You are on page 1of 1

Revision Page

Volvo Construction Equipment Group Service tip 1 1 (1 )


Reg No Release date Replaces
Volvo Articulated haulers, Customer Support
263-005 05-09-23
Issued by (dept, name, phone, sign.) Info class Appendix Insert

CSPA-6 Anders Nilsson


Subject Approved

Fan pump regulator applies for model: A25D/A30D/A35D/A40D

The information in this service tip can be changed without notice.

Background

When a machine get high temperature warning from either the water cooler side or intercooler side, or when a
machine does not get the right power the reason could be that the pwm2601, 2602 for the fan control speed has
dirt inside the spool and behind the small cross-hole, Regulator valve will then have malfunction.

PWM2602 fan control, radiator

PWM2601 fan control, intercooler

Action

Check the pressure / rpm for the fan pumps according to the Service Manual. If the fan pressure/rpm is low
remove the plug (1) and pull out the spool (2) clean spool and regulator with compressed air. Check the pressure
/ rpm and if necessary adjust the regulator

2. Spool. 0.8mm vertical


hole in the spool

1.plug

N:\Department\CST Parts & Service Product Support\Service Tips\2. Engine\263-005 Fan pwm.doc Printed: 05-
09-26 13:49