Description
Heading
Company: Heat exchanger
Location: Miami, E.U
Service of Unit: Cooler Our Reference:
Item No.: Your Reference:
Date: 19/10/22 Rev No.: Job No.:
Remarks
Etilenglicol
Application Options
Calculation mode Rating / Checking
Location of hot fluid Shell side
Select geometry based on this dimensional standard SI
Calculation method Advanced method
Application Program
Vaporizer type Set default
Simulation calculation Set default
Thermosiphon circuit calculation Set default
Process Data
Hot Side Cold Side
Fluid name ETILENGL H2O
In Out In Out
Mass flow rate lb/h 10324 5170
Temperature °F 356 100,4
Vapor mass fraction 0 0
Pressure (absolute) psi 14,65 12,95 14,65 11,65
Pressure at liquid surface in column psi
Heat exchanged BTU/h 1488153
Adjust if over-specified Heat load Heat load
Geometry 1
Aspen Exchanger Design and Rating Shell & Tube V10 Page 3
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:43 p. m.
Aspen Exchanger Design and Rating Shell & Tube V10 Page 4
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:43 p. m.
Aspen Exchanger Design and Rating Shell & Tube V10 Page 5
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:43 p. m.
Geometry 2
Aspen Exchanger Design and Rating Shell & Tube V10 Page 6
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:43 p. m.
Aspen Exchanger Design and Rating Shell & Tube V10 Page 7
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:44 p. m.
Geometry 3
Impingement Protection
Impingement protection device None
Impingement plate diameter in
Impingement plate length (parallel to tube axis) in
Impingement plate width (normal to tube axis) in
Impingement plate thickness in
Impingement plate distance in from shell ID in
Impingement plate clearance to tube edge in
Impingement plate perforated area %
Thermosiphon Piping
Pipework loss calculation Set default
Percent of driving head lost in inlet line
Percent of driving head lost in outlet line
Construction Spec
Materials
Cylinder - hot side Carbon Steel
Cylinder - cold side Carbon Steel
Tubesheet Carbon Steel
Double tubesheet (inner) Set Default
Baffles Carbon Steel
Tube material Carbon Steel
Specifications
Design Code ASME Code Sec VIII Div 1
Service class Normal
TEMA class R - refinery service
Material standard ASME
Dimensional standard ANSI - American
Recap of Design
Number of baffles 8 8 8 8
Tube passes 8 8 8 2
Program mode Design (Sizing) Design (Sizing) Rating / Checking Rating / Checking
Advanced Advanced
Calculation method Advanced method Advanced method
method method
Shell ID in 48,2284
Number of baffles 8
Tube passes 2
TEMA Sheet
Overall Summary
Aspen Exchanger Design and Rating Shell & Tube V10 Page 13
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:44 p. m.
Overall Performance
Resistance Distribution
Aspen Exchanger Design and Rating Shell & Tube V10 Page 14
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:44 p. m.
Shell heat load BTU/h 710642 204118 113020 130968 152768 176637
Shell inlet pressure psi 14,65 14,63 14,62 14,6 14,59 14,57
Shell outlet pressure psi 14,63 14,62 14,6 14,59 14,57 14,55
Tube inlet pressure psi 14,59 14,61 14,61 14,61 14,61 14,65
Tube outlet pressure psi 14,53 14,59 14,61 14,61 14,61 14,61
Shell pressure drop psi 0,02 0,02 0,02 0,02 0,02 0,02
Mean shell metal temperature F 296,7 236,33 213,8 193,39 171,2 142,34
Mean tube metal temperature F 215,51 213 200,87 178,45 153,76 122,12
Minimum tube metal temperature F 213,26 209,77 188,15 165,19 135,69 103,44
Maximum tube metal temperature F 218,01 214,21 207,63 188,12 163,17 135,65
Aspen Exchanger Design and Rating Shell & Tube V10 Page 15
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:44 p. m.
Duty Distribution
Aspen Exchanger Design and Rating Shell & Tube V10 Page 16
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:44 p. m.
Pressure Drop
Flow Analysis
Aspen Exchanger Design and Rating Shell & Tube V10 Page 17
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:44 p. m.
Thermosiphons
Thermosiphon stability
Kettles
Recirculation ratio
Quality at top of bundle
Entrainment fraction
Aspen Exchanger Design and Rating Shell & Tube V10 Page 18
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:44 p. m.
