specified

H Type D-09, Solid Wood Glass Door (Folding), size 3 nos


3692 x 4250 mm as specified

I Type D-10, Solid Wood Glass Door (Folding), size 2 nos


3652 x 4250 mm as specified

J Type D-11,Hollow Timber Core Door (Double), size 2 nos


1700 x 2500 mm, as specified

K Type D-12,Engineered Timber Door (Pocket), size 702 1 nos


x 2500 mm, as specified

To Collection Rp.

Facility 4 ( All Day Dining ) (Cont'd)

Steel Door

A Type D-03, Steel Door (Swing), size 1000 x 2500 mm, 2 nos
as specified

B Type D-04, Steel Door (Swing), size 1000 x 2450 mm, 1 nos
as specified

C Type D-06, Steel Door (pivot), size 1600 x 2500 mm, 1 nos
as specified

D Type D-13, Steel Door (pivot), size 1600 x 2500 mm, 3 nos
as specified

Timber Window

E Type W-01, Slide and fold glass window with solid 4 nos
timber frame, size 3292 x 2600 mm, as specified

F Type W-02, Slide and fold glass window with solid 2 nos
timber frame, size 3252 x 2600 mm, as specified

G Type W-03, Slide and fold glass window with solid 3 nos
timber frame, size 3692 x 2600 mm, as specified

H Type W-04, Slide and fold glass window with solid 2 nos
timber frame, size 3652 x 2600 mm, as specified

Glass Window

I Type D-05, Fixed tempered clear glass window, size 4 nos


3292 x 3300 mm, as specified

J Type D-06, Fixed tempered clear glass window, size 2 nos


3252 x 3300 mm, as specified

K Type D-07, Fixed tempered clear glass window, size 3 nos


3692 x 3300 mm, as specified

L Type D-08, Fixed tempered clear glass window, size 2 nos


3652 x 3300 mm, as specified
To Collection Rp.

Facility 5 (Pool & Spa)

Steel Door

A Type D-01, Steel door (swing), size 1000 x 2450, as 3 nos


specified

B Type D-02, Steel door (pivot), size 1550 x 2400 as 2 nos


specified

C Type D-03, solid core door (swing), size 1000 x 2500 3 nos
as specified

D Type D-04, solid core sliding door (pocket), size 1000 x 2 nos
2450 as specified

E Type D-05, solid core door (swing), size 1000 x 2450 1 nos
as specified

Timber Door

F Type D-06, sliding louvers door (pocket), size 1000 x 1 nos


2450 mm as specified

G Type D-07, sliding louvers door (pocket), size 800 x 2 nos


2450 mm as specified

To Collection Rp.

COLLECTION

Page 6/Sub bill 2.7/26 Rp.

Page 6/Sub bill 2.7/27 Rp.

Page 6/Sub bill 2.7/28 Rp.

Page 6/Sub bill 2.7/29 Rp.

Page 6/Sub bill 2.7/30 Rp.


Page 6/Sub bill 2.7/31 Rp.

Page 6/Sub bill 2.7/32 Rp.

SUB BILL NO.2.7 : DOORS & WINDOWS Summary Bill No. 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO.2.8 : WALL FINISHES

Code Description Quantity Unit

WALL FINISHES

Facility 1 (Lobby and BOH)

Plaster, cement and sand (1:5), mortar trowelled


smooth finish.

A
To walls and columns, 25 mm thick 7,711 m2

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

B To bathroom and toilet walls 172 m2

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of exterior grade paint ex Lemkra as specified

C
Paint finishes 550 m2

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of interior grade paint ex Propan as specified
D
Paint finishes 4,344 m2

Supply and install andhesit stone finish ex:MM Galeri


size 300 x 600 x 20 mm thick, honed, complete with
mortar bed and grout

E
Stone finishes 427 m2

Fire rated gysum interior, ex USG Boral firestop 16


mm, twin stud fire rated ex JayaBMS widht 92 mm,
thickness 0,5 BMT

F
To wall 392 m2

Supply and install ceramic tiles 300 x300 ex : Roman


type Serenity Bianca, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified
817 m2
G
Ceramic tile finishes

To Collection

Facility 1 (Lobby and BOH) (Cont'd)

Solid wood bengkirai ex Lantekayu 150 x 2100-2400


mm, thicknes 60 mm, osmo coating finishing.

A
Timber finishes 298 m2

Expose wall plaster ex: mortar utama type MU-70

B
To wall expose 65 m2

Supply and install paras kerobokan natural stone 20


mm thick, honed, complete with mortar bed and grout
185 m2
C
To wall

Wood Panel Cover Coloumn

D
To Facade size 450 x 450 x 4900 mm high 21 nos

Supply and install ceramic tiles 300 x 600 ex : Roman


type Dpanama Perca, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified

E
Ceramic tile finishes to toilet 1,583 m2

Supply and install ceramic tiles 80 x 600 ex : Roman


type Dportland Grey, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified

F
Skirting to wall 215 m1

Supply and install ceramic tiles 80 x 400ex : Roman


type Dportland Grey, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified

G
Skirting to wall 70 m1

Facilities 2 (Funtion Room)

Solid wood cladding bengkirai ex Lantekayu 180 x


4000 x 15 mm thick osmo coating finishing

H
To wall 203 m2
To Collection

Facilities 2 (Funtion Room) (Cont'd)

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of exterior grade paint ex Lemkra as specified

A
Paint finishes 146 m2

Facilities 3 (Speciality Restaurant)

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of interior grade paint ex Propan as specified

B
Paint finishes 188 m2

Wood Panel Cover Coloumn

C
To Facade size 450 x 450 x 6700 mm high 14 nos

Tempered Clear Glass 12 mm thick, 1100 mm high


balustrade including finishes and all necessary fixing
accessories as specified and complete as specified
and as shown on drawings

D Railing Glass 14 m1

To Collection

Facilities 4 (All Day Dining)

Wood Panel Cover Coloumn solid wood ex Lantekayu


type bengkirai

A To coloumn at B1 Floor 20 nos

B To coloumn at B2 Floor 20 nos

C To coloumn at B3 Floor 20 nos


Prepare and apply one coat alkali resisting primer, one
coat water based emulsion sealer and two finishing
coats of interior grade paint ex Propan as specified

D
Paint finishes 192 m2

Metal Stell plate color anthracite grey, thickness 2mm,


powder coat semi gloss finish random pattern

E To wall 90 m2

Supply and install paras kerobokan natural stone 20


mm thick, honed, complete with mortar bed and grout
134 m2
G
To wall

Supply and install marble stone finish ex: MM Galeri


size 200 x 600 x 20 mm thick,polished , complete with
mortar bed and grout

H
To wall 203 m2

0.00
To Collection

Facilities 5 (Pool)

Plaster, cement and sand (1:5), mortar trowelled


smooth finish.

A
To walls and columns, 25 mm thick 120 m2

Prepare and apply one coat alkali resisting primer, one


coat water based emulsion sealer and two finishing
coats of interior grade paint ex Propan as specified

B
Paint finishes 120 m2

Supply and install ceramic tiles 300 x 600 ex : Roman


type Dpanama Perca, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified

C Ceramic tile finishes to toilet 43 m2

Expose wall plaster with insulation

D To Wall 237 m2
To Collection

Public Toilet Lobby

Screen wood

A
To wall 18 m2

Supply and install andhesit stone finish ex: MM Galeri


size 180 x 300 x 20 mm thick, honed, complete with
mortar bed and grout

B
To wall 45 m2

Supply and install andhesit stone finish ex: MM Galeri


size 300 x 600 x 20 mm thick, honed, complete with
mortar bed and grout

C
To wall 40 m2

Supply and install marble stone finish ex: MM Galeri


size 200 x 600 x 20 mm thick,polished , complete with
mortar bed and grout

D
To wall 147 m2

Public Toilet at Sunken Plaza

Supply and install ceramic tiles 300 x 600 ex : Roman


type Dpanama Perca, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified
E
Ceramic tile finishes to toilet 15 m2

Supply and install andhesit stone finish ex: MM Galeri


size 180 x 300 x 20 mm thick, honed, complete with
mortar bed and grout

F
To wall 4 m2

Supply and install andhesit stone finish ex: MM Galeri


size 300 x 600 x 20 mm thick, honed, complete with
mortar bed and grout

G
To wall 85 m2

Supply and install marble stone finish ex: MM Galeri


size 200 x 600 x 20 mm thick,polished , complete with
mortar bed and grout

D
To wall 194 m2
To Collection

Public Toilet Bar and Lounge

Supply and install andhesit stone finish ex: MM Galeri


size 180 x 300 x 20 mm thick, honed, complete with
mortar bed and grout

A
To wall 46 m2

Supply and install marble stone finish ex: MM Galeri


size 200 x 600 x 20 mm thick,polished , complete with
mortar bed and grout

B
To wall 167 m2

To Collection

COLLECTION

Page 6/Sub bill 2.8/34 Rp.

Page 6/Sub bill 2.8/35 Rp.


Page 6/Sub bill 2.8/36 Rp.

Page 6/Sub bill 2.8/37 Rp.

Page 6/Sub bill 2.8/38 Rp.

Page 6/Sub bill 2.8/39 Rp.

Page 6/Sub bill 2.8/40 Rp.

SUB BILL NO.2.8 : WALL FINISHES Summary Bill No. 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO.2.9 : FLOOR FINISHES

Quantity Unit
Code Description

FLOOR FINISHES

Facility 1 (Lobby and BOH)

Cement and sand (1:5) screed as specified

A 35 mm thick screed to floor to receive terazzo floor 527 m2

B 35 mm thick screed to floor to receive ceramic floor 944 m2

C 35 mm thick screed to floor to receive andesite floor 61 m2

D 35 mm thick screed to floor to receive pebble stone 120 m2

E 10 mm thick screed to protection waterproofing at toilet 316 m2


Supply and install approved CL waterproofing system
in accordance with the manufactures instructions as
specified

F To toilet floor 316 m2

Supply and install terazzo semi polished finishing as


specified (F1)

G To Main lobby, public toilet, ramp public area and ramp 527 m2
sitting area

Supply and install polished concrete exposed


aggrerate ex Teknoklinz, 50 mm thickness, semi polish
finishing with natural colour as specified (F2)

H To ramp and sunken plaza, corridor and toilet 505 m2

Supply and install solid wood decking ex: Lante Kayu,


Type Bangkirai 90x 3000 mm, 20 mm thick and Osmo
Coating Finishing as specified (F3)

I To retail and lobby lounge 339 m2

Supply and install solid wood decking ex: Lante Kayu,


Type Ulin 180 x 4000 mm, 15 mm thick and Osmo
Coating Finishing as specified (F3B)

J
To roof floor 397 m2

To Collection

Facility 1 (Lobby and BOH) (Cont'd)

Supply and install ceramic tiles 600 x 600 ex : Roman


type Dportland Grey, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified (F4A)

A
To room 471 m2

Supply and install ceramic tiles 300 x300 ex : Roman


type Dpanama Perca, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified (F4B)

B
To FCC Room 4 m2

Supply and install ceramic tiles 200 x 200 ex : Roman


type Dpanama Perca, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified (F4C)

C
To toilet gas room 2 m2

Supply and install ceramic tiles 300 x 300 ex : Roman


type Serenity Bianca, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified (F4D)

D
To room 109 m2

Supply and install ceramic tiles 600 x 600 ex : Roman


type Serenity Bianca, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified (F4E)

E
To cafetaria 102 m2

Supply and install ceramic tiles 400 x 400 ex : Roman


type Dportland Grey, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified (F4F)
F
To room 187 m2

To Collection

Facility 1 (Lobby and BOH) (Cont'd)

Supply and install ceramic tiles 300 x 300 ex : Roman


type Dagusta Black, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified (F4G)

A
To male and female locker toilet 70 m2

Supply and install floor hardener poshed concrete ex:


flowcrete, deckshiled ed papide, textured finishing,
warm grey colour as specified (F5A)

B
To corridor and roof floor 1,962 m2

Supply and install floor hardener poshed concrete ex:


flowcrete, flowresh MF, 3mm thickness, matt finishing,
light grey colour as specified (F5B)

C
To corridor and room 907 m2

Epoxy, ex Flowcrete, flowshield SL 100, thickness


1mm, gloss finishing, lighr grey colour (F5C)

D
To genset, panel, and trafo room 173 m2

E
To roof floor 189 m2

Supply and install floor hardener poshed concrete ex:


flowcrete, flowresh SR, 4mm thickness, satin finishing,
light grey colour as specified (F5D)

F
To Main kitchen 242 m2

Soill and grass refer to lansdscpe (F8)

Supply and install andhesit stone floor finish ex: MM


Galeri, random size100 x 600mm, 200 x 600 mm, 10
mm thick, honed and flamed fin random, complete with
mortar bed and grout (F9A)

G
To floor 61 m2

Pebble stone (F11)

H
To dry garden and public toliet 120 m2

To Collection

Facility 1 (Lobby and BOH) (Cont'd)

Supply and install andhesit stone floor finish ex: MM


Galeri, random size 600 x 600mm, 200 x 600 mm, 10
mm thick, honed and flamed fin random, complete with
mortar bed and grout (F9B)

A
To public toilet lobby 8 m2

Pond
Supply and install approved CL waterproofing system
in accordance with the manufactures instructions as
specified

B
To floor of Pond 238 m2

C
To wall of Pond 62 m2

D To capping of Pond 178 m

Cement and sand (1:5) screed as specified

E 10 mm thick screed to protection waterproofing 318 m2

F 35 mm thick screed to floor of pond to receive stone 238 m2


finish

G 10 mm thick screed to wall of pond to receive stone 62 m2


finish

H 10 mm thick screed to capping of pond receive stone 178 m


finish

Supply and install andhesit stone floor finish ex: Alam


Inti size …….mm thick, honed, complete with mortar
bed and grout

I
To floor of pond 238 m2

J
To wall of pond 62 m2

K
To Capping of Pool 300 wide 178 m

To Collection

Facilities 2 (Function Room)

Soill and grass refer to lansdscpe (F8)

A
To roof garden 288 m2

Supply and install polished concrete exposed


aggrerate ex Teknoklinz, 50 mm thickness, semi polish
finishing with natural colour as specified (F2)

B
To floor 37 m2

Supply and install solid wood decking ex: Lante Kayu,


Type Bangkirai 90x 3000 mm, 20 mm thick and Osmo
Coating Finishing as specified (F3)

C To floor 337 m2
To Collection

Facilities 3 (Bar and Lounge)

Supply and install polished concrete exposed


aggrerate ex Teknoklinz, 50 mm thickness, semi polish
finishing with natural colour as specified (F2)

A
To floor 382 m2

Supply and install solid wood decking ex: Lante Kayu,


Type Bangkirai 90x 3000 mm, 20 mm thick and Osmo
Coating Finishing as specified (F3)

B To deck 697 m2

Supply and install floor hardener poshed concrete ex:


flowcrete, flowresh MF, 3mm thickness, matt finishing,
light grey colour as specified (F5B)

C To machine room 23 m2

Soill and grass refer to lansdscpe (F8)

D
To garden 48 m2

Shallow Pond

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

E
To floor of Pond 227 m2

F
To wall of Pond 65 m2

G To capping of Pond 237 m

Cement and sand (1:5) screed as specified

H 10 mm thick screed to protection waterproofing 315 m2

I 35 mm thick screed to floor of pond to receive stone fini 227 m2

To Collection
Facilities 3 (Bar and Lounge) (Cont'd)

A 10 mm thick screed to wall of pond to receive stone fini 65 m2

B 10 mm thick screed to capping of pond to receive stone 237 m

Supply and install andhesit stone floor finish ex: Alam


Inti size …….mm thick, honed, complete with mortar
bed and grout

C
To floor of pond 227 m2

D
To wall of pond 65 m2

E
To Capping of Pool 300 wide 227 m

Swimming Pool

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

F
To floor of pool 170 m2

G
To wall of pool 97 m2

H To capping of pool 44 m

I To step of stair 28 m

J To riser of stair 28 m

Cement and sand (1:5) screed as specified

K 10 mm thick screed to protection waterproofing 275 m2

L 35 mm thick screed to floor of pool to receive stone finis 170 m2

M 10 mm thick screed to wall of pool to receive stone finis 97 m2

N 10 mm thick screed to capping of pool to receive stone 44 m

O 10 mm thick screed to step 28 m

P 10 mm thick screed to riser 28 m

To Collection

Facilities 3 (Bar and Lounge) (Cont'd)

Swimming Pool

Supply and install andhesit stone floor finish ex: Alam


Inti size …….mm thick, honed, complete with mortar
bed and grout

A
To floor of pool 170 m2

B
To wall of pool 97 m2

C To capping of pool 44 m

D To step of stair 28 m

E To riser of stair 28 m
To Collection

Facilities 4 (All Day Dining)

Cement and sand (1:5) screed as specified

A 35 mm thick screed to floor to receive terazzo floor 20 m2

B 35 mm thick screed to floor to receive ceramic floor 11 m2

Supply and install terazzo semi polished finishing as


specified (F1)

C To floor 20 m2

Supply and install polished concrete exposed


aggrerate ex Teknoklinz, 50 mm thickness, semi polish
finishing with natural colour as specified (F2)

D To floor of corridor and room 755 m2

Supply and install solid wood decking ex: Lante Kayu,


Type Bangkirai 90x 3000 mm, 20 mm thick and Osmo
Coating Finishing as specified (F3)

E To All Day Dining Restaurant 398 m2

Supply and install ceramic tiles 400 x 400 ex : Roman


type Dportland Grey, as specified fixed with adhesive
and grouted with white or coloured tile grout as
specified (F4F)

F To storage floor 11 m2

Supply and install floor hardener poshed concrete ex:


flowcrete, flowresh MF, 3mm thickness, matt finishing,
light grey colour as specified (F5B)

G To pumproom and outdoor unit 30 m2

Soill and grass refer to lansdscpe (F8)


H To roof garden 579 m2

Supply and install vinyl parquet ex: Lante Kayu, Alur


Locking species : noche 5 x 190 x 1210 mm as
specified (F13)

I
To gym, kids club and teens club 239 m2

To Collection Rp.

FACILITIES 5 MAIN POOL

Main Pool

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

A To pool deck and outdoor deck 140 m2

B
To floor of Pool and gutter 294 m2

C
To wall of Pool and gutter 209 m2

D To gutter overflow 88 m

Cement and sand (1:5) screed as specified

E 10 mm thick screed to protection waterproofing at deck 140 m2

F 10 mm thick screed to floor of pool and gutter 294 m2

G 10 mm thick screed to wall of pool and gutter 209 m2

H 10 mm thick screed to gutter overflow 88 m

Supply and install solid wood decking ex: Lante Kayu,


Type Bangkirai 90x 3000 mm, 20 mm thick and Osmo
Coating Finishing as specified.

I
To pool deck 140 m

Supply and install mosaic tiles 75 x 75 ex : Wisma


Sehati, as specified fixed with adhesive and grouted
with white or coloured tile grout as specified.

J
To Floor of Pool and gutter 294 m2

K
To Wall of Pool and gutter 209 m2

Supply and install andhesit stone floor finish ex: Alam


Inti size …….mm thick, honed, complete with mortar
bed and grout

L
To gutter overflow 300 wide 88 m

M
To edging of planter box 13 m

To Collection Rp.

FACILITIES 5 (Cont'd)

Kids Pool

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified
A To pool deck include Main Pool

B
To floor of Pool 49 m2

C
To wall of Pool 19 m2

D To capping of Pool 7 m

Cement and sand (1:5) screed as specified

E 10 mm thick screed to protection waterproofing include


Main pool

F 35 mm thick screed to floor of pool 49 m2

G 10 mm thick screed to wall of pool 19 m2

H 10 mm thick screed to capping of pool 7 m

Supply and install polished concrete exposed


aggrerate ex: Teknoklinz, 50 mm thick, semi polish
finishing natural colour

I
To floor 7 m2

Supply and install mosaic tiles 75 x 75 ex : Wisma


Sehati, as specified fixed with adhesive and grouted
with white or coloured tile grout as specified.

J
To Pool floor 49 m2

K
To Pool wall 19 m2

Supply and install andhesit stone floor finish ex: Alam


Inti size …….mm thick, honed, complete with mortar
bed and grout

L
To pool caping 500 wide 7 m

M
To edging of planter box 14 m

To Collection Rp.

FACILITIES (Cont'd)

Shallow Pond Area Pool

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

A
To floor of Pond 25 m2

B
To wall of Pond 7 m2

C To capping of Pond 23 m

Cement and sand (1:5) screed as specified

D 10 mm thick screed to protection waterproofing 37 m2

E 35 mm thick screed to floor of pond to receive stone fini 25 m2

F 10 mm thick screed to wall of pond to receive stone fini 7 m2

G 10 mm thick screed to capping of pond receive stone fin 22 m

Supply and install andhesit stone floor finish ex: Alam


Inti size …….mm thick, honed, complete with mortar
bed and grout

H
To floor of pond 25 m2
I
To wall of pond 7 m2

J
To Capping of Pond 300 wide 22 m

Drop Off area

K
Drop Area refer to landscape drawing

L
Watercascade refer to landscape drawing

M
Ramp refer to landscape drawing

N
Pedestrian Way refer to landscape drawing

To Collection Rp.

COLLECTION

Page 6/Sub bill 2.9/42 Rp.

Page 6/Sub bill 2.9/43 Rp.

Page 6/Sub bill 2.9/44 Rp.

Page 6/Sub bill 2.9/45 Rp.

Page 6/Sub bill 2.9/46 Rp.

Page 6/Sub bill 2.9/47 Rp.

Page 6/Sub bill 2.9/48 Rp.

Page 6/Sub bill 2.9/49 Rp.

Page 6/Sub bill 2.9/50 Rp.

Page 6/Sub bill 2.9/51 Rp.

Page 6/Sub bill 2.9/52 Rp.

Page 6/Sub bill 2.9/53 Rp.


SUB BILL NO.2.9 : FLOOR FINISHES To Summary Bill 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO.2.10 : CEILING FINISHES

Code Description Quantity Unit

CEILING FINISHES

Facility 1 (Lobby and BOH)

Solid wood ceiling, ex: Lantekayu, type Bangkirai size


20 x 90 x 4000 mm osmo coating finishing, Natural
Closed Pore, include galvanized metal suspension
system, joints, trim with all necessary fixing
accessories as specified on drawing and specification
(C1)

A
To Main Lobby 427 m2

Solid wood ceiling, ex: Lantekayu, type Ulin size 15 x


180 x 4000 mm osmo coating finishing, Natural Closed
Pore, include galvanized metal suspension system,
joints, trim with all necessary fixing accessories as
specified on drawing and specification (C1A)

B
To lobby Lounge 201 m2

Gypsum board water resistent ceiling 9,5 mm thick


plasterboard ex USG Boral, 144-3 Barston Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2)

C To corridor and room 601 m2

Gypsum moisture resist ceiling 9 mm thick


plasterboard ex USG Boral, Off white Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2A)

D To corridor and room 577 m2

Gypsum moisture resist ceiling 13 mm thick


plasterboard ex USG Boral, 144-3 Barston Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2C)

E To toilet and room 50 m2

To Collection Rp.

Facility 1 (Lobby and BOH) (Cont'd)

Gypsum moisture resist ceiling 13 mm thick


plasterboard ex USG Boral, Off White Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2D)

A To room 245 m2
Gypsumboard ceiling 9 mm thick plasterboard ex
Jayaboard, with galvanized metal furing system 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2E)

B To room 454 m2

Concrete panel ex USG Boral, Durock Metal Furring


Frame ex JayaBMS (C3)

C To corridor and room 264 m2

Mineral fiber acoustic ceiling ex USG Boral pin per, 60


x 120 mm thickness, with metal frame system ex USG
Boral, Donn Dx Frame (C4A)

D To room 407 m2

Exposed Slab (C5)

E To room 247 m2

Metal ceiling Plate ex USG Boral, haiglangland lay in


tile with metal frame ex USG Boral, Donn Dx Frame
(C7)

F To room 251 m2

Paint Finishes

G To gypsumboard ceiling 1,926 m2

To Collection Rp.

Facilities 2 (Function Room)

Gypsum board water resistent ceiling 9,5 mm thick


plasterboard ex USG Boral, 144-3 Barston Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2)

A To Corridor 37 m2

Mineral fiber acoustic ceiling ex USG Boral pin per, 60


x 120 mm thickness, with metal frame system ex USG
Boral, Donn Dx Frame (C4A)

B To function room and pre function room 337 m2

Paint Finishes

C To gypsumboard ceiling 37 m2
To Collection Rp.

Facilities 3 (Bar and Lounge)

Gypsum board water resistent ceiling 9,5 mm thick


plasterboard ex USG Boral, 144-3 Barston Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2)

A To corridor 97 m2

Gypsum moisture resist ceiling 9 mm thick


plasterboard ex USG Boral, 144-3 Barston Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2B)

B To corridor and room 284 m2

Gypsum moisture resist ceiling 13 mm thick


plasterboard ex USG Boral, 144-3 Barston Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2C)

C To speciality restaurant 324 m2

Exposed Slab (C5)

D To machine room 23 m2

Paint Finishes

E To gypsumboard ceiling 704 m2

To Collection Rp.
Facilities 4 (All Day Dining)

Gypsum moisture resist ceiling 9 mm thick


plasterboard ex USG Boral, 144-3 Barston Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2B)

A To Room 476 m2

Gypsumboard ceiling 9 mm thick plasterboard ex


Jayaboard, with galvanized metal furing system 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2E)

B To storage room 11 m2

Gypsumboard ceiling 9 mm thick plasterboard ex


Jayaboard, with galvanized metal furing system 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2E)

C To gym, kids club and teens club 239 m2

Exposed Slab (C5)

D To pump room and outdoor unit 31 m2

Paint Finishes

E To gypsumboard ceiling 727 m2

To Collection Rp.

Facilities 5 (Main Pool)

Gypsum board water resistent ceiling 9,5 mm thick


plasterboard ex USG Boral, 144-3 Barston Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2)

A
To corridor 14 m2

Gypsum moisture resist ceiling 9 mm thick


plasterboard ex USG Boral, 144-3 Barston Colour with
galvanized metal furing system ex JayaBMS, 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2B)

B
To corridor 28 m2

Gypsumboard ceiling 9 mm thick plasterboard ex


Jayaboard, with galvanized metal furing system 15 mm
width shadow line, including joints, trim and all fixing
accessories as specified (C2E)
C
To toilet 50 m2

Exposed Slab (C5)

D To pump room and outdoor unit 105 m2

Paint Finishes

E To gypsumboard ceiling 92 m2

To Collection Rp.

COLLECTION

Page 6/Sub bill 2.10/55 Rp.

Page 6/Sub bill 2.10/56 Rp.

Page 6/Sub bill 2.10/57 Rp.

Page 6/Sub bill 2.10/58 Rp.

Page 6/Sub bill 2.10/59 Rp.

Page 6/Sub bill 2.10/60 Rp.


SUB BILL NO.2.10 : CEILING FINISHES To Summary Bill 2 Rp.

BILL NO. 2: MAIN BUILDING


SUB BILL NO. 2.11 : PLUMBING INSTALLATION

Code Description Quantity Unit

BASEMENT 5

COLD WATER SYSTEM

DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 20 mm diameter pipework (Provisional Quantty) 20 m

Valve and ancillaries including joints to pipeworks

B 20 mm diameter gate valve 1 no


COLD WATER SYSTEM To Collection Rp.

BASEMENT 5

WASTE & DRAIN WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Sewage pump (SWP-7A/B), summersible open 1 set


impeller type, capacity 400 lpm, head 20 m, power 7.5
Kw/380/3/50Hz, parallel alternate, non-clog, complete
with control panel, valve,floating switches and
accesories (2 units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

A 100 mm diameter, pipework 36 m


B 80 mm diameter, ditto 24 m

Extra over pipework

C Bend 90 degree, 100 mm diameter 2 no

D Bend 45 degree, 100 mm diameter 4 no

E Tee diameter 100 x 100 x 100 mm 5 no

F Tee diameter 80 x 80 x 65 mm 5 no

WASTE & DRAIN WATER SYSTEM To Collection Rp.

BASEMENT 5

ASSOCIATED ELECTRICAL WORK

A Supply and install cable complete with termination, 2 no


splices, tags, conduit and all necessary supporting
accessories
ASSOCIATED ELECTRICAL WORK To Collection Rp.

BASEMENT 5

COLLECTION

COLD WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

ASSOCIATED ELECTRICAL WORK Rp.


BASEMENT 5 To Collection Rp.

BASEMENT 4

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 65 mm diameter pipework 4 m

B 40 mm diameter ditto 65 m

C 25 mm diameter ditto 14 m

D 20 mm diameter ditto 10 m

E 15 mm diameter ditto 2 m

Extra over pipework

F Tee diameter 65 x 65 x 50 mm 1 no

G Valve and ancillaries including joints to pipeworks

H 25 mm diameter gate valve (provisional quantity) 2 no

I 20 mm diameter ditto 2 no

J 15 mm diameter ditto 1 no

COLD WATER SYSTEM To Collection Rp.


