= a] lau Ghantoot Gulf Contracting | Naga Architects, Designers & DAMAC Properties Planners. CONTRACT ‘dent SUBMITTAL DESCRIPTION: _ | Golf Residential Community-DAMAC REF. No | TD0c-014 (01) ft i PROJECT PROJECT NAME: | Golf Residential Community-DAMAC NUMBER: | 3045 Project Specific Rev. Rev. a v Generic MS: Number.| °° | Beto: | 15012014 METHOD STATEMENT TITLE: METHOD STATEMENT FOR CONSTRUCTION OF BLOCKWORKS AT SUBSTRUCTURE Rev. Date nee No. of Pages | Description Prepared By: Approved By Issued tothe 1101/2014 | 01 1aPages | Engineer for | AKarim Ahmed | cM | Ammar PM approval Page 1 of7 = ~ lau Ghantoot Gulf Contracting | Naga Architects, Designers & DAMAC Properties Planners CONTENTS 1.0 SCOPE OF WORKS 2.0 CONSTRUCTION PROGRAMME 3.0 CONTRACT DOCUMENT REFERENCE 4.0 RESPONSIBILITIES 5.0 EQUIPMENT 6.0 PROCEDURE 7.0 QA/QC 8.0 SAFETY 9.0 ATTACHEMENTS Page 2 of7 > | = mo] Ghantoot Guif Contracting | Naga Architects, Designers & DAMAC Properties Planners 1.0 SCOPE OF WORKS This Method Statement covers the procedure for the Construction of Solid Concrete Block work at Substructure for Golf Residence community Project. 2.0 CONSTRUCTION PROGRAMME As per latest approved construction programme. 3.0 CONTRACT DOCUMENT REFERENCE Contract General Specifications (Volume 1, Section: 042200 —concrete units -Block Works). Approved Project Quality Plan Approved HSEM Plan. Approved contract Drawing. Approved Shop-drawing. 4.0 RESPONSIBLITIES 4.1 CONSTRUCTION MANAGER/PROJECT ENGINEERS & ENGINEERS 4.1.1. Ensuring that the Surveyors and Foremen are aware of latest issue of “For Construction” shop drawings. 4.41.2. Ensuring that the works are carried out to the levels and layout made by the Surveyor 4.1.3 Ensuring that the works are carried out in accordance with the approved method statement. Page 3 0f7 5S & moe Ghantoot Gulf Contracting | Naga Architects, Designers & DAMAC Properties Planners 4.1.4 If the approval is given at night or in dark interiors, adequate lighting shall be placed at the work spot. 4.2 LAND SURVEYORS 4.21 The Surveyors will be responsible for establishing the Control Points, Bench Marks, levels for the Block work. 4.3. FOREMAN AND OTHER TRADE 4.3.1 Different discipline Foremen and other trade will follow this method statement as directed by Construction Manager/Project Engineer and Engineers. 4.4 QC ENGINEERS 4.4.1 QC Engineers will document all inspections and check lists, and inspection request will be raised as per the Inspection and Test Plan specific to this activity and shall be submitted separately for review and approval of the Engineer. 4.4.2. Alltests required shall be carried out in accordance with Specifications and Applicable BS codes by an approved Independent Laboratory. 4.4.3. Test reports shall be forwarded to the Engineer once received from the Independent Laboratory 5.0 EQUIPMENT 5.1 Plumb Bob/Survey strings, Containers for mortar, mixing tools, Block cutting machine _/ Grinders, Survey -Total station, mobile lighting tower (in case of night operations) and other miscellaneous items. Page 4 of 7 P / z | sia | i Ghantoot Gulf Contracting | Naga Architects, Designers & DAMAC Properties Planners: 6.0 PROCEDURE 61 6.2 63 64 65 66 67 68 69 6.10 6.14 6.12 6.13 6.14 6.15 Only approved shop drawing (latest revisions) will be issued to site team. The work should not proceed until area is clean, and free from debris. R.C. walls/columns in contact with block work shall be properly cleaned. Approved block accessories with all relevant tools shall be available near masons. (Shooting machine, nails, grinders, cutting discs etc). Specified trained and skilled labors