Report No.

TUBE BUNDLE ALIGNMENT Date:


Shree Cemnet Ltd, Nawalgarh
Plant Name (Raj) QCP No.

Project No. HA-9013 Drawing No & Rev. HA-9013-12758 Rev.2

Project Name 180 TPH ACC erection & Cell No. Grid - B
Commissioning

SR. No. RHS TUBE LHS TUBE WATER REMARK


BUNDLE ROW BUNDLE ROW LEVEL
1 12592 mm 12592 mm CDH C/L to C/L
2 6296 mm 6296 mm C/L of A Frame
3 304 mm 304 mm Lower cond.
Duct c/l to TB
bottom length
4 1558 mm 1558 mm Height from TOC
to LCD C/L.
5
6

NOTE:

Holtec Representative Sign: Client representative Sign:


Name: Name:
Date: Date: