Load and Resistance Factor Design (LRFD)
(203-1) 1.4 (D + F)
(203-2) 1.2 (D + F + T) + 1.6 (L + H) + 0.5 (Lr or R)
(203-3) 1.2 (D) + 1.6 (Lr or R) + (f1L or 0.8W)
(203-4) 1.2 (D) + 1.6 (W) + f1L + 0.5 (Lr or R)
(203-5) 1.2 (D) + 1.0 (E) + f1L
(203-6) 0.9 (D) + 1.6 (W) + 1.6 (H)
(203-7) 0.9 (D) + 1.0 (E) + 1.6 (H)
C. Live Loads
ᴥ Residential
Basic Floor Area 1.90 kPa
Exterior balconies 2.90 kPa
Decks 1.90 kPa
Storage 1.90 kPa
ᴥ Office 2.40 kPa
ᴥ Toilets 2.40 kPa
ᴥ Classroms, Laboratory 1.90 kPa
ᴥ Dining Rooms and Restaurants 4.80 kPa
ᴥ Hospitals
Wards and Rooms 1.90 kPa
Lab and Operating Rooms 2.90 kPa
Corridors above ground floor 3.80 kPa
ᴥ Libraries
Reading Rooms 2.90 kPa
Stack Rooms 7.20 kPa
Corridors above ground floor 3.80 kPa
ᴥ Stairs 3.80 kPa
ᴥ Corridors on Ground 4.80 kPa
ᴥ Roof 1.00 kPa