Professional Documents
Culture Documents
PRIMUS
ULTIMATE WHOLE BODY DXA
FOR EVERYONE
Ver. OT-2019-001
Ver. OT-2019-001
Contents
02 OSTEOSYS
06 PRIMUS
GENERAL SPEC.
TECH SPEC. IN DETAIL
LOCKING OUT APPLICATION
22 SAMPLE REPORT
39 ROOM LAYOUT
MISSION & CORE VALUE
Passi
on
Tru s t
io n
at
02 03
ov
Inn
MISSION & CORE VALUE
INTRODUCTION OF OSTEOSYS
FULL LINEUP MISSION
Better Products for Better Life
PASSION
Passion is the driving force and one of the prerequisites for achieving our goal.
We try to reach our goal through an efficient cooperation with talented employees
who have the passion and responsibility fortheir mission.
INNOVATION
In order to meet our customer’s satisfaction, we produce more effective and
differentiated product through the innovation which is impetus of the foundation of
company growth together with passion.
TRUST
We operate the company by honest and transparent management which is based
on the trust. OsteoSys strives for creation of win-win corporate culture of good
circulation.
INTRODUCTION OF OSTEOSYS FULL LINEUP
SONOST SONOST
BeeTLe EXA 3000 EXA Presto DEXXUM T EXCELLUS PRIMUS
2000 3000
04 QUS ̻ ̻ ̻ 05
≊ Established in 2000
≊
Products Installation
≊DXA BMD system : About 6,000 installation base (Dec, 2018) Peripheral ̻ ̻ ̻ ̻ ̻
≊QUS BMD System : About 10,000 installation base (Dec, 2018)
≊
70+ employees worldwide (R&D 30)
≊$15 Million of revenue in 2018
Central ̻ ̻
≊130 distributors in global market
≊
Headquarters in Guro-gu,Seoul, South KOREA Whole Body ̻
≊Chinese corporation in Shanghai (Established in 2012)
≊www.osteosys.com
Cone Beam ̻ ̻
2015 Launched 1st Gen. Half body Fan beam DXA DXA ̻ ̻ ̻ ̻ ̻
2013 Launched 1st Gen. Whole body DXA (with Body composition& Assessment)
2008 Launched 2nd Gen. Pencil beam DXA (compact design & fold wing bed Down)
2005 Launched 1st Central DXA (First pencil beam table type DXA)
GENERAL SPEC.
Ver. OT-2019-001
Component Parameter Spec.
Type Whole Body DXA (with total body composition)
Method Narrow fast Fan-beam
Principle Dual-energy X-ray Absorptiometry scan
APSpine(L1-L4), Femur, Dual Femur, Forearm, Lateral,
Scan Site VFA(LVA, APVA), TotalBody, Infant, Othopedics(Prosthesis Hip),
Prosthesis Knee, Hand, Animal, Study(Free Region)
Scanning Method Rectilinear scan
Reproducibility ⴍ 1.0% CV.
BMD Precision (in vitro & in vivo) < 1.0%
Reference Age (infant : 0-3, pediatric : 4-19, adult : 20 ~ 99)
Clinical Parameters Input age (0-150), Patient weigt supported: 0 ~ 210kg
(Max. patient weight for software : 150kg)
Automatic Calibration Available with daily calibration phantom
Measure Time
Output Frequency DC
≊Power consumption : 110VAC / 220VAC(+/-10%)
Aluminum Equivalent 0.5 mmAL Free Distance between the Arm and
440mm
Table (for lateral scan)
Maximum Useful Volltage 120 kV
Compact Table Available (2284mm x 1040mm x 1250mm: Short Body)
X-ray Tube Maximum Filament Current 4A Manufacturer SAMSUNG/HP
Nominal Focal Sspot Values
0.5mm x 0.5mm CPU ⴎ Intel Pentium Gold G5400 3.7 2400MHz 2C 54W CPU
(x-ray point dimension)
Maximum Symmetrical Radiation Field 60mm x 8mm AM ⴎ 4 GB
Tube Angle 5ⰻ HDD ⴎ 500GB
Monitor ⴎ 1366 x 768
Focal Spot Size 0.5mm x 0.5mm = 0.25mm^2
Workstation (PC) CD ROM CD / DVD R/W drive
Focal Spot to Image Receiptor Distance 662mm
Communicaiton Ethernet TCP/IP
Focal Spot to Pad Surface Distance 200mm (pad surface = table top) Graphic Intel HD Graphics Shared
Focal Spot to Table Top Distance 200mm OS ⴎ Windows 7
Focal Spot to Colimator Distance 100mm POWER 110 ~ 240 VAC , 50 / 60 Hz
Anode Angle 5ⰻ Skin Enterance Dose indication Available (uGy and uSv)
Anode-Cathode Direction Horizontal AP Spine : ⴍ7.52 uGy
Femur : ⴍ8.28 uGy
Focal Point Dimension 0.043 = Focal spot 0.5mm x Sin 5ⰻ= 0.5 x 0.0871 Patient Radiation Dose
Forearm : ⴍ2.06 uGy
Anode Capacity 42kHU Safety Total Body : ⴍ0.55 uGy
Housing Tube Thermal Capacity 271KHU = 83kV x 3mA x 780sec x 1.4 HIP < 0.341uSv (1mA)
Leakage Radiation Dose Dual Femur < 0.682uSv (1mA)
Tube Cooling Insulation oil
Spine < 0.341uSv (1mA)
Target Angle 5ⰻ Forearm < 0.173uSv (0.2mA)
