Technical Site Survey Report

For Existing Site

(V2014-V1.0)

Site ID JAW-EJV-0035-M-B
Vendor ID ZTE_7214/ZSBY_0664
Site Name KLAMPIS/KEPUTIH
Site Address Jl. Keputih Perintis Kavling No.61, Kel. Keputih,
Kec. Sukolilo, Kab. Surabaya
Subcon Company PT. GCI INDONESIA
Surveyor BAMBANG
Survey Date 7-Jan-15

Company Name Signature Date


Subcon
ZTE
Smartfren

ZTE CORPORATION
Site Survey Report (LTE Site)

1. Current Information
1.1 Site information
Survey
Survey Contents
Items
Site ID: ZTE_7214/ZSBY_0664 Site Name: KLAMPIS/KEPUTIH
Site locatin
Address: Jl. Keputih Perintis Kavling No.61, Kel. Keputih, Kec. Sukolilo, Kab. Surabaya
information
Longitude (E): 112.80116 ° Latitude(S): -7.28882 °
Property type Equipment room location Installation type
High rise building Roof Fan room Shelter
Government premises Platform Pump room Equipment room
Site Public housing estate Water tank Meter room ✘ Cabinet
environment
checking ✘ Village type housing Floor no.: CTER
The link Elevator room Other :
Private shopping arcade Need to climb ladder
Other: ✘ Other : Greenfield
Site attach Smart Mobile 8 ✘ Tower Provider: PROTELINDO
Defined by coverage Indoor ✘ Outdoor
Defined by equipment location Indoor ✘ Outdoor
Site type: Rooftop ✘ Greenfield BSC&RNC&CN
Site type Tower type: Angular ✘ Tubular Mini Pole Others:
Tower/Pole Height (mAGL) 43 M Building Height: (mandatory when using rooftop site)
Wiring way of cable: Not Applicable ✘ Applicable, Way of Installation :
Existing anti-static floor Available ✘ Not Available
Height of anti-static floor _____ cm Anti Static Floor Connected to _______________
Access Restriction Yes ✘ No Specific Reason: Only name in permit can access
Twenty-four hours ✘ Yes No Specific time:
Prior appointment for access ( person to be informed before site access )
✘ Yes No
Contact: Protelindo Helpdesk team as permission letter
Site access Phone: 0800-1-009900
information Fax: Day before :
Need Access Key ✘ Yes No
Need Landlord Key Yes ✘ No
Site access key
Need Other Access Key Yes ✘ No
Please specific:
Equipment delivery method Lift Stairs ✘ Other : Direct

Remarks

All information contained here in the document is confidential! Page 2


Site Survey Report (LTE Site)

1.2 Existing Equipment information


Existing
equipment ✘ CDMA800 ✘ CDMA1900
configuratio System CDMA800 CDMA 1900 Rectifier Rack 19' Others: BS8900
n Rack Qty 1 1
information
✘ AC ✘ DC
Voltage: 220 V Voltage: 53.5 VDC
Electricity PLN 6.6 KVA Current Load 7.8 A
Main Braeker at KWH 3 x 10 A Max Rectifer Module : 4

✘ Three phases Single phase Rectifer Module Equipped: 3


Current Load Phasa R : 0.20 A Each Rectifer Module Capacity: 50/50/50 A
Phasa S : 1.46 A Max Battery Bank Qty : 8 Unit
Phasa T : 1.38 A Battery Bank Equipped Qty : 8 Unit
Power Rectifier MCB capacity at ACPDB : 1, 3p x 16A Each Battery Capacity : 150 AH
supply Spare MCB at ACPDB : 1, 3p x 16A LLVD1 MCB spare (qty&cap) : 1p,1 x 16A
3 ,1p x 4A
2, 1p x 10A LLVD2 MCB spare (qty&cap) : 1p,2 x 100 A

Air conditioner : qty……x……pk : condition ……..


qty……x……pk : condition ……..
qty……x……pk : condition ……..
DC Fan : qty……x……set : condition ……..

