Professional Documents
Culture Documents
Magistarski rad
Mentor: Kandidat:
УДК
Чува се, ЧУ: Библиотека ФТН, Нови Сад, Трг Доситеја Обрадовића 6
Важна напомена, ВН: Нема
Title, TI: Aspect of modeling of synchronous motors with salient pole in transient and
in steady-state asynchronous regime
Language of text, LT: Serbian
Language of abstract, LA: English/Serbian
Country of publication, CP: Serbia
Locality of publication, LP: Vojvodina, Novi Sad
Publication year, PY: 2008
Publisher, PB: Author’s reprint
Publication place, PP: Novi Sad, Trg Dositeja Obradovića 6
Physical description, PD: 11/97/13/110
(chapters/pages/ref./pictures)
Note, N: None
Abstract, AB: This master’s thesis deals with simulations of synchronous motors in
asynchronous regime. Different asymmetries are realized with the help of
models which appeared in the following cases: at asynchronous starting,
synchronization, the sudden change of load and break the current of the
exciting coils. This work presents in detail the theoretical background
important for understanding this thesis. A concrete synchronous motor is
simulated in this thesis. Following the simulation the diagrams were drawn
showing the change of effective values of the current at the asynchronous
start using complex equations. The aim was to prove the validity of the model
which was used. Based on the results of the simulation a novel approach is
made: the appropriate polarity of the supply voltage of exciting coils was
determined. The results of the experiments are identical with the results of
the simulations, whereby the suitability of model is proven.
Accepted by the Scientific Board on, ASB:
Defended on, DE:
Defended Board, DB: President: Dr. Borislav Jeftenić, vanr. prof., ETF Beograd
Member: Dr Vladimir Katić, red. prof., FTN Novi Sad
Member: Dr Darko Marčetić, docent, FTN, Novi Sad Menthor's sign
Member: Dr Filip Kulić, vanr. prof., FTN, Novi Sad
Member, Mentor: Dr Veran Vasić, vanr. prof., FTN, Novi Sad
Obrazac Q2.НА.06-05- Izdanje 1
SADRŽAJ
SADRŽAJ ......................................................................................................................2
SPISAK PRIMENJENIH SIMBOLA............................................................................4
1. UVOD ........................................................................................................................9
1.1 Primena sinhronih motora..............................................................................9
1.2 Osnovni pojmovi simulacije ........................................................................10
2. SINHRONI MOTORI..............................................................................................12
2.1 Konstrukciona izvedba sinhronih motora ..........................................................12
2.1.1 Sihnroni motori sa permanentno magnetnom pobudom.................................13
2.1.2 Sinhroni motori sa rotorskim jednosmernim strujnom pobudom ...................14
2.2 Opis asinhronog pokretanja sinhronog motora sa izraženim polovima.............16
3. PROSTORNI VEKTORI U PRIRODNIM KOORDINATNIM SISTEMIMA......19
3.1 Prostorni vektori statora u prirodnom koordinatnom sistemu ...........................20
3.1.1 Prostorni vektori statorskih napona ................................................................21
3.1.2 Prostorni vektor statorskih struja ....................................................................22
3.1.3 Prostorni vektor obrtne magnetopobudne sile ................................................22
3.1.4 Prostorni vektor fluksnih obuhvata.................................................................23
3.2 Prostorni vektori rotora u prirodnom koordinatnom sistemu ............................24
3.3 Veza između prostornih vektora fluksnih obuhvata i prostornih vektora struje 24
3.4 Naponske diferencijalne jednačine statora i rotora u prirodnim koordinatnim
sistemima .................................................................................................................25
4. PROSTORNI VEKTORI I JEDNAČINE U ZAJEDNIČKOM OPŠTEM
KOORDINATNOM SISTEMU ..................................................................................26
4.1 Transformacija vektora iz prirodnih koordinatnih sistema u zajednički opšti (K)
koordinatni sistem....................................................................................................27
4.2 Veza između vektora fluksnih obuhvata i vektora struje preko induktivnosti
statora i rotora ..........................................................................................................28
4.3 Naponske jednačine u zajedničkom opštem koordinatnom sistemu..................28
4.4 Rasprezanje prostornih vektora i naponskih jednačina na skalarne komponente
..................................................................................................................................29
4.5 Način rasprezanje prostornih vektora u trenutne vrednosti po fazama..............31
5 NAČIN SIMULACIJE UTICAJA GUBITAKA SNAGE U GVOŽĐU STATORA
......................................................................................................................................34
5.1 Opšti sistem vektorskih naponskih diferencijalnih jednačina sa otporom
gubitaka u gvožđu ....................................................................................................35
5.2 Opšti oblik skalarnih diferencijalnih jednačina sa otporom gubitaka u gvožđu
..................................................................................................................................36
5.3 Trenutne snage i trenutni gubici snage ..............................................................38
5.4 Stadarni oblici trenutne vrednosti proizvedenih eletromagnetnih momenata....39
5.5 Skalarne naponske diferencijalne jednačine sinhronog motora sa izraženim
polovima u zajedničkom rotorskom koordinatnom sistemu....................................40
5.6 Skalarni oblici trenutne vrednosti proizvedenih eletromagnetnih momenata....41
5.7 Njutonova jednačina obrtnog kretanja ...............................................................42
6. USTALJENI REŽIM SINHRONOG MOTORA ....................................................43
2
6.1 Ustaljeni asinhroni režim sinhronog motora......................................................43
6.1.1 Snage i gubici snage........................................................................................46
6.1.2 Bilans reaktivne snage ....................................................................................47
6.1.3 Jednačine momenta.........................................................................................47
6.2 Ustaljeni sinhroni režim sinhronog motora........................................................48
6.2.1 Snage i gubici snage........................................................................................50
6.2.2 Bilans reaktivne snage ....................................................................................50
6.2.3 Jednačine momenta.........................................................................................51
7. SIMULACIJE SINHRONIH MOTORA SA IZRAŽENIM POLOVIMA U
PRELAZNIM REŽIMIMA .........................................................................................52
7.1 Asinhroni zalet sinhronog motora......................................................................54
7.1.1 Asinhroni zalet sinhronog motora sa otvorenom pobudnim kolom i bez
predimpedansa .........................................................................................................54
7.1.2 Asinhroni zalet sinhronog motora sa kratkospojenim pobudnim namotajem
bez predimpedansa...................................................................................................56
7.1.3 Asinhroni zalet sinhronog motora sa kratkospojenim pobudnim namotajem i
predimpedansom ......................................................................................................58
7.1.4 Asinhroni zalet sinhronog motora sa zaštitnom otpornikom bez
predimpedansa .........................................................................................................60
7.2 Simulacije pojava koja se dešavaju pri sinhronizacije.......................................62
7.2.1 Sinhronizacija pri pozitivnoj struji i pozitivnim izvodom struje pobudnog
namotaja...................................................................................................................62
7.2.2 Sinhronizacija sa pozitivnom strujom i negativnom izvodom struje pobudnog
namotaja...................................................................................................................64
7.2.3 Sinhronizacija sa negativnom strujom i pozitivnom izvodom struje pobudnog
namotaja...................................................................................................................66
7.2.4 Sinhronizacija sa negativnom strujom i negativnim izvodom struje pobudnog
namotaja...................................................................................................................68
7.2.5 Sinhronizacija uz pomoć reluktantnog momenta............................................70
7.2.6 Uključivanje napajanja pobudnog namotaja sa nepravilnim pobudom ..........71
7.2.7 Uključivanja napajanja pobudnog namotaja sa pravilnom pobudom .............73
7.3 Modelovanje pojava pri nagloj promeni opterećenja.........................................75
7.4 Simulacije pojava koje se javljaju u slučajevima prekida u dovodu pobudne
struje.........................................................................................................................78
8. ANALIZA RADA SINHRONIH MOTORA SA IZRAŽENIM POLOVIMA U
USTALJENIM REŽIMIMA........................................................................................81
8.1 Spori asinhroni zalet ..........................................................................................81
8.1.1 Zalet sa otvorenim pobudnim namotajem bez predimpedansa.......................81
8.1.2 Zalet sa kratkospojenim pobudnim namotajem ..............................................82
8.1.3 Zalet sa kratkospojenim pobudnim namotajem i predimpedansom ...............83
8.1.4 Zalet sa zaštitnom otpornikom........................................................................84
8.1.5 Zalet sa zaštitnom otpornikom i predimpedansom .........................................86
9. REZULTATI MERENJA ........................................................................................87
9.1 Rezultati merenja asinhronih zaleta ...................................................................87
9.2 Rezultati merenja sinhronizacije........................................................................90
9.3 Rezultati merenja pri nagloj promeni opterećenja .............................................92
9.4 Rezultati merenja za slučaj prekida pobudne struje...........................................94
10. ZAKLJUČAK ........................................................................................................96
11. LITERATURA ......................................................................................................98
3
SPISAK PRIMENJENIH SIMBOLA
ω - električna ugaona brzina rotora
θ - ugaono zakretanje realne ose rotorskog prirodnog koordinatnog
sistema u odnosu na realnu osu statorskog prirodnog koordinatnog
sistema
θ0 - početno ugaono zakretanje realne ose rotorskog prirodnog
koordinatnog sistema u odnosu na realnu osu statorskog prirodnog
koordinatnog sistema
a - jedinični kompleksni operator
u a , ub , uc - trenutne vrednosti faznih napona.
ua ,ub ,uc - trenutne prostornih vektora faznih namotaja.
us - prostorni vektor statorskih napona.
i a , ib , i c - trenutne vrednosti faznih struja.
is - prostorni vektor statorskih struja.
F -prostorni vektor statorskih magnetopobudnih sila
NK -broj navojaka u kalemu
Fa , Fb , Fc - trenutne vrednosti amplitude osnovnog harmonika njihovih
magnetopobudnih sila po polovima
Ns -broj navojaka po fazama statora
ξs -navojni sačinilac namotaja statora
p -broj pari polova namotaja statora
ψs - fluksni obuhvat statorskih namotaja
ψ a ,ψ b ,ψ b - fluksni obuhvati pojedinačnih statorskih faznih namotaja
ur a , u rb , u rc - trenutne vrednosti faznih napona rotora.
ur - prostorni vektor rotorskih napona.
ir a , irb , irc - trenutne vrednosti faznih struja rotora.
ir - prostorni vektor rotorskih struja.
ψ r a ,ψ rb ,ψ rc - trenutne vrednosti faznih fluksnih obuhvata rotora.
ψr - prostorni vektor rotorskih fluksnih ouhvata.
Lsσ -trofazna rasipna induktivnost statora.
Lrσ - svedena vrednost trofazne rasipne induktivnosti rotora na stator.
Lm - trofazna induktivnost magnetiziranja.
Ls - ukupna trofazna induktivnost statora ( Ls = Lsσ + Lm )
Lr - ukupna trofazna induktivnost rotora ( Lr = Lrσ + Lm )
Rs - otpornost statorskih namotaja po fazama,
Rr - svedena otpornost rotorskih namotaja po fazama.
ωk - ugaona brzina opšteg koordinatnog sistema.
4
θk - ugaono zakretanje realne ose zajedničkog opšteg koordinatnog
sistema u odnosu na realnu osu statorskog prirodnog koordinatnog
sistema.
θ k (0) - početno ugaono zakretanje realne ose zajedničkog opšteg
koordinatnog sistema.
i sk -prostorni vektor statorskih struja u opštem zajedničkom koordinatnom
sistemu.
u sk -prostorni vektor statorskih napona u opštem zajedničkom
koordinatnom sistemu.
ψ sk - prostorni vektor statorskih fluksnih obuhvata u opštem zajedničkom
koordinatnom sistemu.
i rk - prostorni vektor rotorskih struja u opštem zajedničkom koordinatnom
sistemu.
u rk - prostorni vektor rotorskih napona u opštem zajedničkom
koordinatnom sistemu.
ψ rk - prostorni vektor rotorskih fluksnih obuhvata u opštem zajedničkom
koordinatnom sistemu.
i mk - prostorni vektor struje magnetiziranje.
u sdk , u sqk - skalarne komponente statorskih napona u opštem zajedničkom
koordinatnom sistemu.
i sdk , i sqk - skalarne komponente statorskih struja u opštem zajedničkom
koordinatnom sistemu.
ψ sdk ,ψ sqk - skalarne komponente statorskih fluksnih obuhvata statora u opštem
zajedničkom koordinatnom sistemu.
u rdk , u rqk - skalarne komponente rotorskih napona u opštem zajedničkom
koordinatnom sistemu.
irdk , irqk - skalarne komponente rotorskih struja u opštem zajedničkom
koordinatnom sistemu.
ψ rdk ,ψ rqk - skalarne komponente rotorskih fluksnih obuhvata statora u opštem
zajedničkom koordinatnom sistemu.
imdk , imqk - skalarne komponente struja magnetiziranje u opštem zajedničkom
koordinatnom sistemu.
u so - trenutna vrednost nulte komponente statorskih napona,
iso - trenutna vrednost nulte komponente statorskih struja.
uro - trenutna vrednost nulte komponente rotorskih napona,
iro - trenutna vrednost nulte komponente rotorskih struja.
PFe - gubici u gvožđu statora
B - indukcija
e - trenutna vrednost indukovanog napona.
e mk - vektor indukovanog napona.
ψ mk - vektor fluksnog obuhvata magetiziranja
ψ sσk - rasipni fluksni obuhvat statora,
5
ψ rσk - rasipni fluksni obuhvat rotora.
Rm - otpornost gubitaka u gvožđu.
i Fek - struja gubitaka u gvožđu statora.
ik - struja statora bez struje gubitaka u gvožđu.
i Fedk , i Feqk - skalrni komponente struje gubitaka u gvožđu.
idk , iqk - skalarne komponente struje statora bez komponente struje gubitaka u
gvožđu.
p1 - trenutna vrednost primljene snage.
p cus - trenutna vrednost gubitaka snage u bakru statora.
p cur - trenutna vrednost gubitaka snage u bakru rotora.
p Fes - trenutna vrednost gubitaka snage u gvožđu statora.
pm - trenutna vrednost proizvedene mehaničke snage.
p sσ a - trenutna vrednost gubitaka snage usled akumulacije na induktivnost
rasipanja statora.
p rσ a - trenutna vrednost gubitaka usled akumulacije na induktivnost
rasipanja rotora.
pma - trenutna vrednost gubitaka usled akumulacije na induktivnost
magnetiziranje.
me - trenutna vrednost proizvedenog momenta motora.
mm - trenutna vrednost proizvedenog momenta na vratilu motora.
mtrv - trenutna vrednost momenta trenja i ventilacije.
