You are on page 1of 7

DATA SHEET RESP005D-DM

SEALLESS CENTRIFUGAL PUMPS PAGE 2 OF 5

rev. (METRIC UNITS) JANUARY 2017


A2 ISSUED FOR: PROPOSAL X PURCHASE AS BUILT
FACILITY NAME/LOCATION: MdA EXPANSION PROGRAM - LOS PATOS OSBL, MINERA DEL ALTIPLANO, ARGENTINA
A2 ITEM NAME: NaCl BRINE FEED PUMPS PURCHASER/LOCATION: WOOD PLC, FOSTER WHEELER (HEBIE)
A2 ITEM TAG NO.: P-2232/33-1 JOB NO.: 2598
SERVICE: SODIUM CHLORIDE 26%WT PURCHASER ORDER NO.:
A2 UNIT: OSBL BRINE PLANT SUPPLIER/LOCATION: MOSINE MACHINARY & ENGINEERING (SHANGHAI)

P&ID NO.: 220-PI-027 - H1 SUPPLIER ORDER/SERIAL NOS.: VTA / VTA

DATA PROVIDED BY: PURCHASER SUPPLIER SUPPLIER IF NOT BY PURCHASER


GENERAL
A2 NO. REQ.: 2 u PUMP SIZE: A1-1.5x1x6-TBM (1 stage) u TYPE: HORIZONTAL
NUMBER MOTOR DRIVEN: 2 NUMBER TURBINE DRIVEN: N/A
MOTOR ITEM NUMBER: N/A TURBINE ITEM NUMBER N/A GEARBOX ITEM NUMBER: N/A
MOTOR PROVIDED BY: SUPPLIER TURBINE PROVIDED BY: N/A GEARBOX PROVIDED BY: N/A
MOTOR MOUNTED BY: SUPPLIER TURBINE MOUNTED BY: N/A GEARBOX MOUNTED BY: N/A
OPERATING CONDITIONS PERFORMANCE
RATED MAX. NORMAL MIN. PERFORMANCE CURVE NO.: VTA
A2 CAPACITY: (Note 13) 7.9 N/A N/A VTA M3/H MEASURED AT CAPACITY:
SUCTION PRESSURE: -0.201 N/A N/A N/A BARG RATED MAX. NORMAL MIN.
A2 DISCHARGE PRESSURE: 2.311 N/A N/A N/A BARG ROTOR: 2,900 RPM
A2 DIFFERENTIAL PRESSURE: 2.511 BAR IMPELLER DIAMETER: 131 169 102 cm.
A2 DIFFERENTIAL HEAD: 21.33 M @ NORMAL S.G. NPSH REQ’D: 0.7 M
A2 HYDRAULIC POWER 0.55 KW EFFICIENCY: 48.3 56.6 %
A2 AT DESIGNATED CAPACITY: RATED MAX. NORMAL MIN. HYDRAULIC: 0.55 KW
OPERATING TIME: N/A N/A N/A N/A % MAGNETIC: VTA KW
A2 NPSH AVAILABLE: 3.4 N/A N/A N/A M TOTAL: KW
SYSTEM DESIGN:
A2 X STAND ALONE OPERATION PARALLEL OPERATION SUCTION SPECIFIC SPEED: 9,375 (metric)
A2 SERIES OPERATION WITH ITEM NUMBER: BEST EFFICIENCY POINT FOR RATED IMPELLER: 14.0 M3/H
SERVICE: MINIMUM CONTINUOUS FLOW WITHOUT EXTERNAL FLUSHING:
A2 CONTINUOUS X INTERMITTENT: 6 STARTS/DAY THERMAL: M3/H STABLE: 0.2 M3/H
SYSTEM CONTROL METHOD: MINIMUM CONTINUOUS FLOW WITH EXTERNAL FLUSHING:
A2 SPEED X FLOW LEVEL TEMPERATURE THERMAL: M3/H STABLE: 2.2 M3/H
A2 PRESSURE PIPE FRICTION RESISTANCE ONLY MAX. DIFFERENTIAL HEAD @ RATED IMPELLER: 22.42 M