Type of Collimator/Material 1st : Copper, 2nd: Lead Accessory Positioning Supporters Lateral Positioner, Lateral Positioner Cushion, Foot Guide
Collimator Height 48mm Daily QC Phantom is offered as
QC Available
acceesory
Distance from Collimator to Patient 100mm
Humidity 30% ~ 75%
Distance from Tube to Patient 200mm
External Shielding Not Required
Shutter Minimum Lead 8.07mm(AL : 6 mm, Lead 2mm, Copper 0.07mm)
Temperature 10Ⳅ~40Ⳅ
Shutter Size 30mm x 58mm x 8mm (W x D x H) Storage Temperature 5Ⳅ~50Ⳅ
X-ray Collimator
Total Filteration 4.3mm Aluminium (Al) 2.5mmAl Environmental Power Consumption 700VA
Diameter 16.5mm x 4mm Requirement Input Power 110VAC / 220VAC +/- 10%
SOD(Source to Object Distance) 200mm Shock and Vibration 700 ~ 1060hPa
SID(Source to Inspecctor Distance) 662mm Emergency function
OID(Object to Inspector Distance) 462mm (key or button on the control console to
Available initiate stop scanning)
X-ray Filter Control K-edge filter / Samarium Foil
Ver. OT-2019-001 Ver. OT-2019-001
Component Parameter Spec. Component Parameter Spec.
AP spine Measurement and Analysis Available Multimedia Online Help Available (remote control service)
Femur Measurement and Analysis Available Superior Fracture Risk
Available (APVA)
Orthopedics Knee Measurement and Assessment (VFA)
Available
Analysis Hand for Monitoring Rheumatoid
Available (study mode for imaging diagnosis purpose)
Othopedics(Prosthesis Hip) Arthritis
Available
Measurement and Analysis Multiple Patient Directories Available
Total Body Measurement and Analysis Available Data Correction available
Regional Body Measurement and Database Conversion Available
Available
Analysis Management Tool Available
Forearm Measurement and Analysis Available Importatoin of Previous Exam for
Lateral Spine Measurement and Analysis Available Available
Individual Patient
VFA(LVA, DVA) Measurement and
Available Importation of Entire Database Available
Analysis
Combined Report & Scan Protocols Available
Whole Body Composition Available
VAT(Visceral Adipose Tissue) Available Automated QA Trending Available
Programs (S/W) Analysis for Customized Region Of
Infant Measurement and Analysis Available Available
Digital Vertebral Assessment Available Interest
Pediatric Spine, Femur, Total Body
Study Mode Available Available
Measurement
Vertebral Assessment (L4-T4) Available Small Animal Totalbody Measurement
Pediatrics Available Available
and Analysis
AFF Available Automatic Metal Detection Available
Hand Available Image Preview Available
Hip Analysis Available
Comparability of Examination Available
Morphometric Tools for Femur Available (Hip Axis Length : HAL, Hip Angle : HA)
Automatic Mean Cortical Thickness Available (manual function)
Scoliosis Available
Femoral Neck Band Available (Medial, Lateral)
Kyphosis Available
12 Colour Mapping Available Subtrochannic Band Available (Medial, Lateral) 13
Trend Analysis Trochanter Band Available (Medial, Lateral)
Available Chinese, English, French, Germany, Italian, Kazahstan, Korean,
(BMD, Body Composition, Scan Image) Multi-language
B-Scope (Body Scope) Available Persian, Polish, Portuguese, Russian, Spanish, Thai, Turkish, Vietnam
FRAX Available AP Spine 160mm x 189mm
Ergonomic Scan Available Fermur 120mm x 147mm
Zone of Interest Available Total body 580mm x 1995mm
Auto ROI Available Forearm 100mm x 144mm
Angle ROI (Manual) Available Lateral Spine 140mm x 216mm
Angle Adjustment Available Infant 160mm x 160mm
Programs (S/W) Brush Function Available Study 160mm x 160mm
Edge Auto Detection Available Orthopedics 120mm x 224mm
Implant Auto Detection Available
VFA(LVA, DVA) 240mm x 420mm
Automatic Real One-Scan Available
Scan Area Forearm UD(Ultradistal), MID(mid-distal), 33%(1/3) Point
Re-Scan Available
Dual Energy Image Inspection Hip Neck, Wards, Troch, Shaft(intertrochanter), Total
Available Dual Scan: Combined examination of
(Low Energy & High Energy) Available
Compare Function Available the left and right hip
One Scan: Combined examination of the
Archive System Available Available
lumbar spine and of the left and right hip.