Ω - mehanička ugaona brzina,
JΣ - zbir momenta inercije motora i radne mašine.
u sd , u sq -skalarne komponente statorskog napona.
i sd , isq - skalarne komponente statorske struje.
imd , imq - skalarne komponente struje magnetiziranje.
i Fed , i Feq - skalarne komponente struje gubitaka u gvožđu statora.
id , iq - skalarne komponente struje statora bez komponenata struje gubitaka
u gvožđu.
uf - napon pobudnog namotaja svedena na statorsku stranu.
Rf - otpornosti pobudnog namotaja svedena na statorsku stranu.
if - struja pobudnog namotaja svedena na statorsku stranu.
L fσ - rasipna induktivnost pobudnog namotaja svedena na statorsku stranu.
R Dd , RDq - otpornosti prigušnog kaveza u uzdužnom i poprečnom smeru svedeno
na stator.
i Dd , i Dq - skalarne komponente struje prigušnog kaveza svedene na statorsku
stranu.
LDσd , LDσq - rasipna induktivnost prigušnog kaveza u uzdužnom i poprečnom
smeru svedeno na stator.
6
Lmd , Lmq - magnetizirajuća induktivnost u uzdužnom i poprečnom smeru.
s - klizanje rotora.
U sd ,U sq - kompleksni komponenti napona statora
U - efektivna vrednost napona
Z11 , Z 22 , Z 33 ,......., Z 77 -sopstvene impedanse
Z 12 , Z 13 , Z 14 ,......., Z 17 -međusobne impedanse.
XV - predimpenansa.
Rz - zaštitni otpornik svedeno na statorskoj strani.
X fσ - rasipni reaktansa pobudnog namotaja svedena na statorskoj strani.
X Dσd , X Dσq - rasipne reaktanse prigušnog kaveza u uzdužnom i poprečnom smeru,
svedena na statorsku stranu.
X md , X mq - magnetizirajuće reaktanse u uzdužnom i poprečnom smeru.
I sd , I sq -efektivne vrednosti komponenata statorske struje,
I Dd , I Dq -efektivne vrednosti komponenata struje prigušnog kaveza svedene na
statorsku stranu.
If - efektivna vrednost struje pobudnog namotaja svedena na statorsku
stranu.
I md , I mq - efektivne vrednosi komponenata struje magnetiziranja.
I Fed , I Feq - efektivne vrednosti komponenata struje gubitaka u gvožđe statora.
Id , Iq - efektivne vrednosti komponenata struje statora bez struje gubitaka u
gvožđe statora.
Ps - primljena snaga.
Pf - primljena snaga pobude.
P2 - proizvedena snaga.
Pm -odata mehanička snaga na vratilu motora:
Ptrv -gubici trenja i ventilacija.
Pcus - gubici snage u bakru statora.
PFes - gubici snage u gvožđu statora
PcuD - gubici snage u prigušnom kavezu.
Pcuf -gubici u pobudnom namotaju.
Pz - gubitaka snage na zaštitnom otporniku.
Qs -primljena reaktivna snaga.
Qsσ - reaktivna snaga na reaktansi rasipanja statora.
QD - reaktivna snaga na reaktansi rasipanja prigušnog kaveza.
Q fσ - reaktivna snaga na reaktansi rasipanja pobudnog namotaja.
Qm - reaktivna snaga na reaktansama magnetiziranja.
Me -proizvedeni električni moment.
Mm - mehanički moment na vratilu motora.
M trv -moment gubitaka trenja i ventilacije.
7
γ ,δ -ugao između prostornog vektora napona i osa d koordinatnog sistema.
Ki - koeficijent svođenja struje pobudnog namotaja na stator
Ku - koeficijent svođenja napona pobudnog namotaja na stator
Kr - koeficijent svođenja otpornosti pobudnog namotaja na stator
Rp - otpornost pobudnog namotaja
X pσ - rasipna rektansa pobudnog namotaja
ZV -predimpedansa
Rzr - zaštitni otpornik
8
1. UVOD
9
Oscilacija proizvodnje i potrošnje električne energije je veliki problem današnjih
energetskih sistema jer se veći deo električne energije proizvodi u termoelektranama
(nuklearna elektrana je jedna vrsta termoelektrane). Ove elektrane imaju najbolji
stepen korisnog dejstva na određenoj snazi, šta znači da je poželjno da daju u
električnu mrežu upravo tu snagu i to konstantno.
Svakako se snaga elektrane može regulisati u određenim granicama koje još
obezbeđuju podnošljivi stepen koristnog dejstva, a van tih granica treba isključiti
elektranu. Isključenje elektrane se vrši veoma retko jer je to ne ekonomično (na
primer puštanje jednog nuklearnog reaktora u pogon traje nekoliko meseci). Sa druge
strane, potrošnja električne energije se menja iz sekunde u sekundu što znači da treba
kontinualno regulisati nivo proizvodnje električne energije.
Problem neravnoteže između proizvodnje i potrošnje električne energije se može
ublažiti akumulisanjem električne energije primenom reverzibilnih hidroelektrana. U
intervalima, kada se u mreži javlja višak električne energije vraća se voda u
akumulaciono jezero, preko odgovarajućih pumpnih postrojenja.
U elektranama se koriste sinhroni generatori, pa je ekonomičnije da se ista
mašina koristi kao pogonski motor pumpe koja vraća vodu u akumulaciono jezero.
To znači da je možda ekonomičnije rešiti regulaciju sinhronog mašina, što je
jednostavnije, nego ugraditi asinhroni motor kome treba rešiti kompenzaciju reaktivne
snage ili treba primeniti frekventni pretvarač.
10
ugaone brzine referentnog koordinatnog sistema u kojoj su napisane naponske
jednačine.
U električnim mašinama često nastaju asimetrije. Poznavanje ponašanja
električne mašine pri ovim asimetrijama je bitno, da bi se u praksi izbegle pojave
kvarova koje su nastale usled njih. Ove asimetrije mogu biti slučajne (prekid dovoda
jedne faze) i namerne (asinhroni motor sa zasenčenim polovima) asimetrije.
Simulacija asimetrije koja nastaje u jednom od koordinatnih sistema se može
obaviti samo u istom sistemu gde nastaje asimetrija, jer pri transformaciji veličina iz
jednog koordinatnog sistema u drugi pojavljuju se trigonometrijske funkcije tangens
ili kotangens, koje nisu kontinualne.
Na osnovu ovoga, prethodno navedeni sinhroni motor sa izraženim polovima se
može modelirati u “rotorskom“ koordinatnom sistemu, jer se asimetrija nalazi u
rotoru.
U radu je simuliran sinhroni motor sa izraženim polovima uz pomoć
matematičkog softvera “Mathcad 2001 Profesional“. Prednost ovog programa je da se
problem može tretirati preglednim matematičkim izrazima, koji omogućavaju
korišćenje indeksa za označavanje različitih veličina.
Matematički model sinhronog motora korišćen u ovom radu uzima u obzir
gubitak snage u gvožđu statora, dok je gubitak snage u gvožđu rotora zanemaren, jer
se inače ovaj gubitak u blizini sinhronizma može zanemariti. U toku ovoga rada
simuliran je asinhroni zalet sinhronog motora, sinhronizacije, uticaj promene
opterećenja i ispad iz sinhronizma.
Poznavanje električnih veličina, koje se javljaju u prethodnim navedenim
prelaznim pojavama je bitno pri projektovanju zaštita sinhronih motora. Zbog
jednostavnijeg određivenja navedenih električnih veličina iz diferencijalnih jednačina
su određene kompleksne jednačine za ustaljeni asinhroni režim.
11
2. SINHRONI MOTORI
Ip
Ф
Stator
N
ω=ω1
Rotor
β
S
12
snage u gvožđu. Kod sinhronih motora, u normalnim režimima gubici snage u gvožđu
se javljaju samo u gvožđu statora, jer se u rotoru se ne menja indukcija. Gubici snage
u gvožđu se smanjuju eliminisanjem viših harmonika iz raspodele magnetopobudne
sile, što se postiže sinusoidalnom raspodelom magnetne indukcije po unutrešnjem
obimu statora.
Povećanje dinamike često smanjuje stepen koristnog dejstva motora. Poznate su
različite metode za povećavanje dinamike. Među njima su smanjenje prečnika rotora
(povećava se dužina rotora), smanjenje mase rotora, smanjenje rasipne induktivnosti
statora.
Sinhroni motori po izvedbi rotora svrstavaju se u dve kategorije i to:
- sihnroni motori sa permanentno magnetnom rotorskom pobudom.
- sinhroni motori sa rotorskim jednosmernim strujnom pobudom. .
d d
N N
N osa osa N
S S
a.) b.)
Sl 2.1-1. Preseci rotora sinhronih motora sa površinskim magnetima
13
Na slici 2.1-1 a.) je prikazana izvedba polova sa mozaičkim permanentnim
magnetima. Jedan pol se sastoji iz više malih permanentnih magneta. Prednost ove
izvedbe je da omogućava proizvodnju rotora različitih veličina sa permanentnim
magnetima istog tipa.
Na slici 2.1-1 b.) je prikazan rotor sa polovima u segmentnoj izvedbi. Kod ovih
rotora magnet jednog pola je izrađen iz jednog komada. Oblikovanjem polova od
permanentnog magneta može se ostvariti sinusoidalnu raspodelu magnetne indukcije
po unutršnjem obimu statora.
Kod sinhronih motora sa permanentno magnetnim polnim jezgrom magneti su
smešteni u unutrašnjosti rotora ispod feromagnetnog polnog nastavka To rezultuje
nejednakost u magnetnom otporu u kolu rotora po uzdužnom d i u poprečnom q
smeru. Ova nejednakost potiče od feromagnetnih polnih nastavka kroz kojih se
poprečni fluks statora zatvara mimoilazeći permanentne magnete. Uzdužni fluks
statora međutim nasuprot tome prolazeći kroz polni nastavak prolazi i kroz polno
jezgro od permanentnog magneta i zatvara se kroz jaram rotora. Pošto permeabilnost
permanentnih magneta približno ima istu vrednost kao permeabilnost vazduha
podrazumeva se da uzdužni fluks statora na svom putu treba da savladava veći
magnetni otpor. Usled ove razlike kod ovih motora pored momenta permanentne
pobude pojavljuje se i reluktantni moment, koji se pogodnim upravljanjem takođe se
može iskoristiti. Iz ovoga sledi da željeni moment kod ovih motora se može ostvariti
sa manjim permanentnim magnetima, a to dovodi do smanjenja cene motora. Kod
ovih motora pored permanentnih magneta na rotoru često se koristi i kavezni namotaj,
što omogućuje asinhroni zalet.
S q
osa
d
N
N osa
S
Sl. 2.1-2. Poprečni presek rotora sinhronog motora sa unutrašnjim permanentnim
magnetima
14
Struja kaveza i obrtno magnetno polje statora proizvode moment koji pokreće
rotor. Rotor u ovom asinhronom režimu se ubrzava sve dotle dok ne stigne u blizinu
sinhrone brzine obrtanja. U toku trajanja asinhronog zaleta, između krajeva pobudnog
namotaja mora da bude priključen zaštitni otpornik u cilju sprečavanja proboja usled
velikog indukovanog napona pri asinhronom zaletu. Nakon sinhronizacije prigušni
kavez ima zadatak da sprečava nagle promena brzine obrtanja motora ( Leblanov
amartizer), razvijajući moment koji deluje u suprotnom smeru u odnosu na promene
brzine obrtanja rotora. Pored ovih uticaja prigušni kavez ima zadatak da smanjuje
indukovani napon u pobudnom namotaju, čime štiti izvor jednosmernog napajanje od
prenapona.
Valjkasta izvedba rotora se koristi kod sinhronih generatora koji su predviđeni
za rad u sklopu sa brzohodnim parnim turbinama. Valjkasti, odnosno turbo rotori
najčešće su izvedeni u dvopolnoj (Sl. 2.1-3.), a ređe u četvoropolnoj izvedbi. Turbo
rotor se koristi i kod dvopolnih i četvoropolnih motora. Brzina obrtanja ovih motora je
velika, što proizvodi veliku centrifugalnu silu, koja deluje na delove rotora. Magnetno
kolo rotora se proizvodi od dinamo lima, što omogućava jednostavniju proizvodnju, i
rešava problem fiksiranja polova koji se javlja kod rotora sa izraženim polovima.
Željena sinusoidalna raspodela magnetopobudne sile po spoljašnjem obimu rotora kod
valjkastih izvedaba se obezbeđuje pogodnim rasporedom žlebova (najčešće je
ožlebljena samo dve trećine obima rotora). Štapovi prigušnog kaveza kod rotora u
valjkastoj izvedbi su postavljeni u žlebovima koji su simetrično raspoređeni na
celokupnom obimu rotora.
d
osa
N
q
β=120 0 osa
Sinhroni motori sa izraženim polovima se proizvode kao četvoro ili više polni
motori. Ova izvedba rotora (Sl. 2.1-4) se primenjuje kod manjih brzina uz veliki
spoljašnji prečnik rotora, jer centrifugalna sila koja deluje na elemente rotora je
proporcinalna sa kvadratom ugaone brzine i sa prečnikom. To znači da se pri većem
prečniku rotora ista tangencijalna brzina može ostvariti uz manju centrifugalnu silu.
Kod ovih rotora polno jezgro i polni nastavak su fiksirani na različite načine. Pri
svakom rešenju kritičan faktor je dozvoljena granična vrednost centrifugalne sile, koja
je proporcionlna sa kvadratom brzine obrtanja. Magnetno kolo ovih motora je samo
dvoosno simetričan, što znači da u rotorskom koordinarnom sistemu (d i q) uzdužne i
poprečne induktivnosti nisu jednake.
15
S q
osa
Štapovi prigušnog
kaveza
d
N osa
N
S
Sl. 2.1-4. Presek rotora sa izraženim polovima sa jednosmernom strujnom pobudom
16
toga sinhroni motori pri malim opterećenjima mogu ostati u sinhronom radu i nakon
isključenja pobudne struje.
Sinhroni motori, pored asinhronog pokretanja mogu da se nađu i u drugim
asinhronim režimima. Pod asinhronim režimom zbirno podrazumevaju se svi oni
režimi u kojima ugaone brzine sinhronog i rotorskog koordinatnog sistema nisu
jednake. Ti režimi su: asinhroni zalet, tranzijenti režimi koji se odigravaju pri naglom
povećavanju mehaničkog opterećenja, sinhronizacija, ispad iz sinhronizma i daljnji
rad u asinhronom režimu.
