Bridge travel and trolley traversing are performed with a three-phase induction motor with squirrel
cage, with separate braking group.
Page 54
55
Page 55
56
6.16.2. For instructions on how to regulate air gap, brake torque and
how to replace the brake, see the attachments
Page 56
57
At start-up:
ATTENTION! Crane power must be on in order to perform the following operations. Therefore, the
emergency radio remote control must be kept at hand’s reach for the maintenance
operator and nobody else, in order to prevent dangerous manoeuvres and to timely
act on controls and on the stop button. See § 6.3 GENERAL NOTES for safety
prescriptions.
1. Mark a visible reference point on the rail (see figure 6.12 – point 1) in a safe place, far from end stops and
the edges of the limit switches.
2. Make the bridge and trolley move at maximum speed and full load. Make sure the trolley is halfway form
the heads. Push the stop button when the front wheel is aligned with the marked reference (see Figure
6.12).
3. Measure the breaking distance with load x2 (see Figure ).
4. Regulate the brake making sure that x2 is lower than 1 m. Given D as the distance of the limit switches’
edges and the end stops (see figure 6.12), it should be: D > x2 + 400 mm. For the bridge brakes, repeat
the regulation for both motors, so that braking is regular and parallel and that breaking distance is the
same for both sides.
5. Mark down the x2 value, corresponding to the calibration made.
6. Repeat measure on point 2 without load.
7. Measure braking distance without load x1 (see Figure 6.12) and mark down the value.
x1
Punto
Point 1 1
x2
x3
Figure 6.12
Attuatore limitatore
Load limiter actuator di End Stopdi estremità
Arresto
arresto
Figure 6.13
Page 57
58
The gearbox installed on the hoist group is provided with spur gears with parallel shafts in watertight
case. Closing cap is provided with a pressure safety valve to let the gases produced inside the case
out.
Standard lubrication is carried out with ISO VG 220 oil (see also § 6.2 INDICATIONS ON
LUBRICANTS).
At start-up, after three months and, subsequently, every 12 months. Check bolts tightening and relative
crushing of the anti-vibration bushing (equal to 1.5 mm max)
• Check the oil level in the gearbox. Top it up, if necessary
• Make sure the venting cap is not obstructed.
Every 60 months:
• Change the oil if gearboxes are lubricated with mineral oil.
• ATTENTION! Dispose of waste oil responsibly after use!
Page 58