Type: FT12-150 (12V,150AH) Brand: Leocih


Battery Visual Condition Check (No Leakage, No Corrosion, No Crack, No Swollen, etc.)
Battery Group Block -1 Block -2 Block -3 Block -4
Bank -1 ok ok ok ok
Bank -2 ok ok ok ok
Bank -3
Battery Bank -4
Battery Voltage Measurement :
Battery Group Block -1 Block -2 Block -3 Block -4
Bank -1 - - - -
Bank -2 - - - -
Bank -3
Bank -4
Grounding bar Qty (Outdoor): 4 Spare GND port Qty (Outdoor): 12
Grounding Grounding bar Qty (Indoor): Spare GND port Qty (Indoor):
Grounding Resistance Measurement : 0.34 (Ohm) Grounding Bar Material: Aluminum Cuprum (indoor&outdoor)

Feeder Total Qty: Spare Qty: -
outlet(FEP) Notes:
Equipment type MW Optical transceiver HDSL Directly connect to 2M wire

Transmission medium MW Optical fiber HDSL cable 2M wire FE/RJ45

Total E1 Qty: Available used
Transmission cable type E1 T1 75 Ω 120 Ω Fiber Others: IP

ODF type: FC SC DDF type: LSA

Tower/Pole No. Diameter antenna Height Ant. Type Pole number Azimuth
Transmissio 1 0.3 37 WTC03-7214DAR Leg A 30
n 2
3
4
IDU Brand Capacity FE Site ID
1 ZTE 50 SBY_01N033 283.46
2
3
4
Existing Length Pole GPS: 30 cm
GPS Length Of GPS Cable to BTS: 18 m
System GPS Antenna Height: 8 mAGL
- Grounding bar 1 outdoor Spare = 8 port
- Grounding bar 2 outdoor Spare = 12 port
Remarks - Grounding bar 3 outdoor Spare = 11 port
- Grounding bar 4 outdoor Spare = 12 port
- Battery not yet finish installed on progress installed

All information contained here in the document is confidential! Page 3


Site Survey Report (LTE Site)

1.3 Existing Feeder & Antenna and Civil Work Information


System Type Main feeder type
CDMA800 1/2” feeder 7/8” feeder 5/4” feeder
Feeder ✘
CDMA1900 1/2” feeder 7/8” feeder 5/4” feeder

Other 1/2” feeder 7/8” feeder 5/4” feeder
System Type 1/2 Jumper length(m) 1/2 Jumper Qty Connector type
Indoor CDMA800
Jumper CDMA1900
Other

Antenna type CDMA800 CDMA1900 Other


✘ ✘ Ant. Height
Ant. Azimut Downtil Jumper Feeder
Model (Building+Pole/ Remark
No. h (º) t (º) length(m) length(m)
Tower) (m)
1 MB2F/3F-65-17/18DE10/8 60 0 37 3 50 DUAL BAND ANTENNA
2 MB2F/3F-65-17/18DE10/8 190 0 37 3 50 DUAL BAND ANTENNA
3 MB2F/3F-65-17/18DE10/8 300 0 37 3 50 DUAL BAND ANTENNA
4
Antenna type CDMA800 CDMA1900 Other
Ant. Height
Ant. Azimut Downtil Jumper Feeder
Model (Building+Pole/ Remark
No. h (º) t (º) length(m) length(m)
Outdoor Tower) (m)
Antenna 1
and Cable 2
3
4
Antenna type CDMA800 CDMA1900 Other
Ant. Height
Ant. Azimut Downtil Jumper Feeder
Model (Building+Pole/ Remark
No. h (º) t (º) length(m) length(m)
Tower) (m)
N/A N/A
N/A N/A
N/A N/A
N/A N/A

Remarks

Pole No. Total length(m) Spare length(m) Antenna No.


1
2
3
4
Pole
5

Note: Spare length = Usable length minus existing antenna length.


