Product

Catalogue

2016-2017
Introduction

Galland is a French company who acquired more than 70 years of expertise in


the rail sector especially in the overhead line equipement (cantilevers, automatic
tensioning device, section insulators, fittings, jumpers, droppers, rigid catenary).
This experience is the fruit of hours of research and development by our
design office in close collaboration with our partners and customers.
Therefore the company is approved for a wide range of products for
conventional lines, high speed lines, metros and tramways.

Galland family founded the company in 1 946.

In 1 961 , the founders of the company set up a new company: THE BELIER
FOUNDRIES AND WORKSHOPS to satisfy our customers' needsin order to answer the
inquiries of our customers. Today the BELIER FOUNDRIES and GALLAND belong to
“Le BELIER PARTICIPATION holding” owned by the Galland family.
In 1 987 Galland started to export its products with its first contract in China.
In 2003 the company moved to south west of France, close to Bordeaux, in a
brand new factory.
Since this date the strategy of Galland is to work in closest collaboration with
its partners and customers in order to share its 70 years of experience in the catenary
sector, helping them and developing specific and innovative solutions according to the
local specifications and needs.
Today Galland is working under the ISO 9001 certification ; employing
approximatly 45 people.

Some of our main references for tramways, conventional and high speed train
lines:
m Europe : France, Germany, England, Belgium, Croatia, Norway, Portugal, Czech
Rep., Spain, Luxembourg, Turkey, Greece , Bulgaria

m Africa : Algeria, Morocco, Tunisia


m America : United States, Canada, Argentina, Brazil, Mexico
m Oceania : Australia , New Zealand
m Asia : China, South Korea, Hong kong, Japan, Malaysia, Taiwan
m India
m Middle East : Israel, Egypt

- Galland Catalogue - 3
4 - Galland Catalogue -
Table of Contents

- Galland Catalogue - 5
6 - Galland Catalogue -
AUTOMATIC
TENSIONING
DEVICES

- Galland Catalogue - 7
Automatic Tensioning Device 1/3
Wheels Version

Application
Wheels Tensioning Devices are used to apply a constant mechanical load in catenaries (contact wire
and messenger wire, together or independently) according to the variation of temperature and the length defined.

Description
A With a specific stainless steel non rotating wire Ø8,75
A Individual grease hole on each pulley

Compliance
A EN 5011 9

Options
A Stop fall device to avoid to the counterweights falling down (if the contact/messenger wire breaks); avoid
the contact/messenger wire to fall down (in case of breaking of the Automatic Tensioning Device
wire[vandalism])
A Graduated scale (visual control of the wire expansion from the ground)
A Counterweights: cast iron or concrete (different form and size for external use, integrated in a pole or for
special tunnel use). See the counterweight Data-Sheet for more information
A Ball bearings greased for life - no more greasing operation during the maintenance cycle

8 - Galland Catalogue -
Automatic Tensioning Device 1/3
Wheels Version

Main Sales References:


A England, Turkey, Morocco, Norway, India, Germany, Malaysia

Tests Type:
A Mechanical Test
A Efficiency Test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

- Galland Catalogue - 9
Automatic Tensioning Device 1/4
Wheels Version

Application
Wheels Tensioning Devices are used to apply a constant mechanical load in catenaries (contact wire
and messenger wire, together or independently) according to the variation of temperature and the length defined.

Description
A With a specific stainless steel non rotating wire Ø8,75
A Individual grease hole on each pulley

Compliance
A EN 5011 9

Options
A Stop fall device to avoid to the counterweights falling down (if the contact/messenger wire breaks); avoid
the contact/messenger wire to fall down (in case of breaking of the Automatic Tensioning Device
wire[vandalism])
A Graduated scale (visual control of the wire expansion from the ground)
A Counterweights: cast iron or concrete (different form and size for external use, integrated in a pole or for
special tunnel use). See the counterweight Data-Sheet for more information
A Ball bearings greased for life - no more greasing operation during the maintenance cycle

10 - Galland Catalogue -
Automatic Tensioning Device 1/4
Wheels Version

Main Sales References:


A France, England, Turkey, Morocco, Norway, India, Germany, Malaysia

Tests Type:
A Mechanical Test
A Efficiency Test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

- Galland Catalogue - 11
Automatic Tensioning Device 1/5
Wheels Version

Application
Wheels Tensioning Devices are used to apply a constant mechanical load in catenaries (contact wire
and messenger wire, together or independently) according to the variation of temperature and the length defined.

Description
A With a specific stainless steel non rotating wire Ø8,75
A Individual grease hole on each pulley

Compliance
A EN 5011 9

Options
A Stop fall device to avoid to the counterweights falling down (if the contact/messenger wire breaks); avoid
the contact/messenger wire to fall down (in case of breaking of the Automatic Tensioning Device
wire[vandalism])
A Graduated scale (visual control of the wire expansion from the ground)
A Counterweights: cast iron or concrete (different form and size for external use, integrated in a pole or for
special tunnel use). See the counterweight Data-Sheet for more information
A Ball bearings greased for life - no more greasing operation during the maintenance cycle

12 - Galland Catalogue -
Automatic Tensioning Device 1/5
Wheels Version

Main Sales References:


A France, Morocco, India, Germany, UK, Spain, Brazil

Tests Type:
A Mechanical Test
A Efficiency Test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

- Galland Catalogue - 13
Automatic Tensioning Device
Spring Version

Application
Spring Tensioning Devices are used to apply a mechanical load in catenaries for the crossovers.
General length compensation: up to 1 20m for delta of temperature of 70°C (we can double the length).

