LV CIRCUIT BREAKERS CATALOG AND

PRICE LIST 2022


12
Molded Case Circuit Breakers & Earth Leakage Circuit Breakers
Molded Case Circuit Breakers & Earth Leakage Circuit Breakers
Product Price List

13
3
Molded Case Circuit Breakers & Earth Leakage Circuit Breakers
Product Price List

Molded Case Circuit Breaker

Molded Case Circuit Breakers & Earth Leakage Circuit Breakers


MCCB 2 Pole

Price (THB) Dimension


Ampere kA
Model Rated current (A) (mm)
Frame 240VAC /415VAC
Adjustable WxHxD

HGM100E 20,25,32,40,50,63,75,80,100 35 / 16 1,800


100 50 x 130 x 68
HGM100S 20,25,32,40,50,63,75,80,100 50 / 20 2,500
250 HGM250E 125,160,200,250 50 / 20 5,000 105 x 165 x 68

MCCB 3 Pole

Price (THB)
Ampere kA Dimension (mm)
Model Rated current (A)
Frame 415VAC WxHxD
Adjustable

HGM100E 20,25,32,40,50,63,75,80,100 16 2,300


100 75 x 130 x 68
HGM100H 20,25,32,40,50,63,75,80,100 26 2,600
HGM125H 20,25,32,40,50,63,75,80,100,125 38 3,600
125 90 x 155 x 68
HGM125L 20,25,32,40,50,63,75,80,100,125 55 4,500
HGM250S 125,160,200,250 26 4,800
250 HGM250H 125,160,200,250 38 5,500 105 x 165 x 68

HGM250L 125,160,200,250 55 6,000


HGM400E 300,400 45 13,000
400 140 x 257 x 110
HGM400S 300,400 65 15,000
HGM630E 500,630 45 20,000
630 210 x 280 x 110
HGM630S 500,630 65 25,000
800 HGM800S 700,800 65 32,000 210 x 280 x 110

1000 UCB1000S** 505-1000 100 80,000 210 x 370 x 110

1250 UCB1250S** 630-1250 100 90,000 210 x 370 x 110

1600 UCB1600S ** 640-1600 65 110,000 210 x 371 x 151

** Electronic Type

- สำาหรับราคา Electronic Type รุน่ 400AF - 800AF โปรดติดต่อตัวแทนจำาหน่าย


- อุปกรณ์เสริมมาตรฐาน : แผ่่นกัน
้ เฟสมีให้ สำาหรับเบรกเกอร์ทุกรุ่น

4
อุปกรณ์เสริม
Molded Case Circuit Breakers & Earth Leakage Circuit Breakers

Accessories

HGM Type Molded Case Circuit Breakers


1. Plug in Devices 7. Lug Terminal 13. Auxiliary Switch
2. Terminal Cover for Plug-In Type 8. Terminal Cover 14. Trip Alarm Switch
3. Busbar 9. Padlock for Rotary Handle 15. Motor Operator
4. Insulation Barrier 10. Rear Connection Terminal 16. Direct Rotary Handle
5. DIN Rail Adaptor 11. Shunt Trip Coil 17. Extended Rotary Handle
6. Mechanical Interlock 12. Undervoltage Trip Coil

Hyundai List
Accessories For Molded Case Circuit Breaker (MCCB) Code
Price (THB)
Auxiliary 1Contact for HGM100
AUX 10GM C1 500
,HGM125,HGM250

Auxiliary
Auxiliary 2Contact for HGM100, HGM125, HGM250 AUX 10GM C2 750
switch
Auxiliary 1Contact for HGM400, HGM630, HGM800 AUX 40GM C1 850
Auxiliary 3Contact right-hand-side
AUX 120GMSC1 2,000
for HGM1000S, HGM1250S
Alarm Switch 1Contact left-hand-side for
ALT 10GM L1 600
HGM100,HGM125,HGM250
Alarm Switch 1Contact right-hand-side
ALT 10GM R1 500
for HGM100,HGM125,HGM250
Alarm switch
Alarm Switch 1Contact left-hand-side
ALT 40GM L1 750
for HGM400,HGM630,HGM800
Alarm Switch 1Contact right-hand-side
ALT 120GMS 1,100
for HGM1000S, HGM1250S

5
Product Price List

Molded Case Circuit Breakers & Earth Leakage Circuit Breakers


Accessories For Molded Case Circuit Breaker (MCCB) Code Price (THB)

Shunt Trip AC200-250V for HGM100,HGM125,


SHT 10GM AC200-250V 900
HGM250

Shunt Trip Shunt Trip AC200-230V for HGM400,HGM630


SHT 40GM AC200-230V 2,000
,HGM800

Shunt Trip AC200-230V for HGM1000S,1250S SHT120GMS 2,500


Under Voltage Trip AC200-250V for HGM100,
UVT 10GM AC200-250V 3,000
HGM125,HGM250
Under Voltage Under Voltage Trip AC200-230V for HGM400
UVT 40GM AC200-230V 3,500
Trip ,HGM630,HGM800
Under Voltage Trip AC200-230V
UVT 120GMS 3,800
for HGM1000S,1250S

Extended Rotary Handle for HGM100 TFH 10GM 2,500

Extended Rotary Handle for HGM125 TFH 12GM 2,500


Extended Rotary
Extended Rotary Handle for HGM250 TFH 25GM 2,500
Handle
Extended Rotary Handle for HGM400 TFH 40GM 5,000

Extended Rotary Handle for HGM630,HGM800 TFH 80GM 5,000

Direct Rotary Handle for HGM100 TFG 10GM U 1,500

Direct Rotary Handle for HGM125 TFG 12GM U 1,500


Direct Rotary
Direct Rotary Handle for HGM250 TFG 25GM U 1,500
Handle
Direct Rotary Handle for HGM400 TFG 40GM U 4,000

