TABLE 111.

-SUGGESTED RECORD FORM “A” FOR MEASUREMENTS


OF UPRIGHT CYLINDRICAL TANKS.

Report No.: KAI-CUB-023-2022

Date:. 18/08/2022

Tank No.: 401

Owner’s Name : UNNA ENERGIA SA


Plant or Property Name: BATERIA - 204
Location: LOTE IV
Manufactured by:
Erected by:
Increments
Prepare: Copies: in: Fractions to:
Table Form or Size Desired:
Height: Shell: Gaging:
Type of Roof: Weigh of Floating Roof :
Tank Contents-Name: Avg. Liquid Temp., °F :
Gage (Ft.- in) : Innage To: Shelf Floor or Outage
Hydrometer Reading: at. °F Sample Temperature
Gaging Reference Point to Top of Top Angle (Ft - in.): Normal Service:
Shell Circumferences :
A (Ft.- in): D (Ft.- in): G (Ft.- in):
B (Ft.- in): E (Ft.- in): H (Ft.- in):
C (Ft.- in): F (Ft.- in): J (Ft.- in):

Descriptions of Shell Plates and Joints:

Type of Set, in or Width of Lap Thickness of No. Of Exposed Inside Ring


Ring. # Thickness
Vertical Joint out or Strap Lap or Strap Joints Ring Height Height

7
6
5
4
3
2
1 (Btm.Ring)

Shell Connections:
No. Description Elevation - Top of Floor to Bottom of Consection

1
2
3
4
5
6
Amount of Tank Lean from Vertical (in per Ft.):
Circumference Tape Used: Date Certificate: at.
Tank Measured by: For.
TABLE 111.-SUGGESTED RECORD FORM “A” FOR MEASUREMENTS
OF UPRIGHT CYLINDRICAL TANKS.

Report No.: KAI-CUB-024-2022

Date:. 18/08/2022

Tank No.: 402

Owner’s Name : UNNA ENERGIA SA


Plant or Property Name: BATERIA - 204
Location: LOTE IV
Manufactured by:
Erected by:
Increments
Prepare: Copies: in: Fractions to:
Table Form or Size Desired:
Height: Shell: Gaging:
Type of Roof: Weigh of Floating Roof :
Tank Contents-Name: Avg. Liquid Temp., °F :
Gage (Ft.- in) : Innage To: Shelf Floor or Outage
Hydrometer Reading: at. °F Sample Temperature
Gaging Reference Point to Top of Top Angle (Ft - in.): Normal Service:
Shell Circumferences :
A (Ft.- in): D (Ft.- in): G (Ft.- in):
B (Ft.- in): E (Ft.- in): H (Ft.- in):
C (Ft.- in): F (Ft.- in): J (Ft.- in):

Descriptions of Shell Plates and Joints:

Type of Set, in or Width of Lap Thickness of No. Of Exposed Inside Ring


Ring. # Thickness
Vertical Joint out or Strap Lap or Strap Joints Ring Height Height

7
6
5
4
3
2
1 (Btm.Ring)

Shell Connections:
No. Description Elevation - Top of Floor to Bottom of Consection

1
2
3
4
5
6
Amount of Tank Lean from Vertical (in per Ft.):
Circumference Tape Used: Date Certificate: at.
Tank Measured by: For.
TABLE 111.-SUGGESTED RECORD FORM “A” FOR MEASUREMENTS
OF UPRIGHT CYLINDRICAL TANKS.