shall be assigned to use the mechanical tools. All blocks and block bed shall be adequately wetted. Surveyor to mark the layout of block walls (Internal and External) according to the approved shop drawings. Inspection request to be raised to the Engineer to check/ Approve the lay out. Upon approval of layout, work to proceed for the maximum height of not more than five courses of blocks in any one day within any section of walling. Solid Concrete blocks should be cut if necessary with mechanical cutting disc on site, Joints to be aligned horizontally, and staggered, aligned vertically. Strictly follow the mortar manufacturer instructions related to mixing ratios, mixing procedure and time of mixing. The approved block accessories must be fixed and placed as the approved sample and recommended by manufacturer. Block walls shall be reinforced horizontally with expanded stainless stee! mesh joint reinforcement embedded in the horizontal mortar joints not closer than 20mm from the external face of the wall and except at movement joints, shall be continuous and lapped at least 75mm at all passings. Expanded steel mesh horizontal reinforcement shall be provided every second course or as shown in the approved shop drawings. Wall ties shall be built in the mortar beds as the work proceeds and shall be spaced at a maximum of 800 mm horizontally and 400 mm vertically and shall be staggered Page 5of7 = [as ACT Ghantoot Gulf Contracting | Naga Architects, De: Planners ers & DAMAC Properties 6.16 All joints shall be of consistent thickness (average 10mm), all horizontal joints shall be properly leveled and vertical joints shall be properly lined and quoins and other angles plumbed as the work proceeds. 6.17 Continuous curing for the executed masonry walls shall be ensured as per the mortar manufacturer's recommendation. 6.18 Producti \n of mortar on site ‘Approved design mix shall be used. * Cube test for comprehensive strength of mortar will arrange. © Dry mixed from Ready Mix Plant will be used and mortar shall be mechanical mixers. ‘+ Mixed mortars shall be stored above polythene sheets and transported to the required place with hand tools. The mixed mortar shall be used within 30 minutes after adding water. No further water should be added to the mix. + Hard and set materials should not be re-mixed. id with 6.19 Waterproofing: Both faces of the Solid block works below ground level shall be treated with two coats of rubberised bitumen paint. 6 Qalac All inspection requests shall be submitted to the Engineer prior to application of the material. The following points shall be ensured. * Appropriate approved materials are used. ‘+ Appropriate equipment is used. * Skilled labourers are used for the application of material. Page 6 of7 = 5 [au Ghantoot Gulf Contracting | Naga Architects, Designers & Planners DAMAC Properties 7 SAFETY 7.1. Proper PPE shall be used. Dust masks and gloves shall be wom while doing chipping and cleaning. 7.2 Works shall be carried out in strict compliance with the approved HSEM Plan and all prerequisite will be met as required and identified in the approved HSEM Plan. 8 ATTACHMENTS Risk Assessment for Block work laying - G6C/RA/GCV/19. ITP Cover. ITP /03. MEP Clearance checklist. Block-work checklist. Page 7of7 Golf Community Villa | Doc Number HSE PROCEDURE Revision 0 RISK ASSESSMENT AND CONTROL MEASURES: Project Number Prgjeet ay Taseaament By Reviewed By asesemeni NO] Gav BLOCK WORK Wir Rajesh ie Ray GSGRAGVEOTE | oteral Haaard / Conditon t be Consdared Deep ‘Wark on Over Water [| Fallfom Hoight Fre Risk High Winds ‘Young Persons Gindlng Confined Fale on Level