You are on page 1of 2

87045 LIMOGES Cedex

Telephone: +33 (0)5 55 06 87 87 - Fax: +33 (0)5 55 06 88 88

Cat. 6A LSOH cable for LCS2 Catalogue numbers: 0 327 78/98/99 - 0 328 78

CONTENTS Pages

F/UTP 1.
2.
Use . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Description . . . . . . . . . . . . . . . . . . . . . 1
3. Cable markings . . . . . . . . . . . . . . . . . . 1
4. Performance at 500 MHz . . . . . . . . . . 1
5. Technical and mechanical features . . . 2
6. Electrical features at 20°C . . . . . . . . . 2
7. Ordering information . . . . . . . . . . . . . . 2
F/FTP 8. Environmental features . . . . . . . . . . . . 2
9. Standards and approvals . . . . . . . . . . 2

1. USE 3. MARKING OF LEGRAND CABLES


Cat. 6A cables with 4 pairs and 2 x 4 twisted pairs, 100 ohms very - Legrand
high speed, for horizontal floor or backbone distribution. These cables - Catalogue number
enable the use of protocols supported by Class EA for 10G Base-T - Number of pairs
applications. They are characterised up to 500 MHz. - Gauge
- Type
- Impedance
- Type of sleeve
2. DESCRIPTION - Category
- Conformity to standards
- VPN/NVP
F/UTP 100 Ω (4 pair cable) - Batch number
- Measurement (remaining length)
Copper: Water-repellent
Ø > 0.56 mm synthetic tape

Insulation: solid PE Shielding: alumin/ 4.  PERFORMANCE AT 500 MHZ (standard ANSI/TIA 568-C.2)
Ø 1.10 mm polyester tape
Maximum attenuation (dB/100 m):................45.3
NEXT minimum (dB):....................................33.8
Pair Drain wire: PS NEXT (dB):..............................................31.8
tinned copper
ACRF (dB/100 m):.........................................13.8
X-shaped PS ACRF (dB/100 m):...................................10.8
Protection: Return Loss (dB):..........................................15.2
separator LSOH sleeve

F/FTP 100 Ω

8 conductors 4 pairs with an individual


aluminium tape sleeve
23 AWG with Pe insulation Ø 1.42 ± 0.03
on each pair

Drain

Aluminium sleeve
LSOH sleeve

Note:
The conductive part of the shielding is located on the wire side

Technical data sheet: F00989EN/04 Updated: 6/03/2014 Created: 28/09/2009

1/2
Cat. 6A LSOH cable for LCS2 Catalogue number: 0 327 78/98/99 - 0 328 78

5. TECHNICAL AND MECHANICAL FEATURES 7.  ORDERING INFORMATION

Cat. No. 0 327 78 0 328 78 0 327 99 0 327 98 Cat. No. 0 327 78/0 328 78 0 327 98/0 327 99
Type F/UTP F/UTP F/FTP F/FTP Type F/UTP F/FTP
Type of sleeve LSOH Colour Yellow RAL 1018
Number of pairs 4 2x4 4 2x4 Pack (m) 500
Assembly Pairs Packaging Reel
Diameter over 1.16 ± 0.05 1.10 1.42 ± 0.03 1.42 ± 0.03
insulation (mm)
Cable diameter (mm) 7.3 ± 0.3 6.30 x 13.30 7.5 ± 0.2 7.4 ± 0.1 x
15.55 ± 0.5
8.  ENVIRONMENTAL FEATURES
Weight of cable (kg/km) 51 95 > 53 > 109
Min. bending radius
when laying (mm)
60 50 ≥ 60 ≥ 60 Storage and transport temperature: 0 to +50°C
Usage temperature: -20 to +60°C
AWG gauge 23 24 23 23 Fire resistance: IEC 60332-1

9.  STANDARDS AND APPROVALS


6. ELECTRICAL FEATURES at 20°C
Cat 6A, 500 MHz
ANSI/TIA 568-C.2
EN 50173
Cat. No. 0 327 78 0 328 78 0 327 99 0 327 98 EN 50288
Type F/UTP F/FTP IEC 11801
IEC 61156-5
Maximum linear resistance IEC 60332-1-2
of the cable per strand 95 * IEC 61034-2
(ohm/km) IEC 60754

DC dielectric strength 1 kV/1 min *

Minimum insulation
resistance (Mohm.km) 5000

Minimum propagation speed


> 66% ≥ 78%
(marked on cable)

Characteristic impedance
100 ± 15%
from 1 to 100 MHz

* according to standard: IEC 61156-5

Technical data sheet: F00989EN/04 Updated: 06/03/2014 Created: 28/09/2009