You are on page 1of 32

WBOX LIQUID

USER MANUAL
LIQUID - User Manual

Weighing and Batching System WBOX2 Series


Model LIQUID
Weighing and Batching System with graphic display to measure data from load cells with
extensometer.
The information on the display can be weight or volume, through the kg/l user settable conversion
factor.

Applications
• Liquid products tanks weighing
• Liquid products refrigerators weighing
• Mixers weighing
• Stocking plants weighing
• Every system being weighed with load cells

Available Accessories
• External siren
• Thermal printer
• GSM - GPRS Modem
• Remote Display
• Communication and storage options:
* Ethernet
* RS485/422
* USB
• LIN bus extension boards: 2 DIGITAL INPUTS + 4 DIGITAL OUTPUTS
• LIN bus extension boards: 16 DIGITAL INPUTS + 1 DIGITAL OUTPUT
• LIN bus extension boards: 1 or 2 ANALOG OUTPUTS 4÷20 mA or 0÷5 V, 0÷10 V
• Load cells junction boxes
• Cables to connect the system to the load cells junction boxes
• Cables to connect the accessories

1
DigiDevice

GENERAL WARNINGS
Read carefully this manual before using the weight indicator

• Be sure that the electrical power supply is as per system requirements

• Do not push on the display as this may cause some afterimages

• Do not rub or strike the display with anything hard as this may scratch, mar, or damage it perma-
nently

• Do not use scratching tools to push buttons

• Do not use chemical dissolvent to clean the indicator

• Do not apply any water jet, high or low pressure, on the system or on its parts

• Use only accessories approved by the manufacturer

• Only qualified personnel can do maintenance on the system

• Do not try to open or misuse the system

• Use the system only for the purpose and following the specifications in this user manual

• Do not throw away the carton and packing materials. They make an ideal container in which to trans-
port the unit. When shipping the unit to another location, repack it in its original material

• Do not dispose of this product with general household waste

• Disposal of this product must be carried out in accordance to the regulations of your local authority

2
LIQUID - User Manual

Summary
CONVENTIONS...................................................................................................... 6
SYSTEM DESCRIPTION........................................................................................ 7
MAIN FUNCTIONS.................................................................................................. 8
Preliminary Operations....................................................................................... 8
Working Menu.................................................................................................... 9
Selection Menu................................................................................................. 10
Strings inserting Menu...................................................................................... 11
Special Menus.................................................................................................. 13
Menus Functions List....................................................................................... 14
FUNCTIONS DESCRIPTION................................................................................ 16
Total Weight [1]................................................................................................. 16
Liters / Kilograms display............................................................................ 16
Zero-setting of Total Weight........................................................................ 16
Manual Weight Storage............................................................................... 16
Shortcut to the Last Stored Weight Memory............................................... 17
How to print the displayed weight value...................................................... 17
Partial Weight [2].............................................................................................. 17
Partial Weight zeroing................................................................................. 17
Shortcut to the Total Weight menu.............................................................. 17
How to print the displayed weight............................................................... 17
Stored Weight Memory [3]................................................................................ 18
LAST STORED WEIGHT [3.1].................................................................... 18
View [3.1.1]............................................................................................ 18
Clear [3.1.2]............................................................................................ 18
Erase last weight [3.1.3]......................................................................... 18
MONTHLY REPORT [3.2]........................................................................... 18
ACQUISITION MODE [3.3]......................................................................... 18
Manual (Key +) [3.3.1]............................................................................ 18
Auto (every Unload) [3.3.2].................................................................... 19
PRINTOUTS [3.4]........................................................................................ 19
Last Stored Weights [3.4.1].................................................................... 19
Monthly Report [3.4.2]............................................................................ 19
USB MEMORY [3.5].................................................................................... 19
SYSTEM SETTING............................................................................................... 20
System Information [4]..................................................................................... 20