Description
A Spring version protected in an stainless steel tube
A Adjustment abacus provided with each ATD (Automatic Tensioning Device)
A Mostly used on tramways networks (crossovers and depots)

Compliance
A EN 5011 9

Main Sales References:


A France, UK, Italy, Spain, Algeria, Norway, Morocco

Tests Type:
A Mechanical Test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications
14 - Galland Catalogue -
Automatic Tensioning Device
Gas Version

Application
Gas Tensioning Devices (AERO), without counterweight, are used to apply a constant mechanical load
in catenaries (contact wire et messenger wire, together or independently) according to the variation of
temperature in range defined in the specifications.
By analogy with a wheels tensioning device, we can make the following parallel:
A As the tension depends on the counterweight with a wheels TD, it depends exclusively on the gaz
pressure in the AERO.
A X dimension between wheels in the wheels TD is replaced by the X dimension of the piston stroke of the
AERO

Description
A Gaz used : nitrogen (N2) ; Inert, it composed 70 % of the ambient air
A Protective equipment over the piston
A Solutions equipped with 2 sensors (gas pressure, stroke length)
A Options : Graduated scale for checking from the ground ; safety span

Compliance
A PED (97/23/EC)

Already Installed:
A France : RATP Paris (T2), Tramway Dijon, Nice, Grenoble,
Besançon, Montpellier
A Light Metro Cuiaba Brazil
A Testing line Korea
Tests Type:
A Mechanical Test
Those tests are available on demand.
We are ready to proceed to other Approval Tests in order to follow your local specifications

- Galland Catalogue - 15
Counterweights
For Automatic Tensioning

Application
The total weight of the counterweights associated with the Automatic Tensioning Device ratio will define
the mechanical tension applied to the wire.

Description
A Piece of 20, 40 kgW in cast iron or concrete
A Three different versions :
B Railway use : outdoor
B Tunnel use : reduced space use (ex : to integrating it them in walls)
B Tramway use : inside the poles in cities

16 - Galland Catalogue -
SECTION
INSULATORS

- Galland Catalogue - 17
750V D.C. - Section Insulator

Application
Section insulators (S.I.) are used for the electrical segmentation of the catenary to divide the line in
different sections for lines operation and maintenance.

Description
A New version equipped with arcing horns and new runners profile on the CW for a better dynamic
crossing.
A For one or two contact wires (CW) in BC1 07, BC1 20 or BC1 50 sq.mm according to EN 501 49.
For specific requests, please contact us and let us know the design of clamping grooves, CW profile
and specific standard
A Bi-directional crossing
A Light and compact

Compliance
A EN 5011 9
A Many technical approvals all around the world (France, Spain, Belgium, UK, Norway, Argentina, IsraelW)

Sparte parts
Connecting kit for Suspensions (Connecting Sleeves / Thimble / Turnbuckle / Suspension Brace / Stainless
cableW) => JG31 44

18 - Galland Catalogue -
750V D.C. - Section Insulator

Main Sales References:


A France, Spain, Belgium, UK, Norway, Argentina, Israel, Algeria, ChinaW

Tests Type:
A Mechanical Test
A Electrical performances test
A Arc extinguishing test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

Our Design Team is able to create any needs you may have.

What specifications do they need?


B Section of wire / Standard of wire / Number of contact wires
B Electrical & Mechanical tension
B Distance between CW and MW
B Speed operation of the line (unilateral or bilateral directions)

Do not hesitate to contact us for more details or others references (info@galland-sas.com)


- Galland Catalogue - 19
1,5 – 3 kV D.C. - Section Insulator

Application
Section insulators (S.I.) are used for the electrical segmentation of the catenary to divide the line in
different sections for lines operation and maintenance.

Description
A Mechanical and electrical continuity ensured during dynamic negotiation of the S.I. by the locomotive
through metallic runners
A New version equipped with arcing horns and new runners profile on the CW for a better dynamic crossing
A For one or two contact wires (CW) in BC1 07, BC1 20 or BC1 50 sq.mm according to EN 501 49.
For specific requests, please contact us and let us know the design of clamping grooves, CW profile
and specific standard
A Bi-directional crossing
A Light and compact

Compliance
A EN 5011 9
A Technical approvals all around the world (France, Australia, Belgium, Brazil, Czech Republic, Spain,
Morocco, Norway, USA).

Sparte parts
Connecting kit for Suspensions (Connecting Sleeves / Thimble / Turnbuckle / Suspension Brace / Stainless
cableW) => JG31 44.

20 - Galland Catalogue -
1,5 – 3 kV D.C. - Section Insulator

Main Sales References:


A France, Australia, Belgium, Brazil, Czech Rep, Spain, Morrocco, Norway, USA, South Africa,
Hong Kong

Tests Type:
A Mechanical Test
A Electrical performances test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

Our Design Team is able to create any needs you may have.

What specifications do they need?