Space available for new equipment (indoor/outdoor): Yes No
Civil work ✘
Type of existing foundation: Concret Steel Base Frame Dimension: (3700x1500)mm
✘ ✘
Overview
Access Road Flat Roof/Ground Equipment Room Outlook Equipment Room Inside
photo of site ✘ ✘ ✘

Radio 0° 30° 60° 90°


✘ ✘ ✘ ✘
environment 120° 150° 180° 210°
✘ ✘ ✘ ✘
photo 240° 270° 300° 330°
✘ ✘ ✘ ✘
Pole/Leg Pole1 Pole2 Pole3 Pole4
✘ ✘ ✘
photo Pole5 Pole6 Pole7 Pole8

Remarks - This site not yet finished Installed CDMA

All information contained here in the document is confidential! Page 4


Site Survey Report (LTE Site)

2. New equipment information


2.1 Summary
M1: TDD only, For New site on 17m pole
M2: TDD only, For New site on tower
M3: FDD only, For New site on tower
M4: TDD+FDD, For New site on tower
M5-1: Co_located with existing BS8900 site,TDD+FDD, Reuse power system.Proposed one intergrated rack(ZXDU48 Outdoor Rack) which house the
BBU and IPRAN if any.Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.

M5-2: Co_located with existing BS8900 site,TDD+FDD, New power system.Proposed BC8910A+PC8910A which house the BBU and IPRAN if any.Proposed
3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.
M6-1: Co_located with existing BS8800 site,TDD+FDD, Reuse power system. Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE.
TDD&FDD share dual-band 6 ports antennas. For BBU installation,it depends on existing situation, it could be installed in existing 19"rack if
it's available, or it could be installed in new BC8181A BOX on wall or new 19" rack if space available.

M6-2: Co_located with existing BS8800 site,TDD+FDD, New power system. Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE.
TDD&FDD share dual-band 6 ports antennas. For BBU installation,it depends on existing situation, it could be installed in existing 19"rack if
it's available, or it could be installed in new BC8181A BOX on wall or new 19" rack if space available.

M7: Co_located with existing BS8906E site,TDD+FDD, New power system. Proposed one power rack(ZXDU48 H002) which could house the BBU and
IPRAN if any.Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.

M8-1: Co_located with existing CBTS12 Indoor site,TDD+FDD, Reuse power system.Proposed one 19" rack which house the BBU and IPRAN if
any.Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.
M8-2: Co_located with existing CBTS12 Indoor site,TDD+FDD, New power system.Proposed one 19" rack which house the BBU and IPRAN if
any.Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.
M9: Co_located with existing CBTS12 Outdoor site,TDD+FDD, Reuse power system.Proposed one intergrated rack(ZXDU48 Outdoor Rack) which
house the BBU and IPRAN if any.Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.

M10-1: Co_located with existing SAMSUNG Indoor site, TDD+FDD, Reuse power system.Proposed one 19" rack which house the BBU and IPRAN if
any.Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.

M10-2: Co_located with existing SAMSUNG Indoor site, TDD+FDD, New power system.Proposed one 19" rack which house the BBU and IPRAN if
any.Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.

M11-1: Co_located with existing SAMSUNG Outdoor site,TDD+FDD, Reuse power system.Proposed one intergrated rack(ZXDU48 Outdoor Rack) which
house the BBU and IPRAN if any.Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.

Site Model M11-2: Co_located with existing SAMSUNG Outdoor site,TDD+FDD, New power system.Proposed BC8910A+PC8910A which house the BBU and IPRAN if
summary any.Proposed 3*RRU(R8964)for TDD LTE,proposed 3*RRU(R8862A) for FDD LTE. TDD&FDD share dual-band 6 ports antennas.
M12-1: Co_located with existing BS8900 site,FDD only, Reuse power system.Proposed one intergrated rack(ZXDU48 Outdoor Rack) which house the
BBU and IPRAN if any.Proposed 3*RRU(R8862A) for FDD LTE. FDD use single-band 4 ports antennas.
M12-2: Co_located with existing BS8900 site,FDD only, New power system.Proposed BC8910A+PC8910A which house the BBU and IPRAN if
any.Proposed 3*RRU(R8862A) for FDD LTE. FDD use single-band 4 ports antennas.
M13-1: Co_located with existing BS8800 site,FDD only, Reuse power system.Proposed 3*RRU(R8862A) for FDD LTE. FDD use singal-band 4 ports
antennas. For BBU installation,it depends on existing situation, it could be installed in existing 19"rack if it's available, or it could be
installed in new BC8181A BOX on wall or new 19" rack if space available.