Direct Rotary Handle for HGM630,HGM800 TFG 80GM U 4,000

Motor Operator AC/DC240V for HGM100 MOT 10GM 20,000

Motor Operator AC/DC240V for HGM125 MOT 12GM 20,000

Motor Operator AC/DC240V for HGM250 MOT 25GM 20,000


Motor Operator
Motor Operator AC/DC240V for HGM400 MOT 40GM 25,000

Motor Operator AC/DC240V for HGM630,HGM800 MOT 80GM 30,000


Motor Operator AC/DC240V
MOT 120GMS3 80,000
for HGM1000S,1250S

Pad Lock for HGM100,HGM125,HGM250 PLD 10 GM 700

Pad Lock Pad Lock for HGM400,HGM630,HGM800 PLD 40 GM 700

6
คิดค้นมาเพื่ อมอเตอร์ในงานอุตสาหกรรม
เพื่ อยืดอายุการใช้งาน และประสิทธิภาพของฉนวนที่ดี

- ขนาดเฟรมครอบคลุมตั้งแต่ 9 - 800A (8 เฟรม)


- พิ กัดของแรงดันฉนวน 1000V (ขนาดตั้งแต่ 50A ขึ้นไป)
- ใช้พื้นที่การติดตั้งที่น้อยกว่าด้วย Auxiliary Contact ชนิดติดตั้งด้านหน้า
- Thermal Overload Relay สามารถเชอมต่อเข้าโดยตรงกับ Magnetic Contactor
โดยไม่ต้องใช้สาย
- Auxiliary Relay สามารถลดค่า Power Consumption
- เพิ่ มความปลอดภัยด้วยฝาครอบ Thermal Overload
- สามารถใช้ได้ทั้งแรงดัน AC/DC (ขนาดตั้งแต่ 115A ขึ้นไป)
- มาตรฐานและการรับรอง : KERI CB, Marine Approvals (7’s Classifications)
9
Magnetic contactors & Overload Relays
Product Price List

Magnetic contactors & Overload Relays


Magnetic Contactor

Dimension
Rated Capacity พิ กัดมอเตอร์ PRICE
Model Auxiliary (mm)
AC3(kW/A) kW@400V (THB)
WxHxD
HGC 9B 9 4 550

HGC 12B 12 5.5 1NO 45 x 75 x 86 700

HGC 18B 18 7.5 850

HGC 25 25 11 1NO+1NC 45 x 99.6 x 96.6 1,000

HGC 32 32 15 1,250
2NO+2NC 45 x 99.6 x 96.6
HGC 40 40 18.5 1,600

HGC 50 50 22 2,500
2NO+2NC 55 x 123.6 x 129.1
HGC 65 65 30 3,000

HGC 75 75 37 3,500

HGC 85 85 45 2NO+2NC 70 x 146 x 153 4,000

HGC 100 100 55 5,000

HGC 115 115 60 6,500

HGC 130 130 65 2NO+2NC 103 x 155 x 145.1 7,000

HGC 150 150 75 10,000

HGC 185 185 90 12,000

HGC 225 225 132 2NO+2NC 138 x 204 x 174.2 15,000

HGC 265 265 147 20,000

HGC 300 300 160 22,000

HGC 400 400 220 2NO+2NC 163 x 243 x 203 28,000

HGC500 500 250 35,000

HGC630 630 330 45,000


2NO+2NC 276 x 314 x 255.3
HGC800 800 440 60,000

10
Magnetic contactors & Overload Relays

Thermal Overload Relay


ช่วงปรับตั้งกระแส Applicable Dimension (mm) PRICE
Model
Over load (Amp) Contactor WxHxD (THB)
HGT18KB A0P26S 0.18-0.26

HGT18KB A0P35S 0.25-0.35

HGT18KB A0P50S 0.34-0.50

HGT18KB A0P70S 0.5-0.7

HGT18KB A0P90S 0.6-0.9

HGT18KB A1P20S 0.8-1.2

HGT18KB A1P60S 1.1-1.6

HGT18KB A2P10S 1.5-2.1 HGC9B


HGC12B 45 x 78.2 x 82.7 800
HGT18KB A0003S 2~3 HGC18B

HGT18KB A4P20S 2.8-4.2

HGT18KB A0005S 3~5

HGT18KB A0006S 4~6

HGT18KB A0008S 5.6~8

HGT18KB A0009S 6~9

HGT18KB A0012S 8~12

HGT18KB A0018S 12~18

11
Product Price List
ช่วงปรับตั้งกระแส Applicable Dimension (mm) PRICE
Model
Over load (Amp) Contactor WxHxD (THB)

Magnetic contactors & Overload Relays


HGT40K A0012S 8~12

HGT40K A0018S 12~18


HGC25
HGT40K A0022S 15-22 HGC32 45 x 69.4 x 95.5 900
HGC40
HGT40K A0025S 17-25

HGT40K A0032S 22-32

HGT65K A0040S 28-40


HGC50
HGT65K A0050S 34-50 55 x 89.3 x 110.7 1,100
HGC65
HGT65K A0065S 45-65

HGT100K A0085S 59-85


HGC75, HGC85,
70 x 105 x 128.1 1,700
HGC100
HGT100K A0100S 70-100

HGT150K A0130S 78-130


HGC115 , HGC130,
180 x 159 x 179.3 4,500
HGC150
HGT150K A0150S 90-150

HGT265K A0225S 135-225


HGC185 , HGC225,
180 x 185 x 179.3 6,000
HGC265
HGT265K A0265S 159-265

HGT500K A0400S 240-400 HGC300,400,500 180 x 205.2 x 179.3 12,000

HGT800K A0630S 378-630


HGC630 , HGC800 245 x 197 x 209.9 15,000
HGT800K A0800S 480-800

12
Magnetic contactors & Overload Relays

Accessories

9 - 100 AF
1. Auxiliary Contact Block 4. Timer HGC ET 7. Thermal Overload Relay HGT
(Front Side) HGC TB 2
2. Auxiliary Contact Block 5. Interlock Unit HGC IU 8. Separate Mounting Base HGTMB
(Left/Right Side) HGC SB 3
3. Mechanical Latching Block 6. Surge Absorber HGC RC/CD 9. Front Satety Cover HGCFC 100
HGC LB 100

13
Product Price List

Auxiliary Contact Block

Magnetic contactors & Overload Relays


Auxiliary Applicable Mounting Price
Item Model Code
contact product position (THB)
HGC TB02 HGC TB02NS 0NO+2NC 200