BASEMENT 4

BASEMENT 4

HOT WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 25 mm diameter pipework 4 m

B 20 mm diameter ditto 12 m

C 15 mm diameter ditto 2 m

HOT WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

A 100 mm diameter, pipework 24 m

B 80 mm diameter, ditto 26 m

C 65 mm diameter, ditto 7 m

Extra over pipework

D Bend 45 degree, 100 mm diameter 2 no

E Bend 45 degree, 80 mm diameter 3 no

F Bend 45 degree, 65 mm diameter 4 no

G Tee diameter 100 x 100 x 100 mm 2 no

H Tee diameter 80 x 80 x 65 mm 5 no
WASTE & DRAIN WATER SYSTEM To Collection Rp.

BASEMENT 4

RAIN WATER SYSTEM

Supply and install Roof drain, fixed in position


complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

100 mm diameter roof drain 2 no

RAIN WATER SYSTEM To Collection Rp.

BASEMENT 4

COLLECTION
COLD WATER SYSTEM Rp.

HOT WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

RAIN WATER SYSTEM Rp.

BASEMENT 4 To Collection Rp.

BASEMENT 3A

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 50 mm diameter Header, with ± 7 m length 1 no

B 50 mm diameter pipework 58 m
C 40 mm diameter ditto 10 m

D 20 mm diameter ditto 10 m

E 15 mm diameter ditto 1 m
Valve and ancillaries including joints to pipeworks

F 40 mm diameter powered control valve 1 no

G 50 mm diameter gate valve 1 no

H 40 mm diameter ditto 2 no

I 20 mm diameter ditto 1 no

J 40 mm diameter check valve 1 no

K 40 mm diameter water mur 1 no

L 50 mm diameter floating valve 1 no

M 15 mm diameter Faucet 1 no

COLD WATER SYSTEM To Collection Rp.

BASEMENT 3A

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

A 100 mm diameter pipework 58 m

Extra over pipework

B Bend 90 degree, 100 mm diameter 2 no

C Tee diameter 100 x 100 x 100 mm 5 no

D 100 mm diameter roof drain 6 no


RAIN WATER SYSTEM To Collection Rp.

BASEMENT 3A

COLLECTION

COLD WATER SYSTEM Rp.

RAIN WATER SYSTEM Rp.

BASEMENT 3A To Collection Rp.


BASEMENT 3

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 65 mm diameter pipework 16 m

B 40 mm diameter ditto 14 m

C 32 mm diameter ditto 8 m

D 25 mm diameter ditto 12 m

E 20 mm diameter ditto 10 m

F 15 mm diameter ditto 18 m
Valve and ancillaries including joints to pipeworks

G 32 mm diameter gate valve 3 no

H 25 mm diameter ditto 1 no

I 20 mm diameter ditto 1 no

J 25 mm diameter floating valve 1 no

K 15 mm diameter faucet 1 no

Toilet grid J - U / 4 - 5

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

L 32 mm diameter pipework 8 m

M 25 mm diameter ditto 9 m

N 20 mm diameter ditto 11 m

O 15 mm diameter ditto 96 m

COLD WATER SYSTEM To Collection Rp.

BASEMENT 3

SWIMMING POOL

Supply and install the following swimming pool


equipment complete with supporting frame, innertia
block, spring mounting and all necessary accessories
as specified

A Pool system 1 ls
SWIMMING POOL To Collection Rp.

BASEMENT 3

WASTE & DRAIN WATER SYSTEM

EQUIPMENT

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A Sewage pump (SWP-3A/B), summersible open 1 set


impeller type, capacity 300 lpm, head 20 m, power 7.5
Kw/380/3/50Hz, parallel alternate, non-clog, complete
with control panel valve,floating switches and
accesories (2 units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

B 150 mm diameter, pipework 46 m

Extra over pipework

C Bend 45 degree, 150 mm diameter 20 no

D Bend 90 degree, 150 mm diameter 4 no

KITCHEN DRAIN
Supply and install Cast Iron pipe, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

E 150 mm diameter, pipework 15 m

Extra over pipework

F Bend 45 degree, 150 mm diameter 4 no

G Bend 90 degree, 150 mm diameter 1 no

WASTE & DRAIN WATER SYSTEM To Collection Rp.

BASEMENT 3

WASTE & DRAIN WATER SYSTEM (Cont'd)

Toilet grid J - U / 4 - 5

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

A 150 mm diameter, pipework 8 m

B 100 mm diameter, ditto 34 m

C 80 mm diameter, ditto 13 m

D 65 mm diameter, ditto 28 m

E 50 mm diameter, ditto 37 m

Extra over pipework

F Bend 45 degree, 150 mm diameter 1 no

G Bend 45 degree, 100 mm diameter 6 no

H Bend 45 degree, 65 mm diameter 8 no

I Bend 90 degree, 150 mm diameter 1 no

J Bend 90 degree, 100 mm diameter 6 no

K Tee diameter 150 x 150 x 100 mm 3 no

L Tee diameter 100 x 100 x 100 mm 2 no

M Tee diameter 100 x 100 x 50 mm 4 no

N Tee diameter 80 x 80 x 65 mm 2 no

O Tee diameter 80 x 80 x 50 mm 3 no

P Tee diameter 65 x 65 x 65 mm 1 no

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 3
WASTE & DRAIN WATER SYSTEM ( Cont'd)

Toilet grid J - U / 4 - 5

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

A 65 mm diameter, pipework 22 m

B 50 mm diameter, ditto 37 m

C 40 mm diameter, ditto 16 m

D 32 mm diameter, ditto 15 m

Extra over pipework

E Bend 45 degree, 65 mm diameter 1 no

F Tee diameter 65 x 65 x 50 mm 2 no

Valve and ancillaries including joints to pipeworks

G 80 mm diameter, Clean out 1 no

H 65 mm diameter, clean out 1 no

WASTE & DRAIN WATER SYSTEM ( Cont'd) To Collection Rp.

BASEMENT 3

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

A 200 mm diameter, pipework 40 m

B 150 mm diameter, ditto 135 m

C 100 mm diameter, ditto 67 m

Extra over pipework

D Bend 45 degree, 150 mm diameter 6 no


E Bend 45 degree, 100 mm diameter 4 no

F Tee diameter 200 x 200 x 100 mm 0 no

G Tee diameter 150 x 150 x 100 mm 1 no

H Tee diameter 100 x 100 x 100 mm 9 no

I Tee diameter 150 x 150 x 150 mm 10 no

J Bend 90 degree, 150 mm diameter 1 no

K Bend 90 degree, 100 mm diameter 14 no

Valve and ancillaries including joints to pipeworks

L 100 mm diameter planter drain 11 no

M 100 mm diameter floor drain 4 no

RAIN WATER SYSTEM To Collection Rp.

BASEMENT 3

COLLECTION

COLD WATER SYSTEM Rp.

SWIMMING POOL Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM ( Cont'd) Rp.

RAIN WATER SYSTEM Rp.


BASEMENT 3 To Collection Rp.

BASEMENT 2

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 65 mm diameter, pipework 3 m

B 50 mm diameter, ditto 47 m

C 40 mm diameter, ditto 20 m

D 32 mm diameter, ditto 4 m

E 20 mm diameter, ditto 9 m

F 25 mm diameter, ditto 75 m

G 15 mm diameter, ditto 6 m

Extra over pipework

H Tee diameter 65 x 65 x 65 mm 2 no

I Bend 90 degree, 65 mm diameter 1 no

Valve and ancillaries including joints to pipeworks

J 32 mm diameter gate valve 4 no

K 25 mm diameter ditto 3 no

L 20 mm diameter ditto 2 no

M 25 mm diameter water meter 1 no

N 15 mm diameter, faucet 3 no

COLD WATER SYSTEM To Collection Rp.


BASEMENT 2

COLD WATER SYSTEM (Cont'd)

Area Toilet Grid F - G/ 2 - 6

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 32 mm diameter, pipework 4 m

B 25 mm diameter ditto 2 m

C 20 mm diameter ditto 30 m

D 15 mm diameter ditto 63 m
D 15 mm diameter ditto 2 m

Area Toilet Grid R - U/ 2 - 6

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

E 32 mm diameter, pipework 3 m

F 25 mm diameter ditto 6 m

G 20 mm diameter ditto 12 m

H 15 mm diameter ditto 87 m

Sattelite Kitchen

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

I 25 mm diameter, pipework 20 m

J 20 mm diameter ditto 6 m

K 15 mm diameter ditto 39 m

COLD WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 2

COLD WATER SYSTEM (Cont'd)

Valve and ancillaries including joints to pipeworks


(Cont'd)

A 20 mm diameter gate valve 2 no

B 15 mm diameter, ditto 10 no

Lounge Bar

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

C 20 mm diameter, pipework 8 m
D 15 mm diameter ditto 2 m

Valve and ancillaries including joints to pipeworks


(Cont'd)

E 15 mm diameter gate valve 1 no

COLD WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 2

HOT WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 50 mm diameter, pipework 16 m

B 25 mm diameter, ditto 12 m

C 20 mm diameter, ditto 48 m

D 15 mm diameter, ditto 3 m

Valve and ancillaries including joints to pipeworks

E 25 mm diameter gate valve 2 no

F 20 mm diameter, ditto 2 no

G 15 mm diameter, ditto 1 no

H 25 mm diameter water meter 1 no

Sattelite Kitchen

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

I 25 mm diameter, pipework 20 m

J 20 mm diameter ditto 12 m
K 15 mm diameter ditto 16 m

Valve and ancillaries including joints to pipeworks

L 20 mm diameter gate valve 2 no

M 15 mm diameter, ditto 6 no

HOT WATER SYSTEM To Collection Rp.

BASEMENT 2

HOT WATER SYSTEM (Cont'd)

Lounge Bar

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 20 mm diameter, pipework 8 m

B 15 mm diameter ditto 2 m

Valve and ancillaries including joints to pipeworks

C 15 mm diameter gate valve 1 no

HOT WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 2
WASTE & DRAIN WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

A 150 mm diameter, pipework 38 m

B 100 mm diameter, ditto 34 m

Extra over pipework

C Bend 45 degree, 150 mm diameter 5 no

D Bend 45 degree, 100 mm diameter 5 no

KITCHEN DRAIN

Supply and install Cast Iron pipe, fixed in position


complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

E 150 mm diameter, pipework 4 m

F 100 mm diameter, ditto 35 m

Extra over pipework

G Bend 45 degree, 100 mm diameter 5 no

H Tee diameter 150 x 150 x 100 mm 1 no

Area Toilet Grid F - G/ 2 - 6

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

I 150 mm diameter, pipework 8 m

J 100 mm diameter, ditto 20 m

WASTE & DRAIN WATER SYSTEM To Collection Rp.

BASEMENT 2

WASTE & DRAIN WATER SYSTEM (Cont'd)

Area Toilet Grid F - G/ 2 - 6

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

A 80 mm diameter, pipework 23 m

B 65 mm diameter, ditto 23 m

C 50 mm diameter, ditto 20 m

D 40 mm diameter, ditto 14 m

Extra over pipework


E Bend 45 degree, 150 mm diameter 2 no

F Bend 45 degree, 100 mm diameter 5 no

G Tee diameter 150 x 150 x 100 mm 2 no

H Tee diameter 100 x 100 x 100 mm 1 no

I Tee diameter 100 x 100 x 80 mm 1 no

J Tee diameter 80 x 80 x 50 mm 4 no

K Tee diameter 80 x 80 x 40 mm 4 no

L Tee diameter 65 x 65 x 50 mm 3 no

M Tee diameter 65 x 65 x 40 mm 4 no

N 100 mm diameter, clean Out 1 no

O 65 mm diameter, ditto 2 no

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 2

WASTE & DRAIN WATER SYSTEM (Cont'd)

Area Toilet Grid F - G/ 2 - 6

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

A 65 mm diameter, pipework 20 m

B 50 mm diameter, ditto 28 m

C 40 mm diameter, ditto 42 m

Extra over pipework

D Bend 90 degree, 65 mm diameter 1 no

E Tee diameter 65 x 65 x 50 mm 2 no

Area Toilet Grid R - U/ 2 - 6

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

F 150 mm diameter, pipework 4 m

G 100 mm diameter, ditto 23 m

H 80 mm diameter, ditto 17 m
I 65 mm diameter, ditto 16 m

J 50 mm diameter, ditto 7 m

K 40 mm diameter, ditto 5 m

L 32 mm diameter, ditto 14 m

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 2

WASTE & DRAIN WATER SYSTEM (Cont'd)

Area Toilet Grid R - U/ 2 - 6

Extra over pipework

A Bend 45 degree, 150 mm diameter 2 no

B Bend 45 degree, 100 mm diameter 8 no

C Tee diameter 150 x 150 x 100 mm 6 no

D Tee diameter 100 x 100 x 80 mm 1 no

E Tee diameter 80 x 80 x 50 mm 7 no

F Tee diameter 80 x 80 x 40 mm 3 no

G Tee diameter 65 x 65 x 50 mm 6 no

H 80 mm diameter, clean Out 1 no

I 65 mm diameter, ditto 2 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

J 65 mm diameter, pipework 28 m

K 50 mm diameter, ditto 27 m

L 40 mm diameter, ditto 25 m

M 32 mm diameter, ditto 32 m

Extra over pipework

N Bend 90 degree, 65 mm diameter 1 no

O Tee diameter 65 x 65 x 40 mm 2 no

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 2

WASTE & DRAIN WATER SYSTEM (Cont'd)


Satelite Kitchen

Supply and install Cast Iron pipe, fixed in position


complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

A 100 mm diameter, pipework 70 m

B 80 mm diameter, ditto 14 m

C 50 mm diameter, ditto 47 m

Extra over pipework

D Bend 90 degree, 100 mm diameter 11 no

E Bend 45 degree, 100 mm diameter 9 no

F Bend 45 degree, 80 mm diameter 1 no

G Tee diameter 100 x 100 x 100 mm 15 no

H Tee diameter 100 x 100 x 80 mm 1 no

I Tee diameter 100 x 100 x 50 mm 12 no

Valve and ancillaries including joints to pipeworks

J 100 mm diameter , Clean Out 4 no

Lounge Bar

Supply and install Cast Iron pipe, fixed in position


complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

K 100 mm diameter, pipework 15 m

L 50 mm diameter, ditto 8 m

Extra over pipework

M Bend 90 degree, 100 mm diameter 3 no

N Tee diameter 100 x 100 x 50 mm 3 no

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 2

WASTE & DRAIN WATER SYSTEM (Cont'd)

Lounge Bar

Valve and ancillaries including joints to pipeworks

A 100 mm diameter , Clean Out 2 no


WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 2

RAIN WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

A 150 mm diameter, pipework 24 m

B 100 mm diameter, pipework 100 m

Extra over pipework

Bend 45 degree, 100 mm diameter 12 no

Bend 90 degree, 100 mm diameter 9 no

N Tee diameter 100 x 100 x 100 mm 11 no

Valve and ancillaries including joints to pipeworks

100 mm diameter , plenter drain 18 no


RAIN WATER SYSTEM To Collection Rp.

BASEMENT 2

GAS SYSTEM

PIPEWORK

Gas Pipeworks, type Black Steel Pipe Seamless SCH


40 API 5 L Grade B including support, etc; as
specified.

A 50 mm diameter, pipework 4 m

B 15 mm diameter, ditto 14 m

Satellite Kitchen

Gas Pipeworks, type Black Steel Pipe Seamless SCH


40 API 5 L Grade B including support, etc; as
specified.

C 25 mm diameter, pipework 10 m

D 15 mm diameter, ditto 6 m

Gas Pipeworks Accessories, including connection,


gaskets, etc as required.

E 15 mm diameter , Ball Valve 6 no

GAS SYSTEM To Collection Rp.

BASEMENT 2

POND SYSTEM
Supply and install the following pond system
equipment and installation complete with supporting
frame, innertia block, spring mounting and all
necessary accessories as specified

A pond system 1 ls

POND SYSTEM To Collection Rp.

BASEMENT 2

COLLECTION

COLD WATER SYSTEM Rp.

COLD WATER SYSTEM (Cont'd) Rp.

COLD WATER SYSTEM (Cont'd) Rp.

HOT WATER SYSTEM Rp.

HOT WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

RAIN WATER SYSTEM Rp.

GAS SYSTEM Rp.

POND SYSTEM Rp.


BASEMENT 2 To Collection Rp.

BASEMENT 1

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 80 mm diameter pipework 48 m

B 50 mm diameter, ditto 19 m

C 40 mm diameter, ditto 20 m

D 25 mm diameter, ditto 15 m

E 20 mm diameter, ditto 6 m

F 15 mm diameter, ditto 43 m

Extra over pipework

G Bend 90 degree, 80 mm diameter 2 no

H Tee diameter 80 x 80 x 80 mm 1 no

I Tee diameter 80 x 80 x 50 mm 1 no

J Tee diameter 80 x 80 x 40 mm 1 no

Valve and ancillaries including joints to pipeworks

K 50 mm diameter gate valve 2 no

L 25 mm diameter ditto 4 no

M 20 mm diameter ditto 1 no

N 15 mm diameter ditto 2 no

O 50 mm diameter water meter 1 no

P 25 mm diameter ditto 2 no

Q 15 mm diameter, faucet 4 no

COLD WATER SYSTEM To Collection Rp.


BASEMENT 1

COLD WATER SYSTEM (Cont'd)

Toilet grid Q-V / 14 - 17

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 40 mm diameter pipework 4 m

B 32 mm diameter ditto 4 m

C 25 mm diameter ditto 4 m

D 20 mm diameter ditto 16 m

E 15 mm diameter ditto 80 m

Valve and ancillaries including joints to pipeworks

F 40 mm diameter gate valve 1 no

G 32 mm diameter ditto 1 no

Staff Canteen

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

H 25 mm diameter pipework 10 m

I 20 mm diameter ditto 15 m

J 15 mm diameter ditto 17 m

Valve and ancillaries including joints to pipeworks

K 20 mm diameter gate valve 1 no

L 15 mm diameter ditto 6 no

COLD WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 1

COLD WATER SYSTEM (Cont'd)

Kitchen

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 50 mm diameter pipework 8 m

B 40 mm diameter ditto 21 m

C 32 mm diameter ditto 14 m

D 25 mm diameter ditto 16 m
E 20 mm diameter ditto 28 m

F 15 mm diameter ditto 119 m

Valve and ancillaries including joints to pipeworks

G 20 mm diameter gate valve 4 no

H 15 mm diameter ditto 25 no

Speciality Restaurant

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

I 40 mm diameter pipework 3 m

J 20 mm diameter ditto 6 m

K 15 mm diameter ditto 26 m

Valve and ancillaries including joints to pipeworks

L 20 mm diameter gate valve 1 no

M 15 mm diameter ditto 3 no

COLD WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 1

HOT WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification
A 50 mm diameter pipework 48 m

B 40 mm diameter , ditto 19 m

C 25 mm diameter ditto 10 m

D 20 mm diameter ditto 6 m

E 15 mm diameter ditto 12 m

Valve and ancillaries including joints to pipeworks

F 40 mm diameter gate valve 2 no

G 25 mm diameter ditto 4 no

H 20 mm diameter ditto 1 no

I 15 mm diameter ditto 2 no

J 40 mm diameter water meter 1 no

K 25 mm diameter ditto 2 no

Staff Canteen
Supply and install polypropylene PN 20, fixed in
position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

L 25 mm diameter pipework 10 m

M 20 mm diameter ditto 15 m

N 15 mm diameter ditto 17 m

HOT WATER SYSTEM To Collection Rp.

BASEMENT 1

HOT WATER SYSTEM (Cont'd)

Staff Canteen

Valve and ancillaries including joints to pipeworks


(Cont'd)

A 20 mm diameter gate valve 1 no

B 15 mm diameter ditto 3 no

Kitchen

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

C 40 mm diameter pipework 13 m

D 32 mm diameter , ditto 11 m

E 25 mm diameter ditto 4 m

F 20 mm diameter ditto 34 m

G 15 mm diameter ditto 96 m

Valve and ancillaries including joints to pipeworks

H 20 mm diameter gate valve 2 no

I 15 mm diameter ditto 19 no

Speciality Restaurant

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

J 40 mm diameter pipework 3 m

K 20 mm diameter ditto 6 m

L 15 mm diameter ditto 25 m

HOT WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 1
HOT WATER SYSTEM (Cont'd)

Speciality Restaurant

Valve and ancillaries including joints to pipeworks

A 20 mm diameter gate valve 1 no

B 15 mm diameter ditto 3 no

HOT WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 1

WASTE & DRAIN WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

Sewage pump (SWP-1A/B), summersible open


impeller type, capacity 200 lpm, head 25 m, power 7.5
A Kw/380/3/50Hz, parallel alternate, non-clog, complete 1 set
with control panel valve,floating switches and
accesories (2 units/set)

RISER & DISTRIBUTION PIPEWORK


Supply and install Unplasticised Polyvinyl chloride
( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

B 150 mm diameter, pipework 34 m

C 100 mm diameter, ditto 125 m

Extra over pipework

D Bend 90 degree, 100 mm diameter 2 no

E Bend 45 degree, 100 mm diameter 6 no

F Tee diameter 150 x 150 x 100 mm 1 no

G Tee diameter 100 x 100 x 100 mm 4 no

Valve and ancillaries including joints to pipeworks

H 150 mm diameter, clean out 1 no

I 100 mm diameter, clean out 2 no

WASTE & DRAIN WATER SYSTEM To Collection Rp.

BASEMENT 1

WASTE & DRAIN WATER SYSTEM (Cont'd)

KITCHEN DRAIN

Supply and install Cast Iron pipe, fixed in position


complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

A 150 mm diameter, pipework 20 m

B 100 mm diameter, ditto 64 m

Extra over pipework

C Bend 45 degree, 100 mm diameter 8 no

D Tee diameter 150 x 150 x 100 mm 1 no

E Tee diameter 100 x 100 x 100 mm 7 no

Valve and ancillaries including joints to pipeworks

F 100 mm diameter, clean out 2 no

Toilet grid Q-V / 14 - 17

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

G 100 mm diameter, pipework 28 m


H 80 mm diameter, ditto 10 m

I 65 mm diameter, ditto 16 m

J 50 mm diameter, ditto 4 m

K 40 mm diameter, ditto 10 m

L 32 mm diameter, ditto 20 m

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 1

WASTE & DRAIN WATER SYSTEM (Cont'd)

Toilet grid Q-V / 14 - 17

Extra over pipework

A Bend 90 degree, 100 mm diameter 4 no

B Bend 45 degree, 100 mm diameter 4 no

C Bend 45 degree, 80 mm diameter 2 no

D Bend 45 degree, 65 mm diameter 1 no

E Tee diameter 100 x 100 x 100 mm 4 no

F Tee diameter 100 x 100 x 80 mm 2 no

G Tee diameter 100 x 100 x 65 mm 1 no

H Tee diameter 80 x 80 x 80 mm 2 no

I Tee diameter 80 x 80 x 65 mm 2 no

J Tee diameter 80 x 80 x 50 mm 8 no

K Tee diameter 65 x 65 x 40 mm 4 no

L Tee diameter 65 x 65 x 32 mm 8 no

Valve and ancillaries including joints to pipeworks

M 100 mm diameter, clean out 2 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

N 65 mm diameter, pipework 8 m

O 50 mm diameter, ditto 28 m

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.


BASEMENT 1

WASTE & DRAIN WATER SYSTEM (Cont'd)

Toilet grid Q-V / 14 - 17

VENT PIPEWORK ( Cont,d)

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

A 40 mm diameter, pipework 10 m

B 32 mm diameter, ditto 16 m

Extra over pipework

C Bend 90 degree, 65 mm diameter 1 no

D Tee diameter 65 x 65 x 50 mm 2 no

E Vent cup 1 no

Staff Canteen

Supply and install Cast Iron pipe, fixed in position


complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

F 100 mm diameter, pipework 21 m

G 50 mm diameter, ditto 12 m

Extra over pipework

H Bend 90 degree, 100 mm diameter 2 no

I Bend 45 degree, 100 mm diameter 2 no

J Tee diameter 100 x 100 x 50 mm 4 no

Valve and ancillaries including joints to pipeworks

K 100 mm diameter, clean out 1 no

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 1

WASTE & DRAIN WATER SYSTEM (Cont'd)

Kitchen

Supply and install Cast Iron pipe, fixed in position


complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

A 150 mm diameter, pipework 36 m

B 100 mm diameter, ditto 59 m

C 80 mm diameter, ditto 19 m

D 65 mm diameter, ditto 13 m
E 50 mm diameter, ditto 54 m

F 40 mm diameter, ditto 15 m

G 25 mm diameter, ditto 5 m

Extra over pipework

H Bend 90 degree, 100 mm diameter 14 no

I Bend 45 degree, 150 mm diameter 4 no

J Bend 45 degree, 100 mm diameter 15 no

K Tee diameter 150 x 150 x 150 mm 2 no

L Tee diameter 150 x 150 x 100 mm 6 no

M Tee diameter 150 x 150 x 65 mm 3 no

N Tee diameter 150 x 150 x 40 mm 1 no

O Tee diameter 100 x 100 x 100 mm 12 no

P Tee diameter 80 x 80 x 50 mm 8 no

Q Tee diameter 80 x 80 x 40 mm 1 no

R Tee diameter 80 x 80 x 25 mm 1 no

S Tee diameter 65 x 65 x 40 mm 1 no

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 1

WASTE & DRAIN WATER SYSTEM (Cont'd)

Kitchen

Valve and ancillaries including joints to pipeworks

A 150 mm diameter, clean out 2 no

B 100 mm diameter, clean out 3 no

C 80 mm diameter, clean out 2 no

D 65 mm diameter, clean out 1 no

Speciality Restaurant

Supply and install Cast Iron pipe, fixed in position


complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

E 100 mm diameter, pipework 34 m

F 50 mm diameter, ditto 8 m

G 40 mm diameter, ditto 3 m

Extra over pipework

H Bend 90 degree, 100 mm diameter 5 no

I Bend 45 degree, 100 mm diameter 3 no

J Tee diameter 100 x 100 x 100 mm 3 no


K Tee diameter 100 x 100 x 50 mm 3 no

L Tee diameter 100 x 100 x 100 mm 1 no

Valve and ancillaries including joints to pipeworks

M 100 mm diameter, clean out 2 no

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

BASEMENT 1

RAIN WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

A 150 mm diameter, pipework 32 m

B 100 mm diameter, pipework 88 m

Extra over pipework

C Bend 90 degree, 100 mm diameter 12 no

D Bend 45 degree, 100 mm diameter 6 no

E Tee diameter 150 x 150 x 100 mm 7 no

F Tee diameter 100 x 100 x 100 mm 6 no

Valve and ancillaries including joints to pipeworks

100 mm diameter, planter drain 14 no

RAIN WATER SYSTEM To Collection Rp.

BASEMENT 1
GAS SYSTEM

PIPEWORK

Gas Pipeworks, type Black Steel Pipe Seamless SCH


40 API 5 L Grade B including support, etc; as
specified.

A 50 mm diameter, pipework 92 m

B 40 mm diameter, ditto 14 m

C 25 mm diameter, ditto 2 m

D 20 mm diameter, ditto 16 m

Gas Pipeworks Accessories, including connection,


gaskets, etc as required.

E 40 mm diameter , Ball Valve 1 no

F 25 mm diameter , Ball Valve 1 no

Staff Canteen

Gas Pipeworks, type Black Steel Pipe Seamless SCH


40 API 5 L Grade B including support, etc; as
specified.

G 25 mm diameter, pipework 8 m

H 20 mm diameter, ditto 6 m

I 15 mm diameter, ditto 4 m

Gas Pipeworks Accessories, including connection,


gaskets, etc as required.

J 25 mm diameter , Ball Valve 1 no

K 20 mm diameter , Ball Valve 2 no

L 15 mm diameter , Ball Valve 2 no

GAS SYSTEM To Collection Rp.

BASEMENT 1

GAS SYSTEM (Cont'd)

Kitchen

PIPEWORK

Gas Pipeworks, type Black Steel Pipe Seamless SCH


40 API 5 L Grade B including support, etc; as
specified.

A 40 mm diameter, pipework 12 m

B 32 mm diameter, ditto 16 m

C 25 mm diameter, ditto 1 m

D 20 mm diameter, ditto 1 m
E 15 mm diameter, ditto 8 m

Gas Pipeworks Accessories, including connection,


gaskets, etc as required.