M13-2: Co_located with existing BS8800 site,FDD only, New power system.Proposed 3*RRU(R8862A) for FDD LTE. FDD use singal-band 4 ports
antennas. For BBU installation,it depends on existing situation, it could be installed in existing 19"rack if it's available, or it could be
installed in new BC8181A BOX on wall or new 19" rack if space available.

M14: Co_located with existing BS8906E site,FDD only, New power system.Proposed one power rack(ZXDU48 H002) which could house the BBU and
IPRAN if any.Proposed 3*RRU(R8862A) for FDD LTE. FDD use single-band 4 ports antennas.
M15-1: Co_located with existing CBTS12 Indoor site,FDD only, Reuse power system.Proposed one 19" rack which house the BBU and IPRAN if
any.Proposed 3*RRU(R8862A) for FDD LTE. FDD use single-band 4 ports antennas.

M15-2: Co_located with existing CBTS12 Indoor site,FDD only, New power system.Proposed one 19" rack which house the BBU and IPRAN if
any.Proposed 3*RRU(R8862A) for FDD LTE. FDD use single-band 4 ports antennas.

M16: Co_located with existing CBTS12 Outdoor site,FDD only, Reuse power system. Proposed one intergrated rack(ZXDU48 Outdoor Rack) which
house the BBU and IPRAN if any.Proposed 3*RRU(R8862A) for FDD LTE. FDD use single-band 4 ports antennas.

M17-1: Co_located with existing SAMSUNG Indoor site,FDD only, Reuse power system. Proposed one 19" rack which house the BBU and IPRAN if
any.Proposed 3*RRU(R8862A) for FDD LTE. FDD use single-band 4 ports antennas.

M17-2: Co_located with existing SAMSUNG Indoor site,FDD only, New power system. Proposed one 19" rack which house the BBU and IPRAN if
any.Proposed 3*RRU(R8862A) for FDD LTE. FDD use single-band 4 ports antennas.

M18-1: Co_located with existing SAMSUNG Outdoor site,FDD only, Reuse power system. Proposed one intergrated rack(ZXDU48 Outdoor Rack)
which house the BBU and IPRAN if any.Proposed 3*RRU(R8862A) for FDD LTE. FDD use single-band 4 ports antennas.
M18-2: Co_located with existing SAMSUNG Outdoor site,FDD only, New power system. Proposed BC8910A+PC8910A which house the BBU and IPRAN if
any.Proposed 3*RRU(R8862A) for FDD LTE.FDD use single-band 4 ports antennas.

M19: For existing indoor DAS site,TDD only, New power system.Proposed one 19" rack which house the BBU and IPRAN if any.Proposed
2*RRU(R8964) for TDD LTE. Reuse existing antenna & distribution system, add combiner only.
M20: For shooting site solution,FDD only,Reuse power system.Proposed one intergrated rack(ZXDU48 Outdoor Rack) which house the BBU and
IPRAN if any.Proposed 1*RRU(R8862A) for FDD LTE. FDD use single-band 2 ports antennas.
M21:For Pico Site

2.2 Preliminary Solution


BS8900/8800/8906E Qty: 1 Power supply AC ✘ DC
Installation
Enough space for BBU/DWDM Indoor installation of 19" cabinet
Swap samsung BTS Swap CBTS Swap SDR
Site New ZXDU48 Cabinet Qty: 1 Power supply ✘ AC DC Dimension:
configuratio
n New RRU/RSU:
information Installation
(preliminary Cabinet for RSU, ( Indoor Outdoor )
stage)
Steel frame for RRU, ( Indoor Outdoor )
Pole-mount for RRU, ( Indoor Outdoor )
✘ Tower-mount for RRU, ( Indoor ✘ Outdoor ) ✘ Others: Put on behind new antenna
Structural stability Yes ✘ Future checking
Indoor Grounding bar Qty: Outdoor Grounding bar Qty: 4

