You are on page 1of 28

ELECTROCOATS DOC. NO.

: SST/01

REV. NO. : 02
Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA)
SALT SPRAY TEST REPORT DATE : 20 - 04REV.
- 2022
DATE : 02/12/2021
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 602 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4103 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 4/11/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 4/20/2022 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 196 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 4/12/2022 03 : 10 PM NO WHITE RUST OBSERVED OK

48 Hours 4/13/2022 03 : 10 PM NO WHITE RUST OBSERVED OK

72 Hours 4/14/2022 03 : 10 PM NO WHITE RUST OBSERVED OK

96 Hours 4/15/2022 03 : 10 PM NO WHITE RUST OBSERVED OK

OBSERVATION 120 Hours 4/16/2022 03 : 10 PM NO WHITE RUST OBSERVED OK

144 Hours 4/17/2022 03 : 10 PM MINOR WHITE RUST OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


168 Hours 4/18/2022 03 : 10 PM OBSERVED OK

192 Hours 4/19/2022 03 : 10 PM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 4/20/2022 03 : 10 PM OBSERVED OK

REMARKS : Minor White Rust observed Up to 144 Hours But No Red Rust Observed Up To 196 Hours .Test Discontinue after 198 Hours (End)
NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .
PREPARED & TESTED BY : APPROVED BY :
MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01

REV. NO. : 02
Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA)
SALT SPRAY TEST REPORT DATE : 23 - 05REV.
- 2022
DATE : 02/12/2021
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 8601 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4137 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 5/10/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 5/23/2022 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 5/11/2022 01 : 40 PM NO WHITE RUST OBSERVED OK

48 Hours 5/12/2022 01 : 40 PM NO WHITE RUST OBSERVED OK

72 Hours 5/13/2022 01 : 40 PM NO WHITE RUST OBSERVED OK

96 Hours 5/14/2022 01 : 40 PM NO WHITE RUST OBSERVED OK

120 Hours 5/15/2022 01 : 40 PM NO WHITE RUST OBSERVED OK

144 Hours 5/16/2022 01 : 40 PM NO WHITE RUST OBSERVED OK

MINOR WHITE RUST OBSERVED BUT NO


168 Hours 5/17/2022 01 : 40 PM RED RUST OBSERVED OK
OBSERVATION

192 Hours 5/18/2022 01 : 40 PM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 5/19/2022 01 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 5/20/2022 01 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 5/21/2022 01 : 40 PM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 5/22/2022 01 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 5/23/2022 01 : 40 PM OBSERVED OK

REMARKS : Minor White Rust observed Up to 168 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01

REV. NO. : 02
Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA)
SALT SPRAY TEST REPORT DATE : 17 - 06REV.
- 2022
DATE : 02/12/2021
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 984 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4144 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 6/4/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 6/17/2022 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 6/5/2022 02 : 20 PM NO WHITE RUST OBSERVED OK

48 Hours 6/6/2022 02 : 20 PM NO WHITE RUST OBSERVED OK

72 Hours 6/7/2022 02 : 20 PM NO WHITE RUST OBSERVED OK

96 Hours 6/8/2022 02 : 20 PM NO WHITE RUST OBSERVED OK

120 Hours 6/9/2022 02 : 20 PM NO WHITE RUST OBSERVED OK

144 Hours 6/10/2022 02 : 20 PM NO WHITE RUST OBSERVED OK

MINOR WHITE RUST OBSERVED BUT NO


168 Hours 6/11/2022 02 : 20 PM RED RUST OBSERVED OK
OBSERVATION

192 Hours 6/12/2022 02 : 20 PM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 6/13/2022 02 : 20 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 6/14/2022 02 : 20 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 6/15/2022 02 : 20 PM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 6/16/2022 02 : 20 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 6/17/2022 02 : 20 PM OBSERVED OK

REMARKS : Minor White Rust observed Up to 168 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01

REV. NO. : 02
Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA)
SALT SPRAY TEST REPORT DATE : 16 - 07REV.
- 2022
DATE : 02/12/2021
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 2664 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4161 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 6/3/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 7/16/2022 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 7/4/2022 02 : 50 PM NO WHITE RUST OBSERVED OK

48 Hours 7/5/2022 02 : 50 PM NO WHITE RUST OBSERVED OK

72 Hours 7/6/2022 02 : 50 PM NO WHITE RUST OBSERVED OK

96 Hours 7/7/2022 02 : 50 PM NO WHITE RUST OBSERVED OK

120 Hours 7/8/2022 02 : 50 PM NO WHITE RUST OBSERVED OK

144 Hours 7/9/2022 02 : 50 PM NO WHITE RUST OBSERVED OK

MINOR WHITE RUST OBSERVED BUT NO


168 Hours 7/10/2022 02 : 50 PM RED RUST OBSERVED OK
OBSERVATION

192 Hours 7/11/2022 02 : 50 PM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 7/12/2022 02 : 50 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 7/13/2022 02 : 50 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 7/14/2022 02 : 50 PM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 7/15/2022 02 : 50 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 7/16/2022 02 : 50 PM OBSERVED OK

