Professional Documents
Culture Documents
3
EXFO : Telecommunications test equipment manufacturer
1
No. portable fiber testing
OTDR manufacturer
market
›OTDR : >45% market share and >125 000
units sold worldwide
›6th generation of OTDR and iOLM is the
future of fiber characterization
4
© 2010 EXFO Inc. All rights reserved. 4
PRESENCE IN MAJOR FTTX DEPLOYMENTS Design
Deployment ranking:
1 – Major
2 – Important
3 – Medium scale = EXFO DEPLOYMENT
5
A FEW SUCCESS STORIES
› TM - Malaysia
›FTTH test procedures and best practices
›Optimized process with contractors
FTTH overview
7
› +100M homes to connect by 2017
30M
10M
10
Basic PON architecture
EDFA
(Erbium Doped
Fiber Amplifier)
Video
1550 nm
Voice/Data Voice/Data/video Upstream
Downstream 1310 nm
1490nm/1310nm, 1550nm
1490 nm
OLT Optical
Couplers
ONT
(Optical (WDM) (Optical Network
Line Terminal)
Terminal) 1x32
Optical Or
Cascade
Splitter
IPTV
1-stage
splitter
RF
Connectors or splices
2-stage
splitter
FDT
Fiber Distribution Hub
FDT
FDH
Feeder Cable
© 2010 EXFO Inc. All rights reserved.. 15
PON Split ratio and typical loss
1x8 10.8
1x16 14.5
1x32 18
0.35dB/km 0.22dB/km
At 1310nm at 1550nm
© 2010 EXFO Inc. All rights reserved.. 16
FTTH PON—Active Equipment
17
FTTH PON - Passive Equipment
FDH Enclosures:
18
Special Connectors at Drops
Rugged cables for last portion from drop to ONT will require special
fiber optic adapters
Horizontal/
Garden style MDU
Vertical/Medium/
High rise MDU
20
New architecture trend: MDU’s – High density !
High/Medium-Rise MDU
Fiber Distribution Terminal
Fiber collector FDT
FDT
Riser Cable
Ribbon or multiple fiber
FDT
FDH
Feeder Cable
21
FTTH : The evolution
22
FTTH Next Gen PON
MDU
Cell Backhaul
Business
CO
splitter
splitter
SFU
splitter
23
FTTH Next Gen PON
NG- NG-PON2
PON1 WDM-PON
10G- 10G-
GPON EPON
Mass
Deployments
2016 2018-
2010 2012 2015
2020
24
FTTH Next Gen PON
Overlay new 10G/2.5G XG-PON1 system
CO Vid.Rx
2.5G-Rx New MUX
10G-Rx
10G-Tx
2.5G-Tx
NG-PON
OLT NG-PON User
New
MUX
Vid Tx MUX
Filter
G-PON
2G-Tx 1:N
OLT 1G-Rx
DOWN Existing G-PON User
UPSTREAM STREAM Legacy user
1550 nm Vid.Rx
1310 2G-Rx
nm 1490 nm 1G-Tx
1260 nm
1577 nm 25
FTTH Next Gen PON
Fiber distance 20 km 20 km
26
FTTH Next Gen PON
WDM-PON
Cell Backhaul MDU
λ1
CO AWG λ2 Business
Splitter
1:32
λ3
λ32 SFU
27
FTTH Next Gen PON
Items WDM-PON
Upstream speed Virtually no limits
E.g., 1 Gbit/s per user
Wavelengths T.B.C
E.g., DWDM in C-Band
28
FTTH Next Gen PON
Legacy Migration
ONT ONT
10G- ONT
GPON
ONT
GPON
10G-GPON
ONT ONT
GPON WDM
OLT ODN
OLT ODN
ONT
Use of the same optical 10G-
distribution networks (ODN)
ONT
EPON
to keep the investment 10G-EPON
29
OLT ODN
FTTH Network construction
Different requirements
High-
Efficient Simple
Performance
Avoid Be Reduce
Delays Future-proof truck-rolls
Important:
Measure ORL in the same direction as the
transmission of the 1550 nm video signal.
ORL is direction dependant
42
© 2010 EXFO Inc. All rights reserved. 42
Troubleshooting a live network
FiberFinder TM
No need to change heads, self-adjusts the
bending radius; No risk of creating
excessive loss and cut signal
Guaranteed IL below 1dB; Safe to use on
PON or high speed network
Self adjustment to fiber size and type (G652
& G657A)
43
© 2010 EXFO Inc. All rights reserved. 43
Here is why testing is required!
A real case study from a FTTH service provider in China
In one month, 600 000 home passed in a dense city area
46
cause of network
failures is contaminated
No. connectors
- NTT-Advanced Technology Research, 2010
© 2012
2010 EXFO Inc. All rights reserved.
reserved.. 48
48
Connector Issues
Dust/dirt residues transfer:
Did you know ?