F 25 mm diameter , Ball Valve 1 no

G 20 mm diameter , Ball Valve 1 no

H 15 mm diameter , Ball Valve 8 no

Speciality Restaurant

PIPEWORK

Gas Pipeworks, type Black Steel Pipe Seamless SCH


40 API 5 L Grade B including support, etc; as
specified.

I 20 mm diameter, pipework 4 m

J 15 mm diameter, ditto 2 m

Gas Pipeworks Accessories, including connection,


gaskets, etc as required.

K 20 mm diameter , Ball Valve 1 no

L 15 mm diameter , Ball Valve 1 no

GAS SYSTEM (Cont'd) To Collection Rp.

BASEMENT 1

POND SYSTEM

Supply and install the following pond system


equipment and installation complete with supporting
frame, innertia block, spring mounting and all
necessary accessories as specified

A pond system 1 ls
POND SYSTEM To Collection Rp.

BASEMENT 1

COLLECTION

COLD WATER SYSTEM Rp.

COLD WATER SYSTEM (Cont'd) Rp.

COLD WATER SYSTEM (Cont'd) Rp.

HOT WATER SYSTEM Rp.

HOT WATER SYSTEM (Cont'd) Rp.

HOT WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

RAIN WATER SYSTEM Rp.

GAS SYSTEM Rp.

GAS SYSTEM (Cont'd) Rp.

POND SYSTEM Rp.

BASEMENT 1 To Collection Rp.

GROUND FLOOR

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK


Supply and install polypropylene PN 16, fixed in
position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 100 mm diameter pipework 23 m

B 80 mm diameter , ditto 4 m

C 50 mm diameter , ditto 42 m

D 40 mm diameter , ditto 12 m

E 32 mm diameter , ditto 22 m

F 25 mm diameter , ditto 15 m

G 20 mm diameter , ditto 20 m

H 15 mm diameter , ditto 39 m

Extra over pipework

I Bend 90 degree, 100 mm diameter 3 no

J Tee diameter 100 x 100 x 50 mm 1 no

K Tee diameter 100 x 100 x 40 mm 1 no

L Tee diameter 80 x 80 x 80 mm 1 no

M Reducer diameter 100 x 80 mm 1 no

Valve and ancillaries including joints to pipeworks

N 32 mm diameter gate valve 2 no

O 25 mm diameter ditto 1 no

P 20 mm diameter ditto 2 no

Q 15 mm diameter , faucet 4 no

COLD WATER SYSTEM To Collection Rp.

GROUND FLOOR

COLD WATER SYSTEM (CONT'D)

Toilet grid Q-cB / 5 - 6

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 32 mm diameter pipework 8 m

B 25 mm diameter , ditto 2 m

C 20 mm diameter , ditto 31 m

D 15 mm diameter , ditto 42 m

Toilet grid cA-H / 18 - 20


Supply and install polypropylene PN 16, fixed in
position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

E 25 mm diameter pipework 4 m

F 20 mm diameter , ditto 8 m

G 15 mm diameter , ditto 12 m

COLD WATER SYSTEM (CONT'D) To Collection Rp.

GROUND FLOOR

HOT WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification
A 50 mm diameter pipework 4 m

B 20 mm diameter , ditto 54 m

Valve and ancillaries including joints to pipeworks

C 20 mm diameter gate valve 1 no


HOT WATER SYSTEM To Collection Rp.

GROUND FLOOR

WASTE & DRAIN WATER SYSTEM

EQUIPMENT

Supply and install septictank package (Biotek) and


including all necessary supporting accessories as
required in accordance with the specifications,
drawings and manufacturer's instructions as described

Septitank package ( Biotek) with capacity 3 m3


A 1 unit
complete with control box

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

B 150 mm diameter, pipework 86 m

C 100 mm diameter, ditto 104 m

D 80 mm diameter, ditto 94 m

Extra over pipework

E Bend 45 degree, 150 mm diameter 2 no

F Ditto, 100 mm diameter 8 no

G Tee diameter 150 x 150 x 150 mm 1 no

H Tee diameter 150 x 150 x 100 mm 3 no

I Tee diameter 150 x 150 x 80 mm 2 no

Toilet grid Q-cB / 5 - 6

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

J 100 mm diameter, pipework 26 m

K 80 mm diameter, ditto 18 m

WASTE & DRAIN WATER SYSTEM To Collection Rp.

GROUND FLOOR

WASTE & DRAIN WATER SYSTEM (Cont'd)

Toilet grid Q-cB / 5 - 6 ( Cont'd)


Supply and install Unplasticised Polyvinyl chloride
( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

A 65 mm diameter pipework 9 m

B 50 mm diameter, ditto 1 m

C 40 mm diameter, ditto 4 m

D 32 mm diameter, ditto 14 m

Extra over pipework

E Bend 45 degree, 100 mm diameter 8 no

F Ditto, 65 mm diameter 4 no

G Tee diameter 100 x 100 x 100 mm 4 no

H Tee diameter 100 x 100 x 50 mm 1 no

I Tee diameter 80 x 80 x 65 mm 5 no

J Tee diameter 80 x 80 x 32 mm 5 no

Valve and ancillaries including joints to pipeworks

K 100 mm diameter, clean Out 2 no

L 80 mm diameter, ditto 2 no

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

GROUND FLOOR

WASTE & DRAIN WATER SYSTEM (Cont'd)

Toilet grid Q-cB / 5 - 6 ( Cont'd)

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

A 65 mm diameter, pipework 8 m

B 50 mm diameter, ditto 29 m

C 40 mm diameter, ditto 7 m

D 32 mm diameter, ditto 6 m

Extra over pipework

E Bend 90 degree, 65 mm diameter 1 no


F Tee diameter 65 x 65 x 50 mm 1 no

G Vent cup 1 no

Toilet grid cA-H / 18 - 20

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

H 100 mm diameter, pipework 6 m

I 80 mm diameter, ditto 4 m

J 65 mm diameter, ditto 1 m

K 40 mm diameter, ditto 10 m

L 32 mm diameter, ditto 5 m

WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

GROUND FLOOR

WASTE & DRAIN WATER SYSTEM

Toilet grid cA-H / 18 - 20 ( Cont'd)

Extra over pipework

A Bend 45 degree, 100 mm diameter 4 no

B Ditto, 65 mm diameter 2 no

C Tee diameter 100 x 100 x 100 mm 2 no

D Tee diameter 100 x 100 x 40 mm 1 no

E Tee diameter 80 x 80 x 65 mm 2 no

F Tee diameter 80 x 80 x 40 mm 1 no

Valve and ancillaries including joints to pipeworks

G 100 mm diameter, clean Out 1 no

H 80 mm diameter, ditto 1 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

I 50 mm diameter, pipework 12 m

J 32 mm diameter, ditto 6 m

Extra over pipework

K Vent cup 1 no
WASTE & DRAIN WATER SYSTEM (Cont'd) To Collection Rp.

GROUND FLOOR

GAS SYSTEM

PIPEWORK

Gas Pipeworks, type Black Steel Pipe Seamless SCH


40 API 5 L Grade B including support, etc; as
specified.

A Header Pipe with 10 Connections, 1 no

B 50 mm diameter, pipework 68 m

Gas Pipeworks Accessories, including connection,


gaskets, etc as required.

C Approve diameter , Ball Valve 4 no

D Approve diameter , Gate Valve 1 no

E Approve diameter , Check Valve 1 no

F Approve diameter , automatic change over switch


control 1 no

G Approve diameter , presure switch 1 no

H Approve diameter , selenoid valve 1 no

I Pressure Gauge c/w valve 1 no

J Pigtail Hose 1/4 x 100 include copling 10 no

K Manifold 10 no

L LPG tube 50 Kg 10 no

GAS SYSTEM To Collection Rp.

GROUND FLOOR

POND SYSTEM

Supply and install the following pond system


equipment and installation complete with supporting
frame, innertia block, spring mounting and all
necessary accessories as specified
A pond system 1 ls

POND SYSTEM To Collection Rp.

GROUND FLOOR

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification
150 mm diameter, pipework 28 m

100 mm diameter, ditto 101 m

Extra over pipework

Bend 90 degree, 100 mm diameter 6 no

Bend 45 degree, 100 mm diameter 27 no

Tee diameter 150 x 150 x 100 mm 6 no

Tee diameter 100 x 100 x 100 mm 8 no


RAIN WATER SYSTEM To Collection Rp.

GROUND FLOOR

COLLECTION

COLD WATER SYSTEM Rp.

COLD WATER SYSTEM (CONT'D) Rp.

HOT WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

WASTE & DRAIN WATER SYSTEM (Cont'd) Rp.

GAS SYSTEM Rp.

POND SYSTEM Rp.

RAIN WATER SYSTEM Rp.

GROUND FLOOR To Collection Rp.

COLD WATER SYSTEM

SPA AREA ( PUMP ROOM )

PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 25 mm diameter Header, with ± 7 m length 1 no


B 25 mm diameter pipework 16 m

C 20 mm diameter ditto 20 m

Valve and ancillaries including joints to pipeworks

D 25 mm diameter gate valve 2 no

E 25 mm diameter powered control valve 1 no

F 25 mm diameter check valve 1 no

G 25 mm diameter water mur 1 no

KITCHEN & LAUNDRY AREA ( PUMP ROOM )


PIPEWORK
Supply and install polypropylene PN 16, fixed in
position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

H 50 mm diameter Header, with ± 7 m length 1 no

I 40 mm diameter pipework 20 no

J 20 mm diameter ditto 40 no

Valve and ancillaries including joints to pipeworks

K 40 mm diameter gate valve 2 no

L 40 mm diameter powered control valve 1 no

M 40 mm diameter check valve 1 no

N 40 mm diameter water mur 1 no

COLD WATER SYSTEM To Collection Rp.

HOT WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

SPA AREA

A Head pump 1 & 2 , Heating capacity 4.8 Kw , rated input 2 unit


power 1.3 Kw /220/1/50Hz, Rated hot water output 120
L/h, Max. water temperatur 55 C, model : WIKA-HPR
4.8-130P, complete with control panel, valve and
accessories.

B Presure hot water tank, capacity 500 L, presurized 2 unit


vertical tank type, inner tank - plate = 2 mm enamel coat,
working presure maximal 4 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model WIKA-500-P. complete with electric
heater,sensor, valve, safety valve, and accessories.

C Circulation Hot water pump (PBAP-05A/B), centrifugal 1 SET


end suction type, capacity 100 lpm, head 10 m, power
0.4 Kw/220/1/50Hz, pararel altenate, complete with
control panel, valve,header and accessories. (2
units/set)

PIPEWORK
Supply and install polypropylene PN 20, fixed in
position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

D 20 mm diameter Header, with ± 7 m length 1 no

E 25 mm diameter pipework 16 m

F 20 mm diameter ditto 20 m

G 15 mm diameter ditto 12 m

Valve and ancillaries including joints to pipeworks

H 25 mm diameter gate valve 1 no

I 15 mm diameter gate valve 3 no

J 15 mm diameter powered control valve 1 no

K 15 mm diameter check valve 1 no

L 15 mm diameter water mur 1 no

HOT WATER SYSTEM To Collection Rp.

HOT WATER SYSTEM (Cont'd)

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

KITCHEN & LAUNDRY AREA

A Head pump 1,2 , Heating capacity 9.6 Kw , rated input 2 unit


power 2.6 Kw /220/1/50Hz, Rated hot water output 140
L/h, Max. water temperatur 55 C, model : WIKA-HPR
9.6-260P, complete with control panel, valve and
accessories

B Presure hot water tank, capacity 500 L, presurized 8 unit


vertical tank type, inner tank - plate = 2 mm enamel coat,
working presure maximal 4 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model WIKA-500-P. complete with electric
heater,sensor, valve, safety valve, and accessories

C Circulation Hot water pump (PBAP-06A/B), centrifugal 1 SET


end suction type, capacity 100 lpm, head 10 m, power
0.4 Kw/220/1/50Hz, pararel altenate, complete with
control panel, valve,header and accessories. (2
units/set)

PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

D 50 mm diameter Header, with ± 7 m length 1 no

E 50 mm diameter pipework 20 m

F 20 mm diameter ditto 40 m

Valve and ancillaries including joints to pipeworks

H 50 mm diameter gate valve 1 no


HOT WATER SYSTEM (Cont'd) To Collection Rp.

ASSOCIATED ELECTRICAL WORK

SPA AREA

A Supply and install cable complete with termination, 8 no


splices, tags, conduit and all necessary supporting
accessories

KITCHEN & LAUNDRY AREA

B Supply and install cable complete with termination, 19 no


splices, tags, conduit and all necessary supporting
accessories

ASSOCIATED ELECTRICAL WORK To Collection Rp.

SPA AREA ( PUMP ROOM )

COLLECTION

COLD WATER SYSTEM Rp.

HOT WATER SYSTEM Rp.

HOT WATER SYSTEM (Cont'd) Rp.

ASSOCIATED ELECTRICAL WORK Rp.

SPA PUMP ROOM To Collection Rp.

Sanitary Fitting

Install the following sanitary fixtures complete with


all necessary fittings and joints to pipework as
specified

Lobby and lounge public toilet

A WC with eco washer 5 no

B Urinal with auto detector 2 no


C Urinal divider 2 no

D Washhand basin 4 no

E Washhand basin mixer 4 no

F Floor outlet 7 no

Cigar lounge toilet

G WC with eco washer 2 no

H Urinal with auto detector 0 no

I Urinal divider 0 no

J Washhand basin 2 no

K Washhand basin mixer 2 no

L Floor outlet 4 no

To Collection Rp.

Sanitary Fitting cont'd

ADD restaurant toilet

A WC with eco washer 5 no

B Urinal with auto detector 2 no

C Urinal divider 2 no

D Washhand basin 6 no

E Washhand basin mixer 6 no

F Janitor sink with mixer 1 no

G Floor outlet 7 no

Function toilet

H WC with eco washer 6 no

I Urinal with auto detector 4 no

J Urinal divider 4 no

K Washhand basin 6 no

L Washhand basin mixer 6 no

M Floor outlet 8 no

Changing room
N WC and eco washer 6 no

O Washhand basin 7 no

P Washhand basin mixer 7 no

Q Urinal with auto detector 4 no

R Urinal divider 4 no

S Rain shower head, hand shower and thermostatic


mixer 5 no

T Floor outlet 13 no

To Collection Rp.

Sanitary Fitting cont'd

A BOH area

B WC with eco washer 7 no

C Urinal with auto detector 4 no

D Urinal divider 4 no

E Washhand basin 11 no

F Washhand basin mixer 11 no

G Shower head, hand shower and thermostatic mixer 4 no

H Wall tap for ablution 4 no

I Floor outlet 18 no

Spa treatment rooms

J WC and eco washer 6 no

K Custom-made terrazzo basin LF-18 17 no

L Washhand basin mixer 17 no

M Custom-made terrazzo bathtub LF-19 2 no

N Bathtub mixer 2 no

O Rain shower head, hand shower and thermostatic


mixer 5 no

P Floor outlet 15 no

Back-of-house Spa treatment rooms

Q WC with eco washer 1 no

R Washhand basin 1 no

S Washhand basin mixer 1 no

T Kitchen sink with tapware 1 no

U Floor outlet 2 no

To Collection Rp.

Collection

Page/Page
Page/Page

Page/Page

Sanitary Fitting To Collection Rp.

COLLECTION

BASEMENT 5 Rp.

BASEMENT 4 Rp.

BASEMENT 3A Rp.

BASEMENT 3 Rp.

BASEMENT 2 Rp.

BASEMENT 1 Rp.

GROUND FLOOR Rp.

SPA PUMP ROOM Rp.

Sanitary Fitting Rp.


SUB BILL NO. 2.11 : PLUMBING INSTALLATION To Summary Bill No 2 Rp.

BILL NO. 2: MAIN BUILDING


SUMMARY

Code Description Quantity Unit

SUMMARY BILL 2

SUB BILL NO.2.1 : SUBSTRUCTURE

SUB BILL NO.2.2 : UPPER STRUCTURE

SUB BILL NO.2.3 : ROOFING

SUB BILL NO.2.4: STAIR FINISHES

SUB BILL NO.2.5 : EXTERNAL WALL & FINISHES

SUB BILL NO.2.6 : INTERNAL WALL

SUB BILL NO.2.7 : DOORS & WINDOWS

SUB BILL NO.2.8 : WALL FINISHES

SUB BILL NO.2.9 : FLOOR FINISHES

SUB BILL NO.2.10 : CEILING FINISHES

SUB BILL NO. 2.11 : PLUMBING INSTALLATION


SUMMARY NO. 2 : MAIN BUILDING Summary Bill No. 2 Rp.
BILL NO. 3: HOTEL
SUB BILL NO. 3.1: SUB STRUCTURE
ORIGINAL

Quantity Unit
Code Description

General

A Allow for providing all plant and equipment on site for 1 ls


the installation of the piles including moving the plant
and equipment about the site, the provision of
temporary supports as required during the execution of
the works and for removing the plant and equipment
from site on completion of the works

B Allow for submission of records in triplicate of all bored 1 ls


piles installed, duly signed by the Contractor and
deliver to the Project Manager as the work proceeds

C Allow for the submission of a drawing showing the final 1 ls


plan position of each pile reference by a serial number
and the levels of the bottom and top of each pile as
installed

Bored Tension Piles

Note:
Bored pile, 400mm diameter (195 no)

D Boring, 400mm diameter from basement level to 2,340 m


proposed bored pile level (12 m)

E Install temporary caison / liner as necessary and 195 no


subsequently remove

F Concrete filling (f'c = 24.9 MPa), to 400mm diameter 130 m3


pile (12 m)

G General reinforcing bar 13 mm diameter 19,505 kg

H General reinforcing bar 10 mm diameter 16,408 kg

I Remove surplus excavated material/soil disposal from 294 m3


site

J Backfill blind bore with excavated material 294 m3

To Collection

Pile Testing

A Allow for providing and mobilizing all necessary 1 ls


equipment, materials and labour to carry out axial and
lateral load tests

B Carry out axial compressive loading test by Kentledge 1 no


method on 400mm diameter pile

C Carry out axial compressive loading test by Kentledge 1 no


method on 400mm diameter pile
D Carry out axial load test by the PDA test including 1 no
CAPWAP analysis on working pile size 400mm
diameter

E Carry out PIT test on working pile size 400mm 1 no


diameter ramdomly

F Clean up and remove load testing equipment from site 1 ls


on completion of the load testing works

G Allow for recording results and providing reports as 1 ls


specified

To Collection

Excavation

Note: The quantities given are the net volume, allowance for
additional excavation and backfilling to provide working space shall
be included in the unit rates

A Excavation for basement commencing from existing 0 m3


ground level

B Ditto for pile caps 101 m3

C Ditto for ground slab 0 m3

Soil disposal and backfilling

D Remove surplus excavated material from site 101 m3

E Backfilling including compaction in layers to trenches 11 m3

Compacted sand bed

F 100mm thick compacted sand layer under basement 8,037 m2


slab

G Ditto for pile caps 202 m2

H Ditto for ground slab 955 m2

Lean concrete 1:3:5


I 50mm thick blinding layer under basement slab 8,037 m2

J Ditto for pile caps 202 m2

K Ditto for ground slab 955 m2

To Collection

Termite treatment as specified

A Apply termite treatment 202 m2

Vibrated reinforced concrete f'c = 24.9 Mpa

B Pile caps 101 m3


To Collection

COLLECTION

Page 6/3.1/1 Rp.

Page 6/3.1/2 Rp.

Page 6/3.1/3 Rp.

Page 6/3.1/4 Rp.

SUB BILL NO. 3.1: SUB STRUCTURE Summary Bill No. 3 Rp.

BILL NO. 3: HOTEL


SUB BILL NO. 3.2: UPPER STRUCTURE

Quantity Unit
Code Description

Vibrated reinforced concrete f'c = 24.9 Mpa

A Basement slab 1,031 m3

B Basement wall (provisional) 839 m3

C Ground wall 104 m3

D Ground slab 36 m3

E Suspended beam over basement 412 m3

F Column 141 m3

Bar reinforcement; deformed high tensile BJTD-40,


including bending, cutting to length and supplying and
installing all tying wire, accessories and consumable

G General reinforcing bars in pile caps; 16mm diameter 4,241 kg


(provisional)

H Ditto; 13mm diameter (provisional) 7,128 kg

I General reinforcing bars in basement slabs 123,670 kg


(provisional)
J General reinforcing bars in ground slabs (provisional) 4,303 kg

K General reinforcing bars in basement columns; 22mm 6,520 kg


diameter

L Ditto; 19mm diameter 19,977 kg

M Ditto; 16mm diameter 4,772 kg

N General reinforcing bars in basement walls 125,869 kg


(provisional)
O General reinforcing bars in ground walls (provisional) 15,644 kg

P General reinforcing bars in suspended beams; 22 101,112 kg


mm

Q General reinforcing bars in pile caps; 10mm diameter 5,555 kg


(provisional)

R Stirrups and hooks in columns 10 mm diameter 6,473 kg

Q Ditto; 19 mm diameter 14,419 kg

R Ditto; 16 mm diameter 17,380 kg

S Ditto; 13 mm diameter 568 kg

T Ditto; 10 mm diameter 28,620 kg

To Collection

Formwork

A To sides of pile caps 285 m2

B To sides of basement walls 7,675 m2


C To soffit of basement slabs 8,037 m2

D To soffit of suspended ground slabs 955 m2

E To sides of suspended beams 4,630 m2

F To sides of columns 1,582 m2

G Soffit of landing 133 m2

H Sloping soffit of staircases 180 m2

I Raking sides of stair over 200 mm but not exceeding 973 m


225 mm high including cutting to profile of treads and
risers

J To riser over 150 mm but not exceeding 200 mm high 498 m

Waterproofing

Supply and apply waterproofing integral or equal


approved applied, strictly in accordance with the
manufacturer's instructions

K To sides of pile caps 102 m2

L To soffit of suspended ground slabs 115 m2

M To sides of columns 141 m2


Supply and apply waterproofing membran or equal
N To natural stone (Paras Kerobokan) 903 m2

To Collection

COLLECTION

Page 6/3.2/6 Rp.

Page 6/3.2/7 Rp.


SUB BILL NO. 3.2: UPPER STRUCTURE Summary Bill No. 3 Rp.

BILL NO. 3: HOTEL


SUB BILL NO. 3.3: STAIR FINISHES

Quantity Unit
Code Description

STAIR #1 (B3A - GF)

Cement and sand (1:3) plaster with smooth finish as


specified

A 130 mm thick; to sides and soffits of suspended beam 38 m2

B Ditto; to sides and soffits of staircases 59 m2

Smooth trowelled cement and sand (1:3) screed as


specified

C Surfaces of landing; 50 mm thick 58 m2

D Surfaces of treads; 225 mm wide x 50 mm thick 129 m

Surfaces of undercut risers; not exceeding 200 mm 138 m


E
high x 50 mm thick

Beds, 75 mm wide x 50 mm thick to receive ceramic 138 m


F
nosing tile

Ceramic tile finish with grouting, bedded, jointed and


pointed as specified

G Ceramic nosing tiles 75 mm wide x 50 mm thick 138 m


(created by machine)

Handrails
Mild steel work with welded and bolted connections
and complete with painted finish as described

H 100 x 40 mm solid wood handrail (bengkirai) to stair #1 38 m

I 60 x 40 mm solid wood horizontal railing support 38 m


(bengkirai) to stair #1

J 100 x 40 mm solid wood handrail (bengkirai) fixed to 43 m


wall

60 x 40 mm solid wood horizontal railing support 43 m


K
(bengkirai) fixed to wall

To Collection

STAIR #2 (B4 - GF)

Cement and sand (1:3) plaster with smooth finish as


specified

A 130 mm thick; to sides and soffits of suspended beam 35 m2

B Ditto; to sides and soffits of staircases 55 m2

Smooth trowelled cement and sand (1:3) screed as


specified

C Surfaces of landing; 50 mm thick 38 m2

D Surfaces of treads; 225 mm wide x 50 mm thick 171 m

Surfaces of undercut risers; not exceeding 200 mm 168 m


E
high x 50 mm thick

Beds, 75 mm wide x 50 mm thick to receive ceramic 168 m


F
nosing tile

Ceramic tile finish with grouting, bedded, jointed and


pointed as specified

G Ceramic nosing tiles 75 mm wide x 50 mm thick 168 m


(created by machine)

Handrails

Mild steel work with welded and bolted connections


and complete with painted finish as described

H 100 x 40 mm solid wood handrail (bengkirai) to stair #2 41 m

I 60 x 40 mm solid wood horizontal railing support 41 m


(bengkirai) to stair #2

J 100 x 40 mm solid wood handrail (bengkirai) fixed to 63 m


wall

60 x 40 mm solid wood horizontal railing support 63 m


K
(bengkirai) fixed to wall
To Collection

STAIR #3 (B5 - GF)

Cement and sand (1:3) plaster with smooth finish as


specified

A 130 mm thick; to sides and soffits of suspended beam 35 m2

B Ditto; to sides and soffits of staircases 66 m2

Smooth trowelled cement and sand (1:3) screed as


specified

C Surfaces of landing; 50 mm thick 37 m2

D Surfaces of treads; 225 mm wide x 50 mm thick 178 m

Surfaces of undercut risers; not exceeding 200 mm 189 m


E
high x 50 mm thick

Beds, 75 mm wide x 50 mm thick to receive ceramic 189 m


F
nosing tile

Ceramic tile finish with grouting, bedded, jointed and


pointed as specified

G Ceramic nosing tiles 75 mm wide x 50 mm thick 189 m


(created by machine)

Handrails

Mild steel work with welded and bolted connections


and complete with painted finish as described

H 100 x 40 mm solid wood handrail (bengkirai) to stair #3 41 m

I 60 x 40 mm solid wood horizontal railing support 41 m


(bengkirai) to stair #3

J 100 x 40 mm solid wood handrail (bengkirai) fixed to 63 m


wall

60 x 40 mm solid wood horizontal railing support 63 m


K
(bengkirai) fixed to wall

To Collection

COLLECTION
Rp.
Page 6/3.3/11
Rp.
Page 6/3.3/12
Rp.
Page 6/3.3/13
SUB BILL NO. 3.3: STAIR FINISHES Summary Bill No. 3 Rp.

BILL NO. 3: HOTEL


SUB BILL NO. 3.4: EXTERNAL ENVELOPE

Quantity Unit
Code Description

DOORS AND WINDOWS

Doors

Supply and install aluminium door, complete with


aluminium frames, 8 mm thick tempered clear glass
leaf door, hardwares as specified and all fixing
accessories

A Double sliding door and double fixed panel, overall size 46 no


4250 x 2750 mm at bedroom (D01)

Supply and install 'bengkirai' solid wood doors,


complete with solid timber frames, solid timber jambs,
hardwares as specified and all fixing accessories

B Single pivot door, overall size 1180 x 2400mm at 46 no


entrance (D02)
Supply and install timber doors, complete with solid
timber frames, solid timber jambs, hardwares as
specified and all fixing accessories

C Single sliding door including 20 x 20 mm architrave, 46 no


overall size 1200 x 2500mm at bedroom to bathroom
(D03)

Fixed glass door, 12mm thick tempered clear glass,


overall size 1050 x 2000 mm high complete with all
fixing accessories (D04)

D
To bathroom 92 no

Steel door including hardwares and all necessary


accessories as specified

E Single pivot door, overall size 700 x 1620mm at 46 no


bathroom shaft (D05)

To Collection

Windows

A Fixed glass window, 12 ~ 20 mm thick tempered clear 46 no


glass, overall size 1981 x 2770mm high complete with all
fixing accessories (W01) as shown on dwg AR.U.04.002

B Fixed glass window, 12 ~ 20 mm thick tempered clear 46 no


glass, overall size 1635 x 2770 mm high complete with
all fixing accessories (W02) as shown on dwg
AR.U.04.002

Supply and install solid wood cladding (jati doreng)


size 12 x 70 x L mm, thickness 1.5 mm joist 40 x 60 x L
mm (W1C)

Elevation A

A
To hotel 1 (As.1-6 / B4 - B2') 59 m2

B
To hotel 2 (As.8-13 / B3A' - B2) 59 m2

C
To hotel / Facility (As.14-18 / B3A - B1') 59 m2

D
To hotel 2 (As.7-11 / B2' - B1') 55 m2

Elevation C

E m2
To hotel 1 (As.1 & 6) 40

F m2
To hotel 2 (As.13 & 8) 52

G m2
To hotel 2 (As. 7 & 11) 34

H m2
To hotel 3 / Facility (As.14 & 18) 35
To Collection

Cement and sand (1:3) backing as specified

A
Backing, 25 mm thick to receive natural stone 1,085 m2

B
Backing, 25 mm thick to receive exterior texture finish 4,654 m2

C
Backing, 25 mm thick to receive expose wall 2,382 m2

Supply and install natural stone (Paras Kerobokan)


various plank size honed finish random pattern bedded
and jointed in mortar as specified (W12)

D
To hotel 2 (As.7 & 11) 156 m2

E
To hotel 1 (As.14 & 19) 312 m2

F
To hotel 2 (As.8 & 13) 218 m2

G
To hotel 3 / facility (As.1 & 6) 218 m2

Supply and install natural stone (Paras Kerobokan)


various plank size thicness 1.8 mm joist 40 x 60 x L
mm bedded and jointed in mortar as specified (W12B)

H
3500 mm high (B5-B4) 19 m2

I
3500 mm high (B4-B3A) 43 m2

J
3500 mm high (B3A-B3) 50 m2

K
3500 mm high (B3-B2) 22 m2

L
4900 mm high (B2-B1) 25 m2

M
5850 mm high (B1-GF) 25 m2

To Collection

Exterior texture finish as specified (W2)


A
3500 mm high (B5-B4) 262 m2

B
3500 mm high (B4-B3A) 389 m2

C
3500 mm high (B3A-B3) 826 m2

D
3500 mm high (B3-B2) 528 m2

E
3500 mm high (B2-B1) 617 m2

F
5250 mm high (B1-GF) 823 m2

G
3500 mm high (GF-Roof deck) 886 m2

H
to stair #1 (B3A - GF) 218 m2

I
to stair #2 (B4 - GF) 105 m2

J
to stair #3 (B5 - GF) 952 m2

Expose wall plaster as specified (W6)

K
3500 mm high (B5-B4) 372 m2

L
3500 mm high (B4-B3A) 438 m2

M
3500 mm high (B3A-B3) 409 m2

N
3500 mm high (B3-B2) 356 m2

O
3500 mm high (B2-B1) 211 m2

P
5250 mm high (B1-GF) 411 m2

Q
3500 mm high (GF-Roof deck) 184 m2

To Collection

COLLECTION

Page 6/3.4/15 Rp.