PUMPED FLUID SITE CONDITIONS


PUMPED FLUID: SODIUM CHLORIDE 26%WT LOCATION:
RATED MAX. NORMAL MIN. X INDOOR HEATED UNDER ROOF
A2 PUMPING TEMP.: N/A 18 15 N/A °C OUTOOR UNHEATED PARTIAL SIDES
AT DESIGNATED TEMP.: ALTITUDE: 3978 M. ASL
SPECIFIC GRAVITY: N/A N/A 1.2 N/A RANGE OF AMBIENT TEMPS. MIN./MAX.: -20 / 20 °C
VAPOR PRESSURE: N/A N/A 0.02 N/A BARA ELECTRICAL CLASSIFICATION:
VISCOSITY: N/A N/A 3 N/A CP CL.: N/A GR.: N/A DIV.: N/A
SPECIFIC HEAT: N/A N/A 3.4 N/A KCAL/KG°C X NON HAZARDOUS TEMP. CODE:
VAPOR PRESSURE VS TEMPERATURE CURVE PROVIDED GENERAL REMARKS
LIQUID: HAZARDOUS FLAMMABLE 1.) Estimated considering minimum level in the tank: 1524 mm,
CORROSIVE / EROSIVE AGENT: Sodium Chloride 26%wt Pressure drop in filter (F-2236-1) at suction line: 0.3 bar
CHLORIDE CONCENTRATION: N/A PPM
H2S CONCENTRATION: N/A PPM
OTHER: N/A
% SOLIDS: N/A MAX. PARTICLE SIZE: N/A mm.

NO. DATE REVISION DESCRIPTION BY APVD.


A1 10-May-2021
A2 25-Jun-2021

X
DATA SHEET RESP005D-DM

SEALLESS CENTRIFUGAL PUMPS PAGE 3 OF 5

rev. (METRIC UNITS) JANUARY 2017


MAGNETIC DRIVE PUMPS u MOTOR DRIVER
A2 X MAGNETIC COUPLING MANUFACTURER: WEG
A2 EDDY CURRENT HORSEPOWER: 3 SPEED: 3000 RPM
A2 SOFT START REQUIRED 100LFRAME: ENCLOSURE: TEFC
A2 MAGNET SIZED TO HANDLE: (Note 11) TYPE: Induction SERVICE FACTOR: 1.0
A2 RATED CAPACITY X BEP FULL LOCKED MOTOR TORQUE REMARKS: Note 3
CONTAINMENT SHELL:

RADIAL CLEARANCE TO OUTER MAGNET RING: VTA mm. u MECHANICAL DATA


RADIAL CLEARANCE TO INNER ROTOR: VTA mm. PUMP MUST MEET ASME B73.3 DIMENSIONAL REQUIREMENTS:
MAGNET & BEARING FLUSHING (INT. / EXT.): VTA X YES NO
EDDY CURRENT LOSSES THROUGH SHELL: VTA KW NOZZLE CONNECTIONS:
HEAT GENERATION IN THE SHELL: VTA Cal./H. SIZE CLASS TYPE FACING
A2 DECOUPLE TORQUE: VTA N-cm. SAFETY FACTOR: VTA SUCTION: 1 1/2" 150# B16.5 RF
A2 LOCKED ROTOR TORQUE: 20.3 N-m. DISCHARGE: 1" 150# B16.5 RF
A2 OUTER INNER DRAIN: 3/8" NPT
A2 MOUNTING METHOD: Integral Integral VENT: N/A N/A N/A N/A
A2 TEMP. LIMITATION: 121 121 °C IMPELLER TYPE:
A2 HERMETICALLY SEALED: Yes Yes X CLOSED OPEN SEMI-OPEN
NUMBER OF MAGNETS: OTHER:
TOTAL TORQUE: N-m. CASING MOUNTING:
EXTERNAL ROTOR BEARINGS: X FOOT CENTERLINE VERTICAL IN-LINE
u MANUFACTURER: CONTAINMENT SHELL / STATOR LINER PRESSURE RATING:
COUPLING END BEARING TYPE / NO.: MAX. ALLOWABLE WORKING PRESSURE: VTA BARG VTA °C
IMPELLER END BEARING TYPE / NO.: HYDROSTATIC TEST PRESSURE: 1.5 x MAWP BARG
LUBRICATION: GREASE FLOOD CONSTANT LEVEL OILER PAINT AND SHIPMENT PREPARATION
SHIELDED (GREASE) SEALED (GREASE) PUMP: BASEPLATE:
PURE MIST PURGE MIST MANUFACTURER’S STD. X MANUFACTURER’S STD.
BEARING ISOLATORS (MFG/TYPE) X OTHER: CES6100P, 6101P OTHER:
OIL VISCOSITY ISO GRADE: SHIPMENT:
A2 COUPLING: (Close-coupled design) DOMESTIC EXPORT X EXPORT BOXING REQ'D.
MANUFACTURER: TYPE: NUMBER OF MONTHS OF STORAGE: 12
SIZE: MODEL: TOTAL WEIGHT: VTA KG.
SPACER LENGTH: cm. INSPECTION AND TESTING
A2 u COUPLING GUARD: MANUFACTURER’S STANDARD X FINAL INSPECTION REQUIRED
NON-SPARK COUPLING GUARD REQUIRED X DAYS NOTIFICATION REQUIRED: 10
MATERIAL IF NOT SPECIFIED BY PURCHASER: TEST NON.-WITNESSED WITNESSED CERTIFICATE
REMARKS: Note 1 HYDROSTATIC: X
A2 CANNED MOTOR PUMPS PERFORMANCE: X
SOFT START REQ’D NPSHR:
A2 STATOR LINER: SECONDARY CONTAINMENT TO FULL PRESSURE VIBRATION: X
RATING REQUIRED OTHER:
RADIAL CLEARANCE TO ROTOR: mm. DISMANTLE AND INSPECT AFTER TEST
u LINER TO CASING SEALING METHOD: X CASTING REPAIR PROCEDURE APPROVAL REQUIRED
SEAL WELDED OTHER: MATERIAL CERTIFICATION REQUIRED:
HEAT GENERATION IN THE LINER: Cal./Hr. CASING COVER IMPELLER SHAFT
LOCKED ROTOR TORQUE: N-cm. OTHER:
u STATOR CAVITY: INSPECTION REQUIRED FOR CONNECTION WELDS:
DRY OIL FILLED OTHER: X MANUFACTURER’S STANDARD NDT INSPECTION
ROTOR BEARINGS: INSPECTION REQUIRED FOR CASTINGS:
IMPELLER END BEARING TYPE: X MANUFACTURER’S STANDARD NDT INSPECTION
OUTBOARD END BEARING TYPE: OTHER:
MOUNTING METHOD: MANUFACTURER DOCUMENTATION REQUIREMENTS
ASME BASE PLATE SOLE PLATE OTHER FOR DATA REQUIREMENTS REFER TO: Material Requisition
REMARKS: REMARKS:
DATA SHEET RESP005D-DM

SEALLESS CENTRIFUGAL PUMPS PAGE 4 OF 5

rev. (METRIC UNITS) JANUARY 2017


u COOLING OR HEATING PIPING INSTRUMENTATION
NAME OF FLUID: N/A LEAK DETECTOR – SECONDARY CONTAINMENT BY:
INLET TEMPERATURE: N/A °C PURCHASER SUPPLIER
OUTLET TEMPERATURE: N/A °C u MAKE / MODEL:
RATED FLOW: N/A M3/H VIBRATION MONITORING BY:
SUPPLY PRESSURE: N/A BARG PURCHASER SUPPLIER
MAX. ALLOWABLE ΔP: N/A BAR u MAKE / MODEL:
GALVANIZED PIPE STAINLESS STEEL TUBING MOTOR LOAD PROTECTION BY:
A2 SIGHT FLOW INDICATOR PURCHASER X SUPPLIER
A2 OUTLET SHUT-OFF VALVE u MAKE / MODEL: Emotron M20/380-500V w/CT 0.1-10amps
A2 REMARKS: Note 10 X MINIMUM FLOW BYPASS PROVIDED BY PURCHASER
u TEMPERATURE & PRESSURE:
TEMPERATURE GAUGES
u PIPING PLANS: ASME B73.3 X THERMOWELLS
HEATING AND COOLING PIPING PLAN: N/A PRESSURE GAUGES
PUMP FLUID CIRCULATION PLAN: N/A CONTAINMENT SHELL TEMPERATURE PROBES ONLY
CANNED MOTOR WINDING THERMOSTATS
u MATERIALS BEARING WEAR INDICATOR
A2 MATERIAL CLASS CODE: N/A OTHER: Note 12
A2 CASING: Ductile Iron lined with ETFE
A2 IMPELLER: CF-ETFE
A2 CASE / IMPELLER WEAR RINGS: SiC / SiC
A2 SHAFT: SiC
A2 CONTAINMENT SHELL: CF-ETFE/Aramid Fiber
A2 STATOR LINER: N/A
A2 MAGNET (OUTER DRIVE RING): NdFeB
A2 INNER ROTOR: CF-ETFE
A2 SLEEVE BEARING: SiC
A2 THRUST BEARING: SiC
A2 DRIVER BEARING HOUSING: N/A
A2 WETTED FASTENERS: N/A
A2 BASEPLATE: Carbon Steel
A2 COUPLING GUARD: N/A
A2 ELECTRICAL PENETRATION SEALANT: N/A
A2 REMARKS: Casing gasket/: FEP with fully encapsulated FKM core
DATASHEET RESP005D-DM

SEALLESS CENTRIFUGAL PUMPS PAGE 5 OF 5

rev. (METRIC UNITS) JANUARY 2017


1
2 NOTES;
3
4 1 Magnetic Sealless Centrifugal Pump shall be designed according to Specification for Magnetically Driven Centrifugal Pumps (CES 0325)
5 and ASME B73.3.
6 2 Pump design life shall be 20-30 years as minimum and at least 5 years of uninterrupted operation, there shall be no pump failures for a
7 minimum of 5 years.
8 3 Driver power shall, as a minimum, be equal to the rated shaft power at the rated point multiplied by the percentage as below;
9
10 Motor Nameplate Rating (hp) Percent of Rated Pump Power
11 5 and less 150
12 5 to 25 125
13 26 to 75 115
14 Over 75 110
15
16 4 NPSH test are required if the required NPSH does not meet the requirement below;
17
18 NPSH required NPSHa must exceed NPSHr by at least
19 less than 10 ft 2 ft
20 10 ft thru 15 ft 3 ft
21 Greater than 15 ft 4 ft
22
23 5 Utility and ambient data as per Project Data.
24 6 Any wetted parts shall be made of corrosive resistant material.
A2 25 7 DELETED.
26 8 Two (2) diagonally opposite earthing bosses on pump baseplate shall be provided.
A2 27 9 DELETED.
28 10 Pump shall be designed to operate without water-cooling.
29 11 Magnet drive systems shall be designed to transmit the rated power and torque of the selected pump frame using the maximum impeller
30 diameter, end of curve capacity and a specific gravity of 1.15 without slippage.
31 12 The thermowell with PT 100 installed in the casing drain connection shall be provided to measure containment shell temperature.
A2 32 13 Rated flow 7.9 m3/h is 5.9 m3/h forward flow plus 2.2 m3/h continuous recirculation flow.
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47 ABBREVIATION
48 TBA = To be Advised
49 TBC = To be Confirmed
50 VTA = Vendor to advise
51 VTC = Vendor to confirm
52 N/A = Not Applicable
53 DEC = Detailed Engineering Contractor
54
55
PAGE 1 of 2
MdA EXPANSION PHASE 1 PROJECT DATA SHEET REVISION: A2
DOCUMENT NO: 24110-8470-DS-P2232-1
CLIENT: LIVENT CORPORATION REQN. NO: TBC
CONTRACT: 2598 MODEL / TYPE: PN#Z00330ET3J021020; SAP# 15339251
Mineral Del Altiplano,
SERVICE: LV MOTOR FOR NaCl BRINE FEED PUMPS (P-2232/33-1) TAG NO. P-2232/33-1 LOCATION:
Argentina

