ANSI LUMINOUS TUBE FOOTAGE CHART

NORMAL MAXIMUM NUMBER OF FEET OF TUBING


OPERATED (Based on average grade of tubing)

TRANSFORMER RATINGS
PRIMARY RATING AT
SECONDARY
SHORT CIRCUIT
APPROXIMATE
(VOLT-AMPERES)
WATTS
SECONDARY SECONDARY
CONSUMPTION
VOLTAGE
CURRENT
AT 115 VOLTS
NORMAL
HIGH
(VOLTS)
(mA)
60-HERTZ
POWER POWER
FACTOR FACTOR
15,000

12,000

10,500
9,000

7,500

6,000

5,000

4,000

3,000

2,000

60
900
450
30
450
225
20
300
150
60
720
360
30
360
180
20
240
120
30
360
170
120
1080
540
60
540
270
30
270
135
20
190
95
120
900
450
60
450
225
30
225
115
20
160
80
120
720
360
60
360
180
30
180
90
20
140
70
120
600
300
60
300
150
30
160
80
20
110
55
60
240
120
30
140
65
20
90
45
60
190
95
30
100
50
20
75
38
30
75
38
20
50
25
RECOMMENDED GAS PRESSURE mm/Hg

463
234
151
374
187
125
140
561
281
140
99
463
234
117
86
374
187
94
73
312
156
83
55
125
73
50
94
52
42
42
29

Clear or Fluorescent Red


(Also recommended for Neon Fluorescent Gold)

TUBE SIZE, MILLIMETERS


25

22

20

18

15

14

13

12

11

10

102 85
102 85

78
78

72
72

79
79

67
67

61
61

55
55

73
77
67
67

62
65
57
57

55
55
48
48

48
46
40
40

59
51
51

47
41
41

39
34
34

32
28
28

46
40
40

39
34
34

32
28
28

26
23
23

38
33
33

32
28
28

26
23
23

22
19
19

27
27

23
23

19
19

16
16

17
17

14
14

12
12

10
10

7.5

60
60
50
45
45
40
39
38
33
33
28
28
24
24
22
22
19
19
17
19
17
17
14
13
13
11
10
10
8
7
6
9

54
54
47
42
42
38
36
34
30
30
26
26
23
23
21
20
18
18
16
18
16
16
13
12
12
10
9
9
8
6
5
10

50
50
44
39
39
33
34
33
29
29
24
25
22
22
20
19
17
17
15
17
15
15
13
11
11
10
9
9
7
6
5
10

45
45
40
35
35
30
31
30
26
26
22
23
20
20
18
18
16
16
14
14
12
12
11
10
10
9
8
8
6
6
5
11

39
39
34
30
30
26
26
25
22
22
18
18
16
16
14
15
13
13
10
11
10
10
8
8
8
7
7
7
5
5
4
12

33
33
27
25
25
21
22
22
19
19
15
15
13
13
12
12
11
11
9
10
9
9
7
7
7
6
6
6
4
4
3
13

27
27
24
21
21
18
18
17
15
15
13
13
11
11
10
10
9
9
7
8
7
7
6
6
6
5
5
5
4
4
3
15

Phone 1-800-661-7251
33 Cranfield Road Toronto, ON M4B 3H2 Canada

39

Fax 416-752-6717
www.allanson.com

ANSI LUMINOUS TUBE FOOTAGE CHART


NORMAL MAXIMUM NUMBER OF FEET OF TUBING OPERATED.
(Based on average grade of tubing)
Clear or Fluorescent Mercury Filled Tubes,
all colors
SECONDARY SECONDARY
Indoor applications
VOLTAGE
CURRENT
(40F Temp or above)
(VOLTS)
(mA)
TUBE SIZE, MILLIMETERS

Clear or Fluorescent Mercury Filled


Tubes, all colors
Outdoor applications
TUBE SIZE, MILLIMETERS.
For Temperature Below 40F (4.5C)

