You are on page 1of 1

SYSTEMS INC.

#7583 Vantage Place, Delta, B.C. V4G 1A5 Phone: (604) 584-4747
email:flame@iris-systems.com Fax: (604) 581-9790
Web site:www.iris-systems.com

APPLICATION NOTE #004


SCANNER CABLE SPECIFICATIONS

For series S55xB, S700 and S800 viewing heads, cable between processor and
viewing head is based on the following specifications.

For run up to 300 meters (1000 feet)

Number of conductors = 3+1 shielded

Conductor size and strands (unshielded)


1.29 mm dia or 1.3 sq.mm cross sectional area (16 Awg) 19 strands.

Conductor size and strands (Shielded)


1.29 mm dia or 1.3 sq.mm cross sectional area (16 Awg) and 19 strands.

Color Code – Unshielded - Black, Red and Green

Color Code Shielded - White

Conductor outside cover – All conductors


Crossed Linked – Polyethylene 0.45 mm (0.017 inches)

For shielded conductor


Shield shall be 36 awg braided to cover 90%+ of the conductor.
Braiding should be covered with 0.012” jacket –color black.

Overall Coverage
Crossed Linked Polyethylene and internal filled with Polypropylene to provide
roundness.

For distance longer than 300 meters (1000 feet), use similar cable with higher
gauge conductors.

•SAFETY FIRST •RELIABILITY ALWAYS • DISCRIMINATION GUARANTEED


Please call (510) 581-4738 if any of this transmission was not sent or illegible.