B Section of wire / Standard of wire / Number of contact wires
B Electrical & Mechanical tension
B Distance between CW and MW
B Speed operation of the line (unilateral or bilateral directions)

Do not hesitate to contact us for more details or others references (info@galland-sas.com)


- Galland Catalogue - 21
1,5 – 3 kV D.C. - Section Insulator

Application
Section insulators (S.I.) are used for the electrical segmentation of the catenary to divide the line in
different sections for lines operation and maintenance.

Description
A For installation on main line and crossovers up to 1 60 km/h
A Mechanical and electrical continuity ensure during dynamic negotiation of the S.I. by the locomotive
through metallic runners
A For one or two contact wires (CW) in BC1 07, BC1 20 or BC1 50 sq.mm according to EN 501 49
For specific requests, please contact us and let us know the design of clamping grooves, CW profile
and specific standard
A Negotiation with a preferential way
A Light and compact
A Available for one or two contact wires

Compliance
A EN 5011 9
A Many technical approvals all around the world (France, Germany, Spain, Korea, ChinaWetc).

Option
A With accessories on Messenger Wire (MW) including dropper clamps, collar sockets, insulator.

Sparte parts
Connecting kit for Suspensions (Connecting Sleeves / Thimble / Turnbuckle / Suspension Brace / Stainless
cableW) => JG31 44.

22 - Galland Catalogue -
1,5 – 3 kV D.C. - Section Insulator

Main Sales References:


A For Conventional Lines: China

Tests Type:
A Mechanical Test
A Electrical performances test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

Our Design Team is able to create any needs you may have.

What specifications do they need?


B Section of wire / Standard of wire / Number of contact wires
B Electrical & Mechanical tension
B Distance between CW and MW
B Speed operation of the line (unilateral or bilateral directions)

Do not hesitate to contact us for more details or others references (info@galland-sas.com)


- Galland Catalogue - 23
1,5 – 3 kV D.C. - Section Insulator

Application
Section insulators (S.I.) are used for the electrical segmentation of the catenary to divide the line in
different sections for lines operation and maintenance.

Description
A Mechanical and electrical continuity ensure during dynamic negotiation of the S.I. by the locomotive
through metallic runners
A For one or two contact wires (CW) in BC1 07, BC1 20 or BC1 50 sq.mm according to EN 501 49.
For specific requests, please contact us and let us know the design of clamping grooves, CW profile
and specific standard
A Bi-directional crossing
A Light and compact

Compliance
A EN 5011 9

Option
A With accessories on Messenger Wire (MW) including dropper clamps, collar sockets, insulator

Sparte parts
Connecting kit for Suspensions (Connecting Sleeves / Thimble / Turnbuckle / Suspension Brace / Stainless
cableW) => JG31 44

24 - Galland Catalogue -
1,5 – 3 kV D.C. - Section Insulator

Main Sales References:


A China, Australia, South Africa

Tests Type:
A Mechanical Test
A Electrical performances test

Those tests are available on demand.


We are available to proceed to other Approval Tests in order to follow your local specifications

Our Design Team is able to create any needs you may have.

What specifications do they need?


B Section of wire / Standard of wire / Number of contact wires
B Electrical & Mechanical tension
B Distance between CW and MW
B Speed operation of the line (unilateral or bilateral directions)

Do not hesitate to contact us for more details or others references (info@galland-sas.com)


- Galland Catalogue - 25
1,5 – 3 kV D.C. - Section Insulator

Application
Section insulators (S.I.) are used for the electrical segmentation of the catenary to divide the line in
different sections for lines operation and maintenance.

Description
A For installation on main line, crossovers and depot for conventional lines up to 1 20 km/h in the preferred
direction (max. 80 km/h in opposite direction)
A Mechanical and electrical continuity ensure during dynamic negotiation of the S.I. by the locomotive
through metallic runners
A For one or two contact wires (CW) in BC1 07, BC1 20 or BC1 50 sq.mm according to EN 501 49.
For specific requests, please contact us and let us know the design of clamping grooves, CW profile
and specific standard
A Crossable with a preferential way

Compliance
A EN 5011 9

Option
A With accessories on Messenger Wire (MW) including dropper clamps, collar sockets, insulator

Sparte parts
Connecting kit for Suspensions (Connecting Sleeves / Thimble / Turnbuckle / Suspension Brace / Stainless
cableW) => SUS11 640-201

26 - Galland Catalogue -
1,5 – 3 kV D.C. - Section Insulator

Main Sales References:


A For conventional Lines : France, Australia, Morocco, Portugal, Mexico, Singapore, Hong Kong

Tests Type:
A Mechanical Test
A Electrical performances test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

Our Design Team is able to create any needs you may have.

What specifications do they need?


B Section of wire / Standard of wire / Number of contact wires
B Electrical & Mechanical tension
B Distance between CW and MW
B Speed operation of the line (unilateral or bilateral directions)

Do not hesitate to contact us for more details or others references (info@galland-sas.com)


- Galland Catalogue - 27
25 kV A.C. - Section Insulator
High Speed

Application
Section insulators (S.I.) are used for the electrical segmentation of the catenary to divide the line in
different sections for lines operation and maintenance.