25 22 20 18 15 14 13 12 11 10 9 25 22 20 18 15 14 13 12 11 10 9
15,000

12,000

10,500
9,000

7,500

6,000

5,000

4,000

3,000

2,000

60
30
20
60
30
20
30
120
60
30
20
120
60
30
20
120
60
30
20
120
60
30
20
60
30
20
60
30
20
30
20

120 100 90 80 72
120 100 90 80 72
62
95 79 70 62 55
95 79 70 62 55
47
88 73 63 54 48
92 77 63 52 46
80 67 55 45 40
80 67 55 45 40
34
70 55 45 36 32
61 48 39 31 28
61 48 39 31 28
25
55 46 37 30 26
48 40 32 26 23
48 40 32 26 23
20
46 38 31 25 22
40 33 27 22 19
40 33 27 22 19
17
32 27 22 18 16
32 27 22 18 16
13
22 18 16 14 12
22 18 16 14 12
10
9
7
6
7 7.5 8
9

64
64
56
50
50
45
43
41
36
36
31
31
27
27
25
24
21
21
19
22
19
19
15
14
14
12
10
10
9
8
7
10

60
60
52
46
46
40
40
38
33
33
29
31
27
27
23
23
20
20
17
18
16
16
15
13
13
12
10
10
8
8
7
10

54
54
47
42
42
34
37
35
31
31
26
27
24
24
21
20
18
18
16
16
14
14
13
12
12
11
10
10
7
7
6
11

47
47
40
36
36
30
32
30
26
26
22
22
19
19
17
17
15
15
12
14
12
12
10
10
10
8
8
8
6
6
5
12

40
40
34
30
30
26
26
26
23
23
18
18
16
16
13
14
12
12
11
12
11
11
8
8
8
7
7
7
5
5
4
13

32
32
28
25
25
20
22
20
18
18
16
14
12
12
11
13
11
11
8
9
8
8
7
7
7
6
6
6
5
5
4
15

90 76 69 65 54
90 76 69 65 54
45
71 60 55 49 40
71 60 55 49 40
36
64 55 47 42 36
69 59 50 41 35
60 51 43 36 30
60 51 43 36 30
25
52 42 35 29 24
46 37 30 25 21
46 37 30 25 21
19
41 36 29 23 19
36 31 25 20 17
36 31 25 20 17
15
34 29 23 19 17
30 25 20 17 15
30 25 20 17 15
13
24 20 17 15 12
24 20 17 15 12
10
14 12 11 9 9
14 12 11 9 9
8
6
5
6
7 7.5 8 9

47
47
41
37
37
33
32
31
27
27
23
23
20
20
18
17
15
15
14
16
14
14
12
11
11
9
8
8
6
6
5
10

45
45
39
36
36
29
30
30
26
26
22
23
20
20
18
17
15
15
14
16
14
14
12
11
11
9
8
8
6
5
4
10

40
40
36
31
31
26
27
26
23
23
20
21
18
18
16
16
14
14
12
14
12
12
10
10
10
8
7
7
6
5
4
11

35
35
30
27
27
22
23
23
20
20
18
17
15
15
13
14
12
12
9
10
9
9
7
7
7
6
6
6
5
5
4
12

30
30
25
22
22
19
20
19
17
17
13
14
12
12
11
11
10
10
8
9
8
8
6
6
6
5
5
5
4
4
3
13

24
24
20
19
19
15
16
15
13
13
11
11
10
10
9
9
8
8
6
7
6
6
5
5
5
4
4
4
4
3
2
15

The above chart is only a guide. For proper loading use the flicker test for neon or a neon and mercury combination, the secondary
voltage test as outlined on pages 39 and 40, or our Selektor
- Each pair of electrodes equals 1 additional foot of length.
- Helium footages should be calculated at 50% of neon footages.
- For trouble-free operation, the tubing on each transformer should operate without flicker at 78% of rated primary voltage
(approximately 94-volts at a nominal line voltage of 120).

Phone 1-800-661-7251
33 Cranfield Road Toronto, ON M4B 3H2 Canada

40

Fax 416-752-6717
www.allanson.com