L1
L2
US
L3
S1
P S2
is
1.
iDq if
Sinhroni 5. SP
iDd
motor
3. 2. 4.
RM
SR if
iz RZ
Uf
ST + -
TI
~
Sl. 2.2-1. Principijelna šema izvođenja asinhronog pokretanja sinhronog motora sa
izraženim polovima
Kod asinhronog zaleta i u ostalim asinhronim režimima sinhroni motor radi kao
asinhroni motor zahvaljujući prigušnom kavezu. U ovim slučajevima nastaje prekid u
kolu napajanje pobude (može da se dogoditi namerno, ili kao rezultat kvara u
napajanju). Posledica ovoga kvara je da se paralelni spoj zaštitnog otpornika i
pobudnog namotaja pretvara u serijski spoj, te struje u ovim elementima postaju
jednake. Na statorskoj strani ovi uticaji se javljalju u vidu promene amplitude
statorske struje u pojedinim fazama. Pored oscilacije amplituda struje javlja se i
oscilacija momenta, a to dovodi do oscilacije ugaone brzine rotora. Tokom
asinhronog zaleta javlja se sedlo, koje onemogućava asinhroni zalet sinhronog motora
sa većim opterećenjima. U ovom slučaju rotor će se zaglaviti približno kod polovine
sinhrone ugaone brzine.
17
Pri asinhronom zaletu često se dešava da se sinhroni motor sa izraženim
polovima, u blizini sinhrone ugaone brzine uskoči u sinhronizam zahvaljujući
reluktantnom momentu koji se javlja kao rezultat nejednakosti induktivnosti
magnetiziranja u uzdužnom i poprečnom smeru. Ovakav ulazak u sinhronizam je
problematičan jer posle sinhronizacije indukovani napon na priključcima kliznih
prstena je nula, što onemugućuje ispravno određivanje potrebnog polariteta pobudne
struje. To znači da pobudnu struju treba uključiti dok struja pobudnog namotaja nije
jednaka sa nuli, ili treba ugraditi analognu memoriju koja pamti zadnji polaritet struje.
Pri uključivanju pobudne struje sa suprotnim polaritetom, rotor se zaokreće za 1800 u
odnosu na sinhroni obrtni koordinatni sistem. Ova promena će inducirati napon u
pobudnom namotaju što može dovesti do kvara ispravljača za napajanje rotorskog
pobudnog namotaja.
Pri naglim promenama opterećenja kod sinhronih motora nastupaju tranzijentne
pojave. Za vreme tranzijentne pojave ugaona brzina rotora osciluje oko sinhrone
ugaone brzine. Ove promene indukuju napon odnosno struju u prigušnom kavezu,
koja zajedno sa strujom pobudnog namotaja učestvuje u stvaranje trenutne vrednosti
tranzijentnog momenta.
18
3. PROSTORNI VEKTORI U PRIRODNIM
KOORDINATNIM SISTEMIMA
θ = θ 0 + ∫ ω dt (3-1)
19
+Im (S)
ω
+Re (R)
+Im (R) b
STATOR
ib
θ
ar
ira
ia a +Re (S)
br
irb
irc
ROTOR
cr
ic
Sl. 3-1 Prikaz položaja trofaznih namotaja statora i rotora asinhrone mašine u
prirodnim koordinatnim sistemima.
a = e j 2π/3 = −1 / 2 + j 3 / 2 (3-2)
Na taj način prostorni položaj prostornih vektora druge faze, odnosno treće faze
dobija se množenjem njihove trenutne vrednosti sa jediničnim vektorom a odnosno
a2.
Pri čemu je:
a 2 = e j 4π/3 = −1 / 2 − j 3 / 2 (3-3)
20
mogu odrediti tako da se odgovarajuće trenutne vrednosti pomnože sa odgovarajućim
jediničnim kompleksnim operatorima koje određuju njihove ose pulsacije. Zajednički
uticaj svih triju faza kasnije će se odrediti uz pomoć zajedničkih prostornih vektora
koje ćemo dobiti kao zbir prostornih vektora po fazama.
u a = ua
u b = au b (3.1-1)
u c = a uc2
Gde su:
u a , u b , u c - trenutne vrednosti faznih napona.
u a , u b , u c - trenutne prostornih vektora faznih namotaja.
Zajednički prostorni vektor statorskih napona se odruđuje kao 2/3–a zbira
prostornih vektora napona po fazama:
us =
2
3 3
(
(u a + u b + u c ) = 2 u a + a ⋅ u b + a 2 ⋅ u c ) (3.1-2)
Gde je:
u s - prostorni vektor statorskih napona.
Množilac 2/3 pri tom je odabran tako da je realna komponenta prostornog
vektora statorskih napona bude jednak sa trenutnom vrednošću napona prve faze.
Pri simetričnom napajanju za određivanje trenutne vrednosti napona po fazama
mogu se napisati sledeće jednačine:
e j (ωt +ϕ ) + e − j (ωt +ϕ )
u a = Uˆ cos(ωt + ϕ ) = Uˆ
2
e j (ωt +ϕ − 2π / 3) + e − j (ωt +ϕ − 2π / 3)
u b = Uˆ cos(ωt + ϕ − 2π / 3) = Uˆ (3.1-3)
2
j (ωt +ϕ + 2π / 3)
ˆ ˆ e + e − j (ωt +ϕ + 2π / 3)
u c = U cos(ωt + ϕ + 2π / 3) = U
2
21
3.1.2 Prostorni vektor statorskih struja
Prostorni vektor statorskih struja u statorskom prirodnom koordinatnom sistemu
se određuje sličnom analogijom:
2
( )
i s = i a + a ⋅ ib + a 2 ⋅ i c
3
(3.1-5)
Gde su:
i a , ib , ic - trenutne vrednosti faznih struja.
i s - prostorni vektor statorskih struja.
3 N sξ s
F= is (3.1-6)
π p
d FK(x)
FK(x)
x
FK FK1
N
q
0.5τ 0.5τ x
FK
S
a.) b.)
Sl. 3.1-1 Smeštaj namotaja i raspodela magnetopobudne sile kalema sa dijametralnim
korakom
N K I1
FK = (3.1-7)
2
22
Trenutna vrednost amplitude osnovnog harmonika iz pravougaonog signala na
osnovu Fourierovog reda je:
4 2
FK 1 = FK = N K is (3.1-8)
π π
2 N sξ s
Fa = ia
π p
2 N sξ s
Fb = ib (3.1-9)
π p
2 N sξ s
Fc = ic
π p
2 N sξ s 3 N sξ s
F= ⋅ (ia + aib + a 2 ic ) = is (3.1-10)
π p π p
ψs =
2
3
(ψ a + a ⋅ψ b + a 2 ⋅ψ c ) (3.1-11)
23
3.2 Prostorni vektori rotora u prirodnom koordinatnom
sistemu
Ako rotor trofazne mašine poseduje trofazne namotaje, onda prostorni vektori
poprimaju slične oblike kao kod statora. Sa kaveznim rotorom proračune treba
sprovesti sa svedenim veličinama napona i struja na statoru.
Na osnovu rezultata koji su navedeni kod statorskih prostornih vektora izrazi
prostornih vektora rotora su:
Prostorni vektor rotorskih napona:
ur =
2
3
(
u ra + a ⋅ u rb + a 2 ⋅ u rc ) (3.2-1)
Gde su:
ur a , u rb , u rc - trenutne vrednosti faznih napona rotora.
u r - prostorni vektor rotorskih napona.
Prostorni vektor rotorskih struja:
ir =
2
3
(
ira + a ⋅ irb + a 2 ⋅ irc ) (3.2-2)
ψr =
2
3
(
ψ ra + a ⋅ψ rb + a 2 ⋅ψ rc ) (3.2-2)
⎡ψ s ⎤ ⎡ Lsσ + Lm Lm e jθ ⎤ ⎡i s ⎤ ⎡ Ls Lm e jθ ⎤ ⎡i s ⎤
⎢ ⎥=⎢ ⎥⎢ ⎥ = ⎢ ⎥⎢ ⎥ (3.3-1)
⎣⎢ψ r ⎦⎥ ⎣ Lm e
− jθ
Lrσ + Lm ⎦ ⎣i r ⎦ ⎣ Lm e − jθ Lr ⎦ ⎣i r ⎦
24
Gde su:
Lsσ -trofazna rasipna induktivnost statora.
Lrσ - svedena vrednost trofazne rasipne induktivnosti rotora na stator.
Lm - trofazna induktivnost magnetiziranja.
Ls - ukupna trofazna induktivnost statora ( Ls = Lsσ + Lm )
Lr -ukupna trofazna induktivnost rotora ( Lr = Lrσ + Lm )
Iz gornjeg izraza se vidi da vektori fluksnih obuhvata se menjaju
proporcionalno sa vektorima struje statora i rotora.
⎡u s ⎤ ⎡ Rs 0 ⎤ ⎡i s ⎤ d ⎡ψ s ⎤
⎢u ⎥ = ⎢ 0 + ⎢ ⎥
Rr ⎥⎦ ⎢⎣i r ⎥⎦ dt ⎣⎢ψ r ⎦⎥
(3.4-1)
⎣ r⎦ ⎣
Gde su:
Rs-otpornost statorskih namotaja po fazama,
Rr-svedena otpornost rotorskih namotaja po fazama.
25
4. PROSTORNI VEKTORI I JEDNAČINE U
ZAJEDNIČKOM OPŠTEM KOORDINATNOM SISTEMU
Im(S)
Im(R)
Im(K) Re(K) ωK
Ir
αs αr Re(R) ω
Is
θr
θK
θ Re(S)
Sl. 4-1 Transformacija vektora struje rotora iz prirodnog rotorskog i vektora struje
statora iz prirodnog statorskog koordinatnog sistema u opšti obrtni koordinatni sistem.
Pre transformacije treba odrediti izraz ugla za kretanje realne ose opšteg
zajedničkog koordinatnog sistema u odnosu na realnu osu nepokretnog koordinatnog
sistema. Ovo ugaono zaokretanje ima vrednost:
θ k = θ k ( 0 ) + ∫ ω k dt (4-1)
Gde su:
ωk - ugaona brzina opšteg koordinatnog sistema.
θk - ugaono zakretanje realne ose zajedničkog opšteg koordinatnog sistema u
odnosu na realnu osu statorskog prirodnog koordinatnog sistema.
θ k ( 0 ) - početno ugaono zakretanje realne ose zajedničkog opšteg koordinatnog
sistema.
26
4.1 Transformacija vektora iz prirodnih koordinatnih sistema u
zajednički opšti (K) koordinatni sistem
Ugao između realne ose prirodnog statorskog (S) i realne ose opšteg
zajedničkog (K) koordinatnog sistema je θ k . To znači da prostorne vektore statora pri
tranformaciji iz prirodnog statorskog u zajednički opšti koordinatni sistem treba
množiti sa e − jθ . Dakle:
i sk = i s e − jθ k
u sk = u s e − jθ k (4.1-1)
ψ sk = ψ s e − jθ k
Gde su:
i sk - prostorni vektor statorskih struja u opštem zajedničkom koordinatnom
sistemu.
u sk - prostorni vektor statorskih napona u opštem zajedničkom koordinatnom
sistemu.
ψ sk - prostorni vektor statorskih fluksnih obuhvata u opštem zajedničkom
koordinatnom sistemu.
Ugaono zakretanje realne ose zajedničkog opšteg (K) koordinatnog sistema u
odnosu na realnu osu rotorskog prirodnog (R) kordinatnog sistema ( θ r ) je:
θr = θk −θ (4.1-2)
i rk = i r e jθ r = i r e j (θ r −θ )
u rk = u r e jθ r = u r e j (θ r −θ ) (4.1-3)
ψ rk = ψ r e jθ = ψ r e j (θ
r r −θ )
Gde su:
i rk - prostorni vektor rotorskih struja u opštem zajedničkom koordinatnom
sistemu.
u rk - prostorni vektor rotorskih napona u opštem zajedničkom koordinatnom
sistemu.
ψ rk - prostorni vektor rotorskih fluksnih obuhvata u opštem zajedničkom
koordinatnom sistemu.
Napomena: podrazumeva se da ukoliko zajednički opšti koordinatni sistem(K)
se odabira tako da istovremeno odgovara statorskom prirodnom koordinatnom
sistemu(S), tada u ovaj zajednički koordinatni sistem treba transformisati samo
27
rotorske prostorne vektore. U obrnutom slučaju, kada se zajednički opšti koordinatni
sistem (K) odabira tako da istovremeno odgovara prirodnom rotorskom koordinatnom
sistemu (R), onda u ovaj zajednički obrtni koordinatni sistem treba da se transformišu
samo statorski prostorni vektori.
⎡ψ sk ⎤ ⎡ Lsσ + Lm Lm ⎤ ⎡i sk ⎤ ⎡ Ls Lm ⎤ ⎡i sk ⎤
⎢ ⎥=⎢ = (4.2-1)
⎢⎣ψ rk ⎥⎦ ⎣ Lm Lsσ + Lm ⎥⎦ ⎢⎣i rk ⎥⎦ ⎢⎣ Lm Lr ⎥⎦ ⎢⎣i rk ⎥⎦
⎡u sk ⎤ ⎡ Rs 0 ⎤ ⎡i sk ⎤ d ⎡ψ sk ⎤ ⎡ jω k ψ sk ⎤
⎢u ⎥ = ⎢ 0 ⎥ ⎢ ⎥ + ⎢ ⎥+⎢ ⎥ (4.3-2)
⎣ rk ⎦ ⎣ Rr ⎦ ⎣i rk ⎦ dt ⎣⎢ψ rk ⎦⎥ ⎣⎢ j (ω k − ω )ψ rk ⎦⎥
⎡u sk ⎤ ⎡ Rs 0 ⎤ ⎡i sk ⎤ ⎡ Lsσ + Lm Lm ⎤ d ⎡i sk ⎤
⎢u ⎥ = ⎢ 0 + +
⎣ rk ⎦ ⎣ Rr ⎥⎦ ⎢⎣i rk ⎥⎦ ⎢⎣ Lm Lsσ + Lm ⎥⎦ dt ⎢⎣i rk ⎥⎦
(4.3-3)
⎡ jω 0 ⎤ ⎡ Lsσ + Lm Lm ⎤ ⎡i sk ⎤
+⎢ k
⎣ 0 j (ωk − ω )⎥⎦ ⎢⎣ Lm Lsσ + Lm ⎥⎦ ⎢⎣i rk ⎥⎦
28
Polazeći od sistema naponskih jednačina (4.3-3) za razmatranje prelaznih
režima trofazne mašine može se nacrtati opšta ekvivalentna šema koja je prikazana
na slici 4.3-1.
imk
usk Lm urk
Sl. 4.3-1 Opšta ekvivalentna šema za analizu rotacionih električnih mašina na osnovu
naponskih jednačina u opštem koordinatnom sistemu
i mk = i sk + i rk (4.3-4)
v k = v dk + j ⋅ v qk (4.4-1)
u sk = u sdk + j ⋅ u sqk
i sk = i sdk + j ⋅ i sqk
ψ sk = ψ sdk + j ⋅ψ sqk
u rk = u rdk + j ⋅ u rqk (4.4-2)
i rk = irdk + j ⋅ irqk
ψ rk = ψ rdk + j ⋅ψ rqk
Gde su:
u sdk , u sqk - skalarne komponente statorskih napona u opštem zajedničkom
koordinatnom sistemu.