Vibration tube location Inlet row, centre Outer window, bottom Baffle overlap Bottom Row
Vibration No No No No
Natural frequency method Exact Solution Exact Solution Exact Solution Exact Solution
Dominant span
Vibration No No
Dominant span
Note: W/Wc = ratio of actual shellside flowrate to critical flowrate for onset of fluid-elastic instability
Vibration tube location Inlet row, centre Outer window, bottom Baffle overlap Bottom Row
Vibration No No No No
Natural frequency method Exact Solution Exact Solution Exact Solution Exact Solution
Dominant span
Vibration No No
Dominant span
Note: W/Wc = ratio of actual shellside flowrate to critical flowrate for onset of fluid-elastic instability
Vibration tube location Inlet row, centre Outer window, bottom Baffle overlap Bottom Row
Vibration No No No No
Natural frequency method Exact Solution Exact Solution Exact Solution Exact Solution
Dominant span
Vibration No No
Dominant span
Note: W/Wc = ratio of actual shellside flowrate to critical flowrate for onset of fluid-elastic instability
Vibration tube location Inlet row, centre Outer window, bottom Baffle overlap Bottom Row
Vibration No No No No
Natural frequency method Exact Solution Exact Solution Exact Solution Exact Solution
Dominant span
Vibration No No
Dominant span
Note: W/Wc = ratio of actual shellside flowrate to critical flowrate for onset of fluid-elastic instability
Vibration tube location Inlet row, centre Outer window, bottom Baffle overlap Bottom Row
Vibration No No No No
Natural frequency method Exact Solution Exact Solution Exact Solution Exact Solution
Dominant span
Vibration No No
Dominant span
Note: W/Wc = ratio of actual shellside flowrate to critical flowrate for onset of fluid-elastic instability
Vibration tube location Inlet row, centre Outer window, bottom Baffle overlap Bottom Row
Vibration No No No No
Natural frequency method Exact Solution Exact Solution Exact Solution Exact Solution
Dominant span
Vibration No No
Dominant span
Note: W/Wc = ratio of actual shellside flowrate to critical flowrate for onset of fluid-elastic instability
Vibration tube location Inlet row, centre Inlet row, centre Inlet row, centre Outer window, bottom
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Outer window, bottom Outer window, bottom Baffle overlap Baffle overlap
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Baffle overlap Bottom Row Bottom Row Bottom Row Inlet row, end
Vibration problem No No No No No
RhoV2 lb/(ft*s2) 0 0 0 0 0
Vibration tube location Inlet row, end Inlet row, end Outer window, top Outer window, top
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration problem No
RhoV2 lb/(ft*s2) 0
Vibration tube location Inlet row, centre Inlet row, centre Inlet row, centre Outer window, bottom
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Outer window, bottom Outer window, bottom Baffle overlap Baffle overlap
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Baffle overlap Bottom Row Bottom Row Bottom Row Inlet row, end
Vibration problem No No No No No
RhoV2 lb/(ft*s2) 0 0 0 0 0
Vibration tube location Inlet row, end Inlet row, end Outer window, top Outer window, top
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration problem No
RhoV2 lb/(ft*s2) 0
Vibration tube location Inlet row, centre Inlet row, centre Inlet row, centre Outer window, bottom
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Outer window, bottom Outer window, bottom Baffle overlap Baffle overlap
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Baffle overlap Bottom Row Bottom Row Bottom Row Inlet row, end
Vibration problem No No No No No
RhoV2 lb/(ft*s2) 0 0 0 0 0
Vibration tube location Inlet row, end Inlet row, end Outer window, top Outer window, top
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration problem No
RhoV2 lb/(ft*s2) 0
Vibration tube location Inlet row, centre Inlet row, centre Inlet row, centre Outer window, bottom
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Outer window, bottom Outer window, bottom Baffle overlap Baffle overlap
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Baffle overlap Bottom Row Bottom Row Bottom Row Inlet row, end
Vibration problem No No No No No
RhoV2 lb/(ft*s2) 0 0 0 0 0
Vibration tube location Inlet row, end Inlet row, end Outer window, top Outer window, top
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration problem No
RhoV2 lb/(ft*s2) 0
Vibration tube location Inlet row, centre Inlet row, centre Inlet row, centre Outer window, bottom
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Outer window, bottom Outer window, bottom Baffle overlap Baffle overlap
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Baffle overlap Bottom Row Bottom Row Bottom Row Inlet row, end
Vibration problem No No No No No
RhoV2 lb/(ft*s2) 0 0 0 0 0
Vibration tube location Inlet row, end Inlet row, end Outer window, top Outer window, top
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration problem No
RhoV2 lb/(ft*s2) 0
Vibration tube location Inlet row, centre Inlet row, centre Inlet row, centre Outer window, bottom
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Outer window, bottom Outer window, bottom Baffle overlap Baffle overlap
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration tube location Baffle overlap Bottom Row Bottom Row Bottom Row Inlet row, end
Vibration problem No No No No No
RhoV2 lb/(ft*s2) 0 0 0 0 0
Vibration tube location Inlet row, end Inlet row, end Outer window, top Outer window, top
Vibration problem No No No No
RhoV2 lb/(ft*s2) 0 0 0 0
Vibration problem No
RhoV2 lb/(ft*s2) 0
Methods Summary
Aspen Exchanger Design and Rating Shell & Tube V10 Page 61
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:45 p. m.
Basic Geometry
Aspen Exchanger Design and Rating Shell & Tube V10 Page 62
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:45 p. m.
Tubes
Aspen Exchanger Design and Rating Shell & Tube V10 Page 63
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:45 p. m.
Baffles
Supports-Misc. Baffles
Aspen Exchanger Design and Rating Shell & Tube V10 Page 64
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:45 p. m.
Bundle
Enhancements
Aspen Exchanger Design and Rating Shell & Tube V10 Page 65
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:45 p. m.
Setting Plan
A
Aspen Exchanger Design and Rating Shell & Tube V10 Page 66
File: C:\Users\HP\OneDrive\Escritorio\ANEXOS\ESTE SI\..\E-304.EDR Printed: 17/10/2022 at 1:43:46 p. m.
Tubesheet Layout
Costs/Weights