Woise Dust |] Adverse Weather |_| Expectant round ali mat Plant Machinery |_| Working Platfomms 7 |_| Sips/ Tipping Fumes Emironmentad Gihor Workers iting Oparatens | | Manuar Handing Fuel Sorage "Tate ‘raining Required | | General Publ ‘Buried ‘COSHH SiorageTLay Down | | Ground Health Rai cUL ‘Overhead Area Conditions ‘Survellance. NE HAZARD IDENTIFIED AT RISK inal | CONT Rasiual Rak DESCRIPTION (People | Property ete) ROL tys [Re tysyR 7] Unaulatie parsonnet | —Parsonnal mvelved, helpar waviman in| 5 [5 | 25 SSE PHC [T [2 ]2 | {Block cutting proximit 2 | Amputation Personnel involved in cling S]a [a SSEPMGM [TE ]z Block eutng ) 3] Electric shock Personnel invoned atwarkpiace, [5 |S | 25 SEISEPH [72 ]2 (Block cutting supervisor 2 | ou F [inhalation of biock dust | Personnelat workplace supervisor [5 [4 [20] &|SsePmcm [1 [2]? (Block cuting ) 2 | Sips Tips Block Porsonnelimaved moving around, [84 [20] & [SSEPM [1 ]2|2 sina) jpenvisor inspector, g © | Fall rom height Personnel nvoWved, working /maving [5 [5 [25] g [SSEPMOM [T [2] 7 Fall of biocks/To0ls7 Personnel invoWed, working moving —]5 {5 [25] * | SSEPMOM/1 2]? materials Underneath & property 3 Taskof co-ordination Parzonnel involved in promi, | 3 [| 25 SPM [7722 Undecneath the activity [Crush janes while Personnalinvoved (Mason) Ea) SPAT Tze 70 | Eve ifures Parsonnalinvawed (Mason & Halper) 5 [4 | 20 SPM T [2 [2 Risk Ra Tketiood Risking Rating “The above risk assessment 5 43) 2 04 Sway has been briefed an fully Understod 52 20 16 10 5 5 Tajorijry leading Fatally Name | Design] Sig 4|2 1 12 8 4 n [re 3/1 12 9 6 3 (2/0 8 6 4 2] [4 TTA Teading to Hosptaization 24/5 4 3 2 4 ‘ajar jury Paluion Damage 2 2 Minor Polluton/ DamagelLoss 8 7 Tnry Lew Damage Loss 9 or more = Unacceptable Risk Uikathood Risk Rating = Sx L=R 5 Eaemely igh probabiny 4 igh Ukely Risk Assessment briefed by 3 Tike Name | Rajesh Date [9/1277 2 Possible ‘Signature Seah Time| 7 ever Very Unlikely PI Plann charge PM Project Manager, CM: Constucton Manager, SE: Ske engineer, S: Supervisor, rman, SK: Store keeper porator, BM Banks Page 1of1 Golf Community Vila Doc Number HSE PROCEDURE Revision 0 ‘CONTROL MESURES Project Number HAZARD, 1) Fire accident / Hazard. 2) Skin Allergy. 3) Respiration deficiency. 4) Slips / Trips. 5) Falling of people / material 6) Environment Pollution CONTROL MEASURES a) b) °) a °) fy 2) b) °) a) ») a) b) °) d) Trained and competent personnel should be deployed for such critical activities. ‘Adequate fire fighting equipment should be provided at the work place. Permit system (as per company policy) should be strictly followed by all, whom so ever is dealing with such hot works. Alert / fire fighting team should exist effectively. Adequate safety signage's to be provided to avoid un authorized activities in near proximity PPE should be used by the respective workmen. Adequate safety signages to be provided / displayed. ‘Authorized persons should be allowed to handle the lob. AAI the workmen involved in such activities should be very competent in handling and working procedures, Workmen involved should be given rest period (small duration) at regular intervals. Suitable nose mask should be used by the workmen. Training to the workmen Increasing the frequency of conducting tool box talks as itis very ortical activity. Continuous supervision is must. Suitable PPE should be used by the workmen, Training to the workmen. Adequate space / working space should be provided to the workmen so that to avoid falling of people and material Continuous supervision by a competent person and should ensure that necessary PPE is used by the workmen. ‘Strict