Page 6/3.4/16 Rp.

Page 6/3.4/17 Rp.

Page 6/3.4/18 Rp.


SUB BILL NO. 3.4: EXTERNAL ENVELOPE Summary Bill No. 3 Rp.

BILL NO. 3: HOTEL


SUB BILL NO. 3.5: INTERNAL WALLS AND PARTITIONS

Quantity Unit
Code Description

Hebel lightweight concrete blockwall with cement and


sand mortar including reinforced concrete pratical
columns and tie beams

A
Wall, 150 mm wide (hotel unit) 5,898 m2

B
Wall, 100 mm wide (hotel area) (provisional) 994 m2
SUB BILL NO. 3.5: INTERNAL WALLS AND PARTITIONS Summary Bill No. 3 Rp.

BILL NO. 3: HOTEL


SUB BILL NO. 3.6: WALL FINISHES

Quantity Unit
Code Description

Cement and sand (1:3) backing as specified

A
Backing, 25 mm thick to receive interior wall 576 m2

B
Backing, 25 mm thick to receive ceramic tile 62 m2

Prepare and apply paint color : off white ow-4-3 warm


welcome ex.profan (W7) to receive interior wall

C
3500 mm high (B5-B4) 61 m2

D
3500 mm high (B4-B3A) 61 m2

E
3500 mm high (B3A-B3) 61 m2

F
3500 mm high (B3-B2) 60 m2

G
3500 mm high (B2-B1) 130 m2

H
5250 mm high (B1-GF) 132 m2

I
3500 mm high (GF-Roof deck) 71 m2

200x400 mm ceramic tile dpanama perca ex.roman as


specified (W9B)

J
3500 mm high (B5-B4) 9 m2

K
3500 mm high (B4-B3A) 9 m2

L
3500 mm high (B3A-B3) 9 m2
M
1600 mm high (B3-B2) 9 m2

N
4900 mm high (B2-B1) 9 m2

O
5250 mm high (B1-GF) 9 m2

P
3500 mm high (GF-Roof deck) 9 m2

To Collection

Supply and install approved cement liquid


waterproofing system in accordance with the
manufactures instructions as specified

A To bathroom wall 53 m2

Skirting aluminium U channel 20x20 mm as specified

B
To hotel unit 312 m

20 mm thick andesite stone to receive thereshold as


specified

C
To hotel unit 29 m2

Cement and sand (1:3) smooth finish as specified

D
To hotel unit 8,832 m2

Expose wall plaster as specified (W6)

E
To hotel unit 856 m2

To Collection

COLLECTION

Page 6/3.6/21 Rp.

Page 6/3.6/22 Rp.


SUB BILL NO. 3.6: WALL FINISHES Summary Bill No. 3 Rp.

BILL NO. 3: HOTEL


SUB BILL NO. 3.7: FLOOR FINISHES

Quantity Unit
Code Description

Cement and sand (1:3) screed trowelled finish as


specified

A
To floor (B1-B5), polished concrete (F2) 1,547 m2

B
To floor GF, polished concrete (F2) 240 m2

Cement and sand (1:3) screed as specified

C
50 mm thick bed, to receive ceramic tile 226 m2

D
Ditto, to receive thereshold 4 m2

E Backing, 20 mm thick to receive ceramic skirting; 100 215 m


mm high

Ceramic tile ex.Roman finish with grouting, jointed and


pointed as specified

F
Ceramic tile 200 x 200 mm (F4C), to toilet (B1- B5) 15 m2

G
Ceramic tile 400 x 400 mm (F4F), to service (B3 - B5) 66 m2

H
Ditto, to service (B2) 37 m2

I
Ditto, to linen (B2) 7 m2

J
Ditto, to storage (B2) 27 m2

K
Ditto, to pref (B2) 25 m2

L
Ditto, to service (B1) 22 m2

M
Ditto, to storage (B1) 7 m2

N
Ditto, to service (GF) 19 m2

O
Ceramic tile, size 100 mm high to skirting 215 m

To Collection
Prepare and apply cement liquid waterproofing system
in accordance with the manufactures instructions as
specified

A
To toilet floor 15 m2

B
To ramp 1 : 20 (GF) 22 m2

C
To ramp 1 : 10 (B1) 18 m2

D
To ramp 1 : 12 (B2) 40 m2

E
Ditto (B3) 46 m2

F
To ramp 1 : 10 (B3) 14 m2

G
To ramp 1 : 9 (B3A) 25 m2

H
Ditto (B4) 25 m2

Supply and install threshold 4 mm thick steel plat with


anodize finishes

I
To lift & service area (B5 - GF) 4 m2

20 x 20 mm groove line as specified

J To ramp 1 : 20 (GF) 7 m

K To ramp 1 : 12 (B2) 12 m

L Ditto (B3) 37 m

M To ramp 1 : 9 (B3A) 7 m

To Collection

COLLECTION

Page 6/3.7/23 Rp.

Page 6/3.7/24 Rp.


SUB BILL NO. 3.7: FLOOR FINISHES Summary Bill No. 3 Rp.

BILL NO. 3: HOTEL


SUB BILL NO. 3.8: CEILING FINISHES

Quantity Unit
Code Description

Concrete touch up, smooth surface

A
To concrete expose ceiling (B5-GF) 302 m2

9 mm thick calcium silicate board ceiling with


galvanized metal suspension system including shadow
line and all fixing accessories as specified (C2A)

B
Suspended ceiling at lobby lift (B5) 135 m2

C Suspended ceiling at lobby lift & corridor (B4) 247 m2

D Ditto (B3A) 319 m2

E Ditto (B3) 293 m2

F Ditto (B2) 281 m2

G Ditto (B1) 174 m2

H Suspended ceiling at lobby lift (GF) 61 m2


I Ditto at toilet (B1-B5) 17 m2

9 mm thick gysum board ceiling with galvanized metal


suspension system including shadow line and all fixing
accessories as specified (C3)

J Suspended ceiling at service (B3-B5) 66 m2

K Ditto at service (B2) 37 m2

L Ditto at storage (B2) 27 m2

M Ditto at pref (B2) 25 m2

N Ditto at linen (B2) 7 m2

O Ditto at service (B1) 22 m2

P Ditto at storage (B1) 7 m2

Q Ditto at service (GF) 19 m2

To Collection

9.5 mm thick water resistant gypsum as specified (C2)

A To balcony ceiling (hotel unit) 403 m2

Prepare and apply one coat alkali resiting primer, one


coat water based emulsion sealer and two finishing
coats of emulsion paint as specified

B To exposed concrete ceiling surfaces 302 m2

C To calcium silicate board ceiling 1,528 m2

D To gypsum board ceiling 211 m2

E To balcony ceiling (hotel unit) 403 m2


To Collection

COLLECTION

Page 6/3.9/27 Rp.

Page 6/3.9/28 Rp.

SUB BILL NO. 3.8: CEILING FINISHES Summary Bill No. 3 Rp.
BILL NO. 3: HOTEL
SUB BILL NO. 3.9: EXTERNAL WORKS

Quantity Unit
Code Description

Turf and soil as specified at roof garden

A To GF 22 m2

B To B1 96 m2

C To B2 36 m2

D To B3 64 m2

E To B3A 22 m2

Drainage layer as specified at roof garden

F To GF 34 m2

G To B1 36 m2

H To B2 13 m2

I To B3 20 m2

J To B3A 22 m2

Cement and sand (1:3) screed as specified

K
To receive Andesite stone 143 m2

Andesite cover in moss as specified at roof

L To GF 27 m2

M To B2 43 m2

N To B3 72 m2

SUB BILL NO. 3.9: EXTERNAL WORKS Summary Bill No. 3 Rp.
BILL NO. 3: HOTEL
SUB BILL NO. 3.10: MISCELLANEOUS

Quantity Unit
Code Description

Balcony railing

Balcony railing 1000 mm high comprising of solid wood


railings and all fixing accessories

A 100 x 40 mm solid wood handrail (bengkirai) to balcony 854 m

B 60 x 40 mm solid wood horizontal railing support 854 m


(bengkirai) to balcony

Balcony railing 620 mm high comprising of solid wood


railings and all fixing accessories

Bengkirai solid wood ex. Lante kayu as specified to 157 m


C
balcony (hotel unit)

Supply and install solid wood jati doreng as shown on


dwg AR.HA02.102

D
20 mm thick solid wood to receive thereshold 415 m

Ramp railing

Ramp railing 1100 mm high comprising of solid wood


railings and all fixing accessories

E 100 x 40 mm solid wood handrail (bengkirai) to ramp 14 m


1 : 20 (GF)

F Ditto to ramp 1 : 12 (B2) 24 m

G Ditto to ramp 1 : 12 (B3) 74 m

H Ditto to ramp 1 : 9 (B3A) 14 m

I 20 x 60 mm solid wood horizontal railing support 21 m


(bengkirai) ramp 1 : 20 (GF)

J Ditto to ramp 1 : 12 (B2) 35 m

K Ditto to ramp 1 : 12 (B3) 110 m

L Ditto to ramp 1 : 9 (B3A) 22 m

To Collection

Suppy and install M & E works as specified (hotel unit)

A AC grill to inside furniture 194 m

B Socket outlet 690 nos

C MCB to inside furniture 46 nos

D Exhaust fan 138 nos


To Collection

COLLECTION

Page 6/3.10/31 Rp.

Page 6/3.10/32 Rp.


SUB BILL NO. 3.10: MISCELLANEOUS Summary Bill No. 3 Rp.

BILL NO. 3: HOTEL


SUB BILL NO. 3.11: PLUMBING INSTALLATION - HOTEL 15 ROOM A

Quantity Unit
Code Description

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 40 mm diameter Header, with ± 7 m length 1 no

B 80 mm diameter pipework 15 m

C 50 mm diameter , ditto 122 m

D 20 mm diameter, ditto 25 m

E 15 mm diameter, ditto 3 m

Valve and ancillaries including joints to pipeworks

E Tee diameter 80 x 80 x 50 mm 2 no

F 50 mm diameter gate valve 2 no

G 40 mm diameter ditto 4 no

H 32 mm diameter ditto 1 no

I 50 mm diameter water meter 1 no

J 40 mm diameter powered control valve 1 no

K 40 mm diameter check valve 1 no


L 40 mm diameter water mur 1 no

N 15 mm diameter faucet 2 no

Area Toilet (15 Unit)

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

M 25 mm diameter pipework 90 m

N 20 mm diameter ditto 135 m

O 15 mm diameter ditto 240 m

Valve and ancillaries including joints to pipeworks

P 25 mm diameter gate valve 30 no

Q 25 mm diameter water meter 15 no

0.0 COLD WATER SYSTEM To Collection Rp.

HOT WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Head pump 1,2 , Heating capacity 9.6 Kw , rated input 2 unit


power 2.6 Kw /220/1/50Hz, Rated hot water output 140
L/h, Max. water temperatur 55° C, model : WIKA-HPR
9.6-260P, complete with control panel, valve and
accessories.

B Presure hot water tank, capacity 500 L, presurized 4 unit


vertical tank type, inner tank - plate = 2 mm enamel coat,
working presure maximal 4 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model WIKA-500-P. complete with electric
heater,sensor, valve, safety valve, and accessories.

C Circulation Hot water pump (PBAP-03A/B), centrifugal 1 set


end suction type, capacity 100lpm, head 15 m, power
0.5 Kw/220/1/50Hz, pararel altenate, complete with
control panel, valve,header and accessories. (2
units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification
D 40 mm diameter Header, with ± 7 m length 1 no

E 25 mm diameter pipework 52 m

F 20 mm diameter ditto 25 m

G 15 mm diameter ditto 56 m

Valve and ancillaries including joints to pipeworks


(cont'd)
H 20 mm diameter gate valve 1 no
I 20 mm diameter powered control valve 1 no

J 20 mm diameter check valve 1 no

K 20 mm diameter water mur 1 no

0.0 HOT WATER SYSTEM To Collection Rp.

HOT WATER SYSTEM

Area Toilet (15 Unit)

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 20 mm diameter pipework 75 m

B 15 mm diameter ditto 420 m

Valve and ancillaries including joints to pipeworks

C 20 mm diameter gate valve 30 no

D 15 mm diameter ditto 15 no

E 15 mm diameter Check valve 15 no

F 20 mm diameter water meter 15 no

0.0 HOT WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

EQUIPMENT
Supply and install pump units on and including spring
vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Sewage pump (SWP-6A/B), summersible open impeller 1 set


type, capacity 300 lpm, head 20 m, power 7.5
Kw/380/3/50Hz, parallel alternate, non-clog, complete
with control panel valve,floating switches and
accesories (2 units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

B 150 mm diameter, pipework 26 m

C 100 mm diameter, ditto 86 m

Extra over pipework

D Bend 45 degree, 150 mm diameter 2 no

E Ditto, 100 mm diameter 20 no

F Tee diameter 150 x 150 x 100 mm 8 no

G Tee diameter 100 x 100 x 100 mm 8 no

H Tee diameter 100 x 100 x 65 mm 3 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

I 100 mm diameter, pipework 10 m

J 65 mm diameter, ditto 56 m

0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

Extra over pipework (cont'd)

A Bend 90 degree, 100 mm diameter 3 no

B Ditto, 65 mm diameter 2 no

C Tee diameter 100 x 100 x 100 mm 3 no

D Tee diameter 100 x 100 x 65 mm 3 no

E Tee diameter 65 x 65 x 65 mm 20 no

F Bend 45 degree, 65 mm diameter 3 no

G Vent cup 1 no

Area Toilet (15 Unit)


Supply and install Unplasticised Polyvinyl chloride
( uPVC ) pipe, Class D 5 kg/cm2 AW type Class 10
kg/cm2, fixed in position complete with support,
hangers and other necessary fixing and jointing
materials in accordance with the specification

H 100 mm diameter, pipework 30 m

I 80 mm diameter, ditto 45 m

J 65 mm diameter, ditto 90 m

K 50 mm diameter, ditto 45 m

L 40 mm diameter, ditto 75 m

Extra over pipework

M Bend 45 degree, 100 mm diameter 15 no

N Ditto, 80 mm diameter 45 no

O Bend 90 degree, 100 mm diameter 15 no

P Tee diameter 100 x 100 x 100 mm 15 no

Q Tee diameter 100 x 100 x 80 mm 30 no

R Tee diameter 80 x 80 x 50 mm 15 no

S Tee diameter 65 x 65 x 50 mm 30 no

WASTE & DRAIN WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

Extra over pipework (cont'd)

A Tee diameter 65 x 65 x 40 mm 30 no

B Reducer, 80 x 65 mm 15 no

C Ditto, 65 x 50 mm 15 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

D 50 mm diameter, pipework 30 m

E 32 mm diameter, ditto 150 m


0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

Valve and ancillaries including joints to pipeworks

A 200 mm diameter, pipework 30 m

B 150 mm diameter, ditto 15 m

C 100 mm diameter, ditto 164 m

D 80 mm diameter, ditto 50 m

E 65 mm diameter, ditto 18 m

F 50 mm diameter, ditto 116 m

Valve and ancillaries including joints to pipeworks

G Bend 45 degree, 200 mm diameter 3 no

H Ditto, 100 mm diameter 40 no

I Ditto, 80 mm diameter 15 no

J Tee diameter 200 x 200 x 65 mm 1 no

K Tee diameter 150 x 150 x 100 mm 4 no

L Tee diameter 150 x 150 x 80 mm 4 no

M Tee diameter 100 x 100 x 100 mm 10 no

N Tee diameter 100 x 100 x 80 mm 2 no

O Tee diameter 65 x 65 x 50 mm 2 no

P Tee diameter 80 x 80 x 50 mm 3 no

Q 100 mm diameter roof drain 10 no


R 50 mm diameter floor drain 15 no

S Bend 90 degree, 100 mm diameter 5 no

T 100 mm diameter planter drain 8 no

0.00 WASTE & DRAIN WATER SYSTEM To Collection Rp.

ASSOCIATED ELECTRICAL WORK

A Supply and install cable complete with termination, 10 no


splices, tags, conduit and all necessary supporting
accessories

0.0 ASSOCIATED ELECTRICAL WORK To Collection Rp.

Sanitary Fitting
Install the following sanitary fixtures complete with
all necessary fittings and joints to pipework as
specified

Hotel

A WC and eco washer 50 no

B Custom-made terrazzo basin LF-18 100 no

C Washhand basin mixer 100 no

D Bathtub 50 no

E Bathtub mixer 50 no

F Rain shower head, hand shower and thermostatic


mixer 50 no

G Make-up mirror Aliseo 50 no

H Floor outlet 250 no

Back-of-house hotel area

I WC with eco washer 8 no

K Washhand basin 8 no

L Washhand basin mixer 8 no

M Kitchen sink with tapware 8 no

N Floor outlet 16 no

Sanitary Fitting To Collection Rp.

COLLECTION

COLD WATER SYSTEM Rp.

HOT WATER SYSTEM Rp.

HOT WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

ASSOCIATED ELECTRICAL WORK Rp.

Sanitary Fitting Rp.


SUB BILL NO. 3.11: PLUMBING INSTALLATION - HOTEL To Summary Bill No 3 Rp.
15 ROOM A

BILL NO. 3: HOTEL


SUB BILL NO. 3.12: PLUMBING INSTALLATION - HOTEL 15 ROOM B

Quantity Unit
Code Description

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 40 mm diameter Header, with ± 7 m length 1 no

B 50 mm diameter pipework 116 m

C 20 mm diameter, ditto 25 m

Valve and ancillaries including joints to pipeworks

D 50 mm diameter gate valve 2 no

E 40 mm diameter ditto 4 no

F 32 mm diameter ditto 1 no

G 50 mm diameter water meter 1 no

H 40 mm diameter powered control valve 1 no


I 40 mm diameter check valve 1 no

J 40 mm diameter water mur 1 no

Area Toilet (15 Unit)

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

K 25 mm diameter pipework 90 m

L 20 mm diameter ditto 135 m

M 15 mm diameter ditto 240 m

Valve and ancillaries including joints to pipeworks

N 25 mm diameter gate valve 30 no

O 25 mm diameter water meter 15 no

0.0 COLD WATER SYSTEM To Collection Rp.

HOT WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Head pump 1,2 , Heating capacity 9.6 Kw , rated 2 unit


input power 2.6 Kw /220/1/50Hz, Rated hot water
output 140 240 L/h, Max. water temperatur 55° C,
model : WIKA-HPR 9.6-260P, complete with control
panel, valve and accessories.

B Presure hot water tank, capacity 500 L, presurized 4 unit


vertical tank type, inner tank - plate = 2 mm enamel coat,
working presure maximal 4 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model WIKA-500-P. complete with electric
heater,sensor, valve, safety valve, and accessories.

C Circulation Hot water pump (PBAP-03A/B), centrifugal 1 set


end suction type, capacity 100lpm, head 15 m, power
0.5 Kw/220/1/50Hz, pararel altenate, complete with
control panel, valve,header and accessories. (2
units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification
D 40 mm diameter Header, with ± 7 m length 1 no

E 25 mm diameter pipework 52 m

F 20 mm diameter ditto 25 m

G 15 mm diameter ditto 56 m

H 20 mm diameter gate valve 1 no


I 20 mm diameter powered control valve 1 no

J 20 mm diameter check valve 1 no

K 20 mm diameter water mur 1 no

0.0 HOT WATER SYSTEM To Collection Rp.

HOT WATER SYSTEM

Area Toilet (15 Unit)

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 20 mm diameter pipework 75 m

B 15 mm diameter ditto 420 m

Valve and ancillaries including joints to pipeworks

C 20 mm diameter gate valve 30 no

D 15 mm diameter ditto 15 no

E 15 mm diameter Check valve 15 no

F 20 mm diameter water meter 15 no

0.0 HOT WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

EQUIPMENT
Supply and install pump units on and including spring
vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Sewage pump (SWP-5A/B), summersible open impeller 1 set


type, capacity 400 lpm, head 20 m, power 7.5
Kw/380/3/50Hz, parallel alternate, non-clog, complete
with control panel valve,floating switches and
accesories (2 units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

B 150 mm diameter, pipework 26 m

C 100 mm diameter, ditto 106 m

Extra over pipework

D Bend 45 degree, 150 mm diameter 2 no

E Ditto, 100 mm diameter 20 no

F Tee diameter 150 x 150 x 100 mm 8 no

G Tee diameter 100 x 100 x 100 mm 8 no

H Tee diameter 100 x 100 x 65 mm 3 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

I 100 mm diameter, pipework 10 m

J 65 mm diameter, ditto 56 m

0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

Extra over pipework (cont'd)

A Bend 90 degree, 100 mm diameter 3 no

B Ditto, 65 mm diameter 2 no

C Tee diameter 100 x 100 x 100 mm 3 no

D Tee diameter 100 x 100 x 65 mm 3 no

E Tee diameter 65 x 65 x 65 mm 20 no

F Bend 45 degree, 65 mm diameter 3 no

G Vent cup 1 no
Area Toilet (15 Unit)

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2 AW type Class 10
kg/cm2, fixed in position complete with support,
hangers and other necessary fixing and jointing
materials in accordance with the specification

H 100 mm diameter, pipework 30 m

I 80 mm diameter, ditto 45 m

J 65 mm diameter, ditto 90 m

K 50 mm diameter, ditto 45 m

L 40 mm diameter, ditto 75 m

Extra over pipework

M Bend 45 degree, 100 mm diameter 15 no

N Ditto, 80 mm diameter 45 no

O Bend 90 degree, 100 mm diameter 15 no

P Tee diameter 100 x 100 x 100 mm 15 no

Q Tee diameter 100 x 100 x 80 mm 30 no

R Tee diameter 80 x 80 x 50 mm 15 no

S Tee diameter 65 x 65 x 50 mm 30 no

0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

Extra over pipework (cont'd)

A Tee diameter 65 x 65 x 40 mm 30 no

B Reducer, 80 x 65 mm 15 no

C Ditto, 65 x 50 mm 15 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

D 50 mm diameter, pipework 30 m

E 32 mm diameter, ditto 150 m


0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

Valve and ancillaries including joints to pipeworks

A 200 mm diameter, pipework 30 m

B 150 mm diameter, ditto 15 m

C 100 mm diameter, ditto 120 m

D 80 mm diameter, ditto 50 m

E 65 mm diameter, ditto 18 m

F 50 mm diameter, ditto 116 m

Valve and ancillaries including joints to pipeworks

G Bend 45 degree, 200 mm diameter 3 no

H Ditto, 100 mm diameter 32 no

I Ditto, 80 mm diameter 15 no

J Tee diameter 200 x 200 x 65 mm 1 no

K Tee diameter 150 x 150 x 100 mm 4 no

L Tee diameter 150 x 150 x 80 mm 4 no

M Tee diameter 100 x 100 x 100 mm 5 no

N Tee diameter 100 x 100 x 80 mm 2 no

O Tee diameter 65 x 65 x 50 mm 2 no
P Tee diameter 80 x 80 x 50 mm 3 no

Q 100 mm diameter roof drain 10 no

R 50 mm diameter floor drain 15 no

0.00 WASTE & DRAIN WATER SYSTEM To Collection Rp.

ASSOCIATED ELECTRICAL WORK

A Supply and install cable complete with termination, 10 no


splices, tags, conduit and all necessary supporting
accessories

0.0 ASSOCIATED ELECTRICAL WORK To Collection Rp.

COLLECTION
COLD WATER SYSTEM Rp.

HOT WATER SYSTEM Rp.

HOT WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

WASTE & DRAIN WATER SYSTEM Rp.

ASSOCIATED ELECTRICAL WORK Rp.

SUB BILL NO. 3.12: PLUMBING INSTALLATION - HOTEL To Summary Bill No 3 Rp.
15 ROOM B

BILL NO. 3: HOTEL


SUB BILL NO. 3.13: PLUMBING INSTALLATION - HOTEL 12 ROOM

Quantity Unit
Code Description

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 25 mm diameter Header, with ± 7 m length 1 no


B 50 mm diameter pipework 136 m

C 20 mm diameter ditto 21 m

Valve and ancillaries including joints to pipeworks

D 50 mm diameter gate valve 2 no

E 40 mm diameter ditto 2 no

F 25 mm diameter ditto 2 no

G 50 mm diameter water meter 1 no

H 25 mm diameter powered control valve 1 no

I 25 mm diameter check valve 1 no

J 25 mm diameter water mur 1 no

Area Toilet (12 Unit)

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

K 25 mm diameter pipework 72 m

L 20 mm diameter ditto 108 m

M 15 mm diameter ditto 192 m

Valve and ancillaries including joints to pipeworks

N 25 mm diameter gate valve 24 no

O 25 mm diameter water meter 12 no

0.0 COLD WATER SYSTEM To Collection Rp.

HOT WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Head pump 1 , Heating capacity 4.8 Kw , rated input 1 unt


power 2.6 1.3 Kw /220/1/50Hz, Rated hot water output
140 120 L/h, Max. water temperatur 55° C, model :
WIKA-HPR 9.6 4.8-260 130P, complete with control
panel, valve and accessories.

B Head pump 2 , Heating capacity 9.6 Kw , rated input 1 unt


power 1.3 2.6 Kw /220/1/50Hz, Rated hot water output
120 240 L/h, Max. water temperatur 55° C, model :
WIKA-HPR 4.8 9.6-130 260P, complete with control
panel, valve and accessories.
C Presure hot water tank, capacity 500 L, presurized 3 unt
vertical tank type, inner tank - plate = 2 mm enamel coat,
working presure maximal 4 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model WIKA-500-P. complete with electric
heater,sensor, valve, safety valve, and accessories.

D Circulation Hot water pump (PBAP-02A/B), centrifugal 1 set


end suction type, capacity 100lpm, head 15 m, power
0.5 Kw/220/1/50Hz, pararel altenate, complete with
control panel, valve,header and accessories. (2
units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification
E 25 mm diameter Header, with ± 7 m length 1 no

F 25 mm diameter pipework 40 m

G 20 mm diameter ditto 21 m

H 15 mm diameter ditto 44 m

0.0 HOT WATER SYSTEM To Collection Rp.

HOT WATER SYSTEM

Valve and ancillaries including joints to pipeworks


(cont'd)

A 20 mm diameter gate valve 3 no

B 20 mm diameter powered control valve 1 no

C 20 mm diameter check valve 1 no

D 20 mm diameter water mur 1 no

Area Toilet (12 Unit)

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

E 20 mm diameter pipework 60 m

F 15 mm diameter ditto 336 m

Valve and ancillaries including joints to pipeworks

G 20 mm diameter gate valve 24 no

H 15 mm diameter ditto 12 no

I 15 mm diameter Check valve 12 no

J 20 mm diameter water meter 12 no


0.0 HOT WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Sewage pump (SWP-4A/B), summersible open 1 set


impeller type, capacity 400 300 lpm, head 20 m, power
7.5 Kw/380/3/50Hz, parallel alternate, non-clog,
complete with control panel valve,floating switches
and accesories (2 units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

B 100 mm diameter, pipework 184 m

Extra over pipework

C Bend 90 degree, 100 mm diameter 17 no

D Bend 45 degree, 100 mm diameter 22 no

E Tee diameter 100 x 100 x 100 mm 4 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

F 100 mm diameter, pipework 8 m

G 65 mm diameter, ditto 44 m

0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.