Data Back Up & Restore Available (With GE Data Only)
Total and Local (Head, Spine, left Rib, left Arm, left Leg, left Total,
Ver1 : Mideast, Asian, White, Black, Hispanic, Italian, Chinese, Whole Body Scan
right Rib, right Arm, right Leg, right Total, Peivis)
Australia, Korean, Sapin, European, USA_White, USA_Asian, Lateral Spine BMD Available
USA_Hispanic, USA_Black, NHANES_Asian, NHANES_Black, Available
NHANES_Hispanic, NHANES_White, Turkey_Asian, Turkey_Black, Pediatrics BMD and Z-score for AP spine and Femur, Whole Body
Reference Population
Turkey_Hispanic, Turkey_White Composition
Ver 2 : Asia, Australia, Brazil, China, Egypt, France, Finland, Modality Worklist Available
Germany, Indonesia, Italy, Japan, Korea, Mexico, Middle East, DICOM 3.0 Storage Class Available
Philippine, Spain, Tunisia, Turkey, USA, USA(NHANES), UK
DICOM 3.0 Worklist Available
Supported with LVA(Lateral Vertebral Assessment), Scoliosis,
Advanced Morphometric Tools DICOM 3.0 Image Format in DICOM, JPEG and TIFF Available
Kyphosis
Body Composition Available (BMI, Android / Gynoid Ratio) Send(Storage) Available
Detecting Function for Atypical Femoral Cross calibration between the new
Available Available
Fracture(AFF) system and the existing system
Exclusion of Non-Bone Region from Regirstration CE, CFDA, ANVISA, ISO13485 : 2016, ISO9001 : 2015
Available
calculation (metal, calcification, etc.) Medical Devices Registration Must submit ISO 13485 : 2003 / AC : 2007
Orthopedics with Peri-Prosthetic Bone IEC60601-1 : 2005(Medical electrical equipment - Part 1 :
Available (Orthopedics, Prosthesis Hip, Prosthesis Knee)
Density Analysis (hip prosthesis). General requirements for basic safety and essential performance)
Spine Geometry Available (Scoliosis, Kyphosis) IEC60601-1-2 : 2007(Medical electrical equipment - Part 1-2 :
Patient's trend/curve comparison process: General requirements for safety - Collateral Standard:
short-term change, long-term change, Available Electromagnetic compatibility)
Certificate
change expressed in% and% per year. General Requirements of Safety for IEC60601-1-3 : 2008(Medical electrical equipment - Part 1-3 :
Detailed colour print out of reports Available Electromagnetic Compatibility General requirements for safety - Collateral standard: General
Calcic Mass Available (BMC Available) requirements for radiation protection in diagnostic X-ray
Exposure Audio & Visual indication Available equipment)
Automatic metal detection Available IEC60601-2-28:2010(Medical electrical equipment - Part 2 :
Automated WHO Background Particular requirements for the safety of X-ray source assemblies
Available
evaluation and X-ray tube assemblies for medical diagnosis)
LOCKING OUT APPLICATION
Locking Out Application #1 : Color Mapping Mode (RCM, BCM, OCM) Locking Out Application #2 : L (Line)-Scope
14 15
BMD analysis by L-Scope
RCM
OCM
B-Scope is OsteoSys’ revolutionary function to offer micro analysis of body FIM(Fat in Muscle) is a special tool for diagnosis of Sarcopenia.
composition(bone, lean, fat) for any ROI you choose. Three major standards for diagnosis of Sarcopenia are muscle mass, strength,
physical performance.