3
DigiDevice

Settings [5]....................................................................................................... 20
USER PREFERENCE [5.1]......................................................................... 20
Language [5.1.1].................................................................................... 20
Display [5.1.2]........................................................................................ 20
Display Contrast [5.1.2.1].................................................................. 20
Display Brightness [5.1.2.2].............................................................. 20
Light Option [5.1.2.3]......................................................................... 20
Keypad Tones [5.1.3]............................................................................. 21
Graphic Settings [5.1.4].......................................................................... 21
Animations [5.1.4.1].......................................................................... 21
Menu Titles [5.1.4.2].......................................................................... 21
Operation Messages [5.1.4.3]........................................................... 21
Help on Selection [5.1.4.4]................................................................ 21
Help on Icons Function [5.1.4.5]....................................................... 21
Command Description [5.1.4.6]........................................................ 21
Password [5.1.5].................................................................................... 21
Password Activate [5.1.5.1]............................................................... 21
Modify Password [5.1.5.2]................................................................. 21
WEIGHT OPTIONS [5.2]............................................................................. 22
Weight Resolution [5.2.1]....................................................................... 22
Weight Velocity [5.2.2]............................................................................ 22
Undo Tare [5.2.3].................................................................................... 22
Master Weight Calibration [5.2.4]........................................................... 22
Conv. Coefficient (kg/l) [4.2.5]................................................................ 23
System Name [5.2.6].............................................................................. 23
Min. Sample Threshold [5.2.7]............................................................... 23
Unload Threshold [5.2.8]........................................................................ 23
Weighing Time [5.2.9]............................................................................ 23
CLOCK AND CALENDAR [5.3]................................................................... 23
Date Time setting [5.3.1]........................................................................ 23
Auto Daylight Saving Changes [5.3.2]................................................... 24
ACCESSORIES [5.4].................................................................................. 24
Printer [5.4.1].......................................................................................... 24
Modem [5.4.2]........................................................................................ 24
Remote Display [5.4.3]........................................................................... 24
USB Memory [5.4.4]............................................................................... 24
SETTINGS RECOVERY [5.5]..................................................................... 24
RESERVED AREA [5.6].............................................................................. 24

4
LIQUID - User Manual

TROUBLESHOOTING.......................................................................................... 25
Weight Reading Problems................................................................................ 25
Out of Scale System or Weight Error.......................................................... 25
Unstable Weight Value................................................................................ 25
Wrong Weight Value.................................................................................... 25
The measure is correct in Kilograms, but wrong in Liters........................... 25
Other Problems................................................................................................ 25
Difficult Display reading .............................................................................. 25
TECHNICAL DATA................................................................................................ 26
WARRANTY.......................................................................................................... 27
DECLARATION OF CONFORMITY...................................................................... 28

5
DigiDevice

CONVENTIONS

The information notes contain important information, highlighted outside the text which they
refer

When the weight indicator is connected to more systems (for models which support multiple
systems), a note describes how to do with the sequences.

The caution messages contain important information to avoid behavior of the equipment
different from the desired.

The words in colored bold refers to screenshots, descriptions and topics in the chapter MAIN
FUNCTIONS.

6
LIQUID - User Manual

SYSTEM DESCRIPTION
FRONT VIEW
1. DISPLAY
2. KEYS

CONNECTORS SIDE VIEW, ABS CASE VERSION


A. POWER SUPPLY
CONNECTOR
B. ACCESSORIES
CONNECTOR
C. USB PORT (DEPENDS ON
E A MODEL)
D. SENSORS CONNECTOR 2
(DEPENDS ON MODEL)
D C B E. SENSORS CONNECTOR 1

CONNECTORS SIDE VIEW, PANEL VERSION


A. POWER SUPPLY
CONNECTOR
C B. ACCESSORIES
CONNECTOR
J
C. RS-485 CONNECTOR
(DEPENDS ON MODEL)
S1/S2 E
D. SENSORS CONNECTOR 2
O D (DEPENDS ON MODEL)
E. SENSORS CONNECTOR 1
J. CAN CONNECTOR
(DEPENDS ON MODEL)
L. DIGIDEVICE BUS
CONNECTOR
N. ETHERNET CONNECTOR
A L B N (DEPENDS ON MODEL)
O. I/O CONNECTOR
S1 / S2 RS-232 CONNECTOR
(DEPENDS ON MODEL)

7
DigiDevice

MAIN FUNCTIONS

Preliminary Operations

Before starting
Check that the power supply cable (connector A) and the load cells cable (connector E) are connected
to the Indicator.

