You are on page 1of 2

CT

MEDRAD® Stellant Technical Specifications

Height Width Depth Weight

Dual injector head 15.5 cm (6.1”) 30.7 cm (12.1”) 36.8 cm (14.5”) 8.1 kg (17.9 lb) (without syringe)

Base unit 28.6 cm (11.25”) 27.9 cm (11.0”) 22.9 cm (9.0”) 6.2 kg (13.6 lb)

Workstation 3.0 27.3 cm (10.8”) 38.4 cm (15.1”) 20.2 cm (7.9”) 7.2 kg (15.8 lb)

Ordering Information Injection Specifications Software and Interface Miscellaneous


Systems listed include all Flow rate Specifications Specifications
standard cabling (range and increments): P3T Personalized Protocols: Electrical requirements (VAC/Hz):
0.1 – 10 mL/sec Catalog number: STI2-P3T Workstation 3:
MEDRAD® Stellant D
in 0.1 mL increments 100 – 240 VAC, 50/60 Hz, 1.3 A
Injection System //Automated Documentation: Base Module:
with pedestal head mount Volume Catalog number: 100-240 VAC, 50-60 Hz, 300 VA
(order number: SCT 310) (range and increments): CWKS STARTER PKG
Syringe heat maintainer:
MEDRAD® Stellant D CT 1 mL to syringe capacity in
RIS interface: 35 degrees C +/-5 degrees,
Injection System 1 mL increments
Catalog number: MIS PCS 301 95 degrees F +/-9 degrees
with workstation and Programmable pressure Head mounting options:
Dictation interface:
counterpoise system head limit (psi/kPa): Overhead counterpoise system
Catalog number: MIS PCS 300
mount (order number: SCT 322) 200 mL syringe: or floor pedestal (floor pedestal
325 psi, 2241 kPa Scanner interface: includes an integral IV pole)
Catalog number: DualFlow:
Pause:
ISI700/800/900, ISI2 Simultaneous injection of
1 – 900 seconds (15 minutes) contrast and saline is included and
in 1 second increments integrated in the workstation
Hold: VirtualCare®**:
Maximum hold time is 20 minutes Remote service on the injector and
software to ensure faster uptime
Syringes (volume capacity):
200 mL sterile disposable syringe
**Not available in all countries
Maximum number of phases:
6
CT

Bayer reserves the right to modify the specifications and features described herein or to discontinue any product or service identified
in this publication at any time without prior notice or obligation. Please contact your authorized Bayer representative for the most
current information.

The patient data that appear in this document are fictitious protected health information (PHI) and/or actual PHI from which all
personally identifiable information (PII) has been removed or otherwise anonymized. No personally identifiable information is shown.

Bayer, the Bayer Cross, MEDRAD Stellant, Certegra, VirtualCare, Radimetrics, and P3T are trademarks owned by and/or registered to
Bayer in the US and/or other countries. Other trademarks and company names mentioned herein are properties of their respective
owners and are used herein solely for informational purposes. No relationship or endorsement should be inferred or implied.

© 2023 Bayer. This material may not be reproduced, displayed, modified, or distributed without the express prior written consent of
Bayer.
PP-M-STE-ALL-0041-1  January 2023

Bayer AG Manufacturer Authorized European


13353 Berlin, Germany Bayer Medical Care Inc. Representative
1 Bayer Drive Bayer Medical Care B.V.
More information on Indianola, PA 15051-0780 Avenue Céramique 27
radiology.bayer.com U.S.A. 6221 KV Maastricht
Phone: +1-412-767-2400 The Netherlands
+1-800-633-7231 Phone: +31 (0) 43-3585602 
2797 Fax: +1-412-767-4120 Fax: +31 (0) 43-3656598

You might also like