B-Scope is the optimal solution for post-op treatment of liposuction surgery, diagnosis / Many studies prove that muscle quality should be seriously considered
treatment of Lymph-edema and sarcopenia. for better diagnosis. Even if you have same muscle mass, the quality of
muscle decrease according to the amount of fat mass in muscle.
FIM function is OsteoSys’ exclusive application to assess muscle quality.
16 17
Agea 25 Age 63
Locking Out Application #5 : Animal Mode
Spine Scan
Cyno
18
RESEARCH 19
Femur Scan
●
Anorexia nervosa The relationship between Rehabilitation Baker Norton
BMD, Body Composition bone mineral density and Berlex Laboratories
Orthopedics
●
Chrohn’s disease Analysis(Lean Mass) body composition with Boenringe
Gastrointestinal disorders Celiac disease vertebral fragility fractures. Endoscopy
●
Bristol-Myers Squibb
●
Gastrectomy 6 Diagnosis Center Rheumatoid Arthritis Bone Care International
Body Composition Analysis Sarcopenia and frailty Ob/Gyn Chugai
●
Cirrhosis (Lean Mass) guidelines update. CEPA
Hepatobiliary disorders Internal Medicine
●
Gallstones Chinoin
The relationship between DIC(Disseminated Intravascular Chugai Pharmaceutical
●
Chronic renal failure t-cell responses to Coagulopathy) Elan (HSRI)
Renal disorders Hemodialysis Body Composition Analysis cytomegalovirus(cmv) and E. Tosse
Bisphosphonate manufactures Alendronate
●
Measurement Results
PatientID 1 BirthDate 1980-06-06 (38.6) Height 165.0 cm
SAMPLE
Analysis of Lumber spine
Region BMD (g/ ⽊ ) T-Score Z-Score BMC (g) Area (⽊) Regional density value curve(g/c⽋)
REPORT
1.26
L4 1.116 -0.7(93%) -0.7(93%) 17.73 15.89
L3-L4 1.107 -0.8(92%) -0.8(92%) 33.91 30.63 Image not for diagnosis Reference curve Region of Interest
Osteoporosis *BMI -
0.60 -5
20 30 40 50 60 70 80 90 100 Me
Age(years)
Index of treatment boundary
45
Follow up examnination
40
165.0 Comparision between current and
Height (cm)
previous BMD value 35
55.0 3.00 30
Weight (kg)
25
20 Fracture
over 20% Treatment
BMI (kg/༇) probability %
20
0.33
1.032 15
BMD (g/c༇)
10
-1.3
T-Score -2.33
5 over 3% Treatment
-1.3
Z-Score 0
40 45 50 55 60 65 70 75 80 85 90
-5.00 Age
Hip Main part
ScanDate 17.08.23 17.08.23
Doctor Name
Dr.Demo
Measurement Results
PatientID 1 BirthDate 1980-06-06 (38.6) Height 165.0 cm
0.82 2
Analysis of both sides Femur
0.71 1
0.60 0
L2
Normal
0.49 -1
24 0.38
Osteopenia
-2 25
0.27 -3
0.17 -4
L3 0.06
Osteoporosis
-5
20 30 40 50 60 70 80 90 100
R ight Femur Image not for diagnosis Image not for diagnosis Left F emur Region BMD (g/⽊) T-Score Z-Score BMC (g Area ( ⽊)
T-Score & Z-Score Prediction of future fracture L4 L2 1.084 4.4 (180%) 4.4 (180%) 11.68 10.77
1.20 1 Neck Left 0.893 -1.2(84%) -0.7(90%) L4 0.814 1.4 (123%) 1.4 (123%) 6.29 7.72
Right Femur
Neck Mean 1.050 -0.1(99%) 0.4(106%)
1.06 0 *When BMD value of Femur is input L2-L3 1.038 4.0 (173%) 4.0 (173%) 18.34 17.68
Normal Neck Diff. 0.313 Under... Under... Major osteoporotic fracture probability -
0.93 -1
Total Right 1.146 1.0(113%) 1.3(116%) Probability of Hip Fracture -
Left Femur L2-L4 0.970 - - 24.63 25.40
0.79 Osteopenia -2
Total Left 0.988 -0.2(97%) 0.0(100%) When BMD value of Femur is not input
- L3-L4 0.885 2.4 (141%) 2.4 (141%) 12.95 14.63
0.65 -3 Total Mean 1.067 0.4(105%) 0.7(108%) Major osteoporotic fracture probability
Image not for diagnosis
Probability of Hip Fracture -
0.52 -4 Total Diff. 0.158 Under... -6.7(16%)
Osteoporosis *BMI -
0.38 -5
1.236
1.206 10
BMD (g/c⽋) BMD (g/c⽋) 0.893
over 3% Treatment
2.2 5
2.0
T-Score T-Score -0.4 0
ASIAN, Reference Population.