Switching on and off

To switch on the system press shortly the On / Off Key . The Indicator display will light on, while
the initializing messages and the presentation are displayed.

To switch off the system press the On / Off Key for about 3 seconds

Selection keys

Use the keys and to select an item in a list or modify digits or values.

Alphanumeric keys

Use the alphanumeric keys to introduce numbers and other characters in different screens. Press
quickly more times the key to select the different characters associated to the same key.

Operating Keys

Ok Key To confirm and/or go forward in a menu

Clear Key To cancel and/or go back in a menu

Menu Key To open and close the Selection Menus, if not else specified

8
LIQUID - User Manual

Working Menu

In a Working Menu a weight value and/or some functions related to weight are displayed.
The display is divided in working areas containing user information

2 3

1. WEIGHT AREA

In this area the weight value is displayed during weighing operation.


2. ICONS AREA

Select an icon in this area using the selection keys. An icon is selected when is inside a blinking

rectangle. To execute the function connected with the selected icon, press .

When the icons are more than those which can be displayed in the icons area, a scroll bar is displayed
under the icons. The scroll bar will show the selected icon position among all the available icons.

3. DIALOG AREA

In this area useful information about the system status or the actual menu are displayed.
This area is also used when a confirmation by the user is needed to do an operation: the question and
the list of all the user selectable answers is displayed

9
DigiDevice

Selection Menu

In a Selection Menu a list of items describing settings, options or menu access are displayed.
The Selected Item is the only one displayed in white on black background
Use the selection keys to select an item.

Press to confirm the selection: the system will perform the selected function.

Press to go back to the previous menu.

Press to switch between the selection menus and the Total Weight [1] menu.

1 6 5

2 3

1. MENU ICON
Selection Menu icon
2. SELECTED ITEM ICON
For some selection menus, this icon shows the menu that can be accessed by confirming the selected
item
3. HELP AREA
In this area the properties of the selected item are displayed. The function shall be available and
selected
4. SCROLL BAR
If the selectable items are so many that they cannot be all displayed in the same screen, a scroll bar will
display the selected item position among all the available items
5. SELECTION MENU TITLE
Selection Menu title
6. SELECTED ITEM

10
LIQUID - User Manual

Strings inserting Menu

STRING means a characters list used to create a WORD (for instance, a NAME or a
NUMBER,…)

1 4

1. SELECTED CHARACTER
2. INSERTED STRING
3. MENU NAME
4. CHARACTERS LIST

Use the selection keys to select a character in the CHARACTERS LIST


The selected character is the only one displayed in white on black background in the CHARACTERS
LIST.

Use the key to add the selected character to the INSERTED


STRING.
If the cursor is on the last character that can be insert, when

pressing the string is confirmed and the system goes to the


previous menu.

The key cancels the selected character in the string and goes
to the previous character. If the cursor is on the first character,

when pressing the string will not be stored and the system
goes to the previous menu.

11
DigiDevice

If the key is kept pressed while also pressing the key,


the cursor goes back without deleting the previous characters.

If the key is kept pressed while also pressing the key,


the cursor goes forward and clears next characters.

Keeping pressed the key for about 3 seconds, the inserted string will be confirmed and the system
goes back to the previous menu.

Keeping pressed the key for about 3 seconds, the inserted string will be cleared

12
LIQUID - User Manual

Special Menus

Special Menus are all those with different style compared with those described before.
Special Menus are Data Inserting Menus, Setting Menus or Wizard Menus to perform special
calibration operations (Example: Master Weight Calibration Menu).

DATA INSERTING MENU

Change the selected value using the selection keys or insert the
value through the alphanumeric keys.

The key confirms the value and moves the cursor forward.

When the last value is inserted, pressing , the system goes


to the previous menu.

