You are on page 1of 2

Project: hhghh General Notes:

Job No.: hhghh gkg


Client: yyy uyuu
Design by: uuu hgh
Date: tyyuy
Sheet: 2 Of 5
Jerv Works Const. Ref: Reinforced Concrete Design, 6th ed., pg. 316, by: Wang and Salmon
*Input data in green cells

ONE WAY SOLID SLAB


By strength design method of the ACI Code

Slab no. 2

12mm @ 130 mm c.c


12mm @ 130 mm c.c 12mm @ 130 mm c.c
12mm @ 130 mm c.c
1 m. 1 m.

h= 200 mm

12mm @ 130 mm c.c 12mm @ 130 mm c.c

temperature and shrinkage bar


12mm @ 280 mm c.c

specification
fc' 27 MPa
fy 276 Mpa

unfactored load
service dead load 4.00 kPa
service live load 2.40 kPa

slab
span 4.00 m Required min. h
h, slab depth 200.00 mm >= 165.62
conc. cover 25.00 mm

R-bars to use
Phils. Standard Reinforcing Bars

main bar temp. bar


12mm 12mm
to reduced deflection, suggested
p = .30 of .75Pb
reinforcement ratio
.75Pb > p > 1.4/fy
0.0363 >= 0.006 >= 0.0051
solution:
slab DL=h*1*sp. gr. Of concrete*wt. of water 4.71 kPa
total DL 8.71 kPa
Wu=1.4DL + 1.7LL 16.27 kPa
V=w*L*c
shear M right M left M right
M left support mid-span mid-span
23/40 support support support
37 1/10 1/14 1/10 1/12 1/16 1/12
Mu = cwl2, in N-m 26036 18597 26036 21696 16272 21696
Mn=Mu/.90, N-m 28,929 20,663 28,929 24,107 18,080 24,107

max Mu= 26,035.71 N-m


Mn = Mu/.90 28,928.57 N-m
B1 0.85
Pb = .85fc'B1/fy[87000/(87000+fy)] 0.0484
Pmax = .75Pb 0.0363
Pmin = 1.4/fy 0.005
adapted P 0.006
m = fy/.85fc' 12.03
Rn = Pfy(1-Pm/2) 1.60 Mpa
required d = sqrtMn/(b*Rn) 134.62 mm
h = d+conc. cover+bar dia/2 165.62 mm
min h for deflection = L/30 133.33 mm
min. h for fire resistive requirements 130.00 mm
required min h 165.62 mm
actual h 200.00 mm
actual d 169.00 mm

req. Rn=Mn/bd^2 1.01 0.72 1.01 0.84 0.63 0.84


P=1/m(1-sqrt(1-2mRn/fy)) 0.003754583 0.002663971 0.00375458 0.00311659 0.002326173 0.00311659
hence p (consd'ring min p) 0.0051 0.0051 0.0051 0.0051 0.0051 0.0051
req. As=Pbd 861.90 861.90 861.90 861.90 861.90 861.90
spacing of bar 130.00 130.00 130.00 130.00 130.00 130.00

shrinkage and temperature reinforcement


As = .002bt 400.00 mm2/m
spacing = Ab*1000/As 280.00 mm2/m
or s = 5t 1,000.00 mm
or s = 450 mm 450.00 mm
280.00 mm2/m

Phils. Standard Reinforcing Bars temp. bar area dia.


main bar area dia. 6mm 28.27 6
6mm 28.27 6 10mm 78.54 10
10mm 78.54 10 12mm 113.1 12
12mm 113.10 12 113.1 12
16mm 201.1 16
20mm 314.2 20 ASTM Standard Reinforcing Bars
25mm 491.90 25 Phils. Standard Reinforcing Bars
28mm 615.75 28
32mm 804.25 32
113.10 12

You might also like