Type 1.1 – Grid+Battery, 6h BBT, Pc < 5kW, non-hub (Cost optimized rectifier number)

PSU – 1
Battery cabinet – 0
Rectifier units – 4
Batteries – 4
DG set – 0
ACDB – 1

FCOB

BTS, TX

Grid
ACDB

PSU

2 © 2022 Nokia Confidential


Type 1.2 – Grid+Battery, 6h BBT, Pc > 5kW, non-hub (Cost optimized rectifier number)

PSU – 1
Battery cabinet – 0
Rectifier units – 4
Batteries – 5
DG set – 0
ACDB – 1

FCOB

BTS, TX

Grid
ACDB

PSU

3 © 2022 Nokia Confidential


Type 1.3 – Grid+Battery, 8h BBT, Pc < 5kW, non-hub
PSU – 1
Battery cabinet – 1
Rectifier units – 6
Batteries – 5
DG set – 0
ACDB – 1

FCOB

BTS, TX

Grid
ACDB

PSU

4 © 2022 Nokia Confidential


Type 1.4 – Grid+Battery, 8h BBT, Pc > 5kW, non-hub
PSU – 1
Battery cabinet – 1
Rectifier units – 6
Batteries – 7
DG set – 0
ACDB – 1

FCOB

BTS, TX

Grid
ACDB

Bat.Cabinet PSU

5 © 2022 Nokia Confidential


Type 2.1 – Grid+DG+Battery, 6h BBT, Pc < 5kW, hub (Cost optimized rectifier number)

PSU – 1
Battery cabinet – 0
Rectifier units – 4
Batteries – 4
DG set – 1
ACDB – 1

FCOB
Grid

BTS, TX

ACDB
Genset 30 KVA
PSU

6 © 2022 Nokia Confidential


Type 2.2 – Grid+DG+Battery, 6h BBT, Pc > 5kW, hub (Cost optimized rectifier number)

PSU – 1
Battery cabinet – 0
Rectifier units – 4
Batteries – 5
DG set – 1
ACDB – 1

FCOB
Grid

BTS, TX

ACDB
Genset 30 KVA
PSU

7 © 2022 Nokia Confidential


Type 2.3 – Grid+DG+Battery, 8h BBT, Pc < 5kW, hub
PSU – 1
Battery cabinet – 0
Rectifier units – 6
Batteries – 5
DG set – 1
ACDB – 1

FCOB

Grid
BTS, TX

ACDB
Genset 30 KVA
PSU

8 © 2022 Nokia Confidential


Type 2.4 – Grid+DG+Battery, 8h BBT, Pc > 5kW, hub
PSU – 1
Battery cabinet – 1
Rectifier units – 6
Batteries – 7
DG set – 1
ACDB – 1

FCOB

Grid
BTS, TX

ACDB
Genset 30 KVA
Bat.Cabinet PSU

9 © 2022 Nokia Confidential


Type 3.1 – Solar+DG+Battery, 24h BBT, Pc < 5kW, non-hub (Cost optimized battery number)
PSU – 1
Battery cabinet – 2
Rectifier units – 6
Solar Rectifier units – 3
Solar Panels – 18
Batteries – 11
DG set – 1
ACDB – 1

FCOB

BTS, TX

ACDB
Genset 30 KVA
Bat.Cabinet PSU
Confidential

10 © 2022 Nokia
Type 3.2 – Solar+DG+Battery, 24h BBT, Pc > 5kW, non-hub / hub
PSU – 1
Battery cabinet – 1
Rectifier units – 6
Solar Rectifier units – 4
Solar Panels – 32
Batteries – 16
DG set – 1
ACDB – 1

FCOB

BTS, TX

ACDB
Genset 30 KVA
Bat.Cabinet Bat.Cabinet PSU
Confidential

11 © 2022 Nokia
Type 3.3 – DG+Battery, 24h BBT, Pc > 5kW, non-hub / hub – (Optional configuration)
PSU – 1
Battery cabinet – 2
Rectifier units – 6
Batteries – 16
DG set – 1
ACDB – 1

FCOB

BTS, TX

ACDB
Genset 30 KVA
Bat.Cabinet Bat.Cabinet PSU
Confidential
Confidential

12 © 2022 Nokia
Type 4 – DC Sharing
PSU – 0
Battery cabinet – 0
Rectifier units – 0
Batteries – 0
DG set – 0
DCDB – 1

TRS

FCOB
DCDB

Ethio Telecom PSU


Confidential

13 © 2022 Nokia
Summary

Type of solution Hub Grid type Consumption Batteries Rectifier PSU Batt Ext Cab Genset Solar panel Solar Rectifier ACDB DCDB
1.1 no O < 6 hours outage C < 5 Kwatt 4 4 1 0 0 0 0 1 0
1.2 no O < 6 hours outage C > 5 Kwatt 5 4 1 0 0 0 0 1 0
1.3 no O < 8 hours outage C < 5 Kwatt 5 6 1 0 0 0 0 1 0
1.4 no O < 8 hours outage C > 5 Kwatt 7 6 1 1 0 0 0 1 0
2.1 yes O < 6 hours outage C > 5 Kwatt 4 4 1 0 1 0 0 1 0
2.2 yes O < 6 hours outage C > 5 Kwatt 5 4 1 0 1 0 0 1 0
2.3 yes O < 8 hours outage C < 5 Kwatt 5 6 1 0 1 0 0 1 0
2.4 yes O < 8 hours outage C > 5 Kwatt 7 6 1 1 1 0 0 1 0
3.1 no 24 hours outage C < 5 Kwatt 11 6 1 1 1 18 3 1 0
3.2 any 24 hours outage C > 5 Kwatt 16 6 1 2 1 32 4 1 0
3.3 any 24 hours outage C > 5 Kwatt 16 6 1 2 1 0 0 1 0
4 any DC sharing C > 5 Kwatt 0 0 0 0 0 0 0 0 1