The key moves the cursor backward. When the cursor is on

the first position, pressing , the system goes to the previous


menu without saving

SETTING MENU

Use the selection keys to change the selected item or value.

The key confirms and the system goes to the previous


menu.

Pressing , the system goes to the previous menu without


saving

WIZARD MENU

These menus are based on step by step instructions for the


operator.

Use key to confirm and key to cancel

13
DigiDevice

Menus Functions List

1. Total Weight
2. Partial Weight
3. Weights Memory
3.1. Last Stored Weights
3.1.1. View
3.1.2. Erase
3.1.3. Erase Last Weight
3.2. Monthly Report
3.3. Acquisition Mode
3.3.1. Manual (Key +)
3.3.2. Auto (Every Unload)
3.4. Printouts
3.4.1. Last Stored Weights
3.4.2. Monthly Report
3.5. USB Memory
4. System Information
5. Settings
5.1. User Preference
5.1.1. Language
5.1.2. Display
5.1.2.1. Display Contrast
5.1.2.2. Display Brightness
5.1.2.3. Light Options
5.1.3. Keypad Tones
5.1.4. Graphic Settings
5.1.4.1. Animations
5.1.4.2. Menu Titles
5.1.4.3. Operation Messages
5.1.4.4. Help on Selection
5.1.4.5. Help on Icons Function
5.1.4.6. Command Description
5.1.5. Password
5.1.5.1. Password Activate
5.1.5.2. Modify Password
5.2. Weight Options
5.2.1. Weight Resolution
5.2.2. Weight Velocity
5.2.3. Undo Tare
5.2.4. Master Weight Calibr.
5.2.5. Conv. Coefficient (kg/l)
5.2.6. System Name

14
LIQUID - User Manual

5.2.7. Min. Sample Threshold


5.2.8. Unload Threshold
5.2.9. Weighing Time
5.3. Clock and Calendar
5.3.1. Date Time setting
5.3.2. Auto Daylight S.T.
5.4. Accessories
5.4.1. Printer
5.4.2. Modem
5.4.3. Remote Display
5.4.4. USB Memory
5.5. Settings Recovery
5.6. Reserved Area

15
DigiDevice

FUNCTIONS DESCRIPTION

Total Weight [1]

Liters / Kilograms display

In the Total Weight menu, the measured value can be displayed as kilograms or liters.
The selected display mode (kg or l) is written in the DIALOG AREA. To switch between a display mode

and the other, select the icon , then confirm by pressing the key.

Use the Conv. Coefficient (kg/l) [5.2.5] menu to set the relation between kilograms an liters.

WARNING: The acquired data is always WEIGHT, even when the display is in liters.
The liters display is due to an operation linked to the settled conversion coefficient. The volume
of a liquid is affected by a variation due to temperature, so the conversion accuracy will strictly
depend on the conversion coefficient precision, based on the tank operating temperature.

Zero-setting of Total Weight

Following operation shall be done to zero the Total Weight, for instance when the System is empty:

keep the key pressed for about 3 seconds or select, through the selection keys, the icon and

confirm selection by the key.

In the DIALOG AREA the operation confirm request will be displayed: select “Yes” through the selection

keys and confirm with the key. A message will inform about the zeroing.

The last zeroing of the Total Weight can be aborted, for instance if zeroing was accidentally
done, through the Undo Tare [5.2.3]

Manual Weight Storage

If the weight acquisition mode is settled to “Manual (key +)” in the Acquisition mode [3.3] menu, the

icon will appear in the icons area. Select the icon with the selection keys and confirm with to
save the weight value together with its date and time.

16
LIQUID - User Manual

Shortcut to the Last Stored Weight Memory

If the weight acquisition mode is settled to “Auto (every unload)” in the Acquisition mode [3.3] menu,

the Last Stored Weight list can be accessed selecting the icon and confirming by .

How to print the displayed weight value

If a printer is connected to the system and activated, the displayed weight value can be printed by

selecting the icon and confirming with .

Access the Activate Printer [5.4.1] menu to activate the printer.

Partial Weight [2]

The actual weight is zeroed and its variation, positive or negative, are displayed.
The zeroing can be repeated even from the partial weight screen.