REMARKS : Minor White Rust observed Up to 168 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01

REV. NO. : 02
Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA)
SALT SPRAY TEST REPORT DATE : 16 - 09REV.
- 2022
DATE : 02/12/2021
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 3508 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4183 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 9/3/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 9/16/2022 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 9/4/2022 09 : 40 AM NO WHITE RUST OBSERVED OK

48 Hours 9/5/2022 09 : 40 AM NO WHITE RUST OBSERVED OK

72 Hours 9/6/2022 09 : 40 AM NO WHITE RUST OBSERVED OK

96 Hours 9/7/2022 09 : 40 AM NO WHITE RUST OBSERVED OK

120 Hours 9/8/2022 09 : 40 AM NO WHITE RUST OBSERVED OK

144 Hours 9/9/2022 09 : 40 AM NO WHITE RUST OBSERVED OK

MINOR WHITE RUST OBSERVED BUT NO


168 Hours 9/10/2022 09 : 40 AM RED RUST OBSERVED OK
OBSERVATION

192 Hours 9/11/2022 09 : 40 AM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 9/12/2022 09 : 40 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 9/13/2022 09 : 40 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 9/14/2022 09 : 40 AM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 9/15/2022 09 : 40 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 9/16/2022 09 : 40 AM OBSERVED OK

REMARKS : Minor White Rust observed Up to 168 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01

REV. NO. : 02
Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA)
SALT SPRAY TEST REPORT DATE : 15 - 08REV.
- 2022
DATE : 02/12/2021
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 2915 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4179 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 8/2/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 8/15/2022 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 8/3/2022 10 : 15 AM NO WHITE RUST OBSERVED OK

48 Hours 8/4/2022 10 : 15 AM NO WHITE RUST OBSERVED OK

72 Hours 8/5/2022 10 : 15 AM NO WHITE RUST OBSERVED OK

96 Hours 8/6/2022 10 : 15 AM NO WHITE RUST OBSERVED OK

120 Hours 8/7/2022 10 : 15 AM NO WHITE RUST OBSERVED OK

144 Hours 8/8/2022 10 : 15 AM MINOR WHITE RUST OBSERVED BUT NO OK


RED RUST OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
168 Hours 8/9/2022 10 : 15 AM OBSERVED OK
OBSERVATION

192 Hours 8/10/2022 10 : 15 AM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 8/11/2022 10 : 15 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 8/12/2022 10 : 15 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 8/13/2022 10 : 15 AM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 8/14/2022 10 : 15 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 8/15/2022 10 : 15 AM OBSERVED OK

REMARKS : Minor White Rust observed Up to 144 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01

REV. NO. : 02
Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA)
SALT SPRAY TEST REPORT DATE : 17 - 10REV.
- 2022
DATE : 02/12/2021
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 2964 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4192 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 10/4/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 10/17/2022 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 10/5/2022 04 : 40 PM NO WHITE RUST OBSERVED OK

48 Hours 10/6/2022 04 : 40 PM NO WHITE RUST OBSERVED OK

72 Hours 10/7/2022 04 : 40 PM NO WHITE RUST OBSERVED OK

96 Hours 10/8/2022 04 : 40 PM NO WHITE RUST OBSERVED OK

120 Hours 10/9/2022 04 : 40 PM NO WHITE RUST OBSERVED OK

144 Hours 10/10/2022 04 : 40 PM MINOR WHITE RUST OBSERVED BUT NO OK


RED RUST OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
168 Hours 10/11/2022 04 : 40 PM OBSERVED OK
OBSERVATION

192 Hours 10/12/2022 04 : 40 PM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 10/13/2022 04 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 10/14/2022 04 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 10/15/2022 04 : 40 PM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 10/16/2022 04 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 10/17/2022 04 : 40 PM OBSERVED OK

REMARKS : Minor White Rust observed Up to 144 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01

REV. NO. : 02
Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA)
SALT SPRAY TEST REPORT DATE : 24 - 11REV.
- 2022
DATE : 02/12/2021
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 25 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4213 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 11/15/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 11/24/2022 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 11/16/2022 05 : 25 PM NO WHITE RUST OBSERVED OK

48 Hours 11/17/2022 05 : 25 PM NO WHITE RUST OBSERVED OK

72 Hours 11/18/2022 05 : 25 PM NO WHITE RUST OBSERVED OK

96 Hours 11/19/2022 05 : 25 PM NO WHITE RUST OBSERVED OK

OBSERVATION 120 Hours 11/20/2022 05 : 25 PM NO WHITE RUST OBSERVED OK

144 Hours 11/21/2022 05 : 25 PM MINOR WHITE RUST OBSERVED BUT NO OK


RED RUST OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
168 Hours 11/22/2022 05 : 25 PM OBSERVED OK

