FLOOR STANDING TROPICAL 60HZ R-410A COOLING ONLY

YLFE 60 BZH3CMSR5
FLOOR STANDING TROPICAL 60HZ R-410A COOLING ONLY

Indoor Unit
• Auto Random Restart • Golden fin
• Low noise • Long distance wind blast
• Washable air filter • 3D air flow
• Sleep Mode
• Easy maintenance
• Self-diagnosis and Auto-protection
• Manual or Wireless controller

Remote Control
• 4 operation modes: Auto, Cool, Dry, Fan only
• Multi-speed fan setting: High/Medium/Low/Auto
• 24-hour timer setting
• Turbo cool setting
• Background light LCD display
• Real-time clock display
• Follow me

Condensing Unit
• 3-minute protection
• Compact size • Valve protection
• More sturdy and durable • Easier installation
• High efficiency compressor • Easier maintenance
• Low noise • Golden fin

The YORK® line of Floor Standing Air conditioners includes a wide range of sizes
to meet many customers’ needs. Each model is designed to provide comfort and
efficiency, in an easy-to-operate unit and flexible installation makes them an easy
fit for a variety of applications. Models meet the highest energy efficiency ratings,
so less energy is consumed without sacrificing comfort and performance. Both the
condensing and indoor units are engineered for quiet operation. And comfort control
settings are easily changed with the touch of a button on the remote control.

2
24 Hour Timer 3 Minutes Protection
Allows programmed start times up to A 3-minute delay before the
24 hours in advance for flexible and compressor will restart helps
more convenient operation. avoid compressor damage and
24
extend compressor life.
FLOOR STANDING TROPICAL 60HZ R-410A COOLING ONLY

Electrical Defrosting
Child Lock Automatic deicing of outdoor unit
If the lock button on the remote below certain temperatures helps
control is pressed, it must be
Features and benefits pressed again before use, which
ensure proper operation, saves
energy and improves efficiency.
helps prevent accidental operation. (Heat pump only)

Multi-Speed Fan Washable Filter


Multi-speed fan helps satisfy various airflow Washable filter allows for convenient service and Heating at -20°C
Weekly Timer Low Ambient
requirements. maintenance.
Optional weekly timer allows for The AC will run in heating mode
customized programming of on/off when outdoor temperature is belo
times each day of the week for 20°C to meet special user-reques
more flexible and convenient -20oC applications. (Heat pump only)
operation.

3-Minute Protection
3 Minutes Protection Auto Restart Low Ambient Cooling at -15°C
Auto restart The AC will run in cooling mode
p to
nd
A 3-minute delay before the compressor will
A 3-minute delay before the
AUTO Unit is automatically returned to previous
Unit is automatically returned to when outdoor temperature is
compressor will restart helps previous operating conditions after below -15°C to meet special
restart helps avoid compressor damage and
avoid compressor damage and
operating conditions after a power outage,
a power outage, for simplified for applications.
user-requested
extend compressor life.
-15 C
work time.
o
operation. (Cooling only. Standard for
simplified operation. Unitary Smart DC inverter types.
Optional for others.)

Electrical Defrosting
Automatic deicing of outdoor unit
24-Hour Timer
below certain temperatures helps
24 Hour Timer
ensure proper operation, saves 3 Minutes Protection
Self Diagnosis
Allows programmed start times up to
n. Allows programmed start times up to 24Acompressor
energy and improves efficiency.
24 hours in advance for flexible and
(Heat pump only)
hours
3-minute delay before the
will restart helps
Clearly displayed failure codes allow for quicker
24
more convenient operation.
in advance for flexible and more convenient
avoid compressor damage and
extend compressor life.
troubleshooting and easier maintenance.
operation.
Low Ambient Heating at -20°C
The AC will run in heating mode
ff when outdoor temperature is below Electrical Defrosting
Child
20°C to Lock
meet special user-requested Automatic deicing of outdoor unit
-20oC Ifapplications.
the lock button
(Heatonpump
the remote
only) below certain temperatures helps
control is pressed, it must be ensure proper operation, saves
pressed again before use, which energy and improves efficiency.
helps prevent accidental operation. (Heat pump only)