2.5 40 45 50 55 60 65 70 75 80 85 90 According to the publication of the World Health Organization(WHO)
2.3 Age - Normal : A BMD result not more than 1SD below the young adult mean(T ≥ -1.0) is considered normal.
Z-Score Z-Score -0.1 Hip Main part
- Osteopenia : A BMD result that lies between 1.0 and 2.5SD below the young adult mean(-1.0 > T > -2.5) indicates osteopenia.
- Osteoporosis : A BMD result more than 2.5SD below the young adult mean(T ≤ -2.5) is classified as osteoporosis.
ScanDate 17.08.23 ScanDate 17.08.23 17.08.23
Normal : T ≥ -1.0
Osteopenia : -1.0 > T > -2.5
Osteoporosis : T ≤ -2.5
Doctor's comment Doctor's information
Operating department
Osteosys
Doctor Name
Dr.Demo
Version: 1.2.1 MN: 121.01.29 PRIMUS / OSTEOSYS
04. Forearm 05. LVA
Measurement Results
PatientID 1 BirthDate 1980-06-06 (38.6) Height 165.0 cm
Osteoporosis *BMI -
0.31 -5
20 30 40 50 60 70 80 90 100 Me
Age(years)
Index of treatment boundary Comment
45
Follow up examnination
40
165.0 Comparision between current and
Height (cm)
previous BMD value 35
55.0 3.00 30
Weight (kg)
25
20 Fracture
over 20% Treatment
BMI (kg/༇) probability %
20
0.33
0.617 15
BMD (g/c༇)
10
1.4
T-Score -2.33
5 over 3% Treatment
Doctor Name
Dr.Demo
Measurement Results
PatientID 1 BirthDate 1980-06-06 (38.6) Height 180.0 cm
Patient Information
Total Body Site Analysis
PatientID.........................................1 Doctor................................Dr.Demo 1. Total Body Scan Image 2. Total Body Composition (kg)
Name.....................................Patient Ethnicity.................................ASIAN Value Soft Tissue Body Weight
BirthDate.............1980-06-06 (38.6) Gender......................................Male
Total Lean Mass 59.4
Height................................180.0 cm Weight................................120.0 k g 113.1
Total Fat Mass 53.7 116.9
Fragility Fractures........................No
Total Bone Mass 3.8
TotalBody
PM_T-B_-VA 3. Body Fat Analysis
BMI PBF(F/W)*100 47.5
VAT Mass (g) 1849
Under Weight Normal Over Weight Obese - 1 Obese - 2
VAT Volume ( ) 2010
VAT Area (༆) 372
1 2 3 4 5
5 VAT (%) / SAT (%) 34 / 26
Region Fat (g) Lean (g) TISSUE (g) BMC (g) Total (g) BMC(%) TissueFAT(%) TotalFAT(%)
Head 2277 4383 6660 637 7298 8.7 34.2 31.2
5. BMI
L-Arm 1705 1795 3500 97 3596 2.7 48.7 47.4
BMI : 37.0%
L-Trunk 14758 14911 29669 909 30578 3.0 49.7 48.3
Under Weight Normal Over Weight Obese - 1 Obese - 2
L-Leg 9385 11175 20560 591 21151 2.8 45.6 44.4
L-Total 26987 30073 57059 1915 58974 3.2 47.3 45.8 1 2 3 4 5
R-Arm 1520 1607 3128 82 3210 2.6 48.6 47.4 18.5 25.0 30.0 35.0
Image not for diagnosis
R-Trunk 14412 14445 28857 889 29746 3.0 49.9 48.4
R-Leg 9624 11118 20742 593 21335 2.8 46.4 45.1
R-Total 26695 29362 56057 1883 57940 3.2 47.6 46.1
Total 53682 59435 113116 3798 116914 3.2 47.5 45.9
6. Body Map 7. Trend
Android 5891 3891 9782 138 9920 1.4 60.2 59.4
Gynoid 8636 8501 17137 373 17510 2.1 50.4 49.3 Obesity
Appen.LM Lean(g) 25694.7
ScanDate 17.08.23
BF : Body Fat
ASIAN, Reference Population. A : AWGS, Asian Working Group for Sarcopenia
I : IWGS, International Working Group for Sarcopenia
According to the publication of the World Health Organization(WHO) E : EWGS, European Working Group for Sarcopenia
- Normal : A BMD result not more than 1SD below the young adult mean(T ≥ -1.0) is considered normal. Normal A I E Muscle weekness
- Osteopenia : A BMD result that lies between 1.0 and 2.5SD below the young adult mean(-1.0 > T > -2.5) indicates osteopenia.