192 Hours 11/23/2022 05 : 25 PM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 11/24/2022 05 : 25 PM OBSERVED OK

REMARKS : Minor White Rust observed Up to 144 Hours But No Red Rust Observed Up To 196 Hours .Test Discontinue after 198 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .
PREPARED & TESTED BY : APPROVED BY :
MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01
FRM/QA/41
FORMAT NO. :

Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA) REV. NO. : 00
SALT SPRAY TEST REPORT DATE : 05 - 12 - 2022
REV. DATE : 02/12/2022
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 3064 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4222 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 12/22/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 12/5/2022 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 11/23/2022 07 : 00 PM NO WHITE RUST OBSERVED OK

48 Hours 11/24/2022 07 : 00 PM NO WHITE RUST OBSERVED OK

72 Hours 11/25/2022 07 : 00 PM NO WHITE RUST OBSERVED OK

96 Hours 11/26/2022 07 : 00 PM NO WHITE RUST OBSERVED OK

120 Hours 11/27/2022 07 : 00 PM NO WHITE RUST OBSERVED OK

144 Hours 11/28/2022 07 : 00 PM MINOR WHITE RUST OBSERVED BUT NO OK


RED RUST OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
168 Hours 11/29/2022 07 : 00 PM OBSERVED OK
OBSERVATION

192 Hours 11/30/2022 07 : 00 PM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 12/1/2022 07 : 00 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 12/2/2022 07 : 00 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 12/3/2022 07 : 00 PM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 12/4/2022 07 : 00 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 12/5/2022 07 : 00 PM OBSERVED OK

REMARKS : Minor White Rust observed Up to 144 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01
FRM/QA/41
FORMAT NO. :

Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA) REV. NO. : 00
SALT SPRAY TEST REPORT DATE : 16 - 01 - 2023
REV. DATE : 02/12/2022
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 3864 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4234 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 1/3/2022 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 1/16/2023 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 1/4/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

48 Hours 1/5/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

72 Hours 1/6/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

96 Hours 1/7/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

120 Hours 1/8/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

144 Hours 1/9/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

MINOR WHITE RUST OBSERVED BUT NO


168 Hours 1/10/2023 04 : 40 PM RED RUST OBSERVED OK
OBSERVATION

192 Hours 1/11/2023 04 : 40 PM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 1/12/2023 04 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 1/13/2023 04 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 1/14/2023 04 : 40 PM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 1/15/2023 04 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 1/16/2023 04 : 40 PM OBSERVED OK

REMARKS : Minor White Rust observed Up to 168 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01
FRM/QA/41
FORMAT NO. :

Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA) REV. NO. : 00
SALT SPRAY TEST REPORT DATE : 17 - 02 - 2023
REV. DATE : 02/12/2022
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 3464 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4247 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 2/4/2023 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 2/17/2023 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 2/5/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

48 Hours 2/6/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

72 Hours 2/7/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

96 Hours 2/8/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

120 Hours 2/9/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

144 Hours 2/10/2023 04 : 40 PM NO WHITE RUST OBSERVED OK

MINOR WHITE RUST OBSERVED BUT NO


168 Hours 2/11/2023 04 : 40 PM RED RUST OBSERVED OK
OBSERVATION

192 Hours 2/12/2023 04 : 40 PM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 2/13/2023 04 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 2/14/2023 04 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 2/15/2023 04 : 40 PM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 2/16/2023 04 : 40 PM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 2/17/2023 04 : 40 PM OBSERVED OK

REMARKS : Minor White Rust observed Up to 168 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01
FRM/QA/41
FORMAT NO. :

Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA) REV. NO. : 00
SALT SPRAY TEST REPORT DATE : 10 - 03 - 2023
REV. DATE : 02/12/2022
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 325 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4259 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 2/25/2023 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 3/10/2023 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 2/26/2023 10 : 45 AM NO WHITE RUST OBSERVED OK

48 Hours 2/27/2023 10 : 45 AM NO WHITE RUST OBSERVED OK

72 Hours 2/28/2023 10 : 45 AM NO WHITE RUST OBSERVED OK

96 Hours 3/1/2023 10 : 45 AM NO WHITE RUST OBSERVED OK

120 Hours 3/2/2023 10 : 45 AM NO WHITE RUST OBSERVED OK

144 Hours 3/3/2023 10 : 45 AM NO WHITE RUST OBSERVED OK

MINOR WHITE RUST OBSERVED BUT NO


168 Hours 3/4/2023 10 : 45 AM RED RUST OBSERVED OK
OBSERVATION

192 Hours 3/5/2023 10 : 45 AM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 3/6/2023 10 : 45 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 3/7/2023 10 : 45 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 3/8/2023 10 : 45 AM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 3/9/2023 10 : 45 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 3/10/2023 10 : 45 AM OBSERVED OK