WASTE & DRAIN WATER SYSTEM

Extra over pipework (cont'd)

A Bend 90 degree, 100 mm diameter 2 no

B Ditto, 65 mm diameter 2 no

C Tee diameter 100 x 100 x 100 mm 2 no

D Tee diameter 100 x 100 x 65 mm 2 no

E Tee diameter 65 x 65 x 65 mm 16 no

F Bend 45 degree, 65 mm diameter 2 no

G Vent cup 1 no

Area Toilet (12 Unit)

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

H 100 mm diameter, pipework 24 m

I 80 mm diameter, ditto 36 m

J 65 mm diameter, ditto 72 m

K 50 mm diameter, ditto 36 m

L 40 mm diameter, ditto 60 m

Extra over pipework

M Bend 45 degree, 100 mm diameter 12 no

N Ditto, 80 mm diameter 36 no

O Bend 90 degree, 100 mm diameter 12 no

P Tee diameter 100 x 100 x 100 mm 12 no

Q Tee diameter 100 x 100 x 80 mm 24 no

R Tee diameter 80 x 80 x 50 mm 12 no

S Tee diameter 65 x 65 x 50 mm 24 no

0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

Extra over pipework (cont'd)

A Tee diameter 65 x 65 x 40 mm 24 no

B Reducer, 80 x 65 mm 12 no

C Ditto, 65 x 50 mm 12 no

VENT PIPEWORK
Supply and install Unplasticised Polyvinyl chloride
( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

D 50 mm diameter, pipework 24 m

E 32 mm diameter, ditto 120 m

0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

A 150 mm diameter, pipework 40 m

B 100 mm diameter, ditto 40 m

C 80 mm diameter, ditto 40 m

D 65 mm diameter, ditto 55 m

E 50 mm diameter, ditto 85 m

Valve and ancillaries including joints to pipeworks

F Bend 45 degree, 150 mm diameter 2 no

G Ditto, 100 mm diameter 4 no

H Ditto, 80 mm diameter 12 no
I Ditto, 65 mm diameter 24 no

J Tee diameter 150 x 150 x 100 mm 4 no

K Tee diameter 150 x 150 x 80 mm 4 no

L Tee diameter 100 x 100 x 65 mm 4 no

M Tee diameter 65 x 65 x 50 mm 4 no

N 100 mm diameter roof drain 8 no

O 50 mm diameter floor drain 12 no

RAIN WATER SYSTEM To Collection Rp.

ASSOCIATED ELECTRICAL WORK

A Supply and install cable complete with termination, 10 no


splices, tags, conduit and all necessary supporting
accessories
0.0 ASSOCIATED ELECTRICAL WORK To Collection Rp.

COLLECTION

COLD WATER SYSTEM

HOT WATER SYSTEM

HOT WATER SYSTEM

WASTE & DRAIN WATER SYSTEM

WASTE & DRAIN WATER SYSTEM

WASTE & DRAIN WATER SYSTEM

RAIN WATER SYSTEM

ASSOCIATED ELECTRICAL WORK

SUB BILL NO. 3.13: PLUMBING INSTALLATION - HOTEL To Summary Bill No 3 Rp.
12 ROOM
BILL NO. 3: HOTEL
SUB BILL NO. 3.14: PLUMBING INSTALLATIONS - HOTEL 8 ROOM

Quantity Unit
Code Description

COLD WATER SYSTEM

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 25 mm diameter Header, with ± 7 m length 1 no

B 50 mm diameter pipework 67 m

C 20 mm diameter ditto 18 m

Valve and ancillaries including joints to pipeworks

D 50 mm diameter gate valve 2 no

E 40 mm diameter ditto 2 no

F 25 mm diameter ditto 2 no

G 50 mm diameter water meter 1 no

H 25 mm diameter powered control valve 1 no

I 25 mm diameter check valve 1 no

J 25 mm diameter water mur 1 no

Area Toilet (8 Unit)

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

K 25 mm diameter pipework 48 m

L 20 mm diameter ditto 72 m

M 15 mm diameter ditto 128 m

Valve and ancillaries including joints to pipeworks

N 25 mm diameter gate valve 16 no

O 25 mm diameter water meter 8 no

COLD WATER SYSTEM To Collection Rp.

HOT WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :
A Head pump 1 & 2 , Heating capacity 4.8 Kw , rated 2 unit
input power 2.6 Kw /220/1/50Hz, Rated hot water
output 140 120 L/h, Max. water temperatur 55° C,
model : WIKA-HPR 9.6 4.8-260 130P, complete with
control panel, valve and accessories.

B Presure hot water tank, capacity 500 L, presurized 2 unit


vertical tank type, inner tank - plate = 2 mm enamel coat,
working presure maximal 4 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model WIKA-500-P. complete with electric
heater,sensor, valve, safety valve, and accessories.

C Circulation Hot water pump (PBAP-01A/B), centrifugal 1 set


end suction type, capacity 100lpm, head 10 m, power
0.4 Kw/220/1/50Hz, pararel altenate, complete with
control panel, valve,header and accessories. (2
units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification
D 25 mm diameter Header, with ± 7 m length 1 no

E 25 mm diameter pipework 36 m

F 20 mm diameter ditto 18 m

G 15 mm diameter ditto 40 m

H 20 mm diameter gate valve 3 no

I 20 mm diameter powered control valve 1 no

J 20 mm diameter check valve 1 no

K 20 mm diameter water mur 1 no

HOT WATER SYSTEM To Collection Sub Bill 2.5 Rp.

HOT WATER SYSTEM

Area Toilet (8 Unit)

PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 20 mm diameter pipework 60 m

B 15 mm diameter ditto 336 m

Valve and ancillaries including joints to pipeworks

C 20 mm diameter gate valve 16 no

D 15 mm diameter ditto 8 no

E 15 mm diameter Check valve 8 no

F 20 mm diameter water meter 8 no


HOT WATER SYSTEM To Collection Sub Bill 2.5 Rp.

WASTE & DRAIN WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Sewage pump (SWP-2A/B), summersible open 1 set


impeller type, capacity 25 200 lpm, head 25 m, power
7.5 Kw/380/3/50Hz, parallel alternate, non-clog,
complete with control panel valve,floating switches
and accesories (2 units/set)

RISER & DISTRIBUTION PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

B 150 mm diameter, pipework 11 m

C 100 mm diameter, ditto 150 m

Extra over pipework

D Bend 90 degree, 150 mm diameter 2 no

E Bend 90 degree, 100 mm diameter 1 no

F Bend 45 degree, 100 mm diameter 6 no

G Tee diameter 150 x 150 x 100 mm 1 no

H Tee diameter 100 x 100 x 100 mm 8 no

I Tee diameter 100 x 100 x 80 mm 8 no

VENT PIPEWORK
Supply and install Unplasticised Polyvinyl chloride
( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

J 100 mm diameter, pipework 4 m

K 65 mm diameter, ditto 37 m

0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.

WASTE & DRAIN WATER SYSTEM

Extra over pipework (cont'd)

A Bend 90 degree, 100 mm diameter 2 no

B Ditto, 65 mm diameter 2 no

C Tee diameter 100 x 100 x 100 mm 2 no

D Tee diameter 100 x 100 x 65 mm 2 no

E Tee diameter 65 x 65 x 65 mm 11 no

F Bend 45 degree, 65 mm diameter 2 no

G Vent cup 1 no

Area Toilet (8 Unit)

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2 AW type Class 10
kg/cm2, fixed in position complete with support,
hangers and other necessary fixing and jointing
materials in accordance with the specification

H 100 mm diameter, pipework 16 m

I 80 mm diameter, ditto 24 m

J 65 mm diameter, ditto 48 m

K 50 mm diameter, ditto 24 m

L 40 mm diameter, ditto 40 m

Extra over pipework

M Bend 45 degree, 100 mm diameter 8 no

N Ditto, 80 mm diameter 24 no

O Bend 90 degree, 100 mm diameter 8 no

P Tee diameter 100 x 100 x 100 mm 8 no

Q Tee diameter 100 x 100 x 80 mm 16 no

R Tee diameter 80 x 80 x 50 mm 8 no

S Tee diameter 65 x 65 x 50 mm 16 no

0.0 WASTE & DRAIN WATER SYSTEM To Collection Rp.


WASTE & DRAIN WATER SYSTEM

Extra over pipework (cont'd)

A Tee diameter 65 x 65 x 40 mm 16 no

B Reducer, 80 x 65 mm 8 no

C Ditto, 65 x 50 mm 8 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

D 50 mm diameter, pipework 16 m

E 32 mm diameter, ditto 80 m

WASTE & DRAIN WATER SYSTEM To Collection Rp.

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

A 150 mm diameter, pipework 40 m

B 100 mm diameter, ditto 40 m

C 80 mm diameter, ditto 40 m
D 65 mm diameter, ditto 55 m

E 50 mm diameter, ditto 45 m

Valve and ancillaries including joints to pipeworks

F Bend 45 degree, 150 mm diameter 2 no

G Ditto, 100 mm diameter 4 no

H Ditto, 80 mm diameter 8 no

I Ditto, 65 mm diameter 24 no

J Tee diameter 150 x 150 x 100 mm 4 no

K Tee diameter 150 x 150 x 80 mm 4 no

L Tee diameter 100 x 100 x 65 mm 4 no

M Tee diameter 65 x 65 x 50 mm 4 no

N 100 mm diameter roof drain 8 no

O 50 mm diameter floor drain 8 no

RAIN WATER SYSTEM To Collection Rp.

ASSOCIATED ELECTRICAL WORK

A Supply and install cable complete with termination, 10 no


splices, tags, conduit and all necessary supporting
accessories
0.0 ASSOCIATED ELECTRICAL WORK To Collection Rp.

COLLECTION

COLD WATER SYSTEM

HOT WATER SYSTEM

HOT WATER SYSTEM

WASTE & DRAIN WATER SYSTEM

WASTE & DRAIN WATER SYSTEM

WASTE & DRAIN WATER SYSTEM

RAIN WATER SYSTEM

ASSOCIATED ELECTRICAL WORK


SUB BILL NO. 3.14: PLUMBING INSTALLATIONS - HOTEL To Summary Bill No 3 Rp.
8 ROOM

BILL NO. 3: HOTEL


SUMMARY

Quantity Unit
Code Description

SUMMARY BILL 3

SUB BILL NO. 3.1: SUB STRUCTURE

SUB BILL NO. 3.2: UPPER STRUCTURE

SUB BILL NO. 3.3: STAIR FINISHES

SUB BILL NO. 3.4: EXTERNAL ENVELOPE

SUB BILL NO. 3.5: INTERNAL WALLS AND


PARTITIONS

SUB BILL NO. 3.6: WALL FINISHES

SUB BILL NO. 3.7: FLOOR FINISHES

SUB BILL NO. 3.8: CEILING FINISHES

SUB BILL NO. 3.9: EXTERNAL WORKS

SUB BILL NO. 3.10: MISCELLANEOUS

SUB BILL NO. 3.11: PLUMBING INSTALLATION -


HOTEL 15 ROOM A

SUB BILL NO. 3.12: PLUMBING INSTALLATION -


HOTEL 15 ROOM B

SUB BILL NO. 3.13: PLUMBING INSTALLATION -


HOTEL 12 ROOM

SUB BILL NO. 3.14: PLUMBING INSTALLATIONS -


HOTEL 8 ROOM

SUMMARY NO. 3 : HOTEL Summary Bill No. 3 Rp.


BILL NO. 4: ONE BEDROOM VILLA - FLAT ROOF
SUB BILL NO. 4.1: SUB STRUCTURE
ORIGINAL

Code Description Quantity Unit

SUB STRUCTURE

General

A Allow for providing all plant and equipment on site for ls


the installation of the piles including moving the plant
and equipment about the site, the provision of
temporary supports as required during the execution of
the works and for removing the plant and equipment
from site on completion of the works

B Allow for submission of records in triplicate of all bored ls


piles installed, duly signed by the Contractor and
deliver to the Project Manager as the work proceeds

C Allow for the submission of a drawing showing the final ls


plan position of each pile reference by a serial number
and the levels of the bottom and top of each pile as
installed

Bored Tension Piles

Note:
Bored pile, 300mm diameter ( …. no)

D Boring, 300mm diameter from bottom level pile cap to m


proposed bored pile level (6 m)

E Install temporary caison / liner as necessary and no


subsequently remove

F Concrete filling (K-300), to 300mm diameter pile (6 m) m3

G General reinforcing bar 13 mm diameter kg

H General reinforcing bar 8 mm diameter kg

I Remove surplus excavated material/soil disposal from m3


site
Page 6/Sub bill 4.1/1 To Collection

Pile Testing

A Allow for providing and mobilizing all necessary ls


equipment, materials and labour to carry out axial and
lateral load tests

B Carry out axial compression load test on 300mm no


diameter pile (PDA Test Dinamis)

C Carry out lateral load test on 300mm diameter pile no

D Carry out PIT test on working pile size 300mm no


diameter ramdomly

E Clean up and remove load testing equipment from site ls


on completion of the load testing works

F Allow for recording results and providing reports as ls


specified
Page 6/Sub bill 4.1/2 To Collection

Excavation

Note: The quantities given are the net volume,


allowance for additional excavation to provide working
space shall be included in the unit rates

A Excavation not exceeding 1.5 m deep commencing 21 m3


from existing level

B Backfilling with selected excavated material 10 m3

C Remove surplus excavated material from site 11 m3

Temporary dewatering

D Allow for providing a temporary dewatering system 1 ls


during the excavation process as required

Anti termite

E Apply anti termite to excavated surface area as 1 ls


specified

Compacted sand bed

F Compacted sand, 100mm thick under footing 17 m2

G Ditto, under tie beams 5 m2

H Ditto, under ground slab 28 m2

Lean concrete

I Lean concrete, 50mm thick under footing 17 m2


J Ditto, under tie beams 5 m2

K Ditto, under ground slab 28 m2

Page 6/Sub bill 4.1/3 To Collection

Vibrated reinforced concrete grade K-300

B To footing 4 m3

C To tie beams 2 m3

D To ground slab 1 m3

E To ground slab edge 240mm high 1 m3

F To stump column 1 m3

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables

G General reinforcing bars in footing, 16mm diameter 259 kg

H ditto, 13mm diameter 627 kg

I ditto, 8mm diameter 17 kg

J General reinforcing bars in tie beams, 13mm diameter 209 kg

K ditto, 10mm diameter 142 kg


L General reinforcing bars in ground slab edge 150 kg
(Provisional)

M General reinforcing bars in stump column (Provisional ) 150 kg

L General reinforcing bars in tie beams; 16mm diameter 400 kg

M Ditto; 13mm diameter kg

N Stirrups in tie beams 10 mm diameter kg

O General reinforcing bars in basement slabs; 10mm 150 kg


diameter

Page 6/Sub bill 4.1/4 To Collection

Wiremesh M5 (1 layer) including joint anchor, as


specified

A to ground slab 28 m2

Supply and install formwork as specified

B To sides of footing 16 m2

C To edges of tie beams 21 m2

D To edges of slab 50mm high 31 m

E To ground slab edge 240mm high 9 m

F To stump column 8 m2
Page 6/Sub bill 4.1/5 To Collection

COLLECTION

Page 6/Sub bill 4.1/1 Rp.

Page 6/Sub bill 4.1/2 Rp.


Page 6/Sub bill 4.1/3 Rp.

Page 6/Sub bill 4.1/4 Rp.

Page 6/Sub bill 4.1/5 Rp.

SUB BILL NO. 4.1: SUB STRUCTURE Summary Bill No. 4 Rp.
BILL NO. 4: ONE BEDROOM VILLA - FLAT ROOF
SUB BILL NO. 4.2: UPPER STRUCTURE

Code Description Quantity Unit

UPPER STRUCTURE

Vibrated reinforced concrete grade K-300

A Columns 6 m3

B Beams (Provisional) 11 m3

C Ring beams (Provisional) 5 m3

D Roof slab 14 m3

E Roof gutter 1 m3

F Slab above pump room 8 m3

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables

G General reinforcing bars in columns (Provisional) 1,800 kg

H Stirrups in columns (Provisional) kg

I General reinforcing bars in beam, 19mm diameter 356 kg


(Provisional)

J ditto, 16mm diameter (prov) 1,213 kg

K Stirrups in beam, 10mm diameter (prov) 675 kg

L General reinforcing bars in ring beam, 16mm diameter 747 kg


(Provisional)

M ditto, 13mm diameter (Provisional) 110 kg

N Stirrups in ring beam, 10mm diameter (Provisional) 328 kg


P General reinforcing bars in concrete gutter 150 kg
(Provisional)

Page 6/Sub bill 4.2/5 To Collection

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables (Cont'd)

A General reinforcing bars in roof slab (Provisional) 2,100 kg

B General reinforcing bars in roof gutter (Provisional) 150 kg

C General reinforcing bars in slab above pump room, 1,315 kg


10mm diameter (Provisional)

Supply and install formwork as specified

D To sides of columns 60 m2

E To sides and soffit of beam 111 m2

F To sides and soffit of ring beam 72 m2

G To soffit of roof slab 134 m2

H To sides and soffit of roof gutter 27 m2

I To soffit of Slab above pump room 82 m2


Page 6/Sub bill 4.2/6 To Collection

PLUNGE POOL AND PUMP ROOM

Vibrated reinforced concrete grade K-250

A
Pool slab 5 m3

B
Pool wall 5 m3

C
Pool gutter 5 m3

D
Pump room & balancing tank slab 2 m3

E
Pump room & balancing tank wall (Provisional) 2 m3
Supply and install bar reinforcement; deform steel
BJTP 24 ,BJTD 40 including bending, cutting to
length and supplying and installing all tying wire,
accessories and consumables

F
General reinforcing bars in pool slab, 13mm diameter 549 kg

G General reinforcing bars in pool wall, 13mm diameter 735 kg

H General reinforcing bars in pool gutter, 13mm 494 kg


diameter
I General reinforcing bars in Pump room & balancing 188 kg
tank slab, 10mm diameter

J General reinforcing bars in Pump room & balancing kg


tank wall, 10mm diameter (Provisional)

Supply and install formwork as specified

K
To soffit of slab 19 m2

L
To edges of slab 250mm high 23 m

M
To sides of pool wall and gutter 98 m2

N
To sides of pump room and balancing tank slab 17 m2

O To sides of pump room and balancing tank wall 25 m2


(Provisional)

Page 6/Sub bill 4.2/7 To Collection

COLLECTION

Page 6/Sub bill 4.2/5 Rp.

Page 6/Sub bill 4.2/6 Rp.


Page 6/Sub bill 4.2/7 Rp.
SUB BILL NO. 4.2: UPPER STRUCTURE Summary Bill No. 4 Rp.

BILL NO. 4: ONE BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 4.3: ROOF COVERING

Code Description Quantity Unit

Supply and install approved waterproofing system in


accordance with the manufactures instructions as
specified

A To concrete roof slab 144 m2

B To concrete gutter size 200 x 303mm 25 m

30 mm thick protective cement and sand (1:5) screed


laid to falls over waterproof membrane to roof as
specified

C To concrete roof slab 144 m2

D To concrete gutter size 200 x 303mm 25 m

Supply and install 25 mm thick spray polyurethane


foam roof insulation as specified

E
Roof insulation 144 m2

Supply and install 20mm thick concrete wood panel


fascia complete with 4 mm thick steel plate cover and
all necessary fixing accessoris

F
Solid wood fascia U shape 150 x 200 mm 48 m

Andesite stone plank size 300 x 280mm and 20mm


thick bedded and jointed in mortar as specified

G
To roof slab 144 m2

Supply and install cast iron roof outlet complete


with all necessary fixing accessoris
H
Roof drain 2 no

SUB BILL NO. 4.3: ROOF COVERING Summary Bill No. 4 Rp.

0
SUB BILL NO. 4.4: EXTERNAL ENVELOPE

Code Description Quantity Unit

Hebel block walls with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A To walls, 150mm thick 176 m2

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish ex. Mortar
Utama

B
To walls, 25 mm thick 205 m2

Texture paint ex. Lemkra Stone Paint applied strictly


according to the manufacturer instructions

C Texture wall paint finish 205 m2


Jati Doreng Timber Screens complete with frames and
all fixing accessories

D
Timber screen overall size 1100 x 3200mm high 1 no

Page 6/Sub bill 4.4/10 To Collection

DOORS AND WINDOWS

Doors
Supply and install aluminum doors, complete with
aluminum frames and jambs, 8mm thick clear glass
leaf door, main track system for sliding door,
hardwares as specified and all fixing accessories

A Double sliding door and double fixed panel, overall 1 no


size 4400 x 2550mm at Living Room (D01)

B Double sliding door and double fixed panel, overall 1 no


size 4650 x 2550mm at Bedroom (D02)

Supply and install engineered wood doors, complete


with solid timber frames, solid timber jambs, hardwares
as specified and all fixing accessories

C Double swing door, overall size 1100 x 2550mm at 1 no


Main Entrance (D04)

Steel door with steel plate frame and 9 mm thick


calcium silicate board and textured paint finish
complete with hardwares and all necessary
accessories as specified

D Single pivot door, overall size 550 x 1500mm at Dry 1 no


Garden (D05)

Windows

E
Fixed glass window, 10mm thick tempered clear glass, 1 no
overall size 2650 x 2400mm high complete with all
fixing accessories (W01)

F
Fixed glass window, 10mm thick tempered clear glass, 1 no
overall size 460 x 1220mm high complete with all fixing
accessories (W02)

G
Pivot glass window, 10mm thick tempered clear glass, 1 no
overall size 1100 x 1620mm high complete with
hardwares and all fixing accessories (W03)

To Collection
COLLECTION

Page 6/Sub bill 4.4/10 Rp.

Page 6/Sub bill 4.4/11 Rp.


SUB BILL NO. 4.4: EXTERNAL ENVELOPE Summary Bill No. 4 Rp.

BILL NO. 4: ONE BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 4.5: INTERNAL WALLS AND PARTITIONS

Quantity Unit
Code Description

Hebel block walls with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A 47 m2
To walls, 100mm thick

B To walls, double cavity walls 300 mm wide surround 13 m2


pocket sliding door
SUB BILL NO. 4.5: INTERNAL WALLS AND PARTITIONS Summary Bill No. 4 Rp.

BILL NO. 4: ONE BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 4.6: FLOOR FINISHES

Code Description Quantity Unit

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

A To bathroom floor 12 m2
SUB BILL NO. 4.6: FLOOR FINISHES Summary Bill No. 4 Rp.

0
SUB BILL NO. 4.7: WALL FINISHES

Code Description Quantity Unit

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish

A m2
To walls, 25 mm thick 91

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

B To bathroom wall 19 m2
SUB BILL NO. 4.7: WALL FINISHES Summary Bill No. 4 Rp.

BILL NO. 4: ONE BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 4.8: CEILING FINISHES

Code Description Quantity Unit

Lambrisering ceiling on and including 40 x 40 mm


hollow steel suspension system including joints,
shadow line and all fixing accessories as specified

A
Suspended ceiling external 82 m2

B m2
Suspended ceiling internal

9,5 mm thick water resistant gypsum board ceiling ex.


USG Boral with concealed suspension system
including 25 mm shadow line and all fixing accessories
as specified

B Suspended ceiling at bathroom m2

C Suspended ceiling at basement 81 m2

Prepare and apply one coat alkali resiting primer, one


coat water based emulsion sealer and two finishing
coats of emulsion paint as specified

D Paint calcium silicate board ceiling 81 m2


SUB BILL NO. 4.8: CEILING FINISHES Summary Bill No. 4 Rp.

BILL NO. 4: ONE BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 4.9: PLUMBING INSTALLATIONS

Quantity Unit
Code Description

COLD WATER SYSTEM

PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification
A 25 mm diameter pipework 19 m

B 20 mm diameter ditto 23 m

C 15 mm diameter ditto 47 m

Valve and ancillaries including joints to pipeworks

D 20 mm diameter gate valve 2 no

E 20 mm diameter floating valve 2 no


Page 6/Sub bill 4.9/17 To Collection

HOT WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Head pump, Heating capacity 2.7 Kw , rated input 1 unit


power 0.6 Kw /220/1/50Hz, Rated hot water output 90
L/h, Max. water temperatur 55° C, model : HPU 2.7-060
P, complete with control panel, valve and all
accessories.

B Presure hot water tank, capacity 300 L, presurized 1 unit


vertical tank type, inner tank - enamel t, working
presure maximal 5 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model PT - 300 L . complete with sensor,
valve, safety valve, and all accessories.

PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

C 20mm diameter pipework 44 m

D 15 mm diameter ditto 34 m
Page 6/Sub bill 4.9/18 To Collection

WASTE & DRAIN WATER SYSTEM

EQUIPMENT

Supply and install septictank package (Biotek) and


including all necessary supporting accessories as
required in accordance with the specifications,
drawings and manufacturer's instructions as described

A Septitank package ( Biotek) with capacity 1 m3 2 set


complete with all accessories

B Portable Grease trap 2 set

PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

C 100 mm diameter, pipework 26 m

D 80 mm diameter, ditto 9 m

E 65 mm diameter, ditto 11 m

F 40 mm diameter, ditto 15 m

G 32 mm diameter, ditto 15 m
Page 6/Sub bill 4.9/19 To Collection

WASTE & DRAIN WATER SYSTEM (Cont'd)

Extra over pipework

A Bend 90 degree, 100 mm diameter 4 no

B Bend 90 degree, 65 mm diameter 8 no

C Bend 45 degree, 100 mm diameter 8 no

D Bend 45 degree, 80 mm diameter 4 no

E Bend 45 degree, 65 mm diameter 9 no

F Tee diameter 100 x 100 x 80 mm 2 no

G Tee diameter 100 x 100 x 40 mm 2 no

H Tee diameter 80 x 80 x 65 mm 6 no

I Tee diameter 80 x 80 x 32 mm 4 no

VENT PIPEWORK
Supply and install Unplasticised Polyvinyl chloride
(uPVC) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

J 50 mm diameter, pipework 11 m

Valve and ancillaries including joints to pipeworks

K Vent cup 2 no

Page 6/Sub bill 4.9/20 To Collection

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

A 100 mm diameter, pipework 53 m

Extra over pipework

B Bend 90 degree, 100 mm diameter 4 no

C Bend 45 degree, 100 mm diameter 8 no


D Tee diameter 100 x 100 x 100 mm 2 no

Valve and ancillaries including joints to pipeworks

E 100 mm diameter roof drain 4 no

Page 6/Sub bill 4.9/21 To Collection

ASSOCIATED ELECTRICAL WORK

A Supply and install cable complete with termination, 2 no


splices, tags, conduit and all necessary supporting
accessories
Page 6/Sub bill 4.9/22 To Collection

Sanitary Fitting

Install the following sanitary fixtures complete with


all necessary fittings and joints to pipework as
specified

A WC and eco washer 1 no

B Custom-made terrazzo basin LF-18 2 no

C Washhand basin mixer 2 no

D Custom-made terrazzo bathtub LF-19 1 no

E Bathtub mixer 1 no

F Rain shower head, hand shower and thermostatic


mixer 1 no

G Floor outlet 3 no

H Pantry sink and tapware 1 no


Sanitary Fitting To Collection

COLLECTION

Page 6/Sub bill 4.9/17 Rp.

Page 6/Sub bill 4.9/18 Rp.

Page 6/Sub bill 4.9/19 Rp.

Page 6/Sub bill 4.9/20 Rp.

Page 6/Sub bill 4.9/21 Rp.

Page 6/Sub bill 4.9/22 Rp.

Sanitary Fitting Rp.


SUB BILL NO. 4.9: PLUMBING INSTALLATIONS Summary Bill No. 4 Rp.