- Osteoporosis : A BMD result more than 2.5SD below the young adult mean(T ≤ -2.5) is classified as osteoporosis.
Normal : T ≥ -1.0
Osteopenia : -1.0 > T > -2.5 Doctor's comment Doctor's information
Osteoporosis : T ≤ -2.5
Operating department
Osteosys
Doctor Name
Dr.Demo
1.500 2.258
1.380 2.138
2017-08-23 2017-08-23
1.260 2.018
1.140 1.898
32 Z1
33
Z7
1.020 1.778
0.900 1.658
Z2 Z6
Z3 Z5 Z1
Region BMD(g/⽊) BMC(g) Area(⽊) Fat(g) Lean(g) Total(g) FAT(%) Region BMD(g/⽊) BMC(g) Area(⽊) Fat(g) Lean(g) Total(g) FAT(%)
Zone 1 1.260 4.926 3.910 23.407 114.732 143.064 16.806 Zone 1 2.018 28.340 14.045 857.405 1117.860 2003.604 46.777
Z4
Zone 2 0.998 0.473 0.474 37.150 182.898 220.521 16.721 Zone 2 - - - - - - -
Zone 3 - - - 44.234 182.823 227.057 19.353 Z3 Zone 3 1.742 26.120 14.992 548.026 827.026 1401.173 43.203
Comment Comment
10. APVA 11. Infant Total body
T4 T4
T5
34 T7
35
T7
Comment Comment
Measurement Results
PatientID 1 BirthDate 1966-06-06 (52.5) Height 166.0 cm
Patient Name Patient Gender Female Weight 66.0 kg
PrintDate : 2019-01-28 Ethnicity TURKEY_WHITE Date Measured2017-08-23
Patient Information
VAT Analysis
PatientID.........................................1 Doctor................................Dr.Demo 1. VAT(Visceral Adiopose Tissue) / Visceral Fat
Name.....................................Patient Ethnicity................................WHITE VAT Scan estimates the VAT (Visceral Adipose Tissue)
BirthDate.............1980-06-06 (38.6) Gender.................................F emale content within the android region, VAT is a specific type
of fat that is associated with several types of metabolic
Height................................165.0 cm Weight..................................65.0 k g diseases such as obesity, metabolic syndrome, and type
Menopause..................................No F ragility F ractures........................No 2 diabetes. CoreScan results have been validated for
adults between ages 18-90, and with a BMI in the range
of 18.5-40
Knee
PM_K-ne-e. 1.247 Zone 1 BMD Visceral Fat(VAT)
1.127
1.007
2. Body Fat Analysis
2017-08-23
0.887 PBF(F/W)*100 47.1
VAT Mass (g) 1541
0.767
36 38 VAT Volume ( ⽎ ) 1675 37
Z3 Z5 0.647 Approx. VAT Area (༆) 310
VAT (%) / SAT (%) 29 / 31
0.527
Z1 Z2
ScanDate 17.08.23
Doctor Name
Demo
Measurement Results
PatientID 1 BirthDate 1980-06-06 (38.6) Height 165.0 cm
Analysis of AFF
1. AFF(Atypical Femoral Fracture) 2. AFF Location & Width(mm)
38
Region
Line 1
Line 2
Line 3
Location (mm)
303
326
155
Width (mm)
7.9
7.8
6.7
ROOM 39
LAYOUT
Line 4 230 6.6
Line 5 172 7.2
Line 6 209 6.9
Line 7 256 6.9
ScanDate 17-08-23
4. Trend
Doctor Name
Dr.Demo
PRIMUS
40
3000
2790
SEOUL OFFICE
Address: 9F, 903 JNK DIGITAL TOWER, 111 DIGITAL-RO 26, GURO-GU, SEOUL, KOREA
Phone : +82 2 6124 5900
E-mail : info@osteosys.com
Homepage : www.osteosys.com
Facebook : https://www.facebook.com/worldtopbmd/