Report No.: KAI-CUB-025-2022

Date:. 18/08/2022

Tank No.: 403

Owner’s Name : UNNA ENERGIA SA


Plant or Property Name: BATERIA - 204
Location: LOTE IV
Manufactured by:
Erected by:
Increments
Prepare: Copies: in: Fractions to:
Table Form or Size Desired:
Height: Shell: Gaging:
Type of Roof: Weigh of Floating Roof :
Tank Contents-Name: Avg. Liquid Temp., °F :
Gage (Ft.- in) : Innage To: Shelf Floor or Outage
Hydrometer Reading: at. °F Sample Temperature
Gaging Reference Point to Top of Top Angle (Ft - in.): Normal Service:
Shell Circumferences :
A (Ft.- in): D (Ft.- in): G (Ft.- in):
B (Ft.- in): E (Ft.- in): H (Ft.- in):
C (Ft.- in): F (Ft.- in): J (Ft.- in):

Descriptions of Shell Plates and Joints:

Type of Set, in or Width of Lap Thickness of No. Of Exposed Inside Ring


Ring. # Thickness
Vertical Joint out or Strap Lap or Strap Joints Ring Height Height

7
6
5
4
3
2
1 (Btm.Ring)

Shell Connections:
No. Description Elevation - Top of Floor to Bottom of Consection

1
2
3
4
5
6
Amount of Tank Lean from Vertical (in per Ft.):
Circumference Tape Used: Date Certificate: at.
Tank Measured by: For.
TABLE 111.-SUGGESTED RECORD FORM “A” FOR MEASUREMENTS
REGISTRO DE DIMENSIONAMIENTO DE TANQUE CILINDRICO VERTICAL OF UPRIGHT CYLINDRICAL TANKS.

Report No.: KAI-CUB-026-2022


Date:. 23/08/2022
Tank No.: UNNA - LO4 - P0988

EN
RME CION
Owner’s Name : UNNA ENERGIA SA

O
Plant or Property Name: BATERIA - 204
Location: LOTE IV F
IN BORA
ELA
Manufactured by: N.I.
Erected by: N.I.

Prepare: ING. OSCAR SANCHEZ GUERRERO Copies: 01 Increments in: 1 INCH Fractions to: 1/8"
Table Form or Size Desired: (Ft.)

Height: Shell: 18 Ft. - 5 15/16 inch. (5637 mm) Gaging (Volúmen): 9,409.51 (Ft3) 70,383.14 (Gln) 1,675.79 (Bbls) 266.45 (m3) Altura (Ft.) = 18.49

Diameter Shell: 25.452 Ft.


Type of Roof: TECH FIJO - CONICO Weigh of Floating Roof : N.A. Circunf. (Ft)= 79.96

Tank Contents-Name: AGUA INDUSTRIAL Avg. Liquid Temp., °F (°C): 71.24 °F (21.8°C) Diametro (Ft)= 25.452

Gage (Ft.- in) : Innage To: Shelf Floor or Outage Volumen (Ft3)= 9,409.51

Hydrometer Reading: N.A. at. °F Sample Temperature Volumen (Gln)= 70,383.14


Gaging Reference Point to Top of Top Angle (Ft - in.): INDICADO Normal Service: SISTEMA CONTRA INCENDIO Volumen (Bbls)= 1,675.79

Shell Circumferences : Volumen (m3)= 266.45

A (Ft.- in) - mm: (79 Ft - 11 inch) - 24,358 mm. D (Ft.- in): (79 Ft - 11 inch) - 24,358 mm. G (Ft.- in): N.A.
B (Ft.- in) - mm: (80 Ft - 00 inch) - 24,384 mm. E (Ft.- in): N.A. H (Ft.- in): N.A.
C (Ft.- in) - mm: (80 Ft - 00 inch) - 24,384 mm. F (Ft.- in): N.A. J (Ft.- in): N.A.

Descriptions of Shell Plates and Joints:

Type of Set, in or Width of Lap Thickness of Lap Exposed Ring


Ring. # Thickness No. Of Joints Inside Ring Height
Vertical Joint out or Strap or Strap Height

7
6
5
4
3
2
1 (Btm.Ring)

Shell Connections:
No. Description Elevation - Top of Floor to Bottom of Consection

1
2
3
4
5
6
Amount of Tank Lean from Vertical (in per Ft.):
Circumference Tape Used: Stanley 100 ft. Date Certificate: 8/15/2022 at. 15/8/2023
Tank Measured by: OIL FLUSH SAC. For. Ing. Oscar Sánchez Guerrero