Description
A For installation on main line and crossovers up to 220 km/h
A For installation in depot see our reference JG2202
A For one contact wire (CW) in BC1 07, BC1 20 or BC1 50 sq.mm according to EN 501 49
For specific requests, please contact us and let us know the design of clamping grooves, CW profile
and specific standard
A Bi-directional crossing
A Specific two contact wires version available
A High Speed Lines approved

Compliance
A EN 5011 9, CEI611 02
A SNCF 350 km/h speed specification
A Technical approvals all around the world (France, Germany, Spain, Korea, ChinaWetc)

Option
A With accessories on Messenger Wire (MW) including dropper clamps, collar sockets, insulator

Sparte parts
Connecting kit for Suspensions (Connecting Sleeves / Thimble / Turnbuckle / Suspension Brace / Stainless
cableW) => JG31 44

28 - Galland Catalogue -
25 kV A.C. - Section Insulator

Main Sales References:


A For High Speed Lines : France, Spain, Germany, Korea
A For Conventional Lines: Luxembourg, Portugal, Canada, UK, England, Taiwan, India, Australia,
Greece, Romania, Bulgaria MalaysiaW

Tests Type:
A Mechanical Test A Short circuit test
A Electrical performances test A Arc extinguishing test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

Our Design Team is able to create any needs you may have.

What specifications do they need?


B Section of wire / Standard of wire / Number of contact wires
B Electrical & Mechanical tension
B Distance between CW and MW
B Speed operation of the line (unilateral or bilateral directions)

Do not hesitate to contact us for more details or others references (info@galland-sas.com)


- Galland Catalogue - 29
25 kV A.C. - Section Insulator
Low Speed

Application
Section insulators (S.I.) are used for the electrical segmentation of the catenary to divide the line in
different sections for lines operation and maintenance.

Description
A For installation on main line but mainly in depot & crossovers up to 1 20 km/h in the preferred way
direction (max. 90 km/h in opposite direction)
A This section insulator insures the electrical continuity during the dynamic crossing
A For one contact wire (CW) in BC1 07, BC1 20 or BC1 50 sq.mm according to EN 501 49
For specific requests, please contact us and let us know the design of clamping grooves, CW profile
and specific standard
A This version is recommended for installation in depot because of its electrical configuration which can
compensate temporary overvoltages or harmonic currents generated by switching operation
A Crossable with a preferential way

Compliance
A EN 5011 9
A Technical approvals all around the world (France, Spain, Malaysia, Taiwan, Mexico, Turkey.Wetc)

Option
A With accessories on Messenger Wire (MW) including dropper clamps, collar sockets, insulator

Sparte parts
Connecting kit for Suspensions (Connecting Sleeves / Thimble / Turnbuckle / Suspension Brace / Stainless
cableW) => JG31 44

30 - Galland Catalogue -
25 kV A.C. - Section Insulator

Main Sales References:


A Export : Spain, Malaysia, Taiwan, Mexico, Turkey, Inde, Bulgarie
A France : SNCF and EUROTUNNEL

Tests Type:
A Mechanical Test
A Electrical performances test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

Our Design Team is able to create any needs you may have.

What specifications do they need?


B Section of wire / Standard of wire / Number of contact wires
B Electrical & Mechanical tension
B Distance between CW and MW
B Speed operation of the line (unilateral or bilateral directions)

Do not hesitate to contact us for more details or others references (info@galland-sas.com)


- Galland Catalogue - 31
25 kV A.C. - Section Insulator
"330 mm air gap"

Application
Section insulators (S.I.) are used for the electrical segmentation of the catenary to divide the line in
different sections for lines operation and maintenance.

Description
A For installation on main line and crossovers up to 220 km/h
A For installation in depot see our reference JG2202
A For one contact wire (CW) in BC1 07, BC1 20 or BC1 50 sq.mm according to EN 501 49
For specific requests, please contact us and let us know the design of clamping grooves, CW profile
and specific standard
A Bi-directional crossing
A Mechanical and electrical continuity ensured through metallic runners and composite shoes during the
crossing by the pantograph

Compliance
A EN 5011 9

Option
A With accessories on Messenger Wire (MW) including dropper clamps, collar sockets, insulator

Sparte parts
Connecting kit for Suspensions (Connecting Sleeves / Thimble / Turnbuckle / Suspension Brace / Stainless
cableW) => JG31 44

32 - Galland Catalogue -
25 kV A.C. - Section Insulator
"330 mm air gap"

Main Sales References:


A Norway, India

Tests Type:
A Mechanical Test
A Electrical performances test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

Our Design Team is able to create any needs you may have.

What specifications do they need?


B Section of wire / Standard of wire / Number of contact wires
B Electrical & Mechanical tension
B Distance between CW and MW
B Speed operation of the line (unilateral or bilateral directions)

Do not hesitate to contact us for more details or others references (info@galland-sas.com)


- Galland Catalogue - 33
PHASES SEPARATION SECTION
(short neutral section)

Application
Phase separation section is required between two substations in order to avoid electrical
interconnection from phase displacement in AC voltage supply.
Phase separation section is obtained in the catenary system by setting up a neutral section to separate
different electrical feeding sections.
Neutral section assembly is one of the main critical point in a railway network because of the potential
lack of respect of the switch-off power execution when the train driver crosses the separation section.