All information contained here in the document is confidential! Page 5


Site Survey Report (LTE Site)

Power type Equipment Qty Installation type Position


Power ✘ DC Rectifier Rack/Cab 1 outdoor
configuratio Rectifier Module 3 outdoor
n
Battery 8 outdoor
information
(preliminary DC distribution box Wall-mount Ground Other Pole-mount
stage) AC Breaker
AC distribution box Wall-mount outdoor
New Battery ✘ Yes No
New Battery Cabinet ✘ Yes No
Battery New Battery Replacement Yes ✘ No
How many bank battery can be inserted to existing battery rack? Full
Is there available space to propose new battery rack? ✘ Yes No

Remarks

ACPDB-BS8800/8900/ZXDU48 AC Length(m): 15 m
BS8800/8900/ GND cable length (m): 10 m
Indoor/Outdoor Cable type Sct1 Sct2 Sct3 Sct4 Sct5 Sct6
DC BBU - RRU power cable Length(m) 2*50 2*50 2*50
Cable BBU - RRU Fiber cable Length(m) 2*50 2*50 2*50
Jumper cable (RRU to Ant.) Length(m) 3*6 3*6 3*6
RRU GND - Grounding Bar cable length(m): 3*5 3*5 3*5
New vertical cable tray required: Yes ✘ No length:
Feeder cable tray
New horizontal cable tray required: Yes ✘ No length:
Length Pole GPS 30cm
Proposed
GPS Length Of GPS Cable to BTS 18 m
System (if GPS Antenna Height 8m
any)
Cable type ✘ Φ9mm 1/2" 7/8"
Delete antenna
Ant. No. Pole Ant. Model Ant. Pole Ant. Model Ant. Pole Ant. Model
No. No. No. No. No.

1
2
3
4
Antenna
suggestion Add antenna
(preliminary New Pole Ant. Model Pole height(m) Ant. height (m) Azimuth (°) Downtilt (°) Remark
stage) Ant. No.

N1 1 CVV65CSX-M 37 0 9 Leg A
N2 3 CVV65CSX-M 37 120 5 Leg B
N3 4 CVV65CSX-M 37 240 5 Leg C
N/A N/A
N/A N/A
N/A N/A

Remarks - Plan antenna height at 33 M , Proposed at 37 Magl

Equipment Type: ✘ MW Optical Transceiver HDSL Direct connect to 2M wire


Transmission Medium: MW Optical Fiber HDSL 2M wire ✘ FE/RJ45
Transmission Cable Type: E1 T1 75ohm 120ohm ✘ Others: IP
Transmissi ODF Type: FC SC DDF Type: LSA
on Tower/Pole
Diameter Antenna Height Ant. Type Pole Number Azimuth
No.
1
2
3

IDU Brand Capacity FE Site ID


1
2
3
Propose new foundation outdoor: Yes ✘ No Dimension:
Propose new sun shield: Yes ✘ No
Propose extend shelter Yes ✘ No
Civil work
Propose new air conditioner Yes ✘ No qty : …….x…….pk
Propose up grade electricity :………….VA, from……......VA to : …………..VA
Comments:
Equipment No Equipment name Qty Dimension
1
Obsolete 2
equipment
list 3
4
5

Remarks

All information contained here in the document is confidential! Page 6


Site Survey Report (LTE Site)