HGC TB11 HGC TB11NS 1NO+1NC 200

HGC TB20 HGC TB20NS 2NO+0NC 200

HGC TB04 HGC TB04NS 0NO+4NC HGC9-18B 500


HGC9-100
HGC TB13 HGC TB13NS 1NO+3NC HGR 500

HGC TB22 HGC TB22NS 2NO+2NC 500

HGC TB31 HGC TB31NS 3NO+1NC 500

HGC TB40 HGC TB40NS 4NO+0NC FRONT 500


HGC SB40 HGC9-18B
HGC SB40 1NO+1NC 400
11NS HGC9-40
HGC SB100
HGC SB100 1NO+1NC HGC50-100 400
11NS
HGC SB800
HGC SB800 1NO+1NC HGC115-800 500
11NS SIDE

Front Auxiliary Contacts Side Auxiliary Contacts

Maximum combination of b auxiliary contacts is 4NC. Maximum combination of b auxiliary contacts is 4NC.

Electronic Timer
Operation Applicable Price
Item Model Wiring Diagram
Voltage product (THB)
AC/DC
HGC ET1 1,500
90-240
HGC9-100 HGR
HGC ET2 AC/DC 24-60 1,500

Operation Concept Map

14
Capacitor Switching Contactor
Magnetic contactors & Overload Relays

Making & Breaking Frequency and Lifetime

Making & Breaking Frequency 240 Cycles/h

Ue ≤ 440 Vac 250,000


Electrical Lifetime
(AC-6b)
500 Vac ≤ Ue ≤ 690 Vac 100,000

HGC คอนแทคเตอร์สำาหรับคาปาซิเตอร์ ถูกออกแบบตามมาตรฐาน IEC 60947-1 และแก้ปัญหาการ Switching Power


ของคาปาซิเตอร์ในโรงงาน

Power in kvar
(at ambient temperature 55℃) Price
Model
(THB)
400/415V 440V 500/550V 690V
HGC 9C 9.7 9.7 14 14 1,800

HGC 12C 12 12 15 15 2,000

HGC 18C 16.7 16.7 24 24 2,200

HGC 25C 20 20 26 26 2,400

HGC 32C 25 25 30 30 2,500

HGC 40C 29 29 35 35 3,300

HGC 50C 40 40 45 45 3,800

HGC 65C 43.5 43.5 54 54 4,400

HGC 75C 52 52 60 60 4,800

HGC 85C 56 56 70 70 5,500

HGC 100C 62 62 80 80 6,500

˙ Capacitor switching contactor is combined with magnetic contactor


˙ Contactor is assembled with damping resistors which limit the high in-rush current when the
capacitors are switched on. They are assembled with early-make contact block, which is switched on
before the main contacts, thus, limiting the in-rush current.
˙ Capacitor switching unit is composed of 3 NO main contacts and 1 auxilliary contact (1NO or 1NC).
˙ When power is supplied, capacitor creates oscillation frequency (1~15KHZ) and generates transient
current (over 180 ln). Capacitor switching unit limits the transient current, thus, protects main contacts.
˙ When power is supplied to magnetic contactor, the value of maximum current is reduced as following
cases.
- Inductance of main power supply is too high.
- Rating of line transformer is too low.
- Short circuit of transformer is too high.

15
Product Price List

Control Relay (HGR)

Magnetic contactors & Overload Relays


• HYUNDAI control relay is the best solution where quick response
time is required such as in control circuit and factory automation.
• HGR-N is for AC operation, and HGR-P is for DC operation.
• Both HGR-N and HGR-P have five contact arrangements; 4NC,
1NO+3NC, 2NO+2NC, 3NO+1NC,4NO.
• The protection degree is IP20.
• Accessories can be attached by one-touch method.
- Auxiliary contact block - Electronic timer - Latching block
- Surge absorber HGR-N (AC) HGR-P (DC)
• Maximum NC contact 4NC is the maximum contact combination of
control relay including auxiliary contact block. Front mounting auxiliary contact block (HGC TB) can be
attached on control relay; however, side mounting auxiliary contact block (HGC SB) is not applicable.

Operation Auxiliary Contact


Item Model Code Price (THB)
Voltage (V)
NO NC

HGR-N04 HGR 04NS X220 - 4NC 930


HGR-N13 HGR 13NS X220 1NO 3NC 930
AC220V,
HGR-N22 HGR 22NS X220 50Hz 2NO 2NC 930
HGR-N31 HGR 31NS X220 3NO 1NC 930
HGR-N40 HGR 40NS X220 4NO - 930
HGR-P04 HGR 04PS D110 - 4NC 1,500
HGR-P13 HGR 13P S D110 DC110V 1NO 3NC 1,500
Permanent
HGR-P22 HGR 22P S D110 2NO 2NC 1,500
Magnetic
HGR-P31 HGR 31P S D110 3NO 1NC 1,500
HGR-P40 HGR 40P S D110 4NO - 1,500

Note : Operating voltage


AC 24V,48V,100V,110V,220V,240V,380V 50Hz,
DC 24V,48V,100V,125V Non-specified voltage can be available on request.