Option
A With accessories on Messenger Wire (MW) including dropper clamps, collar sockets, insulator

Sparte parts
Connecting kit for Suspensions (Connecting Sleeves / Thimble / Turnbuckle / Suspension Brace / Stainless
cableW) => JG31 44
Runners (stainless steel and composite)

34 - Galland Catalogue -
PHASES SEPARATION SECTION
(short neutral section)

Versions

If the neutral section is crossed with a pantograph uplifted and with current collection (VCB close), an
electrical arc will be generated which we will have to extinguish through our four units assembly.

A Two arc creating and extinguishing section insulators (for bidirectionnal crossing)
A Two neutral section insulators

Main References
A Testing :
B Australia, QLD, 201 0
A Sales :
B SNCF according to French specification
B India, 201 3 - 23 units

Type Tests Approvals:

A Mechanical test A Electrical performances test


A Short-Circuit test

- Galland Catalogue - 35
Tools and documentations
Section Insulator

Settings up notices and specific tools have been developed by The Galland Company in order to make
easier and faster the installation and the adjustment of the section insulators. A good installation and
adjustment will improve the crossing and the life time of the products.

36 - Galland Catalogue -
STEADY
ARMS

- Galland Catalogue - 37
STEADY ARMS - 750 V D.C.

Application
Steady arms are the main parts of the suspension of the contact wire on the cantilever. It adjusts the
stagger of the catenary.

Description
A Material:
M Galvanized steel or aluminium tubes, with or without insulation
M Reinforced rod in Glass Fiber Epoxy resin with synthetic cover
M Galvanized steel or copper alloy end fittings
A Assembled by compression
A Straight or curved

Compliance
A “Globally At Least Equivalent” Method

Version Available
A Possibility to add an adjustable head in order to correct the stagger of the line

38 - Galland Catalogue -
STEADY ARMS - 750 V D.C.

This table is just an overview of our main references


Specific development possible

Main Sales References:


A France, UK, Germany, Australia, Belgium, Spain, IrelandW

Tests Type:
A Mechanical Test
A Electrical Test (Insulated steady arms)

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

- Galland Catalogue - 39
STEADY ARMS - 1.5-3 kV D.C.

Application
Steady arms are the main part for the suspension of the contact wire on the cantilever. It adjusts the
stagger of catenary.

Description
A Material:
M Galvanized steel or aluminium tubes, with or without insulation
M Reinforced rod in Glass Fiber Epoxy resin with synthetic cover
M Galvanized steel or copper alloy end fittings
A Assembled by compression

Compliance
A Mechanical and electrical tests

Version Available
A Straight, Curved, Insulated, AdjustableW

40 - Galland Catalogue -
STEADY ARMS - 1.5-3 kV D.C.

This table is just an overview of our main references


Specific development possible

Main Sales References:


A France, UK, MorrocoW

Tests Type:
A Mechanical Test
A Electrical Test (Insulated steady arms)

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

- Galland Catalogue - 41
STEADY ARMS - 25 kV A.C.

Application
Steady arms are the main parts of the suspension of the contact wire on the cantilever. It adjusts the
stagger of catenary.

Description
A Material:
M Galvanized steel or aluminium tubes, with or without insulation
M Galvanized steel or copper alloy end fittings
A Assembled by compression

Compliance
A Mechanical tests

Version Available
A Straight, Curved, Adjustable, ReinforcedW

42 - Galland Catalogue -
STEADY ARMS - 25 kV A.C.

This table is just an overview of our main references


Specific development possible

Main Sales References:


A France, UK, Germany, Canada, Korea, India, Luxembourg, Portugal, Tunisia...

Tests Type:
A Mechanical Test

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

- Galland Catalogue - 43
STEADY ARMS
ADJUSTABLE HEAD

Application
Steady arms are the main parts of the suspension of the contact wire on the cantilever. It maintains the
stagger of catenary.
The main advantages for the adjustable head are :
M Adjustment of the position of the clamp on the contact wire
M Positioning and orientation of contact wire through the adjustable head thanks to the clamp in
order to improve the quality of crossing of pantograph under the section insulators

Description
A Galvanized steel adjustable head
A Available for most of our steady arm references

Compliance
A Mechanical and Electrical tests

44 - Galland Catalogue -
STEADY ARMS
ADJUSTABLE HEAD

This table is just an overview of our main references


Specific development possible

Main Sales References:


A France.

Tests Type:
A Mechanical Test
A Electrical test (insulated steady arms)

Those tests are available on demand.


We are ready to proceed to other Approval Tests in order to follow your local specifications

- Galland Catalogue - 45
46 - Galland Catalogue -
CANTILEVERS

- Galland Catalogue - 47
750 V D.C. Cantilever with
stainless steel stay wire and suspension delta

Application
Cantilever assemblies are used to hold the wires for the electrification of the line over the track.
Design will be different depending on the electrical tension and local technical specifications.
Stainless-steel solution is dedicated for a design with low maintenance costs.

Description
A Galvanised steel (painted) or aluminium tubes
A Stainless-steel wire delta (Ø5mm) and stays (Ø6mm)
A Copper alloy or aluminium fasteners
A Synthetic insulators.

References
A SNCF approval for tram-train design
A RATP approval in Paris
A "Low Maintenance" : more and more cities choose to switch from polyester wires to stainless steel
solutions to improve conditions of installation and maintenance

Our design team is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

We are fully ready to offer turnkey solution for tramway or light-metro cantilevers by covering almost all the components for
overhead electrification with possibility to assemble the parts according to individual data sheet per pole.