Partial Weight zeroing

Select the icon, than confirm by to zero the Partial Weight.


A message will confirm the new zeroing operation.

Shortcut to the Total Weight menu

To quickly access the Total Weight [1] menu, select the icon and confirm by the key.

How to print the displayed weight

If a printer is connected to the system and the function is activated, the displayed weight can be printed

by selecting the icon and confirming by the key.

Access the Activate Printer [5.4.1] menu to activate the printer.

17
DigiDevice

Stored Weight Memory [3]

LAST STORED WEIGHT [3.1]

View [3.1.1]
In this menu a list of the last stored weight in both manual and automatic s displayed.
The data pages can be scrolled through the selection keys. The page number is displayed on the screen.

The data display can be in liters or kilograms, based on the selected measure unit. Use the
icon in the Total Weight[1] menu to modify the measure unit.

Clear [3.1.2]
The stored weight data can be cleared.
The operation shall be confirmed.

Erase last weight [3.1.3]


The last acquired weight can be cleared.
The operation shall be confirmed.

MONTHLY REPORT [3.2]

In this menu the total monthly weight value and the monthly number of weighing operations is displayed
as a diagram. Months can be scrolled through the selection keys.
The cursor blinks on the selected data.
On the upper area of the display the Year and Month are written.
On the lower part of the display, the total weight amount of the selected month and the number of
weighing operations in the selected month are displayed.

The data display can be in liters or kilograms, based on the selected measure unit. Use the
icon in the Total Weight[1] menu to modify the measure unit.

ACQUISITION MODE [3.3]

Use this menu to select manual or automatic storage mode.

Manual (Key +) [3.3.1]

Select Manual (key +) [3.3.1] to allow storage when the icon in the Total Weight [1] menu is

18
LIQUID - User Manual

selected and the key is pressed.

Auto (every Unload) [3.3.2]

By selecting the Auto (every unload) [3.3.2] option, the weight storage will be done automatically by
the system. The acquired weight will be the last stable weight before the tank unloading operation.
The weight value is stable when its variation suits the stability criteria settled during installation. That
weight shall be stable for a time as in parameter Weighing Time [5.2.9].
Besides that, the weight value will be stored if its value will be more or equal to the parameter Min.
Sample Threshold [5.2.7].
The storage operation is performed during the tank upload, when the weight value decreases up to the
value settled for parameter Unload Threshold [5.2.8].

PRINTOUTS [3.4]

Last Stored Weights [3.4.1]


If a printer is connected, the last stored weight list is printed.

Monthly Report [3.4.2]


If a printer is connected, the monthly total weight values is printed.

USB MEMORY [3.5]

Select the menu entry (available only on versions with integrated USB connector) and press .A

message requires the operator to press again the key to store the data on the USB memory. Next
message informs about storage result, in case of executed operation, empty weight indicator memory
or USB memory not inserted.

19
DigiDevice

SYSTEM SETTING

System Information [4]

Selecting the System Information item in the Main Menu, the menu regarding the system and accessories
status and settings will be displayed.

Settings [5]

Select the Settings item in the Main Menu to access the weight indicator settings screen.
Here the weight indicator can be configured and the parameters can be properly calibrated to guarantee
the best system performance.

USER PREFERENCE [5.1]

Language [5.1.1]
This screen allows the operator to choose the menus language from a list.

Select the option with the selection keys and confirm by .

Display [5.1.2]

Display Contrast [5.1.2.1]


This screen allows the operator to adjust the display contrast.

Select the value with the selection keys and confirm by .

Display Brightness [5.1.2.2]


This screen allows the operator to adjust the display brightness.

Select the value with the selection keys and confirm by .

Light Option [5.1.2.3]


This screen allows the operator to select one of the three light options of the display.
• Light always off;
• Light always on;
• Energy Saving: when the indicator is not used, after a few seconds, the light turns off. Touching a
key, the light will switch on.

Select the option with the selection keys and confirm by .