Accessories
˙HGR has DC and AC types, and 5 types of possible
contact configurations.
˙HGR follows IEC 60947 and protection degree is IP20.
˙Usable temperature range is -25 - 40°C
˙HGR which has fast response time is appropiate for
application of control circuit and factory automation.
˙Applicable standard IEC 60947-5-1, VDE0660, CENELEC-EN50011

Control Coil
Operational Applicable Operational Applicable
Product Order Code Price (THB) Product Order Code Price (THB)
Voltage Product Voltage Product

V HGCOL18X220 HGC9 - 18 280 V HGCOL150F220 HGC115 - 150 2,200

220 HGCOL40X220 HGC25 - 40 410 Norminal


AC100~240 HGCOL265F220 HGC185 - 265 3,300
Frequency
Voltage
AC 50 Hz
HGCOL65X220 HGC50 - 65 550 220 DC100~220 HGCOL500F220 HGC630 - 800 5,200

AC200~240
HGC OL100X220 HGC75 - 100 820 HGCOL800F220 HGC300 - 500 6,700
DC200~220

16
Application for DOL Starting
Magnetic contactors & Overload Relays

Contactor and Thermal Overload Relay for Normal DOL Starter


Motor Output Direct On Line (DOL)
Contactor Price Price Total
KW HP FLC (A) Overload Relay
(MC) (THB) (THB) (THB)
0.06 1/12 0.22 HGC 9B-10 550 HGT18KB 0.22A (0.18-0.26) 800 1,350

0.09 1/8 0.33 HGC 9B-10 550 HGT18KB 0.33A (0.25-0.35) 800 1,350

0.12 1/6 0.42 HGC 9B-10 550 HGT18KB 0.42A (0.34-0.50) 800 1,350

0.18 1/4 0.64 HGC 9B-10 550 HGT18KB 0.64A (0.50-0.70) 800 1,350

0.25 1/3 0.88 HGC 9B-10 550 HGT18KB 0.88A (0.60-0.90) 800 1,350

0.37 1/2 1.22 HGC 9B-10 550 HGT18KB 1.22A (1.1-1.6) 800 1,350

0.55 3/4 1.5 HGC 9B-10 550 HGT18KB 1.5A (1.1-1.6) 800 1,350

0.75 1 2 HGC 9B-10 550 HGT18KB 2A (1.5-2.1) 800 1,350

1.1 1.5 2.6 HGC 9B-10 550 HGT18KB 2.6A (2-3) 800 1,350

1.5 2 3.5 HGC 9B-10 550 HGT18KB 3.5A (2.8-4.2) 800 1,350

2.2 3 5 HGC 9B-10 550 HGT18KB 5A (4-6) 800 1,350

2.5 3.4 5.7 HGC 9B-10 550 HGT18KB 5.7A (5.6-8) 800 1,350

3.0 4 6.6 HGC 9B-10 550 HGT18KB 6.6A (5.6-8) 800 1,350

3.7 5 8.2 HGC 9B-10 550 HGT18KB 8.2A (6-9) 800 1,350

4.0 5.5 8.5 HGC 9B-10 550 HGT18KB 8.5A (8-12) 800 1,350

5.0 6.8 10.5 HGC 12B-10 700 HGT18KB 10.5A (8-12) 800 1,500

5.5 7.5 11.5 HGC 12B-10 700 HGT18KB 11.5A (8-12) 800 1,500

7.5 10 15.5 HGC 18B-10 850 HGT18KB 15.5A (12-18) 800 1,650

8.0 11 16.7 HGC 18B-10 850 HGT18KB 16.7A (12-18) 800 1,650

11.0 15 22 HGC 25-11 1,000 HGT40K 22A (17-25) 900 1,900

12.5 17 25 HGC 25-11 1,000 HGT40K 25A (22-32) 900 1,900

15.0 20 30 HGC 32-22 1,250 HGT40K 30A (22-32) 900 2,150

18.5 25 37 HGC 40-22 1,600 HGT65K 37A (28-40) 1,100 2,700

Main Circuit Diagram

17
Product Price List

Application for Y-D Starting

Magnetic contactors & Overload Relays


Motor Output Star-Delta (Y-D)
Main Delta Star Elec-
FLC Total
KW HP Contactor Contactor Contactor Thermal O/L tronic
(A) (THB)
(KM) (KD) (KY) Time
4.0 5.5 8.5 HGC 9B-11 HGC 9B-11 HGC 9B-11 HGT18KB 4.9A (4-6) N/A 3,050

5.0 6.8 10.5 HGC 9B-11 HGC 9B-11 HGC 9B-11 HGT18KB 6A (5.6-8) N/A 3,050
HGT18KB 6.6A
5.5 7.5 11.5 HGC 12B-11 HGC 12B-11 HGC 9B-11 N/A 3,350
(5.6-8)

7.5 10 15.5 HGC 12B-11 HGC 12B-11 HGC 9B-11 HGT18KB 9A (8-12) N/A 3,350
HGT18KB 9.6A
8.0 11 16.7 HGC 12B-11 HGC 12B-11 HGC 9B-11 N/A 3,350
(8-12)
HGT18KB
11.0 15 22 HGC 18B-11 HGC 18B-11 HGC 12B-11 N/A 3,800
12.7A (12-18)
HGT18KB
12.5 17 25 HGC 18B-11 HGC 18B-11 HGC 12B-11 N/A 3,800
14.5A (12-18)
HGT18KB
15.0 20 30 HGC 18B-11 HGC 18B-11 HGC 12B-11 N/A 3,800
17.4A (12-18)
HGT40K 21.4A
18.5 25 37 HGC 25-11 HGC 25-11 HGC 18B-11 N/A 3,950
(17-25)
HGT40K 23.2A
20 27 40 HGC 25-11 HGC 25-11 HGC 18B-11 N/A 3,950
(22-32)
HGT40K 25.5A
22 30 44 HGC 32-22 HGC 32-22 HGC 18B-11 N/A 4,450
(22-32)
HGT40K 29A (22-
25 34 50 HGC 32-22 HGC 32-22 HGC 18B-11 N/A 4,450
32)
HGT40K 34.8A
30 40 60 HGC 40-22 HGC 40-22 HGC 25-11 N/A 5,100
(28-40)
HGT65K 41.7A
37 50 72 HGC 50-22 HGC 50-22 HGC 25-11 N/A 7,100
(34-50)
HGT65K 45.8A
40 54 79 HGC 50-22 HGC 50-22 HGC 32-22 N/A 7,350
(34-50)
HGT65K 49.3A
45 60 85 HGC 50-22 HGC 50-22 HGC 32-22 N/A 7,350
(45-65)
HGT65K 60.9A
55 75 105 HGC 65-22 HGC 65-22 HGC 40-22 N/A 8,700
(45-65)
HGT100K 69.6A
60 81 120 HGC 75-22 HGC 75-22 HGC 40-22 N/A 10,300
(59-85)

Motor starting condition:


* Six times the full load current : within 10sec.
- Motor full load current : Indicate the full load current for standard
type.
-”The motor having the largest output” Includes motor simultaneously
being started with this motor.

