You are on page 1of 1

DATA SHEET - 1WDES-1000

PROJECT NAME COCONA RESORT


CONTACT PERSON PAK ANDI EKO PURNOMO
LOCATION GILI TRAWANGAN
LOMBOK- NTB

DESIGN & OPERATION CONDITION


TYPE PARAMETER UNIT
OPERATING HOUR 24 HOUR
SOURCE OF WATER SEA (SALT) WATER
3
PRODUCT WATER FLOW RATE 1.008 M /DAY
3
42 M /HOUR
SYSTEM CONFIGURATION TEN STAGE - TWO LANES
o
DESIGN TEMPERATURE 5 - 45 C
o
OPERATING TEMPERATURE 32 C
SYSTEM SPECIFICATIONS
POWER SUPPLY 380-415/50 Vac/Hz
RATED POWER 154 KVA
MAX FEED TDS 30.000 mg/l
PERMEATE TDS < 500 mg/l
SALT REJECTION RATE 99,5 %
RECOVERY RATE 35-45 %
MIN SPACE INSTALATION 9(L) X 6(W) X 3,5(H) m
WEIGHT 20.000 Kg
MEMBRANE SPECIFICATIONS
PROPOSED MEMBRANE SW30XLE-400i DOW
NUMBER OF MEMBRANE 60 PIECES
2
MEMBRANE AREA 41 M /PIECES
3
FEED FLOW RATE 2.500 M /DAY
SALT REJECTION 99,8 %
BORON REJECTION 91,5 %
o
MAXIMUM OPERATING TEMPERATURE 45 C
MAXIMUM OPERATING PRESSURE 65 BAR
MAXIMUM ELEMENT PRESSURE DROP 1 BAR
MAXIMUM FEED SDI 5 SDI
FREE CHLORINE TOLERANCE <0.1 mg/l
ENERGY CONSUMPTION
OVERALL ELECTRICAL OPERATING 123,5 Kw
RAW WATER PUMP (2 UNIT) 15 Kw/unit
FEED WATER PUMP 18,5 Kw/unit
HIGH PRESSURE PUMP 55 Kw/unit
CHEMICAL DOSING PUMP (4 UNIT) 0,25 Kw/unit
CLEANING PUMP 18,5 Kw/unit
OTHER 0,5 Kw/unit
MAX CHEMICAL CONSUMPTION ( PER CLEANING )
BACTERICIDES 15 Kg
FLOCCULANT 20 mg/l
INHIBITOR 20 mg/l
CITRIC ACID (FOOD GRADE) 20 Kg
ALKALINE 4 Kg