SHEET
STATE PROJECT
L L NUMBER
PROJECT NUMBER
OUTLET WITHOUT DITCH ST
PROJECT NAME
3 3
1
PROTECTIVE APRON DIMENSIONS AND ESTIMATED QUANTITIES
1
LENGTH DEPTH
CULVERT ESTIMATED ESTIMATED
OF OF
SIZE RIPRAP RIPRAP GEOTEXTILE
D
A APRON
D
A B B APRON
D CLASS QUANTITY QUANTITY
L
Dia. or
H
Dia. or
(CY) (SY) NOTE:
Span
Span
(inches) (feet) (feet)
D
1. Use for aprons serving culverts with
12 2 4 1.5 1 5
slopes of less than 10%.
18 2 6 1.5 2.2 9
D
D
24 2 8 1.5 3.9 14 2. Furnish geotextile filter conforming to
2'(min.) WITH 30 3 12.5 2 10.9 28 subsection 714.01(a). See summary
1 END tables for class and type.
1 36 3 16 2 15.6 37
3 SECTION
3 42 4 21 2.5 34.1 63 3. Excavation for placement of riprap will
PLAN VIEW PLAN VIEW 48 4 24 2.5 44.5 79 not be measured for payment.
12 2 6 1.5 1.7 8
CULVERT WITH STANDARD CULVERT WITHOUT STANDARD
END SECTION 18 2 8 1.5 3.2 12
END SECTION
24 2 10 1.5 5.2 17
WITHOUT 30 3 14.5 2 13.3 33
END
36 3 17 2 18.5 43
Original SECTION
Original ground 42 4 23 2.5 38.7 70
ground
48 4 26 2.5 49.8 87
Variable slope
(min.)
Variable slope
(min.)
H
H
Geotextile filter
Geotextile filter See note 2
See note 2
3D
2
2
D D E E 12 2 4 1.5 0.9 5
Ditch Bottom
Ditch Bottom
Dia. or
Dia. or
18 2 6 1.5 2 8
Width
Width
Span
Span
2D
2D
D
D
24 2 8 1.5 3.6 13
WITH 30 3 12.5 2 9.3 24
END
3D
3D
36 3 15 2 13.4 32
2
2
[C251-50]
SECTION
42 4 21 2.5 27.3 53
48 4 24 2.5 35.6 65
2'(min.)
K:\CADD_Coordinator\ORD Drawings\Details\C251-50.dgn
C C 12 2 6 1.5 1.4 6
24 2 10 1.5 4.5 15
WITHOUT 30 3 14.5 2 10.8 27
CULVERT WITH STANDARD CULVERT WITHOUT STANDARD END
36 3 17 2 15.2 36
END SECTION END SECTION SECTION
42 4 23 2.5 29.9 57
48 4 26 2.5 38.6 70
4D
Sloped 1V:2H Original
Original Original
or flatter ground
ground ground
(min.) (min.)
(min.) (min.)
ditch slope
D
ditch slope
D
2
2
1
1
(min.)
Geotextile filter
D
See note 2
U.S. DEPARTMENT OF TRANSPORTATION
2
H
1
H
CENTRAL FEDERAL LANDS HIGHWAY DIVISION
Flowline
Geotextile filter Geotextile filter CFLHD DETAIL
9:17 AM
AT CULVERT OUTLETS
PROTECTIVE APRON AT CULVERT OUTLET
NO SCALE
WITH DITCH DETAIL APPROVED FOR USE
DETAIL
REVISED: 08/2014 08/2020 09/2021
C251-50