18
Motor Output Star-Delta (Y-D)
Magnetic contactors & Overload Relays

Main Delta Star Elec-


FLC Total
KW HP Contactor Contactor Contactor Thermal O/L tronic
(A) (THB)
(KM) (KD) (KY) Time
HGT100K 75.4A
65 87 130 HGC 75-22 HGC 75-22 HGC 50-22 N/A 11,200
(59-85)
HGT100K 81.2A
75 100 140 HGC 85-22 HGC 85-22 HGC 50-22 N/A 12,200
(70-100)
HGT100K 98.6A
90 125 170 HGC 100-22 HGC 100-22 HGC 65-22 N/A 14,700
(70-100)
HGT150K 118.9A
110 150 205 HGC 130-22 HGC 130-22 HGC 75-22 N/A 22,000
(78-130)
HGT150K 142.1A
132 180 245 HGC 150-22 HGC 150-22 HGC 85-22 N/A 28,500
(90-150)
HGT150K 150.8A
140 190 260 HGC 150-22 HGC 150-22 HGC 100-22 N/A 28,800
(90-150)
HGT265K 171.1A
160 220 295 HGC 185-22 HGC 185-22 HGC 100-22 N/A 34,500
(135-225)
HGT265K 197.2A
184 250 340 HGC 225-22 HGC 225-22 HGC 115-22 N/A 42,500
(135-225)
HGT265K 214.6A
200 270 370 HGC 225-22 HGC 225-22 HGC 130-22 N/A 43,000
(135-225)
HGT265K 236.6A
220 300 408 HGC 265-22 HGC 265-22 HGC 150-22 N/A 55,500
(159-265)
HGT500K 266.8A
250 340 460 HGC 300-22 HGC 300-22 HGC 185-22 N/A 68,000
(240-400)
HGT500K 275.5A
257 350 475 HGC 300-22 HGC 300-22 HGC 185-22 N/A 68,000
(240-400)
HGT500K 316.7A
295 400 546 HGC 400-22 HGC 400-22 HGC 185-22 N/A 80,000
(240-400)
HGT500K 336.5A
315 430 580 HGC 400-22 HGC 400-22 HGC 225-22 N/A 83,000
(240-400)
HGT500K 368.9A
355 480 636 HGC 400-22 HGC 400-22 HGC 225-22 N/A 83,000
(240-400)
HGT800K 411.8A
400 545 710 HGC 630-22 HGC 630-22 HGC 265-22 N/A 124,000
(378-630)
HGT800K 454.5A
440 545 780 HGC 630-22 HGC 630-22 HGC 265-22 N/A 124,000
(378-630)
HGT800K 516.2A
500 680 890 HGC 630-22 HGC 630-22 HGC 300-22 N/A 126,000
(378-630)
HGT800K 696A
670 910 1200 HGC 800-22 HGC 800-22 HGC 400-22 N/A 162,000
(480-800)

19
Product Price List

Magnetic contactors & Overload Relays


External Structure and Contents of Nameplate
Magnetic Contactors

1 11 12

8
2

9
3

5 6

6 10

Type Name
1. Control Power Terminal
2.1 Control
Main Terminal
Power Terminal
3.2 Main
Auxiliary Terminal
Terminal
Ratings
4.3 Auxiliary
Type NameTerminal
5.4 Type
Manufacturer
Name Name
6.5 Manufacturer
Safety CoverName Standards
KC Mark and
7.6 Safety
Din-Rail Mounting Part
Cover Number
8.7 Upper Frame
Din-Rail Mounting Part
9. Upper Cover
8 Upper Frame
10. Name Plate
9 Upper Cover
11. Screw Mounting Hole UL Rating
10 Name Plate
12. Mounting Hole for
11 Screw Mounting Hole
Auxiliary Devices on Sides
12 Mounting Hole for Country of Origin
Auxiliary Devices on Sides Serial No.
HHI Logo Manufacturer

20
HGN, HGS
Air Circuit Breaker

Air Circuit Breakers


Applicable to Various Location

21
Magnetic
Air Circuitcontactors
Breaker & Overload Relays
Product Price List

HGN , HGS
Air Circuit Breakers

22
Overview
Air Circuit Breaker

Product Type

Capable of Responding to Various Customer Applications


ACB รุ่น HG Series
มาพร้อมกับพิ กัดการตัดกระแสลัดวงจรที่สูงขึ้นและฟังก์ชั่นการทำางานที่มีประสิทธิภาพของOCR
จึงทำาให้เข้าถึงกลุ่มลูกค้าได้หลากหลาย อาทิ เช่น กลุ่มอาคาร, โรงงานอุตสาหกรรม, ศูนย์คอมพิ วเตอร์ และอื่นๆ
ทุกรุ่นถูกออกแบบมาให้มีพิกัดกระแสไหลผ่่าน N phase 100%

Building Computer Center Industrial Facility Power Utility

- Multipurpose Building - Broadcasting Station - Steelworks - Power Plant


- Great Hospital - Information/ - Petrochemisty - Substation
- Commercial Building Computer Center - Paper - mill - Micro Grid
- Hotel - ESS

Acquired Standards and Certifications / ได้รับมาตรฐานและการรับรอง


• KS Certification : KS C 4620
• CB Certification (DEKRA, KERI) : IEC 60947-1, 2
• CE Mark
• CCC Certification
• Vessel Certification : LR, ABS, KR, BV, DNV・GL,
NK, RINA, RS

23
Product Price List

Air Circuit Breaker


Product Features
Hyundai ACB รุ่น HG Series
ถูกพั ฒนาให้มี อุปกรณ์เสริมที่หลากหลายและทันสมัยมากขึ้นด้วย protection relay ที่เป็นระบบดิจิตอล
เพื่ อเพิ่ มทางเลือกและความพึ งพอใจให้กับลูกค้าอีกทั้งยังมีขนาดที่กระทัดรัด

Type per Rating / ชนิดของเฟรมต่างๆ


• HGN
Frame 4 Type
- 2,000/4,000/5,000/6,300 A
• HGS
Frame 2 Type
- 1,600/3,200 A