48 - Galland Catalogue -
3 kV D.C. Aluminium Cantilevers
Sliding Modular Cantilever System

Application
Cantilever assemblies are used to hold the wires for the electrification of the line over the track.
Design will be different depending on the electrical tension and local technical specifications.
3kV cantilever design is used in some countries due to local railway exeprience and networks.

Description
A Synthetic or ceramic insulators
A Aluminium tubes
A Aluminium extruded fasteners
A Optimized solution to makethe installation easier and faster
A Quick adjustement on site

References
A Poland (under approval process, )

Our design teal is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

We are fully ready to offer turnkey solution for tramway or light-metro cantilevers by covering almost all the components
for overhead electrification with possibility to assemble the parts according to individual data sheet per pole.

- Galland Catalogue - 49
25 kV A.C. Aluminium Cantilever

Application
Cantilever assemblies are used to hold the wires for the electrification of the line over the track.
Design will be different depending on the electrical tension and local technical specifications.
New fastening clamps on tubes to improve mechanical sliding behavior and make the instaltion
easier & faster.
Up to 220 km/h operating speed.

Description
A Aluminium tubes with aluminum extruded fastener parts (Ø 60, 70, 80W)
A Corrosion proof
A Lighter compare to steel tubes
A Easy to install because of weight and new design of fasteners
A No galvanization, no risk to damage galva thickness
A Standardization of the fastener parts to limit number of parts
A Cantilever insulators (creepage distance 1 200 or 1 600 mm)

Sales reference
A Aluminum design in Turkey, Algeria, Norway

Our design team is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

We are fully ready to offer turnkey solution for tramway or light-metro cantilevers by covering almost all the components
for overhead electrification with possibility to assemble the parts according to individual data sheet per pole.

50 - Galland Catalogue -
25 kV A.C. Steel Cantilever
"SNCF 85 type"

Application
Cantilevers make the triangulation of the catenary and hold the wires for the electrification of the line
over the track.
Design will be different depending on the electrical tension and local technical specifications.

Description
A Galvanised steel tubes
A Copper alloy fastener parts
A Proven SNCF design
A Up to 220 km/h operating speed

Sales reference
A All 220 km/h French lines, Morroco.

Our design team is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

We are fully ready to offer turnkey solution for tramway or light-metro cantilevers by covering almost all the components
for overhead electrification with possibility to assemble the parts according to individual data sheet per pole.

- Galland Catalogue - 51
25 kV A.C. Steel Cantilever
"350 km/h SNCF design"

Application
Cantilevers make the triangulation of the catenary and hold the wires for the electrification of the line
over the track.
Design will be different depending on the electrical tension and local technical specifications.

Description
A Galvanised steel tube s
A Copper alloy fastener parts
A Proven SNCF design
A Up to 350 km/h operating speed

Sales reference
A All 350km/h French high speed lines, Korea

Our design team is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

We are fully available to offer turnkey solution for tramway or light-metro cantilevers by covering almost all the
components for overhead electrification with possibility to assemble the parts according to individual data sheet per pole.

52 - Galland Catalogue -
750V O.C.S.
"LOW MAINTENANCE"
EQUIPMENT

- Galland Catalogue - 53
Stainless Steel
Flexible Cross Spans
«Low Maintenance»

Application
Flexible cross spans allow a mechanical and flexible connection from a steady arm or a contact wire to
a pole, a span or a façade.

Description
A Ø6 or Ø8mm stainless steel wire
A Solutions crimped to length in factory “ready to install” or “pre-assembled” to finish the adjustment on site
with manual end-fittings
A Possibility to adapt on all our steady arms (insulated or not, straight or curved, adjustableW)
A Solution for one or two steady arms
A Insulators in glass fibre and epoxy resin with silicone coatting
A Number of insulators depending on the needs and level of insulation

Reference
A Approved by SNCF for tram-train design.
A Approved by RATP in Paris.
A Tramways :
M Paris : T3 – T6 / Nantes / Bordeaux (France)
M Suzhou (China)
M Cuiabá (Brazil)

Our design team is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

GALLAND company is able to offer complete “tailor made” solutions for tramways or light metro projects, with the
possibility to make “pre-assembled” cantilevers following the data-sheet per pole catalog. The design of our
cantilevers covers the classic galvanized steel tubes, but also aluminium tubes for light solution with a lower
maintenance.

54 - Galland Catalogue -
Stainless Steel
Head Spans
«Low Maintenance»

Application
Head spans run over the track between poles or façades and are used to fix the suspension deltas
and steady arms.

Description
A Ø8 or Ø1 0mm stainless steel wire
A Solutions crimped to length in factory “ready to install” or “pre-assembled” to finish adjsutment on site
with manual end-fittings
A Insulators in glass fibre and epoxy resin with silicone cover
A Number of insulators depending on the needs and level of insulation (structural and electrical
clearances)

Reference
A Approved by SNCF for tram-train design.
A Approved by RATP in Paris.
A Tramways :
M Paris : T3 – T6 / Nantes / Bordeaux (France)
M Suzhou (China)
M Cuiabá (Brazil)

Our design team is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

GALLAND company is able to offer complete “tailor made” solutions for tramways or light metro projects, with
the possibility to make “pre-assembled” cantilevers following the data-sheet per pole catalog. The design of
our cantilevers covers the classic galvanized steel tubes, but also aluminium tubes for light solution with a
lower maintenance.

