Professional Documents
Culture Documents
Emission Control System - Corsa 1.4 97-00
Emission Control System - Corsa 1.4 97-00
Telephone:
Fax:
VAT Registration No.:
Emission control system
Oxygen sensor (O2S) - Corsa-B/Tigra (X14XE/X16XE) 09/95-00
Checking supply voltage - Fig. 20
Technical Data
Terminals Voltage
O2S & earth 350-550 mV
Checking signal - Fig. 20
Technical Data
Terminals Condition Voltage
O2S & earth 1300 rpm 50-950 mV (fluctuating)
Heated oxygen sensor (HO2S) - except Corsa-B/Tigra (X14XE/X16XE) 09/95-00
Checking supply voltage - Fig. 21
Technical Data
Engine Terminals Voltage
C16XE C & earth 430-470 mV
X14XE/X16XE/X16XEL C & earth 350-550 mV
Checking signal - Fig. 21
Technical Data
Terminals Condition Voltage
C & earth 1300 rpm 50-950 mV (fluctuating)
Oxygen sensor heater
Checking supply voltage - Fig. 21
Technical Data
Terminals Condition Voltage
A&B Ignition ON Battery voltage
Secondary air injection (AIR) solenoid
Checking supply voltage - Fig. 3 & Fig. 22
Technical Data
Terminals Condition Voltage
1 & earth Ignition ON Battery voltage
Secondary air injection (AIR) pump
Checking operation - Fig. 3
Exhaust gas recirculation (EGR) solenoid
Checking resistance - Fig. 23
Technical Data
Terminals Resistance
A&E 7-10 W
B&D 3000-7000 W
Technical Data
Terminals Condition Voltage
D & earth Ignition ON 4,9-5,1 V
E & earth Ignition ON Battery voltage
Evaporative emission (EVAP) canister purge valve
Checking resistance - Fig. 24
Technical Data
Terminals Condition Resistance
A&B Ignition OFF 30-40 W
Checking supply voltage - Fig. 3 & Fig. 24
Technical Data
Terminals Condition Voltage
B & earth Ignition ON Battery voltage
20
3 22
23 24