BILL NO. 4: ONE BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 4.10: EXTERNAL WORKS

Code Description Quantity Unit

GATE AND GARDEN WALL

Local red brick wall with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A To external walls, 150mm thick (Provisional) 35 m2

Paras Kerobokan stone bedded and jointed in mortar


as specified

B To external walls, 150mm thick (Provisional) 35 m2

Bangkirai wood plank size 180x3000x15mm complete


with all fixing accessories

C To external walls finishes at Main Entry 5 m2


Decorative column including blockwork, Andesit stone
tiles 20mm thick surface finishes as specified

D Decorative column size 360 x 250mm and 3250mm 2 no


high at Main Entry

Decorative wall incuding blockworks, carved stone,


andesit stone tiles 20mm thick as specified

E Decorative wall 10 m2

CANOPY AT PATHWAY

F Canopy overall size 3630 x 2925mm comprising of 1 ls


10mm thick tempered clear glass, 40x40mm wood
framescomplete with all necessary fixing accessories

Page 6/Sub bill 4.10/24 To Collection

0.00 POOL DECK

Supply and install Bangkirai solid wood deck size


20x90mm and full length ex. Lante Kayu complete with
required joists, backings and all fixing accessories to
strictly follow manufacture instructions

A Pool Deck 7 m2
0.00 POOL

Mozaic tiles size 75x75mm ex. Wisma Sehati bedded


and jointed in mortar

B To pool wall finishes 24 m2

C To pool floor finishes 16 m2

D To pool treads, 300mm wide 2 m

E To pool risers, 75mm high 1 m

F To pool risers, 225mm high 2 m

G Ditto but 280mm high 1 m

Andesit stone bedded and jointed in mortar as


specified

H To pool skirting size 20x120x300mm, 120mm high 24 m

I To pool gutter 14mm thick complete with shadow lines 15 m2

Lemkra Stone Paint rough plaster applied strictly


according to the manufacturer instructions

J Texture wall paint finish 23 m2

Waterprrofing coating as specified

K Waterproofing coating to pool and gutter area 77 m2

Page 6/Sub bill 4.10/25 To Collection


BALANCING AND PUMP ROOM

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish ex. Mortar
Utama

A
To walls, 25 mm thick 44 m2

Floor hardener ex. Flowcrete as specified

B
To floor finishes 15 m2

Steel door as specified

C Steel door to pump room overall size 980 x 2000mm 1 no


Page 6/Sub bill 4.10/26 To Collection

COLLECTION

Page 6/Sub bill 4.10/24 Rp.

Page 6/Sub bill 4.10/25 Rp.

Page 6/Sub bill 4.10/26 Rp.


SUB BILL NO. 4.10: EXTERNAL WORKS Summary Bill No. 4 Rp.

BILL NO. 4: ONE BEDROOM VILLA - FLAT ROOF

Code Description Quantity Unit

SUMMARY

SUB BILL NO. 4.1: SUB STRUCTURE

SUB BILL NO. 4.2: UPPER STRUCTURE

SUB BILL NO. 4.3: ROOF COVERING

SUB BILL NO. 4.4: EXTERNAL ENVELOPE

SUB BILL NO. 4.5: INTERNAL WALLS AND


PARTITIONS

SUB BILL NO. 4.6: FLOOR FINISHES

SUB BILL NO. 4.7: WALL FINISHES


SUB BILL NO. 4.8: CEILING FINISHES

SUB BILL NO. 4.9: PLUMBING INSTALLATIONS

SUB BILL NO. 4.10: EXTERNAL WORKS

TOTAL 1 UNIT ONE BEDROOM VILLA - FLAT ROOF

TOTAL 9 UNIT ONE BEDROOM VILLA - FLAT ROOF

SUMMARY NO. 4: ONE BEDROOM VILLA - FLAT


To Final Summary
ROOF
BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF
SUB BILL NO. 5.1: SUB STRUCTURE
ORIGINAL

Code Description Quantity Unit

SUB STRUCTURE

General

A Allow for providing all plant and equipment on site for ls


the installation of the piles including moving the plant
and equipment about the site, the provision of
temporary supports as required during the execution of
the works and for removing the plant and equipment
from site on completion of the works

B Allow for submission of records in triplicate of all bored ls


piles installed, duly signed by the Contractor and
deliver to the Project Manager as the work proceeds

C Allow for the submission of a drawing showing the final ls


plan position of each pile reference by a serial number
and the levels of the bottom and top of each pile as
installed

Bored Tension Piles

Note:
Bored pile, 300mm diameter ( …. no)

D Boring, 300mm diameter from bottom level pile cap to m


proposed bored pile level (6 m)

E Install temporary caison / liner as necessary and no


subsequently remove

F Concrete filling (K-300), to 300mm diameter pile (6 m) m3

G General reinforcing bar 13 mm diameter kg

H General reinforcing bar 8 mm diameter kg

I Remove surplus excavated material/soil disposal from m3


site
Page 6/Sub bill 5.1/1 To Collection

Pile Testing

A Allow for providing and mobilizing all necessary ls


equipment, materials and labour to carry out axial and
lateral load tests

B Carry out axial compression load test on 300mm no


diameter pile (PDA Test Dinamis)

C Carry out lateral load test on 300mm diameter pile no

D Carry out PIT test on working pile size 300mm no


diameter ramdomly

E Clean up and remove load testing equipment from site ls


on completion of the load testing works

F Allow for recording results and providing reports as ls


specified
Page 6/Sub bill 5.1/2 To Collection

Excavation

Note: The quantities given are the net volume,


allowance for additional excavation to provide working
space shall be included in the unit rates

A Excavation not exceeding 1.5 m deep commencing 21 m3


from existing level

B Backfilling with selected excavated material 10 m3

C Remove surplus excavated material from site 11 m3

Temporary dewatering

D Allow for providing a temporary dewatering system 1 ls


during the excavation process including retribution to
the government

Anti termite

E Apply anti termite to excavated surface area as 1 ls


specified

Compacted sand bed

F Compacted sand, 100mm thick under footing 17 m2

G Ditto, under tie beams 5 m2

H Ditto, under ground slab 1 m2

Lean concrete

I Lean concrete, 50mm thick under footing 17 m2

J Ditto, under tie beams 5 m2

K Ditto, under ground slab 29 m2


Page 6/Sub bill 5.1/3 To Collection

Vibrated reinforced concrete grade K-300

A To footing 4 m3

B To tie beams 2 m3

C To ground slab 1 m3

D To ground slab edge 240mm high 1 m3

E To stump column 1 m3

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables

F General reinforcing bars in footing, 16mm diameter 259 kg

G ditto, 13mm diameter 627 kg

H ditto, 8mm diameter 17 kg

I General reinforcing bars in tie beams, 13mm diameter 209 kg

J ditto, 10mm diameter 142 kg

K General reinforcing bars in ground slab edge 150 kg


(Provisional)

L General reinforcing bars in stump column (Provisional) 200 kg


Page 6/Sub bill 5.1/4 To Collection

Wiremesh M5 (1 layer) including joint anchor, as


specified

A to ground slab 28 m2

Supply and install formwork as specified

B To sides of footing 16 m2

C To side of tie beams 21 m2

D To edges of slab 50mm high 31 m

E To ground slab edge 240mm high 9 m

F To stump column 8 m2
Page 6/Sub bill 5.1/5 To Collection

COLLECTION

Page 6/Sub bill 5.1/1 Rp.

Page 6/Sub bill 5.1/2 Rp.

Page 6/Sub bill 5.1/3 Rp.

Page 6/Sub bill 5.1/4 Rp.

Page 6/Sub bill 5.1/5 Rp.


SUB BILL NO. 5.1: SUB STRUCTURE Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 5.2: UPPER STRUCTURE

Code Description Quantity Unit

UPPER STRUCTURE
Vibrated reinforced concrete grade K-300

A Columns 6 m3

B Beams (Provisional) 11 m3

C Ring beams (Provisional) 5 m3

D Slab above pump room 8 m3

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables

E General reinforcing bars in columns (Provisional) 1,800 kg

F Stirrups in columns (Provisional) kg

G General reinforcing bars in beam, 19mm diameter 356 kg


(Provisional)

H ditto, 16mm diameter (Provisional) 1,214 kg

I Stirrups in beam, 10mm diameter (Provisional) 675 kg

J General reinforcing bars in ring beam, 16mm diameter 813 kg


(Provisional)

K ditto, 13mm diameter (Provisional) 44 kg

L Stirrups in ring beam, 10mm diameter (Provisional) 291 kg

M General reinforcing bars in slab above pump room, 1,315 kg


10mm diameter

O Ditto; 10mm diameter kg

P General reinforcing bars in concrete gutter (provisional) 150 kg


Page 6/Sub bill 5.2/5 To Collection

Supply and install formwork as specified

A To sides of columns 60 m2

B To sides and soffit of beam 111 m2

C To sides and soffit of ring beam 63 m2

D To soffit of Slab above pump room 82 m2


Page 6/Sub bill 5.2/6 To Collection

PLUNGE POOL AND PUMP ROOM

Vibrated reinforced concrete grade K-250

A
Pool slab 5 m3

B
Pool wall 5 m3

C
Pool gutter 5 m3

D
Pump room & balancing tank slab 2 m3

E
Pump room & balancing tank wall (Provisional) 2 m3

Supply and install bar reinforcement; deform steel


BJTP 24 ,BJTD 40 including bending, cutting to
length and supplying and installing all tying wire,
accessories and consumables

F
General reinforcing bars in pool slab, 13mm diameter 549 kg

G General reinforcing bars in pool wall, 13mm diameter 735 kg

H General reinforcing bars in pool gutter, 13mm diameter 494 kg

I General reinforcing bars in Pump room & balancing 188 kg


tank slab, 10mm diameter

J General reinforcing bars in Pump room & balancing 800 kg


tank wall, 10mm diameter (Provisional)

Supply and install formwork as specified

K
To soffit of slab 19 m2
L
To edges of slab 250mm high 23 m

M To sides of pool wall and gutter 98 m2

N To sides of pump room and balancing tank slab 17 m2

O To sides of pump room and balancing tank wall 25 m2


(Provisional)

Page 6/Sub bill 5.2/7 To Collection

COLLECTION

Page 6/Sub bill 5.2/5 Rp.

Page 6/Sub bill 5.2/6 Rp.

Page 6/Sub bill 5.2/7 Rp.


SUB BILL NO. 5.2: UPPER STRUCTURE Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 5.3: ROOF COVERING

Code Description Quantity Unit

ROOF STEEL STRUCTURE

Supply and and install roof steel structure including


cutting, fabricating, assembling, welding, connections,
surface treatment prior to erection, fixing in place and
all necessary fixings and accessories

A WF 200x100x5.5x8 1,045 kg

B WF 150x75x5x7 146 kg

C 2-L 50x50x5 65 kg
D CNP 125x50x20x3.2 604 kg

E Trekstang - Ø12 mm 34 kg

F Wind bracing - D 16mm 88 kg

G 10mm thick Plate, bolt, embeded and stiffeners 1 ls

I Anchor Bolt M16 x 300mm length 16 no

Paint Finishes

J Epoxy/ Marine Paint 2,071 kg

Page 6/Sub bill 5.3/9 To Collection

ROOFING
Concrete wood panel size 20x3000mm and 14mm
thick on and including hollow steel 40x40mm framings,
angle bar complete with all fixings and installed in
accordance with the manufactures instructions

A
Timber plank roofing 114 m2

B
Ridge 10 m

Roof insulation comprising of metal deck,


waterproofing membrane, 12mm thick multiplex
complete with all necessary fixing accessories as
specified
C
Insulation to pitched roof 114 m2

Flashing zinc 3 mm thick complete with all fixings

D
Flashing 10 m

Roof gutter to pitch roof comprising of timber frames,


mortar screed, 4mm thick flashing zinc and
waterproofing

E
Roof gutter size 200 x 210mm 20 m

Supply and install approved waterproofing system in


accordance with the manufactures instructions as
specified

F To concrete roof slab 5 m2

30 mm thick protective cement and sand (1:5) screed


laid to falls over waterproof membrane to roof as
specified

G To concrete roof slab 5 m2

Supply and install cast iron roof outlet complete with all
necessary fixing accessoris

Andesite stone plank size 300 x 280mm and 20mm


thick bedded and jointed in mortar as specified

H To roof slab 5 m2

Supply and install cast iron roof outlet complete with all
necessary fixing accessoris

H
Roof drain 2 no
Page 6/Sub bill 5.3/10 To Collection

0.00 ROOFING (Cont'd)

Supply and install 25 mm thick solid wood fascia


complete with 4 mm thick steel plate cover and all
necessary fixing accessoris

A
Solid wood fascia 300 mm wide 41 m
Page 6/Sub bill 5.3/11 To Collection

COLLECTION

Page 6/Sub bill 5.3/9 Rp.

Page 6/Sub bill 5.3/10 Rp.

Page 6/Sub bill 5.3/11 Rp.


SUB BILL NO. 5.3: ROOF COVERING Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 5.4: EXTERNAL ENVELOPE

Code Description Quantity Unit

Hebel block walls with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A To walls, 150mm thick 185 m2

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish ex. Mortar
Utama

B
To walls, 25 mm thick 214 m2

Texture paint ex. Lemkra Stone Paint applied strictly


according to the manufacturer instructions
C Texture wall paint finish 214 m2

Jati Doreng Timber Screens complete with frames and


all fixing accessories

D
Timber screen overall size 1100 x 3200mm high 1 no

Page 6/Sub bill 5.4/13 To Collection

DOORS AND WINDOWS

Doors
Supply and install aluminum doors, complete with
aluminum frames and jambs, 8mm thick clear glass
leaf door, main track system for sliding door,
hardwares as specified and all fixing accessories

A Double sliding door and double fixed panel, overall 1 no


size 4400 x 2550mm at Living Room (D01)

B Double sliding door and double fixed panel, overall 1 no


size 4650 x 2550mm at Bedroom (D02)

Supply and install engineered wood doors, complete


with solid timber frames, solid timber jambs, hardwares
as specified and all fixing accessories

C Double swing door, overall size 1100 x 2550mm at 1 no


Main Entrance (D04)

Steel door with steel plate frame and 9 mm thick


calcium silicate board and textured paint finish
complete with hardwares and all necessary
accessories as specified

D Single pivot door, overall size 550 x 1500mm at Dry 1 no


Garden (D05)

Windows

E
Fixed glass window, 10mm thick tempered clear glass, 1 no
overall size 2650 x 2400mm high complete with all
fixing accessories (W01)

F
Fixed glass window, 10mm thick tempered clear glass, 1 no
overall size 460 x 1220mm high complete with all fixing
accessories (W02)

G
Pivot glass window, 10mm thick tempered clear glass, 1 no
overall size 1100 x 1620mm high complete with
hardwares and all fixing accessories (W03)

Page 6/Sub bill 5.4/14 To Collection

COLLECTION
Page 6/Sub bill 5.4/13 Rp.

Page 6/Sub bill 5.4/14 Rp.


SUB BILL NO. 5.4: EXTERNAL ENVELOPE Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 5.5: INTERNAL WALLS AND PARTITIONS

Quantity Unit
Code Description

Hebel block walls with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A
To walls, 100mm thick 49 m2

B To walls, double cavity walls 300 mm wide surround 15 m2


pocket sliding door
SUB BILL NO. 5.5: INTERNAL WALLS AND PARTITIONS Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 5.6: FLOOR FINISHES

Code Description Quantity Unit

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

A To bathroom floor 12 m2
SUB BILL NO. 5.6: FLOOR FINISHES Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 5.7: WALL FINISHES

Code Description Quantity Unit


15 mm thick plaster comprising 12 mm thick premixed
dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish

A
To walls, 25 mm thick 91 m2

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

B To bathroom wall 19 m2
SUB BILL NO. 5.7: WALL FINISHES Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 5.8: CEILING FINISHES

Code Description Quantity Unit

Lambrisering ceiling on and including 40 x 40 mm


hollow steel suspension system including joints,
shadow line and all fixing accessories as specified

A
Suspended ceiling external 31 m2

B
Suspended ceiling internal m2

9,5 mm thick water resistant gypsum board ceiling ex.


USG Boral with concealed suspension system
including 25 mm shadow line and all fixing accessories
as specified

B Suspended ceiling at bathroom m2

C Suspended ceiling at basement 81 m2

Prepare and apply one coat alkali resiting primer, one


coat water based emulsion sealer and two finishing
coats of emulsion paint as specified

D Paint calcium silicate board ceiling 81 m2


SUB BILL NO. 5.8: CEILING FINISHES Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 5.9: PLUMBING INSTALLATIONS

Code Description Quantity Unit

COLD WATER SYSTEM

PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 25 mm diameter pipework 18 m

B 20 mm diameter ditto 22 m

C 15 mm diameter ditto 46 m

Valve and ancillaries including joints to pipeworks

D 20 mm diameter gate valve 2 no


E 20 mm diameter floating valve 2 no

Page 6/Sub bill 5.9/20 To Collection

HOT WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :
A Head pump, Heating capacity 2.7 Kw , rated input 1 unit
power 0.6 Kw /220/1/50Hz, Rated hot water output 90
L/h, Max. water temperatur 55° C, model : HPU 2.7-
060 P, complete with control panel, valve and all
accessories.

B Presure hot water tank, capacity 300 L, presurized 1 unit


vertical tank type, inner tank - enamel t, working
presure maximal 5 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model PT - 300 L . complete with sensor,
valve, safety valve, and all accessories.

PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

C 20mm diameter pipework 39 m

D 15 mm diameter ditto 33 m

Page 6/Sub bill 5.9/21 To Collection

WASTE & DRAIN WATER SYSTEM

EQUIPMENT
Supply and install septictank package (Biotek) and
including all necessary supporting accessories as
required in accordance with the specifications,
drawings and manufacturer's instructions as described

A Septitank package ( Biotek) with capacity 1 m3 2 set


complete with all accessories

B Portable Grease trap 2 set

PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

C 100 mm diameter, pipework 26 m

D 80 mm diameter, ditto 9 m

E 65 mm diameter, ditto 11 m

F 40 mm diameter, ditto 15 m

G 32 mm diameter, ditto 15 m
Page 6/Sub bill 5.9/22 To Collection

WASTE & DRAIN WATER SYSTEM (Cont'd)

Extra over pipework

A Bend 90 degree, 100 mm diameter 4 no

B Bend 90 degree, 65 mm diameter 7 no

C Bend 45 degree, 100 mm diameter 7 no

D Bend 45 degree, 80 mm diameter 4 no

E Bend 45 degree, 65 mm diameter 9 no

F Tee diameter 100 x 100 x 80 mm 2 no

G Tee diameter 100 x 100 x 40 mm 2 no

H Tee diameter 80 x 80 x 65 mm 6 no

I Tee diameter 80 x 80 x 32 mm 4 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

J 50 mm diameter, pipework 11 m

Valve and ancillaries including joints to pipeworks

K Vent cup 2 no
Page 6/Sub bill 5.9/23 To Collection

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

A 100 mm diameter, pipework 52 m

Extra over pipework

B Bend 90 degree, 100 mm diameter 4 no

C Bend 45 degree, 100 mm diameter 7 no

D Tee diameter 100 x 100 x 100 mm 2 no

Valve and ancillaries including joints to pipeworks

E 100 mm diameter roof drain 4 no


Page 6/Sub bill 5.9/24 To Collection

ASSOCIATED ELECTRICAL WORK

A Supply and install cable complete with termination, 2 no


splices, tags, conduit and all necessary supporting
accessories
Page 6/Sub bill 5.9/25 To Collection

COLLECTION

Page 6/Sub bill 5.9/20 Rp.

Page 6/Sub bill 5.9/21 Rp.

Page 6/Sub bill 5.9/22 Rp.

Page 6/Sub bill 5.9/23 Rp.

Page 6/Sub bill 5.9/24 Rp.

Page 6/Sub bill 5.9/25 Rp.


SUB BILL NO. 5.9: PLUMBING INSTALLATIONS Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 5.10: EXTERNAL WORKS

Code Description Quantity Unit

GATE AND GARDEN WALL


Local red brick wall with cement and sand (1:2),
including reinforced concrete practical columns and tie
beams

A To external walls, 150mm thick (Provisional) 35 m2

Paras Kerobokan stone bedded and jointed in mortar


as specified

B To external walls, 150mm thick (Provisional) 35 m2

Bangkirai wood plank size 180x3000x15mm complete


with all fixing accessories

C To external walls finishes at Main Entry 5 m2

Decorative column including blockwork, Andesit stone


tiles 20mm thick surface finishes as specified

D Decorative column size 360 x 250mm and 3250mm 2 no


high at Main Entry

Decorative wall incuding blockworks, carved stone,


andesit stone tiles 20mm thick as specified

E Decorative wall 10 m2

CANOPY AT PATHWAY

F Canopy overall size 3630 x 2925mm comprising of 1 ls


10mm thick tempered clear glass, 40x40mm wood
framescomplete with all necessary fixing accessories
Page 6/Sub bill 5.10/27 To Collection

0.00 POOL DECK

Supply and install Bangkirai solid wood deck size


20x90mm and full length ex. Lante Kayu complete with
required joists, backings and all fixing accessories to
strictly follow manufacture instructions

A Pool Deck 7 m2

0.00 POOL

Mozaic tiles size 75x75mm ex. Wisma Sehati bedded


and jointed in mortar

B To pool wall finishes 24 m2

C To pool floor finishes 16 m2

D To pool treads, 300mm wide 2 m

E To pool risers, 75mm high 1 m

F To pool risers, 225mm high 2 m

G Ditto but 280mm high 1 m

Andesit stone bedded and jointed in mortar as specified

H To pool skirting size 20x120x300mm, 120mm high 24 m

I To pool gutter 14mm thick complete with shadow lines 15 m2

Lemkra Stone Paint rough plaster applied strictly


according to the manufacturer instructions

J Texture wall paint finish 23 m2

Waterprrofing coating as specified

K Waterproofing coating to pool and gutter area 77 m2


Page 6/Sub bill 5.10/28 To Collection

BALANCING AND PUMP ROOM

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish ex. Mortar
Utama

A
To walls, 25 mm thick 44 m2

Floor hardener ex. Flowcrete as specified

B
To floor finishes 15 m2

Steel door as specified

C Steel door to pump room overall size 980 x 2000mm 1 no


Page 6/Sub bill 5.10/29 To Collection

COLLECTION

Page 6/Sub bill 5.10/27 Rp.

Page 6/Sub bill 5.10/28 Rp.

Page 6/Sub bill 5.10/29 Rp.


SUB BILL NO. 5.10: EXTERNAL WORKS Summary Bill No. 5 Rp.

BILL NO. 5: ONE BEDROOM VILLA - PITCH ROOF

Code Description Quantity Unit

SUMMARY

SUB BILL NO. 5.1: SUB STRUCTURE

SUB BILL NO. 5.2: UPPER STRUCTURE

SUB BILL NO. 5.3: ROOF COVERING


SUB BILL NO. 5.4: EXTERNAL ENVELOPE

SUB BILL NO. 5.5: INTERNAL WALLS AND


PARTITIONS

SUB BILL NO. 5.6: FLOOR FINISHES

SUB BILL NO. 5.7: WALL FINISHES

SUB BILL NO. 5.8: CEILING FINISHES

SUB BILL NO. 5.9: PLUMBING INSTALLATIONS

SUB BILL NO. 5.10: EXTERNAL WORKS

TOTAL 1 UNIT ONE BEDROOM VILLA - PITCH


ROOF

TOTAL 19 UNIT ONE BEDROOM VILLA - PITCH


ROOF

SUMMARY NO. 5: ONE BEDROOM VILLA - PITCH ROOF To Final Summary


BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF
SUB BILL NO. 6.1: SUB STRUCTURE
ORIGINAL

Code Description Quantity Unit

SUB STRUCTURE

General

A Allow for providing all plant and equipment on site for ls


the installation of the piles including moving the plant
and equipment about the site, the provision of
temporary supports as required during the execution of
the works and for removing the plant and equipment
from site on completion of the works

B Allow for submission of records in triplicate of all bored ls


piles installed, duly signed by the Contractor and
deliver to the Project Manager as the work proceeds

C Allow for the submission of a drawing showing the final ls


plan position of each pile reference by a serial number
and the levels of the bottom and top of each pile as
installed

Bored Tension Piles

Note:
Bored pile, 300mm diameter ( …. no)

D Boring, 300mm diameter from bottom level pile cap to m


proposed bored pile level (6 m)

E Install temporary caison / liner as necessary and no


subsequently remove

F Concrete filling (K-300), to 300mm diameter pile (6 m) m3

G General reinforcing bar 13 mm diameter kg

H General reinforcing bar 8 mm diameter kg

I Remove surplus excavated material/soil disposal from m3


site
Page 6/Sub bill 6.1/1 To Collection Rp.

Pile Testing

A Allow for providing and mobilizing all necessary ls


equipment, materials and labour to carry out axial and
lateral load tests

B Carry out axial compression load test on 300mm no


diameter pile (PDA Test Dinamis)

C Carry out lateral load test on 300mm diameter pile no

D Carry out PIT test on working pile size 300mm no


diameter ramdomly

E Clean up and remove load testing equipment from site ls


on completion of the load testing works

F Allow for recording results and providing reports as ls


specified
Page 6/Sub bill 6.1/2 To Collection Rp.

Excavation

Note: The quantities given are the net volume,


allowance for additional excavation to provide working
space shall be included in the unit rates

A Excavation not exceeding 1.5 m deep commencing 35 m3


from existing level

B Backfilling with selected excavated material 18 m3

C Remove surplus excavated material from site 17 m3

Temporary dewatering

D Allow for providing a temporary dewatering system 1 ls


during the excavation process as required

Anti termite

E Apply anti termite to excavated surface area as 1 ls


specified

Compacted sand bed

F Compacted sand, 100mm thick under footing 29 m2

G Ditto, under tie beams 8 m2

H Ditto, under ground slab 46 m2


Lean concrete

I Lean concrete, 50mm thick under footing 29 m2

J Ditto, under tie beams 8 m2

K Ditto, under ground slab 46 m2

Page 6/Sub bill 6.1/3 To Collection

Prepare and apply damp proof polythene sheet as


specified

A To undersides of ground slab and tie beams 54 m2

Vibrated reinforced concrete grade K-300

B To pile caps 8 m3

C To tie beams 3 m3

D To ground slab 2 m3

E To ground slab edge 240mm high 1 m3

F To stump column 1 m3

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables
G General reinforcing bars in pile caps, 16mm diameter 758 kg

H ditto, 13mm diameter 881 kg

I ditto, 8mm diameter 34 kg

J General reinforcing bars in tie beams, 13mm diameter 305 kg

K ditto, 10mm diameter 196 kg

L General reinforcing bars in ground slab edge , 13mm 150 kg


diameter (Provisional)

M ditto, 10mm diameter (Provisional) kg

N General reinforcing bars in stump column (Provisional) 150 kg

Page 6/Sub bill 6.1/4 To Collection

Wiremesh M5 (1 layer) including joint anchor, as


specified

A to ground slab 44 m2

Supply and install formwork as specified

B To sides of pile caps 25 m2

C To edges of tie beams 28 m2

D To edges of slab 50mm high 47 m


E To ground slab edge 240mm high 14 m

F To stump column 11 m2

Page 6/Sub bill 6.1/5 To Collection


COLLECTION

Page 6/Sub bill 6.1/1 Rp.

Page 6/Sub bill 6.1/2 Rp.

Page 6/Sub bill 6.1/3 Rp.

Page 6/Sub bill 6.1/4 Rp.

Page 6/Sub bill 6.1/5 Rp.


SUB BILL NO. 6.1: SUB STRUCTURE Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 6.2: UPPER STRUCTURE

Code Description Quantity Unit

UPPER STRUCTURE

Vibrated reinforced concrete grade K-300

A Columns 8 m3

B Beams (Provisional) 13 m3

C Ring beams (Provisional) 12 m3

D Roof slab 25 m3

E Roof gutter 1 m3

F Slab above pump room 16 m3

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables

G General reinforcing bars in columns (Provisional) 2,400 kg

H Stirrups in columns kg
I General reinforcing bars in beam, 19mm diameter 437 kg
(Provisional)

J ditto, 16mm diameter (Provisional) 1,393 kg

K Stirrups in beam, 10mm diameter (Provisional) 713 kg

L General reinforcing bars in ring beam, 25mm diameter 111 kg


(Provisional)

M ditto, 19mm diameter (Provisional) 531 kg

N ditto, 16mm diameter (Provisional) 699 kg

O ditto, 13mm diameter (Provisional) 246 kg

P Stirrups in ring beam, 10mm diameter (Provisional) 754 kg

Page 6/Sub bill 6.2/5 To Collection

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables (Cont'd)

A General reinforcing bars in roof slab (Provisional) 3,750 kg

B General reinforcing bars in roof gutter (Provisional) 150 kg

C General reinforcing bars in slab above pump room, 2,011 kg


10mm diameter

Supply and install formwork as specified

D To sides of columns 85 m2
E To sides and soffit of beam (Provisional) 122 m2

F To sides and soffit of ring beam (Provisional) 134 m2

G To soffit of roof slab (Provisional) 167 m2

H To sides and soffit of roof gutter (Provisional) 27 m2

I To soffit of slab above pump room (Provisional) 105 m2

Page 6/Sub bill 6.2/6 To Collection

PLUNGE POOL AND PUMP ROOM

Vibrated reinforced concrete grade K-250

A
Pool slab 7 m3
B
Pool wall 7 m3

C
Pool gutter 8 m3

D
Pump room & balancing tank slab (Provisional) 2 m3

E
Pump room & balancing tank wall (Provisional) m3

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables

F
General reinforcing bars in pool slab, 13mm diameter 782 kg

G General reinforcing bars in pool wall, 13mm diameter 1,060 kg

H General reinforcing bars in pool gutter, 13mm 717 kg


diameter
I General reinforcing bars in Pump room & balancing 244 kg
tank slab, 10mm diameter

J General reinforcing bars in Pump room & balancing kg


tank wall, 10mm diameter (Provisional)

Supply and install formwork as specified

K
To soffit of slab 26 m2

L
To edges of slab 250mm high 32 m

M To sides of pool wall and gutter 148 m2

N To sides of pump room and balancing tank slab 18 m2

O To sides of pump room and balancing tank wall m2


(Provisional)
Page 6/Sub bill 6.2/7 To Collection

COLLECTION

Page 6/Sub bill 6.2/5 Rp.

