Analysis & Compressive Strength Study of Eco-Friendly Concrete by Partial Replacement of Recycle Brick with
Over-Burnt Brick Aggregate
indicate that crushed over burnt bricks – sand concrete is coarse aggregate ratios 20%,40%, 60% and 80% in M40
medium light weight concrete having a density between grade of concrete. It is observed that workability decreased
2000-2200 kg/m3 and compressive strength of up to 29.5 with the replacement of coarse aggregate. The Compaction
N/mm2 compared to grave l –sand concrete having a density factor observed as 0.92,0.899,0.88,0.87 and 0.85 with
between 2300-2400 kg/m3 and compressive strength of up varying percentage replacement of coarse aggregate by
to 30.8 N/mm2. It was concluded that by reducing the Jhama class brick bat as 0%, 20%,40%,60% and 80%
water-cement ratio from 0.60 to 0.40 the compressive respectively. The compressive strength of Jhama Class
strength of crushed over burnt bricks – sand concrete and Brick bat-based concrete used with partially replacement
gravel – sand concrete increased by more than 30%. Use of Jhama class brick to coarse aggregate ratios 20%, 40%,
broken over burnt bricks as coarse aggregate for structural increased over conventional concrete about 6.08%, 10.02%
concrete was recommended when natural aggregate was not for 3 days and 9.23%, 12.08% for 7 days and 10.02%,
easily available, high strength of concrete was not required 11.95% for 28 days. If further increased in the percentage of
and the bearing capacity of the soil was low. replacement up to 60% and 80%, the strength was decreased
by 3.73% and 8.16% respectively for 3 days and 5.69%,
9.25% for 7 days and 2.72%, 6.87% for 28 days cured cube
specimen respectively. The Split Tensile and Flexural
Strength of this concrete increases with 5.26%, 8.68%, and
2.74%, 4.76% respectively over plain concrete for the
replacement 20% and 40% and decreased with 3.94%,
12.1% and 3.16%, 7.5% for the replacement 60% and 80%.
General-
95
International Journal of Engineering Research in Current Trends (IJERCT)
ISSN: 2582-5488, Volume-3 Issue-4, July 2021
The broken stone is generally used as a coarse aggregate. A slump test can be used to measure the workability of
The nature of work decides the maximum size of the coarse concrete. Immediately after mixing each batch of concrete
aggregate. Locally available coarse aggregate having the should be tested for consistency by one of the techniques
maximum size of 20 mm was used in our work. The
indicated in IS: 1199-1959.
aggregates were washed to remove dust and dirt and were
dried to surface dry condition. The aggregates were tested as
per Indian Standard Specifications IS: 383-1970. TABLE IV: TEST OF WORKABILITY OF CONCRETE
96
Analysis & Compressive Strength Study of Eco-Friendly Concrete by Partial Replacement of Recycle Brick with
Over-Burnt Brick Aggregate
V. CONCLUSION
97
International Journal of Engineering Research in Current Trends (IJERCT)
ISSN: 2582-5488, Volume-3 Issue-4, July 2021
REFERENCE
[1] Tariq Ali, Nouman Iqbal, Md Zeeshan, Md Zulfiqar Ali Khan,
Evaluation of the Compressive strength of Concrete for partial
replacement of Over Burnt Brick Ballast Aggregate, International
Journal of Science and Modern Engineering (IJISME), December
2013.
[2] G. S. Patil and P. B. Autade, “Effect of Partial Replacement of Coarse
Aggregate by Jhama Class Brick in Concrete, International Journal of
Engineering Research and General Science, Volume 3, Issue 4, Part-
2, July-August, 2015 ISSN 2091-2730.
[3] Apebo N. S., Agunwamba J. C., Ezeokonkwo, J. C” The suitability of
crushed over burnt bricks as coarse aggregates for concrete”
International Journal of Engineering Science and Innovative
Technology (IJESIT), Volume 3, Issue 1, January 2014.
[4] “Concrete Technology” Theory and practice, A text book by
M.S.Shetty, 2005.
[5] Punamia B.C., “R.C.C. Designs”, Laxmi publications (P) Ltd, New