rev. MOTOR- REQUIREMENTS AND CONDITIONS


QUANTITY No Off 2 Basic Data (cont'd...)
SITE CONDITIONS Winding Temp. Monitoring:  Yes x No
Ambient Temperature: (Note 7) Type :  RTD's  Thermister
MAX / MIN / DESIGN- °C 20 / -20 / -20 No. per Phase  Two  Other
Humidity 20-30% Thermocouples Req.:  Yes x No
Altitude 3978 metres Bearing Temp. Monitoring:  Yes x No
Area Classification:- x N/A  ZONE 2  ZONE 1 Type :
Temperature Class:- x N/A  T3  Other T __ No. per Winding  One  Other
Gas Group:- x N/A  IIB  Other II__ Thermocouples Req.:  Yes x No
Type of Protection:- x N/A  EExe  EExde Vibrameter  Yes x No
BASIC DATA No. per bearing:
Supply System x 400 V  380 V : ± 5% / 3 Ph. / 50 Hz ± 2% No. per casing  One  Other
Neutral:  Unearthed x 400 V
Resistance Earthed (100 Ohm) Differential CT's:  Yes x No
 Solidly Earthed Ratio:- N/A Accuracy Class:- N/A
Prospective System Fault Current:- 100 kA (At Switchgear) CT Arrangement: N/A
Motor Voltage  400 V x 380 V : ± 5% / 3 Ph. / 50 Hz ± 2%  Scheme 1
CT's CT
Cooling method: TEFC (IC411)
A2 Degree of Enclosure Protection:- IP 55  Scheme 2
Continuous Rating:- 3 kW (Note 2) M M M
Duty Type S1 Service factor 1  Scheme 3 CT's

A2 Synchronous Speed:- 3,000 RPM Scheme 1 Scheme 2 Scheme 3

Insulation Class F Temp. Rise Class B Cable Type: Motor:- TBA


(Note 1) Heater:- N/A
A2 Direction of Rotation:-  CW  CCW x Bi-Dir. Winding RTD:- N/A
(viewed from non-drive end) Bearing Sensor:- N/A
Method of Starting:- x DIRECT ON LINE  Other _____ CT N/A
Max LRC/FLC ratio %  600 x Other (Note 4)
Winding Connection:  Star x Delta

Outline Drawing (V.P. No.)

Mounting: x Horizontal  Vertical


Slide Rails Required  Yes  No
Heater Required: (Note 3)  Yes x No Motor Starter Protective System: (supplied by other)
Heater Voltage:- 220 V 1 ph ac  Fuses/Contactor x MCCB / Contactor
Drain Required:  Yes  No x Overload  Earth Fault > 30kW
Breather Required:  Yes  No x Undercurrent x Phase Unbalance
Terminal Box Type :- x N/A  EExe  EExd x Undervoltage x Stall

Bearing Type: x Ball/ Roller  Sleeve


Lubrication:  Oil (self containing) x Grease Surge Protection Required:  Yes x No

LOCATION OF TERMINAL BOX AND ENTRY (See Motor List) MAIN TERMINAL BOX
CABLE TERMINAL BOX CABLE SERIAL
E
B TAG NO Position Tapping SIZE NUMBER
D
w w Power A (Note 6) Y TBA
C A z
x z x
y
y

AUXILIARY TERMINAL BOX(ES)


CABLE TERMINAL BOX CABLE SERIAL
VIEW ON SIDE VIEW VERTICAL TAG NO Position Tapping SIZE NUMBER
NON-DRIVE END SPINDLE
Heater N/A N/A N/A
ABBREVIATIONS Winding RTD N/A N/A N/A

TEFC - Totally Enclosed Fan Cooled


MCCB - Molded Case Circuit Breaker
NOTES
A2 VTA - Vendor to advise during Detail Engineering 1) All cable connections shall be suitable with conduit coupling, provided by
TBA - To be advised later (by purchaser) others
TBC - To be confirmed 2) Motor rating & frame size shall be suitable to derating factor due to high
altitude
3) Anti condensation heaters shall be provided for LV motor outdoor location
only.
4) Per IEC 60034-12
5) Motor efficiency shall be supplied at least IE3 according to IEC 60034-30-1
6) Auxiliary terminal box is preferred at the same side as the main power
terminal box; however it can be located in opposite side if it cannot be located
on the same side as the power terminal box.
7) For Indoor condition, minimum design Temperature is 5°C and maximum
design Temperature is 26 °C per Attachment-2 of MR.
PAGE 2 of 2
MdA EXPANSION PHASE 1 PROJECT DATA SHEET REVISION: A2
DOCUMENT NO: 24110-8470-DS-P2232-1
CLIENT: LIVENT CORPORATION REQN. NO: TBC
CONTRACT: 2598 MODEL / TYPE: PN#Z00330ET3J021020; SAP# 15339251
Mineral Del Altiplano,
SERVICE: LV MOTOR FOR NaCl BRINE FEED PUMPS (P-2232/33-1) TAG NO. P-2232/33-1 LOCATION:
Argentina