Outstanding Breaking Capacity

- พิ กัดกระแสลัดวงจรสูงสุด : 150 kA ( ที่ 500 V , HGN


D Frame)
- พิ กัดแรงดันอิมพั ลส์ : 12 kV

Muiti Busbar

- บัสบาร์เทอร์มินอล สามารถเปลี่ยนเป็นแบบ Horizontal/


Vertical

Costomized Retrofit ACB can be Provided

ACB รุ่น HG series ถูกผ่ลิตและพั ฒนาให้สามารถเข้ากันได้


กับ ACB ทุกยี่ห้อ โดยที่ cradle, Phase, Pole และ
Terminal ของ ACB สามารถผ่ลิตไว้ได้เหมือนของเดิมที่ติด
ตั้งไว้ก่อนหน้านี้

Accurate Accident Detection

รายงานผ่ลความผ่ิดปกติผ่่านทางสมาร์ทโฟนโดยใช้แอพ NFC
android (สามารถบันทึกข้อมูลได้สูงสุด 10 ครั้ง)

24
Air Circuit Breaker
Air Circuit Breaker

HG Series
Standard IEC 60947-2
Rated Current 630A ~ 6300A
Rated Breaking Capacity[Icu] 85kA ~ 150kA at AC 500/480/460/415/380/220V
Ics = 100% Icu
Enhanced protection by high functional protection relay with LED
Reliable quality type tested by KEMA and KERI
Multi Bus Bar : Bus Bar Terminal can be changed to horizontal/vertical

Model HGS 08A HGS 10A HGS 12A HGS 16A


Rated current (A) 800 1000 1250 1600

Number of pole 3 Poles and 4 Poles(Option)

Rated insulation voltage (Ui) (V) AC1,000

Rated operation voltage (Ue) (V) AC690

Rated frequency (Hz) 50Hz

AC690/600/550V 50 50 50 50
Rated breaking
capacity [Icu, Ics] AC500/480/460V 65 65 65 65
(kA sym)
AC415/380/220V 65 65 65 65

3P Fixed type 337 x 404 x 296


Dimensions
(W x H x D, mm)
3P Draw out type 328 x 460 x 368

Unit price (3Poles Fixed type)

GPR-LA (LTD/STD/INST/GFT/PTA
90,000 95,000 100,000 110,000
Fault indication LED

Unit price (3Poles Draw-out type)

GPR-LA (LTD/STD/INST/GFT/PTA
112,000 115,000 128,000 140,000
Fault indication LED

Accessories (Option)

Charging Motor (HGNS M2U) 15,000

Shunt trip (HGNS S2) 4,000

Closing coil (HGNS C2) 4,000

Undervoltage with time delay controller + UVT coil


10,000
(HGNS V2)

Key lock for open position (HGNS AB) 2,500

External Neutral Current Transformer 7,500

Accessories (Standard) Standard Protection Relay


- Auxiliary Contact (HGS: 3NO+3NC, HGN: 5NO+5NC) - LED Protection LTD/STD/INST/GFT
- Spring Charging Switch - Self Power
- Counter - Fail Safe
- Door Flange - Communication (Mod BUS)
- Contact Alarm LTD/STD/INST/GFT
- 256 Fault Recording
Remark : Please contact us for the price of ACB 4P
25
Product Price List

Air Circuit Breaker


Model HGS 20B HGS 25B HGN 32B HGN 40B HGN 50C HGN 63D
Rated current (A) 2000 2500 3200 4000 5000 6300

Number of pole 3 Poles and 4 Poles(Option)

Rated insulation voltage (Ui) (V) AC1,000

Rated operation voltage (Ue) (V) AC690

Rated frequency (Hz) 50Hz

AC690/600/550V 70 70 85 85 85 100
Rated breaking
capacity [Icu, Ics] AC500/480/460V 85 85 100 100 100 120
(kA sym)
AC415/380/220V 85 85 100 100 100 120

3P Fixed type 408 x 404 x 296 633 x 400 x 296 775 x 404 x 296
Dimensions
(W x H x D, mm)
3P Draw out type 399 x 460 x 368 624 x 460 x 368 766 x 460 x 368

Unit price (3Poles Fixed type)

GPR-LA (LTD/STD/INST/GFT/PTA
125,000 150,000 180,000 250,000 450,000 650,000
Fault indication LED

Unit price (3Poles Draw-out type)

GPR-LA (LTD/STD/INST/GFT/PTA
155,000 190,000 225,000 320,000 550,000 750,000
Fault indication LED

Option Accessories

Charging Motor (HGNS M2U) 15,000

Shunt trip (HGNS S2) 4,000

Closing coil (HGNS C2) 4,000

Undervoltage with time delay


10,000
controller + UVT coil (HGNS V2)
Key lock for open position
2,500
(HGNS AB)

External Neutral Current Transformer 20,000 25,000 N/A

Accessories (Standard) Standard Protection Relay


- Auxiliary Contact (HGS: 3NO+3NC, HGN: 5NO+5NC) - LED Protection LTD/STD/INST/GFT
- Spring Charging Switch - Self Power
- Counter - Fail Safe
- Door Flange - Communication (Mod BUS)
- Contact Alarm LTD/STD/INST/GFT
- 256 Fault Recording
Remark : Please contact us for the price of ACB 4P ** 63000AF Replace to 4P for GFT
26
Technical Data
Air Circuit Breaker

Various Accessories (Main Unit)

27
Product Price List

Air Circuit Breaker


Various Accessories (Main Unit)

28
HRC Moular Devices

HG Modular Devices
HGD / HRC / HRO

29
Product Price List

HRC Moular Devices


HGD63M, 63 AF, 6 kA

Standard IEC/EN 60898-1


Protection Overload, Short-Circuit
Specification 6kA at AC240/415V
- 1P, 1P+N, 2P, 3P, 3P+N, 4P
- Ics = 100% Icu
- Energy Limit Class 3
- Characteristics Curves C and
Curves D
- IP20
Accessory
- Auxiliary contact
- Alarm trip
- Shunt trip
- Under voltage trip