Low Ambient Cooling at -15°C


The AC will run in cooling mode
when outdoor temperature is
er below -15°C to meet special Low Ambient Heating at -20°C
Weekly Timer
-15oC
user-requested applications.
Optional weekly timer allows for
(Cooling only. Standard for
Golden fin
The AC will run in heating mode
when outdoor temperature is below
customized programming of on/off
Unitary Smart DC inverter types. 20°C to meet special user-requested
times each day of the week for
Optional for others.)
more flexible and convenient
operation.
-20oC The unique anticorrosive golden coating on the heat exchangers
applications. (Heat pump only)

can withstand the salty air, rain and other corrosive elements.
It also effectively prevents bacteria from breeding and improves
Low Ambient Cooling at -15°C
Auto restart The AC will run heat
in coolingefficiency.
mode
Unit is automatically returned to when outdoor temperature is
AUTO
previous operating conditions after below -15°C to meet special
a power outage, for simplified user-requested applications.
operation. -15oC (Cooling only. Standard for
Unitary Smart DC inverter types.
Optional for others.)

3
Specification
YORK Model YLFE60BZH3CMSR5
YORK Outdoor YLFE60BYH3CMS-5
YORK Indoor YLFE60BXH3CM-R5
Power supply V-Hz-Ph 230-60-1
Power supply by Outdoor
Capacity Btu/h 51,000/43,000
Input W 4,113/5,000
Cooling (T1/T3)
Rated current A 18.33/22.21
EER Btu/(h∙W) 12.4/8.6
Max. input consumption W 6,600
Max. current A 35
Starting current A 120
Type SCROLL
Rated current(RLA) A 19.50
Locked rotor Amp(LRA) A 120
Compressor
Thermal protector position INTERNAL
Capacitor uF 70
Refrigerant oil/oil charge ml POE/1,360
Type DC
Indoor fan motor Output W 200
Speed(Hi/Mi/Lo) rpm 530/490/460
Indoor air flow (Hi/Mi/Lo) m3/h 2,430/2,230/2,065
Indoor noise level (Hi/Mi/Lo) dB(A) 52/50/49
Dimension(WxHxD) mm 629x1,935x456
Indoor unit Packing (WxHxD) mm 750x2,055x575
Net/Gross weight kg 58.8/78.8
Type DC
Outdoor fan motor Output W 170
Speed rpm 850
Outdoor air flow (Hi) m3/h 7,800
Outdoor noise level dB(A) 65
Dimension(WxHxD) mm 1,120x1,558x528
Outdoor unit Packing(WxHxD) mm 1,270x1,700x575
Net/Gross weight kg 130.8/148.1
Refrigerant/charge g R-410A/4,800
Liquid side/ Gas side mm(inch) Ø9.52/Ø22(3/8"/7/8")
Max. refrigerant pipe length m 50
Refrigerant piping Max. difference in level m 30
standard connection pipe length m 5
Additional refrigerant g/m 30x(Length-5)
Operation temperature range °C 17-30
Ambient temperature range (cooling) °C 18-52
Application area m2 70-102
Qty’per 20’ /40’ /40'HQ Set 13/28/30
Nominal testing conditions @ T1:
Cooling - Indoor 80.6°F DB / 66.2°F WB (27°C DB / 19°C WB) & Outdoor 95°F DB / 75.2°F WB (35°C DB / 24°C WB)
Nominal testing conditions @ T3:
Cooling - Indoor 84.2°F DB / 66.2°F WB (29°C DB / 19°C WB) & Outdoor 114.8°F DB / 75.2°F WB (46°C DB / 24°C WB)

*This product is coming with holding refrigerant charge from the factory. Refrigerant charge must be checked before startup to assure design performance.

Johnson Controls, the Johnson Controls logo, YORK are registered trademarks of Johnson Controls, Inc in the United States of America and other countries. Other
trademarks used herein may be trademarks or registered trademarks of other companies.
FOR MORE INFORMATION CONTACT JOHNSONCONTROLS.COM
© 2020 Johnson Controls, Inc, P.O. Box 423, Milwaukee, WI 53201, All rights reserved worldwide. PUBL-8376(1220)