20
LIQUID - User Manual

Keypad Tones [5.1.3]


If this function is activated, a short tone will be generated every time a key is pressed

Select the option with the selection keys and confirm by .

Graphic Settings [5.1.4]

Animations [5.1.4.1]
If this function is activated, the graphic items in the screens will be animated (moving icons, pop-up
descriptions and menu presentations).

Menu Titles [5.1.4.2]


If this function is activated, the accessing menu title will be displayed for three seconds.

Operation Messages [5.1.4.3]


If this function is activated, the indicator will show a short message to confirm the result of the selected
operation.

Help on Selection [5.1.4.4]


If this function is activated, in the Selection Menus, a brief description of the selected item will be
displayed in the HELP AREA.

Help on Icons Function [5.1.4.5]


If this function is activated, in the Working Menus, a brief description of the selected icon in the ICONS
AREA will be displayed in the HELP AREA.

Command Description [5.1.4.6]


During the options selection, in a Selection Menu or in a Working Menu, if the user does not press the
selection keys for more than 3 seconds, a brief description of the keys function in that menu is displayed
in the HELP ZONE.

Password [5.1.5]
The system has a PASSWORD to avoid the access to functions that might cause wrong system working,
if not properly used.

Password Activate [5.1.5.1]


Enter this menu to activate / deactivate the PASSWORD.

Modify Password [5.1.5.2]


Enter this menu to modify the PASSWORD.

21
DigiDevice

If the PASSWORD is active, insert it to go into the Password Activate [5.1.5.1] and Modify
Password [5.1.5.2] menus.

If the user forgets the PASSWORD, please contact the nearest DigiDevice assistance for the
system unlocking procedure.

WEIGHT OPTIONS [5.2]

If the PASSWORD is active, may be necessary to insert it to access this menu

Weight Resolution [5.2.1]


This menu is to select the indicator resolution, that is the minimum variation that the system can
display.

Select the value with the selection keys and confirm by .

Weight Velocity [5.2.2]

This menu is to select the weight value refresh speed. Set a low value to select a longer refresh time.
The digital filtering, determining the weight value refresh speed, allows a reading stabilization, in case
of vibrations on the system or on its components.

Select the value with the selection keys and confirm by .

When the Dynamic option is selected, the system applies a new filtering algorithm to the weight
value. This allows high precision and stability of the weight value.

Undo Tare [5.2.3]


Entering this menu, a Wizard starts, to cancel the last Total Weight [1] zeroing operation.
The display shows how the Total Weight will be after Undo Tare operation

Select the option with the selection keys and confirm by

Master Weight Calibration [5.2.4]


This Wizard is to do the system calibration using a Master Weight.
Follow the wizard steps to do the operation.
This operation may be needed when the weight displayed by the indicator is not accurate enough.

The more the Master Weight is near to the scale capacity, the higher is the calibration accuracy.
Using too light Master Weights during calibration may cause not enough accurate weight
reading.

22
LIQUID - User Manual

CAUTION: This operation cannot be canceled and shall be done only if really needed

Conv. Coefficient (kg/l) [4.2.5]


This parameter value defines the relation between kilograms and liters.

Select the desired value with the selection keys and then press .

Example A: 1 liter of the product = 1.029 kg


The conversion coefficient is: 1,029

Example B: 1 kg of product = 0,971 liters


The conversion coefficient is: 1 / 0,971 = 1, 029

System Name [5.2.6]


Enter this menu to name the systems.

The system name will be displayed in the Total Weight [1] menu and in every dialog menu where the
system shall be selected

Follow the instructions in the String Inserting Menu to insert a system name. The String Inserting
Menu is in the introduction section of this manual, in the SPECIAL FUNCTIONS chapter.

Min. Sample Threshold [5.2.7]


This parameter is to set the minimum weight to acquire. During automatic working, the system does not
acquire weight values below the value settled in this parameter.

Unload Threshold [5.2.8]


This parameter is used during automatic working. Data are stored in memory when the system detects
a weight value below the value of this parameter.

Weighing Time [5.2.9]


The weight value shall be stable for a time higher than the value of this parameter to allow the system
to acquire valid data.