29
i sdk , i sqk - skalarne komponente statorskih struja u opštem zajedničkom
koordinatnom sistemu.
ψ sdk ,ψ sqk - skalarne komponente statorskih fluksnih obuhvata statora u opštem
zajedničkom koordinatnom sistemu.
u rdk , u rqk - skalarne komponente rotorskih napona u opštem zajedničkom
koordinatnom sistemu.
irdk , irqk - skalarne komponente rotorskih struja u opštem zajedničkom
koordinatnom sistemu.
ψ rdk ,ψ rqk - skalarne komponente rotorskih fluksnih obuhvata statora u opštem
zajedničkom koordinatnom sistemu.
Ako u sistemu vektorskih naponskih diferencijalnih jednačina (4.3-2),
odgovarajuće vektore zamenimo sa svojim skalarnim komponentima, vektorska
diferencijalna jednačina će se rasprezati u dve skalarne diferencijane jednačine, kao
što sledi:
30
ωk ψsqk (ωk-ω)ψrqk
isdk Rs Lsσ Rr Lrσ irdk
imdk
Lm
usdk urdk
imqk
Lm
usqk urqk
b.)
Sl. 4.4-1 Opšte ekvivalentne šeme za analizu trofaznih rotacionih električnih mašina
uz pomoć sistema skalarnih naponskih jednačina u opštem koordinatnom sistemu
i s = i sk e jθ k
(4.5-1)
u s = u sk e jθ k
i r = i rk e − jθ r = i rk e − j (θ r −θ )
(4.5-2)
u r = u rk e − jθ r = u rk e − j (θ r −θ )
31
Rasprezanje prostornih vektora u trenutne vrednosti po fazana može se
sprovesti samo onda, ako se poznaju i njihove nulte komponente uso ,uro, iso, iro, koje u
simetričnim prelaznim režimima uvek imaju vrednost nule. U onim nesimetričnim
režimima, u kojima su vrednosti nultih komponenata različiti su od nule, njihove
vrednosti se određuju posebnim sistemom nultih diferencijalnih jednačina.
Način rasprezanje prostornih vektora statora iz prirodnog statorskog
koordinatnog sistema u trenutne vrednosti po fazama se mogu sprovesti uz pomoć
sledećih jednačina:
u a = Re(u s ) + u so
u b = Re(u s ⋅ a 2 ) + u so (4.5-3)
u c = Re(u s ⋅ a ) + u so
ia = Re(i s ) + i so
( )
ib = Re i s ⋅ a 2 + i so (4.5-4)
ic = Re(i s ⋅ a ) + i so
Gde su:
u so - trenutna vrednost nulte komponente statorskih napona,
iso - trenutna vrednost nulte komponente statorskih struja.
Jednačine za rasprezanje prostornih vektora rotora iz rotorskog prirodnog
koordinatnog sistema u svedene trenutne vrednosti po fazama su sledeće:
u ra = Re(u r ) + u ro
( )
u rb = Re u r ⋅ a 2 + u ro (4.5-5)
u rc = Re(u r ⋅ a ) + u ro
Gde su:
uro - trenutna vrednost nulte komponente rotorskih napona,
iro - trenutna vrednost nulte komponente rotorskih struja.
1
u so = (u a + ub + u c ) (4.5-7)
3
1
i so = (ia + ib + ic ) (4.5-8)
3
32
1
u ro = (u ra + u rb + u rc ) (4.5-9)
3
1
iro = (ira + irb + irc ) (4.5-10)
3
33
5 NAČIN SIMULACIJE UTICAJA GUBITAKA SNAGE U
GVOŽĐU STATORA
PFe ~ B 2 ~ e 2 (5-1)
Gde su:
PFe - gubici u gvožđu statora
B - indukcija
e - trenutna vrednost indukovanog napona.
dψ mk
e mk = jωkψ mk + (5-2)
dt
Gde su:
e mk - vektor indukovanog napona,
ψ mk - vektor fluksnog obuhvata magetiziranja .
Treba ovde naglasiti da otpornost gubitaka u gvožđu, Rm u ekvivalentnim
šemama za analizu prelaznih režima se određuje na isti način kao što je to do sada bilo
uobičajeno u ekvivalentnim šemama za analizu trofazne mašine u ustaljenim
režimima.
34
5.1 Opšti sistem vektorskih naponskih diferencijalnih
jednačina sa otporom gubitaka u gvožđu
⎡u sk ⎤ ⎡ Rs 0 0 ⎤ ⎡ i sk ⎤ ⎡ψ + ψ ⎤ ⎡ jω k ψ + ψ ( ) ⎤
d ⎢ sσk
( )
sσk
⎢u ⎥ = ⎢ 0 ⎥ ⎢ ⎥
mk
⎥ ⎢ mk
⎥
⎢ rk ⎥ ⎢ Rr 0 ⎥ ⎢ i rk ⎥ + ⎢ψ rσk + ψ mk ⎥ + ⎢ j (ω k − ω ) ψ rσk + ψ mk ⎥ (5.1-1)
dt ⎢ ⎥ ⎢ ⎥
⎢⎣ 0 ⎥⎦ ⎢⎣− Rm − Rm Rm ⎥⎦ ⎢⎣i mk ⎥⎦ ⎣ ψ mk ⎦ ⎣ jω k ψ mk ⎦
Gde su:
ψ sσk - rasipni fluksni obuhvat statora,
ψ rσk - rasipni fluksni obuhvat rotora,
Rm - otpornost gubitaka u gvožđu.
⎡u sk ⎤ ⎡ Rs + Rm Rm − Rm ⎤ ⎡ i sk ⎤ ⎡ Lsσ i sk ⎤
d ⎢
⎢u ⎥ = ⎢ R
⎢ rk ⎥ ⎢ m Rr + Rm − Rm ⎥ ⎢ i rk ⎥ + ⎢ Lrσ i rk ⎥⎥
⎥ ⎢ ⎥
dt
⎣⎢ 0 ⎦⎥ ⎣⎢ − Rm − Rm Rm ⎦⎥ ⎣⎢i mk ⎦⎥ ⎢⎣ Lm i mk ⎥⎦
(5.1-2)
⎡ jω k Lsσ i sk ⎤
+ ⎢ j ((ω k − ω )Lrσ i rk − ωLm i mk )⎥⎥
⎢
⎢⎣ jω k Lm i mk ⎥⎦
35
jωkψsσk jωkψmk j(ωk-ω)ψrk
isk Lsσ irk
Rs Rr Lrσ
imk
iFek ik
Lm urk
usk Rm
i k = i sk − i Fek (5.1-3)
i mk = i k + i rk (5.1-4)
di sdk
u sdk = Rs i sdk + Lsσ + Rm i Fedk − ω k Lsσ i sqk
dt
di sqk
u sqk = Rs i sqk + Lsσ + Rm i Feqk + ω k Lsσ i sdk
dt
dirdk
u rdk = Rr irdk + Lrσ + Rm i Fedk − (ω k − ω )Lrσ irqk + ωLm imqk
dt
(5.2-1)
dirqk
u rqk = Rr irqk + Lrσ + Rm i Feqk + (ω k − ω )Lrσ irdk − ωLm imdk
dt
d i mdk
0 = Lm + Rm i Fedk − ω k Lm imqk
dt
d i mqk
0 = Lm + Rm i Feqk + ω k Lm imdk
dt
36
Gde su:
i Fedk , i Feqk - skalarne komponente struje gubitaka u gvožđu.
imdk
iFedk idk
usdk Rm Lm urdk
a.)
ωk Lsσ isdk ωk Lm imdk (ωk-ω)(Lrσ irdk+ L m imdk)
isqk
Rs Lsσ Rr Lrσ irqk
iFeqk imqk
iqk
usqk Rm Lm urqk
b.)
Sl. 5.2-1 Opšte skalarne ekvivalentne šeme za simulaciju trofazne mašine uzimajući u
obzir gubitke snage u gvožđu.
37
5.3 Trenutne snage i trenutni gubici snage
p1 =
3
2
( ∗ ∗
Re u sk i sk + u rk i rk )
3
(
p1 = Re u sdk i sdk + u sqk i sqk + u rdk irdk + u rqk irqk
2
) (5.3-1)
3 ∗
p cus = Rs i sk i sk
2
p cus =
3
2
2
(
Rs i sdk + i sqk
2
) (5.3-2)
3 ∗
p cur = Rr i rk i rk
2
p cur =
3
2
2
(
Rr irdk + irqk
2
) (5.3-3)
3 ∗
p Fes = Rm i Fek i Fek
2
p Fes =
3
2
2
(
Rm i Fedk + i Feqk
2
) (5.3-4)
pm =
3
2
∗
Lmω Im i k i mk ( )
pm =
3
2
(
Lmω imdk iqk − imqk idk ) (5.3-5)
38
Trenutne vrednosti gubitaka snage usled akumulacije na induktivnost rasipanja
statora su:
3 ⎛⎜ dψ sσk ∗ ⎞⎟
p sσ a = Re i sk ⎟
2 ⎜⎝ dt ⎠
3⎛ dψ sσdk dψ sσqk ⎞
p sσ a = ⎜⎜ i sdk + i sqk ⎟⎟ (5.3-6)
2⎝ dt dt ⎠
3 ⎛⎜ dψ rσk ∗ ⎞⎟
p rσa = Re i rk ⎟
2 ⎜⎝ dt ⎠
3 ⎛ dψ rσdk dψ rσqk ⎞
prσa = ⎜⎜ irdk + irqk ⎟⎟ (5.3-7)
2⎝ dt dt ⎠
3 ⎛⎜ dψ mk ∗ ⎞⎟
p ma = Re i mk ⎟
2 ⎜⎝ dt ⎠
3⎛ dψ mdk dψ mqk ⎞
pma = ⎜⎜ imdk + imqk ⎟⎟ (5.3-8)
2⎝ dt dt ⎠
me =
3
2
(
p Im ψ mk i k
*
)
me =
3
2
*
(
pLm Im i mk i k ) (5.4-1)
mm = me − mtrv (5.4-2)
39
5.5 Skalarne naponske diferencijalne jednačine sinhronog
motora sa izraženim polovima u zajedničkom rotorskom
koordinatnom sistemu
di sd
u sd = R s i sd + Lsσ + Rm i Fed − ωLsσ i sq
dt
di sq
u sq = R s i sq + Lsσ + Rm i Feq + ωLsσ i sd
dt
di f
u f = R f i f + L fσ + Rm i Fed + ωLmq imq
dt
di
0 = R Dd i Dd + LDσd Dd + Rm i Fed + ωLmq i mq (5.5-1)
dt
di Dq
0 = R Dq i Dq + LDσq + Rm i Feq − ωLmd imd
dt
di
0 = Lmd md + Rm i Fed − ωLmq imq
dt
d i mq
0 = Lmq + Rm i Feq + ωLmd imd
dt
Gde su:
u sd , u sq -skalarne komponente statorskog napona.
i sd , isq - skalarne komponente statorske struje.
imd , imq - skalarne komponente struje magnetiziranje.
i Fed , i Feq - skalarne komponente struje gubitaka u gvožđu statora.
id , iq - skalarne komponente struje statora bez komponenata struje gubitaka u
gvožđu.
u f - napon pobudnog namotaja svedena na statorsku stranu.
R f - otpornosti pobudnog namotaja svedena na statorsku stranu.
i f - struja pobudnog namotaja svedena na statorsku stranu.
L fσ - rasipna induktivnost pobudnog namotaja svedena na statorsku stranu.
R Dd , RDq - otpornosti prigušnog kaveza u uzdužnom i poprečnom smeru
svedeno na stator.
40
i Dd , i Dq - skalarne komponente struje prigušnog kaveza svedene na statorsku
stranu.
LDσd , LDσq - rasipna induktivnost prigušnog kaveza u uzdužnom i poprečnom
smeru svedeno na stator.
Lmd , Lmq - magnetizirajuća induktivnost u uzdužnom i poprečnom smeru.
iFed imd uf
id
usd Rm Lmd
a.)
ω Lsσ isd ω Lmd imd
isq
Rs Lsσ RDq LDσq iDq
iFeq imq
iq
usq Rm Lmq
b.)
Sl. 5.5-1 Ekvivalentne šeme skalarnih komponenata za analizu gubitaka u gvožđu
statora rotacionih električnih mašina na osnovu naponske jednačine skalarnih
komponenata u opštem kordinatnom sistemu
41
Trenutna vrednost momenta na vratilu motora dobije se ako od trenutne
vrednosti proizvedog momenta odbija moment trenja i ventilacije mašine:
mm = me − mtrv (5.6-2)
Gde su:
Ω - mehanička ugaona brzina,
J Σ -zbir momenta inercije motora i radne mašine.
Između električne i mehaničke ugaone brzine postoji sledeća veza:
ω = pΩ (5.7-2)
dω
JΣ = pmm (5.7-3)
dt
42
6. USTALJENI REŽIM SINHRONOG MOTORA
Pri simulaciji sinhronog motora numeričkim metodama u vremenskim
funkcijama struja i momenta pojavljavljuju se pulsacione komponente, koje otežavaju
određivanje srednje vrednosti momenta i snage. Ova mana se može eliminisati
korišćenjem kompleksnih jednačina, koje se izvode iz sistema diferencijalnih
jednačina za simulaciju rada u prelaznom režimu. Pri izvođenju kompleksnih
jednačina iz diferencijalnih jednačina, za ustaljeni režim, struje treba zameniti
njihovim kompleksnim irazima:
v ⇒V (6-1)
∂v
⇒ jsω1V (6-2)
∂t
Gde je:
s - klizanje rotora.
