You are on page 1of 2

AMMONIA-UREA II PROJECT PROJ NO.

201485
MECHANICAL DATA SHEET REV 2
ULTRA FILTRATION 201485-Z20212-01

1 Tag No. Item No. S20203 A-D 4

GENERAL 2 P&ID No. PHB-POT-WT25-010-011

3 Service Ultra Filtration

4 Feed Water ACF Filtrate Water

5 Density 993 kg/m3

6 Viscosity 0.628 cP

7 Input capacity/skid Max. Norm. Min. 95.9 93 84 m3/h

8 Filtration capacity/skid Max. Norm. Min. 95.9 93 84 m3/h (Note 1)

9 Filtration capacity/skid Max. Norm. Min. 92.64 89.84 81.14 m3/h (Note 2)

10 Operating Pressure Max. Norm. Min. 2.92 2.14 1.76 kg/cm g

11 Operating Temperature Max. Norm. Min. 40 AMB 20 C

12 Operating Flux 72.2 L/m3/h

13 Operating System Recovery 95.4 %


PROCESS
14 Filtration Mode Dead End/Cross flow
CONDITION
15 Expected Water Turbidity Input Permeate 5.00 0.2 NTU

16 Expected SDI Permeate 3

17 Expected ORP Level for Permeate < 750 mV

18 Pre-set timer/sequence (minutes) 45 Filtration 0.33 Air scouring 0.33 Drain 1.0 Top-Bottom Backwash 1 Flushing

19 Backwash water UF Filtrated Water

20 CEB Backwash Ater 20 cycle of the sequences

21 Backwash capacity/skid Max. Norm. Min. 150 131 131 m3/h


3
22 Air Scouring Capacity Max. Norm. Min. 216 204 90 Nm /h for 20 seconds

23 Air Scouring Pressure Max. Norm. Min. 2.5 2 1 kg/m3

24 CIP Capacity Max. Norm. Min. 25.5 20 17 m3/h

25 Model Dow UF SFP-2880


26 Fiber material Hydrophilic - PVDF

27 Nominal pore size 0.03 mm

28 Filtration flux 40 - 120 L/m2.h


29 Active membrane area 77m2 (829 ft2)
30 Number of skid 4
UF MECHANICAL
31 Number of module/skid 18
DATA
32 Number of Total UF 68
33 Operating Temperature Max. Norm Min. 40 AMB 20 C

34 Maximum Feed Pressure 6.25 kg/cm at 20 C

35 Maximum operating TMP 2.1

36 Cleaning water pH 2 - 11

37 Max CEB NaOCl 2000 mg/L

38 Design Pressure Design Temperature 5 kg/cm g 20 C

39 Type Low pressure vessel


40 Material UPVC
41 Housing Diameter Diameter 225 mm
MEMBRANE
42 Height Housing 2320 mm
HOUSING
43 Water volume/module 39 L (10 gal)
44 Design Code As per Dow Standard

45 Inspection Methode Visual inspection

46 Hydrotest Test certificate shall be provided

47 Feed Water Inlet Port, N1 Rat & Fac. 2" #150 Grooved
48 Filtrate Port, N2 Rat & Fac. 2" #150 Grooved
CONNECTION
49 Reject/Crossflow Port, N3 Rat & Fac. 2" #150 Grooved
50 Air inlet, N4 Rat & Fac. 3/8" #3000 NPT

MATERIAL OF 51 Housing Material UPVC


CONSTRUCTION 52 Bolt and Nut SS 304

Note 1: Based on Dead End Filtration Mode when NTU < 30

Note 2: Based on Cross Flow Filtration Mode, 3.4% of input water is cross flowed due to backwashc requirement of MMF-ACF for DW
DATASHEET