implementation of permit system. Spillages of chemicals and misusage should be strictly avoided. Explaining the workmen, the results of environment pollution in regularly conducted tool box talks. Storing of toxic materials in appropriate containers by which we can avoid any soft of toxic gases / fumes emission into the atmosphere. Page Loft eee = = =o =e ren =I Tenant 38 ‘iva awe /avi uns TesuTbug as B BBRIEH woRMASIOD 959 | —____aMNo seoui6u3 DOWD # °5=uEW DONO 299 ‘ano ennewwesesdoy /2902ueN 900 | VOWN "Rive SHBUaD9 mala moinay a | euonde st amenasaday «66a 7 FST a Aq WHRBBID Wea: Bu poooad wuoa ssomM m emey wopuey w ‘Sanaa ING ‘wonssyHeA ors ‘wonedsu ‘unsox Teaaudey ‘adi se800%8 ‘STOSWAS NVTd 1531 GNV NOILOSdSNI JO NOILINII FON NOISINRY aL aaBeuew refed | :Ag GROWN dD 3009 ait | ‘SOM 4034095 ‘DvHIWO AB VAODY | :NOU¥IOT JOD NVid LSS GNV NOILO3dSNI LNAWAAONAMI 8 SISATVNV ‘ONINOLINOW ‘LNSWSaNSVaN BuysesUo9 jin9 yoojueyD =) erm oaea an a hate sng sa 4 ups Se payne 9 yu pe seat se pausep a sad ple pasducn yy weyshs WOU jenoce pe saat amsvo 0 pve ae US WH So UO, ‘su0u248 Ue uo peueEWs usurp sy 0 £600 SEU By) ava oy Foe Sowovown ahaa 200 dosages say worries 989 ns snon03 a Pee eee staan ee | reroiddy ssoumt 3000 vow fo, amouaiy conanay coving sonanoaus | sauna nog (i) S5304IM aN (H) O70 ss108 ‘S36, 7OMINOD i ee som om fun 8 nS morons | awsome | miSESSR, | 2 wow wy mivnennreca FE v om ove rougsaes | onasrowsnsesy 2 mom seo sn nds Yongwon 1 oom yom 10018 eg Perm ¥ tH wom aN YAM ™ no reap yon nus rou aauns wiw lwo = “a9 rong momo aoweiriod spo | 8 | oe | vom || oe namoca ‘phnoraa | cas sma in sonnet 0H iors [va aut FON ROIS dt ebeuen wel01d |» zz 0/4 ‘Suom yo01g -asmonas ans aC sNouv: oer ofA | ron a9 pom xo01a -aumionaas Qns | :SkHON 40 098 ‘DYPIVG AB VAOMY | NOUY90T dod Ter er NVId LS31 GNV NOILOSdSNI wiocios: [10 ji i ‘ie “ney “ON “ny ANSW3AONdMI! ® SISATWNV ‘ONINOLINOW ‘LNAIWSeNSVaW ‘tion 0 Sie a Bupoesjuos 41ND Joojueyo =n! ; om, Ghantoot Gulf Contracting PEGE Tee ‘QUALITY CONTROL. Reta eva ssnia04 5 MEP SERVICES CLEARANCE Tat Project EP Ret Deseristion Date Drawingsispecs ‘ety Leeaion| [7 asc MEP Subcontractor GGG. MEP, CLIENT REPRESENTATIVE PLOMENG ceRvices Jonre oF ptannco coNcRETING/AcTVIY: [rime oF PLANNED CONCRETING/ACTIVITY: Construction Fiald MEP Engineer Soran: TRICE ABOVE ACTIVITIES LLY GCONPLIED AND CAN BE NGREGTED AS PER SOVEDULE COMMENTS REWARRS. TEP SUBCONTRACTOR. TECMEPENGNEER ‘ELIENT REPRESENTATIVE = Document Raernee Ghantoot Gulf Contracting TDoe—014 =, Reino | Rev Dae QUALITY CONTROL oO ssn | BLOCKWORKS INSPECTION CHECKLIST ee server Contra i AKOYA BY DAMAC Location (gridlines): Drawing Reference: Mortar class spec: HECKLS yes | No | NA 1 Set out layout for new wall 2 Cheok if DPC is required 3 Check connection detail to other structure ie. soft board, soffit ete 4 Set out window openings or buil in iterns Ike door frames for plumb and level 5 Check window sils and beam filing (i required). 6 Check iftintels are required 7 Check spec on Brickforce and Block tles 8 Check bonds between blocks and mortar, Do blocks need to be wet? 9 Check alignment & plumbness of wall 10 Check if adsltional reinforcing required e.g. mesh 41 Ensure correct access and installation of working platforms i= 12 Ensure there is no overloading of materials and workers on platforms. 13. Ensure all hand tools are in good working order 14 Ensure the use of appropriate personal protective gear 7 15 __ Manage relevant signatures on safety tems (CHECKED BY CONTRACTOR Name: Siar Date: (Site Engineer) Name: Sign: Date: {QA/QC Engineer) -CEPTEL ER: Random Inspection: Sign:

You might also like