You are on page 1of 4

TUBE DIMENSION REPORT

CLIENT : BARC DATE : 20/08/2021


W. O. No.: 17-185 EQPT. No. : 109CHF010001

INSPECTION AGENCY : TUV PAGE: 1 OF 1

DRG. No. : SDB/E/182396B REV.0 PART NO. - 301


TUBE OD AND TUBE ID BOTTOM- SIDE

TUBE NO. TUBE OD TUBE ID TUBE NO. TUBE OD TUBE ID TUBE NO. TUBE OD TUBE ID

1 19.01 14.55 24 19.01 14.56 47 19.00 14.58


2 19.05 14.56 25 19.00 14.58 48 19.04 14.56
3 19.05 14.56 26 18.99 14.51 49 19.02 14.70
4 19.01 14.58 27 19.04 14.54 50 18.96 14.58
5 18.99 14.56 28 19.05 14.62 51 19.08 14.56
6 19.04 14.60 29 19.04 14.61 52 19.05 14.55
7 18.99 14.56 30 19.05 14.50 53 19.09 14.58
8 19.08 14.58 31 19.10 14.58 54 19.05 14.57
9 19.01 14.56 32 19.05 14.49 55 19.05 14.60
10 19.00 14.53 33 18.95 14.55 56 19.10 14.56
11 19.06 14.58 34 19.05 14.55 57 19.05 14.59
12 19.07 14.59 35 19.05 14.60 58

13 19.05 14.57 36 19.05 14.57 59


14 19.09 14.60 37 19.01 14.59 60

15 19.05 14.56 38 19.03 14.55 61

16 19.03 14.59 39 19.05 14.55 62

17 19.05 14.55 40 19.06 14.62 63

18 19.07 14.59 41 18.98 14.60 64

19 19.05 14.59 42 19.04 14.59 65

20 19.11 14.58 43 19.03 14.56 66

21 19.05 14.56 44 19.01 14.54 67

22 19.08 14.57 45 19.03 14.57 68

23 19.05 14.55 46 19.05 14.54 69

Remark : ACCEPTED
NOTE : (1) TUBE OD 19.05 ( -0.11,+0.1)
(2) PR/TA/183 ( INSIDE MICROMETER ) Due Date : 22.12.2022
(3) QC/TA/007 ( OUTSIDE MICROMETER ) Due Date : 30.07.2022

Inspected By : TEMA INDIA LTD Inspected By :

Signature : Signature :

Name :DARPAN KANSARA Name :

Date : Date :
Name :DARPAN KANSARA Name :

Date : Date :
TUBE DIMENSION REPORT

CLIENT : BARC DATE : 20/08/2021


W. O. No.: 17-185 EQPT. No. : 109CHF010001

INSPECTION AGENCY : TUV PAGE: 1 OF 1

DRG. No. : SDB/E/182396B REV.0 PART NO. - 301


TUBE OD AND TUBE ID BOTTOM- SIDE

TUBE NO. TUBE OD TUBE ID TUBE NO. TUBE OD TUBE ID TUBE NO. TUBE OD TUBE ID

1 24 47

2 25 48

3 26 49

4 27 50

5 28

6 29

7 30

8 31

9 32

10 33

11 34

12 35

13 36
14 37

15 38

16 39

17 40

18 41

19 42

20 43

21 44

22 45

23 46

Remark : ACCEPTED
NOTE : (1) TUBE OD 19.05 ( -0.11,+0.1)
(2) PR/TA/183 ( INSIDE MICROMETER ) Due Date : 22.12.2022
(3) QC/TA/007 ( OUTSIDE MICROMETER ) Due Date : 30.07.2022

Inspected By : TEMA INDIA LTD Inspected By :

Signature : Signature :

Name :DARPAN KANSARA Name :

Date : Date :
Name :DARPAN KANSARA Name :

Date : Date :