To znači da se izvod može zameniti množenjem sa članom jsω1 .
U sd = U
(6.1-1)
U sq = − jU
Gde je:
U- efektivna vrednost napona.
Na osnovu navedenih pravila iz diferencijalnih jednačina (5.5-1) se dobijaju
sledeće kompleksne jednačine:
43
⎛U sd ⎞ ⎛ Z 11 Z 12 Z 13 Z 14 Z 15 Z 16 Z 17 ⎞⎛ I sd ⎞
⎜ ⎟ ⎜ ⎟⎜ ⎟
⎜ U sq ⎟ ⎜ Z 21 Z 22 Z 23 Z 24 Z 25 Z 26 Z 27 ⎟⎜ I sq ⎟
⎜ 0 ⎟ ⎜Z ⎜ ⎟
Z 32 Z 33 Z 34 Z 35 Z 36 Z 37 ⎟⎟⎜ I Dd ⎟
⎜ ⎟ ⎜ 31
⎜ 0 ⎟ = ⎜ Z 41 Z 42 Z 43 Z 44 Z 45 Z 46 Z 47 ⎟⎜ I Dq ⎟ (6.1-2)
⎜ ⎟ ⎜ ⎟⎜ ⎟
⎜ U f ⎟ ⎜ Z 51 Z 52 Z 53 Z 54 Z 55 Z 56 Z 57 ⎟⎜ I f ⎟
⎜ 0 ⎟ ⎜ Z 61 Z 62 Z 63 Z 64 Z 65 Z 66 Z 67 ⎟⎜ I md ⎟
⎜ ⎟ ⎜⎜ ⎟⎜ ⎟
⎝ 0 ⎠ ⎝ Z 71 Z 72 Z 73 Z 74 Z 75 Z 76 Z 77 ⎟⎠⎜⎝ I mq ⎟⎠
Gde su:
Z 11 = Z 22 = R s + RV + Rm + js ( X sσ + X V )
Z 33 = R Dd + Rm + jsX Dσd
Z 44 = R Dq + Rm + jsX Dσq
Z 55 = R f + R z + Rm + jsX fσ (6.1-3)
Z 66 = Rm + jsX md
Z 77 = Rm + jsX mq
Gde su:
X V - predimpenansa,
Rz - zaštitni otpornik sveden na statorsku stranu.
X fσ - rasipna reaktansa pobudnog namotaja svedena na statorsku stranu.
X Dσd , X Dσq - rasipne reaktanse prigušnog kaveza u uzdužnom i poprečnom
smeru, svedena na statorsku stranu.
X md , X mq - magnetizirajuće reaktanse u uzdužnom i poprečnom smeru.
44
Vrednosti međusobnih impedansa su:
Z 12 = −(1 − s )X sσ
Z 13 = Z 15 = Z 24 = Z 31 = Z 35 = Z 42 = Z 51 = Z 53 = Rm
Z 16 = Z 27 = Z 36 = Z 47 = Z 56 = Z 61 = Z 63 = Z 65 = Z 72 = Z 74 = − Rm
(6.1-4)
Z 21 = (1 − s )X sσ
Z 37 = Z 57 = − Z 67 = (1 − s )X mq
Z 46 = − Z 76 = −(1 − s ) X md
s(Xsσ+Xv) Imd RV
IFed
Usd Rm sXmd
b.)
Sl. 6.1-1 Ekvivalentne šeme sinhronog motora u asinhronom režimu u rotorskom
koordinatnom sistemu
I Fed = I sd + I f + I rd − I md
(6.1-5)
I Feq = I sq + I rq − I mq
Zbog kasnijih proračuna snaga potrebno je uočiti razliku između struje statora i
struja gubitaka u gvožđu Id i Iq:
I d = I sd − I Fed
(6.1-6)
I q = I sq − I Feq
45
Kao što se vidi u ekvivalentnoj šemi za osu d pojavljuju se komponente q struja
i obrnuto, to znači da su smerovi d i q međusobno povezani preko magnetnog polja,
čiji je uticaj modeliran pomoću naponskih generatora. Veličina tog uticaja zavisi od
klizanja, i proporcionalna je sa brzinom rotora.
( *
Ps = 3 Re U sd I sd + U sq I sq
*
) (6.1-7)
( *
P2 = 3(1 − s ) Re X md I md I q − X mq I mq I d
*
) (6.1-8)
Pm = P2 − Ptrv (6.1-9)
Gde su:
Pm -odata mehanička snaga na vratilu motora:
Ptrv -gubici trenja i ventilacije.
( *
Pcus = 3Rs I sd I sd + I sq I sq
*
) (6.1-10)
(
PFes = 3Rm I Fed I Fed + I Feq I Feq
∗ ∗
) (6.1-11)
( *
PcuD = 3 RDd I rd I rd + RDq I rq I rq
*
) (6.1-12)
*
Pcuf = 3R f I f I f (6.1-13)
*
Pz = 3R z I f I f (6.1-14)
46
6.1.2 Bilans reaktivne snage
( *
Qs = 3 Im U sd I sd + U sq I sq
*
) (6.1-15)
( *
Qsσ = 3 X sσ I sd I sd + I sq I sq
*
) (6.1-16)
( *
QD = 3 X Dσd I rd I rd + X Dσq I rq I rq
*
) (6.1-17)
*
Q fσ = 3 X fσ I f I f (6.1-18)
( *
Qm = 3 X md I md I md + X mq I mq I mq
*
) (6.1-19)
Me = 3
ω1
p
( *
Re X md I md I q − X mq I mq I d
*
) (6.1-20)
Gde je:
I d = I md − I rd − I f i I q = I mq − I rq (6.1-21)
47
Izraz (6.1-20) poprima sledeći oblik:
(
⎛ (X md − X mq )Re I md I mq * +
p ) ⎞
M e = 3 Re⎜ ⎟
( )
(6.1-22)
ω1 ⎜ Re X mq I mq (I rd + I f )* − X md I md I rq * ⎟
⎝ ⎠
Iz izraza (6.2-22) se vidi da se moment može podeliti na dva dela iz kojih prvi
predstavlja reluktantni moment, dok drugi je posledica interakcije fluksa i struje.
Može se slično postupiti kao kod definicije odate mahaničke snage. Proizvedeni
električni moment treba smanjiti sa momentom trenja i ventilacije, radi dobijanja
odatog mehaničkog momenta:
M m = M e − M trv (6.1-23)
Gde su.
M m - mehanički moment na vratilu motora,
M trv -moment gubitaka trenja i ventilacije.
U sd = U cos(γ )
(6.2-1)
U sq = U sin(γ )
Gde je:
γ -ugao između prostornog vektora napona i osa d koordinatnog sistema.
⎛U sd ⎞ ⎛ Z 11 Z 12 Z 13 Z 14 Z 15 ⎞⎛ I sd ⎞
⎜ ⎟ ⎜ ⎟⎜ ⎟
⎜ U sq ⎟ ⎜ Z 21 Z 22 Z 23 Z 24 Z 25 ⎟⎜ I sq ⎟
⎜U ⎟ = ⎜Z ⎜ ⎟
Z 32 Z 33 Z 34 Z 35 ⎟⎜ I f ⎟ (6.2-2)
⎜ f ⎟ ⎜ 31 ⎟
⎜ 0 ⎟ ⎜ Z 41 Z 42 Z 43 Z 44 Z 45 ⎟⎜ I md ⎟
⎜ ⎟ ⎜ ⎟⎜ ⎟
⎝ 0 ⎠ ⎝ Z 51 Z 52 Z 53 Z 54 Z 55 ⎠⎜⎝ I mq ⎟⎠
Gde su:
Z 11 , Z 22 , Z 33 , Z 44 , Z 55 sopstvene impedanse,
Z 12 , Z 13 , Z 14 ,......., Z 54 međusobne impedanse
48
Sopstvene impedanse imaju sledeće vrednosti :
Z 11 = Z 22 = Rs + Rm
Z 33 = R f + Rm (6.2-3)
Z 44 = Rm
Z 55 = Rm
Z 12 = − X sσ
Z 13 = Z 31 = Rm
Z 14 = Z 25 = Z 34 = Z 41 = Z 43 = Z 52 = − Rm
(6.2-4)
Z 21 = X sσ
Z 35 = − Z 45 = X mq
Z 54 = X md
XsσIsq X mqImq
Isd Rs Id If
Rf
IFed Imd
Usd Rm Uf
a.)
Isq XsσIsd Iq X mdImd
Rs
IFeq Imq
Usq Rm
b.)
Sl. 6.2-1 Ekvivalentne šeme sinhronog motora u sinhronom režimu u rotorskom
koordinatnom sistemu
I Fed = I sd + I f − I md
(6.2-5)
I Feq = I sq − I mq
49
Dok komponenti struja Id i Iq imaju sledeće vrednosti:
I d = I sd − I Fed
(6.2-6)
I q = I mq
U sinhronom režimu primljena snaga motora se sastoji iz dva dela, koji su:
Primljena snaga statora:
( *
Ps = 3 Re U sd I sd + U sq I sq
*
) (6.2-7)
( *
P2 = 3 Re X md I md I q − X mq I mq I d
*
) (6.2-9)
( *
Pcus = 3Rs I sd I sd + I sq I sq
*
) (6.2-11)
( ∗
PFes = 3Rm I Fed I Fed + I Feq I Feq
∗
) (6.2-12)
( *
Qs = 3 Im U sd I sd + U sq I sq
*
) (6.2-14)
50
Reaktivna snaga na reaktansi rasipanja statora je:
( *
Qsσ = 3 X sσ I sd I sd + I sq I sq
*
) (6.2-15)
( *
Qm = 3 X md I md I md + X mq I mq I mq
*
) (6.2-16)
Mm = 3
p
ω1
( *
Re X md I md I q − X mq I mq I d
*
) (6.2-17)
I d = I md − I f i I q = I mq
Mm = 3
p
ω1
((X md ( *
)
− X mq )Re I md I mq + Re X mq I mq I f ( *
)) (6.2-18)
Iz izraza (6.2-18) se vidi da se moment može podeliti na dva dela iz kojih prvi
predstavlja reluktantni moment, dok drugi deo je posledica interakcije fluksa i struje.
Slično kao kod definicije odate mehaničke snage, proizvedeni električni moment
treba smanjiti sa momentom trenja i ventilacije, radi dobijanja odatog mehaničkog
momenta:
M m = M e − M trv (6.1-19)
Gde su.
M m - mehanički moment na vratilu motora:
M trv -moment gubitaka trenja i ventilacije.
51
7. SIMULACIJE SINHRONIH MOTORA SA IZRAŽENIM
POLOVIMA U PRELAZNIM REŽIMIMA
Ostali parametri:
• koeficijent svođenja struje pobudnog namotaja na stator:
K i = m 2 N sξ s 2 N f ξ f K i = 0.152675
• koeficijent svođenja napona pobudnog namotaja na stator:
2
K u = 2 N sξ s N f ξ f Ku = K i = 0.107833
3
• koeficijent svođenja otpornosti pobudnog namotaja na stator
K r = K u K i = m ( N s ξ s ) 2 2( N f ξ f ) 2 K r = K u K i = 0.01554
• otpornost statorskih namotaja po fazi: Rs = 1.45 Ω
• svedena vrednost otpornosti kaveza u smeru d: R Dd = 34.813 Ω
• svedena vrednost otpornosti kaveza u smeru q: R Dq = 158.965 Ω
• otpornost pobudnog namotaja: R p = 30 Ω
• svedena otpornost pobudnog namotaja: R f = K r R p = 0.466196 Ω
• trofazna reaktansa rasipanja statora po fazi: X sσ = 5.074 Ω
• trofazna svedena vrednost reaktanse rasipanja kaveza u smeru d:
X Dσd = 50.413 Ω
52
• trofazna svedena vrednost reaktanse rasipanja kaveza u smeru q:
X Dσq = 55.131 Ω
• svedena vrednost reaktanse pobudnog namotaja:
X fσ = K r X pσ = 0.06749 Ω
• reaktansa magnećenje u uzdužnom smeru: X md = 60.731 Ω
• reaktansa magnećenje u poprečnom smeru: X mq = 50.609 Ω
u sd = Uˆ cos(ω1t − θ k )
(7-1)
u = Uˆ sin (ω t − θ )
sq 1 k
53
7.1 Asinhroni zalet sinhronog motora
isd[A] isq[A]
10 10
5 5
0 0
-5 -5
t[s] t[s]
-10 -100
0 0.2 0.4 0.6 0.8 1 0.2 0.4 0.6 0.8 1
54
ω[s-1] M[Nm]
180
20
120
10
60
0
t[s] ω[s-1]
0 -10
0 0.2 0.4 0.6 0.8 1 -50 0 50 100 150 200
a.) b.)
Sl. 7.1-2 Promene ugaone brzine (a.) i momenta (b.) toku zaleta
ep[V]
3000
1500
-1500
t[s]
-3000
0 0.2 0.4 0.6 0.8 1
Sl. 7.1-3 Vrednost indukovanog napona u pobudnom namotaju u toku zaleta
ia[A]
10
-5
t[s]
-10
0 0.2 0.4 0.6 0.8 1
Sl. 7.1-4 Promene struje jedne faze u toku zaleta
55
7.1.2 Asinhroni zalet sinhronog motora sa kratkospojenim pobudnim
namotajem bez predimpedansa
Pobudni namotaj je kratkospojen, i stator direktno priključeni na energetsku
mrežu. To znači da struju pobudnog namotaja ograičava omska otpornost i impedansa
rasipnog induktiviteta. Pri zaletu, struje statora i rotora su velike zbog kratkospajanog
pobudnog namotaja, što može dovesti do pregorevanja namotaja.
isd[A] isq[A]
50 12.2
40
30
20 6.6
10
0 0
-10
-20
-30 -6.6
-40 t[s] t[s]
-500 -12.2
0.25 0.5 0.75 1 1.25 0 0.25 0.5 0.75 1 1.25
Sl. 7.1-5 Promene komponenata d i q statorske struje u toku zaleta
ω[s-1] M[Nm]
180 200
120 100
60 0
25
-25
t[s]
-50
0 0.25 0.5 0.75 1 1.25
Sl. 7.1-7 Promene struje prve faze u toku zaleta
56
if[A]
50
40
30
20
10
0
-10
-20
-30
-40 t[s]
-50
0 0.25 0.5 0.75 1 1.25
Sl. 7.1-8 Promene struje pobudnog namotaja u toku zaleta
Na slici 7.1-6 b.) se vidi da se rotor ubrzava do polovine sinhrone brzine, gde se
nalazi duboko sedlo u momentnoj karakteristici, što je rezultat asimetrije otpornosti
rotora i induktivnosti magnećenja u smerovima d i q. Uticaj asimetrije komponenata
rotorskih otpornosti na struje se vidi na slici 7.1-7. Na obliku struje se vidi da pored
frekvencije mreže sadržava drugu vrstu harmonika, čija frekvencija se menja sa
brzinom rotora, i proporcionalna je sa klizanjem. Kraj vektora struje statora u
sinhronom koordinatnom sistemu u ustaljenom režimu kreće se na elipsi kao što je
prikazano na slici 7.1-9.
