S3-35 - Tower 1 Shear Wall Section
S3-35 - Tower 1 Shear Wall Section
OWNER
Ortigas&Company
Limited Partnership
9/F ORTIGAS BUILDING,ORTIGAS AVENUE, PASIG CITY
TELEPHONE: (632)631-1231 TO 38 FAX:(632)631-6517
T1-1
CROSSTIES & HOOPS CROSSTIES & HOOPS CROSSTIES & HOOPS CROSSTIES & HOOPS THOMAS F. MIRASOL
AT 200mm VERT SPCG AT 200mm VERT SPCG AT 200mm VERT SPCG AT 200mm VERT SPCG CHIEF OPERATING OFFICER, SENIOR VICE
PRESIDENT & GENERAL MANAGER
REAL ESTATE DIVISION
ARCHITECT OF RECORD
GF & Partners
A r c h i t e c t s
ANNETTE F. GADDI-LIGANOR
A R C H I T E C T
PRC REG. NO. : 6813 DATE: 11-12-1982 TIN : 108-782-800
PTR NO. : 4754954 DATE: 01-12-2015 PLACE : MAKATI CITY
TEODORO H. NARCISO TEOFILO A. SANTIAGO JR.
ANNETTE F. GADDI-LIGANOR ARNULFO M. VILLANUEVA
XAVIER ANTONIO J. GARCIA
11TH FLOOR, BDO PLAZA, 8737 PASEO DE ROXAS, MAKATI CITY, PHILIPPINES
CROSSTIES & HOOPS CROSSTIES & HOOPS CROSSTIES & HOOPS CROSSTIES & HOOPS TELEPHONE (632) 553-7232 FAX (632) 553-7230 E-MAIL: postmaster@gfparchitects.com
incorporated
ASSOCIATES JOSE A. SY
STRUCTURAL ENGINEER
Unit 504 Pryce Center, 1179 Chino Roces Avenue
cor. Bagtican St., Makati City REG. NO. 22404 TIN 123-489-697
Telephone No. 896-97-04 to 05
Fax No. 896-97-60 to 61 PTR NO. 5330036 DATE 01-07-16
e-mail address: info@sysquared.com PLACE MAKATI CITY
TYP CORNER
email : ebc@philonline.com.ph
1350
E F R E N B. C R U Z
PROFESSIONAL ELECTRICAL ENGINEER
T1-2
450
450
MECHANICAL
1350
ISSUED AT
SANITARY ENGINEER
FIRE PROTECTION
DCCD ENGINEERING CORPORATION
SOL BUILDING 112 AMORSOLO ST., MAKATI M.M.
TEL. NOS. 892-45-86 TO 89
T1-3
FIRE PROTECTION ENGINEER
CONSTRUCTION MANAGER
T1-4
TYP END
1200
QUANTITY SURVEYOR
CROSSTIES & HOOPS CROSSTIES & HOOPS CROSSTIES & HOOPS CROSSTIES & HOOPS
AT 200mm VERT SPCG AT 200mm VERT SPCG AT 200mm VERT SPCG AT 200mm VERT SPCG
Arcadis Philippines, Inc.
4th Floor King's Court 1, 2129 Pasong Tamo Makati City
Tel: +632 8112971 Fax: +632 8112071
E-mail: info-ph@arcadis.com www.arcadis.com
REVISIONS
NO. DATE DESCRIPTION
NOTES:
CROSSTIES & HOOPS CROSSTIES & HOOPS CROSSTIES & HOOPS CROSSTIES & HOOPS
SHOULD THERE BE DISCREPANCIES, CONFLICTS
AT 200mm VERT SPCG AT 200mm VERT SPCG AT 200mm VERT SPCG AT 200mm VERT SPCG AND/OR AMBIGUITIES ON THE CONSTRUCTION
DOCUMENTS (ie. ARCH'L., ENGINEERING DRAWINGS,
TECH'L. SPECS ETC.), THE CONTRACTOR SHOULD
FIRST CALL THE ATTENTION OF THE DESIGNERS FOR
CLARIFICATION BEFORE PROCEEDING WITH THE WORK
ON THE AREA CONCERNED.
1. ALL CROSSTIES AND HOOPS TO BE T16 @ 150mm VERTICAL SPACING WITH Fy = 60 KSI TYPICAL, UNLESS NOTED OTHERWISE. SHEET CONTENTS
16 1 : 50