Page 6/Sub bill 6.2/6 Rp.

Page 6/Sub bill 6.2/7 Rp.


SUB BILL NO. 6.2: UPPER STRUCTURE Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 6.3: ROOF COVERING

Code Description Quantity Unit

Supply and install approved waterproofing system in


accordance with the manufactures instructions as
specified

A To concrete roof slab 201 m2

B To concrete gutter size 200 x 303mm 34 m

30 mm thick protective cement and sand (1:5) screed


laid to falls over waterproof membrane to roof as
specified

C To concrete roof slab 201 m2

D To concrete gutter size 200 x 303mm 34 m

Supply and install 25 mm thick spray polyurethane


foam roof insulation as specified

E
Roof insulation 201 m2
Supply and install 20mm thick concrete wood panel
fascia complete with 4 mm thick steel plate cover and
all necessary fixing accessoris

F
Solid wood fascia U shape 150 x 200 mm 58 m

Andesite stone plank size 300 x 280mm and 20mm


thick bedded and jointed in mortar as specified

H To roof slab 201 m2

Supply and install cast iron roof outlet complete


with all necessary fixing accessoris

H Roof drain 2 no

SUB BILL NO. 6.3: ROOF COVERING Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 6.4: EXTERNAL ENVELOPE

Code Description Quantity Unit

Hebel block walls with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams
A To walls, 150mm thick 209 m2

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish ex. Mortar
Utama

B
To walls, 25 mm thick 252 m2

Texture paint ex. Lemkra Stone Paint applied strictly


according to the manufacturer instructions

C Texture wall paint finish 252 m2

Jati Doreng Timber Screens complete with frames and


all fixing accessories

D
Timber screen overall size 1100 x 3200mm high 2 no
Page 6/Sub bill 6.4/10 To Collection

DOORS AND WINDOWS

Doors

Supply and install aluminum doors, complete with


aluminum frames and jambs, 8mm thick clear glass
leaf door, main track system for sliding door,
hardwares as specified and all fixing accessories

A Double sliding door and double fixed panel, overall 2 no


size 4650 x 2550mm at Bedroom (D02)

B Double sliding door and double fixed panel, overall 1 no


size 4400 x 2550mm at Bedroom (D03)

Supply and install engineered wood doors, complete


with solid timber frames, solid timber jambs, hardwares
as specified and all fixing accessories

C Double swing door, overall size 1100 x 2550mm at 1 no


Main Entrance (D04)

Steel door with steel plate frame and 9 mm thick


calcium silicate board and textured paint finish
complete with hardwares and all necessary
accessories as specified

D Single pivot door, overall size 550 x 1500mm at Dry 2 no


Garden (D05)

Windows

E
Fixed glass window, 10mm thick tempered clear glass, 2 no
overall size 2650 x 2400mm high complete with all
fixing accessories (W01)
F
Fixed glass window, 10mm thick tempered clear glass, 2 no
overall size 460 x 1220mm high complete with all fixing
accessories (W02)

s
Pivot glass window, 10mm thick tempered clear glass, 2 no
overall size 1100 x 1620mm high complete with
hardwares and all fixing accessories (W03)

Page 6/Sub bill 6.4/11 To Collection

COLLECTION

Page 6/Sub bill 6.4/10 Rp.

Page 6/Sub bill 6.4/11 Rp.


SUB BILL NO. 6.4: EXTERNAL ENVELOPE Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 6.5: INTERNAL WALLS AND PARTITIONS

Quantity Unit
Code Description

Hebel block walls with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A
To walls, 100mm thick 88 m2

B To walls, double cavity walls 300 mm wide surround 25 m2


pocket sliding door
SUB BILL NO. 6.5: INTERNAL WALLS AND PARTITIONS Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 6.6: FLOOR FINISHES

Code Description Quantity Unit

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

A To bathroom floor 24 m2
SUB BILL NO. 6.6: FLOOR FINISHES Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 6.7: WALL FINISHES

Code Description Quantity Unit

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish

A
To walls, 25 mm thick 139 m2

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

B To bathroom wall 39 m2
SUB BILL NO. 6.7: WALL FINISHES Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 6.8: CEILING FINISHES
Code Description Quantity Unit

Lambrisering ceiling on and including 40 x 40 mm


hollow steel suspension system including joints,
shadow line and all fixing accessories as specified

A
Suspended ceiling external 102 m2

B
Suspended ceiling internal m2

9,5 mm thick water resistant gypsum board ceiling ex.


USG Boral with concealed suspension system
including 25 mm shadow line and all fixing accessories
as specified

B Suspended ceiling at bathroom m2

C Suspended ceiling at basement 125 m2

Prepare and apply one coat alkali resiting primer, one


coat water based emulsion sealer and two finishing
coats of emulsion paint as specified

D Paint calcium silicate board ceiling 125 m2


SUB BILL NO. 6.8: CEILING FINISHES Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 6.9: PLUMBING INSTALLATIONS

Code Description Quantity Unit

COLD WATER SYSTEM

PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 32 mm diameter pipework 4 m

B 25 mm diameter ditto 14 m

C 20 mm diameter ditto 18 m

D 15 mm diameter ditto 60 m

Valve and ancillaries including joints to pipeworks

E 20 mm diameter gate valve 1 no

F 20 mm diameter floating valve 1 no


Page 6/Sub bill 6.9/17 To Collection

HOT WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Head pump, Heating capacity 2.7 Kw , rated input 1 unit


power 0.6 Kw /220/1/50Hz, Rated hot water output 90
L/h, Max. water temperatur 55° C, model : HPU 2.7-
060 P, complete with control panel, valve and all
accessories.
B Presure hot water tank, capacity 300 L, presurized 1 unit
vertical tank type, inner tank - enamel t, working
presure maximal 5 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model PT - 300 L . complete with sensor,
valve, safety valve, and all accessories.

PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

C 20mm diameter pipework 28 m

D 15 mm diameter ditto 36 m

Page 6/Sub bill 6.9/18 To Collection

WASTE & DRAIN WATER SYSTEM

EQUIPMENT
Supply and install septictank package (Biotek) and
including all necessary supporting accessories as
required in accordance with the specifications,
drawings and manufacturer's instructions as described

A Septitank package ( Biotek) with capacity 1.5 m3 1 set


complete with all accessories

B Portable Grease trap 1 set

PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


(uPVC) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

C 100 mm diameter, pipework 40 m

D 80 mm diameter, ditto 5 m

E 65 mm diameter, ditto 12 m

F 40 mm diameter, ditto 4 m

G 32 mm diameter, ditto 12 m
Page 6/Sub bill 6.9/19 To Collection

WASTE & DRAIN WATER SYSTEM (Cont'd)

Extra over pipework

A Bend 90 degree, 100 mm diameter 3 no

B Bend 90 degree, 65 mm diameter 8 no

C Bend 45 degree, 100 mm diameter 4 no

D Bend 45 degree, 65 mm diameter 10 no

E Tee diameter 100 x 100 x 100 mm 4 no

F Tee diameter 100 x 100 x 65 mm 4 no

G Tee diameter 100 x 100 x 32 mm 4 no

H Tee diameter 80 x 80 x 65 mm 2 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

I 50 mm diameter, pipework 6 m

32 mm diameter, ditto 12 m

Valve and ancillaries including joints to pipeworks

J Vent cup 2 no
Page 6/Sub bill 6.9/20 To Collection

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

A 100 mm diameter, pipework 57 m

Extra over pipework

B Bend 90 degree, 100 mm diameter 6 no

C Bend 45 degree, 100 mm diameter 10 no

D Tee diameter 100 x 100 x 100 mm 2 no

Valve and ancillaries including joints to pipeworks

E 100 mm diameter roof drain 4 no


Page 6/Sub bill 6.9/21 To Collection

ASSOCIATED ELECTRICAL WORK

A Supply and install cable complete with termination, 2 no


splices, tags, conduit and all necessary supporting
accessories
Page 6/Sub bill 6.9/22 To Collection

Sanitary Fitting

Install the following sanitary fixtures complete with


all necessary fittings and joints to pipework as
specified

A WC and eco washer 2 no


B Custom-made terrazzo basin LF-18 4 no

C Washhand basin mixer 4 no

D Custom-made terrazzo bathtub LF-19 2 no

E Bathtub mixer 2 no

F Rain shower head, hand shower and thermostatic


mixer 2 no

G Floor outlet 6 no

H Pantry sink and tapware 1 no


Sanitary Fitting To Collection

COLLECTION

Page 6/Sub bill 6.9/17 Rp.

Page 6/Sub bill 6.9/18 Rp.

Page 6/Sub bill 6.9/19 Rp.

Page 6/Sub bill 6.9/20 Rp.

Page 6/Sub bill 6.9/21 Rp.

Page 6/Sub bill 6.9/22 Rp.

Sanitary Fitting Rp.


SUB BILL NO. 6.9: PLUMBING INSTALLATIONS Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF


SUB BILL NO. 6.10: EXTERNAL WORKS

Code Description Quantity Unit

GATE AND GARDEN WALL

Local red brick wall with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A To external walls, 150mm thick (Provisional) 53 m2

Paras Kerobokan stone bedded and jointed in mortar


as specified

B To external walls, 150mm thick (Provisional) 53 m2

Bangkirai wood plank size 180x3000x15mm complete


with all fixing accessories

C To external walls finishes at Main Entry 5 m2

Decorative column including blockwork, Andesit stone


tiles 20mm thick surface finishes as specified

D Decorative column size 360 x 250mm and 3250mm 2 no


high at Main Entry
Decorative wall incuding blockworks, carved stone,
andesit stone tiles 20mm thick as specified

E Decorative wall 10 m2

CANOPY AT PATHWAY

F Canopy overall size 3630 x 2925mm comprising of 1 ls


10mm thick tempered clear glass, 40x40mm wood
framescomplete with all necessary fixing accessories

Page 6/Sub bill 6.10/24 To Collection

0.00 POOL DECK

Supply and install Bangkirai solid wood deck size


20x90mm and full length ex. Lante Kayu complete with
required joists, backings and all fixing accessories to
strictly follow manufacture instructions

A Pool Deck 6 m2

0.00 POOL

Mozaic tiles size 75x75mm ex. Wisma Sehati bedded


and jointed in mortar
B To pool wall finishes 34 m2

C To pool floor finishes 23 m2

D To pool treads, 300mm wide 2 m

E To pool risers, 75mm high 1 m

F To pool risers, 225mm high 2 m

G Ditto but 280mm high 1 m

Andesit stone bedded and jointed in mortar as


specified

H To pool skirting size 20x120x300mm, 120mm high 34 m

I To pool gutter 14mm thick complete with shadow lines 23 m2

Lemkra Stone Paint rough plaster applied strictly


according to the manufacturer instructions

J Texture wall paint finish 35 m2

Waterprrofing coating as specified

K Waterproofing coating to pool and gutter area 114 m2

Page 6/Sub bill 6.10/25 To Collection

BALANCING AND PUMP ROOM


15 mm thick plaster comprising 12 mm thick premixed
dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish ex. Mortar
Utama

A
To walls, 25 mm thick 44 m2

Floor hardener ex. Flowcrete as specified

B
To floor finishes 15 m2

Steel door as specified

C Steel door to pump room overall size 980 x 2000mm 1 no


Page 6/Sub bill 6.10/26 To Collection

COLLECTION

Page 6/Sub bill 6.10/24 Rp.

Page 6/Sub bill 6.10/25 Rp.

Page 6/Sub bill 6.10/26 Rp.


SUB BILL NO. 6.10: EXTERNAL WORKS Summary Bill No. 6 Rp.

BILL NO. 6: TWO BEDROOM VILLA - FLAT ROOF

Code Description Quantity Unit

SUMMARY

SUB BILL NO. 6.1: SUB STRUCTURE

SUB BILL NO. 6.2: UPPER STRUCTURE

SUB BILL NO. 6.3: ROOF COVERING

SUB BILL NO. 6.4: EXTERNAL ENVELOPE

SUB BILL NO. 6.5: INTERNAL WALLS AND


PARTITIONS

SUB BILL NO. 6.6: FLOOR FINISHES

SUB BILL NO. 6.7: WALL FINISHES

SUB BILL NO. 6.8: CEILING FINISHES


SUB BILL NO. 6.9: PLUMBING INSTALLATIONS

SUB BILL NO. 6.10: EXTERNAL WORKS

TOTAL 1 UNIT TWO BEDROOM VILLA - FLAT ROOF

TOTAL 4 UNIT TWO BEDROOM VILLA - FLAT ROOF

SUMMARY NO. 6: TWO BEDROOM VILLA - FLAT ROOF To Final Summary


BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF
SUB BILL NO. 7.1: SUB STRUCTURE
ORIGINAL

Code Description Quantity Unit

SUB STRUCTURE

General

A Allow for providing all plant and equipment on site for ls


the installation of the piles including moving the plant
and equipment about the site, the provision of
temporary supports as required during the execution of
the works and for removing the plant and equipment
from site on completion of the works

B Allow for submission of records in triplicate of all bored ls


piles installed, duly signed by the Contractor and
deliver to the Project Manager as the work proceeds

C Allow for the submission of a drawing showing the final ls


plan position of each pile reference by a serial number
and the levels of the bottom and top of each pile as
installed

Bored Tension Piles

Note:
Bored pile, 300mm diameter ( …. no)

D Boring, 300mm diameter from bottom level pile cap to m


proposed bored pile level (6 m)

E Install temporary caison / liner as necessary and no


subsequently remove

F Concrete filling (K-300), to 300mm diameter pile (6 m) m3

G General reinforcing bar 13 mm diameter kg

H General reinforcing bar 8 mm diameter kg

I Remove surplus excavated material/soil disposal from m3


site

Page 6/Sub bill 7.1/1 To Collection Rp.

Pile Testing

A Allow for providing and mobilizing all necessary ls


equipment, materials and labour to carry out axial and
lateral load tests

B Carry out axial compression load test on 300mm no


diameter pile (PDA Test Dinamis)

C Carry out lateral load test on 300mm diameter pile no

D Carry out PIT test on working pile size 300mm no


diameter ramdomly

E Clean up and remove load testing equipment from site ls


on completion of the load testing works
F Allow for recording results and providing reports as ls
specified

Page 6/Sub bill 7.1/2 To Collection Rp.

Excavation

Note: The quantities given are the net volume,


allowance for additional excavation to provide working
space shall be included in the unit rates

A Excavation not exceeding 1.5 m deep commencing 29 m3


from existing level

B Backfilling with selected excavated material 15 m3

C Remove surplus excavated material from site 14 m3

Temporary dewatering

D Allow for providing a temporary dewatering system 1 ls


during the excavation process as required

Anti termite

E Apply anti termite to excavated surface area as 1 ls


specified

Compacted sand bed

F Compacted sand, 100mm thick under pile caps 23 m2

G Ditto, under tie beams 8 m2

H Ditto, under ground slab 46 m2

Lean concrete

I Lean concrete, 50mm thick under pile caps 23 m2

J Ditto, under tie beams 8 m2


K Ditto, under ground slab 46 m2

Page 6/Sub bill 7.1/3 To Collection

Prepare and apply damp proof polythene sheet as


specified

A To undersides of ground slab and tie beams 54 m2

Vibrated reinforced concrete grade K-300

B To pile caps 6 m3

C To tie beams 3 m3

D To ground slab 2 m3

E To ground slab edge 240mm high 1 m3

F To stump column 1 m3

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables

G General reinforcing bars in pile caps, 16mm diameter 518 kg

H ditto, 13mm diameter 750 kg

I ditto, 8mm diameter 22 kg

J General reinforcing bars in tie beams, 13mm diameter 305 kg

K ditto, 10mm diameter 196 kg

L General reinforcing bars in ground slab edge , 13mm 150 kg


diameter (Provisional)

M ditto, 10mm diameter (Provisional) kg

N General reinforcing bars in stump column (Provisional) 150 kg

Page 6/Sub bill 7.1/4 To Collection


Wiremesh M5 (1 layer) including joint anchor, as
specified

A to ground slab 44 m2

Supply and install formwork as specified

B To sides of pile caps 22 m2

C To edges of tie beams 28 m2

D To edges of slab 50mm high 47 m

E To ground slab edge 240mm high 14 m

F To stump column 11 m2

Page 6/Sub bill 7.1/5 To Collection

COLLECTION

Page 6/Sub bill 7.1/1 Rp.

Page 6/Sub bill 7.1/2 Rp.

Page 6/Sub bill 7.1/3 Rp.

Page 6/Sub bill 7.1/4 Rp.

Page 6/Sub bill 7.1/5


SUB BILL NO. 7.1: SUB STRUCTURE Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 7.2: UPPER STRUCTURE

Code Description Quantity Unit

UPPER STRUCTURE

Vibrated reinforced concrete grade K-300

A Columns 8 m3

B Beams (Provisional) 12 m3

C Ring beams (Provisional) 4 m3

D Slab above pump room 16 m3

Supply and install bar reinforcement; deform steel


BJTP 24 ≤ Ø12mm ,BJTD 40 > Ø12mm including
bending, cutting to length and supplying and installing
all tying wire, accessories and consumables

E General reinforcing bars in columns (Provisional) 2,400 kg

F Stirrups in columns kg
G General reinforcing bars in beam, 19mm diameter 436 kg
(Provisional)

H ditto, 16mm diameter (Provisional) 1,433 kg

I Stirrups in beam, 10mm diameter (Provisional) 798 kg

J General reinforcing bars in ring beam (Provisional) kg

K General reinforcing bars in slab above pump room, 2,011 kg


10mm diameter

Supply and install formwork as specified

L To sides of columns 85 m2

M To sides and soffit of beam (Provisional) 121 m2

N To sides and soffit of ring beam (Provisional) 69 m2

O To soffit of Slab above pump room (Provisional) 105 m2

Page 6/Sub bill 7.2/5 To Collection

PLUNGE POOL AND PUMP ROOM

Vibrated reinforced concrete grade K-250

A 7 m3
Pool slab

B 7 m3
Pool wall

C 8 m3
Pool gutter

D
Pump room & balancing tank slab (Provisional) 2 m3

E
Pump room & balancing tank wall (Provisional) m3

Supply and install bar reinforcement; deform steel


BJTP 24 ,BJTD 40 including bending, cutting to
length and supplying and installing all tying wire,
accessories and consumables

F
General reinforcing bars in pool slab, 13mm diameter 782 kg

G General reinforcing bars in pool wall, 13mm diameter 1,060 kg

H General reinforcing bars in pool gutter, 13mm 717 kg


diameter
I General reinforcing bars in Pump room & balancing 244 kg
tank slab, 10mm diameter

J General reinforcing bars in Pump room & balancing kg


tank wall, 10mm diameter (Provisional)

Supply and install formwork as specified

K 26 m2
To soffit of slab

L
To edges of slab 250mm high 32 m
M
To sides of pool wall and gutter 148 m2

N
To sides of pump room and balancing tank slab 18 m2

O To sides of pump room and balancing tank wall m2


(Provisional)

Page 6/Sub bill 7.2/6 To Collection

COLLECTION

Page 6/Sub bill 7.2/5 Rp.

Page 6/Sub bill 7.2/6 Rp.


SUB BILL NO. 7.2: UPPER STRUCTURE Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 7.3: ROOF COVERING

Code Description Quantity Unit

ROOF STEEL STRUCTURE

Fabricate and install roof steel structure including


cutting, fabricating, assembling, welding, connections,
surface treatment prior to erection, fixing in place and
all necessary fixings and accessories

A WF 200x100x5.5x8 1,038 kg

B WF 150x75x5x7 146 kg

C 2-L 50x50x5 65 kg

D CNP 125x50x20x3.2 843 kg

E Trekstang - Ø12 mm 37 kg

F Wind bracing - D16mm 131 kg

G 10mm thick Plate, bolt, embeded and stiffeners 1 ls

I Anchor Bolt M16 x 300mm length 16 no

Paint Finishes

J Epoxy/ Marine Paint 2,260 kg

Page 6/Sub bill 7.3/8

To Collection

ROOFING
Concrete wood panel size 20x3000mm and 14mm
thick on and including hollow steel 40x40mm framings,
angle bar complete with all fixings and installed in
accordance with the manufactures instructions

A
Timber plank roofing 170 m2

B
Ridge 15 m

Roof insulation comprising of metal deck,


waterproofing membrane, 12mm thick multiplex
complete with all necessary fixing accessories as
specified
C
Insulation to pitched roof 170 m2

Flashing zinc 3 mm thick complete with all fixings

D
Flashing 15 m

Roof gutter to pitch roof comprising of timber frames,


mortar screed, 4mm thick flashing zinc and
waterproofing

E
Roof gutter size 200 x 210mm 29 m

Supply and install approved waterproofing system in


accordance with the manufactures instructions as
specified

F To concrete roof slab 10 m2

30 mm thick protective cement and sand (1:5) screed


laid to falls over waterproof membrane to roof as
specified

G To concrete roof slab 10 m2

Andesite stone plank size 300 x 280mm and 20mm


thick bedded and jointed in mortar as specified

H To roof slab 10 m2

Supply and install cast iron roof outlet complete with all
necessary fixing accessoris

H
Roof drain 2 no

Page 6/Sub bill 7.3/9 To Collection

0.00 ROOFING (Cont'd)

Supply and install 25 mm thick solid wood fascia


complete with 4 mm thick steel plate cover and all
necessary fixing accessoris

A
Solid wood fascia 300 mm wide 51 m
Page 6/Sub bill 7.3/10 To Collection

COLLECTION

Page 6/Sub bill 7.3/8 Rp.

Page 6/Sub bill 7.3/9 Rp.

Page 6/Sub bill 7.3/10 Rp.


SUB BILL NO. 7.3: ROOF COVERING Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 7.4: EXTERNAL ENVELOPE

Code Description Quantity Unit

Hebel block walls with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A To walls, 150mm thick 221 m2

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish ex. Mortar
Utama

B
To walls, 25 mm thick 264 m2

Texture paint ex. Lemkra Stone Paint applied strictly


according to the manufacturer instructions

C Texture wall paint finish 264 m2

Jati Doreng Timber Screens complete with frames and


all fixing accessories

D
Timber screen overall size 1100 x 3200mm high 2 no
Page 6/Sub bill 7.4/12 To Collection

DOORS AND WINDOWS

Doors

Supply and install aluminum doors, complete with


aluminum frames and jambs, 8mm thick clear glass
leaf door, main track system for sliding door,
hardwares as specified and all fixing accessories

A Double sliding door and double fixed panel, overall 2 no


size 4650 x 2550mm at Bedroom (D02)

B Double sliding door and double fixed panel, overall 1 no


size 4400 x 2550mm at Bedroom (D03)

Supply and install engineered wood doors, complete


with solid timber frames, solid timber jambs, hardwares
as specified and all fixing accessories

C Double swing door, overall size 1100 x 2550mm at 1 no


Main Entrance (D04)

Steel door with steel plate frame and 9 mm thick


calcium silicate board and textured paint finish
complete with hardwares and all necessary
accessories as specified

D Single pivot door, overall size 550 x 1500mm at Dry 2 no


Garden (D05)

Windows

E 2 no
Fixed glass window, 10mm thick tempered clear glass,
overall size 2650 x 2400mm high complete with all
fixing accessories (W01)

F 2 no
Fixed glass window, 10mm thick tempered clear glass,
overall size 460 x 1220mm high complete with all fixing
accessories (W02)

G 2 no
Pivot glass window, 10mm thick tempered clear glass,
overall size 1100 x 1620mm high complete with
hardwares and all fixing accessories (W03)

Page 6/Sub bill 7.4/13 To Collection


COLLECTION

Page 6/Sub bill 7.4/12 Rp.

Page 6/Sub bill 7.4/13 Rp.

SUB BILL NO. 7.4: EXTERNAL ENVELOPE Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 7.5: INTERNAL WALLS AND PARTITIONS

Quantity Unit
Code Description

Hebel block walls with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A 81 m2
To walls, 100mm thick

B To walls, double cavity walls 300 mm wide surround 31 m2


pocket sliding door
SUB BILL NO. 7.5: INTERNAL WALLS AND PARTITIONS Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 7.6: FLOOR FINISHES

Code Description Quantity Unit

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

A To bathroom floor 24 m2
SUB BILL NO. 7.6: FLOOR FINISHES Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 7.7: WALL FINISHES

Code Description Quantity Unit

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish

A
To walls, 25 mm thick 139 m2

Supply and install approved CL waterproofing system


in accordance with the manufactures instructions as
specified

B To bathroom wall 39 m2
SUB BILL NO. 7.7: WALL FINISHES Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 7.8: CEILING FINISHES

Code Description Quantity Unit

Lambrisering ceiling on and including 40 x 40 mm


hollow steel suspension system including joints,
shadow line and all fixing accessories as specified

A
Suspended ceiling external 47 m2

B
Suspended ceiling internal m2

9,5 mm thick water resistant gypsum board ceiling ex.


USG Boral with concealed suspension system
including 25 mm shadow line and all fixing accessories
as specified

B Suspended ceiling at bathroom m2

C Suspended ceiling at basement 125 m2

Prepare and apply one coat alkali resiting primer, one


coat water based emulsion sealer and two finishing
coats of emulsion paint as specified

D Paint calcium silicate board ceiling 125 m2


SUB BILL NO. 7.8: CEILING FINISHES Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 7.9: PLUMBING INSTALLATIONS

Code Description Quantity Unit

COLD WATER SYSTEM

PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 32 mm diameter pipework 4 m

B 25 mm diameter ditto 14 m

C 20 mm diameter ditto 18 m

D 15 mm diameter ditto 60 m

Valve and ancillaries including joints to pipeworks

E 20 mm diameter gate valve 1 no

F 20 mm diameter floating valve 1 no


Page 6/Sub bill 7.9/19 To Collection

HOT WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Head pump, Heating capacity 2.7 Kw , rated input 1 unit


power 0.6 Kw /220/1/50Hz, Rated hot water output 90
L/h, Max. water temperatur 55° C, model : HPU 2.7-
060 P, complete with control panel, valve and all
accessories.

B Presure hot water tank, capacity 300 L, presurized 1 unit


vertical tank type, inner tank - enamel t, working
presure maximal 5 bar,insulation high density
polyurethane Non CFC, cover almunium 1 mm finish
weet coat, model PT - 300 L . complete with sensor,
valve, safety valve, and all accessories.

PIPEWORK

Supply and install polypropylene PN 20, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

C 20mm diameter pipework 28 m

D 15 mm diameter ditto 36 m

Page 6/Sub bill 7.9/20 To Collection


WASTE & DRAIN WATER SYSTEM

EQUIPMENT

Supply and install septictank package (Biotek) and


including all necessary supporting accessories as
required in accordance with the specifications,
drawings and manufacturer's instructions as described

A Septitank package ( Biotek) with capacity 1.5 m3 1 set


complete with all accessories

B Portable Grease trap 1 set

PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

C 100 mm diameter, pipework 40 m

D 80 mm diameter, ditto 5 m

E 65 mm diameter, ditto 12 m

F 40 mm diameter, ditto 4 m

G 32 mm diameter, ditto 12 m

Page 6/Sub bill 7.9/21 To Collection

WASTE & DRAIN WATER SYSTEM (Cont'd)

Extra over pipework

A Bend 90 degree, 100 mm diameter 3 no

B Bend 90 degree, 65 mm diameter 8 no

C Bend 45 degree, 100 mm diameter 4 no

D Bend 45 degree, 65 mm diameter 10 no

E Tee diameter 100 x 100 x 100 mm 4 no


F Tee diameter 100 x 100 x 65 mm 4 no

G Tee diameter 100 x 100 x 32 mm 4 no

H Tee diameter 80 x 80 x 65 mm 2 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

I 50 mm diameter, pipework 6 m

32 mm diameter, ditto 12 m

Valve and ancillaries including joints to pipeworks

J Vent cup 2 no

Page 6/Sub bill 7.9/22 To Collection

RAIN WATER SYSTEM

PIPEWORK

Supply and install Polyvinyl chloride ( PVC ) pipe, AW


type Class 10 kg/cm2, fixed in position complete with
support, hangers and other necessary fixing and
jointing materials in accordance with the specification

A 100 mm diameter, pipework 59 m

Extra over pipework

B Bend 90 degree, 100 mm diameter 6 no

C Bend 45 degree, 100 mm diameter 10 no

D Tee diameter 100 x 100 x 100 mm 2 no

Valve and ancillaries including joints to pipeworks

E 100 mm diameter roof drain 4 no


Page 6/Sub bill 7.9/23 To Collection

ASSOCIATED ELECTRICAL WORK

A Supply and install cable complete with termination, 2 no


splices, tags, conduit and all necessary supporting
accessories
Page 6/Sub bill 7.9/24 To Collection

COLLECTION

Page 6/Sub bill 7.9/19 Rp.