-5
Is sω1
-10
isx[A]
-15
0 5 10 15
Sl. 7.1-9 Kretanja vektora struje statora u sinhronom koordinatnom sistemu u
ustaljenom režimu
57
Lsσ
disd
dt
1 ⎛ ω ⎞
(
− ω r Lsσ isq = − Lsσ ω1 sin⎜ t 1 ⎟ Î sd + Î sq
2
) (7.1-1)
⎝ 2 ⎠
Lsσ
disq
dt
1 ⎛ ω ⎞
(
+ ω r Lsσ isd = Lsσ ω1 cos⎜ t 1 ⎟ Iˆsd + Iˆsq
2
) (7.1-2)
⎝ 2⎠
u gd (t ) =
2
ω1 ⎛ ω ⎞
(
sin ⎜ t 1 ⎟ Iˆmd Lmd + Iˆmq Lmq )
⎝ 2 ⎠
(7.1-3)
ω ⎛ ω ⎞
(
u gq (t ) = − 1 cos⎜ t 1 ⎟ Iˆmd Lmd + Iˆmq Lmq
2
)
⎝ 2 ⎠
isd[A] isq[A]
15 15
10 10
5 5
0 0
-5 -5
-10 -10
t[s] t[s]
-15 -15
0 0.4 0.8
1.2 1.6 2.0 0
0.4 0.8 1.2 1.6 2.0
a.) b.)
Sl. 7.1-10 Promene komponenata d i q statorske struje u toku zaleta sa
predimpedansom.
58
Promene brzine i momenta u toku zaleta je prikazana na slici 7.1-11:
ω[s-1] M[Nm]
160 30
20
120
10
80 0
40 -10
-5
-10
t[s]
-15
0 0.3 0.6 0.9 1.2 1.5
Sl. 7.1-12 Promene struje prve faze u toku zaleta
isd[A]
15
10
5
0
-5
-10
t[s]
-15
0 0.4 0.8 1.2 1.6 2.0
Sl. 7.1-13 Promene struje pobudnog namotaja u toku zaleta
59
7.1.4 Asinhroni zalet sinhronog motora sa zaštitnom otpornikom bez
predimpedansa
Struju pobudnog namotaja ograničava zaštitni otpornik, a namotaji statora su
direktno priključeni na energetsku mrežu. Zaštitni otpornik pored struje pobudnog
namotaja ograničava i struju statora. Sa povećanjem otpornosti u kolu pobudnog
namotaja smanjuje se asimetrija otpornosti rotora, što smanjuje sedlo momentne
karakteristike (u analiziranom slučaju vrednost zaštitnog otpornika je četrideset puta
veća od otpornosti pobudnog namotaja).
Promene komponenata d i q struje statora u toku zaleta sinhronog motora su
prikazani na slikama 7.1-14. a.) i b.).
isd[A] isq[A]
20 20
15 15
10 10
5 5
0 0
-5 -5
-10 -10
-15 t[s] -15 t[s]
-20 -20
0 0.4 0.8 1.2 1.6 2.0 0 0.4 0.8 1.2 1.6 2.0
a.) b.)
Sl. 7.1-14 Promene komponenata d i q statorske struje u toku zaleta.
Upoređenjem slike 7.1-10. a.) , b.) i 7.1-14. a.) i b.) može se videti da polaznu
struju u istoj meri ograničavaju žaštitni otpornik i predimpedansa, dok u slučaju zaleta
sa zaštitnom otpornikom sedlo momenta se smanjuje, šta omogućava zaleta iznad
polovine sinhrone brzine, kao što je prikazano na slikama 7.1-15 a.) i b.).
ω[s-1] M[Nm]
300 80
240 60
180 40
120 20
60 0
t[s] ω[s-1]
0 -20
0 0.4 0.8 1.2 1.6 2.0 -50 0 100 200 300
a.) b.)
Sl. 7.1-15 Promene ugaone brzine (a.) i momenta (b.) u toku zaleta.
Upoređenjem momentnih karakteristika sa slika 7.1-6 b.), 7.1-11 b.) i 7.1-15 b.)
se vidi da bez zaštitnog otpornika kod polovine sinhrone brzine srednja vrednost
momenta je znatno manja od momenta koji se javlja kod iste brzine sa uključenim
zaštitnim otpornikom. Pri korišćenju zaštitnog otpornika napon između krajeva
60
pobudnog namotaja se povećava, to se može dovoditi do proboja izolacije. Ovaj
napon je najveći pri pokretanju motora kao što je prikazano na slici 7.1-16.
ep[V]
2500
1250
-1250
t[s]
-2500
0 0.4 0.8 1.2 1.6 2.0
Sl. 7.1-16 Vrednost indukovanog napona u pobudnom namotaju toku zaleta.
ia[A]
20
15
10
5
0
-5
-10
-15
t[s]
-20
0 0.4 0.8 1.2 1.6 2.0
Sl. 7.1-17 Promene struje jedne faze u toku zaleta.
if[A]
12
-6
-12
t[s]
0 0.4 0.8 1.2 1.6 2.0
Sl. 7.1-18 Promene struje pobudnog namotaja u toku zaleta.
61
Indukovani napon u pobudnom namotaju se može smanjiti smanjivanjem
priključnog napona.
Iz simulacije se vidi da sedlo momenta onemogućuje zalet iznad polovine
sinhrone brzine sa kratkospojenim pobudnim namotajem, dok prevelika otpornost u
kolu rotora (npr. beskonačno – otvoreni krajevi pobudnog namotaja) smanjuje polazni
moment. To znači da treba odrediti optimalnu vrednost zaštitnog otpornika, sa kojim
se krajevi pobudnog namotaja su kratko spajaju.
Kao što mu ime kaže, sinhroni motor u normalnom režimu se obrće sinhronom
brzinom. To znači da rotor se zajedno kreće sa obrtnim magnetnim poljem statora. U
ustaljenom režimu ugao između osa sinhronog koordinatnog sistema (x i y) i
rotorskog koordinatnog sistema (d i q) je konstant. Pri sinhronizaciji se rotor, sa
ugaone brzine ωr< ω1, ubrzava na sinhronu brzinu ω1. Moment koji se pojavljuje u
toku sinhronizacije zove se sinhronizirajući moment.
Sinhronizirajući moment se sastoji iz dva dela, koji su posledica:
- interakcije pobudne struje i magnetnog fluksa,
- asimetrije magnetnog kola - reluktantni moment.
Kod sinhronih motora sa valjkastim rotorom sa uključenjem pobudne struje
može se ostvariti sinhronizacija, dok kod motora sa izraženim polovima često se
odigrava sinhronizacija bez uključivanja pobudne struje. U ovom slučaju reluktantni
moment savlada moment opterećenja. Sinhroni motori u toku zaleta redovno nisu
opterećeni, to znači da se samo moment trenja i ventilacije pojavljuju na vratilu
motora.
62
pobude, i struja koju ostvaruje napajanje pobude), to znači da smer indukovanog
napona u pobudnom namotaju se poklapa sa smerom priključnog napona.
isd[A] isq[A]
20 10
5
0
0
-20
-5
t[s] t[s]
-40 -10
1.5 1.8 2.1 2.4 2.7 3.0 1.5 1.8 2.1 2.4 2.7 3.0
a.) b.)
Sl. 7.2-1 Promene komponenata d i q statorske struje u toku sinhronizacije
ω[s-1] m[Nm]
350 100
80
330
60
310 40
290 20
0
270
t[s] -20 ω[s-1]
250 -40
1.5 1.8 2.1 2.4 2.7 3.0 150 200 250 300 350
a.) b.)
Sl. 7.2-2 Promene ugaone brzine (a.) u toku zaleta i momenta u fukciji ugaone
brzine (b.)
if[A]
40
30
20
10
0
-10
t[s]
-20
1.5 1.8 2.1 2.4 2.7 3.0
Sl. 7.2-3 Promene struje pobudnog namotaja u toku sinhronizacije
63
ia[A]
40
32
24
16
8
0
-8
-16
-24
-32
t[s]
-40
1.5 1.75 2.0 2.25 2.5 2.75 3.0
Sl. 7.2-4 Promene struje prve faze u toku sinhronizacije
ep[V] δ[0]
500 360
400
300
270
200
100
0 180
-100
-200
90
-300
-400 t[s] t[s]
-500 0
1.5 1.8 2.1 2.4 2.7 3.0 1.5 1.8 2.1 2.4 2.7 3.0
a.) b.)
Sl. 7.2-5 Promene indukovanog napona u pobudnom namotaju a.) i promene ugla
između realne ose sinhronog i rotorskog koordinatnog sistema b.) u toku
sinhronizacije
64
isd[A] isq[A]
40 10
5
20
0
0
-5
t[s] t[s]
-20 -10
1.5 1.8 2.1 2.4 2.7 3.0 1.5 1.8 2.1 2.4 2.7 3.0
a.) b.)
Sl. 7.2-6 Promene komponenata d i q statorske struje u toku sinhronizacije
ω[s-1] m[Nm]
350 100
80
330
60
310
40
290 20
0
270
-20
t[s] ω[s-1]
250 -40
1.5 1.8 2.1 2.4 2.7 3.0 150 200 250 300 350
a.) b.)
Sl. 7.2-7 Promene ugaone brzine (a.) u toku zaleta i moment u fukciji ugaone
brzine (b.)
if[A]
20
10
0
-10
-20
-30
t[s]
-40
1.5 1.8 2.1 2.4 2.7 3.0
Sl. 7.2-8 Promene struje pobudnog namotaja u toku sinhronizacije
65
i [A]
40 a
32
24
16
8
0
-8
-16
-24
-32
t[s]
-40
1.5 1.75 2.0 2.25 2.5 2.75 3.0
Sl. 7.2-9 Promene struje prve faze u toku sinhronizacije
ep[V] δ[0]
500 180
400
300
90
200
100
0 0
-100
-200
-90
-300
-400 t[s] t[s]
-500 -180
1.5 1.8 2.1 2.4 2.7 3.0 1.5 1.8 2.1 2.4 2.7 3.0
a.) b.)
Sl. 7.2-10 Promene indukovanog napona u pobudnom namotaju a.) i promene ugla
između realne ose sinhronog i rotorskog koordinatnog sistema b.) u toku
sinhronizacije
Kao što se vidi na slici 7.2-7 a.) prvom povećava se brzina obrtaja, posle rotor
se okreće sa uglom π/2 u sinhronom koordinatnom sistemu kao što je prikazano na
slici 7.2-10 b.).
66
isd[A] isq[A]
20 10
5
0
0
-20
-5
t[s] t[s]
-40 -10
1.5 1.8 2.1 2.4 2.7 3.0 1.5 1.8 2.1 2.4 2.7 3.0
a.) b.)
Sl. 7.2-11 Promene komponenata d i q statorske struje u toku sinhronizacije
ω[s-1] m[Nm]
350 100
80
330
60
310 40
290 20
0
270
t[s] -20
ω[s-1]
250 -40
1.5 1.8 2.1 2.4 2.7 3.0 150 200 250 300 350
a.) b.)
Sl. 7.2-12 Promene ugaone brzine (a.) u toku zaleta i moment u fukciji ugaone
brzine (b.)
if[A]
40
30
20
10
0
-10
-20 t[s]
1.5 1.8 2.1 2.4 2.7 3.0
Sl. 7.2-13 Promene struje pobudnog namotaja u toku sinhronizacije
67
ia[A]
40
32
24
16
8
0
-8
-16
-24
-32
t[s]
-40
1.5 1.75 2.0 2.25 2.5 2.75 3.0
Sl. 7.2-14 Promene struje prve faze u toku sinhronizacije
ep[V] δ[0]
500 360
400
300
200 270
100
0 180
-100
-200
-300 90
-400 t[s] t[s]
-500 0
1.5 1.8 2.1 2.4 2.7 3.0 1.5 1.8 2.1 2.4 2.7 3.0
a.) b.)
Sl. 7.2-15 Promene indukovanog napona a.) i promene ugla između realne ose
sinhronog i rotorskog koordinatnog sistema b.) u toku sinhronizacije
68
isd[A] isq[A]
40 10
5
20
0
0
-5
t[s] t[s]
-20 -10
1.5 1.8 2.1 2.4 2.7 3.0 1.51.8 2.1 2.4 2.7 3.0
a.) b.)
Sl. 7.2-16 Promene komponenata d i q statorske struje u toku sinhronizacije
ω[s-1] m[Nm]
350 100
80
330
60
310 40
290 20
0
270
-20
t[s] ω[s-1]
250 -40
1.5 1.8 2.1 2.4 2.7 3.0 150 200 250 300 350
a.) b.)
Sl. 7.2-17 Promene ugaone brzine (a.) u toku zaleta i momenta u fukciji ugaone
brzine (b.)
if[A]
20
10
0
-10
-20
-30
t[s]
-40
1.5 1.8 2.1 2.4 2.7 3.0
Sl. 7.2-18 Promene struje pobudnog namotaja u toku sinhronizacije
69
ia[A]
40
32
24
16
8
0
-8
-16
-24
-32
t[s]
-40
1.5 1.75 2.0 2.25 2.5 2.75 3.0
Sl. 7.2-19 Promene struje prve faze u toku sinhronizacije
ep[V] δ[0]
500 180
400
300
200 90
100
0 0
-100
-200
-300 -90
-400
-500 t[s] t[s]
-180
1.5 1.8 2.1 2.4 2.7 3.0 1.5 1.8 2.1 2.4 2.7 3.0
a.) b.)