rev. LV MOTOR
DATA TO BE COMPLETED BY SUPPLIER
Standard:  BS x IEC  NEMA  VDE  Other:-
ELECTRICAL DETAILS MECHANICAL DETAILS
Frame Ref. No.:- Construction
Model/Cat. No.:- No Of Poles
Outline Dimension Dwg. No.:- No of Stator Slots
Speed at Full Load:- rpm Rotation (NDE)  CW  CCW  Bi
Full Load Current (FLC):- A
Starting Current:- (locked rotor ) 100%/80% rated volts % FLC Bearing Type:  Ball  Roller  Sleeve
Efficiency (100/75/50%):- (Note 5) / / % Make & Ref No. (DE):
Power Factor (100/75/50%):- / / % Make & Ref No. (NDE):
Power Factor (Starting):- Lubrication:  Oil (self containing) x Grease
Full Load Torque (FLT):- Cooling System:- Type
Starting Torque:- (locked rotor ) 100%/80% rated volts / % FLT Rotor End float:- +6 mm; mm
Minimum Accel. Torque (Motor & Load):- 100%/80% V / % FLT Rotor End-Play:- mm
Pull-Out Torque:- % FLT Rotor Air Gap:- mm
Locked Rotor Withstand Time: 100% V:- Hot:- s Cold:- s Moment of Inertia GD² (Motor & Load):- kgm²
80% V:- Hot:- s Cold:- s H Factor:- MW-s/MVA
Run-Up Time (Motor & Load) 100% V:- Hot:- s Cold:- s Weight of Motor:- kg
80% V:- Hot:- s Cold:- s Noise Level:- ≤ 85 dB(A) @ 1 m
Insulation Class & Temp Rise above Design Ambient:- F /By resistance

Max. No. of Starts in . 1 .hour .. equally spaced COOLING


Maximum No. of Successive Starts:- ..from hot .. from cold
A2 Starting time 100% / 80 % Volt : / Cooling Method x TEFC  IC6A1A1  Other
Locked Rotor Impedance @ 20 °C :- = ohms +/- % tolerance Motor Air Cooler Rating N/A kW rating
Locked Rotor Reactance @ 20 °C :- = ohms +/- % tolerance Air Cooler Fans N/A No off kW rating
Rotor Resistance @ 20 °C :- = ohms +/- % tolerance Cooling Medium N/A quantity of medium litres
Stator Resistance @ 20 °C :- = ohms +/- % tolerance Filters / no off / type N/A
Steady State Reactance:- X = % +/- % tolerance
Transient Reactance:- X' = % +/- % tolerance
Sub-Transient Reactance:- X'' = % +/- % tolerance
Zero Sequence reactance = % +/- % tolerance
X''/R Ratio:- =
Open Circuit Transient Time Constant:- = s OTHER DETAILS
Heating Time Constant:- = s
Cooling Time Constant:- = s Heater Rating:- N/A W ___V 1ph ac
Lubrication heater details N/A W ___V 1ph / ___V 3ph ac
Thermostat N/A Provided/Not Provided
Surge Absorber & capacitor N/A Required/Not Required
HAZARDOUS AREA CERTIFICATION Bearing Temp Detectors N/A No: Type:
Certifying Authority:- Winding Temp Detectors N/A No: Type:
Certificate No.:-

Protection type EExd EExp EExe Safe


Zone Group Temp
Purging System Data  Yes  No
Air Pressure required Bar
Air flow required Pre-start m3 Running m3
Aux power requirements

NOTES