Professional Documents
Culture Documents
Installation Instructions
1
NOTE: Installation wiring for the product and wiring methods shall be in accordance with the National Electrical
Code, ANSI/NFPA 70.
Product Components
1
1500 Series or 1600 Series Electric Strike 3 Pigtails (12 VDC and 24 VDC) 5 #6-32 x 3/16” Phillips Head
2
Trim Enhancer 4 5/64” Hex Wrench Screws to Mount Trim Enhancer
2
3
4 5
Specifications
Solenoids are rated at +/- 10% indicated value. VOLTAGE
ELECTRICAL RATINGS FOR
* Applies to AC Only: 10% max duty cycle
1500/1600 (Solenoid) MINIMUM WIRE GAUGE REQUIREMENTS
(2 min. max on time) 12VDC 24VDC
NOTE: The above table applies to Models 1500, 1500E, 1600, and 1600E.
ELECTRICAL RATINGS FOR
Input voltage: 10–30 VDC, Autosensing
1500E/1600E (EcoStrike™)
Minimum Activation Duration: 1 second
Models 1500E and 1600E: For Indoor Use Only
VOLTAGE 10 VDC 12 VDC 24 VDC 30 VDC
Models 1500 and 1600: For Outdoor Use
IN RUSH CURRENT 0.475A 0.460A 0.220A 0.215A
VIOLET
(+ 12 VDC)
ELECTRIC
STRIKE
RED (+ 24 VDC)
VIOLET
ELECTRIC
STRIKE
CONNECT
TOGETHER
BLACK
RED/GREEN
(-NEG)
3
Mortise
Vertical Strike Vertical Strike
Lockset Centerline Prep Cylindrical Centerline Prep
Lock
CL
Strike CL
4" STRIKE
[101.6 mm]
5/8"
1-1/4" [15.88 mm]
[31.8 mm]
1-3/4" 1-1/4" 5/8"
1-1/4" [15.88 mm]
[44.45 mm] [31.8 mm] [31.8 mm]
* Can be Mortise lock and option specific. See figures below if 1-3/4" 1-1/4"
[44.45 mm] [31.8 mm]
using a Schlage L9000 or Yale 8700 series.
NOTE: Cannot be used with Schlage L9000 or Yale 8700 series. NOTE: Can be used with Schlage L9000 or Yale 8700 series.
Cutout dimenstions for option faceplates (metal jamb): 1J, 1KM, 1NM Cutout dimenstions for option faceplates (metal jamb): 1KD, 1ND, 1NTD
CL 5/32”
19/32”
[15.08 mm]
2X 12-24
2X 12-24 UNC THREADS
1-1/4" UNC THREADS 1-1/4"
[31.8 mm]
[31.8 mm]
1J 1K 1KM 1KD
STEP 1
LOOSEN the locking screw with the
5/64” Hex Wrench.
STEP 2
ADJUST the shim height to the desired level
by turning the upper and lower set screws
(clockwise to raise and counterclockwise
to lower).
STEP 3
TIGHTEN the locking screw to lock position.
6
HES, Inc.
Phoenix, AZ
800-626-7590