Sl. 7.2-20 Promene indukovanog napona a.) i promene ugla između realne ose
sinhronog i rotorskog koordinatnog sistema b.) u toku sinhronizacije
70
7.2.6 Uključivanje napajanja pobudnog namotaja sa nepravilnim
pobudom
Pri uključivanja pobuda sa nepravilnim polaritetom, rotor u sinhronom
koordinatnom sistemu okreće se za -1800 stepenom. Na slikama 7.2-21 – 7.2-26 su
prikazane promene karakterističnih veličina.
isd[A] isq[A]
10 10
5 5
0 0
-5 -5
t[s] t[s]
-10 -10
2 3 4
5 6 7 8 9 2
3 4 5 6 7 8 9
a.) b.)
Sl. 7.2-21 Promene komponenata d i q statorske struje u toku uključivanja napajanja
pobudnog namotaja sa nepravilnim polaritetom
ω[s-1]
324 5 m[Nm]
320
2.5
316
0
312
-2.5
308
t[s] t[s]
304 -5
2 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9
a.) b.)
Sl. 7.2-22 Promene ugaone brzine i momenta u toku uključivanja napajanja
pobudnog namotaja sa nepravilnim polaritetom
if[A]
15
10
5
0
-5
-10
t[s]
-15
0 1 2 3 4 5 6 7 8 9
Sl. 7.2-23 Promene struje pobudnog namotaja pre i posle sinhronizacije i toku
uključivanja napajanja pobudnog namotaja sa neispravnom polaritetom
71
ia[A]
-4
-8
t[s]
2 3 4 5 6 7 8 9
Sl. 7.2-24 Promene struje jedne faze statora u toku uključivanja napajanja pobudnog
namotaja sa nepravilnim polaritetom.
δ[0]
180
90
-90
t[s]
-180
2 3 4 5 6 7 8 9
Sl.7.2-25 Promene ugla između realne ose sinhronog i rotorskog koordinatnog
sistema u toku uključivanja napajanja pobudnog namotaja sa nepravilnim polaritetom.
ep[V]
20
10
0
-10
-20
t[s]
-30
2 3 4 5 6 7 8 9
Sl. 7.2-26 Indukovani napon u pobudnom namotaju u toku uključivanja napajanja
pobude sa nepravilnim polaritetom.
72
7.2.7 Uključivanja napajanja pobudnog namotaja sa pravilnom pobudom
Pri uključivanju pobude sa pravilnim polaritetom, rotor se ne okreće u
sinhronom koordinatnom sistemu. Na slikama 7.2-27 – 7.2-32 su prikazane promene
karakteristične veličina za ovaj slučaj:
isd[A] isq[A]
10 10
5 5
0 0
-5 -5
t[s] t[s]
-10 -10
2 3 5 64 7 8 9 2 3 4 5 6 7 8 9
a.) b.)
Sl. 7.2-27 Promene komponenata d i q statorske struje u toku uključivanja napajanja
pobudnog namotaja sa pravilnim polaritetom
ω[s-1] m[Nm]
324 5
320
2.5
316
0
312
-2.5
308
t[s] t[s]
304 -5
2 35 6 4 7 8 9 2 3 4 5 6 7 8 9
a.) b.)
Sl.7.2-28 Promene ugaone brzine i momenta u toku uključivanja napajanja pobudnog
namotaja sa pravilnim polaritetom
if[A]
15
10
5
0
-5
-10
t[s]
-15
0 1 2 3 4 5 6 7 8 9
Sl. 7.2-29 Promene struje pobudnog namotaja pre i posle sinhronizacije i toku
uključivanja napajanja pobudnog namotaja sa pravilnim polaritetom
73
ia[A]
-4
-8
t[s]
2 3 4 5 6 7 8 9
Sl. 7.2-30 Promene struje jedne faze statora u toku uključivanja napajanja pobudnog
namotaja sa pravilnim polaritetom.
δ[0]
270
180
90
t[s]
-90
2 3 4 5 6 7 8 9
Sl. 7.2-31 Promene ugla između realne ose sinhronog i rotorskog koordinatnog
sistema u toku uključivanja napajanja pobudnog namotaja sa pravilnim polaritetom.
ep[V]
20
10
0
-10
-20
t[s]
-30
2 3 4 5 6 7 8 9
Sl. 7.2-32 Indukovani napon u pobudnom namotaju u toku uključivanja napajanja
pobude sa pravilnom polaritetom.
74
mehanički vremenski konstant se može zanemariti. Na slikama 7.2-27 a.) i 7.2-29 se
vidi da se sa povećavanjem struje pobude smanjuje d-komponenta struje statora.
U prethodnim simulacijama se vidi da pravilan polaritet pobude zavisi od
zadnjeg predznaka struje pobudnog namotaja. Polaritet struje pobudnog namotaja pre
ulaska u sinhronizam i ispravan polaritet napajanja pobude se razlikuju.
isd[A] isq[A]
0 10
-2.5 7.5
-5 5
-7.5 2.5
t[s] t[s]
-10 0
6.5 77.5 8 8.5 9 6.5
7 7.5 8 8.5 9
a.) b.)
Sl.7.3-1 Promene komponenata d i q statorske struje pri povećanju opterećenja
ω[s-1] m[Nm]
325 30
320 25
20
315
15
310
10
305 t[s] 5 t[s]
300 0
6.5 7 7.5 8 6.57 7.5 8 8.5 9
a.) b.)
Sl. 7.3-2 Promene ugaone brzine i momenta pri povećanju opterećenja
75
if[A]
15
12
3
t[s]
0
6.5 7 7.5 8 8.5 9
Sl. 7.3-3 Promene struje pobudnog namotaja pri povećanju opterećenja
ia[A]
10
-5
t[s]
-10
6.5 7 7.5 8 8.5 9
Sl. 7.3-4 Promene struje jedne faze statora pri povećanju opterećenja.
δ[0]
180
165
150
135
120
105
t[s]
90
6.5 7 7.5 8 8.5 9
Sl. 7.3-5 Promene ugla između realne ose sinhronog i rotorskog koordinatnog sistema
pri povećavanju momenta opterećenje
76
Na slikama 7.3-6 – 7.3-10 su prikazane promene struja i mehaničkih veličina pri
naglom smanjenju opterećenje.
isd[A] isq[A]
5 10
2.5 7.5
0 5
-2.5 2.5
t[s] t[s]
-5 0
6.5 77.5 8 8.5 9 7 6.5
7.5 8 8.5 9
a.) b.)
Sl.7.3-6 Promene komponenata d i q statorske struje pri smanjenju opterećenja.
ω[s-1] m[Nm]
325 20
322
15
319
10
316
t[s] t[s]
5
313
310 0
6.5 7 7.5 8 8.5 9 7 6.5
7.5 8 8.5 9
a.) b.)
Sl. 7.3-7 Promene ugaone brzine i momenta pri smanjenju opterećenja.
if[A]
9
t[s]
-3
6.5 7 7.5 8 8.5 9
Sl. 7.3-8 Promene struje pobudnog namotaja pri smanjenju opterećenja.
77
ia[A]
10
-5
t[s]
-10
6.5 7 7.5 8 8.5 9
Sl. 7.3-9 Promene struje jedne faze statora pri smanjenju opterećenja.
δ[0]
180
165
150
135
120
105
t[s]
90
6.5 7 7.5 8 8.5 9
Sl. 7.3-10 Promene ugla između realne ose sinhronog i rotorskog koordinatnog
sistema pri smanjenju opterećenja.
78
isd[A] isq[A]
7.5 7.5
5 5
2.5 2.5
0 0
-2.5 -2.5
-5 -5
t[s] t[s]
-7.5 -7.5
6.5 77.5 8 8.5 9 6.5 7 7.5 8 8.5 9
a.) b.)
Sl. 7.4-1 Promene komponenata d i q statorske struje u slučaju prekida u dovodu
pobudne struje.
ω[s-1] m[Nm]
325 10
310 8
295 6
280 4
265 2
t[s] t[s]
250 0
6.5 7
7.5 8 8.5 9 6.5 7 7.5 8 8.5 9
a.) b.)
Sl. 7.4-2 Promene ugaone brzine i momenta u slučaju prekida u dovodu pobudne
struje
m[Nm]
10
2
pωr[s-1]
0
250 260 270 280 290 300 310 320
Sl. 7.4-3 Promene momenta u fukciji ugaone brzine u slučaju prekida u dovodu
pobudne struje
79
ep[V] if[A]
900 7
750 6
t[s] 5
600
4
450
3
300
2
150 1
0 0
-150 -1
-300 -2
-450 -3 t[s]
6.5 7 7.5 8 8.5 9 6.5 7 7.5 8 8.5 9
a.) b.)
Sl. 7.4-4 Promene indukovanog napona i struje pobudnog namotaja u slučaju prekida
u dovodu pobudne struje
ia[A]
7.5
5
2.5
0
-2.5
-5
t[s]
-7.5
6.75 7 7.25 7.5 7.75 8
Sl. 7.4-5 Promene struje jedne faze statora u slučaju prekida u dovodu pobudne struje
80
8. ANALIZA RADA SINHRONIH MOTORA SA
IZRAŽENIM POLOVIMA U USTALJENIM REŽIMIMA
Pri zaletu struja pobudnog namotaja ima nultu vrednost, i zbog velike otpornosti
prigušnog kaveza moment i struja motora imaju male vrednosti. Na slikama 8.1-1 i
8.1-2 su prikazane promene struja i momenta u toku zaleta u funkciji klizanja.
6
M[Nm]
s[]
0
0 0.2 0.4 0.6 0.8 1
Sl. 8.1-1 Promene momenta motora u funkciji klizanja
81
[A] [A]
8 4
Ia
6 Isd 3
IDd
4 Isq 2
2 1
s[] IDq s[]
0 0
0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1
a.) b.)
Sl. 8.1-2 Promene komponenata d i q struje statora, i promene efektivne vrednosti
struje jedne faze (a.), i promene komponenata d i q struje prigušnog kaveza (b.).
M[Nm]
40
20
-20
-40
s[]
-60
0 0.2 0.4 0.6 0.8 1
Sl. 8.1-3 Promene momenta motora u funkciji klizanja
82
[A]
40 [A] 40
Ia
Isd
30 30
20 20
10 10 If
Isq
s[] s[]
0 0
0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1
a.) b.)
Sl. 8.1-4 Promene komponenata d i q struje statora(a.), promene efektivne vrednosti
struje jedne faze i promene struje pobudnog namotaja (b.).
2
[A]
1.5
IDq
1
0.5
IDd s[]
0
0 0.2 0.4 0.6 0.8 1
Sl. 8.1-5 Promene komponenata d i q struje prigušnog kaveza
Upoređenjem momentne karakteristike 8.1-3 i 8.1-1 vidi se da asimetrija
otpornosti u rotorskom kolu u većoj meri utiče na sedlo, koje se javlja u momentnim
karakteristikama.
83
15 M[Nm]
10
5
0
-5
-10
s[]
-15 0 0.2 0.4 0.6 0.8 1
Sl. 8.1-6 Promene momenta motora u funkciji klizanja
16 16
[A] Isd [A] Ia
12 12
8 8
If
4 4
Isq
s[] s[]
0 0
0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1
Sl. 8.1-7 Promene komponenata d i q struje statora(a.), promene efektivne vrednosti
struje jedne faze i promene struje pobudnog namotaja (b.)
1
[A]
0.8
IDq
0.6
0.4
0.2
IDd s[]
00 0.2 0.4 0.6 0.8 1
Sl. 8.1-8 Promene komponenata d i q struje prigušnog kaveza
84
M[Nm]
16
12
0 s[]
0 0.2 0.4 0.6 0.8 1
Sl. 8.1-9 Promene momenta motora u funkciji klizanja
16 [A] 16 [A]
Ia
12 Isd 12
8 8
If
4 4
Isq
0 s[] 0 s[]
0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1
Sl. 8.1-10 Promene komponenata d i q struje statora(a.), promene efektivne
vrednosti struje jedne faze i promene struje pobudnog namotaja (b.)
4
[A]
3
IDd
1
IDq
0 s[]
0 0.2 0.4 0.6 0.8 1
Sl. 8.1-11 Promene komponenata d i q struje prigušnog kaveza
85
8.1.5 Zalet sa zaštitnom otpornikom i predimpedansom
Na sledećim slikama prikazano je u kolikoj meri utiče predimpedansa na
karakteristike momenta i struje.
M[Nm]
12
10
8
6
4
2
s[]
0
0 0.2 0.4 0.6 0.8 1
Sl. 8.1-12 Promene momenta motora u funkciji klizanja
10 10
[A] [A]
8 8
Isd Ia
6 6
4 4
Isq If
2 2
s[] s[]
0 0
0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1
Sl. 8.1-13 Promene komponenata d i q struje statora(a.), promena efektivne vrednosti
struje jedne faze i promena struje pobudnog namotaja (b.)
[A]
16
IDd
12
4
IDq
s[]
0
0 0.2 0.4 0.6 0.8 1
Sl. 8.1-14 Promene komponenata d i q struje prigušnog kaveza
86
9. REZULTATI MERENJA
87
Sl. 9.1-1. Promene struje jedne faze u toku zaleta sa otvorenim pobudnim namotajem
Sl. 9.1-2. Promene struje jedne faze statora sa kratkospojenim pobudnim namotajem
88
Sl. 9.1-3. Promene struje kratkospojenog pobudnog namotaja
89
Sl. 9.1-5. Promene struje pobudnog namotaja sa zaštitnim otpornikom
Sl. 9.2-1 Promene struje jedne faze tokom sinhronizacije sa pravilnim polaritetom
napajanje pobudnog namotaja (sinhronizacija se vrši pomoću pobudne struje)
90
Sl. 9.2-2 Promene struje pobudnog namotaja tokom sinhronizacije sa pravilnim
polaritetom pobudnog napona (sinhronizacija se vrši pomoću pobudne struje)
Sl. 9.2-3 Promene struje jedne faze tokom sinhronizacije sa nepravilnim polaritetom
pobudnog namotaja (sinhronizacija se vrši pomoću pobudne struje)
91
Sl. 9.2-4 Promene struje pobudnog namotaja tokom sinhronizacije sa nepravilnim
polaritetom pobudnog napona (sinhronizacija se vrši pomoću pobudne struje)
Pri naglom porastu opterećenja motora povećava se struja statora, što indukuje
napon u pobudnom namotaju. U toku merenja bile su merene naizmenične
komponente, jer struja statora i pobudnog namotaja je merena preko strujnog
transformatora. Sa naglim povećajem amplitude struje faznog namotaja povećava se i
struja pobudnog namotaja. Zbog konstantog napona napajanja smanjuje se struja
pobudnog namotaja, i preko ovih tranzijenata izobličava se nova struja statora. Na
slikama 9.3-1 i 9.3-2 su prikazane promene struje jedne faze statora i pobudnog
namotaja za slučaj naglog povećavanja opterećenja.