Rated current Price


Item Diagram Order Code
In (A) (THB)
6A,10A,16A,20A HGD63M
170
25A,32A 1PMCS0000X 000xx

HGD63M
40A,50A,63A 200
1PMCS0000X 000xx

HGD63M
16A,20A,25A,32A 350
2PMCS0000X 000xx

HGD63M
40A,50A,63A 400
2PMCS0000X 000xx

6A,10A,16A,20A HGD63M
510
25A,32A 3PMCS0000X 000xx

HGD63M
40A,50A,63A 600
3PMCS0000X 000xx

HGD63M
16A,20A,25A,32A 700
4PMCS0000X 000xx

HGD63M
40A,50A,63A 800
4PMCS0000X 000xx

※ Miniature circuit breaker 1P,2P,3P ขนาดกระแส 1-5A โปรดติดต่อตัวแทนจำาหน่าย


30
HGD63P, 63 AF, 10 kA
HRC Moular Devices

Standard IEC/EN 60898-1


Protection Overload, Short-Circuit
Specification 10kA at AC240/415V
- 1P, 1P+N, 2P, 3P, 3P+N, 4P
- Ics = 75% Icu
- Energy Limit Class 3
- Characteristics Curves C and
Curves D
- IP20
Accessory
- Auxiliary contact
- Alarm trip
- Shunt trip
- Under voltage trip

Rated current Price


Item Diagram Order Code
In (A) (THB)

6A,10A, 16A,20A
HGD63P 1PMCS0000X
25A,32A,40A,50A 300
000xx
63A

16A,20A,25A,32A, HGD63P 2PMCS0000X


600
40A,50A,63A 000xx

16A,20A,25A,32A, HGD63P 3PMCS0000X


900
40A,50A,63A 000xx

16A,20A,25A,32A, HGD63P 4PMCS000X


1,200
40A,50A,63A 000xx

※ Miniature circuit breaker 1P,2P,3P ขนาดกระแส 1-5A โปรดติดต่อตัวแทนจำาหน่าย

31
Product Price List

HGD100S,100 AF, 10 kA

HRC Moular Devices


Standard IEC/EN 60898-1
Protection Overload, Short-Circuit
Specification 10kA at AC240/415V
- 1P, 1P+N, 2P, 3P, 3P+N, 4P
- Ics = 75% Icu
- Energy Limit Class 3
- Characteristics Curves C
- IP20
Accessory Auxiliary contact
Alarm trip Shunt trip
Under voltage trip

Rated current In (A) Price


Item Pole Order Code
C curve (THB)
63A HGD100S 1PMCS0000C 00063 800

1P 80A HGD100S 1PMCS0000C 00080 800

100A HGD100S 1PMCS0000C 00100 800

63A HGD100S 2PMCS0000C 00063 1,600

2P 80A HGD100S 2PMCS0000C 00080 1,600

100A HGD100S 2PMCS0000C 00100 1,600

63A HGD100S 3PMCS0000C 00063 2,400

3P 80A HGD100S 3PMCS0000C 00080 2,400

100A HGD100S 3PMCS0000C 00100 2,400

63A HGD100S 4PMCS0000C 00063 3,200

4P 80A HGD100S 4PMCS0000C 00080 3,200

100A HGD100S 4PMCS0000C 00100 3,200

63A HGD100S 1NMCS0000C 00063 1,500

1+N 80A HGD100S 1NMCS0000C 00080 1,500

100A HGD100S 1NMCS0000C 00100 1,500

63A HGD100S 3NMCS0000C 00063 3,000

3+N 80A HGD100S 3NMCS0000C 00080 3,000

100A HGD100S 3NMCS0000C 00100 3,000

32
Residual Current Circuit Breaker (RCCB)
HRC Moular Devices

Standard IEC/EN61008
HRC63S, 63 AF/30mA , HRC100S,100 AF/30mA Protection earth leakage
Specification HRC100S : 63, 80, 100A
HRC63S: 16, 25, 32, 40, 50, 63A
- 30mA
- 2 (N+1), 4 (N+3) pole
- A type

Rated current In Price


Item Diagram Order Code
(A) (THB)

HRC63S 2PG4S0000C
16, 25, 32, 40, 50, 63A 1,800
000xx

63 AF
2P(N+1), 30mA

HRC63S 4PG4S0000C
16, 25, 32, 40, 50, 63A 2,300
000xx

63 AF
4P(N+3), 30mA

HRC100S 2PG4S0000C
63, 80, 100A 2,800
00xxx

100 AF
2P(N+1), 30mA

HRC100S 4PG4S0000C
63, 80, 100A 4,000
00xxx

100 AF
4P(N+3), 30mA

33
Product Price List

Residual Current Circuit Breaker With Overcurrent Protection (RCBO)

HRC Moular Devices


34
| HG-Series | Miniature circuit breaker
HR040hT,40 AF , 10kA (with Cable) Standard IEC/EN 61009-1
Protection Earth leakage , Over current
HR063B, 63 AF , 10kA Specification 10 kA at AC240V
HRO40hT,40 AF ,10kA (with Cable)
- 10, 16, 20, 25, 32, 40, 50, 63A
- HR040hT : 1P+N (1 module)
HRO63B, 63 AF ,10kA - HR063B : 2P (2 module)
- 10 kA (lcs = 75% Icu)
- 30 mA
- AC type
Residual Current Circuit Breaker Standard
- C Curve
IEC/EN 61009-1
Protection Earth leakage , Over current
with Overcurrent Protection -Specification
IP20 10 kA at AC240V
- 10, 16, 20, 25, 32, 40, 50, 63A
- HRO40hT : 1P+N (1 module)
- HRO63B : 2P (2 module)
- 10 kA (Ics = 75% Icu)
- 30mA
- AC type
- C Curve
- IP20

909-2548

Item Diagram Rated current In (A) Order Code Price (THB)


For feeder

10, 16, 20, 25, 32, 40 HRO40HT 1NG4C0000C 000xxG 2,600

1P + N (1module)
For main
TEST
1 3
16, 20, 25, 32, 40,50,63 HRO63B 2PG4C0000C 000xxG 2,800
B