Site Photo Check List


Photo Number of
SN Detail
Taken Photos
A Site Overview Photo
1 Access Road Yes 1
2 Site Front View Yes 1
3 Existing Site Gate Yes 1
4 Existing Surrounding View Yes 4
5 Existing Tower Yes 2
B Existing Equipment Information
1 Existing Antenna (RF&MW) Yes 1
2 Existing main MCB at KWH meter Yes 1
3 Existing ACPDB Yes 1
4 Existing AC Current Load Yes 3
5 Existing air conditioner (indoor site) No 0
6 Existing DC Fan (indoor site) No 0
7 Existing Rectifier Cabinet Yes 1
8 Existing DC Current Load Yes 1
9 Existing DCPDB (internal and external rectifier) Yes 1
10 Existing Battery System Yes 1
11 Existing Transmission Equipment Yes 1
12 Existing DDF No 0
13 Existing Cable Ladder Yes 2
14 Existing Indoor Grounding Bar No 0
15 Existing Outdoor Grounding Bar Yes 4
16 Existing Inlet No 0
17 Existing Shelter & Foundation ,Stairs etc. No 0
18 Existing Foundation Outdoor Yes 1
B Panoramic View
1 Panoramic View 0° Yes 1
2 Panoramic View 30° Yes 1
3 Panoramic View 60° Yes 1
4 Panoramic View 90° Yes 1
5 Panoramic View 120° Yes 1
6 Panoramic View 150° Yes 1
7 Panoramic View 180° Yes 1
8 Panoramic View 210° Yes 1
9 Panoramic View 240° Yes 1
10 Panoramic View 270° Yes 1
11 Panoramic View 300° Yes 1
12 Panoramic View 330° Yes 1
C New Equipment Proposal
1 Proposed New Cabinet for LTE Yes 1
2 Proposed New Vertical Cable Ladder For Cabinet No 0
3 Proposed Cable Routing for LTE Yes 1
4 Proposed New Inlet for LTE No 0
5 Proposed Reuse existing IGB for LTE (Indoor) No 0
6 Proposed Reuse Existing MGB on Tower for LTE (Outdoor) Yes 1
7 Proposed new MGB on Tower for LTE No 0
8 Proposed AC Power System No 0
9 Proposed New RF Antenna & RRU Yes 1
10 Proposed New GPS Antenna for LTE Yes 1
11 Proposed NEW Cabinet No 0
12 Proposed Rectifier System Yes 1
13 Proposed New battery Yes 1
14 Proposed New Cable Ladder No 0
15 Proposed MW Antenna and direction to FE No 0
16 Proposed IDU No 0
17 Proposed ODU No 0
18 Proposed Transport ODF/OTB Equipment (Switch, Router, etc) No 0
19 Proposed DCPDB for ODF/OTB No 0
20 Proposed Cable Route for ODF/OTB No 0
21 Proposed new rack for ODF/OTB No 0
22 Proposed Jumper Cable from Antenna to RRU Yes 1
23 Proposed new Outdoor Cabinet No 0
24 Others Specify No 0
Comment:

All information contained here in the document is confidential! Page 7


Site Survey Report (LTE Site)

3. Site Photo
3.1 Site Overview Photo

Access Road Site Front View

Existing Site Gate Existing Surrounding View

Existing Tower Existing Antenna (RF&MW)

Use MCB at ACPBD 3


x 16 A

Existing main MCB at KWH Meter Existing ACPDB

All information contained here in the document is confidential! Page 8


Site Survey Report (LTE Site)

Existing AC Current Load Existing Air Conditioner (indoor site)

Existing DC Fan (indoor site) Existing Rectifier Cabinet

DC CURENT LOAD
53.8 V 7.8 A

Existing DC Current Load Existing DCPDB internal (at rectifier rack)

Battery not yet


installed all (site on
progress installed)

Existing DCPDB external (at another rectifier rack) Existing Battery System

All information contained here in the document is confidential! Page 9


Site Survey Report (LTE Site)

Existing Transmission Equipment Existing DDF

Existing Cable Ladder Existing Indoor Grounding Bar

Existing Outdoor Grounding Bar Existing Inlet

Existing Shelter & Foundation ,Stairs etc. Existing Foundation Outdoor

All information contained here in the document is confidential! Page 10


Site Survey Report (LTE Site)

3.2 Environment Photo (Panoramic View)

EN 0° EN 30°

EN 60° EN 90°

EN 120° EN 150°

EN 180° EN 210°

All information contained here in the document is confidential! Page 11


Site Survey Report (LTE Site)