CLOCK AND CALENDAR [5.3]

Date Time setting [5.3.1]


This is a Data Inserting Menu which allows the user to set the indicator’s clock and calendar.

The key and the key allow to go forward and backward into the time and date menu and the
numeric keys are used to change the selected value.

23
DigiDevice

Auto Daylight Saving Changes [5.3.2]


This option allows to automatically adjusting the clock for daylight saving changes.

Select the option with the selection keys and confirm by

The clock changes are based on the European normative LEGAL TIME.

ACCESSORIES [5.4]

Printer [5.4.1]
This option is to access the thermal printer features, if connected to the system, and activate its working
mode.

Modem [5.4.2]
This option is to access the modem features, if connected to the system, and activate its working
mode.

Remote Display [5.4.3]


This option activates the weight repeater indicators, if connected to the system. The selection list is the
communication protocols list that the indicator supports.

Select the option with the rotor and confirm by

Please refer to the weight repeater manual to choose the right communication protocol.

USB Memory [5.4.4]

This option activates an external USB memory connected to the system (optional), to store the data
involved in the system operations.

SETTINGS RECOVERY [5.5]

Entering this menu, a Wizard starts, to recover the manufacturer’s settled standard parameters.

If a PASSWORD is active, insert it to access this menu.

CAUTION: This operation cannot be canceled and shall be done only if really needed

RESERVED AREA [5.6]

The settings in this menu are reserved to system installation engineers. The INSTALLER PASSWORD
is needed to access this area.

24
LIQUID - User Manual

TROUBLESHOOTING

Weight Reading Problems

Out of Scale System or Weight Error

• Some “ ! ” symbols are displayed in the WEIGHT AREA and the alarm type is specified in the DIA-
LOG AREA.

a. Disconnect the weight sensor cable (CONNECTOR E) and check whether there is humidity.
If the problem is due to humidity, let the connector dry, then connect it and check the proper
operating.
b. If the error status disappears when disconnecting the weight sensor cable (CONNECTOR E),
the problem may be due to a load cell or to its cable. Check cable and sensor.
c. If the error status remains, even when disconnecting the weight sensor cable (CONNECTOR
E), contact the assistance.

Unstable Weight Value

• Disconnect the weight sensor cable (CONNECTOR E) and check whether there is humidity. If the
problem is due to humidity, let the connector dry, then connect it and check the proper operating.

Wrong Weight Value

• The system calibration through the Master Weight Calibration [5.2.4] might be necessary.

The measure is correct in Kilograms, but wrong in Liters

• Check the value of the kilograms to liters conversion coefficient. Refer to the menu Conv. Coef-
ficient (kg/l )[5.2.5].

Other Problems

Difficult Display reading

• If the display appearance is too light or too dark, access the Display Contrast [5.1.2.1] menu to
adjust the contrast.

25
DigiDevice

TECHNICAL DATA *
Voltage Power Supply 10 ÷ 30 V DC
Maximum Consumption 12 W
Load Cells Excitation Voltage 5 V DC
Divisions 60 000
Resolution x1 x2 x5 x10
Number of Connectable Load Cells Verify with the installer
Weight Display Refresh Rate Software selectable
Weight A/D Converter Delta Sigma 24 bit
Interface Commands Operating + alphanumeric keys
Display LCD matrix 240x128 - 114 x 64 mm
Backlighting LED
Luminosity ~ 46 cd/m2
Microprocessor 16 bit 56Mhz
Memory Flash + Static RAM + E2PROM
Communication Port RS 232
Inputs -
Outputs -
Acoustic Signaling Internal Buzzer
Protection Grade IP 65
Working Temperature 0 ÷ 50 °C0
Stock Temperature -20 ÷ 80 °C
Humidity 90 %
Vibration Test (x-y-z for 1hr) 20 ÷ 50Hz -> 1.0G / 51 ÷ 300Hz -> 0.5G
Housing ABS
Color Grey
Mounting Fixture Stainless Steel Bracket
Dimensions 190 x 182 x 100 mm (L x H x P)
Weight ~ 950 g
Conformity CE Normative Conformity