REMARKS : Minor White Rust observed Up to 168 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01
FRM/QA/41
FORMAT NO. :

Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA) REV. NO. : 00
SALT SPRAY TEST REPORT DATE : 16 - 04 - 2023
REV. DATE : 02/12/2022
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 2464 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4274 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 4/3/2023 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 4/16/2023 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 4/4/2023 10 : 15 AM NO WHITE RUST OBSERVED OK

48 Hours 4/5/2023 10 : 15 AM NO WHITE RUST OBSERVED OK

72 Hours 4/6/2023 10 : 15 AM NO WHITE RUST OBSERVED OK

96 Hours 4/7/2023 10 : 15 AM NO WHITE RUST OBSERVED OK

120 Hours 4/8/2023 10 : 15 AM NO WHITE RUST OBSERVED OK

144 Hours 4/9/2023 10 : 15 AM NO WHITE RUST OBSERVED OK

MINOR WHITE RUST OBSERVED BUT NO


168 Hours 4/10/2023 10 : 15 AM RED RUST OBSERVED OK
OBSERVATION

192 Hours 4/11/2023 10 : 15 AM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 4/12/2023 10 : 15 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 4/13/2023 10 : 15 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 4/14/2023 10 : 15 AM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 4/15/2023 10 : 15 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 4/16/2023 10 : 15 AM OBSERVED OK

REMARKS : Minor White Rust observed Up to 168 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ
ELECTROCOATS DOC. NO. : SST/01
FRM/QA/41
FORMAT NO. :

Plot No. 42, Sector - 4 Ind. Area, Faridabad (HARYANA) REV. NO. : 00
SALT SPRAY TEST REPORT DATE : 17 - 05 - 2023
REV. DATE : 02/12/2022
CUSTOMER NAME PREMIER RUBBER INDUSTRIES STANDARD FOR SALT SPRAY TEST
PART NAME / NO. 1064 TEMPERATURE (35 ± 2)⁰ C
IDENTIFICATION MARK S. NO. - 4288 FOG COLLECTION 1-2 Ml/ Hour
PLATING THICKNESS 8-12 µ pH 6.5 - 7.2
PLATING TRIVALENT ZINC AIR PRESSURE 0.1 - 0.2 MPA
TEST START DATE 5/4/2023 SOLUTION 5 % NaCl OF D-M.WATER
TEST ENDED DATE 5/17/2023 ANGLE 45⁰
SALT SPRAY TEST LIFE AS PER
CUSTOMER STANDARD 120 HOURS FOR WHITE RUST & 305 HOURS FOR RED RUST AS PER CUSTOMER STANDARD

TIME COVERED DATE TIME OBSERVATION REMARKS

24 Hours 5/5/2023 11 : 35 AM NO WHITE RUST OBSERVED OK

48 Hours 5/6/2023 11 : 35 AM NO WHITE RUST OBSERVED OK

72 Hours 5/7/2023 11 : 35 AM NO WHITE RUST OBSERVED OK

96 Hours 5/8/2023 11 : 35 AM NO WHITE RUST OBSERVED OK

120 Hours 5/9/2023 11 : 35 AM NO WHITE RUST OBSERVED OK

144 Hours 5/10/2023 11 : 35 AM NO WHITE RUST OBSERVED OK

MINOR WHITE RUST OBSERVED BUT NO


168 Hours 5/11/2023 11 : 35 AM RED RUST OBSERVED OK
OBSERVATION

192 Hours 5/12/2023 11 : 35 AM WHITE RUST OBSERVED BUT NO RED RUST OK


OBSERVED
WHITE RUST OBSERVED BUT NO RED RUST
216 Hours 5/13/2023 11 : 35 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


240 Hours 5/14/2023 11 : 35 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


264 Hours 5/15/2023 11 : 35 AM OBSERVED OK
WHITE RUST OBSERVED BUT NO RED RUST
288 Hours 5/16/2023 11 : 35 AM OBSERVED OK

WHITE RUST OBSERVED BUT NO RED RUST


312 Hours 5/17/2023 11 : 35 AM OBSERVED OK

REMARKS : Minor White Rust observed Up to 168 Hours But No Red Rust Observed Up To 305 Hours .Test Discontinue after 308 Hours (End)

NOTE : TEST ARE FOLLOWED & PERFORMED AS PER ASTM - B117 STANDARD .

PREPARED & TESTED BY : APPROVED BY :


MR. KRISHNA MR. SATISH BHARDWAJ