EN 240° EN 270°

EN 300° EN 330°

All information contained here in the document is confidential! Page 12


Site Survey Report (LTE Site)

3.3 New Equipment Proposal

Proposed new
Cabinet for LTE

Proposed New Cabinet for LTE Proposed New Vertical Cable Ladder For Cabinet

View Cable route for


LTE

Proposed Cable Routing for LTE Proposed New Inlet for LTE

Proposed Reuse existing IGB for LTE (Indoor) Proposed Reuse Existing MGB on Tower for LTE
(Outdoor)

Proposed new MGB on Tower for LTE Proposed AC Power System

All information contained here in the document is confidential! Page 13


Site Survey Report (LTE Site)

Proposed New
Antenna LTE

Proposed New RF Antenna & RRU Proposed New GPS Antenna for LTE

Proposed new
Power System For
LTE

Proposed NEW Cabinet Proposed Rectifier System

Proposed new
Battery 8 block

Proposed New battery Proposed New Cable Ladder

Proposed MW Antenna and direction to FE Proposed IDU

All information contained here in the document is confidential! Page 14


Site Survey Report (LTE Site)

Proposed ODU Proposed Transport ODF/OTB Equipment (Switch, Router,


etc)

Proposed DCPDB for ODF/OTB Proposed Cable Route for ODF/OTB

View Cable route


Antenna RRU

Proposed new rack for ODF/OTB Proposed Jumper Cable from Antenna to RRU

Proposed new Outdoor Cabinet Others Specify

All information contained here in the document is confidential! Page 15


4. Drawing
4.1 Site Map

Note :
1. Address : Jl. Keputih Perintis Kavling No.61, Kel. Keputih, Kec. Sukolilo,
Kab. Surabaya
2. Coordinate : Longitude = E 112,80116
Latitude = S-7.28882

Page 15
4.2 Site Layout

19200
1500 2900 2100 3700 9000
1800

1800

3000
865

1600

1150
9465
5400

3464
AC 3
AC 1 AC 2

1701
1400

1500 2900 1950 4000 8850


KELAMPIS
Layout Scale : nts

Page 16
4.3 Equipment Room Layout and Cable Routing

Page 17
4.4 Antenna Placement

EXISTING SMARTFREN
EXISTING SMARTFREN
AZ : 30 °
SECTORAL ANTENNA
ON ± 37.00 M.A.G.L ON ± 37.00 M.A.G.L

EXISTING MW Ø0.3
ON ± 37.00 M.A.G.L

EXISTING SMARTFREN
MB2F/3F-65-17/18DE10/8
SECTORAL 1
DOWNTILT : 0 AZ : 60 °
ON ± 37.00 M.A.G.L

EXISTING SMARTFREN EXISTING SMARTFREN


MB2F/3F-65-17/18DE10/8 MB2F/3F-65-17/18DE10/8
SECTORAL 3 SECTORAL 2
DOWNTILT : 0 AZ : 300 ° DOWNTILT : 0 AZ : 190 °
ON ± 37.00 M.A.G.L ON ± 37.00 M.A.G.L
43000

PROPOSED ANTENNA
CVV65CSX-M
SECTORAL 1
DOWNTILT : 3 AZ : 0 °
ON ± 37.00 M.A.G.L

PROPOSED ANTENNA PROPOSED ANTENNA


CVV65CSX-M CVV65CSX-M
SECTORAL 3 SECTORAL 2
DOWNTILT : 4 AZ : 240 ° DOWNTILT : 4 AZ : 120 °
ON ± 37.00 M.A.G.L ON ± 37.00 M.A.G.L

EXISTING GPS PROOSED GPS


ON ± 8.00 M.A.G.L ON ± 8.00 M.A.G.L

Page 18

Tower SST 43 m
EXISTING GPS PROOSED GPS
ON ± 8.00 M.A.G.L ON ± 8.00 M.A.G.L

Tower SST 43 m

Page 19