* Product features may change without notice

26
LIQUID - User Manual

WARRANTY
This warranty shall apply in Europe. DigiDevice control of DigiDevice, unless the defect
Srl warrants that this Product is at the time of was caused directly by defects in materi-
its original purchase free of defects in materials, als, design or workmanship.
design and workmanship subject to the following
terms and conditions: b. The authorized service company was
not notified by the Customer of the de-
fect within thirty (30) days after the ap-
1. This warranty is given to the end purchaser of pearance of the defect within the war-
the Product. It shall neither exclude nor limit: ranty period.
a. Any mandatory statutory rights of the c. The Product serial number has been
Customer, or removed, erased, defaced altered or is
illegible.
b. Any of the Customer’s rights against the
seller/dealer of the Product. d. The defect was caused by the fact that
the Product was used with or connected
2. The warranty period is twelve (12) months to an accessory not approved by DigiDe-
from the date on which the first Customer pur- vice or used in other than its intended
chased the Product. In case of a subsequent use.
Purchase or other change of owner/user, such
warranty period shall continue for the remain- e. The defect was caused by short-circuit
ing part of the twelve (12) of the period and or bad power supply.
otherwise remain unaffected.
7. To claim this warranty the Customer shall
3. During the warranty period DigiDevice or its present a legible and non-modified original
authorized service company will repair or purchase receipt, with the name of the seller/
replace, at DigiDevice sole discretion, a de- dealer of the Product.
fective Product. DigiDevice will return the
repaired Product or another Product to the 8. This warranty is the Customer’s sole and
Customer in good working condition. All parts exclusive remedy against DigiDevice and
or other equipments which replacement have DigiDevice’s sole and exclusive liability
been provided shall become the property of against the Customer for defects or malfunc-
DigiDevice. tions of the Product. This warranty replaces all
other warranties and liabilities, whether oral,
4. A repaired o replaced Product will not be given written (non mandatory) statutory, contractual
a prolonged or renewed warranty period. in tort or otherwise. DigiDevice is no even li-
able for any incidental, consequential or indi-
5. This warranty shall not apply the deteriora- rect damage, costs or expenses.
tions due to normal wear and tear.
6. This warranty shall further not apply if:
a. The defect was caused by the fact that
the Product has been subjected to: use
in contradiction with the user’s manual,
rough handling, or extreme thermal or
environment conditions, unauthorized
modifications or connections, unauthor-
ized opening or repair, repair by use of
unauthorized spare parts, misuse, im-
proper installation, accident, forces of
nature, influence from chemical prod-
ucts or other acts beyond all reasonable

27
DigiDevice

DECLARATION OF CONFORMITY
Dichiarazione di Conformità
Noi / We:

DigiDevice Srl
via dell’Artigianato, 9
25012 – Calvisano (BS)
ITALY

fabbricante dei prodotti di seguito indicati


manufacturer of the below indicated products

dichiariamo sotto nostra unica responsabilità che i prodotti


declare under our sole responsibility that the products

Indicatore Serie WBOX


WBOX Series Indicator

ai quali si riferisce la presente dichiarazione, sono conformi alla/e seguente/i direttiva/e o


documento/i normativo/i:
to which this declaration relates, are in conformity with the followings directive(s) or other normative
document(s):

Conformità CE / CE Conformity:

Direttiva CEE 2014/30/EU sulla Compatibilità Elettromagnetica


2014/30/EU Directive relating to Electromagnetic Compatibility

Direttiva 2011/65/UE sulla Restrizione dell’uso di Determinate Sostanze Pericolose nelle


Apparecchiature Elettriche ed Elettroniche
Directive 2011/65/EU on the Restriction of the Use of Certain Hazardous Substances in Electrical
and Electronic Equipment

Data / Date: 12/11/2018

Il Responsabile Tecnico
The Technical Manager
Nicola Roncali

28
Authorized seller

+39 030 99 88 818



Via dell’Artigianato, 9  +39 030 20 53 423
25012 - Calvisano (BS)
Italy  info@digidevice.com

 www.digidevice.com