2 4

2P (2module)

Remark : Please contact us for the price of RCBO


Remark : Please contact us for the price of RCBO

34
General Specification Panel Board
IEC 61439-3
Busbar ทำาจากทองแดงชุบดีบุกเป็นชิ้นเดียวไม่มี
HRC Moular Devices

รอยต่อแท่ง N,G ทำาจากทองเหลือง


Grounding ระหว่างตัวตู้กับฝาตู้
ติดตั้งบนราง Dinrail EN50022 แบบ Snap On
ขนาด 35 x 7.5 mm
การพ่ นสี 60 Micro และอบด้วยความร้อน 200°c

Dimension Price
Item Panel Board MODEL
(WxHxD) (THB)
-12 Modules PB12MB100 400x600x125 8,300

-18 Modules PB18MB100 400x650x125 10,000

-24 Modules PB24MB100 400x650x125 11,100


Main.CB 100A
-30 Modules PB30MB100 400x700x125 12,250

-36 Modulcs PB36MB100 400x800x125 13,900

-42 Modules PB42MB100 400x800x125 15,000

-18 Modules PB18MB250 400x650x125 12,200

-24 Modules PB24MB250 400x650x125 14,400

Main.CB 250A -30 Modules PB30MB250 400x700x125 15,500

-36 Modulcs PB36MB250 400x800x125 16,600

-42 Modules PB42MB250 400x800x125 18,850

-18 Modules PB18ML250 400x500x125 11,100

-24 Modules PB24ML250 400x500x125 12,200

Main.Lug 250A -30 Modules PB30ML250 400x600x125 13,300

-36 Modulcs PB36ML250 400x650x125 14,400

-42 Modules PB42ML250 400x650x125 15,550

Technical Specification :

Maximum busbar rated : 250A


Rate Voltage : 240/415V 50Hz
Matcrial : Electro Galvanized Steel
Thickness : 1.0 m.m.
Degree Of Protection (IP): IP 4x
Neutral terminal capacity Incoming up to 50 mm2 / Outgoing up to 16 mm2
Ground terminal capacity Incoming up to 50 mm2 / Outgoing up to 16 mm2
Color: C130132A (Ice Wool) Epoxy Powder Paint Coating

35
Product Price List

HRC Moular Devices


Consumer Unit Standard Type Split bus Type
Model HRDB06W HRDB10W HRSB14W HRSB19W
Description 8Ch (Main+6 Ways) 12Ch (Main+10 Ways) 16Ch (Main+14 Ways) 21Ch (Main+19 Ways)
Price (THB) 1,550 1,850 2,100 2,400
Trchnical
Specification
Dimension
260x220x90 320x220x90 359x210x88.7 450x210x88.7
(WxHxD) mm.
Maximum busbar
160A
rated
Rate Voltage : 240/415V 50Hz
Material : Electro Galvanized Steel
Thickness : 0.8 mm. 1.2 mm.
Degree of Protec-
IP 42 IP 40
tion (IP) :
Neutral terminal
Incoming up to 16 Sq.mm / Outgoing up to 10 Sq.mm
capacity
Ground terminal
Incoming up to 16 Sq.mm / Outgoing up to 10 Sq.mm
capacity
Color : Peal white Epoxy Powder Paint Coating White (RAL9003)

36
HRC Moular Devices

Wiring Diagrams

การต่อแบบมีเซอร์กิตเบรกเกอร์เป็น
เมนไม่มีอุปกรณ์ป้องกันไฟรั่วไฟดูดใน
วงจรย่อย
- ป้องกันอันตรายจากไฟเกินและไฟช๊อต
- ต้องติดตั้งสายดินให้ถูกต้องตามมาตรฐาน
การไฟฟ้า เพื่ อป้องกันอันตรายจากไฟรั่ว
ไฟดูดเบื้องต้น สำาหรับวงจรที่ไม่ต่อผ่่าน
อุปกรณ์ป้องกันไฟรั่วไฟดูด

การต่อแบบมีเซอร์กิตเบรกเกอร์เป็น
เมน และมีลูกย่อยเป็นอุปกรณ์ป้องกัน
ไฟรั่วไฟดูด
ป้องกันอันตรายจากไฟเกินและไฟช๊อต
- ป้องกันอันตรายจากไฟรั่วไฟดูดได้ โดยจะ
ป้องกันแบบวงจรต่อวงจร สำาหรับวงจรที่
ต่อผ่่าน RCBO เท่านัน้
- ต้องติดตั้งสายดินให้ถูกต้องตามมาตรฐาน
การไฟฟ้า เพื่ อป้องกันอันตรายจากไฟรั่วไฟ
ดูดเบื้องต้น สำาหรับวงจรที่ไม่ต่อผ่่าน
อุปกรณ์ป้องกันไฟรั่วไฟดูด

การต่อแบบมีเซอร์กิตเบรกเกอร์เป็น
เมน และมีอุปกรณ์ป้องกันไฟรั่วไฟดูด
เป็นเมน RCBO สำาหรับแยกควบคุม
(split bus)
ป้องกันอันตรายจากไฟเกินและไฟช๊อต
- ป้องกันอันตรายจากไฟรั่วไฟดูดได้ โดย
จะป้องกันเฉพาะวงจรที่ต่อผ่่านเมน RCBO
เท่านั้น
- การต่อวงจรในรูปแบบนี้ต้องเพิ่ ม Neutral
Terminal แยกอีก 1 ชุด
- ต้องติดตั้งสายดินให้ถูกต้องตามมาตรฐาน
การไฟฟ้า เพื่ อป้องกันอันตรายจากไฟรั่ว
ไฟดูดเบื้องต้น สำาหรับวงจรที่ไม่ต่อผ่่าน
อุปกรณ์ป้องกันไฟรัว ่ ไฟดูด

37
Product Price List

Project Reference
Essential for today
Potential for Tomorrow

171
สนใจติดต่อตัวแทน
Tel : +66 (0)2 002 - 4395 - 7
Fax : +66 (0)2 002 - 4398
www.tdpowertech.com