1) Source: LED
Distance= 6km
Sensitivity= -42dBm
Ptx= -13dBm
Fiber attenuation=3.5dB/km
Connector insertion loss= 1dB. We have two connectors
Margin= 6dB
Power link budget and rise time budget for RZ and NRZ.
Power budget
Prx= -13dBm – 21dB -2dB -6dB = -42dBm Prx>= sensitivity with margin
Prx = -36 dBm without considering the margin. Prx > sensitivity
Tsys=
Ttx= 15ns, Tmat= 0.07ns/(nm*km) * 40nm * 6km = 16.8 ns , Tmod= (0.44*6)0.7/ 400 = 4.93 ns
For NRZ
t sys < 70 % tb , t sys < 0.7tb tb= 38.52ns , then maximum bit rate= 1/38.52ns = 25.96Mbps
For RZ
t sys < 35 % tb , t sys < 0.35tb tb= 77.05ns, then maximum bit rate = 12.95 Mbps.
2)
Length: 30Km
fiber attn: 0.5 dB/km
Coupled laser diode output -2 dBm
APD sensitivity at 2.5 Gbps -32 dBm
Splice loss= 0.1 dB
Connector loss: 0.6 dB
Roll length= 5Km
Margin =6dB
■ A laser transmitter with a 0.1-ns rise time and a 1.0-nm spectral width
■ An APD receiver with a front-end bandwidth B RX ⫽ 2500 MHz
■ A G.655 single-mode fiber with D CD ⫽ 4 ps/(nm⫽km) a
Power budget
Ptx= -2bm, FiberAttn= (0.5 dB/km)* 30Km = 15 dB , ConnectorLoss= 1.2dB, Spliceloss= 5*0.1dB =
0.5dB, Margin= 6dB
Prx= -2dBm – 15dB -1.2dB - 0.5dB - 6dB = -24.7dBm Prx>= sensitivity with margin
Prx = -18.7 dBm without considering the margin. Prx > sensitivity
Tsys=
For NRZ
t sys < 70 % tb , t sys < 0.7tb .
For RZ
It does not work because tsys > 0.35tb, 0.2ns > 0.14ns