If not cleaned properly:
Residues will transfer and may create permanent damage when mating
Before mating:
Connector A Connector B
After mating:
Connector A Connector B
Patch Panel 49
© 2010 EXFO Inc. All rights reserved. 49
Connector Cleaning
50
© 2010 EXFO Inc. All rights reserved. 50
Connector Cleaning
Dry method
An efficient technique for removing light contaminants
Often considered the technique of choice in a controlled manufacturing
environment where speed and ease of use are important factors
Advantages Disadvantages
Convenience of readily available tools Can possibly create electrostatic charges
Fast and easy Not effective in removing all contaminant types
51
© 2010 EXFO Inc. All rights reserved. 51
Connector Cleaning
Combination method (hybrid)
Combination cleaning is a mix of the wet and dry cleaning methods
The first step in hybrid cleaning is to clean the connector end-face with
a solvent and to dry any remaining residue with either a wipe or a swab
Advantages Disadvantages
Cleans all soil types
Reduces potential static field soil accumulation
Requires multiple
Automatically dries moisture and solvent used in the cleaning process
products
Captures soil in wiping material as an integrated aspect of cleaning procedure
Not expensive
54
© 2010 EXFO Inc. All rights reserved. 54
CERTIFY YOUR WORK
55
© 2010 EXFO Inc. All rights reserved. 55
NEXT GENERATION INSPECTION
Manual Automated
CONNECT CONNECT
CENTER CENTER
FOCUS FOCUS
CAPTURE CAPTURE
ANALYSE ANALYSE
100 %
AUTOMATED
© 2013 EXFO Inc. All rights reserved.. 56
THE MAX-FIP
Compact integrated and
dependable solution
Optical Plug ‘n Play Options › Integrated GUI with power
(VFL, Power meter) meter, VFL & inspection
› 11h Rechargeable battery
› Wi-Fi & Bluetooth
› 2GB built-in storage
Rubber
› Two USB ports
bumpers
Only 42mm in
thickness
Rugged focus
mechanism © 2013 EXFO Inc. All rights reserved.. 57
THE ONLY 100% AUTOMATED PROBE
50%
Show time!
© 2013 EXFO Inc. All rights reserved.. 58
Design
OTDR Testing
59
Simplified OTDR
Inactive !
OLT
Event
End of Fiber
Reflection Fresnel
Backscatter
line
Noise
Launch
Relative
Power
OTDRs deal with multiple parameters that all interact with each other
OTDRs are a matter of trade-offs : gain this, loose that.
There are multiple recipies to get a good OTDR trace, as well as a bad
one!
Connector End-Face
By the time the primary pulse reaches the end of a relatively long optical
fiber, most of its energy has been dissipated.
The OTDR records the results of the first pulse then launches another
and then another. It ‘averages’ the results of multiple pulse launches to
give the operator a clean trace
The more averaging time, the more dynamic range
Pulse width is the parameter that has the greatest impact on OTDR
performance. In fact, adjusting PW will impact both dynamic range and
resolution in very predictable ways.
Put simply, the longer the LASER stays on the more energy is injected
into the fiber and the greater the effective range.
Counter side is the resolution of the pulse is reduced and increases the
dead zones
Short pulses will give a better resolution but less dynamic range:
Connectors
are
measured 5ns pulse
for distance
and marked
as separate
events
Long pulses will give a better dynamic range but less resolution:
Connectors
are
« merged »
30ns pulse
and
identified as
one event
1.5 dB
It is the distance between:
-2.00
-8.00
-10.00
Event Dead Zone
-8.00
0.5 dB
-10.00
Attenuation Dead Zone
PON-optimized OTDR:
Getting Repeating
wrong the same
OTDR job three
traces times
THE PAINS
Countless Complex
trace instrument
analyses for training/
managers support
Traditional OTDR
© 2010 EXFO Inc. All rights reserved.. 77
And can you read this?
Intelligent OTDR
© 2010 EXFO Inc. All rights reserved.. 78
QUESTIONS FOR FTTH DEPLOYMENTS
Start
In the
What you see!
background
Power (dB)
Distance (m)
F2
OLT
F1 No transmission
ONT F2 F1
OLT
› OTDR-based
› PON/FTTH or P2P
(DATA TESTING)
› Connectivity test
› Throughput measurement
› Response time, download and upload times
Ethernet
› Measure VoIP metrics: MOS, RTP, Latency
DATA
xDSL
(VIDEO TESTING)
Emulate set top box Set Top Box
88
© 2010 EXFO Inc. All rights reserved. 88
Pruebas en FTTH: Conclusión
90
© 2013 EXFO Inc. All rights reserved. 90
Post-processing and reporting
FastReporter 2
› Compatible Bellcore v1 et v2
› And more … 92
© 2010 EXFO Inc. All rights reserved. 92
Data Post-Processing FastReporter 2
REDUCE OPEX
THE CONNECTED EXPERIENCE
› Better Methods and Procedures
› Better Asset Control
› Better “Business Intelligence”
94
© 2013 EXFO Inc. All rights reserved. 94
Thank you
Jimmy.gagnon@exfo.com