- Galland Catalogue - 55
Stainless Steel
Line Anchorings
«Low Maintenance»

Application
Anchoring slings anchor the contact wire to the tension device.
Stainless steel parts are privileged for a « low maintenance » design.

Description
A Ø1 0 mm stainless steel wire
A Solutions crimped to length in factory “ready to install” or “pre-assembled” to finish the adjustment on site
with manual end-fittings
A Insulators in glass fibre and epoxy resin with silicone coatting

Reference
A Approved by SNCF for tram-train design
A Approved by RATP in Paris
A Tramways :
M Paris : T3 – T6 / Nantes / Bordeaux (France)
M Suzhou (China)
M Cuiabá (Brazil)

Our design team is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

GALLAND company is able to offer complete “tailor made” solutions for tramways or light metro projects, with the
possibility to make “pre-assembled” cantilevers following the data-sheet per pole catalog. The design of our
cantilevers covers the classic galvanized steel tubes, but also aluminium tubes for light solution with a lower
maintenance.

56 - Galland Catalogue -
Stainless Steel
Suspension Deltas
«Low Maintenance»

Application
Suspensions deltas (mobile or fix version) keep a constant height of the contact wire all along the
line.

Description
A Ø5 mm stainless steel wire
A Solutions crimped to length in factory “ready to install”
A Insulators in glass fibre and epoxy resin with silicone coatting
A Different lengths available (contact us)

Reference
A Approved by SNCF for tram-train design
A Approved by RATP in Paris
A Tramways :
M Paris : T3 – T6 / Nantes / Bordeaux (France)
M Suzhou (China)
M Cuiabá (Brazil)
M Ouargla (Algeria)

Our design office is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

GALLAND company is able to offer complete “tailor made” solutions for tramways or light metro projects, with
the possibility to make “pre-assembled” cantilevers following the data-sheet per pole catalog. The design of
our cantilevers covers the classic galvanized steel tubes, but also aluminium tubes for light solution with a
lower maintenance.

- Galland Catalogue - 57
Stainless Steel
Middle Point Arrangement
«Low Maintenance»

Application
Middle point assembly is composed of two anchoring slings for anchoring on poles and a middle point
delta suspension on the contact wire.

Description
A Ø8 or Ø1 0mm stainless steel wire
A Solutions crimped to length in factory “ready to install” or “pre-assembled” to finish the adjustment on site
with manual end-fittings
A Insulators in glass fibre and epoxy resin with silicone coatting

Reference
A Approved by SNCF for tram-train design.
A Approved by RATP in Paris.
A Tramways :
M Paris : T3 – T6 / Nantes / Bordeaux (France)
M Suzhou (China)
M Cuiabá (Brazil)

Our design office is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

GALLAND company is able to offer complete “tailor made” solutions for tramways or light metro projects, with the
possibility to make “pre-assembled” cantilevers following the data-sheet per pole catalog. The design of our
cantilevers covers the classic galvanized steel tubes, but also aluminium tubes for light solution with a lower
maintenance.

58 - Galland Catalogue -
Cantilever Stays in
STAINLESS STEEL
«Low Maintenance»

Application
The stays hold the catenary cantilever over the track.

Description
A Ø6mm stainless steel wire
A Solutions crimped to length in factory “ready to install” or “pre-assembled” to finish the adjustment on
site with manual end-fittings
A Insulators in glass fiber and epoxy resin with silicone coatting

Reference
A Approved by SNCF for tram-train design.
A Approved by RATP in Paris.
A Tramways :
M Paris : T3 – T6 / Nantes / Bordeaux (France)
M Suzhou (China)
M Cuiabá (Brazil)

Our design office is able to customize the design according to local technical specification.
Do not hesitate to contact us for more details or others references (info@galland-sas.com)

GALLAND company is able to offer complete “tailor made” solutions for tramways or light metro projects, with
the possibility to make “pre-assembled” cantilevers following the data-sheet per pole catalog. The design of
our cantilevers covers the classic galvanized steel tubes, but also aluminium tubes for light solution with a
lower maintenance.

- Galland Catalogue - 59
Accessories
for Tramways

Insulator for Tramway :


Creepage distance : 1 50, 200 mm

Turnbuckles to crimp for


Tramway :
For stainlesse steel wire Ø6, Ø8,
Ø1 0 mm

Quick link for Tramway :


Ø6, Ø8, Ø9, Ø1 0, Ø1 2 mm

Reinforced fixing delta for


Tramway :
For tube Ø49 mm

Delta suspension clamp for


Tramway :
For wire Ø5 mm

Suspension dropper assembly for


Tramway :
For head span Ø6, Ø8, Ø1 0 mm
Ajsutement length 64mm (every 1 6mm)

This not an exhaustive list, do not hesitate to contact us for other


accessories for tramway lines
60 - Galland Catalogue -
L
DROPPERS

- Galland Catalogue - 61
62 - Galland Catalogue -
Monobloc Current Carrying Dropper

Application
Droppers are used on catenary overhead lines to fix the distance between messenger wire (MW)
and contact wire (CW). Our dropper can be used also as a current carrying dropper to make conductive the
individual droppers for high speed application and to limit the number of jumper connections & the weight on
CW.

