You are on page 1of 5

design

PUMP AND LINE SIZE CALCULATION


typical velocit 2 m/s
Fluid Water area of pipe 0.001394523 m2
temperature 35 C diameter 0.042148106 m
density 986 kg/m3 42.14810596 mm
viscosity 0.8 Cp economic pipe diameter
normal flow rate 2.75 Kg/s d,optimum 37.23639688 mm
design max. Flow rate 3.96 Kg/s
volumetric flow rate 0.002789047 m3/s
equipment pressure 1 bar
cross sectional area of pipe 1962.5
0.0019625
fluid velocity 1.421170269
SUCTION CALCULATION f 0.005454534
LINE SIZE 50 MM
from friction chart
normal maximum f 566.985986
VELOCITY 1.421170269 1.2528 m/s f 0.566985986
FRICTION LOSS 0.566985986 0.81645982 kpa/m
LINE LENGTH 6.00488408 8.647033075 m
LINE LOSS 3.404685121 4.902746574 kpa
ENTRANCE LOSS 1.433843125 2.0647341 kpa
STRAINER 40 40 Kpa
SUBTOTAL1 4.838528246 6.967480674 kpa
static head 1.2 1.2 m
density*g*z1 11.607192 11.832 kpa
equipment pressure 100 100 kpa
sub total 2 111.607192 111.832 kpa
SUCTION PRESSURE 106.7686638 104.8645193 Kpa
vapour pressure 40 40
NPSH 6.902823396 6.705964991 m

cross sectional area of pipe


DISCHARGE CALCULATION
LINE SIZE 40 MM velocity
VELOCITY 0.056803394 0.081796888 m/s
FRICTION LOSS 0.000540847 0.00077882 kpa
LINE LENGTH 14.24 20.5056 m
LINE LOSS 0.007701661 0.015970164 kpa
control valve 50 72 kpa
Dynamic loss 50.00770166 72.01597016 kpa
static head 3.2 3.2 m
Equip. pr. 100 100 kpa
density*g*z2 30.952512 30.952512 kpa
subtotal 130.952512 130.952512 kpa
discharge pressure 180.9602137 202.9684822 kpa
suction pressure 137.344 137.857889 Kpa
Diff pressure 43.61621366 65.11059316 kpa

Diff pressure 4.509226383 6.731405132 m

head 11.41204978 13.43737012 m

Page 1
design

pump flow rate 10.04056795 m3/hr


head 18.31487318 m
NPSH 6.902823396 m

Page 2
design

Nre 103895.0812 If Re<2100,f=16/NRe


Re 3000to 50000,f=0.0014+[0.125/Re^(.32)]
Re 50000 to 1*10^6, f= 0.046*Re^(-0.2)

Nre 613057.3248

mm2 actual line length 1.2 m


m2 bend 2 2.528886358 m
m/s valve 1 2.275997722 m
total length 6.00488408 m

R/density x u2 0.003
N/m2
Kpa

1256 mm2 NRE 17502.54582


0.0491 m2 f 0.006518349
0.056803394 m/s
through friction chart R/density x u2 0.0017
f 0.540846981 N/m2
0.000540847 kpa

line actual length 8 m


bends 4 4.8 m
valves 2 1.44 m
14.24 m

Page 3
design

1.791685284 1.057115483
7.449997982

Page 4
actual practical

Pump discharge pressure 1.5 kg/cm2


Pr. At out let of dryer 1 kg/cm2
line length given in prev. sheet

from previous sheet data

developed head 4.563894523 m

Page 5