Sl. 9.3-1 Promene struje jedne faze pri naglom uključivanju opterećenja
92
Sl. 9.3-2 Promene struje pobudnog namotaja pri naglom uključivanju opterećenja
Sl. 9.3-3 Promene struje jedne faze pri naglom isključenju opterećenja
93
Sl. 9.3-4 Promene struje pobudnog namotaja pri naglom isključenju opterećenja
Pri prekidu struje napajanja pobudnog namotaja, strujno kolo se zatvara preko
zaštitnog otpornika. Struja zaštitnog otpornika pulsira frekvencijom sf1. Dužine
perioda struje pobudnog namotaja i tranzijenta struja faznih namotaja su jednaki, kao
što je prikazano na slikama 7.4-4 b.) i 7.4-5. Razlike između slika 7.4-5 i 9.4-2 su
posledice različitih opterećenja modela i realnog motora. Na slici 9.4-1 su prikazane
promene struje pobudnog namotaja, koja sadržava visoke harmonike koji su posledica
ožlebljenja statora (žlebni harmonici).
9.4-1 Promene struje pobudnog namotaja pri naglom prekidu pobudne struje
94
9.4-2 Promena struje jedne faze pri naglom prekidu pobudne struje
95
10. ZAKLJUČAK
96
Razlike između dužine tranzijenata simulacije i merenja su posledice razlike
inercije realnog motora i modela.
Rezultati simulacije i merenja su pokazili način određivanja pravilnog polariteta
napajanja popbudnog namotaja, i uticaja zaštitnog otpornika na promenu momenta u
toku zaleta.
U modelima sinhronog motora sa izraženim polovima nisu uzeti u obzir
zasićenje magnetnog kola i potiskivanje struje u prigušnom kavezu, čime u daljnjim
simulacijama treba dopuniti model.
Pored proširenja modela, drugi smer daljnjih istraživanja je određivanje
kompleksne jednačine u drugim asimetričnim slučajevima, koji su do sada bili
diskutovani pomoću direktnih i indirektnih komponenata za ustaljeni režim.
97
11. LITERATURA
98
УНИВЕРЗИТЕТ У НОВОМ САДУ ОБРАЗАЦ - 7
НАЗИВ ФАКУЛТЕТА
I ПОДАЦИ О КОМИСИЈИ
2. Састав комисије са назнаком имена и презимена сваког члана, звања, назива уже научне области за
коју је изабран у звање, датума избора у звање и назив факултета, установе у којој је члан комисије
запослен:
1. др Борислав Јефтенић (председник), ванредни професор, у.н.о. електромоторни погони и регулација,
09. 03. 2006., Електротехнички факултет, Београд
2. др Владимир Катић редовни професор, у.н.о. енергетска електроника, машине и погони, 30.10.2002.,
Факултет техничких наука, Нови Сад.
3. др. Дарко Марчетић, доцент, у.н.о. енергетска електроника, машине и погони, 01.04.2007., Факултет
техничких наука, Нови Сад
4. др Филип Кулић, доцент, уно Аутоматика и управљање системима, 20.11.2003, Факултет техничких наука,
Нови Сад
5. др Веран Васић (ментор), ванредни професор, у.н.о. енергетска електроника, машине и погони,
17.05.2006., Факултет техничких наука, Нови Сад
II ПОДАЦИ О КАНДИДАТУ
Магистарски рад кандидата Иштвана Кираља, дипл. инж., садржи 97 нумерисаних страница текста А4
формата подељеног у једанаест поглавља. Текст садржи 110 слика. Поред текста рад садржи и
библиографију са 13 цитирана извора. Рад садржи следећа поглавља:
1. Увод
2. Синхрони мотори
3. Просторни вектори у природним координатним системима
4. Просторни вектори и једначине у заједничком општем координатном систему
5. Начин симулације утицаја губитака снаге у гвожђу статора
6. Устаљени режим синхроног мотора
7. Симулације синхроних мотора са израженим половима у прелазним режимима
8. Анализа рада синхроних мотора са израженим половима у устаљеним режимима
2
9. Резултати мерења
10. Закључак
11. Литература.
Прво поглавље је уводно и даје преглед о данашњим електромоторним погонима. Поглавље садржи
преглед примена синхроних мотора код погона велике снаге. Затим је дат увод у проблематику симулације
асиметрије електричних машина, и дат је кратак опис рада.
У циљу бољег разумевања рада синхроног мотора, у другом поглављу је приказан принцип рада, и
изведбе ротора различитих врста мотора. Дат је детаљан опис шеме погона асинхроног покретање
синхроног мотора. Поред шеме кратко су дефинисани асинхрони режими, и описани су специфичности
синхроног мотора са израженим половима.
jθ − jθ
У циљу елиминисања ротатора e , e из израза флуксних обухвата и напонских диференцијалних
једначина, у четвртом поглављу уведен је заједнички општи координатни систем. После дефиниције општег
координатног система, приказане су трансформације просторних вектора статора и ротора у наведеним
координатним системима. Са добијеним просторним векторима написани су изрази флуксних обухвата и
напонских једначина. Након тога су приказана распрезања просторних вектора у скаларне компоненте и у
тренутне вредности по фазама. У оквиру овог поглавља приказан је и начин за одређивања нултих
компонената струја и напона статора и ротора.
У петом поглављу извршено је проширење напонских једначина успостављених у четвртом поглављу.
Допуна се односи на уважавање губитака у гвожђу статора. На основу напонских диференцијалних
једначина дати су изрази тренутних снага, тренутних губитака снага и тренутни изрази момента. Добијени
систем напонских једначина, чији координатни систем тако одабран да се поклапа са природним
координатним системом ротора, допуњен је са скаларном диференцијалном једначином побудног намотаја.
На крају поглавља дат је израз за моменат синхроног мотора са израженим половима и Њутнова једначина
обртног кретања.
У трећем и четвртом поглављу детаљно су приказани математички модели електричних машина, као што је
веза између природних координатних система и општег координатног система. Детаљно су приказане везе
између комплексних просторних вектора и фазних величина, као и распрезања тих вектора на скаларне
компоненте и на трофазне компоненте.
Математички модел синхроног мотора који је развијен из претходних диференцијалних једначина, је дат у
петом поглављу. Овај модел уважава губитке у гвожђу статора, скаларну диференцијалну једначину
побудног намотаја, и омогућава детаљно проучавање понашање синхроног мотора са израженим половима у
разним асинхроним режимима, ка што су:
• Асинхрони залети;
• синхронизација;
• нагла промена оптерећења.
У развијеном математичком моделу узети су у обзир губици у гвожђу статора, чији се утицај не сме
занемарити код великих мотора. Ово доводи до прецизнијег прорачуна код погона које садрже синхроне
моторе. У овом делу комплетно и јасно су изложени принципи на којима се нови модел темељи.
У шестом поглављу приказан је начин за одређивање комплексних једначина мотора на основу система
диференцијалних једначина. Ове комплексне једначине омогућавају прецизније прорачуне од метода
инверзних и директних компонената за устаљене режиме. Додатна вредност поглавља је јасно изложена
упутства за одређивање нове једначине.
У седмом поглављу је приказана детаљна анализа различитих асинхроних режима синхроног мотора.
Приликом моделовања асинхроног залета представљена су три различита случаја, из којих се види утицај
предимпеданси и заштитног отпорника. На основу резултата се може дефинисати да одговарајући заштитни
отпорник у великој мери утиче на струју и момента мотора. Поред значаја заштитног отпорника на залет,
приказани су утицаји исправне и неисправне синхронизације помоћу побудне струје, утицај исправног и
неисправног поларитета струје побудног намотаја у случају синхронизација са релуктантним моментом. На
основу ових резултата дат је предлог како да се одабере исправан поларитет побудне струје за оба случаја.
Остали резултати симулације показују промене струја, момента и електричне угаоне брзине у току
асинхроних режима.
У осмом поглављу су приказане промене ефективне вредности струје и момента мотора током спорог
залета. Корисност ових прорачуна је у томе, да су добијени резултати ефективне вредности струја, који су
потребни за подешавање заштите мотора. Поред одређивања заштите, моментне карактеристике помажу
одређивању оптеретљивости синхроног мотора током залета.
Као научна верификација рада на тези служе и радови које је кандидат током израде магистарске тезе
публикова као аутор на домаћим и међународним научним конференцијама. Објављени радови су:
1. Jožef Varga, Ištvan Kiralj: “Ponašanja sinhronih motora u nenormalnim asinhronim režimima rada “, 14. Int.
Symposium on Power Electronics'- Ee2007, Novi Sad (Serbia), Nov.7-9, 2007, ISBN 86-7892-065-3, Paper
No. T2-2.3, Proceedings on CD ROM.
Поред ових радова који се непосредно односе на садржај магистарске тезе, кандидат је током
постдипломских студија, на стручним конференцијама објавио и следеће радове као први аутор или коаутор,
који додатно потврђују његову склоност према научноистраживачком раду.
1. Jožef Varga, Ištvan Kiralj: “Statičko i dinamičko ponašanje trofaznih asinhronih motora sa kaveznim
rotorom u slučajevima iznenadnog prekida dovoda jedne faze“, 12. Int. Symposium on Power Electronics'-
Ee2003, Novi Sad (Serbia and Montenegro), Nov.5-7, 2003, ISBN 868024974-2, Paper No. T3-2.2,
Proceedings on CD ROM.
2. Jožef Varga, Ištvan Kiralj: “Analiza rada jednofaznih asinhronih motora sa zasenčenim polovima metodom
dvofaznih ortogonalno pulsirajućih harmonijskih polja”, 12. Int. Symposium on Power Electronics'-Ee2003,
Novi Sad (Serbia and Montenegro), Nov.5-7, 2003, ISBN 868024974-2, Paper No. T3-2.5, Proceedings on
CD ROM.
4
3. Ištvan Kiralj: “Analiza strujnog i naponskog spektra kod asinhronog motora napajanog preko naponskog
invertora“, 13. Int. Symposium on Power Electronics – Ee2005, Novi Sad (Serbia and Montenegro), Nov.2-4,
2005, ISBN 86-85211-44-1, Paper No. T3-4.3, Proceedings on CD ROM.
4. Jožef Varga, Ištvan Kiralj: “Simulacija ponašanje kliznokolutnih asinhronih motora u slučajevima
iznenadnog prekida jedne faze kod rotorskog namotaja “, 13. Int. Symposium on Power Electronics – Ee2005,
Novi Sad (Serbia and Montenegro), Nov.2-4, 2005, ISBN 86-85211-44-1, Paper No. T3-4.1, Proceedings on
CD ROM.
5
VI ЗАКЉУЧЦИ ОДНОСНО РЕЗУЛТАТИ ИСТРАЖИВАЊА
Предмет научне анализе у овом раду везан је за проучавање асинхроних режима синхроног мотора са
израженим половима.
У данашњим погонима често су коришћени синхрони мотори са израженим половима. Код ових погона
поред предвиђеног рада појављују се различити асинхрони режими, који се морају добро познавати и
изучити у циљу пројектовање ефикасне заштите. Ови асинхрони режими су:
• асинхрони залет;
• синхронизације (укључивањем побудне струје, релуктантним моментом);
• нагла промена оптерећење;
• прекид у доводу напајање побуде.
Теза садржи све потребне елементе научноистраживачког рада. Полази се од теоретског разматрања
проблематике истраживања и дефинисања циљева које се желе постићи. Формиран је математички модел
комплетног електромотора.
Следећи корак у раду представља рачунарска симулација модела у циљу верификације теоретских анализа.
За симулацију је кориштен један од најпознатијих и најпоузданијих програма, MathCAD 2001 Profesional.
Сваки параметар од интереса је приказан и лако се може пратити исправност диференцијалних једначина и
формуле за одређивања снаге.
Да би се резултати потврдили и експериментално, моделиран и испитиван је један конкретни мотор.
Симулациони и експериментални резултати су потврдили теоретске претпоставке и валидност описаног
модела синхроног мотора са израженим половима.
Дијаграми мерења су приказани, и упоређени са резултатима симулације. Читав рад је илустрован знатним
бројем слика, шема и дијаграма. Додатна потврда оригиналности истраживања је публиковање резултата
истраживања на домаћим и међународним конференцијама.
Кандидат је изложио резултате истраживања у веома јасној и разумљивој форми. Текст магистарске тезе је
испуњен коментарима аутора и сликама које појашњавају на задовољавајући начин све уведене појмове.
Теза представља један комплетан научно-истраживачки рад. Предмет истраживања је једна актуелна тема:
асинхрони режими синхроних мотора са израженим половима. Оригиналност тезе огледа се у предложеном
новом моделу за уважавање губитака у гвожђу статора. Уведена је нова техника за одређивање комплексне
једначине асинхроних устаљених режима синхроних мотора са израженим половима. Резултати добијених
путем мерења у потпуности се слажу са резултатима симулације, чиме су потврђене полазне теоретске
претпоставке. Одређивање комплексних једначина је решило недостатак ранијих решења са методом
инверзних и директних компонената.
IX ПРЕДЛОГ:
На основу укупне оцене тезе, комисија предлаже:
- да се магистарска теза прихвати а кандидату одобри одбрана
- да се магистарска теза враћа кандидату на дораду (да се допуни односно измени) или
- да се магистарска теза одбија
______________________________________________
др Борислав Јефтенић, ванр. проф., ЕТF, Београд
_____________________________________________
др Владимир Катић, ред. проф., FТН, Нови Сад
__________________________________________
др Дарко Марчетић, доцент, FТН, Нови Сад
___________________________________________________
др Филип Кулић, ванр. проф., FТН, Нови Сад
___________________________________________________
др Веран Васић, ванр. проф., FТН, Нови Сад
НАПОМЕНА: Члан комисије који не жели да потпише извештај јер се не слаже са мишљењем већине
чланова комисије, дужан је да унесе у извештај образложење односно разлоге због којих не жели да
потпише извештај.