Description
A Monobloc dropper clamps on MW and CW
A Mainly for :
M 65, 11 6 sq.mm MW
M CW according to EN 501 49 (1 07 to 1 50 sq.mm)
M Dropper wire in Bronze 1 2 sq.mm
A Could be crimped to lengths in factory based on distribution lengths
A Patented system

Type test approvals


A Breaking tests
A Cycling test (up to 2 million cycles according to SNCF specification and EN5011 9 standard)

Sales Reference
A France : Eurotunnel (outdoor platform).
A Algérie : Thenia - Tizi Ouzou

- Galland Catalogue - 63
Current Carrying Dropper

Raw Materials :
A Copper alloy

Messenger wire clamp

Contact wire clamp

Our Design Team is at your disposal for any specific need.


Do not hesitate to contact us for more details or others references (info@galland-sas.com).

64 - Galland Catalogue -
Current Carrying Dropper

Raw Materials :
A Copper alloy

Contact wire clamp Messenger wire clamp

Our Design Team is at your disposal for any specific need.


Do not hesitate to contact us for more details or others references (info@galland-sas.com).

- Galland Catalogue - 65
66 - Galland Catalogue -
CONNECTORS,
FITTINGS &
ACCESSORIES

- Galland Catalogue - 67
Fasterning Parts

Application
Fastening parts are used on catenary overhead lines to make the connections between tubes on
cantilevers.

Description
A Fastening parts made by extrusion of aluminum; easy to adapt to specific diameter

Main Sales References :


A Export: Norway, Turkey, Russia
A France : RATP

Type tests Approvals


A Breaking and sliding tests

68 - Galland Catalogue -
Anchoring Clamps

Application
Anchoring clamps are used on catenary overhead lines for the anchoring wires.

Description
A Working Load from 3kN to 25kN.
A Anchoring Clamp in stainless-steel.
A Wedge in bronze

Main Sales References


A Export: Taiwan, Russia

Type test approvals


A Breaking and fatigue tests

- Galland Catalogue - 69
Fastening and swivel parts
for cantilevers

Raw Materials : Raw Materials :


Copper Alloy Galvanised cast iron
Stainless steel screws

70 - Galland Catalogue -
SOLID
CONDUCTOR
RAIL

- Galland Catalogue - 71
S.C.R
Solid Conductor Rail
"Rigid Catenary"

Application

Solid Conductor Rail is mainly used today in tunnels, under bridges or maintenance workshop (with
retractable rigid catenary option) for special applications where encumbrance is reduced to limit the tunnel
cross sections which impacts direct the civil works budget.
Therefore S.C.R. is considered today as a cost saving solution for new railway electrification in
tunnels but also as a "low maintenance" solution.

Description

A Standard aluminium profile (11 0mm height version) offers an equivalent copper cross-section of
approx. 1 200 sq.mm which avoids installing additional feeders.
A No mechanical load applied on the contact wire comparing to tensioning device used with the flexible
catenary.

Design speed limitation with rigid catenary

A Most of the projects realized with S.C.R. are speed limited to 90 km/h or 1 20 km/h maximum. The
main reason of that limitation is that S.C.R. solution doesn’t offer enough flexibility to absorb the
vibration due to high speed.
A The only possibility to increase the speed with S.C.R. will consist to recover the condition of
operations of high speed flexible networks, i.e. by implementing a half-rigid overhead catenary.
This is obtained through our resilient suspension which uses a spring to compensate the uplift
when train is operated with higher speed.

72 - Galland Catalogue -
S.C.R
Solid Conductor Rail
"Rigid Catenary"

JG21 71 JG3430/PAC

JG3203

JG3536/1 02
Sales Reference

A France : SNCF and RATP in Paris for metro


A Spain (Barcelona metro), Italy (Torino depot), Korea (metro projects)

List of components dedicated for S.C.R.:

A Profile ramp to be installed at the end of each section length


A Transition profile from the flexible catenary to the rigid catenary
A Electrical connectors, Earthing clamps
A Expansion joint
A Steady arms
A Section insulators

Our Design Team is at your disposal for any specific need.


Do not hesitate to contact us for more details or others references (info@galland-sas.com)

- Galland Catalogue - 73
74 - Galland Catalogue -
Galland Tools Catalogue

Our tools catalogue is available on our website : www.galland-sas.com in the


download section.
You will find in it :

A PROTECTION EQUIPMENT AGAINST ELECTRICAL


DANGER
A PULLING AND LIFTING DEVICE

A CLIMBING TOOLS

A HYDRAULIC TOOLS

A MEASURING TOOLS
A CATENARY EQUIPMENT

A WORK SITE EQUIPMENT

A BONDS

A MACHINES

A MAINTENANCE PRODUCTS

- Galland Catalogue - 75
Galland SAS
255 ZI de L'ILLOT
33240 La Lande de Fronsac
France
Ph : +33 (0)5 57 94 07 20
Fax : +33 (0)5 57 94 07 11
www.galland-sas.com
info@galland-sas.com