Page 6/Sub bill 7.9/20 Rp.

Page 6/Sub bill 7.9/21 Rp.

Page 6/Sub bill 7.9/22 Rp.

Page 6/Sub bill 7.9/23 Rp.

Page 6/Sub bill 7.9/24 Rp.

SUB BILL NO. 7.9: PLUMBING INSTALLATIONS Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF


SUB BILL NO. 7.10: EXTERNAL WORKS

Code Description Quantity Unit

GATE AND GARDEN WALL


Local red brick wall with cement and sand (1:2),
including reinforced concrete practical columns and tie
beams

A To external walls, 150mm thick (Provisional) 86 m2

Paras Kerobokan stone bedded and jointed in mortar


as specified

B To external walls, 150mm thick (Provisional) 53 m2

Bangkirai wood plank size 180x3000x15mm complete


with all fixing accessories

C To external walls finishes at Main Entry 53 m2

Decorative column including blockwork, Andesit stone


tiles 20mm thick surface finishes as specified

D Decorative column size 360 x 250mm and 3250mm 2 no


high at Main Entry

Decorative wall incuding blockworks, carved stone,


andesit stone tiles 20mm thick as specified

E Decorative wall 10 m2

CANOPY AT PATHWAY

F Canopy overall size 3630 x 2925mm comprising of 1 ls


10mm thick tempered clear glass, 40x40mm wood
framescomplete with all necessary fixing accessories

Page 6/Sub bill 7.10/26 To Collection

0.00 POOL DECK

Supply and install Bangkirai solid wood deck size


20x90mm and full length ex. Lante Kayu complete with
required joists, backings and all fixing accessories to
strictly follow manufacture instructions

A Pool Deck 6 m2

0.00 POOL

Mozaic tiles size 75x75mm ex. Wisma Sehati bedded


and jointed in mortar

B To pool wall finishes 34 m2

C To pool floor finishes 23 m2


D To pool treads, 300mm wide 2 m

E To pool risers, 75mm high 1 m

F To pool risers, 225mm high 2 m

G Ditto but 280mm high 1 m

Andesit stone bedded and jointed in mortar as


specified

H To pool skirting size 20x120x300mm, 120mm high 34 m

I To pool gutter 14mm thick complete with shadow lines 23 m2

Lemkra Stone Paint rough plaster applied strictly


according to the manufacturer instructions

J Texture wall paint finish 35 m2

Waterprrofing coating as specified

K Waterproofing coating to pool and gutter area 114 m2

Page 6/Sub bill 7.10/27 To Collection

BALANCING AND PUMP ROOM

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish ex. Mortar
Utama

A
To walls, 25 mm thick 44 m2

Floor hardener ex. Flowcrete as specified

B
To floor finishes 15 m2

Steel door as specified

C Steel door to pump room overall size 980 x 2000mm 1 no


Page 6/Sub bill 7.10/28 To Collection

COLLECTION

Page 6/Sub bill 7.10/26 Rp.

Page 6/Sub bill 7.10/27 Rp.

Page 6/Sub bill 7.10/28 Rp.


SUB BILL NO. 7.10: EXTERNAL WORKS Summary Bill No. 7 Rp.

BILL NO. 7: TWO BEDROOM VILLA - PITCH ROOF

Code Description Quantity Unit

SUMMARY

SUB BILL NO. 7.1: SUB STRUCTURE

SUB BILL NO. 7.2: UPPER STRUCTURE

SUB BILL NO. 7.3: ROOF COVERING

SUB BILL NO. 7.4: EXTERNAL ENVELOPE

SUB BILL NO. 7.5: INTERNAL WALLS AND


PARTITIONS

SUB BILL NO. 7.6: FLOOR FINISHES

SUB BILL NO. 7.7: WALL FINISHES

SUB BILL NO. 7.8: CEILING FINISHES

SUB BILL NO. 7.9: PLUMBING INSTALLATIONS

SUB BILL NO. 7.10: EXTERNAL WORKS

TOTAL 1 UNIT TWO BEDROOM VILLA - PITCH


ROOF

TOTAL 18 UNIT TWO BEDROOM VILLA - PITCH


ROOF

SUMMARY NO. 7: TWO BEDROOM VILLA - PITCH ROOF To Final Summary


BILL NO. 8: SITEWORKS
SUB BILL NO. 8.1: STRUCTURE
ORIGINAL

Code Description Quantity Unit

BORED PILES

General

A Allow for providing all plant and equipment on site for 1 ls


the installation of the piles including moving the plant
and equipment about the site, the provision of
temporary supports as required during the execution of
the works and for removing the plant and equipment
from site on completion of the works

B Allow for submission of records in triplicate of all bored 1 ls


piles installed, duly signed by the Contractor and
deliver to the Project Manager as the work proceeds

C Allow for the submission of a drawing showing the final 1 ls


plan position of each pile reference by a serial number
and the levels of the bottom and top of each pile as
installed

Bored Tension Piles

Note:
Bored pile, 400mm diameter

D Boring, 400mm diameter from bottom level to proposed 984 m


bored pile level

E Install temporary caison / liner as necessary and no


subsequently remove

F Concrete filling fc' 30 Mpa, to 400mm diameter pile 124 m3

G General reinforcing bar; deformed high tensile steel 6,944 kg


BJTS 40, 16mm diameter

H General reinforcing bar; deformed high tensile steel 2,604 kg


BJTS 40, 8mm diameter

I Spiral stirrups; deformed high tensile steel BJTD 24, 4,092 kg


10mm diameter
J Remove surplus excavated material/soil disposal from 124 m3
site

Page 6/Sub bill 8.1/1 To Collection

Pile Testing

A Allow for providing and mobilizing all necessary 1 ls


equipment, materials and labour to carry out axial and
lateral load tests

B Carry out axial compression load test on 400mm 3 no


diameter pile - PDA Test Dinamis

C Carry out lateral load test on 400mm diameter pile 3 no

D Carry out PIT test on working pile size 400mm 3 no


diameter ramdomly

E Clean up and remove load testing equipment from site 1 ls


on completion of the load testing works

F Allow for recording results and providing reports as 1 ls


specified
Page 6/Sub bill 8.1/2 To Collection

EXTERNAL STAIRS

INCLINATOR

PATHWAYS
Page 6/Sub bill 8.1/3 To Collection

COLLECTION

Page 6/Sub bill 8.1/1 Rp.

Page 6/Sub bill 8.1/2 Rp.

Page 6/Sub bill 8.1/3 (Prov Sum)


SUB BILL NO. 8.1: STRUCTURE Summary Bill No. 8 Rp.

BILL NO. 8: SITEWORKS


SUB BILL NO. 8.2: PLUMBING INSTALLATIONS

Code Description Quantity Unit


SITEWORKS

COLD WATER SYSTEM

TRANSFER & DISTRIBUTION PIPEWORK

Supply and install HDPE PN-16 pipe, fixed in position


complete with trench excavation, bendding, surround,
haunching and backfilling and concrete / thiclening and
other necessary fixing and jointing materials as
specified

A 100 mm diameter pipework 230 m

B 80 mm diameter, ditto 155 m

C 65 mm diameter, ditto 176 m

D 50 mm diameter, ditto 493 m

E 32 mm diameter, ditto 0 m

F 25 mm diameter, ditto 180 m

Extra over pipework

G Tee diameter 100 x 100 x 100 2 no

H Tee diameter 100 x 100 x 80 1 no

I Tee diameter 100 x 100 x 65 8 no

J Tee diameter 100 x 100 x 50 8 no

K Tee diameter 80 x 80 x 80 2 no

L Tee diameter 80 x 80 x 65 2 no

M Tee diameter 80 x 80 x 50 6 no

N Tee diameter 65 x 65 x 13 13 no

O Bend 45 degree , 100 mm diameter 4 no

P Bend 90 degree , 100 mm diameter 3 no

Valve and ancillaries including joints to pipeworks


L 100 mm diameter gate valve 4 no

Q 50 mm diameter ditto 13 no

N 32 mm diameter ditto 5 no

R 25 mm diameter ditto 100 no

S 25 mm diameter Water meter 20 no

T 65 mm diameter gate valve 2.00 no

Page 6/Sub bill 8.2/5 To Collection

SITEWORKS (Cont'd)

COLD WATER SYSTEM

DEEP WELL

Supply and install the following deep wells complete


with supporting and accessories

A - Making of deepwell with capacity 200 liter/minutes,


1 ls
with covering works :
- Managing permit to body observation of ground water
- Geoelectric test
- Drilling of deepwell
- Supply and install of pump for the deep of well
complete with valve and accessories
- Supply and install of pipe to water tub under
- Filling bore hole around stainless steel screen with
washed gravel
- Removing surplus excavated material from site
- Filling bore hole around casing with sand
- Deep well control box, including excavation, back fill,
remove surplus materials, steel checker plate cover
and hardware
- Associated Electrical Work
- Allow for laboratory testing of water
- Allow for providing guarantee for capacity and
quality of pumping water
Page 6/Sub bill 8.2/6 To Collection

PUMP ROOM

COLD WATER SYSTEM

EQUIPMENT

Supply and install pump units on and including spring


vibration isolators and all necessary supporting
accessories as required in accordance with the
specifications, drawings and manufacturer's
instructions as described :

A Booster pump (BP-101.1A/B/C) , VSD booster pump 1 set


package, Centrifugal End Suction type, with capacity
200 LPM, head 30 m and electric power 1 kW, parallel
alternate, complete with pressure transducer, pressure
tank, control panel, valve and accessories. (1 set = 3
pump)
B Booster pump (BP-102.1A/B/C) , VSD booster pump 1 set
package, Centrifugal End Suction type, with capacity
200 LPM, head 30 m and electric power 1 kW, parallel
alternate, complete with pressure transducer, pressure
tank, control panel, valve and accessories. (1 set = 3
pump)

C Transfer pump (TP-102.1A/B/C) , Centrifugal End 1 set


Suction type, with capacity 600 LPM, head 35 m and
electric power 5.5 kW, 1 duty - 1 standby, complete with
control panel, valve and accessories. (2 units/set)

D Sand filter (SF-1), FRP material with capacity 600 L/m, 1 unit
filtration velocity 40 m/hr.

E Carbon filter (CF-1), FRP material with capacity 600 1 unit


L/m, filtration velocity 40 m/hr.

F Sump pump (PSP.1A & B) submersible open impeller 1 set


pump type, with capacity 100 lpm, head 20 m, electrical
power 1,5 kW, parallel alternate, non-clog, complete with
control panel valve,floating switches and accesories (2
units/set)

Page 6/Sub bill 8.2/7 To Collection

PUMP ROOM

COLD WATER SYSTEM (Cont'd)

PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

A 250 mm diameter Header, with ± 7 m length 1 no


B 150 mm diameter Header, with ± 4 m length 1 no

C 150 mm diameter Header, with ± 2 m length 3 no

A 150 mm diameter Header, with ± 4 m length 1 no

B 150 mm diameter Header, with ± 2 m length 3 no

C 150 mm diameter pipework 8 m

D 100 mm diameter ditto 65 m

E 80 mm diameter ditto 10 m

F 50 mm diameter ditto 10 m

Extra over pipework

G 100 mm diameter, Tee 10 no

H Bend 90 degree, 100 mm diameter 12 no

Page 6/Sub bill 8.2/8 To Collection

PUMP ROOM
COLD WATER SYSTEM (Cont'd)

Valve and ancillaries including joints to pipeworks

A 150 mm diameter gate valve 2 no

B 100 mm diameter, ditto 11 no

C 80 mm diameter, ditto 2 no

D 50 mm diameter, ditto 12 no

E 100 mm diameter Strainer 2 no

F 50 mm diameter, ditto 12 no

G 100 mm diameter Flexible Joint 2 no

H 80 mm diameter, ditto 2 no

I 50 mm diameter, ditto 12 no

J 80 mm diameter Check Valve 2 no

K 50 mm diameter, ditto 12 no

L 100 mm diameter Floating valve 2 no

M 65 mm diameter, ditto 12 no

Supply and install GIP pipe, fixed in position complete


with all supports, hangers and other necessary fixing
and jointing material in accordance with the
specification

N 50 mm diameter pipework 12 m
Page 6/Sub bill 8.2/9 To Collection

COLLECTION

Page 6/Sub bill 8.2/5 Rp.

Page 6/Sub bill 8.2/6 Rp.

Page 6/Sub bill 8.2/7 Rp.

Page 6/Sub bill 8.2/8 Rp.

Page 6/Sub bill 8.2/9 Rp.


SUB BILL NO. 8.2: PLUMBING INSTALLATIONS Summary Bill No. 8 Rp.

BILL NO. 8: SITEWORKS


SUB BILL NO. 8.3: MINOR BUILDING

Code Description Quantity Unit

INCLINATORS

Inclinator car lift overall size 1820 x 2130 mm and


1200 mm high comprising of 4mm thick aluminum
composite panel ex. Seven, andesite stone floor finish,
automatic sliding door inaluminum composite panel
complete with hardwares and all fixing accessories

A Inclinator car lift 2 no

Inclinator Terminal including structural works and


finishings as specified
B Inclinator terminal 12 no
INCLINATORS To Collection

MAID ROOM

Wall partitions and finishes

Hebel block walls with cement and sand (1:2),


including reinforced concrete practical columns and tie
beams

A To walls, 150mm thick 56 m2

15 mm thick plaster comprising 12 mm thick premixed


dry mortar render base coat and 3 mm thick premixed
dry mortar skim coat with smooth finish ex. Mortar
Utama

B
To walls, 25 mm thick 98 m2
Interior paint ex. Propan applied strictly according to
the manufacturer instructions

C Internal wall 52 m2

Texture paint ex. Lemkra Stone Paint applied strictly


according to the manufacturer instructions

D Texture wall paint finish 46 m2

Cement and sand (1:5) screed as specified

E
35 mm thick screed to receive ceramic tile wall 9 m2

Ceramic tile ex. Dpanama Perca size 200x200mm


bedded and jointed in mortar

F
Wall finishes 9 m2

Doors

G Supply and install wood louver door overall size 1000 x 1 no


2400 mm complete with bangkiray solid wood frames
in duco paint finish, hardwares as specified and all
fixing accessories (D02)

Page 6/Sub bill 8.3/12 To Collection

MAID ROOM (Cont'd)

Doors (Cont'd)

A Supply and install hollow timber door overall size 1000 1 no


x 2400 mm complete with bangkiray solid wood frames
in duco paint finish, hardwares as specified and all
fixing accessories (D03)
B Supply and install engineered wood door overall size 1 no
800 x 2400 mm complete with bangkiray solid wood
frames in duco paint finish, PVC louvers, hardwares as
specified and all fixing accessories (D04)

C Supply and install double swing steel door overall size 1 no


1200 x 1100 mm complete with steel frames, 9mm
thick calcium silicate board door leaf, hardwares as
specified and all fixing accessories (D01)

Floof finishes

Cement and sand (1:5) screed as specified

D 30 mm thick screed to floor to receive ceramic floor 16 m2

Ceramic tile ex. Roman size 400x400mm bedded and


jointed in mortar

E
Floor finishes 14 m2

Ceramic tile ex. Roman size 200x200mm bedded and


jointed in mortar

F
Floor finishes 2 m2

Page 6/Sub bill 8.3/13 To Collection

MAID ROOM (Cont'd)

Ceiling finishes
13 mm thick waterproof gypsum board suspended
ceiling with seamless joint including framing, joints, trim
and all fixing accessories as specified

A Ceiling finishes 16 m2

Interior paint ex. Propan applied strictly according to


the manufacturer instructions

B Ceiling finishes 16 m2

Millworks

C Pantry counter as specified overall size 650 x 2000 1 no


mm and 1400 mm high

Plumbing Installations

COLD WATER SYSTEM

PIPEWORK

Supply and install polypropylene PN 16, fixed in


position complete with all supports, hangers and other
necessary fixing and jointing material in accordance
with the specification

D 25 mm diameter pipework 15 m

E 20 mm diameter ditto 4 m

F 15 mm diameter ditto 16 m

Page 6/Sub bill 8.3/14 To Collection


MAID ROOM (Cont'd)

WASTE & DRAIN WATER SYSTEM

PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, AW type Class 10 kg/cm2, fixed in
position complete with support, hangers and other
necessary fixing and jointing materials in accordance
with the specification

A 100 mm diameter, pipework (Provisional) 12 m

B 50 mm diameter, ditto 6 m

C 40 mm diameter, ditto 8 m

Extra over pipework

D Bend 90 degree, 100 mm diameter 1 no

E Tee diameter 100 x 100 x 50 mm 2 no

VENT PIPEWORK

Supply and install Unplasticised Polyvinyl chloride


( uPVC ) pipe, Class D 5 kg/cm2, fixed in position
complete with support, hangers and other necessary
fixing and jointing materials in accordance with the
specification

F 50 mm diameter, pipework (provisional quantity) 15 m

Extra over pipework

E Vent Cup 1 no
Page 6/Sub bill 8.3/15 To Collection

COLLECTION

Page 6/Sub bill 8.3/12

Page 6/Sub bill 8.3/13

Page 6/Sub bill 8.3/14

Page 6/Sub bill 8.3/15

TOTAL 1 UNIT MAID ROOM


TOTAL 7 UNIT MAID ROOM

To Collection

COLLECTION

INCLINATOR Rp.

MAID ROOM Rp.


SUB BILL NO. 8.3: MINOR BUILDING Summary Bill No. 8 Rp.

BILL NO. 8: SITEWORKS


SUB BILL NO. 8.4: HARD LANDSCAPING

Code Description Quantity Unit

EXTERNAL STAIRS

Railing comprising of Paras Kerobokan surface


finishes, 5mm thick stainless steel hairline and
diameter 10mm stainless pipe hand railing, shadow
line U channel size 30x30mm complete with all
nexessacry support, screedings and necessary fixing
accessories (concrete works include to Provisional
Sum)

A Railing size 200 x 1100mm high 1,111 m

B Ditto size 500 x 1100mm high 887 m

Bangkiray wood railing (refer to dwg AR.VA.07.003)


complete with poles and all fixing accessories
C Railing size 100 x 1100mm high m

Pebblewash finish as specified

D To treads 300mm wide 1,147 m

Plasterworks and aluminum U channel size 20x20mm


as specified

E To risers 150mm high 1,216 m

To Collection

0.00 PATHWAYS AND EXTERNAL WALLS

Drystone for exposed surface finishes of Retaining


Walls complete with all fixing accessories

A Retaining walls surface finishes 2,622 m2


Pebblewash finish as specified

B To pathways and landings 2,616 m2


To Collection

Drive Way and Pedestrian


Supply and install 50mm thk cobblestone, natural
finish, black colour, size 100mm x 100mm, on and
including cement and sand mortar bed and jointing
and pointing all as specified

A To drive and service way 2,615 m2

Supply and install andesit stone, complete with mortar


bed and grout

B To pedestrian finish, size 200 x 200 x 20 mm thick, black 326 m2


colour, finish flamed

Supply and install cansteen finish size 200 x 150 x 20


mm thick, black colour, flamed finish

C To drive and pedestrian way 664 m

Entrance Gate Area

Supply and install andesit stone, complete with mortar


bed and grout

D To security check area, size 200 x 200 x 50 mm thick 70 m2


and 200 x 50 x 50 mm thick, black colour, finish 80 %
Honed and 20 % Hummerbush

Entrance Bridge Area


Supply and install andesit stone, complete with mortar
bed and grout
E To floor of bridge size 200 x 200 x 20 mm thick, black
colour, finish 80 % Honed and 20 % Hummerbush 49 m2

Supply and Install paras silakarang stone finish natural


cover with Moss
F Cover pillar of bridge finish 10 nos
To Collection

Drop Off & Entrance Garden Area

Supply and install andesit stone, complete with mortar


bed and grout
A To wall, andesite susun sirih, dark colour, finish 80%
flamed finish and 20% honed finish
344 m2

B To capping of pond 1, wide 300 mm, black colour,


flamed finish
58 m

C To capping of pond 1,wide 150 mm, black colour,


flamed finish 58 m

D To wall of pond 1 , high 300 mm, black colour, flamed


finish
58 m

E To drop off area, size 200 x 200 x 50 mm thick and 200 m2


x 50 x 50 mm thick, black colour, finish 80 % Honed and
20 % Hummerbush

F To wall, andesite susun sirih, dark colour, finish 80%


flamed finish and 20% honed finish
338 m2
G To capping of upper pond 2, wide 150 mm, black
colour, flamed finish
94 m
H To capping of lower pond 2, wide 300 mm, black
colour, flamed finish
47 m
I To wall of lower pond 2 , high 375 mm, black colour,
flamed finish 47 m

Supply and sandstone, size 160 x 380x 50 mm thick,


grey colour, natural finished
J To Retaining Wall 232 m2

Lobby Roof Garden


Supply and install andesit stone, complete with mortar
bed and grout
K To roof garden area, stepping stone, natural pattern, 12 m2
size minimun diameter 400mm thick, black colour and
natural finish

To Collection

WEST HOTEL GARDEN AREA

Soil Mix

250 - 270 mm depth of soil mix as specified

A To receive west hotel roof garden area 287 m2


500 mm depth of soil mix as specified

B To mound up 24 m2

900 mm depth of soil mix as specified

C To tree pit 7 m2

Versicell 30 mm thick with geotextile layer as


specified

D To west hotel roof garden area 311 m2

50 mm thick compacted sand as specified

E To west hotel roof garden area 311 m2

Drainage pipe as specified (refer to MEP detail)

F To hotel roof garden area 5 nos

Floor finishes

Cement and sand (1:5) screed as specified

G 30 mm thick screed to floor to receive stone 65 m2

400 mm diameter size of andesite stone 'natural


pattern' bedded and jointed in mortar as specified

H 30 mm thick to stepping stone area 65 m2

To Collection

LOBBY ROOF GARDEN

Soil Mix

200 - 250 mm depth of soil mix as specified

A To receive lobby roof garden area 620 m2

300 mm depth of soil mix as specified


B To mound up area (GL +0.35) 10 m2

500 mm depth of soil mix as specified

C To mound up area (GL +0.55) 44 m2

600 mm depth of soil mix as specified

D To mound up area (GL +0.65) 30 m2

200 mm depth of soil mix as specified

E To receive planter 11 m2

Versicell 30 mm thick with geotextile layer as


specified

F To lobby hotel roof garden area 637 m2

G To planter area 24 m2

50 mm thick compacted sand as specified

H To west hotel roof garden area 610 m2

I To planter area 11 m2

Waterproofing membrane as specified

J To floor planter 11 m2

K To side planter 13 m2

Drainage pipe as specified (refer to MEP detail)

L To lawn and planting area 40 nos

M To planter 5 nos

To Collection

LOBBY ROOF GARDEN (cont'd)

Floor finishes

Cement and sand (1:5) screed as specified

A 30 mm thick screed to floor to receive stone 10 m2

400 mm diameter size of andesite stone 'natural


pattern' bedded and jointed in mortar as specified
B 30 mm thick to stepping stone area 10 m2

B1 ROOF GARDEN

Soil Mix

250 - 270 mm depth of soil mix

C To receive lawn and shrubs 277 m2

500 - 600 mm depth of soil mix

D To mound up 16 m2

Versicell 30 mm thick with geotextile layer as


specified

E To west hotel roof garden area 305 m2

50 mm thick compacted sand as specified

F To B1 roof garden 293 m2

Drainage pipe as specified (refer to MEP detail)

G To lawn and shrubs 8 nos

Floor finishes

Cement and sand (1:5) screed as specified

H 30 mm thick screed to receive stone 22 m2

400 mm diameter size of andesite stone 'natural


pattern' bedded and jointed in mortar as specified

I 30 mm thick to stepping stone area 22 m2

To Collection

CLIFF GARDEN

Wall partitions and finishes

950 mm + 100 mm width of brickwork / riverstone


with cement and sand (1:5) as specified

A To wall B1 48 m

650 mm + 100 mm width of brickwork / riverstone


with cement and sand (1:5) as specified

B To wall B2 31 m
Cement and sand (1:5) screed as specified

C
20 mm thick screed to receive Paras Kelating stone 381 m2

D 20 mm thick screed to receive Andesite stone 19 m2

Paras kelating stone random size bedded and


jointed in mortar

E To wall B1, 20 mm thick 256 m2

F To wall B2, 20 mm thick 125 m2

Andesite stone flamed finish bedded and jointed in


mortar

G To top of wall B1, 20 mm thick 19 m2

Lean concrete 1:3:5

H 50mm thick blinding layer below brickwork B1 46 m2

To Collection

INDOOR GARDEN AREA

Versicell 30 mm thick with geotextile layer as


specified

A To B3A (prov sums) 1 ls

B Type 1 at B3 200 m2

C Type 2 at B3 74 m2

D Type 1 at B2 53 m2

E Type 2 at B2 10 m2
F Type 1 at B1 117 m2

G Type 2 at B1 29 m2

Waterpoofing membrane as specified

H To B3A (prov sums) 1 ls

I To B3 275 m2

J To B2 62 m2

K To B1 145 m2

50 mm thick compacted sand as specified

L To B3A (prov sums) 1 ls

M To B3 252 m2

N To B2 55 m2

O To B1 127 m2

To Collection

INDOOR GARDEN AREA (cont'd)

Cement and sand (1:5) screed as specified

A To receive pebbles stone type 1 at B3 138 m2

B Ditto type 2 at B3 28 m2

C Ditto type 1 at B2 30 m2

D Ditto type 2 at B2 4 m2

E Ditto type 1 at B1 60 m2

F Ditto type 2 at B1 15 m2
50 - 80 mm dia of loose pebbles bedded and
jointed in mortar as specified

G To type 1 at B3 138 m2

H Ditto type 2 at B3 28 m2

I Ditto type 1 at B2 30 m2

J Ditto type 2 at B2 4 m2

K Ditto type 1 at B1 60 m2

L Ditto type 2 at B1 15 m2

Soil Mix

200 mm depth of soil mix as specified

M To receive ground covers at B3A 1 ls

N To receive ground covers type 1 at B3 52 m2

O Ditto type 2 at B3 36 m2

P Ditto type 1 at B2 17 m2

Q Ditto type 2 at B2 4 m2

R Ditto type 1 at B1 43 m2

S Ditto type 2 at B1 10 m2

To Collection

1.6 mm thick of galvanised steel for garden edging


as specified

A To type 1 at B3 79 m

B Ditto type 2 at B3 38 m

C Ditto type 1 at B2 37 m

D Ditto type 2 at B2 5 m

E Ditto type 1 at B1 69 m

F Ditto type 2 at B1 8 m

300 - 500 mm size of lava stone as specified

G To type 2 at B1 1 nos
H To type 1 at B1 10 nos

I To type 2 at B2 1 nos

J To type 1 at B2 5 nos

K To type 1 at B2 12 nos

L To type 2 at B2 3 nos

To Collection

HOTEL ROOF AREA

Floor finishes

Cement and sand (1:5) screed as specified

A 30 mm thick screed to receive stone 760 m2

B 30 mm thick screed to receive pebble wash 145 m2

Paras kelating stone random size bedded and


jointed in mortar

C To floor 760 m2

Pebble wash 20 mm thick grey colour bedded and


jointed in mortar

D To floor 145 m2
To Collection

COLLECTION

Page 6/Sub bill 8.4/18 Rp.

Page 6/Sub bill 8.4/19 Rp.

Page 6/Sub bill 8.4/20 Rp.

Page 6/Sub bill 8.4/21 Rp.

Page 6/Sub bill 8.4/22 Rp.

Page 6/Sub bill 8.4/23 Rp.

Page 6/Sub bill 8.4/24 Rp.

Page 6/Sub bill 8.4/25 Rp.


Page 6/Sub bill 8.4/26 Rp.

Page 6/Sub bill 8.4/27 Rp.

Page 6/Sub bill 8.4/28 Rp.

Page 6/Sub bill 8.4/29 Rp.

SUB BILL NO. 8.4: HARD LANDSCAPING Summary Bill No. 8 Rp.

BILL NO. 8: SITEWORKS

Code Description Quantity Unit

SUMMARY

SUB BILL NO. 8.1: STRUCTURE

SUB BILL NO. 8.2: PLUMBING INSTALLATIONS

SUB BILL NO. 8.3: MINOR BUILDING


SUB BILL NO. 8.4: HARD LANDSCAPING

BILL NO. 8: SITEWORKS To Final Summary

You might also like